Launch of EV-PP range - Consilium
Launch of EV-PP range - Consilium
Launch of EV-PP range - Consilium
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
CONSILIUM MARINE AND SAFETY<br />
CMS 1005-02<br />
Technical Bulletin<br />
<strong>Launch</strong> <strong>of</strong> <strong>EV</strong>-<strong>PP</strong> <strong>range</strong><br />
In line with the update <strong>of</strong> the product portfolio for<br />
loop and section units <strong>of</strong> <strong>Consilium</strong> Marine & Safety,<br />
we are now launching the new <strong>EV</strong>-<strong>PP</strong> dual smoke and<br />
heat detector series.<br />
The <strong>EV</strong>-<strong>PP</strong> is a new model <strong>range</strong> within the Evolution<br />
series <strong>of</strong>fering compatibility with below series <strong>of</strong> old<br />
detectors. The unit is fully backwards compatible<br />
and <strong>of</strong>fers a new optical sensor with improved<br />
performance.<br />
Please note that the smoke detectors <strong>of</strong> the <strong>EV</strong>-<br />
<strong>PP</strong> <strong>range</strong> are <strong>of</strong> optical type. This must be considered<br />
when replacing detectors <strong>of</strong> ionization type, as the<br />
surrounding environment (air flow, humidity etc.) may<br />
Old<br />
Part No<br />
Old<br />
Product<br />
New<br />
Part No<br />
New Product Function<br />
make it necessary to move or protect the location <strong>of</strong><br />
the new detector. Also the contamination time can be<br />
different compared to the old type <strong>of</strong> detector.<br />
The <strong>EV</strong>-<strong>PP</strong> can be easily re-configured from<br />
one model to another by a simple standard base, a<br />
standard test tool SE3000+ and a PC with special<br />
s<strong>of</strong>tware (provided by <strong>Consilium</strong> Marine & Safety).<br />
As the re-configuration is very simple, it is possible<br />
to do in the field.<br />
The <strong>EV</strong>-<strong>PP</strong> <strong>range</strong> can replace the following detectors<br />
(below). Consequently, the replaced detectors will go<br />
into a Last Time Buy process.<br />
047150 TDT-2 040207 <strong>EV</strong>-<strong>PP</strong> / TDT 57 Heat detector 57C IP22<br />
047151 TDT-2 040208 <strong>EV</strong>-<strong>PP</strong> / TDT 80 Heat detector 80C IP22<br />
047152 TDT-2 040209 <strong>EV</strong>-<strong>PP</strong> / TDT 57 RoR Heat detector 57C RoR IP22<br />
047153 TDT-2 040210 <strong>EV</strong>-<strong>PP</strong> / TDT 80 RoR Heat detector 80C RoR IP22<br />
044580 RDO-2 040201 <strong>EV</strong>-<strong>PP</strong> / RDO / OA100 Optical smoke detector IP22<br />
044560 RDJ-2 040202 <strong>EV</strong>-<strong>PP</strong> / RDJ Ionisation smoke detector IP22<br />
044570 RDJ-2T 040203<br />
<strong>EV</strong>-<strong>PP</strong> / IA1302T /<br />
RDJ2T<br />
044500 SID-38 040211 <strong>EV</strong>-<strong>PP</strong> / SID38<br />
044510 SID-38T 040212 <strong>EV</strong>-<strong>PP</strong> / SID38T<br />
Dual optical smoke heat detector 57C IP22 +<br />
subloop<br />
Ionisation smoke detector 57C IP55<br />
(incl base as a kit)<br />
Dual ionisation smoke heat detector 57C IP55 (incl<br />
base as a kit)<br />
044760 OA100 040201 <strong>EV</strong>-<strong>PP</strong> / RDO / OA100 Optical smoke detector IP22<br />
044762 OA120 040204 <strong>EV</strong>-<strong>PP</strong> / OA120 Dual optical smoke heat detector 57C IP22<br />
044763 OA130 040200 <strong>EV</strong>-<strong>PP</strong> / OA130<br />
Dual optical smoke heat detector 57C IP22 +<br />
subloop<br />
044750 IA100 040202 <strong>EV</strong>-<strong>PP</strong> / IA100 Ionisation smoke detector IP22<br />
044752 IA120 040205 <strong>EV</strong>-<strong>PP</strong> / IA120 Dual ionisation smoke heat detector 57C IP22<br />
044753 IA130 040206 <strong>EV</strong>-<strong>PP</strong> / IA130<br />
044755 IA130-2T 040203<br />
<strong>EV</strong>-<strong>PP</strong> / IA1302T /<br />
RDJ2T<br />
Dual ionisation smoke heat detector 57C IP22 +<br />
subloop output<br />
Dual ionisation smoke heat detector 57C IP22 +<br />
subloop output
CONSILIUM MARINE AND SAFETY<br />
<strong>Launch</strong> <strong>of</strong> MCP-C (Conventional Manual Call Points)<br />
A new <strong>range</strong> <strong>of</strong> conventional manual call point is<br />
now introduced to the market. The MCP-C <strong>range</strong><br />
is compatible with the systems CS4000, C300,<br />
C303,C308, C316 and Salwico Cargo, Salwico Cruise<br />
and Salwico Ro/PAX.<br />
Old<br />
Part No<br />
N1301<br />
Old<br />
Product<br />
Salwico<br />
NS-CP<br />
New Part<br />
No<br />
New Product Function<br />
5200010-01A MCP-C IP24 GB Conventional Manual Call Point for Dry Spaces<br />
1270240 KR-1 5200010-01A MCP-C IP24 GB Conventional Manual Call Point for Dry Spaces<br />
--- --- 5200012-01A MCP-C IP24 OEM Conventional Manual Call Point for Dry Spaces<br />
N1305<br />
N1302<br />
NS-CP<br />
(IP55)<br />
NS-CPWP<br />
(IP67)<br />
5200014-01A MCP-C IP67 GB Conventional Manual Call Point for Wett Spaces<br />
5200014-01A MCP-C IP67 GB Conventional Manual Call Point for Wett Spaces<br />
1270241 KSR-1 5200014-01A MCP-C IP67 GB Conventional Manual Call Point for Wett Spaces<br />
--- --- 5200015-01A MCP-C IP67 OEM Conventional Manual Call Point for Wett Spaces<br />
620-001000<br />
LKC05<br />
IP55<br />
5200016-01A<br />
MCP-SPR-C IP67<br />
GB<br />
They are <strong>of</strong> two different IP classes (IP24 and IP67) and<br />
shall be delivered in the following versions compatible<br />
with below listed series <strong>of</strong> old MCP units.<br />
The replaced MCP Units will consequently go into a<br />
Last Time Buy process<br />
Conventional Manual Call Point for Sprinkler<br />
Relece for Wett Spaces<br />
<strong>Launch</strong> <strong>of</strong> MCP-A and SCI-A<br />
(Addressable Manual Call Points and Addressable Short Circuit Isolator)<br />
A new <strong>range</strong> <strong>of</strong> Addressable manual call point and<br />
Short circuit isolator is now introduced to the market.<br />
The MCP-A is compatible with the systems CS4000,<br />
CS3000, CS3004 and and Salwico Cargo, Salwico<br />
Cruise and Salwico Ro/PAX.
CONSILIUM MARINE AND SAFETY<br />
Important Notice!<br />
MCP-A with SCI functionality can only be used at<br />
fire alarm system with appropriate firmware (today<br />
Salwico CS4000and Salwico Cargo, Salwico Cruise and<br />
Salwico Ro/PAX. On all other fire detection systems<br />
these units will only work as an ordinary manual call<br />
point (as a LK-2).<br />
Old<br />
Part No<br />
045160<br />
011351<br />
N11301<br />
011355<br />
N11305<br />
045165<br />
N11303<br />
011352<br />
Old Product New Part<br />
No<br />
LKA 01 MAN CALL<br />
POINT IP24 GB<br />
NS-ACP ANALOG.<br />
CALL POINT IP24D<br />
NS-ACP MANUAL<br />
CALL POINT IP24D<br />
NS-ACP ANA<br />
LOGUE CALL<br />
POINT IP55<br />
NS-ACP-IP55<br />
MANUAL CALL<br />
POINT<br />
LKA 02 MAN CALL<br />
POINT GB IP55<br />
NS-ACPWP MAN<br />
CALL POINT IP67<br />
NS-ACP-WP ANA-<br />
LOG.CALL P. IP67<br />
5200030-01A MCP-A IP23 GB<br />
5200030-01A * MCP-A IP23 GB<br />
5200030-01A * MCP-A IP23 GB<br />
5200031-01A * MCP-A IP67 GB<br />
5200031-01A * MCP-A IP67 GB<br />
5200031-01A MCP-A IP67 GB<br />
5200031-01A * MCP-A IP67 GB<br />
5200031-01A * MCP-A IP67 GB<br />
For that reason Units Marked with * will in a future be<br />
available as a spare part only.<br />
The MCP-A exists in two different IP classes (IP23<br />
and IP67) and the SCI-A in IP67 class. These shall be<br />
delivered in the following versions compatible with<br />
below listed series <strong>of</strong> old MCP and SCI units.<br />
New Product Function<br />
--- --- 5200036-01A MCP-A IP67 OEM<br />
045173<br />
045174<br />
N11311<br />
N11315<br />
LKA 04 MAN C<br />
POINT SPRNK IP67<br />
LKA 05 MAN C<br />
POINT SPRNK IP55<br />
NS-ACP IP22 MCP<br />
WHITE STILL<br />
NS-ACP-IP55 MCP<br />
WHITE STILL<br />
5200037-01A MCP-SPR-A IP67 GB<br />
5200037-01A MCP-SPR-A IP67 GB<br />
5200038-01A * MCP-ST-A IP67 GB<br />
5200038-01A * MCP-ST-A IP67 GB<br />
Addressable Manual Call Point for<br />
Dry Spaces<br />
Addressable Manual Call Point for<br />
Dry Spaces<br />
Addressable Manual Call Point for<br />
Dry Spaces<br />
Addressable Manual Call Point for<br />
Wet Spaces<br />
Addressable Manual Call Point for<br />
Wet Spaces<br />
Addressable Manual Call Point for<br />
Wet Spaces<br />
Addressable Manual Call Point for<br />
Wet Spaces<br />
Addressable Manual Call Point for<br />
Wet Spaces<br />
Addressable Manual Call Point for<br />
Wet Spaces<br />
Addressable Manual Call Point for<br />
Sprinkler release for Wet Spaces<br />
Addressable Manual Call Point for<br />
Sprinkler release for Wet Spaces<br />
Addressable Manual Call Point for<br />
Sprinkler release for Wet Spaces<br />
Addressable Manual Call Point for<br />
Sprinkler release for Wet Spaces<br />
046200 KS-2 5200120-00A SCI-A IP67 Addressable Short Circuit Isolator<br />
046249 KS-2K 5200120-00A SCI-A IP67 Addressable Short Circuit Isolator<br />
N11891 NS-SCI 5200120-00A * SCI-A IP67 Addressable Short Circuit Isolator<br />
The MCP-A is cer tified according to EN54-11, EN54-17, the SCI-A is cer tified according to EN54-17.<br />
MED and CPD is pending (Expected in April 2010).<br />
Salwico Exhaust Emissions Monitoring System is now MED Certified<br />
Salwico Exhaust Emissions Monitoring System has received a marine equipment directive 96/98/EC Examination<br />
Certificate as on-board NOx monitoring and recording devices.
CONSILIUM MARINE AND SAFETY<br />
After Sales information regarding portable detectors from Draeger<br />
The last couple <strong>of</strong> years <strong>Consilium</strong> have sold portable<br />
detectors from Draeger to several new buildings in<br />
mainly China. The main reason for this is to meet the<br />
technical specification from customers. <strong>Consilium</strong><br />
is not marketing as a supplier <strong>of</strong> Draeger portable<br />
detectors.<br />
However, since we are the supplier <strong>of</strong> the equipment<br />
to the shipyard, our responsibility runs during the<br />
New S<strong>of</strong>tware releases:<br />
warranty time. Warranty only covers failure <strong>of</strong> the<br />
portable detector but not recalibration.<br />
When you receive warranty claims, replace the<br />
product with a new and make sure to return the faulty<br />
one to <strong>Consilium</strong> with a RMA number as soon as<br />
possible.<br />
When you receive inquiries for recalibration, refer<br />
directly to a Draeger’s branch <strong>of</strong>fice<br />
New Salwico CS3000 SPK S<strong>of</strong>tware version (SP3P_NFS v2.92)<br />
New s<strong>of</strong>tware version and document is released for the SPK (Loop card), CS3000 v4 and v6.<br />
Part no. 42100.<br />
Improvements:<br />
Start-up concerning <strong>EV</strong>/NS detectors.<br />
Removed 15min inhibit <strong>of</strong> OA-130 after boot.<br />
Unit data listing / printout.<br />
New Salwico CS3000 IBI Modbus S<strong>of</strong>tware version (ibi_6.11<br />
New s<strong>of</strong>tware version and document is released for IBI MODBUS used with CS3000 v6.<br />
Part no. for IBI basic hardware is 041330.<br />
Improvements:<br />
Alarm, Fault and Disconnection lists in IBI are now synchronized at SW2020 reboot<br />
New program version is released for <strong>Consilium</strong> Comtester version 2.0.1.23<br />
New program version is released for <strong>Consilium</strong> Comtester is released<br />
Improvements:<br />
Supports ModBUS Function Code 8<br />
Support to generate ModBUS Matrix file<br />
New Salwico SE3000+ S<strong>of</strong>tware version (se3000p_1.23)<br />
New s<strong>of</strong>tware version and document is released for <strong>Consilium</strong> SE3000+, part no. 047480.<br />
Improvements:<br />
SE3000 Now supports Salwico OA-130<br />
Salwico CS4000 Date non conformity<br />
PC wizard, that is going to make updates available for maintenance personal, is now <strong>of</strong>ficially released. PC Wizard<br />
is released for upgrade <strong>of</strong> following firmware versions:<br />
v1.0.20, v1.0.38, v1.0.39, v1.0.41, v1.1.0, v1.1.1, v1.1.2.<br />
Extremely important!!<br />
Use consequent version <strong>of</strong> the new firmware to one previously installed on a Base Board.<br />
(Ex. BBP v.1.0.20 is only to be upgraded to BBP v.1.0.20, etc.)
CONSILIUM MARINE AND SAFETY<br />
New and updated information in the <strong>Consilium</strong> Document Database:<br />
Part No Product New Updated<br />
1170 SWM-1KL-IS x<br />
1181 SWM-1KL-IS-R x<br />
3112 KVD-Ex x<br />
17213 SM13 x<br />
23114 CN-PS x<br />
23261 CN-AIOI x<br />
38010 HC 100 A2-IS x<br />
40000 <strong>EV</strong>-H x<br />
40005 <strong>EV</strong>-H CS<br />
40050 <strong>EV</strong>-DPH x<br />
40200 <strong>EV</strong>-<strong>PP</strong>/OA130 x<br />
40201 <strong>EV</strong>-<strong>PP</strong>/RDO2/OA100 x<br />
40204 <strong>EV</strong>-<strong>PP</strong>/OA120 x<br />
40211 <strong>EV</strong>-<strong>PP</strong>/SID38 x<br />
40212 <strong>EV</strong>-<strong>PP</strong>/SID38T x<br />
465001 CS4000 Configuration program manual x<br />
5100195 Control Repeater Panel M 4.3 x<br />
5100332 Salwico Cruise User Guide E x<br />
5100333 Salwico Cruise Installation Manual E x<br />
5100334 Salwico Cruise Service & Maintenance Manual E x<br />
5100336 Salwico Cruise Quick Guide E x<br />
5101003 Control Panel M 4.3 x<br />
40200 <strong>EV</strong>-<strong>PP</strong> OA130 x<br />
40201 <strong>EV</strong>-<strong>PP</strong> RDO2 OA100 x<br />
40203 <strong>EV</strong>-<strong>PP</strong>/IA130-2T/RDJ-2T x<br />
40204 <strong>EV</strong>-<strong>PP</strong> OA120 x<br />
40211 <strong>EV</strong>-<strong>PP</strong> SID38 x<br />
40212 <strong>EV</strong>-<strong>PP</strong> SID38T x<br />
462001 BB base board x<br />
462005 RB rectifier board x<br />
5100002-01A Control M X H x<br />
5100026-01B Loop M X H x<br />
5100054-01A BusCon M 20 H x<br />
5100056-01A BusCon M 10 H x<br />
5100062-01A Charger M H x<br />
5100066-01A Change Over M X H x<br />
5100071-01A Bus Isolator M H x<br />
5100075-01A I/O M 70 H x<br />
5100077-01A I/O M 700 H x<br />
5100081-01A Relay M 8 H x<br />
5100087-01A PSU M AC/DC 5A x<br />
5100332-02A01 Salwico Cargo Conventional User Guide E x<br />
5100332-01A00 Salwico Cargo User Guide E x<br />
5100332-02A01 Salwico Cargo Conventional User Guide E x
CONSILIUM MARINE AND SAFETY<br />
Part No Product New Updated<br />
5100333-01A00 Salwico Cargo Installation Manual E x<br />
5100333-02A01 Salwico Cargo Conventional Installation Manual E x<br />
5100334-01A00 Salwico Cargo Service & Maintenance Manual E x<br />
5100334-02A01 Salwico Cargo Conventional Service and Maintenance Manual E x<br />
5100335-00A00 Salwico Cruise Configuration Manual E x<br />
5100335-01A00 Salwico Cargo Configuration Manual E x<br />
5100335-02A01 Salwico Cargo Conventional Configuration Manual E x<br />
5100336-01A00 Salwico Cargo Quick Guide E x<br />
5100336-02A01 Salwico Cargo Conventional Quick Guide E x<br />
5100364-00A01 G1000 Smoke density Monitor x<br />
5100365-00A01 G2000 Ambient Oil Mist Detector x<br />
5100366-00A01 G3500i Inert Gas Oxygen Analyzer x<br />
51400 S<strong>of</strong>t mimic x<br />
5200010-01A MCP-C x<br />
5200016-01A MCP-SPR-C x<br />
5200031-01A MCP-A x<br />
5200038-01A MCP-ST-A x<br />
5200039-00A <strong>EV</strong>C-IR x<br />
5200047-00A A2-IS IP67 x<br />
5200065-00A <strong>EV</strong>-PS x<br />
5200087-00A Mini printer x<br />
5200097-00A <strong>EV</strong>-BI x<br />
5200098-00A <strong>EV</strong>-SPB-BI x<br />
5200112-00A Testifire x<br />
5200120-00A SCI-A x<br />
5200123-00A <strong>EV</strong>-AD2 x<br />
60060-001010 ACP-IS x<br />
N1123 NS-DIR IP67 x<br />
N11250 NS-AOHS-IS x<br />
N11255 AOHS-Exn x<br />
N1126 NS-DIR IP67 x<br />
N11320 ACPWP-Exn x<br />
N11321 ACP-IP55-Exn x<br />
N1144 <strong>EV</strong>C-PY-IS x<br />
N11890 SCI-Exn x<br />
S-4-013.302 NMEA CCP Protocol description x<br />
<strong>Consilium</strong> Marine & Safety AB<br />
Fire & Gas Marine Division<br />
Salsmästaregatan 21<br />
P.O.Box 8763<br />
SE-402 76 Gothenburg<br />
Sweden<br />
Phone: +46 31 710 77 00<br />
Fax: +46 31 710 78 00