<strong>TrilliumSeries</strong> Condenser<br />
TABLE OF CONTENTS<br />
1 <strong>TrilliumSeries</strong> Condenser<br />
3 BENEFITS<br />
7 MODES OF OPERATION<br />
8 EcoFlex Controls<br />
9 REBATE MAP<br />
10 ENGINEERING DATA
The <strong>TrilliumSeries</strong> Condenser<br />
The <strong>TrilliumSeries</strong> Condenser uses a patented Dry-Coil Adiabatic Design that saves<br />
energy, reduces refrigerant charge, and lowers operating costs. With the use of proprietary<br />
logic and sophisticated controls, the On-Demand Adiabatic Pre-Cooler uses water only<br />
on the hottest days to maintain condensing temperatures that typical air cooled technology<br />
can’t achieve.<br />
››<br />
High Efficiency, Whisper Quiet<br />
Fan System<br />
``<br />
Latest noise reducing technology<br />
`<br />
` High efficiency electronically commutated (EC)<br />
motors<br />
``<br />
Internal variable fan speed control<br />
››<br />
Robust Microchannel Technology<br />
``<br />
40% higher thermal efficiency<br />
``<br />
30% smaller face area<br />
`<br />
` Unique top feed design with vertical tubes allowing<br />
for gravity drainage of the condensed refrigerant that<br />
also eliminates the need for external manifolding<br />
››<br />
On-Demand Adiabatic Pre-Cooler<br />
``<br />
Drastically lowers air temperature to heat exchanger<br />
``<br />
Increases temperature difference, driving additional<br />
heat rejection<br />
``<br />
Increases unit efficiency by up to 40%<br />
››<br />
EcoFlex Control System<br />
``<br />
Optimizes unit performance and reduces energy use<br />
``<br />
Eliminates the need for water treatment<br />
``<br />
Ships pre-programmed, ready for use<br />
1 QUESTIONS? CALL 410.799.6200 OR VISIT WWW.BALTIMOREAIRCOIL.COM
››<br />
High Thermal Performance<br />
``<br />
Lower Total Cost of Ownership<br />
``<br />
Reduced Compressor Work<br />
``<br />
High Efficiency EC Motors<br />
``<br />
Variable Fan Speed Control<br />
`<br />
` Air Pre-cooling to Temperatures<br />
Approaching Wet-bulb Temperature<br />
››<br />
Environmentally Friendly<br />
``<br />
Smaller Refrigeration System<br />
`<br />
``<br />
60% Less Refrigerant Charge<br />
` Up to 18% Peak Energy Reduction<br />
››<br />
Water Saving<br />
``<br />
No Water Treatment<br />
``<br />
Minimal Water Use<br />
``<br />
Intelligent Controls<br />
PRODUCT MANUAL: <strong>TrilliumSeries</strong> Condenser 2
Benefits<br />
››<br />
Ownership Benefits<br />
In a variety of climate conditions, the <strong>TrilliumSeries</strong> Condenser provides the lowest total cost of ownership compared to air<br />
cooled units.<br />
``<br />
INSTALLATION ADVANTAGES<br />
• 60% lower refrigerant charge<br />
• Compact<br />
• Single point electrical connection<br />
• Direct drive EC motors and Whisper Quiet Fans are standard<br />
• Reduces overall system size<br />
``<br />
ECONOMICAL ADVANTAGES<br />
• Attractive payback timeframes<br />
• Lower total cost of ownership<br />
1.4<br />
1.2<br />
1.0<br />
<strong>TrilliumSeries</strong> Condenser Payback<br />
(See Notes 1,2,3)<br />
Years<br />
0.8<br />
0.6<br />
0.4<br />
0.2<br />
0.0<br />
Boston 5 Atlanta 5 Chicago 5 Phoenix 4,5 Los Angeles 4,5<br />
Notes for the <strong>TrilliumSeries</strong> Condenser Payback Chart:<br />
1. California Title 24 pricing equation for air cooled condensers.<br />
2. California Title 24 2013, effective on 1-1-2014, states all condensers must have VFDs to control fan motors.<br />
3. Condensing temperature for air cooled is set at 100-110°F depending on the climate; <strong>TrilliumSeries</strong> Condenser is set at 95°F.<br />
4. In Phoenix and Los Angeles, the first cost of a <strong>TrilliumSeries</strong> Condenser is lower than the first cost of an air cooled condenser.<br />
5. The cities were selected based on climate conditions.<br />
3 QUESTIONS? CALL 410.799.6200 OR VISIT WWW.BALTIMOREAIRCOIL.COM
››<br />
System Energy Savings<br />
``<br />
Reduces condensing temperatures<br />
``<br />
Less compressor work<br />
`<br />
` Direct drive EC motors match fan speed to load<br />
40,000<br />
35,000<br />
Annual 19.2% System Energy Reduction for Chicago, Illinois<br />
Total kWh<br />
30,000<br />
25,000<br />
20,000<br />
15,000<br />
10,000<br />
5,000<br />
Air Cooled System<br />
Total kWh<br />
<strong>TrilliumSeries</strong><br />
Total kWh<br />
››<br />
Peak Energy Savings<br />
0<br />
-26.5<br />
-18.5<br />
-10.5<br />
``<br />
Up to 18% peak energy reduction compared to air cooled units<br />
-2.5<br />
5.5<br />
13.5<br />
21.5<br />
29.5<br />
• Peak energy is more expensive than off peak energy<br />
• Potential for state, local energy rebates<br />
37.5<br />
45.5<br />
53.5<br />
Dry-Bulb Temperatures (°F)<br />
61.5<br />
Peak Energy Reduction in %<br />
69.5<br />
77.5<br />
85.5<br />
93.5<br />
101.5<br />
6.8%<br />
Boston<br />
12.3%<br />
Atlanta<br />
13.4%<br />
Chicago<br />
18.5%<br />
Phoenix<br />
1.5%<br />
Los Angeles<br />
0 5 10 15 20<br />
PRODUCT MANUAL: <strong>TrilliumSeries</strong> Condenser 4
Benefits<br />
››<br />
On-Demand Adiabatic Pre-Cooler<br />
``<br />
Water is used ONLY when load and ambient temperatures require it<br />
• Water spray saturates and cleans the pads of any dust and debris<br />
``<br />
No water treatment is required<br />
``<br />
Free draining prevents stagnant water<br />
``<br />
Up to 4 LEED ® Points for water efficient landscaping (WE credit 1) based on 2009 LEED for Retail and<br />
Commercial Interior rating system<br />
• Water from the drain and overflow can be used for irrigation or other non-potable uses<br />
Annual Water Use<br />
Typical Evaporative Condenser<br />
100<br />
100<br />
90<br />
90<br />
<strong>TrilliumSeries</strong><br />
Condenser<br />
Noise<br />
Level (dB)<br />
80<br />
70<br />
70<br />
80<br />
Noise Level (dB)<br />
60<br />
60<br />
0 50 100<br />
150 200 250<br />
Water Use (Gallons/Year)<br />
Water Use Compared to Evaporative Condensers<br />
› Low Sound<br />
Sound Levels<br />
›<br />
``<br />
Whisper Quiet Fans are standard<br />
``<br />
Direct drive EC fan motors vary the fan speed eliminating sudden Normal starts Conversation and stops<br />
60<br />
AquaVenta Operating at Full Speed 70<br />
``<br />
Quiet sides can be positioned toward neighbors<br />
Traffic on a busy road 80<br />
Air Cooled Condenser 84<br />
Jack Hammer 100<br />
5 QUESTIONS? CALL 410.799.6200 OR VISIT WWW.BALTIMOREAIRCOIL.COM
››<br />
Easy Maintenance<br />
``<br />
Water treatment is not required<br />
• Water is turned on only when load and outside<br />
temperatures require it<br />
• Water spray saturates and cleans the pads of any dust and<br />
debris<br />
``<br />
Adiabatic pads act as a filter to prevent debris on the<br />
microchannel<br />
• Can be removed without tools for easy coil inspection<br />
``<br />
Clean-out ports on both ends for easy cleaning<br />
``<br />
The EcoFlex Controls maintain a clean sump<br />
``<br />
Pump and valves are easily accessible from the access hatch<br />
Easy Access to Pump and Valves<br />
››<br />
Charge Reduction<br />
``<br />
60% less charge than comparable air cooled condensers<br />
``<br />
Reduced charge could help meet EPA’s Greenchill<br />
commitments<br />
``<br />
Lowers global warming potential of the supermarket<br />
refrigeration system<br />
Refrigerant Charge (lbs.)<br />
250<br />
200<br />
150<br />
100<br />
50<br />
0<br />
Charge Reduction<br />
Unit Refrigerant Charge<br />
Air Cooled<br />
Condenser<br />
<strong>TrilliumSeries</strong><br />
Condenser<br />
››<br />
Peace of Mind<br />
``<br />
All units are equipped with state of the art controls for fan<br />
speed, pre-cooling, and daily automatic sump clean out<br />
``<br />
All critical components are stocked and can be ordered online<br />
with a 24-hour delivery<br />
``<br />
Manual discrete spray system standard<br />
``<br />
Durable materials of construction extend the life of the unit<br />
``<br />
Sump and drain pans drain freely<br />
``<br />
Ability to switch fans from automatic to manual fan override<br />
for loss of a control signal<br />
` ` Manual control reset and interlocked hatch sensor are<br />
standard<br />
Discrete Spray System<br />
PRODUCT MANUAL: <strong>TrilliumSeries</strong> Condenser 6
Modes of Operation<br />
››<br />
Dry Mode<br />
The ambient air at the dry bulb temperature passes through<br />
the pads and then over the microchannels. The ambient air<br />
condenses the refrigerant in the microchannel coils which is<br />
then returned to the evaporators.<br />
Adiabatic<br />
Pads<br />
Vapor In<br />
Warm Air Out<br />
Microchannel<br />
Coils<br />
Vapor In<br />
Adiabatic<br />
Pads<br />
››<br />
On-Demand Adiabatic<br />
Pre-Cooler Mode<br />
Air in at<br />
Dry-Bulb<br />
Temp<br />
Air in at<br />
Dry-Bulb<br />
Temp<br />
On days when the load is high and the ambient air<br />
temperature is high the unit will run in On-Demand<br />
Adiabatic Pre-Cooler Mode. Water is evenly sprayed over<br />
highly efficient cooling pads. As the air passes through<br />
the pads, water is evaporated in to the air, and the air is<br />
humidified, cooling temperatures down to 2-3 ºF above<br />
wet-bulb temperature. Such substantial depression of the dry<br />
bulb temperature results in a major increase in dry cooling<br />
capacity.<br />
Dry Mode Operation<br />
Liquid Out<br />
Warm Air Out<br />
Liquid Out<br />
The cooler air passes over the microchannel and condenses<br />
the refrigerant in the microchannel which is then returned to<br />
the compressor. In the sump there is an industrial duty pump<br />
that recirculates the water. The EcoFlex Controls determine<br />
when the water is purged from the sump. Part of the<br />
distributed water is evaporated, while the excess water assists<br />
in rinsing the pad to keep it free from debris and minerals that<br />
would otherwise stay behind on the pad after evaporation.<br />
Water<br />
Distribution<br />
System<br />
Adiabatic<br />
Pads<br />
Air in at<br />
Dry-Bulb<br />
Temp<br />
Vapor In<br />
Microchannel<br />
Coils<br />
Vapor In<br />
Water<br />
Distribution<br />
System<br />
Adiabatic<br />
Pads<br />
Air in at<br />
Dry-Bulb<br />
Temp<br />
Air<br />
Cooled<br />
to 2ºF<br />
of Wet-<br />
Bulb<br />
Temp<br />
Air<br />
Cooled<br />
to 2ºF<br />
of Wet-<br />
Bulb<br />
Temp<br />
Liquid Out<br />
Pump<br />
Liquid Out<br />
On-Demand Adiabatic Pre-Cooler Mode<br />
7 QUESTIONS? CALL 410.799.6200 OR VISIT WWW.BALTIMOREAIRCOIL.COM
EcoFlex Controls<br />
The <strong>TrilliumSeries</strong> Condenser is furnished standard with state of the art controls that<br />
provide efficient year round performance. Each unit is shipped with custom controls logic<br />
that reduces energy consumption and optimizes water usage. With preset controls, the<br />
system is programmed and ready to operate upon arrival from the factory.<br />
YES<br />
Ambient<br />
Temperature =<br />
Set Point<br />
NO<br />
Pre-Cool Mode<br />
ON<br />
Pre-Cool Mode<br />
OFF<br />
Vary Fan Speed based on<br />
0-10V signal<br />
Vary Fan Speed based on<br />
0-10V signal<br />
Start Pump Sequence with<br />
Water Hardness Controls<br />
Continue Sensing<br />
Ambient Dry-bulb<br />
Temperature<br />
PRODUCT MANUAL: <strong>TrilliumSeries</strong> Condenser 8
Rebate Map<br />
Potential rebates are available for decreased energy use. These opportunities are highlighted<br />
in blue on the map above. As illustrated, a majority of states offer utility incentives and rebates<br />
which further decrease the initial investment of the <strong>TrilliumSeries</strong> Condenser.<br />
There are various types of rebates available for energy savings and are dependent on utility regulations.<br />
Type of Rebate Utility Details<br />
Custom<br />
Refrigeration<br />
VFDs on Fan Motors or<br />
Other Controls<br />
Arizona<br />
APS<br />
California<br />
Pacific Gas and Electric (PG&E)<br />
California<br />
SCE-Non-Residential Energy Efficiency<br />
Programs<br />
Custom Measures and Retro-commissioning:<br />
$0.11/ kWh saved up to 75% of incremental cost<br />
• Refrigeration Equipment: $35-$1000/unit<br />
• Air Conditioning and Refrigeration: $0.09 - $0.15/kWh<br />
saved<br />
• Variable Frequency Drives: $80/HP<br />
• Refrigeration Controls: $75-$100/Controller<br />
The above are examples based on information from dsireusa.org. Dsireusa.org is a website with information on state,<br />
local, utility, and federal incentives and policies that promote renewable energy and energy efficiency. Established in<br />
1995 and funded by the U.S. Department of Energy, DSIRE is an ongoing project of the N.C. Solar Center and the<br />
Interstate Renewable Energy Council.<br />
For custom rebates, an analysis of the overall system energy savings from air-cooled to the <strong>TrilliumSeries</strong> Condenser<br />
maybe necessary. This analysis is available from Baltimore Aircoil Company along with any application support.<br />
9 QUESTIONS? CALL 410.799.6200 OR VISIT WWW.BALTIMOREAIRCOIL.COM
Engineering Data<br />
NOTE: Do not use for construction. Refer to factory certified dimensions. This catalog includes data current at the time of publication,<br />
which should be reconfirmed at the time of purchase. Up-to-date engineering data, and more can be found at www.BaltimoreAircoil.com.<br />
2'-11 1/4"<br />
1 1/8" Refrigerant In<br />
3/4" GHT Discrete Spray<br />
(Garden Hose Thread)<br />
5'-2 1/2"<br />
3'-10 1/2"<br />
5'-3 1/4"<br />
1 1/8" Refrigerant<br />
Out<br />
2'-2 3/4"<br />
4'-2"<br />
6’- 0 5/8"<br />
6'-11 7/8"<br />
8"<br />
L<br />
Model<br />
Fan<br />
Qty<br />
Base Heat<br />
Rejection<br />
(MBH)<br />
Base<br />
Tons<br />
Motor<br />
HP<br />
Pump<br />
HP<br />
Airflow<br />
(CFM)<br />
Unit Length<br />
Total (in)<br />
(L)<br />
Shipping<br />
Weight<br />
(lbs)<br />
Operating<br />
Weight<br />
(lbs)<br />
TSDC-033-3 1 386 33 3 0.25 14,890 5'-10 7/8" 1,280 1,450<br />
TSDC-058-6.2 2 692 58 6.2 0.25 28,000 8'-6 7/8" 1,740 1,940<br />
TSDC-085-9.6 3 1011 85 9.6 0.25 41,400 11'-8 3/4" 2,300 2,530<br />
Note: Base Heat Rejection (MBH) is based on R-134a 95°F Dry-Bulb/76°F Wet-Bulb and 105°F Condensing<br />
Temperature<br />
PRODUCT MANUAL: <strong>TrilliumSeries</strong> Condenser 10
COOLING TOWERS<br />
CLOSED CIRCUIT COOLING TOWERS<br />
ICE THERMAL STORAGE<br />
EVAPORATIVE CONDENSERS<br />
HYBRID PRODUCTS<br />
PARTS & SERVICES<br />
www.BaltimoreAircoil.com<br />
7600 Dorsey Run Road, Jessup, MD 20794 › Telephone: (410) 799-6200 › Fax: (410) 799-6416<br />
© 2012 Baltimore Aircoil Company › S410/1-A<br />
11 QUESTIONS? CALL 410.799.6200 OR VISIT WWW.BALTIMOREAIRCOIL.COM