to<br />

no s<strong>of</strong>tening<br />

writer's criterion<br />

experimental<br />

failure load —<br />

modified Coulomb criterion<br />

experimental data<br />

2 3 4 5<br />

CENTRE DEFORMATION 6lmml<br />

Fig. 5.2-9: Experimental and calculated centre deflections.<br />

criterion (1977) is used again. In fact, the calculations were<br />

stopped at p = 49.1 MPa without impending failure and it emphasizes<br />

the importance <strong>of</strong> inclusion <strong>of</strong> a realistic post-failure<br />

behaviour in a constitutive model. This requirement is obviously<br />

more pertinent the more inhomogeneously the structure is<br />

loaded as stress redistribution then becomes essential. This<br />

effect is illustrated in fig. 10, where the contour lines for<br />

the nonlinearity index in per cent at p = 49.1 MPa are shown for<br />

the case <strong>of</strong> no-s<strong>of</strong>tening. A comparison with fig. 8c) demonstrates<br />

clearly the structural mechanism related to the assumpno-s<strong>of</strong>tening.<br />

p = 49.1 MPa<br />

Fig. 5.2-10: Contour lines for the nonlinearity index<br />

in per cent. Pressure = 49.1 MPa. Nos<strong>of</strong>tening<br />

in the post-failure region is<br />

assumed.