15.06.2014 Views

RESISTRON

RESISTRON

RESISTRON

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Wiring diagram of the RESM-5 (new)<br />

AUTOCAL<br />

with 24VDC signal<br />

5<br />

RESM-5<br />

1<br />

2<br />

1<br />

2<br />

Line filter LF-xx480<br />

LINE<br />

START (HEAT)<br />

with 24VDC signal<br />

6<br />

RESET<br />

with 24VDC signal<br />

7<br />

9, 10,<br />

11 or<br />

12<br />

See RESM-5<br />

documentation<br />

3<br />

4<br />

NC<br />

NC<br />

U1<br />

prim.<br />

GND<br />

Ground<br />

Must be grounded<br />

externally to<br />

prevent electrostatic<br />

charging!<br />

14<br />

GND 13<br />

Auxilary<br />

power supply<br />

+24VDC 12<br />

NC<br />

NC<br />

15<br />

16<br />

7/8<br />

( )<br />

*<br />

8/7<br />

0V<br />

(Internal ground)<br />

NO EXTERNAL<br />

GROUNDIG<br />

ALLOWED!<br />

5<br />

6<br />

8<br />

9<br />

10<br />

11<br />

UR<br />

IR<br />

Impulse<br />

transformer<br />

Twisted<br />

R<br />

Current<br />

transformer<br />

PEX-W2/-W3<br />

U2<br />

sec.<br />

Heatsealing<br />

band<br />

ANALOG<br />

OUTPUT<br />

(actual value)<br />

+0...10VDC<br />

ALARM<br />

OUTPUT<br />

+24VDC<br />

17<br />

18<br />

13, 14<br />

or<br />

15<br />

See RESM-5<br />

documentation<br />

*<br />

Note: ( )<br />

If error code 118 appears when<br />

you switch on the RESM-5,<br />

these cables should be<br />

reversed/interchanged.<br />

X<br />

Terminals<br />

on RESM-4<br />

RESM-4/RESM-5 Replacement Page 7