ELECTRICAL AND MECHANICAL<br />
ENGINEERING REGULATIONS<br />
(By Command of the Defence Council)<br />
RESTRICTED<br />
TELECOMMUNICATIONS<br />
K 010<br />
CONDITIONS<br />
OF RELEASE<br />
(To be applied to documents which Ihe recipient Government may n<strong>ot</strong> release<br />
to anyone outside its Defence Departments).<br />
a. This inf~>rmation IS relexsetl hy the UK Government to tie recipient<br />
Government for Del’wce purposes only.<br />
b. This information must be accorded the same degree of security pr<strong>ot</strong>ecllon<br />
as that accorded thereto by the UK Governmenl.<br />
c. This Information may be disclosed only wlthin the Defence Departments<br />
of the recipient Government, except as <strong>ot</strong>herwise allthorlzed by Ministry<br />
of Defence (Army).<br />
d. This information may be subject to privately owned rights.<br />
CLANSMANBATTERYCHARGINGEQUIPMENTS<br />
TECHNICAL<br />
HANDBOOK - DATA SUMMARY<br />
NOMENCLATURE<br />
Designation: Charger battery, a.c. Part No: Z9/6130-99-117-0451<br />
Designation: Cha.rger battery, d.c. 28V Part No: Z9/6130-99-117-0450<br />
Designation: Charger battery, d.c. 14V Part No: 6130-99-620-2114<br />
Designation: Generator, electrical, han& operated Part No: Z1/5820-99-114-3390<br />
Fig<br />
1 - General view of equipments<br />
Issue 1. May 72 (17N)<br />
RESTRICTED<br />
Page 1
TELECOMMUNICATIONS RESTRICTED ELECTRICAL AND MECHANICAL<br />
K 010 ENGINEERING REGULATIONS<br />
PURPOSE<br />
The a.c. and d.c. charging units charge she Clansman 24V 3AH nickel cadmium battery associated with the<br />
UK/PRC-320, UK/PRC-351 and UK/PRC-352. The hand generator with a 1AH nickel cadmium battery<br />
powers the UK/PRC-320 and UK/PRC-351 when there are no charging facilities available for the 3AH<br />
batteries.<br />
DESCRIPTION<br />
Charger battery, a.c.<br />
Provides individual outputs to charge up to sixteen Clansman batteries from a.c. mains or on equivalent<br />
generator supply. Each output has a temperature sensing circuit, voltage and current regulation, and<br />
lamps to indicate the correct charging and the fully charged conditions. Sixteen battery charging leads.<br />
a mains lead and spare fuses are stowed in the lid of the carrying case. The equipment is NOT hermetically<br />
sealed.<br />
Charger battery, d.c. 28V<br />
A hermetically sealed d.c. to d.c. converter with voltage and current regulation designed to float charge<br />
a single Clansman battery from a 28V d.c. FFR vehicle supply. The input circuit is n<strong>ot</strong> earthed enabling<br />
the equipment to be used with positive or negative earthed returns. The equipment may also be used for<br />
charging the battery in isolation from the radio. Simple lamp indication operated by a temperature sensing<br />
circuit shows correct charging and fully charged conditions.<br />
Charger battery, d.c. 14V<br />
As for the d.c. 28V model but designed for use with the 12V d.c. supply of a GS vehicle.<br />
Generator electrical,<br />
hand operated<br />
A hermetically sealed 24V d.c. generator used with a clipped on, float charged, 24V 1AH nickel cadmium<br />
battery to replace the 24V 3AH battery. Charge is maintained by hand cranking the generator, correct<br />
charging speed is indicated by the front panel light being extinguished. Under normal conditions of use<br />
the generator output is insufficient to maintain full charge in a 3AH radio battery. In an emergency the<br />
generator may be used without a battery to operate the RECEIVER ONLY.<br />
PHYSICAL<br />
DATA<br />
Height<br />
Depth<br />
Width<br />
Weight<br />
Charger battery, a.c.:<br />
12.25 in. 13.75 in.<br />
(310 mm) (350 mm)<br />
17.25 in.<br />
(430 mm)<br />
65 lb<br />
(30 kg)<br />
Charger battery d.c. 28V )<br />
Charger battery d.c. 14V )<br />
5.65 in. 4.65 in.<br />
(145 mm) (120 mm)<br />
8.2 in.<br />
(210 mm)<br />
5 lb<br />
(2.25 kg)<br />
Generator electrical hand<br />
operated (with 1AH battery)<br />
6.25 in. 7.75 in.<br />
(160 mm) (200 mm)<br />
3.25 in.<br />
(85 mm)<br />
8 lb<br />
(3.6 kg)<br />
CLIMATIC<br />
RANGE<br />
Operational:<br />
Storage:<br />
-370C to +52oC<br />
-4OOC to +65OC<br />
May be used and stored up to 8,000 ft.<br />
page 2 RESTRICTED Issue 1, May 72
ELECTRICAL AND MECHANICAL RESTRICTED TELECOMMUNICATIONS<br />
ENGINEERING REGULATIONS K 010<br />
Humidity (operat,ional and storage)<br />
95 to 100% with temperatures n<strong>ot</strong> normally exceeding 300C<br />
TRANSPORTATION<br />
DATA<br />
May be transport.ed up to 25,000 ft under normal conditions.<br />
PACKAGING<br />
DATA<br />
Packed in accordance with DEF 1234A<br />
Charger battery, a.c.:<br />
Charger battery, d.c. 28V:<br />
SPIS SRDE1612<br />
Charger battery, d.c. 14V:<br />
Generator electrical, hand operated: SPIS SRDE1615<br />
ELECTRICAL<br />
DATA<br />
Or1tput<br />
Voltage<br />
Output<br />
Current<br />
input Input No of<br />
Voltage Current Outputs<br />
Charger battery, a.c.:<br />
3ov-32v<br />
l.lA-1.5A<br />
lOOV-120V 6% 6A (max) 16<br />
2OOV-250V z!6%<br />
at 50-60Hz<br />
Charger battery, d.c. 28V:<br />
3OV-32\i<br />
l.lA-1.5A<br />
2OV-30V DC 3.4A(max) 1<br />
Charger battery, d.c. 14V:<br />
3OV-32V<br />
l.lA-1.5A<br />
lOV-16V DC 6A (max) 1<br />
Generator electrical<br />
hand operat.ed:<br />
3ov-32v<br />
300mA<br />
- - 1<br />
ASSOCIATED<br />
EQUIPMENT<br />
Designation:<br />
Battery, secondary nickel cadmium 24V 3AH<br />
Part No:<br />
Designation:<br />
Battery, secondary nickel cadmium 24V 1AH<br />
Part No:<br />
For use with the Generator electrical,<br />
hand operated.<br />
MAINTENANCE<br />
Charger battery, a.c.<br />
Unit Repairs:<br />
Replacement of front panel mounted components and loose CES items.<br />
Field Repairs:<br />
Replacement of assemblies,<br />
and discrete components.<br />
Base Repairs:<br />
Repair of unserviceable<br />
CENTREMs.<br />
Issue 1, May 72 RESTRICTED Page 3
TELECOMMUNICATIONS RESTRICTED ELECTRICAL AND MECHANICAL<br />
K 010 ENGINEER!NG REGULATIONS<br />
Charger battery d.c. 2SV/14V and generator electrical,<br />
hand operated<br />
Unit Repairs:<br />
Exchange of loose CES items.<br />
Field Repairs: Replacement of assemblies, sub-assemblies and discrete components,<br />
Base Repairs: Repair of unserviceable CENTREMs.<br />
EME/8c/3916<br />
ii /Tels<br />
END<br />
Page 4 RESTRICTED Issut: 1, May 72