<strong>Wellbore</strong> <strong>Quality</strong> Scorecard – Guidel<strong>in</strong>es<br />

<strong>Drill<strong>in</strong>g</strong> Response (5 po<strong>in</strong>ts)<br />

Severe drill<strong>in</strong>g problems<br />

- stuck pipe<br />

- near stuck pipe <strong>in</strong>cident<br />

Score<br />

Transient drill<strong>in</strong>g problems<br />

- poor hole clean<strong>in</strong>g with high cutt<strong>in</strong>gs bed<br />

2<br />

- severe pack-off<br />

2<br />

- severe loss circulation<br />

2<br />

- erratic torque <strong>and</strong> drag response<br />

3<br />

Torque <strong>and</strong> drag response<br />

- all parameters follow smooth trend<br />

- lower than expected torque <strong>and</strong> drag<br />

F<strong>in</strong>al Trip-out Response (7 po<strong>in</strong>ts)<br />

0<br />

1<br />

4<br />

5<br />

Score<br />

Stuck pipe 0<br />

Residual cutt<strong>in</strong>gs bed / differential stick<strong>in</strong>g<br />

- section length with overpulls > 100 klbs<br />

- section length with overpulls > 50 klbs<br />

Ledges<br />

- isolated overpulls > 100 klbs<br />

- isolated overpulls > 50 klbs<br />

1<br />

2<br />

3<br />

4<br />

<strong>Cas<strong>in</strong>g</strong> <strong>Runn<strong>in</strong>g</strong> Response (8 po<strong>in</strong>ts)<br />

Severe cas<strong>in</strong>g runn<strong>in</strong>g problems<br />

- stuck cas<strong>in</strong>g<br />

- cas<strong>in</strong>g pulled due to downhole problems<br />

Score<br />

Differential stick<strong>in</strong>g environment<br />

- static friction > 100 klbs on connections 1<br />

- static friction > 50 klbs on connections 2<br />

Intervention needed dur<strong>in</strong>g cas<strong>in</strong>g run<br />

- unplanned rotation needed<br />

3<br />

- unplanned circulation needed<br />

4<br />

- jo<strong>in</strong>ts wiped to reduce drag 5<br />

<strong>Cas<strong>in</strong>g</strong> run without significant problems<br />

- elevated but smooth drag levels<br />

6<br />

- achieved expected drag levels<br />

7<br />

- better than expected drag levels 8<br />

Transient tripp<strong>in</strong>g-out problems<br />

- loss circulation<br />

5<br />

- unplanned circulation<br />

5<br />

- unplanned ream<strong>in</strong>g <strong>and</strong> back-ream<strong>in</strong>g 5<br />

Drag response<br />

- smooth drag levels measured throughout<br />

- better than expected drag levels recorded<br />

0<br />

0<br />

6<br />

7