2<br />

<strong>Machine</strong> <strong>Edition</strong><br />

<strong>Machine</strong> <strong>Edition</strong> Projects<br />

6. If necessary, configure the I/O hardware connections for your project.<br />

■<br />

For Logic Developer - PC, set up Control I/O in the Control I/O Drivers<br />

folder (in the Project tab of the Navigator). To add a driver, right-click the<br />

Control I/O Drivers folder and select New Driver. Use the Control I/O tool to<br />

configure your drivers. Map variables to I/O terminals.<br />

■<br />

For View, set up PLC Access I/O in the PLC Access Drivers folder. To add a<br />

driver, right-click the PLC Access Drivers folder and select New Driver.<br />

Configure the drivers in the Inspector window. On NT targets, you might want<br />

to set up OPC I/O in the OPC Client folder.<br />

7. When your project is complete; validate, download, and run your project by pressing the F9 function key.<br />

<strong>Machine</strong> <strong>Edition</strong> saves the project, performs a validation, builds the run time files,<br />

and attempts to establish a connection to the target computer.<br />

Validating and Downloading a Project<br />

During project development, you will go through the validation and download<br />

processes several times. The validation process checks the project for errors. If the<br />

project contains errors, they are listed in the Build tab of the Feedback Zone.<br />

■<br />

All errors must be fixed before the download process can proceed. Warnings<br />

are also listed in the Feedback Zone, but they do not prevent the download<br />

from starting.<br />

When fixing project errors, use the F4 function key to scroll through errors in the<br />

Feedback Zone, jumping to their locations in the project.<br />

The download process involves two steps. The first step creates (or builds) all the<br />

run time files necessary for a target to perform its role in a completed project. The<br />

second downloads those files to the target devices or computers.<br />

■<br />

■<br />

Want to know more?<br />

In the Help Index, look up control and choose “Control I/O Tool”.<br />

For Motion Developer, the easiest way to set up the motion control device for<br />

downloading is with the Set Communication Parameters wizard. Open the<br />

Main Wizard page for the target (right-click the target and select Main Wizard).<br />

Then, point to Configuration and select Communication Parameters. Click<br />

Finish when you’re done.<br />

To download a View or Logic Developer - PC project to the Windows NT<br />

computer on which you are developing (a local target), ensure the target<br />

property Computer Address is set to “.” (without the quotation marks).<br />

Otherwise—for remote targets—type the IP address or computer name of the<br />

remote computer you want to download to, in the Computer Address property.<br />