<strong>TM</strong> 3-<strong>4240</strong>-<strong>313</strong>-<strong>10</strong><br />

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).<br />

WARNING<br />

To prevent electrical shock, ensure motor blower power switch is in off (down) position before<br />

connecting or disconnecting power cable.<br />

(16) Remove power cable (22) from accessory package.<br />

(17) Remove connector covers (23) from motor blower (24) connectors J1 (25) and J2 (26).<br />

(18) Connect power cable (22) connector P2 to input connector Jl (25) of motor blower (24).<br />

(19) Connect power cable (22) connector P1 to either the 1<strong>10</strong> VAC cable adapter (27) or 220 VAC cable<br />

adapter (28) depending on power source available.<br />

(20) Connect PE power supply power cord (29) and connect to output connector J2 (26).<br />

(21) Connect cable adapter (27 or 28) to power source.<br />

2-33