FLOOR-CEILING ASSEMBLIES<br />

WITH FORM DECKS<br />

Restrained<br />

Assembly<br />

Rating<br />

Type<br />

<strong>of</strong><br />

Protection<br />

Concrete<br />

Thickness &<br />

Type (1)<br />

U.L.<br />

Design<br />

No. (2,3)<br />

Type <strong>of</strong> Form <strong>Deck</strong><br />

Unrestrained<br />

Beam<br />

Rating<br />

1 Hr.<br />

1 1 /2 Hr.<br />

2 Hr.<br />

3 Hr.<br />

Exposed Grid<br />

Cementitious<br />

Sprayed Fiber<br />

Exposed Grid<br />

Gypsum Board<br />

Cementitious<br />

Sprayed Fiber<br />

Concealed Grid<br />

Exposed Grid<br />

Gypsum Board<br />

Cementitious<br />

Sprayed Fiber<br />

Concealed Grid<br />

Exposed Grid<br />

Gypsum Board<br />

Cementitious<br />

Sprayed Fiber<br />

2 1 /2" NW<br />

2 1 /2" NW&LW<br />

2 3 /4" NW&LW<br />

2 1 /2" NW&LW<br />

2 3 /4" NW&LW<br />

2" NW<br />

2 1 /2" NW<br />

3" NW<br />

2" NW&LW<br />

2 1 /2" NW&LW<br />

2 3 /4" NW&LW<br />

2 1 /2" NW&LW<br />

2 3 /4" NW&LW<br />

2 1 /2" NW<br />

2 1 /2" NW<br />

3" NW<br />

2" NW<br />

2 1 /2" NW&LW<br />

2 1 /2" NW<br />

2 1 /2" NW&LW<br />

2 3 /4" NW&LW<br />

2 1 /2" NW&LW<br />

2 3 /4" NW&LW<br />

3 1 /4" NW<br />

3 1 /2" NW<br />

3 1 /4" NW<br />

3 1 /2" NW<br />

3 1 /4" NW&LW<br />

2 3 /4" NW&LW<br />

2 3 /4" NW&LW<br />

G256 + 0.6C, 1.0C, 1.3C, 1.5C 1,2,3 Hr.<br />

G701 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2,3 Hr.<br />

G705 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G702 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G801 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G804 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G802 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G229 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2,3 Hr.<br />

G228 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2 Hr.<br />

G243 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2 Hr.<br />

G213 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2,3 Hr.<br />

G502 + 0.6C, 1.0C, 1.3C, 1.5C<br />

G701 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2,3 Hr.<br />

G705 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G702 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G801 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G804 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G802 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G023 + 0.6C, 1.0C, 1.3C, 1.5C 2 Hr.<br />

G031 + 0.6C, 1.0C, 1.3C, 1.5C 3 Hr.<br />

G036 + 0.6C, 1.0C, 1.3C, 1.5C 3 Hr.<br />

G227 + 0.6C, 1.0C, 1.3C, 1.5C 3 Hr.<br />

G228 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2 Hr.<br />

G229 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2,3 Hr.<br />

G243 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2 Hr.<br />

G256 + 0.6C, 1.0C, 1.3C, 1.5C 1,2,3 Hr.<br />

G213 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2,3 Hr.<br />

G505 + 0.6C, 1.0C, 1.3C, 1.5C<br />

G529 + 0.6C, 1.0C, 1.3C, 1.5C 2,3 Hr.<br />

G514 + 0.6C, 1.0C, 1.3C, 1.5C 3 Hr.<br />

G523 + 0.6C, 1.0C, 1.3C, 1.5C 2 Hr.<br />

G701 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2,3 Hr.<br />

G705 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G702 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G801 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G804 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G802 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G036 + 0.6C, 1.0C, 1.3C, 1.5C 3 Hr.<br />

G033 + 0.6C, 1.0C, 1.3C, 1.5C 3 Hr.<br />

G229 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2,3 Hr.<br />

G213 + 0.6C, 1.0C, 1.3C, 1.5C 1.5,2,3 Hr.<br />

G256 + 0.6C, 1.0C, 1.3C, 1.5C 1,2,3 Hr.<br />

G529 + 0.6C, 1.0C, 1.3C, 1.5C 3 Hr.<br />

G701 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2,3 Hr.<br />

G705 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

G801 0.6C, 1.0C, 1.3C, 1.5C 1,1.5,2 Hr.<br />

NOTES:<br />

1. Concrete thickness is thickness <strong>of</strong> slab above deck, in.<br />

2. Refer to the U.L. "Fire Resistance Directory" for the necessary construction details.<br />

3. <strong>Deck</strong> finish shall be galvanized unless noted otherwise.<br />

+ Denotes deck finish is not critical when used in G0--, G2-- &G5-- Series designs. <strong>Deck</strong> finish shall be galvanized or painted.<br />