12-02.chp:Corel VENTURA - Tyco Fire Products

tyco.fire.com

12-02.chp:Corel VENTURA - Tyco Fire Products

Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500

Customer Service/Sales:

Tel: (414) 570-5000 / (800) 558-5236

Fax: (414) 570-5010 / (800) 877-1295

GEM Technical Data Book

Technical Data Book Update, December, 2002

Updating Instructions

Replace the Table of Contents dated 11-02 with the revised Table of Contents dated November, 2002.

Use the new Table of Contents as a guide when inserting the referenced new and revised technical data sheets.

REMOVE INSERT NOTES

TD106M (2-02)

TD106R (2-02)

TFP1041 (December, 2002)

TFP1061 (December, 2002)

Insert in place of the removed

sheets.

The data sheets for the DPV-1 Dry Pipe Valves have been

updated with revised trim arrangements to incorporate a

location for installing an air pressure supervisory switch. In

addition, NYC Approval for the DPV-1 Dry Pipe Valves has

been added.

TD170 (11-87)

The Primers for use with Primac Valves will only be offered as

a replacement part until further notice.

TD175 (12-89)

TD177 (12-89)

TD135 (9-86)

Manufacturing of the F460 Primac Valve has been ceased, and

orders will only be accepted for available stock. Replacement

parts will be offered until further notice.

Manufacturing of the A-4 Multimatic Valve with F461 Primac

Attachment has been ceased, and orders will only be accepted

for available stock. Replacement parts will be offered until

further notice.

The Model X03-02-000 Desiccant Dryer will continue to be

offered as a resale item.

TFP280 (11-02) TFP280 (December, 2002)

Insert in place of the removed

sheet.

TD510M (3-01)

Table B in TFP280 has been corrected with respect to

typographical errors for the 18 x 16, 18 x 18, and 20 x 16

coverage areas.

Manufacturing of the Issue D Conventional (Old Style)

Sprinklers has been ceased, and orders will only be accepted

for available stock.

TD597 (3-01)

The Central LD Large Drop Sprinkler is being offered for sale

in place of the Gem F898 Large Drop Sprinkler that is no

longer offered for sale. Manufacturing of the F898 has been

ceased, and orders will only be accepted for available stock.

The Table of Contents has been updated with reference to the

Central data sheet that can located on

www.centralsprinkler.com.


REMOVE INSERT NOTES

TD599A (2-02)

TD598M (2-02)

TFP316 (6-02)

TD598A (2-02)

TD871 (10-02)

TD1225 (4-83)

TFP312 (December, 2002)

TFP315 (December, 2002)

TFP316 (December, 2002)

TFP318 (December, 2002)

Insert in place of the removed

sheets.

The data sheets for the ESFR-25 Pendent , ESFR-17 Pendent,

ESFR-17 Upright, and ESFR-1 Pendent Sprinklers have been

revised to remove the Design Criteria sections, since this

information is now incorporated in the latest issues of NFPA 13

(2002) and FM’s Loss Prevention Data Sheet 8-9 (September,

2002). In addition, VdS Approval for the ESFR-17 and

ESFR-25 Pendent Sprinklers has been added.

Manufacturing of the Model F819 Rupture Disc Assembly has

been ceased, and orders will only be accepted for available

stock. Replacement parts will be offered until further notice.

Identification Signs will continue to be offered as a resale item.

TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446

More magazines by this user