Soil<br />

Water<br />

Plants<br />

Climate<br />

<strong>Release</strong> 3.3


About us<br />

<strong>UMS</strong>, Your partner for environmental monitoring<br />

1986 - the idea of the T5 Miniature-Tensiometer has been developed.<br />

The GSF Research Centre in Munich demanded for a small, precise and reliable<br />

Tensiometer for the controlled irrigation of experimental potted plants which<br />

partly were exposed to defined water stress.<br />

The first <strong>UMS</strong> product was born - and still is popular.<br />

Since 1991 <strong>UMS</strong> offers the complete equipment for environmental measuring<br />

systems - with <strong>UMS</strong> made sensor technique, competence and experience in<br />

planning of individual solutions and development of innovative products.<br />

About us<br />

Our team of engineers and technicians<br />

takes care of the development<br />

and production of environmental<br />

instrumentation.<br />

<strong>UMS</strong> is located in Munich, not far from<br />

leading universities and research<br />

centres in Southern Germany and<br />

Austria. With some of them, <strong>UMS</strong><br />

has not only longtime relations but<br />

close cooperations.<br />

<strong>UMS</strong> quality<br />

<strong>UMS</strong> is certified by the DIN EN<br />

ISO 9001:2000 quality standard<br />

All <strong>UMS</strong> products passed the CE<br />

conformity test procedure<br />

Monitoring systems pass a one<br />

week test run before delivery<br />

Consulting and system design<br />

It is our aim to find the right product<br />

and solution in accordance with your<br />

application - for the best possible<br />

return of time and funds.<br />

Our workshops and trainings impart<br />

knowledge on products and handling<br />

and are a platform to share ideas and<br />

experiences.<br />

Title-page: T5 miniature Tensiometer<br />

<strong>Product</strong>ion<br />

Tensiometers, pore water samplers<br />

and other products are manufactured<br />

in our own well-equipped workshop.<br />

This assures a constant quality and<br />

a certain flexibility on individual<br />

designs.<br />

<strong>UMS</strong> is member of the following<br />

committees:<br />

DBG German Soil Scientific Society<br />

ÖBG Austrian Soil Scientific Society<br />

ATV-DVWK<br />

Lysimeter Group<br />

Scientific board of the<br />

Lysimeter Group<br />

German standardization committee<br />

(DIN) NAW I 2/UA 5/AK4 for the<br />

standardization of pore water<br />

sampling and sampling methods<br />

K-net - Austrian Network of Water<br />

Competence<br />

Development and cooperations<br />

According to your requirements and<br />

intentions we design customized<br />

sensors, user interfaces and network<br />

solutions.<br />

In close cooperation with our research<br />

partners innovative components<br />

are developed and turned into new<br />

products.<br />

Service and maintenance<br />

Our technicians and engineers<br />

are available for the long-term<br />

maintenance of your systems.<br />

Our repair service will look for<br />

quickest accomplishment to keep<br />

any data loss as small as possible.<br />

Our calibration service grants many<br />

years of accurate measurements.<br />

It is our aim to support you in your tasks with best possible measurement solutions.<br />

Benefit from our engineering competence and receive complete solutions from one hand!<br />

2 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Telephone<br />

Telephone: +49-89-12 66 52-0<br />

Our office hours are Monday through<br />

Friday 8 am to 6 pm CET / CEST<br />

Fax<br />

Fax: +49-89-12 66 52-20<br />

Email<br />

Please find your contact person<br />

listed on last pages of this catalogue<br />

Distributors<br />

Please find a list of our contract<br />

distributors on the last page of this<br />

catalogue<br />

Webpage<br />

Round-the-clock information on:<br />

www.ums-muc.de<br />

Newsletter<br />

Do you wish to receive up-to-date<br />

information regularly? Our free<br />

periodically issued newsletter includes:<br />

< News at <strong>UMS</strong><br />

< Dates for workshops and tradeshows<br />

< Introduction of new products<br />

< Summaries about interesting projects<br />

and solutions<br />

If yes, please subscribe our newsletter<br />

under: www.ums-muc.de/subscribe<br />

Content<br />


Scales<br />

Scales & scientific levels for hydrologic research<br />

Soil has a key role for many<br />

environmental research studies<br />

because of its multiple functions,<br />

especially for soil water balance,<br />

water quality, food production,<br />

forestry, climate and conservation of<br />

the ecosystem.<br />

Scale 1: Soil physical laboratory<br />

scale<br />

Measuring and modelling of soil<br />

and water specific functions and<br />

characteristics with soil sample rings<br />

and miniature lysimeters.<br />

Retention curves<br />

Conductivity<br />

Sensor calibration<br />

Bio remediation<br />

Microcosm scale<br />

Soils are different, heterogeneous<br />

and highly complex. Therefore, it is<br />

a challenge to extrapolate laboratory<br />

results into the field, or punctiform<br />

results into areas, or calibrating<br />

models to expanded regions.<br />

Scale 2: Hydrologic laboratory<br />

scale<br />

Determination of hydraulic<br />

coherences with soil monoliths:<br />

Flowability<br />

Substance transport<br />

Sorption and buffer behaviour<br />

Research methodology and<br />

instrumentation needs to be aligned<br />

to the soil as well as to the objective<br />

target. <strong>UMS</strong> offers know-how,<br />

sensors and instrumentation for your<br />

research tasks.<br />

Scale 3: Lysimeter station<br />

Studies on undisturbed soil monoliths<br />

with defined surface and volume<br />

under real climatic conditions and<br />

vegetation<br />

Water balance<br />

Leachate<br />

Ground water recharge cap.<br />

Substance transport<br />

Metabolism research<br />

Cultivation methods<br />

Climatic research<br />

Energy balance<br />

Model calibration<br />

Lysimeter stations equipped by<br />

<strong>UMS</strong> are described on the following<br />

pages.<br />

<strong>UMS</strong> miniature Lysimeter<br />

GSF: soil monolith experiment<br />

GSF: Lysimeter basement<br />

Scale 4: In-the-field measuring<br />

sites<br />

Field studies to describe in situ<br />

retention curves and water fluxes or<br />

as input data for groundwater recharge<br />

models, leachate determination and<br />

soil water sampling.<br />

Scale 5: Modelling for process descriptions in catchment areas and<br />

regions<br />

Models for water and energy balance and substance transport as a tool for<br />

status description, simulations or forecasts. Useful as a decision support tool<br />

for cultivation and management of water resources. Models are calibrated with<br />

precise measurements in the laboratory or in the field.<br />

Austrian Hydrographic Service:<br />

In-the-field soil water station<br />

4 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Beside sensors and scientific instrumentation we offer complete measuring solutions -<br />

fitted to your individual tasks.<br />

Laboratory solutions<br />

This laboratory setup for soil retention<br />

curves, flux determination, pore<br />

water sampling, etc. consists of a<br />

weighable small lysimeter KL2 with<br />

which monolithic soil pillars can be<br />

excavated.<br />

A standard setup would have sensors<br />

in different soil levels, like miniature<br />

Tensiometers T5 for matrix potential<br />

and FD-probes for volumetric<br />

water content measurements,<br />

temperature probes, miniature pore<br />

water samplers, a high-resolution<br />

scale and a ceramic bottom plate for<br />

leachate sampling or for generating a<br />

simulated tension.<br />

Customized solutions<br />

In 1988 <strong>UMS</strong> installed a tension<br />

controlled scientific irrigation<br />

system for plant specific soil water<br />

conditioning. Date, time, duration of<br />

irrigation and the matrix potential are<br />

monitored on 64 channels.<br />

This customized solution is operating<br />

now for 18 years!<br />

Extreme cases<br />

In the field or in situ measuring sites<br />

normally need individual design in<br />

accordance to site and soil specific<br />

situation and scientific tasks.<br />

This system in Northern France<br />

for example measures volumetric<br />

water content, water tension and<br />

temperature in a chalk soil down to<br />

a depth of 10 meters. But the record<br />

is still held by 20 meter Tensiometers<br />

installed in the Oman desert.<br />

Systems & Solutions<br />

Field monitoring stations<br />

Most of all outdoor stations need to<br />

be resistant against environmental<br />

influences, including lightning or<br />

nibbling rodents. Yet, they should<br />

still be user-friendly regarding the<br />

installation as well as servicing, power<br />

supply and data read-out.<br />

To ensure this, <strong>UMS</strong> stations are well<br />

designed, pre-assembled and pass a<br />

one week test run before delivery.<br />

GSM communication<br />

A solar powered station with GSM<br />

data transmission is the optimum in<br />

service friendliness. At this station<br />

located at the Zurich lake the status<br />

is checked, data is downloaded<br />

and configurations are changed<br />

conveniently from the operator’s<br />

office. But please consider a proper<br />

anti-theft and vandalism protection.<br />

Service friendly solutions<br />

This combined soil and weather<br />

monitoring station is equipped with<br />

about 50 different sensors on a 10<br />

meter mast. You think you need a<br />

climber to service the sensors?<br />

This <strong>UMS</strong> designed mast can simply<br />

be tilted by removing a single bolt<br />

for easy servicing and calibration<br />

routines.<br />

Let us know your requirements and ask for a quotation for a complete solution<br />

All systems pass a test run and are pre-assembled as far as wished<br />

Stations are supplied with handbook and documentation in English language<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

5


Tensiometer<br />

Tensiometers for direct measurement of the soil water tension<br />

All water movements in soils are<br />

directly depending on the soil water<br />

tension, as water - in soils as well as<br />

on surface - will always move from<br />

areas of higher potential to areas of<br />

lower potential.<br />

Main water movements occur at low<br />

tensions which only Tensiometers<br />

measure directly and precisely.<br />

Naturally embedded soils are<br />

heterogeneous. Thus, soil water<br />

processes are not only affected by<br />

precipitation and evapotranspiration,<br />

but also by texture, grain size, cracks,<br />

compactness, aggregation, roots and<br />

cavities. Tensiometer measurements<br />

are not directly influenced by the soil<br />

heterogeneity.<br />

T1 T3 T4 T5 T8 TS1<br />

Shaft Sensor<br />

How does it work?<br />

Soil water and Tensiometer water<br />

have contact through the porous<br />

ceramic as a wetted porous ceramic<br />

creates an ideal pore/water interface.<br />

The soil water tension is directly<br />

conducted to the pressure transducer<br />

which offers a continuous signal. The<br />

atmospheric reference pressure is<br />

provided through a membrane on the<br />

cable, a distinctive patented method.<br />

pF / wc - relation curve<br />

Benefits<br />

Tensiometers are functional up to<br />

85 kPa, correspondingly pF 2.9<br />

The unique T5x can reach 200 kPa<br />

Tensiometers T1, T3, T4 and T5<br />

have a common calibration:<br />

0 kPa = 0 mV to -85 kPa= -85 mV<br />

Tensiometers T8 and TS1 have an<br />

amplified linear signal output<br />

Virtually unbreakable homogenous<br />

sinter ceramic cup on T4, T8<br />

Contact Tensiometers<br />

Spot readings with the INFIELD7b<br />

handheld<br />

Applications<br />

Spot readings:<br />

T1 or T3<br />

Low-cost-applications:<br />

T1 or T3<br />

Irrigation control:<br />

T3<br />

Environmental monitoring:<br />

T4, T8 or TS1<br />

Lysimeter sites:<br />

T4, T8 or TS1<br />

Punctiform, pot or laboratory<br />

measurements: T5<br />

Limits<br />

T1, T3 and T5 must be protected<br />

from frost<br />

Dry soil draws off the water<br />

Measuring site at the Zurich airport<br />

Georg von Unold<br />

Tel.: +49 (0) 89 / 12 66 52 - 15<br />

eMail: gvu@ums-muc.de More than 10 000 Tensiometers sold worldwide -<br />

a sign of confidence for <strong>UMS</strong> quality and tensiometry know-how<br />

6 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


T5<br />

129<br />

Active<br />

Time<br />

HYST: 5hPa<br />

With the new modular bus concept<br />

tensioLINK it is possible to establish a<br />

flexible and effective measuring site.<br />

The modular concept allows an easy<br />

extension or optimal adaption of the<br />

system to many measuring tasks.<br />

Benefits<br />

Easy installation by networking<br />

Digital data transfer over large<br />

distances<br />

New sensor functions e.g.<br />

integrated data logger<br />

Simple transmission protocol<br />

allows integration of non-system<br />

data acquisition devices<br />

Supported devices<br />

Infield7b<br />

TS1<br />

new T8 (Version 2005)<br />

SIS (8-pin cable version)<br />

VS-twin/-single and VS-pro<br />

... more to come<br />

Interference safe transmission<br />

The newest generation of products<br />

from <strong>UMS</strong> are fitted to the serial<br />

measuring bus tensioLINK.<br />

tensioLINK is based on the RS485<br />

standard. It is a 2-wire bus for data<br />

transmission over several joints<br />

over large distances. The differential<br />

transmission eliminates interferences<br />

to assure safe communication over<br />

large distances.<br />

Modular concept for easy handling and flexible extensibility<br />

Easy data download also with nonsystem<br />

data acquisition devices<br />

To make sensors compatible to nonsystem<br />

data acquisition devices<br />

the tensioLINK protocol can be<br />

programmed with simple ASCII<br />

instructions. Thus, e. g. data loggers<br />

with a RS485 sensor interface can<br />

connect to and read out numerous<br />

sensors without the need of<br />

expensive analogue inputs.<br />

Flexibility by networking<br />

To implement new functions into<br />

sensors or devices and still be<br />

flexible in cabling an analogue cable<br />

transmission is not sufficient any<br />

more. A serial interface is required for<br />

digital communication with sensors.<br />

+538hPa<br />

Soll: 540hPa<br />

tensioLINK<br />

Maximum compatibility<br />

To guarantee the maximum<br />

compatibility of our products all<br />

tensioLINK sensors and instruments<br />

still have analogue outputs in addition.<br />

Thus, they can be connected to any<br />

standard measuring system which<br />

requires analogue inputs.<br />

New sensor functions<br />

The serial interface offers new<br />

possibilities like storage of readings<br />

in the sensor itself (data logger),<br />

calibration, configuration of controlling<br />

functions etc. And of course the<br />

accurate error free transfer of readings<br />

without analogue cabling.<br />

Tensiometer<br />

The newest generation of <strong>UMS</strong><br />

sensors and instruments are fitted<br />

with the tensioLINK bus (see above).<br />

To connect them to a PC or Laptop a<br />

USB adapter cable and the Windows<br />

software tensioVIEW is available. The<br />

software recognizes all instruments<br />

connected to the bus.<br />

tensioVIEW is used for sensor<br />

configuration and data read-out. Edit<br />

for example the set value and current<br />

value of a VS vacuum station, further<br />

parameters and the stored readings<br />

of the connected Tensiometer.<br />

For laboratory applications no<br />

additional tools are required beside<br />

tensioLINK and tensioVIEW:<br />

the sensor readings are directly<br />

downloaded to the computer.<br />

tensioVIEW<br />

The tensioLINK USB converter is<br />

used for direct connection of sensors<br />

and devices with serial tensioLINK<br />

interface to a PC.<br />

Benefits<br />

Cost-effective laboratory application<br />

with a PC used as a logger<br />

Direct connection of tensioLINK<br />

instruments like TS1, T8-2005, SIS,<br />

Infield7, VS<br />

Easy sensor configuration and data<br />

read-out with the free tensioVIEW<br />

software<br />

USB PC adapter<br />

Item<br />

Art.no.<br />

USB adapter tL-USB<br />

USB adapter mini* tL-USB-mini<br />

* Only for Infield7 and VS<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

7


Tensiometer<br />

T1<br />

Sensor head T1K<br />

Measuring range: +10 kPa ... -70 kPa<br />

Output signal: +10 mV ... -70 mV<br />

Accuracy: ±0.5 kPa<br />

Supply: typ. 10.6 VDC / 1.3 mA<br />

Cable:<br />

1.5 m; 4-pin plug M12<br />

Shaft T1S<br />

Shaft:<br />

Ø 20 mm; acrylic<br />

Shaft lengths: 10 ... 200 cm<br />

Porous ceramic: Ø 20 mm; length 60 mm<br />

Bubble point: 1 bar<br />

Septum: Silicone<br />

For spot readings of the water<br />

tension: Any number of Tensiometer<br />

shafts T1S are installed in the ground,<br />

filled with water and plugged with the<br />

septum. With only one sensor head<br />

T1K and one INFIELD7b handheld unit<br />

all shafts can be read out one by one.<br />

The INFIELD compensates the vertical<br />

water column and displays and stores<br />

the readings in kPa.<br />

Applications<br />

Spot readings of soil water<br />

tension<br />

Benefits<br />

Low-cost solution for numerous<br />

measuring points<br />

Easy handling, filling status obvious<br />

by transparent shaft<br />

Limits<br />

Not for horizontal installation<br />

Frost free usage only<br />

Not for dry soils<br />

Accuracy not as good as T3<br />

Water column in shaft reduces the<br />

measuring range: 10 cm = -1 kPa<br />

Item<br />

T1 sensor head<br />

T1 shaft<br />

Art.no.<br />

T1K-20<br />

T1S-...<br />

Indicate required shaft lengths on an<br />

order, e. g.40 cm = T1S-40<br />

T3<br />

The T3 is of great advantage especially<br />

for rough field conditions and when<br />

easy handling is preferred.<br />

For example as a control sensor<br />

for irrigation systems. The fill level<br />

can easily be checked through the<br />

transparent shaft.<br />

Applications<br />

In-the-field or in greenhouses<br />

Water balance studies<br />

Control sensor for irrigation<br />

Monitoring studies with data<br />

logger, e. g. the DL6-te<br />

Spot readings in combination with<br />

the INFIELD7b<br />

Benefits<br />

Easy handling<br />

Solid construction<br />

Balanced signals<br />

Measuring range: +10 kPa ... -70 kPa<br />

Output signal: +10 mV ... -70 mV<br />

Accuracy: ±0.5 kPa<br />

Supply:<br />

typ. 10.6 VDC / 1.3 mA<br />

Shaft:<br />

Ø 20 mm; acrylic<br />

Shaft lengths: 10 ... 200 cm<br />

Porous ceramic: Ø 20 mm; length 60 mm<br />

Bubble point: 1 bar<br />

Cable:<br />

1.5 m; 4-pin plug M12<br />

Limits<br />

Not for horizontal installation<br />

Frost free usage only<br />

Not for dry soils<br />

Water column in shaft reduces the<br />

measuring range: 10 cm = -1 kPa<br />

Connecting cables CC-4 on page 17<br />

Item<br />

T3<br />

Art.no.<br />

T3-...<br />

Indicate required shaft length on an<br />

order, e. g. 40 cm = T3-40<br />

8 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


The T4 precision Tensiometer -<br />

developed for outdoor monitoring<br />

projects. Only the ceramic cup is<br />

filled with water for highest accuracy<br />

and year-round operation.<br />

Optionally with external refilling<br />

The model T4e with external refilling<br />

can be refilled or emptied without<br />

removing it from the soil.<br />

Applications<br />

Field measurements<br />

Water balance, leaching, transport<br />

studies, model calibration<br />

Ecological impact studies<br />

Agricultural or forestal studies<br />

In-situ retention curves<br />

Data logger applications<br />

Spot readings with the INFIELD7b<br />

T4<br />

Tensiometer<br />

Item<br />

T4<br />

T4 with external<br />

refilling<br />

Art.no.<br />

T4-...<br />

T4e-...<br />

Indicate required shaft length on an<br />

order, e. g. 40 cm = T4-40<br />

Benefits<br />

Reliable outdoor tensiometer<br />

Solid construction<br />

Horizontal or vertical installation in<br />

any orientation<br />

Year-round operation when<br />

installed deeper than 30 cm<br />

Limits<br />

Not for dry soils<br />

Connecting cables CC-4 on page 17.<br />

Measuring range: +100 kPa ... -85 kPa<br />

Output signal: +100 mV ... -85 mV<br />

Accuracy: ±0.5 kPa<br />

Supply: typ. 10.6 VDC / 1.3 mA<br />

Shaft:<br />

Ø 25 mm; acrylic<br />

Shaft lengths: 10 ... 200 cm<br />

Shaft extensions: Possible on request<br />

Porous ceramic: Ø 24 mm; length 60 mm<br />

Bubble point: 15 bar<br />

Cable ex corpus: 1,5 m; 4-pin plug M12<br />

The T8 is characterised by maximum<br />

user comfort and was developed for<br />

long term monitoring projects.<br />

Applications<br />

Field measurements<br />

Water balance, leaching, transport<br />

studies, model calibration<br />

Ecological impact studies<br />

Agricultural or forestal studies<br />

In-situ retention curves<br />

Data logger applications<br />

Spot readings with the INFIELD7b<br />

T8<br />

Item<br />

T8<br />

Art.no.<br />

T8-...<br />

Indicate required shaft length on an<br />

order, e. g. 40 cm = T8-40<br />

Benefits<br />

Integrated amplifier<br />

Integrated soil temperature sensor<br />

Integrated fill level indicator<br />

Integrated external refilling: refill or<br />

empty the cup through capillary<br />

tubes without removing the T8<br />

from the soil<br />

Solid construction<br />

Limits<br />

Not for dry soils<br />

Connecting cables CC-8 on page 17<br />

Measuring range: +100 kPa ... -85 kPa<br />

Output signal: 0 mV ... +2000 mV<br />

Accuracy: ±0.5 kPa<br />

Supply:<br />

6 ... 20 VDC / 7 mA<br />

Shaft:<br />

Ø 25 mm; acrylic<br />

Shaft length: 10 ... 200 cm<br />

Shaft extensions: Possible on request<br />

Porous ceramic: Ø 24 mm; length 60 mm<br />

Bubble point: 15 bar<br />

Cable ex corpus: 1.5 m; 8-pin plug M12<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

9


Tensiometer<br />

T5<br />

Corpus<br />

Shaft<br />

The T5 Tensiometer is specially<br />

made for punctual measurements,<br />

for example in soil columns, small<br />

lysimeters or pots.<br />

With an active surface of only 0,5 cm 2<br />

and a diameter of 5 mm the ceramic<br />

tip has all advantages of small<br />

dimensions: little soil disturbance,<br />

punctual pick-up and fast response.<br />

The special version T5x can achieve a<br />

measuring range of 200 kPa.<br />

The T5 can be installed in any position<br />

and orientation. Bubbles are easily<br />

detectable through the transparent<br />

shaft. Output signals are balanced.<br />

New Auger Kit for T5 ...<br />

... for a perfect fit in the soil and<br />

minimised soil compression.<br />

Measuring range: +100 kPa ... -85 kPa<br />

Output signal: +100 mV ... -85 mV<br />

Accuracy: ±0.5 kPa<br />

Supply:<br />

typ. 10.6 VDC / 1.3 mA<br />

Shaft:<br />

Ø 5 mm<br />

Shaft length: 2 ... 20 cm<br />

Corpus: Ø 20 mm, length 3.5 cm<br />

Cable:<br />

1,5 m; 4-pin plug M12<br />

Delivery incl. T5 in carrying case,<br />

refill tools, manual.<br />

Please order connecting cables separately<br />

Benefits<br />

Accurate zero-tension reading<br />

Fast response: With sufficient filling<br />

the T5 responds within 5 seconds<br />

to an applied air pressure change<br />

of 0 to 85 kPa<br />

Most standard T5 reach a range of<br />

at least 150 kPa when delivered.<br />

Limits<br />

Not for dry soils<br />

Not frost resistant<br />

In the field applications require<br />

impact protection<br />

Item<br />

Art.no.<br />

T5<br />

T5-...<br />

T5x expanded range T5x-...<br />

Auger Kit<br />

TBT5<br />

Indicate required shaft length on an<br />

order, e. g. 7 cm = T5-7<br />

Applications<br />

Punctual measurement of water<br />

potential<br />

Miniature lysimeter studies,<br />

together with micro samplers and<br />

soil temperature probes<br />

Determination of pF/wc and<br />

K/Psi in soil columns, soil cores or<br />

soil sampling rings<br />

Determination of leachate and<br />

capillary water movements<br />

Controlling irrigation<br />

Pot experiments<br />

Measurements in the upper soil<br />

horizons in the field<br />

Monitoring with data loggers<br />

Spot readings with the INFIELD7b<br />

Special T5x with expanded range<br />

The T5x is the first pressure transducer<br />

Tensiometer that can reach an<br />

expanded measuring range of up to<br />

200 kPa when it is specially filled (see<br />

fig. and ordering information).<br />

Response and filling though are<br />

reduced compared to a standard T5.<br />

10 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


If your task is soil water monitoring<br />

you know the problem: water<br />

vaporizes and is lost. If soil gets dryer<br />

than about 85 kPa, no tensiometer is<br />

able to take measurements. Still, as<br />

only little water movements occur in<br />

extreme dry soil, losing readings is<br />

tolerable. Then, when the soil gets<br />

wet again, the Tensiometer could<br />

actually restart measurements - but<br />

first it needs to be refilled again.<br />

Now, the TS1 solves this problem:<br />

In case the cup needs to be refilled<br />

and soil water is available the internal<br />

pump will draw up water out of the<br />

soil, refill the cup and remove all<br />

air through an exhaust outlet - fully<br />

automatically.<br />

Even if only a bubble is detected the<br />

cup is deaerated automatically.<br />

Contrariwise, if the temperature probe<br />

indicates emerging frost, the TS1<br />

empties itself to prevent damages<br />

caused by freezing.<br />

Applications<br />

Field measurements of pF/wc<br />

Ecological impact studies<br />

Agricultural studies<br />

Model calibration<br />

Long time monitoring studies<br />

Water balance and transport<br />

studies<br />

Benefits<br />

Automatic self-refilling and<br />

deaerating<br />

Continuous fill level controlling<br />

Optional pore water sampling<br />

Automatic emptying before frost<br />

Integrated soil temperature probe<br />

Auto logging function<br />

tensioLINK and RS485 interface<br />

Low maintenance<br />

Limits<br />

Not for permanent dry soils<br />

Processor<br />

As standard two analogue outputs<br />

for pressure and temperature are<br />

available. For extended<br />

measuring tasks like large number<br />

of Tensiometers the TS1 can be bus<br />

linked.<br />

The configuration of pumping<br />

intervals, pumping volume,<br />

installation angle etc. is done by PC<br />

connection or with an INFIELD7b.<br />

If no correct readings are available<br />

an error message is registered. This<br />

ensures the data integrity.<br />

Pore water sampler<br />

When used as an intelligent pore<br />

water sampler the water drawn up<br />

from the soil is not removed through<br />

the exhaust but stored inside the<br />

shaft. Regulated by the controller,<br />

the water is extracted with a<br />

pressure that is slightly higher than the<br />

current soil water tension measured<br />

by the TS1. Thus, soil disturbance, filtration<br />

effects, lime accumulation or<br />

pH-value shifts are prevented.<br />

The intervals for automatic sampling<br />

as well as the sample amount can be<br />

set in the controller.<br />

Current consumption for<br />

measurements is less than 1 mA, for<br />

pump operation less than 10 mA.<br />

TS1<br />

Tensiometer<br />

Measuring range: +100 kPa ... -100 kPa<br />

Accuracy: ±0.5 kPa<br />

Temperature<br />

Measuring range: -30 °C ... +70 °C<br />

Accuracy: ±0.1 K<br />

Output signal<br />

Analog:<br />

selectable ranges:<br />

2 x 0 ... 1 V / 2 V / 5 V<br />

Digital:<br />

RS 485, tensioLINK<br />

Supply:<br />

6 ... 20 VDC / typ. 1 mA<br />

Housing:<br />

Ø 40 mm, GFK/PMMA<br />

Cable:<br />

1.5 m; 8-pin plug M12<br />

Tensiometer<br />

Item<br />

TS1<br />

TS1 with pore water<br />

sampling<br />

Art.no.<br />

TS1-...<br />

TS1s-...<br />

Indicate required shaft length on an<br />

order, e. g. 30 cm = TS1-30<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

11


Tensiometer<br />

INFIELD7<br />

The INFIELD7 is a multi-functional<br />

handheld read-out unit for Tensiometers<br />

and other soil probes.<br />

The following probe types can be<br />

connected:<br />

<strong>UMS</strong> Tensiometers T1, T3, T4,<br />

T5, T8 and TS1<br />

SIS smart gypsum block<br />

Watermark and Soilmoisture<br />

gypsum block<br />

FD Thetaprobe ML2x*<br />

FD Echoprobe<br />

(EC-5*,EC-10*,EC-20*)<br />

NEW! 5TE*, EC-TM* and 10HS*<br />

Temperature probes (<strong>UMS</strong> TH2,<br />

certain Thermistors, PT1000)<br />

All sensors with tensioLINKinterface<br />

like TS1, SIS<br />

*Need <strong>UMS</strong> 4-pin plug or adapter<br />

cable<br />

Benefits<br />

Memory for 250 readings<br />

Vertical water column<br />

compensation for Tensiometers<br />

Download readings to PC with<br />

accessory USB adapter<br />

Firmware upgradeable with<br />

tensioLink software<br />

Water tension: -100 kPa... +100 kPa<br />

New! Powered with<br />

Accuracy: 0.01 kPa<br />

easy to replace 4 x AA Temperature: -30°C... +70 °C<br />

standard batteries<br />

Accuracy: 0.1 K<br />

Memory: 250 readings<br />

Housing: IP65<br />

Size:<br />

17 x 9 x 3 cm<br />

Connectors: 4- and 8-pin plug M12<br />

Batteries: 4 x AA 1,5V<br />

Item<br />

Infield 7<br />

USB PC adapter<br />

Art.no.<br />

INFIELD7<br />

tLINK-USB<br />

Auger<br />

<strong>UMS</strong> special auger for Tensiometers and pore water samplers<br />

The cutting edge of the auger has a<br />

tapered tip similar to the shape of a<br />

Tensiometer or soil water sampler.<br />

Thus, the bore hole is large enough to<br />

insert the shaft, but the cup will have<br />

a tight and perfect fit to the soil.<br />

The not recommendable slurrying<br />

of the cup with quartz clay can be<br />

avoided.<br />

A divisible auger set includes:<br />

Cutting edge with tapered tip<br />

Handle with hammering head<br />

Parts have threaded connection and<br />

can be extended with one or more<br />

100 cm extension rods.<br />

Extension rod Art.no.: b.TBE-100<br />

Benefits<br />

Simplifies installation of shafts<br />

Avoids slurrying<br />

Multipart - divisible - extendable<br />

Cutting edge part<br />

Extension rod<br />

Tapered tip<br />

Handle<br />

TB-20<br />

TB-25<br />

Dimensions<br />

Cutting edge Ø 22 mm x 50 cm Ø 26 mm x 50 cm<br />

Tip Ø 20 mm x 5.6 cm Ø 24 mm x 5.6 cm<br />

Total length 1.25 m 1.5 m<br />

for shafts with Ø 20 mm Ø 24 mm<br />

Art.no. b.TB-20/125 b.TB-25/150<br />

12 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


BKT468<br />

Refill kit for T4, T6 and T8<br />

Tensiometers, including base stand<br />

with clamps, adapter that fits to T4,<br />

T6 and T8 sensor bodies, 500 ml<br />

bottle, vacuum gauge, tubes, beaker,<br />

refilling syringe, pliers.<br />

BKT5<br />

Refill kit for T5 Tensiometers,<br />

including base stand with clamps,<br />

adapter that fits to T5 sensor bodies,<br />

500 ml bottle, vacuum gauge, tubes,<br />

beaker, refilling syringe.<br />

Kits require additional vacuum pump.<br />

With the laboratory refill kits<br />

and adapters large quantities of<br />

Tensiometers can be deaerated and<br />

refilled at the same time. They are<br />

useful, but not essential.<br />

Note: T4e and T8 are supplied with an<br />

external refilling tool.<br />

Item<br />

Art.no.<br />

for T4, T6, T8 BKT468<br />

for T5<br />

BKT5<br />

8 mbar vacuum pump N-8<br />

Additional adapter piece<br />

for T4, T6, T8 BA-T468<br />

Additional adapter piece<br />

for T5<br />

BA-T5<br />

More accessories on request<br />

BKT<br />

Tensiometer<br />

<strong>UMS</strong> type connecting or extension<br />

cables for data logger applications<br />

etc.<br />

Connecting cables are fitted with<br />

a female plug and 12 cm wire end<br />

sleeves.<br />

Extension cables have one each male<br />

and female plug.<br />

Plugs are supplied with protective<br />

cap.<br />

Item<br />

Art.no.<br />

4-pin connecting cable for T3, T4, T5<br />

Length 5 m CC-4/5<br />

Length 10 m CC-4/10<br />

Length 20 m CC-4/20<br />

4-pin extension cable<br />

Length 5 m EC-4/5<br />

Length 10 m EC-4/10<br />

Length 20 m EC-4/20<br />

Cable<br />

Item<br />

Art.no.<br />

8-pin connecting cable for T8, TS1<br />

Length 5 m CC-8/5<br />

Length 10 m CC-8/10<br />

Length 20 m CC-8/20<br />

8-pin extension cable<br />

Length 5 m EC-8/5<br />

Length 10 m EC-8/10<br />

Length 20 m EC-8/20<br />

TV-Batt<br />

TV-Batt module<br />

TV-Batt DL2e<br />

Sensors with non-amplified bridge circuits<br />

like the Tensiometers T3, T4 and<br />

T5 require a stabilised power supply.<br />

For connecting them to Data loggers,<br />

their output signal should also have a<br />

logger specific signal level. The TVbatt<br />

power supply offers both requirements.<br />

The Tensiometer signals then<br />

are in a range of


Tensiometer<br />

SIS<br />

Soil water tension<br />

Measuring range: -20 kPa ... -200 kPa<br />

Updating: every 5 minutes<br />

Temperature<br />

Measuring range: -10°C ... +60°C<br />

Accuracy: ±1.5 K<br />

Impedance: 10 kOhm<br />

Supply: 6 ... 20 VDC, typ. 2,5 mA<br />

Matrix Sensor: Watermark 200SS<br />

Size:<br />

Ø 25 mm x 116 mm<br />

Extended version only<br />

Alarm signal: 0 V; +5 V, 2 thresholds<br />

with hysteresis<br />

Interface: RS 485, tensioLINK<br />

Item<br />

Art.no.<br />

Smart Irrigation Sensor SIS-W-...<br />

Standard version<br />

- 4-pin cable -L4<br />

- 4-pin plug M12 -C4<br />

Extended version<br />

- 8-pin cable -L8<br />

- 8-pin plug M12 -C<br />

Smart Irrigation Sensor<br />

Granular matrix sensor with linear<br />

output signal.<br />

The SIS is a combination of the wellknown<br />

Watermark(R) granular matrix<br />

soil moisture sensor type 200SS<br />

and a special amplifier which offers<br />

a fully linearised and temperature<br />

compensated DC-voltage output<br />

signal.<br />

The amplifier uses a new, patent<br />

pending technique for the extremely<br />

accurate measurement of the sensor<br />

element.<br />

The linear voltage signal reduces the<br />

efforts for the electronic measuring<br />

equipment and cable connections.<br />

The temperature compensation<br />

directly picks up the soil temperature.<br />

Thus, the otherwise problematic<br />

temperature difference between<br />

logger and sensor is avoided.<br />

An extended version features a<br />

programmable digital alarm signal<br />

for irrigation issues and a serial<br />

interface for bus linking and<br />

temperature read-out.<br />

DL6-te<br />

Benefits<br />

Stand-alone: no external battery or<br />

outdoor protection required<br />

Battery capacity approx. 1 year<br />

M12 connector plugs for <strong>UMS</strong><br />

sensor cables or extension cables<br />

EC-4/...<br />

RS232-interface plug<br />

Channel 1 ... 6: Tensiometers<br />

Measuring range: +1.5 kPa... -110 kPa<br />

Accuracy: ±0.05 kPa<br />

Channel 7: Temperature -20 ... +60°C<br />

Channel 8: Counter, max. 5 / s<br />

Channel 9: Relay switch (alarm)<br />

Memory: 16 000 readings<br />

Logg intervals: 1 s ... 24 h<br />

Working temp.: -20 ... +60°C<br />

Batteries: 6 x AA (Mignon-Alkaline)<br />

Enclosure: IP68 (Plugs IP67),<br />

15x18x7 cm; < 1 kg<br />

Tensiometer data logger<br />

Stand-alone 6-channel logger for<br />

<strong>UMS</strong> Tensiometers T3, T4 and<br />

T5 with internal sensor supply in<br />

weatherproof enclosure. Additional<br />

channel for one counter (rain gauge)<br />

and one temperature sensor (2k<br />

Thermistor) plus one alarm output.<br />

The model DL6-te is a modification<br />

of the Delta-T logger DL6, specially<br />

adapted for taking measurements<br />

with the <strong>UMS</strong> standard Tensiometers<br />

T3, T4 and T5.<br />

The internal batteries will supply<br />

sensors for up to one year (with<br />

normal intervals).<br />

Accelerated recording<br />

With this optional setting the<br />

recording rate is doubled when the<br />

connected rain gauge indicates<br />

rainfall - the penetration into the soil<br />

of a wetting front is recorded.<br />

Versions<br />

DL6-t8 logger for up to six T8<br />

Tensiometers without reading the T8-<br />

temperature output, or three T8 with<br />

both tension and temperature.<br />

Standard DL6 for Theta- or profile<br />

probes or sensors 0 ... 1 V.<br />

Item<br />

Art.no.<br />

DL6-te for T3, T4, T5 DL6-te<br />

DL6-t8 for T8 DL6-t8<br />

Please order separately:<br />

Extension cables EC-4 or EC-8<br />

14 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Low cost solution<br />

With the 6-channel data logger<br />

DL6 or the modified Tensiometer<br />

logger DL6-te a basic but functional<br />

system for monitoring tasks can be<br />

established.<br />

To the DL6 respectively DL6-te<br />

connect:<br />

1 to 6 Tensiometers<br />

or 1 to 6 Smart gypsum blocks<br />

or 1 to 6 Thetaprobes<br />

plus<br />

1 rain gauge<br />

1 temperature probe<br />

1 alarm output<br />

Low cost solution<br />

Rain gauge<br />

DL6-te<br />

Tensiometers<br />

Tensiometer<br />

Field monitoring station<br />

In <strong>UMS</strong> field monitoring stations<br />

different soil and climatic sensors are<br />

combined to a particularly cutomized<br />

monitoring station.<br />

Choose between portable or fixed<br />

masts, different enclosures and<br />

power supply options. All parts have<br />

proven long-time reliability under<br />

environmental conditions: watertight<br />

plug connectors, UV-resistant cable<br />

sheaths, etc.<br />

Field monitoring<br />

Standard long term monitoring<br />

station<br />

In the custom-made <strong>UMS</strong> monitoring<br />

stations multiple soil monitoring<br />

sensors as well as climatic sensors<br />

are combined to a system that will<br />

exactly meet the users demands.<br />

We supply surface stations or<br />

installations from wells or ditches,<br />

including sensors, data acquisition<br />

system, enclosure, well construction,<br />

power supply etc.<br />

Long term monitoring<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

15


Soil water sampling<br />

Soil water sampling<br />

<strong>UMS</strong> offers a wide range of pore<br />

water samplers, leachate samplers<br />

and vacuum devices. For straight<br />

results it is decisive to select the<br />

suitable material, the correct type<br />

of sampler and the proper vacuum<br />

method.<br />

Should I use suction cups or suction<br />

plates?<br />

For extracting soil water for chemical<br />

analysis pore water samplers with<br />

cup are used (qualitative analysis).<br />

Cups are easier to install than plates.<br />

For determination of hydrologic<br />

loading of water and substances<br />

porous plates are suitable. Plates<br />

are enclosed by a cylinder to prevent<br />

that water will run around the plate<br />

(vacuum too low) or that water from a<br />

too large catchment span is extracted<br />

(vacuum too large). On lysimeter<br />

sites the cylinder reaches as far up as<br />

the soil surface. In contrary, leachate<br />

samplers are installed below the soil<br />

water shed.<br />

Leachate monitoring IRGO-Slovenia<br />

For pore water samplers a bubble<br />

point of 100 kPa (= 1000 hPa) is<br />

standard. For leachate samplers a<br />

bubble point of 10 kPa (= 100 hPa) is<br />

sufficient.<br />

Evacuation of sampling bottles with a portable vacuum pump<br />

How many samplers in a system?<br />

The number of suction cups connected<br />

to one vacuum source is theoretically<br />

not limited, as the vacuum once<br />

applied will stay and only the volume<br />

of water must compensated by<br />

the volume of air from the vacuum<br />

pump.<br />

In practise, we recommend to connect<br />

not more than about ten samplers to<br />

one vacuum unit for two reasons:<br />

1, If only one leak occurs (broken cup<br />

or faulty connection) the complete<br />

vacuum system stops working.<br />

2, If at one point the soil is drier than<br />

the cup‘s bubble point, the complete<br />

system stops working.<br />

3, It is much easier to handle small<br />

systems.<br />

Which porous material should be<br />

used for which substances?<br />

In the description of each sampler<br />

on the following pages you will find<br />

recommendations for the suitability.<br />

Still, the chemical interactions of<br />

soil water with the porous material,<br />

the vacuum level and the method<br />

of storage are complex. Therefore,<br />

please contact us in case of doubt.<br />

<strong>UMS</strong> developed a standard test<br />

procedure in co-operation with<br />

the Technical University Munich-<br />

Weihenstephan.<br />

A data base for suitability of several<br />

samplers is available now!<br />

Answers to FAQs<br />

Installation of cups, tubes and<br />

bottles in frost free depths only!<br />

Bottles and cups should be installed<br />

at the same level to prevent varying<br />

hydrostatic potentials.<br />

Water samples should be stored<br />

dark and at soil temperature, e. g.<br />

with the <strong>UMS</strong> sampling bottle box.<br />

Carefully remove the organic layer<br />

before augering in the mineral soil<br />

layer.<br />

Conditioning<br />

We advise not to flush the ceramics<br />

with any acid solution, as this can<br />

destroy ceramics or change their<br />

chemical behaviour. Discard the first<br />

samples after installation.<br />

Suction tubes should be as short as<br />

possible.<br />

Many air bubbles within the system<br />

reduce the vacuum.<br />

Shafts are marked so they can be<br />

installed in the optimal orientation.<br />

Sampling bottle box with sampling bottles<br />

Contact soil water<br />

Georg von Unold<br />

Tel.: +49 (0) 89 / 12 66 52 - 15<br />

eMail: gvu@ums-muc.de<br />

Find a regularly updated list for the<br />

suitability of sampler materials for<br />

different substances and matters<br />

on: www.ums-muc.de\SuctionCups<br />

16 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Which vacuum should be applied?<br />

To extract soil water in the unsaturated<br />

zone the soil water tension (retention<br />

force) has to be surpassed by the<br />

sampler‘s potential - a vacuum needs<br />

to be applied.<br />

The vacuum should be as close as<br />

possible to the in-situ soil water<br />

tension, as i.e. carbon will fall out in<br />

high vacuum.<br />

Variations of the pressure difference<br />

between the sampler’s inside and<br />

outside will lead to different filtration<br />

results - thus, memory effects<br />

occur. This is prevented by a tension<br />

controlled vacuum unit.<br />

Please note that water can only be<br />

extracted if water is available. The<br />

Example for a tension controlled vacuum<br />

<strong>UMS</strong> offers three different vacuum methods - the most suitable will depend on your task.<br />

1. The simple method<br />

Evacuate your sampling bottle down<br />

to approx. 50 kPa. If the soil water<br />

tension is lower than 50 kPa, soil<br />

water solution will be extracted until<br />

vacuum and soil water tension are<br />

equalized. When the samples are<br />

collected, the bottle is evacuated<br />

again.<br />

bigger the soil pores are, the less<br />

water is available at rising tensions!<br />

Sampling is possible in stony soils up<br />

to pF 1, in sandy soils up to pF 2, and<br />

in clay soils up to pF 2.7.<br />

Suction cups always act as chemical<br />

and physical filter. High vacuum<br />

applied at soils close to saturation<br />

cause transport of small particles into<br />

the sampler‘s pores. There is nearly<br />

no chance to reverse this process<br />

even by applying pressure, as around<br />

the cup an area of small particles will<br />

get accumulated.<br />

The effective active suction force is<br />

the difference of soil water tension<br />

and applied vacuum.<br />

2. The constant vacuum method<br />

A constant vacuum is continuously<br />

maintained by a regulated vacuum<br />

pump The vacuum can be set<br />

between atmospheric pressure and<br />

85 kPa.<br />

Rain<br />

event<br />

3. Tension controlled extraction<br />

A Tensiometer measures the soil<br />

water tension. The programmable<br />

vacuum station VS automatically<br />

supplies a vacuum in correspondence<br />

to the measured tension. Due to the<br />

numerous functions of the unit an<br />

optimal adaptation to the sampling<br />

task is possible.<br />

Soil water sampling<br />

Leachate samplers for example are<br />

supplied with approx. 6 kPa, while<br />

pore water samplers in silt and loam<br />

are supplied with 10 to 30 kPa. As<br />

clay soils retain water even at higher<br />

tensions a vacuum from 30 to 85 kPa<br />

could be applicable.<br />

VacuPorter vacuum case<br />

Applications<br />

For qualitative analysis of soil<br />

water<br />

Benefits<br />

Low cost<br />

Easy handling<br />

Limits<br />

Discontinuous sampling<br />

Undefined sampling<br />

Tools<br />

Pore water samplers<br />

Hand-operated vacuum floor pump<br />

VPS-2 or portable vacuum case<br />

VacuPorter<br />

Applications<br />

Long term monitoring projects<br />

Studies on leachate<br />

Soil water extraction from a certain<br />

pore size with a vacuum which is<br />

exactly suitable to the pore size.<br />

Benefits<br />

Defined sampling<br />

Limits<br />

Constant vacuum ignores changing<br />

soil water tensions<br />

Tools<br />

Pore water or leachate samplers<br />

Vacuum station VS without<br />

controlling Tensiometer<br />

Typical soil water sampling system<br />

including samplers, connecting tubes,<br />

sampling bottles and a vacuum unit<br />

Benefits<br />

Constant sorption and constant<br />

filter effects<br />

Prevents memory effects<br />

Limits<br />

Takes samples from various pore<br />

sizes depending on the current<br />

vacuum<br />

Tools<br />

Pore water or leachate samplers<br />

Vacuum station VS with controlling<br />

Tensiometer<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

17


Pore water sampling<br />

SK20<br />

Shaft:<br />

Ø 20 mm; acrylic<br />

Porous ceramic: Ø 20 mm; length 60 mm<br />

Bubble point: 1 bar<br />

Suction tube: PE; Øi 1.6 mm; Øo 2.8mm<br />

Protective tube: PVC; Ø 11 mm<br />

Item<br />

SK20<br />

SIC20<br />

(SK20 identical with former type SKP100)<br />

Art.no.<br />

SK20-.../...<br />

Indicate required shaft and tube length<br />

on an order, e. g. 30 cm shaft and 5 m<br />

tube = SK20-30/5<br />

<strong>UMS</strong> SiC cups are protected by<br />

utility model no. 20 2005 002 598.4<br />

Shaft:<br />

Ø 20 mm; acrylic<br />

SiC cup: Ø 20 mm; length 60 mm<br />

Bubble point: 0.9 bar<br />

Suction tube: PE; Øi 1.6 mm; Øo 2.8mm<br />

Protective tube: Ø 11 mm, fabric enforced<br />

Item<br />

SIC20<br />

Art.no.<br />

SIC20-.../...<br />

SK20 pore water sampler with<br />

removable shaft. For continuous and<br />

discontinuous extraction. Suitable for<br />

determination of nitrate and common<br />

organic and inorganic substances.<br />

Applications<br />

Continuous extraction<br />

Discontinuous extraction<br />

Nitrate, chloride, sulphate, calcium,<br />

sodium, ammonium, phosphorus<br />

Benefits<br />

Very low dead volume<br />

Shaft and cup exchangeable<br />

pH range of 4 to 9<br />

Limits<br />

Not suitable for heavy metals<br />

Pore water sampler SIC20 with<br />

removable shaft like the SK20, but<br />

with a SiC silicon carbide cup instead<br />

of the ceramic cup. SiC is sintered at<br />

2500°C and is chemically much more<br />

passive than ceramic or borosilicate.<br />

The bubble point 90 kPa.<br />

Applications<br />

Continuous extraction<br />

Disontinuous extraction<br />

Benefits<br />

High permeability<br />

Low sorption<br />

Very low dead volume<br />

Shaft and cup exchangeable<br />

Indicate required shaft and tube length<br />

on an order, e. g. 30 cm shaft and 5 m<br />

tube = SIC20-30/5<br />

SKPE25<br />

Shaft:<br />

Ø 25 mm; acrylic<br />

Porous ceramic: Ø 24 mm; length 60 mm<br />

Bubble point: 1 bar<br />

Suction tube: PE; Øi 2 mm; Øo 4 mm<br />

Protective tube: PVC; Ø 11 mm<br />

Item<br />

SKPE25<br />

Art.no.<br />

SKPE25-.../...<br />

Indicate required shaft and tube length<br />

on an order, e. g. 30cm shaft and 5m<br />

tube = SKPE25-30/5<br />

The sampled solution is stored inside<br />

the shaft and is collected by applying<br />

a pressure to the additional tube.<br />

Applications<br />

For extraction of soil solution from<br />

depths down to 8 meters<br />

Benefits<br />

Cost effective as sampling bottles<br />

are not needed<br />

The extracted soil water is stored<br />

at soil temperature<br />

pH range 4 to 9<br />

Limits<br />

Not suitable for heavy metals<br />

18 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Instead of a ceramic cup the SPE20<br />

pore water sampler has a porous PEnylon-membrane<br />

which is specially<br />

suitable for heavy metals and whenever<br />

ceramics are inappropriate.<br />

Applications<br />

For detection of herbicide,<br />

pesticide, heavy metals<br />

Benefits<br />

Only materials with sample contact<br />

are nylon and polyethylene<br />

Low sorption<br />

Limits<br />

Bubble point is 100 kPa, but the<br />

porous PE cover allows water to<br />

flow only up to 20 kPa<br />

Pore water sampler with porous<br />

borosilicate glass cup. Borosilicate is<br />

suitable for phosphate and DOC.<br />

Available with a diameter of 20 mm<br />

or 25 mm.<br />

Applications<br />

Determination of phosphate,<br />

DOC<br />

Limits<br />

Because of complex chemical<br />

interactions sorption effects should<br />

be evaluated.<br />

SPE20<br />

Shaft:<br />

Ø20 mm; acrylic<br />

PE-nylon cup: Ø20 mm; length 60 mm<br />

Bubble point: 1 bar<br />

Suction tube: PE; Øi 1,6 mm; Øo 2,8mm<br />

Protective tube: PVC; Ø 11 mm<br />

Item<br />

SPE20<br />

Shaft:<br />

Glass cup:<br />

Bubble point:<br />

Suction tube:<br />

Item<br />

SG20<br />

SG25<br />

Art.no.<br />

SPE20-.../...<br />

Indicate required shaft and tube length<br />

on an order, e. g. 30 cm shaft and 5 m<br />

tube = SPE20-30/5<br />

SG25<br />

Ø20 or 25 mm; acrylic<br />

Ø20 or Ø25 mm<br />

Length 60 mm<br />

1 bar<br />

Teflon; Øi 1.5 mm;<br />

Øo 2.8 mm<br />

Art.no.<br />

SG20-.../...<br />

SG25-.../...<br />

Pore water sampling<br />

Indicate required shaft and tube length<br />

on an order, e. g. 30 cm shaft and 5 m<br />

tube = SG20-30/5<br />

Sampler made of silicon carbide with<br />

bubble point 10 kPa. SiC is sintered at<br />

2500°C and is chemically much more<br />

passive than ceramic or borosilicate.<br />

Please ask for <strong>UMS</strong>‘s<br />

suitability survey.<br />

Applications<br />

Leachate sampling<br />

Sampler rake in lysimeter sites<br />

Benefits<br />

High permeability<br />

Low sorption<br />

Limits<br />

Only suitable for up to 10 kPa, i. e.<br />

only for leachate sampling<br />

No shaft attached<br />

<strong>UMS</strong> SiC cups are protected by<br />

utility model no. 20 2005 002 598.4<br />

SiC40 cup:<br />

Bubble point:<br />

Suction tube:<br />

Item<br />

SIC40<br />

Ø 40; length 500 mm<br />

0.1 bar<br />

Øi 4 mm; Øo 6 mm<br />

Art.no.<br />

SIC40/...<br />

Indicate required tube length on an<br />

order, e. g. 5 m tube = SIC40/5<br />

SIC40<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

19


Leachate sampling<br />

SPG120<br />

Pore water sampling and leachate monitoring<br />

Leachate sampling should be<br />

done below root zone and where<br />

only downwards leachate water is<br />

expected.<br />

The dimension of your sampler<br />

correlates to the soil. A homogenous<br />

Diameter:<br />

Ø 120 mm<br />

Thickness: 9 mm ± 1 mm<br />

Suction tube: Teflon; Ø1/16“x Ø 1/8<br />

Tube length: 2 m<br />

Item<br />

Porous glass plate<br />

Art.no.<br />

SPG120<br />

sandy soil needs small surface, a<br />

gravel heterogeneous soil with bypass<br />

and interflow requires big surface.<br />

Further the height of the wall depends<br />

on the soil and expected tensions, and<br />

the accuracy of the applied vacuum.<br />

SPG120 leachate sampling plate made<br />

of porous borosilicate glass.<br />

Suitable for phosphate and DOC.<br />

Applications<br />

Leachate sampler<br />

Benefits<br />

Extracts solution from the top as<br />

well as from bottom side<br />

No sealing foil or housing is needed<br />

as the tube is fitted into a hole which<br />

ends in the plate’s centre<br />

Optionally available with rubber foil<br />

backing<br />

The higher the wall, the lower are<br />

errors in under- or over estimating of<br />

leachate water, caused by sucking<br />

from outside area or false flow from<br />

sampler surface into the surrounding<br />

soil.<br />

SIC300<br />

Porous silicon carbide suction plate<br />

for laboratory use or field leachate<br />

sampling. The plate is covered with<br />

a butyl rubber foil and a bottom pipe<br />

connector to apply 6 kPa vacuum.<br />

Bubble point 10 kPa.<br />

Diameter:<br />

Ø 300 mm<br />

Thickness:<br />

10 mm<br />

Saturated conductivity: 1.2 x 10 -4 cm/sec<br />

Applications<br />

Suitable for lysimeter use, laboratory<br />

or in-situ applications<br />

Item<br />

Porous SiC plate<br />

Art.no.<br />

SIC300<br />

KL2<br />

The leachate bucket can be buried<br />

in situ to collect leachate - or can be<br />

used as a laboratory soil pillar and<br />

lysimeter.<br />

On the bottom of the stain less steel<br />

bucket a 1 bar high flow ceramic plate<br />

is fixed. The suction tube has contact<br />

only to the “backside“ of the ceramic<br />

plate’s rubber backing.<br />

Diameter: 300 mm<br />

Available heights: 300 mm<br />

600 mm<br />

1200 mm<br />

Ceramic plate: 0.5 bar high flow<br />

Flow rate : 2 litres per hour at 2 kPa<br />

(approx. 28 mm/h)<br />

Material: 2 mm stainless steel<br />

Applications<br />

Buriable leachate sampler<br />

Laboratory soil pillar<br />

Item<br />

height 300 mm<br />

height 600 mm<br />

height 1200 mm<br />

Art.no.<br />

KL2-300<br />

KL2-600<br />

KL2-1200<br />

20 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Max. vacuum:<br />

Max. pressure:<br />

Capacity:<br />

Battery capacity:<br />

Case:<br />

Weight:<br />

Attachment KIPP 010<br />

VacuPorter<br />

Light-weight, portable, non regulated<br />

vacuum case with internal pump for<br />

creating vacuum from 0 to 85 kPa or<br />

pressure up to 4 bars.<br />

Item<br />

Vacuum case<br />

Art.no.<br />

VacuPorter<br />

85 kPa at 1 bar atm.<br />

4 bar<br />

10 liters / minute<br />

7 hours operation<br />

30 x 25 x 13 cm<br />

4,8 kg<br />

VPS-2<br />

Extremely rugged hand-operated<br />

vacuum floor pump with large swept<br />

volume for easy evacuation of<br />

sampling bottles in the field.<br />

Evacuation of sampling bottle<br />

Collecting soil water solution from<br />

sampling bottles<br />

Item<br />

Floor pump<br />

Max. vacuum:<br />

Capacity:<br />

The tipping counter measures water<br />

flows of up to 5 litres per minute with<br />

a resolution of 100 ml. With adequate<br />

connections the system is sealed<br />

hermetically and vacuum tight.<br />

Each tipping is counted by a reed<br />

switch which is fitted with a 1,5 m<br />

long cable with plug. Connecting<br />

cables CC-4 are available in different<br />

lengths.<br />

As an accessory an additional tipping<br />

cup with resolution 10 ml per count<br />

can attached on top.<br />

Benefits<br />

Suitable for vacuum applications<br />

Slide-in separator with bottle for<br />

sampling 2.5% of the flow volume<br />

Limits<br />

Art.no.<br />

xxxx<br />

VPS-2<br />

xxxx<br />

xxxx<br />

xxxx -85 kPa at 1 bar atm.<br />

0.41 liters per stroke<br />

KIPP100<br />

Applications<br />

Tipping counter for flow rates,<br />

discharge, leachate measurements<br />

Signal:<br />

Reed switch<br />

Max. flow: 5 litres per minute<br />

Resolution: 100 ml per count<br />

Accuracy:<br />

1% at 1 litre/h<br />

Enclosure material: UDEL PSU<br />

Wall fixture: Aluminium<br />

Sampling bottle: Polyethylene<br />

Item<br />

Art.no.<br />

Tipping counter KIPP100<br />

10 ml attachment KIPP010<br />

Leachate sampling<br />

Sampling bottles SF-box Tanks<br />

Soil water sampling bottles made of<br />

Duran glass, available in three sizes.<br />

Implosion proof<br />

Plastic coating as chip guard<br />

Silicone rubber gasket with two<br />

connectors<br />

Accessory: Clip for upright<br />

attachment on walls<br />

In the sampling bottle box up to 6<br />

sampling bottles can be stored. The<br />

lid is covered with isolating material.<br />

Latches shut the box securely. The<br />

suction tubes are led through sealed<br />

fittings on the side of the box.<br />

Size 40 x 30 x 28 cm<br />

Material: PVC<br />

Stainless steel vacuum tanks for<br />

leachate water sampling or as a<br />

vacuum buffer. Pressure range from<br />

-1 to +1 bar. Available in three volumes<br />

with 20, 30 or 50 liters. Incl. pressure<br />

gauge, 8 mm SMC-quick-lock tube<br />

connector and visual indicator for fill<br />

level.<br />

Item<br />

Art.no.<br />

500 ml bottle SF-500<br />

1000 ml bottle SF-1000<br />

2000 ml bottle SF-2000<br />

Wall clip<br />

SF-CLIP<br />

Item<br />

Box with lid<br />

Art.no.<br />

SF-BOX<br />

Volume<br />

Art.no.<br />

20 liters VT20<br />

30 liters VT30<br />

50 liters VT50<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

21


Vacuum systems<br />

Soil water sampling with vacuum systems<br />

Extract representative soil water<br />

samples with a constant vacuum, a<br />

timed vacuum or a tension-controlled<br />

vacuum: with the new VS-systems<br />

we can offer you an all-purpose and<br />

modern vacuum regulation.<br />

The VS product range replaces all<br />

previous <strong>UMS</strong> vacuum stations like<br />

the VK-3 case, the SCS7 and the<br />

SCS8.<br />

As a system solution all units now<br />

incorporate a vacuum pump, sensors<br />

and processor controlled regulation,<br />

suitable for battery powered in-thefiled<br />

use.<br />

1 or 2 regulated vacuum outputs<br />

The VS-single supplies one adjustable<br />

vacuum, either with a fixed constant<br />

value or controlled by a connected<br />

Tensiometer.<br />

For taking samples for example in<br />

the root zone or leachate water both<br />

models VS-twin and VS-pro offer<br />

two vacuum outputs which can be<br />

adjusted to a differing setting.<br />

Tension controlled sampling<br />

A Tensiometer measures the soil water<br />

tension. The vacuum automatically<br />

is set in correspondence to the<br />

measured tension. The advantage<br />

of this method is that the negative<br />

pressure potential which draws on<br />

the soil water is always constant<br />

(or in an adjustable proportion)<br />

and therefore, can be set to a low<br />

value. Thus, the soil water balance<br />

is disturbed as little as possible by<br />

a constant effective potential (i. e. =<br />

difference between vacuum in the<br />

sampler and the soil water tension).<br />

At any time the sampling takes place<br />

under defined conditions. Filtration<br />

and sorption processes on the cup<br />

are constant, memory effects are<br />

more or less excluded.<br />

The figure shows a possible set-up of a VS controlled sampling site<br />

Easy set-up<br />

Configuration and data download<br />

are done with a graphic Windows<br />

interface. The VS-pro additionally has<br />

a graphic LC-display and keypad for<br />

setting the most important functions<br />

of the unit, and where readings and<br />

status are displayed continuously.<br />

Rain<br />

event<br />

Multiple configuration options<br />

All VS units allows many possible<br />

configurations options, like setting<br />

accuracy, intervals and behaviour of<br />

regulation, hysteresis etc.<br />

As a controlling Tensiometer use any<br />

<strong>UMS</strong> Tensiometer with 4 pin plug,<br />

e. g. the T4 or T5, or a T8 with 8-pin<br />

plug.<br />

Integrated timer<br />

A timer was integrated to allow<br />

sampling in intervals. The vacuum is<br />

only established within the selected<br />

time range. At other times the<br />

pressure difference between soil<br />

water tension and vacuum is set to<br />

zero. This reduces the disturbance of<br />

the soil water balance.<br />

Automated measurements and<br />

logging<br />

The vacuum as well as an optionally<br />

connected Tensiometer are<br />

continuously measured. The readings<br />

are stored in a ring buffer and can be<br />

downloaded to a PC.<br />

The signals of Tensiometer and<br />

vacuum sensor can be measured on<br />

two analogue outputs.<br />

Example for a tension controlled vacuum<br />

Contact VS<br />

Andreas Steins<br />

Tel.: +49 (0) 89 / 12 66 52 - 18<br />

eMail: as@ums-muc.de<br />

22 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Item<br />

VS with one<br />

vacuum output<br />

VS with two<br />

vacuum outputs<br />

Art.no.<br />

VS-single<br />

VS-twin<br />

Vacuum unit with one or two vacuum<br />

outputs, for constant or tension<br />

controlled vacuum.<br />

Applications<br />

Long term monitoring<br />

Soil water extraction under defined<br />

conditions<br />

Leachate measurements under<br />

defined conditions<br />

Lysimeter sites<br />

Benefits<br />

Vacuum pump with high accuracy<br />

Two vacuum outputs<br />

Selectable constant or tension<br />

controlled vacuum<br />

Status indicated by multicolor LED<br />

Optimised for rechargeable battery<br />

supply<br />

One Tensiometer connectable: T8,<br />

T4 or T5<br />

Multiple configuration options<br />

Integrated data logger<br />

Limits<br />

Configuration only by PC or Laptop<br />

VS<br />

Supply:<br />

10.5 ...15 VDC<br />

Current consumption<br />

Operating average: approx. 15 mA<br />

Standby: approx. 1 mA<br />

While regulating: 50 ... 800 mA<br />

Interface:<br />

tensioLINK, RS485<br />

Analog output: 2 x 0 ... 1V, ... 2V, ... 5V<br />

Vacuum regulation<br />

Range:<br />

0 ... -85 kPa<br />

Accuracy: ±0.05 kPa<br />

Memory:<br />

5000 readings<br />

Dimensions: 260 x 160 x 100 mm<br />

Protective rate: IP 66<br />

Operating temp.: -10°C ... +45°C<br />

Enclosure: Aluminium<br />

Vacuum systems<br />

Vacuum unit with one or two vacuum<br />

outputs, for constant or tension<br />

controlled vacuum. With keypad and<br />

display for basic status check and<br />

configuration.<br />

VS-pro<br />

Applications<br />

Long term monitoring<br />

Defined pore water sampling<br />

Defined leachate measurements<br />

Lysimeter sites<br />

Item<br />

Art.no.<br />

VS with display and<br />

two vacuum outputs VS-pro<br />

Benefits<br />

Display and keypad for basic status<br />

check and configuration<br />

Continuous display of readings and<br />

status on the LCD<br />

LCD backlight and multicolor LED<br />

Vacuum pump with high accuracy<br />

Two vacuum outputs<br />

Selectable constant or tension<br />

controlled vacuum<br />

Optimised for rechargeable battery<br />

supply<br />

One Tensiometer connectable: T8,<br />

T4 or T5<br />

Multiple configuration options<br />

Integrated data logger<br />

Supply:<br />

10.5 ...15 VDC<br />

Current consumption<br />

Operating average: ca. 16 mA<br />

Standby: ca. 2 mA<br />

While regulating: 50 ... 800 mA<br />

Interface:<br />

tensioLINK, RS485<br />

Analog output: 2 x 0 ... 1V, ... 2V, ... 5V<br />

Vacuum regulation<br />

Range:<br />

0 ... -85 kPa<br />

Accuracy: ±0.05 kPa<br />

Memory:<br />

5000 readings<br />

Dimensions: 260 x 160 x 100 mm<br />

Protective rate: IP 66<br />

Operating temp.: -10°C ... +45°C<br />

Enclosure: Aluminium<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

23


Soil chemistry<br />

BaPS Barometric Process Separation<br />

The Barometric Process Separation (BaPS) is a patented method for the determination of primary microbial carbon and<br />

nitrogen conversion processes in undisturbed soil samples.<br />

Simultaneous measurement<br />

With the BaPS system the following<br />

conversion processes can be<br />

determined simultaneously:<br />

Gross nitrification<br />

Gross denitrification<br />

Soil respiration rate<br />

Benefits<br />

Analysis of undisturbed soil<br />

samples<br />

No application of tracers<br />

No use of inhibitors required<br />

Easy handling and prompt results<br />

Low initial and maintenance costs<br />

Good traceability as calculation<br />

algorithms are visible<br />

Ordering Information<br />

Art. No.<br />

Nitrogen cycle in soils<br />

The measuring principle<br />

Gross nitrification, gross denitrification<br />

and soil respiration rates are<br />

determined by recording air pressure,<br />

O2 and CO2 net balances within a<br />

gas and pressure tight isothermal<br />

system.<br />

Decisive are microbial activities<br />

causing an increase of pressure and<br />

carbon dioxide, and a decrease of<br />

oxygen.<br />

Soil respiration is pressure neutral:<br />

CH 2<br />

O + O 2,Atm<br />

CO 2,Atm<br />

+ H 2<br />

O<br />

Nitrification causes a pressure decrease:<br />

+ -<br />

NH 4<br />

+ 2O 2,Ni<br />

t NO 3<br />

+ H 2<br />

O + 2H +<br />

Denitrification causes a pressure increase:<br />

-<br />

5CH 2<br />

O + 4NO 3<br />

+ 4H + 5CO 2,Den<br />

+ 7H 2<br />

O + 2N 2<br />

Further, the dynamic equilibrium of the CO2- and O2- concentration in the head<br />

space and in the aqueous phase as well the pH-depending solubility of CO2<br />

must be considered.<br />

Applications<br />

Nitrate release<br />

Nitrogen emission<br />

Optimising N-fertilizer usage<br />

Parameterization of microbial<br />

N-conversion processes<br />

Soil respiration activity<br />

System limits<br />

Analysis of anaerobic soil is not<br />

possible, as in anaerobic soil other<br />

processes occur, such as the<br />

development of Methane.<br />

Sales and technical support<br />

Thomas Pertassek<br />

Tel.: +49 (0) 89 / 12 66 52 - 17<br />

eMail: tp@ums-muc.de<br />

Parameterisation of microbial N-<br />

conversion processes<br />

Scientific contact at IFU-IMK<br />

Dr. Klaus Butterbach-Bahl<br />

Tel.: +49 (0) 8821 / 183- 136<br />

klaus.butterbach@imk.fzk.de<br />

Developed in co-operation with<br />

the Forschungszentrum Karlsruhe Institute IFU-IMK<br />

24 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


The system consists of the incubator, the sensor top with integrated septum,<br />

oxygen, carbon dioxide, pressure and temperature sensor, the external<br />

electronic interface and the Windows software for control and data analysis.<br />

BaPS<br />

Carbon dioxide sensor<br />

Measuring range: 0 ... 3 vol%<br />

Rel. accuracy: ±2%<br />

Oxygen sensor<br />

Measuring range: 15 ... 21 vol%<br />

Rel. accuracy: ±1%<br />

Pressure sensor<br />

Measuring range: 80 ... 120 kPa<br />

Rel. accuracy: ±0.1%<br />

Temperature sensor<br />

Measuring range: -30 ... 70 °C<br />

Accuracy: 0.1°C by 0°C<br />

Dimensions<br />

Electronic interface: 260 x 260 x 16 mm<br />

Incubator:<br />

Ø 220 x 67 mm<br />

Sensor top:<br />

Ø 220 x 20 mm<br />

Soil chemistry<br />

Soil Sample Rings Volume Amount Art.no.<br />

53 x 50 mm, h 51 mm 100 ml 7 BaPS 100-S<br />

60 x 56 mm, h 40.5 mm 100 ml 7 BaPS 100-U<br />

84 x 80 mm, h 50 mm 250 ml 3 BaPS 250<br />

Additionally required: thermostat or<br />

a water bath with a temperature<br />

constancy of ± 0,01 K and a<br />

standard PC with RS232 interface<br />

THERMO-UM Sample ring set Soil gas lance<br />

The space-saving THERMO-UM is a<br />

circulation thermostat optimized for<br />

the temperature regulation of the<br />

BaPS system.<br />

Application<br />

External temperature control of the<br />

BaPS incubation chamber<br />

Benefits<br />

Accurate and precise<br />

Connector for an external control<br />

temperature probe<br />

RS 232C interface<br />

The <strong>UMS</strong> soil gas lance is suitable<br />

for extraction of soil gas in<br />

unsaturated and partially saturated<br />

zones.<br />

The gas is drawn up through<br />

hydrophobic porous Teflon. Thus,<br />

soil substratum, contaminations<br />

or water cannot intrude.<br />

Specifications<br />

Diameter: 8 mm<br />

Total length: 500 mm<br />

Porous length: 2 x 50 mm<br />

Connector: Swagelok ® ¼“<br />

The soil sample sets are optimized for<br />

the BaPS system. They can be used<br />

to take samples in virtually all soils.<br />

The samples can be taken from the<br />

surface down to a depth of 2 m, in<br />

auger holes or in profile pits, above<br />

as well as under the ground water<br />

level. The closed ring holder in this<br />

set is fitted with a conical threaded<br />

connection which means that the<br />

ring holder may also be hammered<br />

into the soil with an impact absorbing<br />

hammer.<br />

Item<br />

THERMO-UM<br />

Art.no.<br />

THERMO-UM<br />

Item<br />

for BaPS 100-S<br />

for BaPS 100-U<br />

for BaPS 250<br />

Art.no.<br />

bpe.07.60.SC<br />

bpe.07.53.SC<br />

bpe.03.84.SC<br />

Item<br />

Soil gas lance<br />

Art.no.<br />

BGL-100<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

25


Dendrometers<br />

D1<br />

Permanent tree-girth tape-measure<br />

with diameter scale<br />

Application<br />

Direct manual reading of the<br />

diameter of trees<br />

Dimensions: 2100 x 15 x 0,5 mm<br />

Thermal elongation: 75 x 10 -6 / K<br />

Coefficient of friction: 0.5 on dry bark<br />

Scale division: 0.05 πcm<br />

Vernier scale: 0.01 πcm<br />

Benefits<br />

Easy, quick and non-invasive<br />

installation<br />

Scale already shows diameter<br />

Vernier for accurate readings<br />

Minimised friction<br />

Low thermal expansion<br />

For larger trunks two bands can be<br />

connected<br />

Printed “Do not touch“ warning in<br />

several languages<br />

Short spring for diameters less than<br />

40 cm, long spring for diameters<br />

40 ... 65 cm or connected bands.<br />

Item<br />

Tree-girth tape:<br />

With short spring<br />

With short spring<br />

Art.no.<br />

D1-K<br />

D1-L<br />

D6<br />

Sensor:<br />

Bridge resistance:<br />

Measuring range:<br />

Power supply:<br />

Strain gage based tree growthsensor<br />

Applications<br />

Continuous high-resolution<br />

measuring of daily circumferential<br />

variation of trunks<br />

DMS<br />

350 Ohm<br />

0 .. 50 mm growth<br />

5 ... 15 VDC, stabilised<br />

Benefits<br />

Non-invasive installation<br />

No disturbance of growth<br />

Measuring of daily changes and<br />

immediate reactions, e. g. to rain<br />

or sunrise<br />

Minimisation of the friction<br />

on the bark with Teflon layer<br />

Invar steel girth cable with<br />

minimal dependence on<br />

temperature<br />

Measuring range expandable by<br />

adjusting of the cable<br />

Limits<br />

Strain-gage caused measuring<br />

complexity<br />

Item<br />

Art.no.<br />

Dendrometer D6<br />

Required accessories:<br />

Invar girth cable: order per meter<br />

Teflon bark layer: order per meter<br />

<strong>Product</strong> information, system solutions and reference projects ...<br />

... always up-to-date on our webpage:<br />

www.ums-muc.de<br />

26 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Complete weather stations - custom-made by <strong>UMS</strong><br />

Weather data is important for many<br />

research tasks like meteorology,<br />

climate science, crop disease and<br />

pest forecast and last but not least<br />

for soil & hydrological studies.<br />

Water and energy balances are<br />

associated by the current evaporation<br />

of the plants and the transpiration of the<br />

soil. Thus, the knowledge of drainage,<br />

precipitation and evapotranspiration<br />

is essential for hydrologic predictions,<br />

water balance studies and water<br />

resource management.<br />

Climate<br />

Example for 10 m inclinable mast<br />

Please contact us or your local dealer<br />

for more information or a detailed<br />

offer.<br />

<strong>UMS</strong> weather stations<br />

<strong>UMS</strong> supplies custom-made stations<br />

in accordance with your targets and<br />

requirements.<br />

A typical station includes sensors for<br />

Air humidity and temperature<br />

Wind speed<br />

Precipitation<br />

Global radiation<br />

Air pressure<br />

<strong>UMS</strong> weather stations incorporate<br />

climatic sensor of well-known<br />

suppliers and fulfil WMO standards.<br />

To be complete a station requires:<br />

Mast with sensor mounts, foot<br />

(also portable), crossbeam<br />

Outdoor enclosure<br />

Datalogger<br />

Example for 2 m mast<br />

Power supply, e. g. solar<br />

Lightning protection<br />

Collecting<br />

funnel<br />

Inlay filter<br />

funnel with<br />

leaf catcher<br />

and<br />

fine filter tube<br />

PE-sampling<br />

bottle<br />

Rain sampler type LWF with collecting<br />

funnel, sampling bottle and effective<br />

filtering. The RS200 was developed<br />

by the LWF Bavarian State Institute of<br />

Forestry and fulfils recommendations of<br />

the World Meteorological Organization<br />

(WMO).<br />

The WMO recommends to add rain<br />

sampler like the RS200 to compensate<br />

the principle error of tipping bucket rain<br />

gauges. As precipitation varies in an<br />

area four RS200 units per rain gauge<br />

are advisable.<br />

Applications<br />

For quantitative and analytical<br />

surveys on precipitation<br />

Benefits<br />

HDPE and PP material for easy<br />

cleaning and undisturbed analysis<br />

Effective filtering<br />

Minimised rain loss by evaporation<br />

Filter kit<br />

The special filter kit includes a coarsely<br />

meshed sieve and an inlay funnel with<br />

fine filter nozzle which is additionally<br />

placed inside the collecting funnel.<br />

This prevents that needles or foliage<br />

enter the bottle - but still the loss of<br />

rain by evaporation is minimised as the<br />

adhesion of drops is reduced.<br />

Photo: Option with pipe stand which<br />

is partially buried for positioning the<br />

sampling funnel in a height of 1 m.<br />

Option: D-rs200: Inside the pipe the<br />

bottle is lowered into the ground, so<br />

the sampled rain can be stored at soil<br />

temperature.<br />

The accessory bird scarecrow ring is<br />

attached to the funnel.<br />

Diameter:<br />

200 mm<br />

Funnel surface: 314 cm 2<br />

Material:<br />

HDPE and PP<br />

Item<br />

Rain sampler, 5 l<br />

Rain sampler, 4.4 l<br />

Spare filter kit<br />

Pipe stand<br />

Anti bird ring<br />

Lid & tube set for<br />

soil temp storage<br />

Art.no.<br />

RS200/5<br />

RS200/4.4<br />

rs200.FS<br />

rs200.S100<br />

rs200.V<br />

D-rs200<br />

RS200<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

27


Soil temperature<br />

Th2<br />

Measuring range -50°C...+70°C<br />

Accuracy ±0,1 K at 0°C<br />

±0,2 K at ± 20°C<br />

±0,1 K at ± 40°C<br />

Sensitive span Length 15 mm ,Ø 5 mm<br />

Sensor position 10 mm from tip<br />

Casing of tip Stainless steel, IP68<br />

Dimensions Length 80 mm, Ø 6 mm<br />

Cable length 10 m<br />

Benefits<br />

Highest accuracy<br />

Minimised soil disturbance<br />

Punctual temperature<br />

pick-up<br />

Maintenance-free and<br />

durable<br />

Cable strain-relieved<br />

Three temperature sensor<br />

types available<br />

Available sensor types:<br />

Pt100<br />

Standard 4-wire probe<br />

For cable lengths up to 200 m<br />

Linear signal output<br />

Thermistor<br />

3-wire connection for data logger<br />

applications<br />

Non linear but high-resolution<br />

output<br />

Excellent long-term stability<br />

Cable length max. 40 m<br />

Pt1000<br />

3-wire but with linear output<br />

Cable length max. 20 m<br />

Th2 Soil temperature probe<br />

The durable, water proof temperature<br />

probe for soils, fluids, gases.<br />

The thin body and sharpened tip<br />

reduce the soil disturbance when<br />

installed and ensures a good thermal<br />

contact to the soil. A heat conducting<br />

filling inside improves the thermal<br />

conductivity from the casing to the<br />

probe - for a fast response punctual<br />

temperature pick-up and minimised<br />

cable temperature influence.<br />

Item<br />

with Pt100 1/3 B<br />

with Thermistor<br />

with Pt1000 1/3 B<br />

Art.no.<br />

Th2-h<br />

Th2-f<br />

Th2-t<br />

Th3<br />

Soil Temperature Profile Probe to<br />

measure the temperature profile in<br />

soils in the depths 5, 10, 20, 30, 50<br />

and 100 cm.<br />

Inside a tube made of glass-fibre<br />

reinforced plastic 6 temperature<br />

sensor elements are placed in<br />

different depths. Each sensor element<br />

has direct contact to a stainless steel<br />

ring which ensures that each sensor<br />

has direct contact to the soil.<br />

Measuring range -20°C...+50°C<br />

Accuracy ±0,1 K<br />

Resolution 0,034°C<br />

Output signal 6 x 0...1 V<br />

Supply 6 ... 18 VDC<br />

Dimensions Length 102 cm, Ø2 cm<br />

Cable<br />

Length 1,5 m, 8-pin plug<br />

M12, strain-relieved, with<br />

plastic protection tub<br />

Tube<br />

GRP glass-fibre reinforced<br />

plastic, embedded stainless<br />

steel rings, conical tip<br />

Options Probe with SDI-12 output<br />

and 4-pin plug M12<br />

Benefits<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Get a temperature profile<br />

with only one probe<br />

6 analogue signals 0 ... 1 V<br />

Optionally with SDI-12<br />

Minimised soil disturbance<br />

Probe and cable completely<br />

buried, thus no influence of<br />

the ambient temperature<br />

Punctiform temperature pick-up<br />

Excellent thermal contact through<br />

thin-walled stainless steel rings<br />

Robust and maintenance free<br />

Item<br />

Probe with 6x0...1V<br />

Probe with SDI-12<br />

Art.no.<br />

Th3-v<br />

Th3-sdi12<br />

Limits<br />

–<br />

–<br />

–<br />

Not for spot measurements<br />

Only for data logger connection<br />

The depths are fix and<br />

cannot be changed<br />

28 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Laboratory evaporation method for the determination of<br />

pF-curves and unsaturated conductivity<br />

The evaporation method according<br />

to Wind/Schindler is a simple and<br />

fast technique to determine retention<br />

curves of soil samples in standard 250<br />

ml soil sampling rings. The unsaturated<br />

Benefits<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

–<br />

Simple and flexible handling<br />

Low time and cost expenditure<br />

Expandable<br />

Small size for easy transportation<br />

The water retention curve is<br />

determined with high quality even<br />

close to saturation<br />

The hydraulic functions are reliably<br />

assured by the large number of<br />

taken readings<br />

Simultaneous and accurate<br />

measurement of water retention<br />

curve and hydraulic conductivity<br />

Suitable for all soils (as long as<br />

Tensiometers can be installed)<br />

No special requirements for the<br />

measuring location beside possibly<br />

constant evaporation conditions<br />

during a measurement<br />

conductivity is determined by<br />

measuring the soil water tension<br />

with miniature Tensiometers in two<br />

levels inside the sample, and then<br />

correlated to the soil water tension or<br />

the moisture content.<br />

Durner and Peters developed the<br />

robust correlation procedure to link<br />

the hydraulic functions (SHYPFIT<br />

2.0, Peters and Durner, 2006b). The<br />

data is fitted to a selectable standard<br />

model, i. e. van Genuchten/Mualem,<br />

bimodal van Genuchten/Mualem<br />

or Brooks and Corey. The Model<br />

parameters can be set before, during<br />

or after a measuring procedure. Thus,<br />

the results are verified and the values<br />

for dry range and saturation are<br />

calculated according to the selected<br />

model.<br />

Limits<br />

– The operating range is limited<br />

to the measuring range of the<br />

Tensiometers<br />

– Poor resolution of the hydraulic<br />

conductivity near saturation<br />

(especially in sandy soils)<br />

Execute a measurement<br />

If a sample unit is placed on the scale<br />

the software automatically starts the<br />

weighing menu.<br />

If more than one sample is tested<br />

at a time each sample is placed on<br />

the scale in turn, for example twice<br />

a day. The software automatically<br />

recognizes each sample unit and<br />

stores the weight in correlation to this<br />

sample. A maximum of 20 samples<br />

can be tested simultaneously.<br />

Independent from the weighing the<br />

soil water tensions are automatically<br />

measured. Pressure transducers and<br />

electronics are housed in the sensor<br />

unit, and all sensor units are linked<br />

with the tensioLINK bus to your PC<br />

for continuous logging of the soil<br />

water tension.<br />

Hyprop<br />

The advantage compared to other<br />

methods is that the hydraulic<br />

properties are determined during a<br />

natural drying process of the soil.<br />

Hyprop’s outstanding features are<br />

the simple handling and the modular<br />

setup. For a start up you just need<br />

the HYPROP starter set and a scale.<br />

Existing laboratory scales, minimum<br />

requirements are a serial connection<br />

and a measuring range of 2000 grams,<br />

can be integrated. This set can be<br />

extended to up to 20 sample units.<br />

Together with the correlation<br />

procedure you get a truly practical<br />

method which offers extraordinary<br />

results in the determination of<br />

hydraulic functions with low<br />

measuring expenditure.<br />

Content of supply<br />

Basic starter kit Hyprop-S<br />

– Tool case with USB-adapter,<br />

software, connecting cable, auger<br />

positioning device, Tensiometer<br />

auger, refilling tools, 2 silicone<br />

gaskets, 1 sampling ring Euronorm<br />

250 ml<br />

– Sensor unit in case, with T-connector,<br />

connecting cable, degassing<br />

attachment, 2 Tensiometer cups,<br />

saturation bowl<br />

Starter kit Hyprop-SW<br />

– as Hyprop-S but including a precision<br />

scale (2000 g range; 0,1 gram<br />

resolution)<br />

Extension kit Hyprop-E<br />

– Sensor unit in case, with T-connector,<br />

connecting cable, degassing<br />

attachment, 2 Tensiometer cups,<br />

saturation bowl<br />

Soil lab equipment<br />

Item<br />

Art.no.<br />

Hyprop kits<br />

Basic starter kit Hyprop-S<br />

Starter kit with<br />

scale<br />

Hyprop-SW<br />

Extension kit Hyprop-E<br />

Accessories<br />

Sampling ring, 250ml SZ250<br />

Laboratory scale with RS232<br />

interface<br />

Hyprop-W<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

29


Service<br />

<strong>UMS</strong> service principles<br />

For the set-up of measuring stations<br />

we offer the full service from first<br />

conception to design, supply,<br />

installation, training, initial start up<br />

and maintenance.<br />

To ensure a reliable operation<br />

in the long run, a complete<br />

service catalogue according to your<br />

demands is planned in advance.<br />

This will not only include the ideal<br />

specifications for instrumentation<br />

and measuring equipment, but will<br />

also consider the later operation,<br />

maintenance, data handling and data<br />

evaluation.<br />

„It is our aim to give you the best possible support in your tasks“<br />

This principle is the basis for our complete range of activity, sorted into six service categories:<br />

1. Workshops and product training<br />

It is our aim that you get the<br />

appropriate instrumentation<br />

for your tasks, that you can work<br />

perfectly with your system, and that<br />

you are satisfied with it.<br />

Therefore, we offer workshops as<br />

well as individual training for our<br />

products. We will show you how to<br />

handle, maintain or calibrate your<br />

instruments and how to validate and<br />

interpret your data.<br />

Training: T4 Tensiometer handling<br />

<strong>UMS</strong> workshop about pore water sampling<br />

In our workshops current topics<br />

and solutions are presented and<br />

discussed. Benefit from this<br />

impartial forum, exchange<br />

experiences with colleagues and<br />

get to know new methods and<br />

techniques.<br />

We would be please to welcome you.<br />

Current dates on www.ums-muc.de<br />

2. Your inquires - our consultancy<br />

We are pleased to answer your<br />

inquiries - whether it is about a lowcost<br />

sensor or a high-end system.<br />

In accordance with your target we<br />

will select the proper instrumentation<br />

and make you a detailed offer,<br />

including the description of the sensor<br />

specifications and components.<br />

3. Ordering and delivery<br />

Each order we may carry out for you<br />

will be managed by your personal<br />

contact who will take care of a correct<br />

and fast delivery - a part of our quality<br />

assurance system.<br />

30 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


4. Installation & maintenance<br />

„The complete is more than just the<br />

sum of parts“ - an important guideline<br />

when sensors, loggers and sampling<br />

instruments are synchronised in one<br />

system which must operate reliably<br />

over many years.<br />

... if necessary even in wintertime,<br />

Service<br />

Our engineers are available for the<br />

planning, pre-assembling and testing<br />

of your instruments, as well as for<br />

field work installation and long-term<br />

maintenance wherever feasable.<br />

Installation of a measuring site,<br />

... or in breezier heigths!<br />

5. Warranty & repair<br />

A 12 month warranty is valid for all our products. For the ceramic cups of T4 and<br />

T8 Tensiometers we offer a lifetime warranty: if a cup breaks, we will send you<br />

a replacement free of charge.<br />

Any repair will be handled as quick as possible to keep the drop out of your<br />

system as short as possible! Please remind that continous maintenance can<br />

help to reduce failures.<br />

6. Maintenance & calibration<br />

Systems must operate continuously and reliable, but any instrumentation can<br />

only work as good as it is maintained. Many failures can be avoided by correct<br />

maintenance. In dependence of the required accuracy sensors and loggers<br />

need to be checked and calibrated regularly.<br />

Please contact us or your local dealer for our calibration service.<br />

Closing words<br />

We take responsibility for our mistakes - and want to learn from them. Therefore, we would be pleased to receive your<br />

comments and suggestions.<br />

Are you satisfied with our service and products? Please tell your colleagues who might appreciate your<br />

recommendation.<br />

We wish you good success.<br />

Your <strong>UMS</strong> team<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

31


Units & Standards<br />

Guide to water potential units<br />

pF hPa kPa bar psi rF<br />

Wet 1 10 1 0.01 0.1450 0.999993<br />

2 100 10 0.1 1.4504 0.999926<br />

FK field capacity 2.53 339 33.9 0.33 4.9145 0.999756<br />

Standard tensiometer range 2.93 851 85.1 0.85 12.345<br />

3 1 000 100 1 14.504 0.999261<br />

4 10 000 1 000 10 145.04 0.992638<br />

Please PWP permanent do not hesitate wilting point to contact us for further 4.18 information 15 136 and assistance 1 513 or for a 15quotation:<br />

219.52 0.988977<br />

5 100 000 10 000 1 00 1 450.4 0.928772<br />

Air-dry, depending on humidity 6 1 000 000 100 000 1 000 14 504 0.477632<br />

Oven-dry 7 10 000 000 1 000 000 10 000 145 038 0.000618<br />

pF - is the base 10 logarithm of the water potential in cm<br />

hPa - soil water pressure in [hPa] related to atmospheric pressure<br />

kPa - soil water pressure in [kPa] related to atmospheric pressure<br />

bar - soil water pressure in [bar] related to atmospheric pressure<br />

psi - soil water pressure in [psi] related to atmospheric pressure<br />

rF - is the relative humidity computed assuming an air temperature of 293 K<br />

Signal definition of our Tensiometers<br />

Tensiometers measure soil water tensions (suction forces), which are negative pressures. Therefore, tension readings<br />

of our Tensiometers have a negative sign. In reverse, if soils are saturated and the Tensiometer is below a water level,<br />

the readings have a positive sign (pressure of water).<br />

This changed definition has become effective on 1st January 2006.<br />

IP protection classes<br />

IPXY<br />

X - 1st digit- protection against solid objects<br />

Y - 2nd digit - protection against liquids<br />

1st digit Degree of protection 2nd digit Degree of protection<br />

0 No protection 0 No protection<br />

1 Protected against solid objects over 50 mm 1 Protected against vertically falling drops of water.<br />

2 Protected against solid objects over 12 mm 2 Protected against direct sprays of water up to 15 °<br />

from the vertical.<br />

3 Protected against solid objects over 2,5 mm 3 Protected against sprays to 60° from the vertical .<br />

4 Protected against solid objects over 1 mm 4 Protected against water sprayed from all directions<br />

– limited ingress permitted.<br />

5 Protected against dust – limited ingress permitted<br />

(no harmfull deposit.)<br />

5 Protected agains low pressure jets of water from all<br />

directions - limited ingress permitted.<br />

6 Totally protected against dust. 6 Protected against strong jets of water e g for use on<br />

shipdecks - limited ingress permitted.<br />

7 Protected against the affects of immersion between<br />

15 cm and 1 m.<br />

8 Protected against long periods of immersion under<br />

pressure.<br />

Protection classification according to DIN EN 60529 (VDE 0470)<br />

Example: IP65<br />

IP6x - Totally protected against dust.<br />

IPx5 - Protected agains low pressure jets of water from all directions - limited ingress permitted.<br />

32 <strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de


Abstract of our reference list - system technology product line:<br />

Germany<br />

GSF - National Research Center for<br />

Environment and Health:<br />

Institute for plant pathologie<br />

1 irrigation site<br />

Institute for soil ecology:<br />

4 soil hydrological measuring stations<br />

1 extensive lysimeter facility<br />

5 soil heating experimantal sites<br />

Institute for radiation protection:<br />

3 mobile weather stations with<br />

GSM global data transmission<br />

TUM Technical University Munich:<br />

Chair of Soil Science:<br />

6 soil hydrological measuring stations<br />

6 suction cup installations<br />

Chair of Vegetable Science:<br />

1 soil hydrological measuring station<br />

Chair of Physics:<br />

1 irrigation site<br />

Chair of Vegetation Ecology:<br />

4 automatic water level systems<br />

LMU Ludwig-Maximilians-<br />

University, Munich:<br />

Chair of Soil Science:<br />

4 soil hydrological measuring stations<br />

13 weather stations<br />

Chair of Forest Yield Science:<br />

3 tree-growth measuring sites<br />

LWF - Bavarian Forest Institute:<br />

8 soil hydrological measuring<br />

stations and soil laboratory system<br />

Bavarian Institute for Water<br />

Management:<br />

Soil hydrological measuring station<br />

Bavarian State Research Center for<br />

Agriculture:<br />

1 lysimeter installation<br />

FNL - Agency for Ecological Field<br />

Studies, Munich:<br />

Chair of Soil Science:<br />

13 soil hydrological measuring stations<br />

FAM - Research Association Agro-Ecosystems,<br />

Munich:<br />

18 weather stations<br />

LfU - Bavarian Environmental Protection<br />

Agency:<br />

1 soil hydrological analytical stations<br />

2 laboratory systems pH-research<br />

LGA Bavarian Public Corporation<br />

Service Company, Nuremberg:<br />

1 soil hydrological measuring station<br />

University of Goettingen:<br />

12 weather stations<br />

3 weather stations (Bolivia, Geogr.Inst.)<br />

1 Lysimeter station relaunched<br />

BEAK Consultants, Freiburg:<br />

1 soil hydrological measuring station<br />

LAF Forest Institute, State of Saxony:<br />

4 soil hydrological measuring stations<br />

University of Hohenheim:<br />

Suction cup installation<br />

UMEG GmbH, Karlsruhe:<br />

Soil hydrological measuring station<br />

BASF:<br />

Limburger Hof<br />

5 micro cosmic systems<br />

Agricultural Center<br />

1 soil hydrological measuring station<br />

1 rain measuring systems<br />

1 soil hydrolgic station<br />

Bayer AG, Leverkusen:<br />

Suction cup installation<br />

ECT Ökotoxikologie GmbH,<br />

Flörsheim/Frankfurt:<br />

5 micro cosmic systems<br />

University Gesamthochschule Kassel:<br />

3 suction cup installations<br />

Research Center Jülich GmbH:<br />

6 suction cup installations, tensiometer<br />

University of Bayreuth:<br />

1 soil hydrological measuring station<br />

Ruhr-University Bochum:<br />

2 soil hydrological measuring stations<br />

4 automatic water level stations<br />

Bavarian Environmental Protection<br />

Agency, department for substances and<br />

chemicals evaluation:<br />

1 lysimeter station with 8 monoliths<br />

1 lysimeter station with 20 monoliths<br />

40 lysimeters<br />

International<br />

Austrian State of Tyrol:<br />

1 soil hydrological measuring station<br />

University of Natural Resources and<br />

Applied Life Sciences, Vienna:<br />

1 weather station<br />

Joanneum Research Center, Graz:<br />

1 lysimeter station<br />

3 soil hydrological measuring stations<br />

4 suction cup installations<br />

1 lysimeter installation<br />

2 weather stations<br />

1 automatic water level station<br />

2 monitoring stations (nitrate, pH, O2)<br />

Austrian Research Center Seibersdorf:<br />

1 lysimeter installation<br />

Austrian State of Carinthia:<br />

1 lysimeter installation<br />

State of Lower Austria, St. Pölten:<br />

2 soil hydrological measuring stations<br />

Geoconsult ZT GmbH, Salzburg:<br />

1 suction cup installation<br />

Austrian State of Styria, Graz:<br />

1 mountain Lysimeter station<br />

1 soil hydrological measuring station<br />

University Napoli, Italy:<br />

1 lysimeter station with 8 monoliths<br />

Ufficio Agrario di Pordenone, Italy:<br />

1 lysimeter installation<br />

BRGM France:<br />

1 soil hydrological measuring station<br />

University of Bangor, Wales:<br />

5 micro cosmic systems<br />

University of Coimbra, Portugal:<br />

5 micro cosmic systems<br />

United States Department of<br />

Agriculture, USA:<br />

1 soil hydrological measuring station<br />

Universidad de Estudios de Postgrado,<br />

Ecuador:<br />

1 soil chemical measuring station<br />

1 soil hydrological measuring station<br />

Fundacao Coppetec, Rio de Janeiro,<br />

Brasil:<br />

Soil hydrological measuring stations<br />

University of Ulaanbaatar, Mongolia:<br />

1 soil hydrological measuring station<br />

1 suction cup installations<br />

Realized systems<br />

<strong>UMS</strong> GmbH • Gmunder Str. 37 • 81379 Muenchen • Germany • Tel.: +49 (0) 89-12 66 52-0 • Fax: +49 (0) 89-12 66 52-20 • www.ums-muc.de<br />

33


Contact<br />

Georg von Unold<br />

< Managing Director<br />

< Lysimeter systems<br />

<strong>UMS</strong> GmbH<br />

Gmunder Str. 37<br />

81379 Muenchen / Germany<br />

Tel. +49 (0) 89 / 12 66 52 - 0<br />

Fax +49 (0) 89 / 12 66 52 - 20<br />

eMail: ums@ums-muc.de<br />

Internet: www.ums-muc.de<br />

Please do not hesitate to contact us for further information and assistance or for a quotation:<br />

Axel Rescher<br />

< Monitoring Systems<br />

< Order Processing<br />

Ext. - 15<br />

gvu@ums-muc.de<br />

Ext. - 13<br />

ar@ums-muc.de<br />

Martin Naleppa<br />

< International Sales<br />

< Dendrometers<br />

Thomas Keller<br />

< International Sales<br />

< Systems<br />

< Maintenance & Service<br />

Ext. - 14<br />

mn@ums-muc.de<br />

Ext. - 19<br />

tk@ums-muc.de<br />

Thomas Pertassek<br />

< BaPS<br />

< tensioVIEW<br />

< <strong>UMS</strong>-Soil-Lab-Services<br />

< R&D<br />

Ext. - 17<br />

tp@ums-muc.de<br />

Andreas Steins<br />

< R&D<br />

< Electronics<br />

< Systems, Data aquisition<br />

Ext. - 18<br />

as@ums-muc.de<br />

Sonja Gassner<br />

< Accounting<br />

Markus Berkmüller<br />

< Systems Support<br />

< R&D<br />

Ext. - 10<br />

sg@ums-muc.de<br />

Ext. - 23<br />

mb@ums-muc.de<br />

Jessica Oschmannr<br />

< Export order processing<br />

Stefan Engelhardt<br />

< Lysimeter Solutions<br />

< <strong>UMS</strong>-Soil-Lab-Services<br />

Ext. - 10<br />

jo@ums-muc.de<br />

Terms & conditions<br />

< Effective terms: ‘The General Conditions For The Supply Of<br />

<strong>Product</strong>s And Services Of The Electrical And Electronics Industry’<br />

< Warranty: One year on <strong>UMS</strong> parts and labour<br />

< Returns & repairs: Please contact us for instructions before<br />

shipping<br />

< Price list, delivery time and payment terms on request<br />

Ext. - 12<br />

se@ums-muc.de<br />

Specifications are subject to error or<br />

change without notice.<br />

<strong>UMS</strong> acknowledges all manufacturers<br />

trademarks referred to in this catalogue.<br />

© <strong>UMS</strong> GmbH 2010<br />

34 <strong>UMS</strong> GmbH · Gmunder Str. 37 · 81379 Muenchen · Germany · Tel.: +49 (0) 89-12 66 52-0 · Fax: +49 (0) 89-12 66 52-20 · www.ums-muc.de


Our worldwide partners give you the best support<br />

ASIA<br />

China (P. R.) and Hong Kong<br />

AOZUO Ecology Instrumentation Ltd<br />

25G, HengXing Building<br />

89 Zhong Guan Cun Eastern Road<br />

Haidian District<br />

Beijing,100080<br />

China<br />

Tel +86-10-82675321<br />

Fax +86-10-82623152<br />

sales@aozuo.com.cn<br />

www.aozuo.com.cn<br />

Contact: Ms. Jane Li<br />

AUSTRALIA<br />

MEA Pty. Ltd.<br />

Measurement Engineering Australia<br />

41 Vine Street<br />

Magill<br />

South Australia 5072<br />

Tel.: (61 8) 8332 9044<br />

Fax: (61 8) 8332 9577<br />

sales@mea.com.au<br />

www.mea.com.au<br />

Contact: Ms. Sonja van Wegen<br />

Korea<br />

C&H INC<br />

Rm 1505, Hwanghwa Bldg.<br />

Yeok Sam-Dong, Kang Nam-Ku<br />

Soul<br />

Korea<br />

Tel.: +82 2 501 3869<br />

Fax.: +82 2 556 0480<br />

pedol@freechal.com<br />

www.candh.net<br />

Contact: Mr. J.K. Park<br />

EUROPE<br />

Austria<br />

<strong>UMS</strong> GmbH<br />

Gmunder Str. 37<br />

81379 Muenchen<br />

Germany<br />

Tel.: +49-89 / 12 66 52 - 0<br />

Fax: +49-89 / 12 66 52 - 20<br />

gvu@ums-muc.de<br />

www.ums-muc.de<br />

Contact: Mr. Georg v. Unold<br />

Czech Republic and Slovakia<br />

EKOTECHNIKA spol. s r.o.<br />

Mokropeská 1832<br />

252 28 Èernošice<br />

Czech Republic<br />

Tel.: +420 2 5164 0511<br />

Fax:+420 2 5164 0512<br />

ekotechnika@ekotechnika.cz<br />

www.ekotechnika.cz<br />

Contact: Mr. Martin Jurkovic<br />

Hungary<br />

Envirotools Bt.<br />

2624 Szokolya<br />

Petőfi u. 8<br />

Hungary<br />

Tel.: +36-1-275-9424<br />

Fax: +36-30-346-1173<br />

envirotools@mailbox.hu<br />

www.envirotools.hu<br />

Contact: Mr. Sandor Haden<br />

France<br />

SOLS MESURES<br />

17 rue Jean Monnet - ZA des c’tes<br />

78990 ELANCOURT<br />

France<br />

Tel.: +33 (1) 30 - 50 34 50<br />

Fax: +33 (1) 30 - 50 34 49<br />

info@sols-mesures.com<br />

www.sols-mesures.com<br />

Contact: Ms. Jessica Soulice<br />

Spain<br />

LAB-FERRER / Centre d‘Assessoria<br />

Dr Ferrer SL, c/Ferran el catòlic, 3<br />

25200 CERVERA (LLEIDA)<br />

TEL/FAX: +34-973-53 21 10<br />

francesc@lab-ferrer.com<br />

WWW.LAB-FERRER.COM<br />

Contact: Mr. Francesc Ferrer Alegre<br />

Netherlands<br />

Eijkelkamp Agrisearch Equipment<br />

Nijverheidsstraat 30<br />

P.O. Box 4<br />

6987 EM Giesbeek<br />

Netherlands<br />

Tel.: +31 313 880200<br />

Fax: +31 313 632167<br />

eijkelkamp@eijkelkamp.com<br />

www.eijkelkamp.com<br />

Poland<br />

Geomor-Technik Sp. z o.o.<br />

ul. Bialowieska 2<br />

71-010 Szczecin<br />

Poland<br />

Tel./Fax.: +48-91 482 60 87<br />

Tel.: + 48-91 482 00 90<br />

geomor@geomor.com.pl<br />

www.geomor.com.pl<br />

Contact: Mr. Daniel Hrynkiewicz<br />

Sweden<br />

TORAGON AB<br />

Umestan Företagspark, hus 3<br />

903 47 UMEÅ<br />

Sweden<br />

Tel.: +46 90 100 260<br />

Fax: +46 90 100 261<br />

http://toragon.se<br />

info@toragon.se<br />

Contact: Mr. Torsten Karlsson<br />

United Kingdom<br />

DELTA-T Devices Ltd<br />

128 Low Road<br />

Burwell, Cambridge, CB5 0EJ<br />

United Kingdom<br />

Tel.: +44 1638 742922<br />

Fax: +44 1638 743155<br />

sales@delta-t.co.uk<br />

www.delta-t.co.uk<br />

Contact: Mr. Dick Jenkins<br />

USA<br />

AMERICA<br />

Decagon Devices, Inc.<br />

950 NE Nelson Court<br />

Pullman, WA 99163<br />

Tel: 1-800-755-2751 (US)<br />

509-332-2756 (International)<br />

Fax: 509-332-5158:<br />

sales@decagon.com<br />

www.decagon.com<br />

Contact: Mr. Nick Mower<br />

Canada<br />

Hoskin Scientific LTD<br />

4210 Morris Drive<br />

Burlington, Ontario L7L 5L6<br />

Tel.: 9 05 3 33 - 55 10<br />

Fax: 9 05 3 33 - 49 76<br />

www.hoskin.ca<br />

Burlington office: salesb@Hoskin.ca<br />

Vancouver office: salesv@Hoskin.ca<br />

Montreal office: salesm@Hoskin.ca<br />

Brazil<br />

Sócio Gerente<br />

Rua Paschoal Carlos Magno, 57<br />

20240-290 - Rio de Janeiro - RJ<br />

Tel: +55 (21) 2224-1997<br />

Skype: transatlantic-consulting<br />

tensio@transatlantic.com.br<br />

http://www.tensio.com.br<br />

Contact: Mr. Hans Rauschmayer<br />

GERMANY<br />

<strong>UMS</strong> GmbH<br />

Gmunder Str. 37<br />

81379 Muenchen<br />

Tel.: +49 89 / 12 66 52 - 0<br />

Fax: +49 89 / 12 66 52 - 20<br />

ar@ums-muc.de<br />

www.ums-muc.de<br />

Contact: Mr. Axel Rescher<br />

NOT LISTED COUNTRIES<br />

<strong>UMS</strong> GmbH<br />

Gmunder Str. 37<br />

81379 Muenchen<br />

Tel.: +49 89 / 12 66 52 - 0<br />

Fax: +49 89 / 12 66 52 - 20<br />

mn@ums-muc.de<br />

www.ums-muc.de<br />

Contact: Mr. Martin Naleppa<br />

Distributors<br />

<strong>UMS</strong> GmbH · Gmunder Str. 37 · 81379 Muenchen · Germany · Tel.: +49 (0) 89-12 66 52-0 · Fax: +49 (0) 89-12 66 52-20 · www.ums-muc.de<br />

35


Distributed by:<br />

<strong>UMS</strong> GmbH<br />

Gmunder Str. 37<br />

81379 Muenchen<br />

Germany<br />

Tel.: +49 (0) 89 / 12 66 52 - 0<br />

Fax.: +49 (0) 89 / 12 66 52 - 20<br />

www.ums-muc.de<br />

info@ums-muc.de