Frame Assignment

tohyu.trading.com

Frame Assignment

SUPACT Insulation System

Testing

A unique mica/glass insulation system, vacuum pressure impregnated with 100% solids epoxy Resin, and high-build epoxy varnish

for finish treatment ensures the strongest resistance to chemical attack or contamination.

Hyosung SUPACT Insulation system has demonstrated its durability under the most arduous industrial and climatic conditions in

high voltage drives.

Routine Test Scope

Our factories use state of art test facilities and equipments to verify design data in accordance with design standards, including noise

testing to IEC 34-9, NEMA MG-3, and IEEE standard 85. Routine test reports are furnished without charge, and include the

following standard tests:

VPI

Process

Drying

160˚C

4 hour

Vacuum

0.09 mbar

3 hour

Impregnation

0.09 mbar

0.5 hour

Pressure

5 kg/

5.5 hour

Drying

175 ˚C

8 hour

Inspection of Material Construction

Measurement of Vibration

Measurement of Winding Resistance

Check of Rotation

Measurement of Insulation Resistance

No Load Test

High Voltage Test

Locked Rotor Test

Temperature Test

Measurement of Locked Rotor Current

Measurement of Performance

Impregnation of core and coil assemblies VPI facility Control System for VP

Over Speed Test

Shaft Current Test

Momentary Excess Torque Test

Average Life

Allowable temperature by insulation class

CLASS

A

E

B

F

H

Temp.Rise

105˚C

120˚C

130˚C

155˚C

180˚C

LARGE MOTORS 10/11

More magazines by this user