01.11.2014 Views

Highline 270 EC Waterside Fan Coil Unit - Keane Environmental

Highline 270 EC Waterside Fan Coil Unit - Keane Environmental

Highline 270 EC Waterside Fan Coil Unit - Keane Environmental

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Features:<br />

Electronically<br />

Commutated (<strong>EC</strong>)<br />

fan motor<br />

Specific <strong>Fan</strong> Power<br />

of 0.16 to 0.34 at<br />

NR35<br />

Insignificant<br />

fan heat gain<br />

Designed to operate<br />

below NR35 at<br />

External Static<br />

Pressures of up to<br />

50Pa<br />

Variable speed<br />

<strong>Fan</strong> adjustment<br />

Ceiling and<br />

Underfloor<br />

installation<br />

Low surface<br />

temperature on<br />

electric element<br />

Low Maintenance<br />

<strong>Highline</strong> <strong>270</strong> <strong>EC</strong> <strong>Waterside</strong> <strong>Fan</strong> <strong>Coil</strong> <strong>Unit</strong>


<strong>Highline</strong> <strong>270</strong><strong>EC</strong> <strong>Waterside</strong> <strong>Fan</strong> <strong>Coil</strong> <strong>Unit</strong><br />

<strong>Fan</strong> <strong>Coil</strong> <strong>Unit</strong><br />

The most popular waterside control<br />

fan coil unit in the UK for the past<br />

15 years, now available with <strong>EC</strong><br />

fans having low Specific <strong>Fan</strong><br />

Powers. Initially designed to be<br />

fitted into a ceiling void, the<br />

flexibility also allows the unit to be<br />

installed underfloor. Furthermore an<br />

alternative to the standard design is<br />

the <strong>Highline</strong> 260d, which<br />

incorporates a detachable discharge<br />

plenum and enables a more flexible<br />

discharge arrangement.<br />

Chassis<br />

<strong>Unit</strong>s are manufactured from 1.0 -<br />

1.6mm hot dipped galvanised steel and<br />

are constructed without the use of self<br />

tapping screws. All thermal and<br />

acoustic lining is CFC and HCFC<br />

free and class '0' fire rated. All<br />

bearings and moving surfaces will<br />

operate without requiring further<br />

lubrication. All electrical components<br />

and electrical wiring comply with the<br />

current edition of the I.E.E.<br />

regulations. Each unit is factory<br />

tested to ensure that it will continue<br />

to meet its specified performance<br />

with the minimum of maintenance,<br />

throughout its life.<br />

<strong>Fan</strong>s<br />

The fans are of the double inlet, double<br />

width centrifugal type. The scrolls are<br />

manufactured from galvanized mild<br />

steel, complete with forward curved<br />

aluminum or galvanized steel bladed<br />

impellers. All fan and motor<br />

assemblies are statically and<br />

dynamically balanced to prevent the<br />

transmission of vibration to the fan<br />

coil unit casing. Each fan and motor<br />

assembly has thermal<br />

overload protection fitted, via<br />

imbedded thermistors or the<br />

commutation electronics. The motors<br />

comply to BS 5000-11 and BS EN<br />

60034. The motor frame is totally<br />

enclosed and fitted with maintenance<br />

free sealed for life ball bearings.<br />

Motors are insulated to BS 2757<br />

class B (minimum) and tested to BS<br />

EN 61000-3-2 for Harmonic<br />

Distortion and BS EN 61000-3-3<br />

for Flicker.<br />

Heat Exchangers<br />

<strong>Coil</strong>s are manufactured from 0.35 mm<br />

thick solid drawn copper tubes,<br />

mechanically expanded into accurately<br />

pre-formed collars in rippled aluminum<br />

fins. The coils are arranged for<br />

single or multi- circuit operation<br />

via headers. Each coil is fitted with<br />

a manual air vent and drain point.<br />

All coils are factory tested to a<br />

minimum of 35 bar and are suitable for<br />

operating pressures of up to 12 bar<br />

static head. <strong>Coil</strong>s are fitted with 15<br />

mm o/d plain copper tails.<br />

Condensate Drip Tray<br />

The condensate drip tray is manufactured<br />

from hot dipped galvanized steel,<br />

welded at each corner. The tray is then<br />

degreased before anti-condensation<br />

insulation is applied to all internal and<br />

external surfaces. The tray is fitted<br />

with 15 mm o/ d plain brass connection<br />

(22 mm o/d optional). The tray has a<br />

built in gradient to ensure correct<br />

drainage of condensate.<br />

Temperature Controls<br />

Temperature control shall be by<br />

modulation of the control valves<br />

allowing either chilled or heated<br />

water to flow through the<br />

appropriate coil.<br />

Air Filter Options<br />

-Mesh Filter - The filter is<br />

permanent and is manufactured<br />

from a fine woven mesh of<br />

galvanized steel wire, welded to a<br />

rigid galvanized steel frame. It can be<br />

vacuum cleaned in-situ, or<br />

periodically removed for washing<br />

when necessary.<br />

-Media type filter - Filters are<br />

EU3 to Eurovent 4/5 and<br />

manufactured from a synthetic media<br />

secured to a wire metal frame.<br />

Discharge Plenum<br />

The discharge and inlet plenums are<br />

attenuated and thermally lined with a<br />

CFC and HCFC free class '0' fire<br />

retardant non-migratory foam,<br />

which is both vermin and rot proof.<br />

The density of the foam is 11<br />

kg/m3 thereby helping to reduce the<br />

total weight of the fan coil unit.<br />

Electric Heat Element (if required)<br />

The element is manufactured from<br />

stainless steel sheath with spiral<br />

wound stainless steel fins to minimize<br />

surface temperature. It is located<br />

upstream of the fan(s) to evenly<br />

distribute the heat to the final<br />

discharge spigots. Each unit shall<br />

incorporate a manual reset high<br />

temperature cut-out and a Pressure<br />

Differential Switch or Current<br />

Switch, wired to prevent operation<br />

in the event of a fan failure.


1. ACOUSTIC LINED UNIT AS STANDARD.<br />

UNIT<br />

06<br />

09<br />

A<br />

691<br />

911<br />

B<br />

645<br />

865<br />

12 1066 1020<br />

13 1244 1198<br />

15 1491 1445<br />

C<br />

608<br />

828<br />

983<br />

1161<br />

1408<br />

197 SPIGOTS TOTAL<br />

SPIGOT PITCH: D No.OFF<br />

250 4<br />

260-260<br />

300-300<br />

350-350<br />

325-325-325<br />

5<br />

5<br />

5<br />

6<br />

247 SPIGOTS TOTAL<br />

SPIGOT PITCH: D No.OFF<br />

300 4<br />

400<br />

453<br />

350-350<br />

455-455<br />

18 1876 1830 1793 350-350-350-350 7 350-350-350-350 7<br />

4<br />

4<br />

5<br />

5<br />

167.0<br />

MAX.<br />

23.0<br />

87.0<br />

A REAR PANEL<br />

B FIXING CENTRES<br />

135.0<br />

2. LEFT HAND UNIT AS DRAWN,<br />

RIGHT HAND OPPOSITE HAND,<br />

(HEATING AND COOLING VALVES REVERSED<br />

SEE SCRAP VIEW BELOW).<br />

3. BY LOOSENING ONE THUMBSCREW THE FILTER<br />

CAN BE REMOVED STRAIGHT OFF THE END OF<br />

THE UNIT, ALTERNATIVELY, THE FILTER CAN<br />

DROP DOWN AND SLIDE OUT.<br />

4. GENERAL TOLERANCE ON OVERALL<br />

DIMENSIONS +/- 4mm.<br />

DISCHARGE OPTIONS.<br />

C ACCESS PANEL<br />

ITEM<br />

DESCRIPTION<br />

1 DISCHARGE SPIGOTS 197 TYP. OR 247 TYP.<br />

2 DISCHARGE PLENUM.<br />

3 UNIT REAR PANEL.<br />

4 COIL VENTS.<br />

5 THUMBSCREWS FOR FILTER REMOVAL.<br />

6 COOLING CONN<strong>EC</strong>TIONS SIZE 06,09,12,13,15: 15mm.<br />

COOLING CONN<strong>EC</strong>TIONS SIZE 18 ONLY: 22mm.<br />

7 COIL DRAINS.<br />

8 HEATING CONN<strong>EC</strong>TIONS 15mm.<br />

9 CONTROL BOX C/W FAN ON/OFF SPEED AND<br />

TRIM CONTROLS, (NOT REQUIRED ON <strong>EC</strong> UNITS)<br />

10<br />

11<br />

12<br />

13<br />

14<br />

15<br />

CONDENSATE DRIP TRAY.<br />

CONDENSATE DRAIN 22mm.<br />

TAB FOR FILTER REMOVAL (SEE NOTE 3).<br />

FILTER (SEE NOTE 3).<br />

UNIT FIXING HOLE 19.0 TYP.<br />

FAN ACCESS COVER.<br />

700.0<br />

66.0<br />

1<br />

2<br />

3<br />

4<br />

DIR<strong>EC</strong>TION<br />

OF DISCHARGE.<br />

733.0<br />

H<br />

8<br />

9<br />

10<br />

11<br />

278.0<br />

343.0<br />

= D SPIGOT PITCH D SPIGOT PITCH =<br />

319.0<br />

510.0<br />

FIXING CENTRES<br />

287.0<br />

357.0<br />

ACCESS PANEL<br />

<strong>270</strong>.0<br />

135.0<br />

139.0<br />

50.0<br />

TYP.<br />

860.0<br />

5<br />

157.0 40.0<br />

RETURN<br />

FLOW<br />

263.0<br />

7<br />

165.0<br />

DIR<strong>EC</strong>TION<br />

OF FILTER<br />

50.0<br />

REMOVAL 1.<br />

COIL TAILS<br />

6 12 13 14 15<br />

C<br />

VIEW ON UNDERSIDE OF LEFT HAND UNIT.<br />

DIR<strong>EC</strong>TION<br />

OF FILTER<br />

REMOVAL 2,<br />

(DROP DOWN).<br />

22.0<br />

OPTIONS:<br />

1. INLET SPIGOT WITH SLIDE DOWN FILTER (NOT SHOWN).<br />

2. CONDENSATE PUMP (NOT SHOWN).<br />

3. EL<strong>EC</strong>TRIC HEATING ELEMENTS (NOT SHOWN).<br />

4. FRESH AIR SPIGOT.<br />

5. ANTI-VIBRATION MOUNTS.


Options<br />

Underfloor installation available<br />

Electric Heat(Stainless Steel sheathed element) with Thermal Cut-out<br />

Differential Pressure Switch for heating element protection(Standard)<br />

Current Switch for heating element protection(Optional)<br />

Power Correction Module<br />

Speed Controller! Speed Limiter<br />

24v Transformer<br />

Condensate pumps<br />

DIFFUSION <strong>Unit</strong> Coding System<br />

UNIT MODEL FAN TYPE CONTROL APPLICATION OPTIONS UNIT SIZE Chassis<br />

HIGHLINE <strong>270</strong> <strong>EC</strong>-Electronically commutated W - <strong>Waterside</strong> H - Horizontal E - EL<strong>EC</strong>TRIC 06 CH<br />

UF - Underfloor CO - COOLING ONLY 09<br />

12<br />

13<br />

15<br />

18<br />

e.g.<br />

HIGHLINE <strong>270</strong> <strong>EC</strong>-W-H-09-CH<br />

HIGH LINE <strong>270</strong>, with <strong>EC</strong> fans, <strong>Waterside</strong> Horizontal, 4 pipe, size 9, chassis<br />

HIGHLINE <strong>270</strong> <strong>EC</strong>-W-UF-CO-09-CH<br />

HIGH LINE <strong>270</strong>, with <strong>EC</strong> fans, <strong>Waterside</strong> Underfloor, Cooling Only, size 9, chassis<br />

HIGHLINE <strong>270</strong> <strong>EC</strong>-W-H-E-09-CH<br />

HIGH LINE <strong>270</strong>, with <strong>EC</strong> fans, <strong>Waterside</strong> Horizontal, 2 pipe, Electric Heat, size 9, chassis<br />

Established in 1960,<br />

Diffusion has over 50 years<br />

experience in producing<br />

environmental solutions<br />

via the manufacture of heating,<br />

air conditioning and<br />

ventilating products.<br />

Diffusion <strong>Environmental</strong> Systems<br />

47 Central Avenue, West Molesey, Surrey KT8 2QZ<br />

Tel: (+44) 020 8783 0033 Fax: (+44) 020 8783 0140<br />

Email: diffusion@etenv.co.uk www.diffusion-group.co.uk<br />

Diffusion <strong>Environmental</strong> Systems have a policy of continuous<br />

development. We therefore reserve the right to alter information<br />

contained in this leaflet, without prior notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!