BODAS Sensors<br />
As a component of the BODAS system,<br />
the sensors supply the controller<br />
with important machine and<br />
environment information. Sensors<br />
for mobile equipment must be<br />
able to withstand extreme ambient<br />
loads, particularly if installed near<br />
the hydraulic power packs and engines.<br />
The sensors for different measured<br />
variables are based on robust, failsafe,<br />
usually contactless measurement<br />
principles.<br />
The sensor elements are reliably<br />
integrated in suitable cases where<br />
they are protected against vibrations,<br />
impacts and harmful fluids,<br />
and are equipped with cables or<br />
plug connectors suitable for mobile<br />
use.<br />
Features<br />
- Matched to BODAS controllers<br />
and <strong>Rexroth</strong> mobile hydraulics<br />
- High temperature range<br />
- Short-circuit and reverse-connect<br />
protection (in some cases)<br />
- High electromagnetic compatibility<br />
(EMC)<br />
- High IP degree of protection for<br />
mobile use<br />
Detailed information:<br />
DSM RE 95132<br />
HDD RE 95135<br />
ID RE 95130<br />
PR2 RE 95138<br />
WS1 RE 95140<br />
TSF RE 95180<br />
TSA RE 95181<br />
TS RE 95145<br />
VS RE 95148<br />
Technical Data of the Sensors<br />
Type Measurement Min. value Max. value Supply Application (typical)<br />
Universal, use on wheels, installation in axial piston units<br />
DSM Speed 1 Hz 5000 Hz 12 V<br />
and gear machines with direction of rotation detection and<br />
diagnostics<br />
HDD Speed 2 Hz 6000 Hz 8 ... 32 V<br />
Installation in axial piston units, with direction of rotation<br />
detection<br />
ID Speed 500 Hz 4000 Hz -<br />
Detection of engine speed, installation in axial piston units<br />
without direction of rotation detection<br />
PR2 Pressure 0...160 bar 0...600 bar 5 V Universal<br />
WS1 Angle - -45°...+45° 5 V Universal<br />
TSF Temperature -30°C 130°C - Universal for fluids<br />
TSA Temperature -40°C 130°C - Universal for air<br />
TS Temperature 87°C 92°C - Temperature switch, universal<br />
VS Contamination - - - Universal, contamination switch for hydraulic fluids<br />
99<br />