08.11.2014 Views

Dyna Helix® DC Implant - Dyna Dental

Dyna Helix® DC Implant - Dyna Dental

Dyna Helix® DC Implant - Dyna Dental

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Dyna</strong> Helix ® <strong>DC</strong> <strong>Implant</strong><br />

The <strong>Dyna</strong> Helix ® <strong>DC</strong> implant is a tripartite cylinder screw designed<br />

to give secure mechanical fixation and load distribution in all clinical<br />

situations. It is a two-stage, screw type implant that can be used in<br />

one-stage surgery if the criteria for one stage surgery are met. It allows<br />

achieving exceptional primary stability in class IV bone whereas in class<br />

I, dense cortical bone it guarantees safe and a-traumatic insertion. <strong>Dyna</strong><br />

Helix ® <strong>DC</strong> implant is based on root form Dual Core with self tapping<br />

thread. The core of the implant allows for bone condensation during<br />

insertion supporting the primary stability in all bone types and stimulates<br />

healing process. The rounded lower edge of the implant makes<br />

the positioning of implants above the nerves more secure and surgical<br />

procedures of closed sinus lift easy and a-traumatic.<br />

The thread of the implant has been designed so that outer diameter of the<br />

implant remains the same whereas provides optimal cutting action.<br />

The use of the Cortical reamer and pre tapping is necessary when, especially<br />

in the cortical bone, there exists the risk of overheating or creating<br />

too much stress in the surrounding bone. The lower part of the treads are<br />

designed more horizontally. Because of this design the axial forces are<br />

transferred more vertically to the alveolar bone.<br />

Based on the new principles to prevent bone resorption the implants are<br />

totally treated with the ART surface. The biological width principle is<br />

respected by means of the V-shape connection to the abutment coined<br />

as platform switching. Only a two tenth of a millimeter machined polished<br />

collar gives a smooth transition to the abutment. The use of several<br />

implant diameters and all-fit-all abutments gives an ideal combination<br />

of simplicity and reliability. Every implant is supplied together with the<br />

cover screw in a sterile, double peel-pouch type packaging that assures<br />

a five year shelf life.<br />

Platform<br />

switching<br />

Diameter<br />

difference<br />

realizes bone<br />

condensation<br />

Compression zone<br />

<strong>Dyna</strong> Helix ® <strong>DC</strong> implants are available in diameters 3.2, 3.6, 4.2 and 5.0 mm<br />

and lengths 8, 10, 11.5, 13 and 15 mm<br />

Rounded lower edge<br />

for preventing sinus<br />

membrane and nerve<br />

perforation<br />

Rootshape<br />

<strong>Dyna</strong> <strong>Dental</strong> Engineering BV<br />

PO Box 70<br />

4600 AB Bergen op Zoom<br />

The Netherlands<br />

T. +31(0)164-258980<br />

F. +31(0)164-258390<br />

E. dyna@dynadental.com<br />

Ask your local dealer for more information<br />

3202-10.03<br />

www.dynadental.com<br />

Special thanks to Dr. Biesaga<br />

design: van der Plas & Lemmens BNO

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!