<strong>NLS</strong> <strong>and</strong> <strong>NLT</strong>, <strong>method</strong> A, <strong>completely</strong> <strong>supported</strong> <strong>in</strong> prepared pit (weld<strong>in</strong>g)<br />

80 x 80 x 8 mm<br />

by others<br />

L<br />

1300<br />

520<br />

40 x 2 x 140 mm<br />

by others<br />

flexible conduit Ø 50 mm<br />

for cables (by others).<br />

B<br />

1<br />

To <strong>in</strong>stall the leveller properly, the net pitmeasures<br />

should be as listed below :<br />

model L W (B)<br />

<strong>NLS</strong> 20 – 17,5 2070 1770<br />

<strong>NLS</strong> 25 – 17,5 2570 1770<br />

<strong>NLS</strong> 30 – 17,5 3070 1770<br />

<strong>NLS</strong> 34 – 17,5 3470 1770<br />

<strong>NLS</strong> 20 – 20 2070 2020<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 20 2570 2020<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 20 3070 2020<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 20 3470 2020<br />

<strong>NLS</strong> 20 – 22 2070 2220<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 22 2570 2220<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 22 3070 2220<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 22 3470 2220<br />

2<br />

Edition : september 2005<br />

technical alterations <strong>and</strong> pr<strong>in</strong>t<strong>in</strong>g errors reserved


<strong>NLS</strong> <strong>and</strong> <strong>NLT</strong>, <strong>method</strong> B, suspended with recessed angle (weld<strong>in</strong>g)<br />

60 20<br />

20 x 10<br />

80 x 80 x 8<br />

40 x 2 x 140 mm<br />

by others<br />

B<br />

L<br />

1300<br />

520<br />

flexible conduit Ø 50 mm<br />

for cables (by others).<br />

<strong>in</strong>cl<strong>in</strong>e<br />

1 cm/m<br />

1<br />

To <strong>in</strong>stall the leveller properly, the net pitmeasures<br />

should be as listed below :<br />

model L W (B)<br />

<strong>NLS</strong> 20 – 17,5 2020 1820<br />

<strong>NLS</strong> 25 – 17,5 2520 1820<br />

<strong>NLS</strong> 30 – 17,5 3020 1820<br />

<strong>NLS</strong> 34 – 17,5 3420 1820<br />

<strong>NLS</strong> 20 – 20 2020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 20 2520 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 20 3020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 20 3420 2070<br />

<strong>NLS</strong> 20 – 22 2020 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 22 2520 2270<br />

10<br />

B<br />

L<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 22 3020 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 22 3420 2270<br />

2<br />

Edition : september 2005<br />

technical alterations <strong>and</strong> pr<strong>in</strong>t<strong>in</strong>g errors reserved


<strong>NLS</strong> <strong>and</strong> <strong>NLT</strong>, <strong>method</strong> C, suspended with f<strong>in</strong>ish<strong>in</strong>g of liquid concrete<br />

Prefabricated pit:<br />

Upperside edge - 100 mm below f<strong>in</strong>ished floor level<br />

for levellers type <strong>NLS</strong> <strong>and</strong> <strong>NLT</strong><br />

chassis<br />

1<br />

flexible conduit Ø 50 mm for<br />

cables (by others).<br />

1300<br />

520<br />

To <strong>in</strong>stall the leveller properly, the net pitmeasures<br />

should be as listed below :<br />

model L W (B)<br />

<strong>NLS</strong> 20 – 17,5 2020 1820<br />

<strong>NLS</strong> 25 – 17,5 2520 1820<br />

<strong>NLS</strong> 30 – 17,5 3020 1820<br />

<strong>NLS</strong> 34 – 17,5 3420 1820<br />

<strong>NLS</strong> 20 – 20 2020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 20 2520 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 20 3020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 20 3420 2070<br />

<strong>NLS</strong> 20 – 22 2020 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 22 2520 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 22 3020 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 22 3420 2270<br />

B<br />

L<br />

<strong>in</strong>cl<strong>in</strong>e<br />

1 cm/m<br />

f<strong>in</strong>ished floor<br />

60<br />

100<br />

≥ 150<br />

10<br />

Steel strips (not supplied) have to be<br />

welded to the steel p<strong>in</strong>s (by contractor)<br />

concrete<br />

2<br />

chassis<br />

f<strong>in</strong>ished floor<br />

3<br />

Edition : september 2005<br />

technical alterations <strong>and</strong> pr<strong>in</strong>t<strong>in</strong>g errors reserved


<strong>NLS</strong> <strong>and</strong> <strong>NLT</strong>, <strong>method</strong> D1, with letter-box<br />

To <strong>in</strong>stall the leveller properly, the net pitmeasures<br />

should be as listed below :<br />

model L W (B)<br />

<strong>NLS</strong> 20 – 17,5 2020 1820<br />

<strong>NLS</strong> 25 – 17,5 2520 1820<br />

<strong>NLS</strong> 30 – 17,5 3020 1820<br />

<strong>NLS</strong> 34 – 17,5 3420 1820<br />

<strong>NLS</strong> 20 – 20 2020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 20 2520 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 20 3020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 20 3420 2070<br />

<strong>NLS</strong> 20 – 22 2020 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 22 2520 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 22 3020 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 22 3420 2270<br />

Concrete floor plate<br />

elements with cut out<br />

ø60 mm for wir<strong>in</strong>g<br />

(others)<br />

60 10<br />

L<br />

<strong>in</strong>jection channel<br />

B<br />

Prefabricated concrete<br />

T-shaped elements, prepared<br />

for attachement of the rubber<br />

bumpers.<br />

1<br />

Wall:<br />

prefabricated<br />

concrete or<br />

brickwork<br />

flexible conduit Ø 50<br />

mm for cables (by<br />

others).<br />

threaded end<br />

level<br />

Leveller deck<br />

Is protected with hardboard sheet (factory fitted)<br />

to avoid damage dur<strong>in</strong>g construction process. To<br />

be removed upon completion by contractor.<br />

2<br />

Note :<br />

Floor re<strong>in</strong>forcement must be attached<br />

to the leveller at several spots.<br />

f<strong>in</strong>ished floor<br />

3<br />

Edition : september 2005<br />

technical alterations <strong>and</strong> pr<strong>in</strong>t<strong>in</strong>g errors reserved


<strong>NLS</strong> <strong>and</strong> <strong>NLT</strong>, <strong>method</strong> D2, with letter-box<br />

To <strong>in</strong>stall the leveller properly, the net pitmeasures<br />

should be as listed below :<br />

model L W (B)<br />

<strong>NLS</strong> 20 – 17,5 2020 1820<br />

<strong>NLS</strong> 25 – 17,5 2520 1820<br />

<strong>NLS</strong> 30 – 17,5 3020 1820<br />

Chassis<br />

<strong>NLS</strong> 34 – 17,5 3420 1820<br />

<strong>NLS</strong> 20 – 20 2020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 20 2520 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 20 3020 2070<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 20 3420 2070<br />

<strong>NLS</strong> 20 – 22 2020 2270<br />

1300<br />

FFL 520 - t.o.v.PEIL 520 mm<br />

60 10<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 22 2520 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 22 3020 2270<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 22 3420 2270<br />

L<br />

Prefabricated pit:<br />

Upperside harsh concrete floor<br />

= max. f<strong>in</strong>ished floor level - 200 mm.<br />

B<br />

1<br />

flexible conduit Ø 50 mm<br />

for cables (by others).<br />

Steel re<strong>in</strong>forcement for the<br />

floor (by others)<br />

level<br />

shutter<strong>in</strong>g on the front face<br />

(by others)<br />

Threaded bushes<br />

For attachement of<br />

the bumpers (by<br />

others)<br />

Note<br />

Floor re<strong>in</strong>forcement must be<br />

attached to the leveller at<br />

several po<strong>in</strong>ts.<br />

2<br />

Leveller deck<br />

Is protected with hardboard sheet (factory fitted)<br />

to avoid damage dur<strong>in</strong>g construction process. To<br />

be removed upon completion by contractor.<br />

3<br />

Edition : september 2005<br />

technical alterations <strong>and</strong> pr<strong>in</strong>t<strong>in</strong>g errors reserved


<strong>NLS</strong> <strong>and</strong> <strong>NLT</strong> "box-model", <strong>method</strong> E, without letter-box<br />

The net distance between the floor re<strong>in</strong>forcement<br />

should be as <strong>in</strong>dicated below :<br />

type leveller L W (B)<br />

<strong>NLS</strong> 20 – 17,5 2150 1930<br />

<strong>NLS</strong> 25 – 17,5 2650 1930<br />

<strong>NLS</strong> 30 – 17,5 3150 1930<br />

<strong>NLS</strong> 34 – 17,5 3550 1930<br />

<strong>NLS</strong> 20 – 20 2150 2180<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 20 2650 2180<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 20 3150 2180<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 20 3550 2180<br />

<strong>NLS</strong> 20 – 22 2150 2380<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 22 2650 2380<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 22 3150 2380<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 22 3550 2380<br />

First cast floor to support the leveller<br />

(by others)<br />

leveller<br />

FFL - 600 mm for <strong>NLS</strong> <strong>and</strong> <strong>NLT</strong> with liplength = 500 mm<br />

FFL - 800 mm for <strong>NLT</strong> with liplength = 1000 mm<br />

FFL = f<strong>in</strong>ished floor level<br />

level<br />

Leveller deck<br />

Is protected with hardboard sheet (factory fitted)<br />

to avoid damage dur<strong>in</strong>g construction process. To<br />

be removed upon completion by contractor.<br />

1<br />

Flexible conduit Ø 50 mm for<br />

cables (by others).<br />

Steel re<strong>in</strong>forcement for the<br />

floor (by others)<br />

Connection<br />

flexible conduit<br />

2<br />

Threaded bushes<br />

M16x100 for attachement<br />

of the bumpers<br />

(by others)<br />

Shutter<strong>in</strong>g on the front<br />

face (by others)<br />

Note<br />

Floor re<strong>in</strong>forcement must<br />

be attached to the leveller<br />

at several po<strong>in</strong>ts.<br />

Edition : september 2005<br />

technical alterations <strong>and</strong> pr<strong>in</strong>t<strong>in</strong>g errors reserved


<strong>NLS</strong> <strong>and</strong> <strong>NLT</strong> "box-model", <strong>method</strong> E, with letter-box<br />

The net distance between the floor re<strong>in</strong>forcement<br />

should be as <strong>in</strong>dicated below :<br />

model L W (B)<br />

<strong>NLS</strong> 20 – 17,5 2150 1930<br />

<strong>NLS</strong> 25 – 17,5 2650 1930<br />

<strong>NLS</strong> 30 – 17,5 3150 1930<br />

<strong>NLS</strong> 34 – 17,5 3550 1930<br />

<strong>NLS</strong> 20 – 20 2150 2180<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 20 2650 2180<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 20 3150 2180<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 20 3550 2180<br />

<strong>NLS</strong> 20 – 22 2150 2380<br />

<strong>NLS</strong> / <strong>NLT</strong> 25 – 22 2650 2380<br />

<strong>NLS</strong> / <strong>NLT</strong> 30 – 22 3150 2380<br />

<strong>NLS</strong> / <strong>NLT</strong> 34 – 22 3550 2380<br />

First cast floor to support the leveller<br />

(by others)<br />

<strong>in</strong>cl<strong>in</strong>e 1 cm/m<br />

level<br />

FFL - 600 mm<br />

for <strong>NLS</strong> <strong>and</strong> <strong>NLT</strong> with liplength = 500 mm<br />

FFL - 800 mm<br />

for <strong>NLT</strong> with liplength = 1000 mm<br />

FFL = f<strong>in</strong>ished floor level<br />

1<br />

F<strong>in</strong>ished Floor Level<br />

Shutter<strong>in</strong>g platform :<br />

- stable<br />

- to be removed after<br />

cast<strong>in</strong>g the floor by<br />

contractor.<br />

Leveller deck<br />

Is protected with hardboard sheet (factory fitted)<br />

to avoid damage dur<strong>in</strong>g construction process. To<br />

be removed upon completion by contractor.<br />

box-leveller<br />

a<br />

a<br />

2<br />

Flexible conduit Ø 50 mm for<br />

cables (by others).<br />

Steel re<strong>in</strong>forcement for the<br />

floor (by others)<br />

Connection<br />

flexible conduit<br />

Threaded bushes<br />

M16x100 for attachement<br />

of the bumpers<br />

(by others)<br />

3<br />

Note<br />

Floor re<strong>in</strong>forcement must<br />

be attached to the leveller<br />

at several po<strong>in</strong>ts.<br />

Shutter<strong>in</strong>g on the front<br />

face (by others)<br />

Edition : september 2005<br />

technical alterations <strong>and</strong> pr<strong>in</strong>t<strong>in</strong>g errors reserved