Catalogue 2006<br />
<strong>Cable</strong> <strong>Management</strong> <strong>Systems</strong><br />
<strong>for</strong> <strong>underfloor</strong> installation<br />
Perfect combination of design and function<br />
UFS Underfloor systems
A good address all over the world<br />
Over 50 countries, more than 100 agencies and branches, millions of satisfied customers<br />
<strong>OBO</strong> – a globally operating company. Through branches and agencies, <strong>OBO</strong> is represented not only in Germany and Europe,<br />
but in more than fifty countries all over the world. Every day, all around the globe, specialist electrical installation firms are using<br />
professional systems and products from the comprehensive <strong>OBO</strong> range. Millions of satisfied customers and users, who can<br />
be sure that <strong>OBO</strong> will always provide them with up-to-date professionally correct products <strong>for</strong> practically every field of electrical<br />
installation. Present all over the world – available round the clock: <strong>OBO</strong> also offers first-hand in<strong>for</strong>mation on the World Wide<br />
Web at www.obo-ackermann.com.<br />
2
Everything? At once? Welcome to <strong>OBO</strong> on the Internet<br />
Lightning-fast and up to date: your contact with <strong>OBO</strong> over the Net of Nets. On <strong>OBO</strong>’s Internet pages, customers and<br />
users can find summaries of our product ranges and in<strong>for</strong>mation about new products. Up-to-date course programmes<br />
and seminars at the <strong>OBO</strong> training centre and at our branch offices are there, too.<br />
<strong>OBO</strong> on the Internet: that means even more in<strong>for</strong>mation, even more power and even more speed. Please visit our site.<br />
www.obo-ackermann.com.<br />
3
<strong>OBO</strong>. Used by professionals.<br />
<strong>OBO</strong> understands what professionals need: perfect solutions <strong>for</strong> all aspects of an electrical installation.<br />
User-friendly, practical products <strong>for</strong> fast, uncomplicated installation a comprehensive training<br />
programme and the <strong>OBO</strong> expert hotline <strong>for</strong> on-the-spot assistance at the construction site. <strong>OBO</strong>, the<br />
brand with the hot wire to the customer.<br />
<strong>Systems</strong><br />
Quality<br />
Conducting electricity, routing data, controlling energy –<br />
carrying a complete range of over 30,000 articles, <strong>OBO</strong><br />
offers user-friendly products and practical solutions <strong>for</strong> a<br />
professional data and electrical infrastructure in electrical<br />
installations. And as anyone working with <strong>OBO</strong><br />
quality products knows, one goes hand in glove with the<br />
other. Versatility coupled with integrated thinking –<br />
something we as a systems manufacturer take <strong>for</strong><br />
granted.<br />
4
<strong>OBO</strong> BETTERMANN has subsidiaries, regional<br />
branches and representatives in over 50 countries. All<br />
centres ensure that <strong>OBO</strong> gets to the customer faster<br />
and better.<br />
Experts in their field, <strong>OBO</strong> staff provide professional<br />
support and advice: with solutions, application tips and<br />
hints and practical seminars in <strong>OBO</strong> centres and<br />
branches.<br />
Local<br />
Support & Advice<br />
Seamless and complete programme <strong>for</strong> all aspects<br />
of an electrical installation<br />
Over 30,000 items in seven product units<br />
On-going product maintenance and further<br />
development<br />
Proprietary development and production facilities<br />
Professionals demand quality. A quality offered by<br />
all <strong>OBO</strong> brand products and services:<br />
QA certification to DIN EN ISO 9001:2000<br />
Tested material and manufacturing quality<br />
Numerous national and international test seals<br />
and certificates: GS and VDE marks, UL approvals<br />
Active involvement in national and international<br />
standardisation bodies<br />
Perfect logistical solutions <strong>for</strong> packing and shipping<br />
applications<br />
All products in this catalogue are CE-compliant.<br />
This also applies to standard parts such as screws<br />
and nuts, which are components of the respective<br />
product system.<br />
5
Just when...<br />
. . . we think we’ve achieved a lot, it’s time to take the next step. This is the motto <strong>OBO</strong> BETTERMANN followed<br />
when it bought out the ACKERMANN <strong>Cable</strong> <strong>Management</strong> division of Honeywell. Having bought DAHL<br />
KANAL in 2005, this new acquisition was the next logical step in expanding the sustainable and technically<br />
demanding business divisions to become a system supplier <strong>for</strong> cable management. The <strong>OBO</strong> BETTERMANN<br />
Group is Germany’s market leader in this sector, and ranks among the top three in Europe.<br />
<strong>OBO</strong> BETTERMANN, DAHL and ACKERMANN are system<br />
partners <strong>for</strong> all electrical and databased solutions in office,<br />
residential and industrial buildings, and <strong>for</strong> infrastructure<br />
applications. Ackermann is being continued as an independent<br />
brand, with market leadership <strong>for</strong> cable management in<br />
office and residential buildings being selectively expanded.<br />
For <strong>OBO</strong> BETTERMANN, the competition buyout with other<br />
parties means continuing almost a century of history as an<br />
owner-managed family concern. ACKERMANN has also<br />
followed this tradition <strong>for</strong> several decades.<br />
ACKERMANN has a modern production facility, top-quality<br />
products and advantages over its competitors. Under the<br />
auspices of the <strong>OBO</strong> BETTERMANN family concern, synergy<br />
effects have been achieved to the benefit of both parties<br />
since early 2006.<br />
6
Our goal is to present to our customers, today and in the<br />
future, the technically most advanced innovations and enjoy<br />
the greatest possible presence on the market to deal with<br />
their day-to-day requirements. This is the <strong>OBO</strong> mission.<br />
Orange connects the <strong>OBO</strong> BETTERMANN, DAHL and<br />
ACKERMANN brands. So they will be making their debut<br />
on the market in orange – the colour of energy and<br />
pleasure. Think orange, think connected!<br />
Your ‘Bettermen’, staff and family<br />
7
Think connected<br />
Integrated thinking <strong>for</strong> perfected solutions in all areas of electrical installation.<br />
In other words, <strong>Cable</strong> <strong>Management</strong> by <strong>OBO</strong>: intelligent, flexible systems <strong>for</strong> tomorrow’s energy and data<br />
infrastructure, <strong>for</strong> industrial and infrastructure projects, as well as residential and commercial constructions<br />
of every magnitude. One goes hand in glove with the other – from highly stressable cable support systems to<br />
functional <strong>underfloor</strong> and conductor routing systems with optimally matched installation systems through to<br />
the <strong>OBO</strong> Construct KTS planning software. Our broad range of functional maintenance, MLAR and fire<br />
protection systems guarantee the required speed.<br />
<strong>Cable</strong> support systems<br />
The extensive <strong>OBO</strong> KTS range offers a broad spectrum of different<br />
product lines, from cable ducts to wide span systems<br />
through to light carrier rails <strong>for</strong> practically every field of application.<br />
The product range comprises cable support systems<br />
made from quality galvanised steel, as well as variants from<br />
stainless steel materials.<br />
<strong>OBO</strong> also offers solutions <strong>for</strong> special purpose applications.<br />
These include made-to-measure and special designs, as well<br />
as cable support systems with extremely resistant plastic<br />
coating <strong>for</strong> optimised corrosion protection in aggressive atmospheres.<br />
The KTS product segment is rounded out by a<br />
range of practical accessories.<br />
8
Fire protection systems<br />
Preventive fire protection is key to guaranteeing safety in<br />
buildings. <strong>OBO</strong> offers a complete range of professional<br />
products <strong>for</strong> every application in building protection technology<br />
– <strong>Cable</strong> <strong>Management</strong> offers you well-engineered function<br />
maintenance and MLAR systems.<br />
<strong>Cable</strong> routing systems<br />
The technical infrastructure of industrial buildings, offices and<br />
even residential buildings is becoming increasingly complex<br />
and is calling <strong>for</strong> cable routing and device installation. <strong>OBO</strong><br />
offers an extensive range of future-orientated solutions that<br />
meets every requirement <strong>for</strong> flexibility and design as well as<br />
functionality and ease of installation. LFS systems from <strong>OBO</strong><br />
and Ackermann are complemented by the perfectly compatible<br />
EGS installation device systems.<br />
Installation device systems<br />
The modern installation device systems from <strong>OBO</strong> will win you<br />
over with their high degree of functionality and attractive<br />
shape. The range includes practical product and design lines<br />
<strong>for</strong> every conceivable use and application.<br />
Underfloor systems<br />
Underfloor systems offer convenient, safe access to power<br />
supply, internal and external data networks as well as to<br />
telecommunications equipment. Extremely elegant: the cable<br />
routing system concealed under the floorboard. The complete<br />
range includes solutions <strong>for</strong> every type of floor system and<br />
field of application.<br />
9
®<br />
<strong>Cable</strong> <strong>Management</strong> by <strong>OBO</strong> <strong>for</strong><br />
residential and administration buildings<br />
Modern building technology and higher demands on living com<strong>for</strong>t have fundamentally changed electrical<br />
installation in private houses and residential buildings. The days of “just a few sockets and switches” are long<br />
gone. Nowadays, links to modern telecommunication and data services are a must, even in private dwellings.<br />
The same goes <strong>for</strong> administration buildings that have to be equipped not only with an efficient power supply,<br />
but also with complex data and communication networks.<br />
Rapid skirting duct system<br />
Creating the maximum of space in the smallest of rooms – this<br />
is the benefit offered by <strong>OBO</strong>’s Rapid 45 duct: compact<br />
design with 45 mm cover, high-quality aluminium body, anodised<br />
or coated to RAL, also available in white plastic or aluminium-look,<br />
fast device installation without sockets.<br />
Device installation duct systems<br />
Choose from a range of profiles and duo-ducts with separate<br />
data section. All RAL colours, powder-coatings and special<br />
lengths of up to 3 m (up to 6 m <strong>for</strong> aluminium) are possible. The<br />
elegant systems are complemented by a space-saving and fastinstallation<br />
range of devices in the Modul 45 adapter technology.<br />
10
Media columns<br />
Media columns are particularly suitable <strong>for</strong> administration buildings<br />
and offices. Installed at intersections or at the workstation<br />
itself, they can be easily “tapped” at any time. Flexible<br />
solutions in true <strong>OBO</strong> style: functional, elegant, in different profile<br />
variants and lengths of up to 6 m. In all RAL colours or anodised<br />
and fully pre-assembled and pre-wired on request.<br />
Underfloor systems<br />
The <strong>underfloor</strong> systems lend <strong>OBO</strong>’s <strong>Cable</strong> <strong>Management</strong> real<br />
style. They are concealed in the floor and make power, data<br />
and telecommunication networks invisible. Data floor outlets<br />
and/or media columns guarantee perfect connection options.<br />
This product range spans screed-covered ducts to screedflush<br />
systems through to cavity and false-floor systems.<br />
Modul 45 range<br />
Extremely compact and quick to install: Modul 45 type installation<br />
devices. Switches and sockets are simply clipped into<br />
position, – and remain available at all times should the installation<br />
be modified at a later date. Can be used <strong>for</strong> device installation<br />
ducts, <strong>underfloor</strong> systems, media columns and<br />
Deskbox.<br />
The final metre to the desk<br />
Flex duct and Deskbox mean the final metres to the desk can<br />
also be bridged easily and intelligently. Flex duct routes cables<br />
to the desk, Deskbox brings data and communication connections,<br />
sockets and switches elegantly and functionally<br />
within reach.<br />
11
Work safely and live com<strong>for</strong>tably<br />
®<br />
with <strong>OBO</strong> systems<br />
<strong>OBO</strong> <strong>Cable</strong> <strong>Management</strong> products have been tried and proven <strong>for</strong> many years in numerous residential and<br />
administration buildings around the world. <strong>Systems</strong> guaranteeing that we can work safely and com<strong>for</strong>tably.<br />
Modern buildings are growing in complexity, because future-oriented building system technology requires a<br />
highly efficient electrical installation. <strong>OBO</strong>’s bespoke solutions provide the ideal basis.<br />
Residential and administration buildings<br />
Dubai: 100 kilometres of cable support systems. Berlin: ten<br />
kilometres of cable routing systems. Nuremberg: 1,500 installation<br />
devices. Munich: 7,000 m of <strong>underfloor</strong> ducts, 1,500<br />
<strong>underfloor</strong> connection sockets, over 1,000 stainless steel cassettes.<br />
These numbers demonstrate the extent to which the<br />
demands on a contemporary electrical installation in modern<br />
administration buildings have grown. Thanks to the perfect alliance<br />
between engineering, production and logistics, <strong>OBO</strong> is<br />
able to perfectly execute even highly-complex projects.<br />
Numerous examples pay testimony to the expertise and abilities<br />
of <strong>OBO</strong> and Ackermann in this specialist field, too. These<br />
examples range from office buildings of the German Federal<br />
government in Cologne, Bonn and Berlin to the European<br />
Parliament in Brussels to office complexes of renowned<br />
organisations such as IBM, Commerzbank, Gruner & Jahr and<br />
Deutsche Telekom.<br />
12
Technical equipment in private houses and residential buildings<br />
is also growing in complexity. As well as the power<br />
supply, telecommunication and data networks <strong>for</strong> e-mail and<br />
the Internet are also playing a greater role. This is where <strong>OBO</strong><br />
scores, with experience garnered from large-scale industrial<br />
and infrastructure projects. The flexibility and adaptability of<br />
<strong>OBO</strong> <strong>Cable</strong> <strong>Management</strong> systems create solutions that are<br />
perfectly matched to individual requirements in this field, too.<br />
13
If you have big plans, you need a<br />
strong partner<br />
True to this motto, <strong>OBO</strong> project and system technology professionals realise cable management solutions of<br />
every magnitude <strong>for</strong> industrial and administration buildings and plant engineering and construction, where<br />
the most exacting requirements are placed on quality, functionality, flexibility and professionalism. Benefit<br />
from our experience as a global group with branch offices and agents in over 50 countries around the world.<br />
The planner is our partner.<br />
We understand your plans. We have professionals with<br />
a keen sense of the unusual<br />
Experience, expertise and the feeling <strong>for</strong> the peculiarities of a<br />
project. Our specialists are your reliable and professional partner<br />
at every stage of a project. Bespoke planning is a challenge<br />
that our project and system technology professionals<br />
enjoy squaring up to every day.<br />
14
We understand your visions<br />
Interdisciplinary engineering benefits from synergies<br />
An experienced supplier of complete electrical installations,<br />
<strong>OBO</strong> sees every project as a whole. Interdisciplinary engineering<br />
under just one roof creates the ideal preconditions <strong>for</strong> perfect<br />
solutions that take every aspect into account. Proprietary<br />
manufacturing facilities both at home and abroad enable every<br />
special solution and bespoke product to be created.<br />
Think, plan, make<br />
Everything about <strong>Cable</strong> <strong>Management</strong> by <strong>OBO</strong> revolves around<br />
good connections. And that doesn’t only apply locally on site,<br />
but also in the wider sense to project management within the<br />
<strong>OBO</strong> organisation. The direct association between<br />
planning, engineering and production, coupled with an<br />
efficient IT system guarantee a high degree of flexibility and<br />
swift reactions, from the first planning stage right through to<br />
realisation.<br />
15
Think orange. Think connected.<br />
Strong brands under one roof.<br />
Just when you think you have achieved a lot, it is time to take the next step. This flexibility has been the<br />
core of our thoughts and actions <strong>for</strong> almost 100 years. Combining tradition with vision – that’s “think<br />
orange”. As a system manufacturer, <strong>OBO</strong>’s thoughts and actions are more integrated than ever be<strong>for</strong>e.<br />
The ability to do this is the basis of complete solutions <strong>for</strong> building system technology. Connect products<br />
with system solutions – “think connected”.<br />
We connect ideas with realisation<br />
“I hear and I <strong>for</strong>get. I see and I remember. I do and I understand”<br />
(Confucius). True to this guiding principle, every day we<br />
convert new knowledge into actions and expertise into<br />
tangible solutions. We develop and manufacture our products<br />
ourselves. This way, we can guarantee that our standards are<br />
continuously met, from the idea to the realisation. And we also<br />
guarantee that our customers’ experience is contributed<br />
directly to product development.<br />
We connect our customers with our expertise<br />
Our connection to the customer is always direct and guaranteed<br />
by a dense network of branch offices, agents and<br />
subsidiaries on every continent. Our local field service ensures<br />
that <strong>OBO</strong> expertise can be used by customers everywhere. It<br />
goes without saying that we also attend all the major trade<br />
fairs.<br />
<strong>OBO</strong> seminars, training courses and planner days convey not<br />
only developments, trends and standards, but also theoretical<br />
principles and practical tips and hints. And if you want direct<br />
answers to your questions on a day-to-day basis, just call our<br />
Technical Hotline.<br />
16
In<strong>for</strong>mation<br />
The 2006 Complete Catalogue has a new structure.<br />
Completely revised, the topics of cable routing and device<br />
installation are much clearer. The most common<br />
types of installation are described on fold-out pages (e.g.<br />
Pages 20-22) and provide assistance in the selection<br />
and compilation of the installation systems.<br />
Delivery shall take place solely in the units (pieces or<br />
metres) given in the catalogue and in the specified minimum<br />
order quantity (MOQ).<br />
Our deliveries are subject to the “General conditions<br />
of delivery <strong>for</strong> products and services of the electronics<br />
industry” together with our “Sales and delivery conditions”.<br />
Our printed material provides all in<strong>for</strong>mation in<br />
good faith, but any in<strong>for</strong>mation given shall not be legally<br />
binding.<br />
We reserve the right to make deviations to the figures and<br />
texts as well as changes, which aid the further<br />
development of our products.<br />
All rights reserved. Reprinting – even of individual sections<br />
– only with written approval.<br />
The ordering section contains the following details:<br />
Art. no. Code MOQ SI TI<br />
T<br />
L<br />
B<br />
mounting box - GB2 -<br />
“empty”, suitable <strong>for</strong> the installation of<br />
two individual installation units, with<br />
two strain relief devices <strong>for</strong> incoming<br />
and outgoing conductors.<br />
Dimensions:<br />
W x D x L in mm: 76 x 39 x 165.<br />
30354 A GB2 1 x –<br />
18
Contents<br />
Overview, in<strong>for</strong>mation pages 21 - 37<br />
Overview<br />
In<strong>for</strong>mation pages<br />
EÜK – Screed covered duct system 38 - 57<br />
EÜK – screed covered<br />
duct system<br />
OKA/T - Open flushfloor trunking system 58 - 69<br />
OKA/T – open flushfloor<br />
trunking system<br />
RFT - Raised floor trunking system 70 - 73<br />
Raised floor<br />
trunking system<br />
Service units 74 - 97<br />
Service units<br />
Planning data 98 - 108<br />
Planning data<br />
MOQ = minimum order quantity<br />
General in<strong>for</strong>mation and certificates 109<br />
SI<br />
= <strong>for</strong>m stock available<br />
TI<br />
= pages with additional<br />
technical in<strong>for</strong>mation<br />
In<strong>for</strong>mation<br />
19
New products 2006<br />
Iron grey<br />
RAL 7011<br />
Sepia brown<br />
RAL 8014<br />
Height adjustable cassette with<br />
cord outlet <strong>for</strong> installation of 4 or 9<br />
installation units in dry-cleaned<br />
floors.<br />
Height adjustable cassette with<br />
tube <strong>for</strong> installation of 4 or 9 installation<br />
units in wet-cleaned floors.<br />
Grey beige<br />
RAL 1019<br />
Graphiteyblack<br />
RAL 9011<br />
Junction and branch box <strong>for</strong> screed<br />
heights 120 to 170 mm and 170 to<br />
220 mm.<br />
Metal tube <strong>for</strong> installation in cassettes<br />
<strong>for</strong> wet-cleaned floors.<br />
Light grey<br />
RAL 7035<br />
Cream white<br />
RAL 9001<br />
Unique design of the<br />
round service units <strong>for</strong> installation<br />
environments: <strong>underfloor</strong> cable<br />
trunking systems, raised floor,<br />
cavity floor.<br />
Service units with hinged cover<br />
made of polyamide and aluminium<br />
<strong>for</strong> nine individual accessories with<br />
10 mm floor covering recess.<br />
This colour card contains print reproductions of the standard<br />
colours used <strong>for</strong> our electrical installation systems<br />
according to the colour index RAL 840 HR. Variations between<br />
the print reproductions and the original colour shades<br />
do not give any entitlement to compensation claims.<br />
Original colour cards are available on request <strong>for</strong> the<br />
“te li flur” colours.<br />
St = Steel, Al = Aluminium, PVC = Plastic.<br />
20
Overview, in<strong>for</strong>mation pages<br />
Screed-covered electrical installation systems EÜK<br />
<strong>for</strong> installation of devices in service units GES 22 - 25<br />
Screed-covered electrical installation systems EÜK<br />
<strong>for</strong> installation of devices in square cassettes 26 - 29<br />
Installation of devices in height adjustable cassettes<br />
<strong>for</strong> screed-covered electrical installation systems<br />
EÜK and raised floors. 30 - 33<br />
Installation of devices in cassettes <strong>for</strong> areas<br />
with high traffic loads in electrical installation systems EÜK 34 - 37<br />
21
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of<br />
devices in service units GES<br />
EÜK - Screed-covered duct system<br />
with <strong>underfloor</strong> junction and branch box UZD<br />
Installation of devices in service units<br />
22
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of<br />
devices in service units GES<br />
Installation overview<br />
System overview<br />
Sockets and corresponding<br />
cover plates<br />
GB2: Page 92<br />
GB3: Page 94<br />
Installation of third-party<br />
units<br />
GB2: Page 93<br />
GB3: Page 95<br />
Mounting Tray<br />
Page 97<br />
Service unit<br />
Page 80-91<br />
Mounting lid<br />
Page 44-45<br />
Stacking frame<br />
(optional) Page 40-41<br />
Screed-covered duct<br />
system<br />
Page 40-41<br />
VDE- ÖVE- KEMA-<br />
- EÜK- VDE- ÖVE- KEMA- KEUR-<br />
A- KEUR - ACKERMANN<br />
ACKERMANN - EÜK- VDE- ÖVE-<br />
23
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of<br />
devices in service units GES<br />
Technical data<br />
Nominal compartment widths in brackets<br />
2 Compartment<br />
3 Compartment<br />
2 Compartment<br />
3 Compartment<br />
Number of conductors to be laid in a duct<br />
Filling factor: 50 %<br />
All dimensios in mm<br />
Compartment width 70 mm 80 mm 90 mm 110 mm 120 mm 140 mm<br />
Compartment height 28 38 48 28 38 48 28 38 48 28 38 48 28 38 48 28 38 48<br />
Conductor diameter in mm<br />
5 35 49 63 40 55 71 45 62 80 55 77 98 60 84 107 70 98 126<br />
6 24 34 44 28 38 49 31 43 56 38 53 68 42 58 75 49 68 87<br />
7 18 25 32 20 28 36 23 32 41 28 39 50 31 43 55 36 50 64<br />
8 14 19 25 16 22 28 18 24 31 22 30 38 24 33 42 27 38 49<br />
9 11 15 19 12 17 22 14 19 25 17 24 30 19 26 33 22 30 39<br />
10 9 12 16 10 14 18 11 16 20 14 19 25 15 21 27 18 24 31<br />
11 7 10 13 8 11 15 9 13 17 11 16 20 12 17 22 15 20 26<br />
12 6 9 11 7 10 12 8 11 14 10 13 17 10 15 19 12 17 22<br />
13 5 7 9 6 8 11 7 9 12 8 11 15 9 12 16 10 14 19<br />
14 4 6 8 5 7 9 6 8 10 7 10 13 8 11 14 9 12 16<br />
15 4 5 7 4 6 8 5 7 9 6 9 11 7 9 12 8 11 14<br />
16 3 5 6 4 5 7 4 6 8 5 7 10 6 8 10 7 10 12<br />
17 3 4 5 3 5 6 4 5 7 5 7 9 5 7 9 6 8 11<br />
18 3 4 5 3 4 5 3 5 6 4 6 8 5 6 8 5 8 10<br />
Usable cross-sections S2/S3<br />
Compartment width in mm Short height in mm Usable cross-section<br />
Compartment 1 Compartment 2 Compartment 3 Description A1 in mm 2 A2 in mm 2 A3 in mm 2<br />
S2/19028 28 1989 2754<br />
80 110 S2/19038 38 2769 3834<br />
S2/19048 48 3549 4914<br />
S2/25028 28 2754 3519<br />
110 140 S2/25038 38 3834 4899<br />
S2/25048 48 4914 6279<br />
S3/25028 28 2244 1759 2244<br />
90 70 90 S3/25038 38 3124 2449 3124<br />
S3/25048 48 4004 3139 4004<br />
S3/35028 28 3009 2779 3009<br />
120 110 120 S3/35038 38 4189 3869 4189<br />
S3/35048 48 5369 4914 5369<br />
Material<br />
Technical data<br />
Duct galvanised sheet steel, zinc coating of 275 g/m 2<br />
UZD/UGD<br />
<strong>underfloor</strong> box made of sheet steel, frame made of diecast zinc corners connected<br />
with extruded aluminium sections<br />
Installation cover<br />
sheet steel, galvanised, 4 mm<br />
Levelling range<br />
UZD/UGD levellable to 70-120,120-170 or 170-220 mm; stacking frame with 35 mm fixed height<br />
Minimum installation depth 70 mm <strong>for</strong> service units and with 5 mm floor covering recess<br />
75 mm <strong>for</strong> GRAF9 and service units GES with 10 mm floor covering recess<br />
Application<br />
office and administrative buildings<br />
Load capacity<br />
screed-flush sections of the cable management system and service units<br />
correspond to DIN VDE 0634 Part 1 and Part 2.<br />
Moisture protection<br />
service units GES only <strong>for</strong> dry-cleaned floors<br />
GRAF 9 service unit <strong>for</strong> dry and wet-cleaned floors<br />
24
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of<br />
devices in service units GES<br />
System overview<br />
System overview<br />
c<br />
b<br />
f<br />
b<br />
i<br />
j<br />
g<br />
e<br />
a<br />
h<br />
d<br />
a<br />
b<br />
a<br />
b<br />
a Underfloor installation duct,<br />
3-compartment system<br />
b Coupler<br />
c Vertical bend<br />
d Underfloor box, empty<br />
(<strong>for</strong> installation of a service outlet box)<br />
e Stacking frame<br />
f Service outlet box GES6<br />
g telitank T8NL<br />
h Rough concrete<br />
i Screed<br />
j Floor covering<br />
Note! The following points must be considered be<strong>for</strong>e laying the carpet.<br />
Be<strong>for</strong>e laying the carpet, it should be determined<br />
whether the <strong>underfloor</strong> box serves as a<br />
“junction box” (Fig. ) or “service box” (Fig. ).<br />
Depending on this function, a corresponding<br />
cover has to be inserted to replace the protective<br />
cover. This will determine where the floor<br />
covering is cut.<br />
<br />
A<br />
<br />
B<br />
“Junction box” (UZD 190 only)<br />
When used as a junction box with floor guide<br />
frame (BAU), the complete surface of the<br />
mounting plate has to be cut out of the floor<br />
covering.<br />
“Service box” UGD<br />
Only the surface of the cover blank plate B has<br />
to be cut out of the carpet.<br />
Insertion of the final cover<br />
Currect cutting of the floor<br />
Covering<br />
Additional remark<br />
A<br />
B<br />
We would ask you to appreciate that your<br />
wholesaler may not be able to offer complete<br />
mounting boxs,<br />
due to the range of combination options and<br />
limited storage capacity, but instead offers<br />
“<strong>underfloor</strong> sockets” and function covers as<br />
separate items.<br />
The final cover can only be inserted after setting<br />
of the screed and removal of protection<br />
cover.<br />
Apparatus installation outlet,<br />
closed by cover blanking plate.<br />
Depending on the application, use either A<br />
along the outer edge of the mounting cover or<br />
B according to size of mounting plate aperture.<br />
The duct system<br />
corresponds to DIN VDE 0634<br />
Part 1 and Part 2.<br />
25
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of devices<br />
in square cassettes<br />
EÜK - Screed-covered duct system<br />
Underfloor junction and branch box UZD<br />
Installation of devices in UZD beneath<br />
cassettes with MSRK mounting set<br />
26
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of devices<br />
in square cassettes<br />
Installation overview<br />
Installation of third-party units<br />
GB2: Page 93<br />
GB3: Page 95<br />
Sockets and corresponding<br />
cover plates<br />
GB2: Page 92<br />
GB3: Page 94<br />
Mounting Tray<br />
Page 48-51<br />
Mounting set<br />
Page 48-51<br />
RK cassette<br />
Page 50-51<br />
RKS cassette<br />
Page 48-49<br />
RKF cassette<br />
Page 50-51<br />
Stacking frame (optional)<br />
Page 40-41<br />
VDE- ÖVE- KEMA-<br />
ACKERMANN - EÜK- VDE- ÖVE-<br />
- EÜK- VDE- ÖVE- KEMA- KEUR-<br />
Screed-covered duct<br />
system<br />
Page 40-41<br />
A- KEUR - ACKERMANN<br />
27
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of devices<br />
in square cassettes<br />
Technical data<br />
Number of conductors to be laid in one duct = See Page 24<br />
Usable duct cross-section in mm 2 = See Page 24<br />
Technical data<br />
Material<br />
Duct Galvanised sheet steel, zinc coating of 275 g/m 2<br />
UZD/UGD<br />
Box made of sheet steel, superstructure frame made of diecast zinc corners<br />
connected with extruded aluminium sections<br />
Cassette frame Stainless steel (V2A) 2 mm or brass (MS) 2 mm<br />
Cassette<br />
Stainless steel (V2A) 2 mm or brass (MS) 2 mm, with 4 mm pressure plate made of sheet steel<br />
Tube<br />
Polyamide with V2A or MS cover, aluminium Tube<br />
Levelling range<br />
UZD/UGD levellable 70 - 120, 120 - 170 or 170 - 220 mm;<br />
stacking frame with 35 mm fixed height<br />
Minimum installation depth UZD190 UZD250-2/350-2<br />
A) RKS with VDE mounting tray = 85 mm = 90 mm<br />
B) RKS with BS mounting tray = 70 mm = 125 mm*<br />
C) RKF with VDE mounting tray = 125 mm = 125 mm*<br />
D) RKF with BS mounting tray = 110 mm = 110 mm* (screed = 90 mm*)<br />
* For installation heights between 85 and 115 mm, the middle mounting box cannot be<br />
used, and <strong>for</strong> installation heights of 115 to 125 mm, the middle mounting box can only be fitted<br />
with sockets. Dimensions measured from bare concrete to OKFF.<br />
Application<br />
Load capacity<br />
Moisture protection<br />
Office and administrative buildings, heavy-duty applications only with additional extensions<br />
Screed-flush sections of the duct system and cassettes correspond<br />
to DIN VDE 0634 Part 1 and Part 2<br />
RKS cassettes (with cord outlet) <strong>for</strong> dry-cleaned floors<br />
RK, RKF and BEK/F cassettes <strong>for</strong> dry and wet-cleaned floors<br />
28
Screed-covered electrical installation<br />
systems EÜK <strong>for</strong> installation of devices<br />
in square cassettes<br />
Installation<br />
Cassette solutions <strong>for</strong> junction<br />
boxes and service boxes in floors<br />
with hard floorings<br />
The cassette solutions are designed<br />
<strong>for</strong> use in dry rooms. The<br />
range includes cassettes with a<br />
centre tube cord outlet <strong>for</strong> floors<br />
which are mopped and versions<br />
with a edge cord outlet <strong>for</strong> drycleaned<br />
floors, plus blanking<br />
cassettes. They fulfil all the requirements<br />
of DIN VDE with respect<br />
to moisture protection and loadbearing<br />
capability. The narrow<br />
cassette frame fits flush with the<br />
floor covering after it is laid.<br />
The cables are protected and<br />
tread-proof, either by means of<br />
the edge cord outlet (<strong>for</strong> drycleaned<br />
floors) or by means of a<br />
centre tube cord outlet (<strong>for</strong> mopped<br />
floors). Cassettes of different<br />
heights are available to suit different<br />
flooring thicknesses.<br />
5.<br />
3.<br />
1.<br />
4.<br />
2.<br />
3 mm<br />
Mounting the cassette solutions on <strong>underfloor</strong><br />
junction and branch box UZD<br />
Cassette frame<br />
Cassette<br />
Cassette solutions – number<br />
of mounting boxes which can<br />
be fitted<br />
For the RKS cassette with edge<br />
cord outlet, up to three mounting<br />
boxes (GB2, GB3) can be fitted<br />
into the UZD 250-2 and 350-2.<br />
This means the screed height<br />
must be at least 75 mm.<br />
For the cassette with the RKF<br />
centre tube cord outlet, the number<br />
of mounting boxes also<br />
depends on the available height<br />
“from the top edge of the raw<br />
floor to the top edge of the<br />
screed” (see diagram opposite).<br />
The middle mounting box can<br />
only be used if E = 130 mm. If<br />
there is sufficient installation<br />
depth, a ladder extension (Art.<br />
no. 30768A) must always be<br />
used <strong>for</strong> the middle mounting<br />
box.<br />
E<br />
≥ 75<br />
H<br />
Cassette frame<br />
E<br />
≥ 120<br />
H<br />
Cassette recess = H-2 mm<br />
Underfloor box<br />
UZD..<br />
Cassette<br />
Cassette recess = H-2 mm<br />
Part No.<br />
30768 A<br />
Underfloor box<br />
UZD..<br />
Tube<br />
cord<br />
outlet<br />
Tube<br />
cord<br />
outlet<br />
Rough concrete<br />
Cassette structure on UZD – Adjusting the flooring<br />
thickness on the cassette frame and in the cassette<br />
29
Installation of devices in height adjustable<br />
cassettes <strong>for</strong> screed-covered electrical<br />
installation systems EÜK and raised floors.<br />
System overview<br />
EÜK - Screed-covered duct system<br />
with <strong>underfloor</strong> junction and branch box UZD<br />
Installation of devices<br />
in round cassette<br />
30
Installation of devices in height adjustable<br />
cassettes <strong>for</strong> screed-covered electrical<br />
installation systems EÜK and raised floors.<br />
System overview<br />
Sockets and corresponding<br />
cover plates<br />
GB2: Page 92<br />
GB3: Page 94<br />
Installation of third-party units<br />
GB2: Page 93<br />
GB3: Page 95<br />
Mounting Tray<br />
Page 97<br />
RKFR/RKSR cassette<br />
Page 89<br />
RKFN/RKSN cassette<br />
Page 87<br />
Mounting lid<br />
Page 44-45<br />
Mounting lid<br />
Page 44-45<br />
stacking frame (optional)<br />
Page 40-41<br />
VDE- ÖVE- KEMA-<br />
- EÜK- VDE- ÖVE- KEMA- KEUR-<br />
Screed-covered<br />
duct system<br />
Page 40-41<br />
ACKERMANN - EÜK- VDE- ÖVE-<br />
A- KEUR - ACKERMANN<br />
31
Installation of devices in height adjustable<br />
cassettes <strong>for</strong> screed-covered electrical<br />
installation systems EÜK and raised floors.<br />
Technical data<br />
Number of conductors to be laid in a duct = See Page 24<br />
Usable duct cross-section in mm 2 = See Page 24<br />
Technical data<br />
Material<br />
Duct Galvanised sheet steel, zinc coating of 275 g/m 2<br />
UZD/UGD<br />
Box made of sheet steel, superstructure frame made of diecast zinc corners<br />
connected with extruded aluminium sections<br />
Installation cover Sheet steel, 4 mm<br />
Cassette frame Stainless steel (V2A) 2 mm or brass (MS) 2mm<br />
Cassette<br />
Stainless steel (V2A) 1.5 mm or brass (MS) 1.5 mm, with 4-mm-steel plate<br />
Tube<br />
- Polyamid with V2A or MS cover<br />
- Aluminium<br />
Levelling range<br />
UZD/UGD: 70 - 120, 120 - 170 or 170 -220 mm<br />
stacking frame with 35 mm fixed height<br />
Cassette depth 20 mm: up to 150 mm (with supplied levelling supports)<br />
Cassette depth 25 mm: up to 155 mm (with supplied levelling supports)<br />
Minimum installation depth Round cassettes RKR 105 mm<br />
RKFR* 135 mm<br />
RKFR** 110 mm<br />
RKSR 110 mm<br />
Square cassettes<br />
Floor covering thickness<br />
20 mm 25 mm<br />
RKN 100 mm 105 mm<br />
RKFN* 132 mm 137 mm<br />
RKFN** 105 mm 110 mm<br />
RKSN 105 mm 110 mm<br />
*=Tube made of polyamide; ** = Tube made of metal<br />
Dimensions measured from bare concrete to OKFF<br />
Application<br />
Load capacity<br />
Moisture protection<br />
Office and administrative buildings, heavy-duty applications only with additional<br />
extensions<br />
Screed-flush sections of the duct system and cassettes correspond<br />
to DIN VDE 0634 Part 1 and Part 2<br />
RKRS and RKSN cassettes (with cord outlet) <strong>for</strong> dry-cleaned floors<br />
RKR, RKFR, RKN and RKFN cassettes <strong>for</strong> dry and wet-cleaned floors<br />
32
Installation of devices in height adjustable<br />
cassettes <strong>for</strong> screed-covered electrical installation<br />
systems EÜK and raised floors.<br />
Installation<br />
ø 305<br />
ø 275<br />
ø 215<br />
Adjustable<br />
RKFR RKR<br />
Height E E<br />
Standard max. 150 mm* max. 150 mm*<br />
RKNEV110 145 + 50 mm 145 + 50 mm<br />
RKNEV150 185 + 50 mm 185 + 50 mm<br />
* With the levelling supports contained in the cassette<br />
package<br />
dauerelastische Fugenmasse<br />
permanently elastic sealant<br />
OKFF<br />
E<br />
SW 13<br />
33
Installation of devices in cassettes <strong>for</strong> areas<br />
with high traffic loads in electrical installation<br />
systems EÜK<br />
Square heavy-duty cassette with heavy duty support<br />
in corner areas of <strong>underfloor</strong> junction and branch box UZD<br />
GRAF9 service unit with DUGR9SL mounting lid<br />
and heavy-duty support in UZD350-2<br />
34
Installation of devices in cassettes <strong>for</strong> areas<br />
with high traffic loads in electrical installation<br />
systems EÜK<br />
Installation overview<br />
Installation of third-party units<br />
GB2: Page 93<br />
GB3: Page 95<br />
Sockets and corresponding<br />
cover plates<br />
GB2: Page 92<br />
GB3: Page 94<br />
Mounting set<br />
Page 53<br />
RKRSL cassette<br />
Page 54<br />
RKFRSL cassette<br />
Page 54<br />
RKSL cassette<br />
Page 53<br />
RKFSL cassette<br />
Page 53<br />
Mounting lid<br />
Page 55<br />
Stacking frame (optional)<br />
Page 40-41<br />
Screed-covered<br />
duct system<br />
Page 40-41<br />
Heavy-duty support<br />
Page 53<br />
35
Installation of devices in cassettes <strong>for</strong> areas<br />
with high traffic loads in electrical installation<br />
systems EÜK<br />
Technical data<br />
Number of conductors to be laid in one duct = See Page 24<br />
Usable duct cross-section in mm 2 = See Page 24<br />
Technical data<br />
Material<br />
Duct Galvanised sheet steel, zinc coating of 275 g/m 2<br />
UZD/UGD<br />
Box made of sheet steel, frame made of diecast zinc corners<br />
connected with extruded aluminium sections<br />
Cassette frame<br />
Stainless steel, V2A, 2 mm<br />
Cassette<br />
Stainless steel, V2A, 2 mm, with 4 or 8 mm sheet steel plate<br />
Tube<br />
Polyamide with stainless steel or aluminium cover<br />
Levelling range<br />
UZD/UGD height adjustable to 70 - 120, 120 - 170 or 170 -220 mm<br />
stacking frame with 35 mm fixed height<br />
Minimum installation depth<br />
Square cassettes<br />
RKSL<br />
RKFSL<br />
UZD250-2/350-2<br />
= 90 mm<br />
= 125 mm*<br />
* For installation heights between 85 and 115 mm, the middle mounting box cannot be<br />
used, and <strong>for</strong> installation heights of 115 to 125 mm, the middle mounting box can<br />
only be fitted with power sockets.<br />
Dimensions measured from bare concrete to OKFF<br />
Round cassettes<br />
Floor covering recess<br />
20 mm 25 mm<br />
RKRSL = 105 mm = 109 mm<br />
RKFRSL** = 135 mm = 139 mm<br />
RKFRSL*** = 110 mm = 114 mm<br />
** Tube made of polyamide<br />
*** Tube made of aluminium<br />
Application<br />
Load capacity<br />
Moisture protection<br />
Office and administrative buildings, heavy-duty applications only with<br />
additional extensions<br />
Screed-flush parts of the duct system and cassettes with heavy-duty support up to<br />
max. 20 kN<br />
RKRSL, RKFRSL, RKSL and RKFSL cassettes <strong>for</strong> dry and wet-cleaned floors<br />
36
Installation of devices in cassettes <strong>for</strong> areas<br />
with high traffic loads in electrical installation<br />
systems EÜK<br />
Installation<br />
Overview<br />
In<strong>for</strong>mation pages<br />
Heavy-duty solution with round cassette<br />
Heavy-duty solution with square cassette<br />
Use in heavy-duty areas<br />
The task of cable routing and unit installation occur in areas with high traffic loads,<br />
such as exhibition areas in museums and car showrooms, sales areas, concourses<br />
in airports and stations, workshops, etc.<br />
These areas are commonly referred to as heavy-duty areas, as here the live loads<br />
place additional requirements on the floors and the installation systems. Besides<br />
static <strong>for</strong>ces, dynamic <strong>for</strong>ces may also have an impact, which should be taken into<br />
account in individual cases.<br />
Installation systems and floor coverings – a need <strong>for</strong> harmony<br />
The floor structure, screed type, covering thickness and the floor covering type<br />
– these are all key factors in the selection of the installation systems. Stone or hard<br />
coverings are often used in heavy-duty areas, on account of the applications involved.<br />
These can be cleaned easily and are very resistant to the live loads.<br />
The type of the cleaning required <strong>for</strong> the floor covering has an impact on the selection<br />
of the installation systems. If wet cleaning <strong>for</strong> floors is required, then the covering<br />
must offer moisture protection <strong>for</strong> the cables and resources installed in the floor.<br />
With regard to the covering thickness, the type and thickness of the floor coverings<br />
are of major importance. The smallest of bends can cause thin, hard floor coverings<br />
to break. Thick floor coverings have a positive effect on the load capacity of<br />
systems, as the load is distributed over a wide area.<br />
Note<br />
As the thickness of the floor covering and the load capacity increase, the weight of<br />
the covers of the installation system also increases. As these may require “handling”<br />
in some cases, agreement is required from all involved parties at an early stage.<br />
In the case of smooth floor covering surfaces, suction units are a suitable aid <strong>for</strong><br />
opening covers/cassettes.<br />
If the coverings are uneven or porous, then additional opening aids, such as<br />
threaded sleeves in the cassettes <strong>for</strong> installation keys, can be used.<br />
Standardisation<br />
In the current standard, DIN VDE 0634, load requirements <strong>for</strong> electrical installation<br />
systems are specified only <strong>for</strong> office applications. Although these requirements are<br />
relatively stringent, no products can be tested <strong>for</strong> the so-called heavy-duty sector.<br />
Current applications thus require detailed requirements from consultantes and<br />
construction engineers, and appropriate product testing.<br />
Ackermann – systems <strong>for</strong> the heavy-duty sector<br />
In recent years, Ackermann has worked closely with consultantes and construction<br />
engineers to develop a wide range of individual solutions <strong>for</strong> sectors with increased<br />
load requirements.<br />
As far as possible, these solutions are based on standard products, and tailor<br />
-made solutions are only created <strong>for</strong> the points at which the heavy-dutys impact.<br />
Based on the experience gained, there are now system solutions available <strong>for</strong><br />
screed-flush and screed-covered installation. Flexibility and safety are at the heart of<br />
the development process.<br />
The moisture protection offered by the system corresponds to DIN VDE 0634.<br />
Screed-covered solution<br />
In the two system sizes, 250 and 350, the ducts S2 and S3 are used in the standard<br />
version, along with the UZD box. Additional supports in the box ensure the<br />
necessary stiffness and load capacity.<br />
To provide a cover above the device installation, square or round heavy-load cassettes<br />
are used along with the GRAF9 service unit together with the installation cover<br />
with heavy-load support.<br />
Load classes<br />
The system solution “heavy-duty, screed-covered” is available in two versions:<br />
- Load class 1 <strong>for</strong> static loads of up to 10 kN.<br />
- Load class 2 <strong>for</strong> static loads of up to 20 kN.<br />
- GRAF9 <strong>for</strong> loads of up to 7.5 kN.<br />
37
The screed-covered duct system - EÜK - is used to cover large floor areas in office and administrative buildings<br />
with electrical resources. In the screed, ducts and floor boxes <strong>for</strong>m a (dense) grid and make conductor routing and<br />
installation options available <strong>for</strong> electrical resources.<br />
The EÜK screed-covered duct system is layed, positioned and fastened on the bare concrete. The duct sections<br />
are covered by the screed. The boxes are flush with the screed.<br />
38
EÜK – screed-covered duct system<br />
Ducts, <strong>underfloor</strong> junctions<br />
and branch boxes and<br />
accessories from Page 40 - 43<br />
Mounting cover from Page 44 - 45<br />
Underfloor service box from Page 46<br />
Square cassette solutions from Page 47 - 51<br />
Cassette solutions <strong>for</strong><br />
high traffic load<br />
and accessories from Page 52 - 55<br />
Underfloor outlet box<br />
UDL2/80 and US80 from Page 56<br />
Underfloor box UGE9 and<br />
accessories from Page 57<br />
39
EÜK – Screed-covered duct system<br />
EÜK duct and accessories, <strong>underfloor</strong> junction and<br />
branch box<br />
Duct height<br />
Description<br />
Underfloor box with external height adjustment (UZD or UGD), opening<br />
side walls, pre-punched in accordance with the duct size.<br />
The box can be raised by 35 mm using stacking frames.<br />
Material<br />
Underfloor box body, side walls and installation protection cover made<br />
of pre-galvanised sheet steel. Levelling frame made of<br />
die-cast aluminium.<br />
Delivery condition<br />
Underfloor box adjusted to a screed height of 70 mm.<br />
Notes<br />
– Earth continuity<br />
For the earth continuity, a earth conductor clamp (8AWR)<br />
connection bracket is required <strong>for</strong> the <strong>underfloor</strong> box.<br />
– Underfloor junction and branch box<br />
The inside of the box is sealed against on-site contamination by an<br />
installation protection cover. This installation protection cover must<br />
be replaced with a assembly cover prior to laying the floor covering.<br />
ACKERMANN - EÜK - VDE - ÖVE - KEMA - KE<br />
Underfloor installation duct<br />
– S2/3 compartments –<br />
Standard length supplied = 2m<br />
Material: sheet steel, pre-galvanised<br />
In accordance with DIN 18560,<br />
the minimum screed covering <strong>for</strong><br />
cement screed is 35 mm.<br />
Coupler – VL –<br />
For use as coupler or expansion<br />
joint.<br />
28 mm<br />
38 mm<br />
48 mm<br />
28 mm<br />
38 mm<br />
48 mm<br />
28 mm<br />
38 mm<br />
48 mm<br />
Duct end cap – SE –<br />
To close duct ends.<br />
EÜK – Screed covered<br />
duct system<br />
Nominal compartment widths in brackets<br />
2 Compartment<br />
27mm<br />
37mm<br />
48 mm<br />
2 Compartment<br />
Vertical bend – KV –<br />
To change the direction of the duct.<br />
Leg length 200 mm each.<br />
28 mm<br />
38 mm<br />
48 mm<br />
3 Compartment<br />
28 mm<br />
38 mm<br />
48 mm<br />
3 Compartment<br />
Underfloor junction and branch box – UZD –<br />
As described opposite, <strong>for</strong> ducts with nominal<br />
heights of 28-48 mm.<br />
Important! Be<strong>for</strong>e laying the flooring, read the notes<br />
on Page 25.<br />
Dimensions:<br />
b = box body<br />
B = base plate<br />
Levelling area in mm: 70-120<br />
120-170<br />
170-220<br />
c<br />
q e<br />
h<br />
e<br />
c<br />
Stacking frame – ARU –<br />
To increase height of <strong>underfloor</strong> boxes<br />
by 35 mm each.<br />
Material: die-cast aluminium.<br />
(4 thread stacking pins also supplied).<br />
max. N<br />
a<br />
C<br />
C<br />
Dimensions a c q e h N<br />
UZD [in mm] [in mm] [in mm] [in mm] Nominal width<br />
of the<br />
duct<br />
min max<br />
UZD190 330 270 244 70 120 190<br />
UZD250-2 390 330 284 70 120 190, 250<br />
UZD250-2/120 390 330 284 120 170 190, 250<br />
UZD250-2/170 390 330 284 170 220 190, 250<br />
UZD350-2 490 430 384 70 120 190, 250, 350<br />
UZD350-2/120 490 430 384 120 170 190, 250, 350<br />
UZD350-2/170 490 430 384 170 220 190, 250, 350<br />
Earth conductor clamp – 8AWR –<br />
For use in <strong>underfloor</strong> junction and<br />
branch boxes UZD and <strong>underfloor</strong><br />
empty box UGD.<br />
Material: sheet steel, galvanised, yellow<br />
passivated.<br />
Terminal range: 2 x 1.5 – 4 mm.<br />
Dimensions c e<br />
ARU [in mm] [in mm]<br />
ARU190/35 250 216<br />
ARU250/35-2 330 284<br />
ARU350/35-2A 430 384<br />
40
Duct width 190 mm<br />
Art. no. Code MOQ SI TI<br />
Duct width 250 mm<br />
Art. no. Code MOQ SI TI<br />
Duct width 350 mm<br />
Art. no. Code MOQ SI TI<br />
2-comp:<br />
30001B2 S2/19028 1 X 24<br />
30001D2 S2/19038 1 X 24<br />
30001F2 S2/19048 1 X 24<br />
2-comp:<br />
30002B2 S2/25028 1 X 24<br />
30002D2 S2/25038 1 X 24<br />
30002F2 S2/25048 1 X 24<br />
– – – – –<br />
– – – – –<br />
– – – – –<br />
– – – –<br />
– – – –<br />
– – – –<br />
3-comp:<br />
30002B3 S3/25028 1 X 24<br />
30002D3 S3/25038 1 X 24<br />
30002F3 S3/25048 1 X 24<br />
3-draw:<br />
30003B3 S3/35028 1 X 24<br />
30003D3 S3/35038 1 X 24<br />
30003F3 S3/35048 1 X 24<br />
30008B VL19028 1 X<br />
30008D VL19038 1 X<br />
30008F VL19048 1 X<br />
30009B VL25028 1 X<br />
30009D VL25038 1 X<br />
30009F VL25048 1 X<br />
30010B VL35028 1 X<br />
30010D VL35038 1 X<br />
30010F VL35048 1 X<br />
30044B SES190/27 1<br />
30044D SES190/37 1<br />
30044F SES190/47 1<br />
30045B SES250/27 1<br />
30045D SES250/37 1<br />
30045F SES250/47 1<br />
30046B SES350/27 1<br />
30046D SES350/37 1<br />
30046F SES350/47 1<br />
EÜK – Screed covered<br />
duct system<br />
2-comp:<br />
30024B2 KV2/19028 1 X<br />
30024D2 KV2/19038 1 X<br />
30024F2 KV2/19048 1 X<br />
2-comp:<br />
30025B2 KV2/25028 1 X<br />
30025D2 KV2/25038 1 X<br />
30025F2 KV2/25048 1 X<br />
– – – – –<br />
– – – – –<br />
– – – – –<br />
– – – –<br />
– – – –<br />
– – – –<br />
3-comp:<br />
30025B3 KV3/25028 1 X<br />
30025D3 KV3/25038 1 X<br />
30025F3 KV3/25048 1 X<br />
3-comp:<br />
30026B3 KV3/35028 1 X<br />
30026D3 KV3/35038 1 X<br />
30026F3 KV3/35048 1 X<br />
<strong>for</strong> ducts of 190 mm<br />
<strong>for</strong> ducts of 190 - 250 mm<br />
<strong>for</strong> ducts of 190 - 350 mm<br />
30210A UZD190 1 X<br />
UZD..<br />
30314A ..250-2 1 X<br />
30314C ..120170/250-2 1 X<br />
30314D ..170220/250-2 1 X<br />
UZD..<br />
30312A ..350-2 1 X<br />
30312C ..120170/350-2 1 X<br />
30312D ..170220/350-2 1 X<br />
30282A ARU-190/35 1 X<br />
ARU-..<br />
30336B ..250/35-2 1 X<br />
ARU-..<br />
30336C ..350/35-2 1 X<br />
35083CV 8AWR 10 X 35083CV 8AWR 10 X 35083CV 8AWR 10 X<br />
41
EÜK – Screed-covered duct system<br />
Box divider, Elbow, Crossover<br />
• Application<br />
<strong>Cable</strong> segregation inside junction boxes.<br />
• Material<br />
– Galvanised steel, 1mm.<br />
• Dimensions<br />
Unique crossovers <strong>for</strong> duct height 28 and 38 mm.<br />
• Required no. of crossovers<br />
TEE<br />
CROSS<br />
1 pcs.<br />
1 pcs.<br />
box divider<br />
EÜK – Screed covered<br />
duct system<br />
• Delivery<br />
Single units.<br />
elbow<br />
crossover<br />
crossover Tee-branch<br />
42
Box divider<br />
Elbow<br />
nominal size<br />
190 to 190<br />
190 to 250<br />
250 to 250<br />
<strong>for</strong> UZD250-2<br />
<strong>for</strong> UZD350-2<br />
Art. no. Code MOQ Art. no. Code MOQ<br />
33244A UZD/BD2 1 33244B UZD/BD3 1<br />
UZD/B2/.. 1<br />
33245A ..190190 1 – –<br />
33245A ..190250 1 – –<br />
33245A ..190250 1 – –<br />
Elbow<br />
250 to 250<br />
250 to 350<br />
350 to 350<br />
Crossover <strong>for</strong> Tee-branches,<br />
3-compartment 190 with 190<br />
190 with 250<br />
250 with 250<br />
UZD/B3/..<br />
– – 1 33245C ..250250 1<br />
– – 1 33245D ..250350 1<br />
– – 1 33245E ..350350 1<br />
UZD/C2/..<br />
33283A ..190190 – –<br />
33283A ..190190 – –<br />
33283A ..250250 – –<br />
EÜK – Screed covered<br />
duct system<br />
Crossover <strong>for</strong> Tee-branches,<br />
3-compartment 350 with 350<br />
UZD/C3/..<br />
– – 33283B ..350350 1<br />
Crossover<br />
3-compartment 250 with 250<br />
Crossover<br />
3-compartment 350 with 350<br />
UZD/C2/..<br />
33280A ..250250 1 – –<br />
UZD/C3/.. 1<br />
– – 33280B ..350350 1<br />
43
EÜK – Screed-covered duct system<br />
Accessories <strong>for</strong> use of the <strong>underfloor</strong> junction and<br />
branch box UZD as an <strong>underfloor</strong> service box UGD<br />
Options <strong>for</strong> use as service box<br />
Mounting lid – DUG.2 –<br />
<strong>for</strong> fitting a service outlet GESRM 2.<br />
Material: 4 mm steel, pre-galvanised.<br />
D<br />
D<br />
Blanking cover plate – DUG-B. –<br />
suitable <strong>for</strong> the above mountig cover.<br />
Material: 3 mm steel, pre-galvanised.<br />
Mounting cover– DUG.RM2 –<br />
<strong>for</strong> fitting a service outlet GESRM 2.<br />
Material: 4 mm steel, pre-galvanised.<br />
EÜK – Screed covered<br />
duct system<br />
D<br />
D<br />
Mounting lid– DUG.6 –<br />
<strong>for</strong> fitting a service outlet GES4 or a junction<br />
box ZES4 or a square cassette size 4.<br />
Material: 4 mm steel, pre-galvanised.<br />
Blanking cover plate – DUG-B. –<br />
suitable <strong>for</strong> the above mountig cover.<br />
Material: 3 mm steel, pre-galvanised.<br />
Mounting lid – DUG.R4 –<br />
<strong>for</strong> fitting a service outlet GESR4 or a junction<br />
box ZESR4 or a round cassette size R4.<br />
Material: 4 mm steel, pre-galvanised.<br />
D<br />
D<br />
Blanking cover plate – DUG-B. –<br />
suitable <strong>for</strong> the above mountig cover.<br />
Material: 3 mm steel, pre-galvanised.<br />
Mounting lid – DUG.6 –<br />
<strong>for</strong> fitting a service outlet GES6 or a<br />
junction box ZES6.<br />
Material: 4 mm steel, pre-galvanised.<br />
D<br />
D<br />
Blanking cover plate – DUG-B. –<br />
suitable <strong>for</strong> the above mountig cover.<br />
Material: 3 mm steel, pre-galvanised.<br />
Mounting lid – DUG.R7 –<br />
<strong>for</strong> fitting a service outlet GESR7 or a junction<br />
box ZESR7or a round cassette size R7.<br />
Material: 4 mm steel, pre-galvanised.<br />
D<br />
D<br />
Blanking cover plate – DUG-B. –<br />
suitable <strong>for</strong> the above mountig cover.<br />
Material: 3 mm steel, pre-galvanised.<br />
Mounting lid – DUG.9 –<br />
<strong>for</strong> fitting a service outlet GESR9 or a junction<br />
box ZES9 or a square cassette size 9.<br />
Material: 4 mm steel, pre-galvanised.<br />
D<br />
D<br />
Blanking cover plate – DUG-B. –<br />
suitable <strong>for</strong> the above mountig cover.<br />
Material: 3 mm steel, pre-galvanised.<br />
Mounting lid – DUG.R9 –<br />
<strong>for</strong> fitting a service outlet GESR9 or a junction<br />
box ZESR9 or a round cassette size R9.<br />
Material: 4 mm steel, pre-galvanised.<br />
D<br />
D<br />
Blanking cover plate – DUG-B. –<br />
suitable <strong>for</strong> the above mountig cover.<br />
Material: 3 mm steel, pre-galvanised.<br />
44
Nominal size 190 mm <strong>for</strong> UZD 190-2<br />
Art. no. Code MOQ SI TI<br />
Nominal size 250 mm <strong>for</strong> UZD 250-2<br />
Art. no. Code MOQ SI TI<br />
Nominal size 350 mm <strong>for</strong> UZD 350-2<br />
Art. no. Code MOQ SI TI<br />
DUG190/..<br />
59993 ..GES2-1 1 X<br />
D = 243 mm<br />
– – – – –<br />
– – – – –<br />
59962 DUG-B2 1<br />
– – – – –<br />
– – – – –<br />
DUG190..<br />
30821A ..RM2 1 X – – – – – – – – – –<br />
DUG190/..<br />
59995 ..GES4-1 1 X<br />
D = 243 mm<br />
59964 DUG-B4 1<br />
DUG250-2..<br />
30337B ..GES4 1 X<br />
D = 282mm<br />
59964 DUG-B4 1<br />
DUG350-2..<br />
30316B ..GES4 1 X<br />
D = 383 mm<br />
59964 DUG-B4 1<br />
EÜK – Screed covered<br />
duct system<br />
DUG190/..<br />
59997 ..GESR4-1 1 X<br />
D = 243 mm<br />
DUG250-2..<br />
30337C ..R4 1 X<br />
D = 282mm<br />
DUG350-2..<br />
30316C ..R4 1 X<br />
D = 383 mm<br />
59963 DUG-B/R4 1<br />
59963 DUG-B/R4 1<br />
59963 DUG-B/R4 1<br />
– – – – –<br />
DUG250-2..<br />
30337D ..GES6 1 X<br />
D = 282mm<br />
DUG350-2..<br />
30316D ..GES6 1 X<br />
D = 383 mm<br />
– – – – –<br />
42311 DUG-B6 1<br />
42311 DUG-B6 1<br />
– – – – –<br />
– – – – –<br />
DUG350-2..<br />
30316H ..R7 1 X<br />
D=383 mm<br />
– – – – –<br />
– – – – –<br />
42955D DUG-B/R7 1<br />
– – – – –<br />
DUG250-2..<br />
30337E ..GES99 1 X<br />
DUG350-2..<br />
30316E ..GES9 1 X<br />
D = 383 mm<br />
– – – – –<br />
42955A DUG-B99 1<br />
42955A DUG-B9 1<br />
– – – – –<br />
– – – – –<br />
DUG350-2..<br />
30316G ..R9 1 X<br />
D=383 mm<br />
– – – – –<br />
– – – – –<br />
42955C DUG-B/R9 1<br />
45
EÜK – Screed-covered duct system<br />
Underfloor Service Box – UGD<br />
ACKERMANN - EÜK- VDE- ÖVE- - EÜK- VDE- ÖVE- KEMA- KEUR-<br />
Art. no. Code MOQ SI TI<br />
Underfloor box empty – UGD190 –<br />
For direct installation of a flush floor service unit GES<br />
installation unit or a ZES junction box insert.<br />
Levelling range: 70 -120 mm.<br />
<strong>for</strong> GES2 or ZES2<br />
<strong>for</strong> GES4(M) or ZES4<br />
<strong>for</strong> GESR4 or ZESR4<br />
30213A UGD190/2 1 X 24<br />
30,213B UGD190/4 1 X 24<br />
30213C UGD190R4 1 X 24<br />
Underfloor box empty – UGD250-2. –<br />
For direct installation of a flush floor service unit GES<br />
installation unit or a ZES junction box insert.<br />
Levelling range: 70 -120 mm.<br />
EÜK – screed covered<br />
duct system<br />
<strong>for</strong> GES4(M) or ZES4<br />
<strong>for</strong> GESR4 or ZESR4<br />
<strong>for</strong> GES6(M) or ZES6<br />
Underfloor box empty – UGD350-2. –<br />
For direct installation of a GRAF9 or a flush floor<br />
service unit GES installation unit or a ZES junction box<br />
insert.<br />
Levelling range: 70 -120 mm.<br />
30315B UGD250-2/4 1 X 24<br />
30315C UGD250-2R4 1 X 24<br />
30315D UGD250-2/6 1 X 24<br />
<strong>for</strong> GES4(M) or ZES4<br />
<strong>for</strong> GESR4 or ZESR4<br />
<strong>for</strong> GES6(M) or ZES6<br />
<strong>for</strong> GESR(A)7 or ZESR7<br />
<strong>for</strong> GES9(M) or ZES9<br />
<strong>for</strong> GRAF9, GESR(A)9 or ZESR9<br />
30313B UGD350-2/4 1 X 24<br />
30313C UGD350-2R4 1 X 24<br />
30313D UGD350-2/6 1 X 24<br />
30313H UGD350-2R7 1 X 24<br />
30313E UGD350-2/9 1 X 24<br />
30313G UGD350-2R9 1 X 24<br />
46
Art. no. Code MOQ SI TI<br />
Floor covering application frame - BAU -<br />
suitable <strong>for</strong> UZD190; as an application edge <strong>for</strong> firm<br />
floor coverings.<br />
3 or 5 mm, suitable <strong>for</strong> blanking cover DU118.<br />
Iron grey RAL 7011<br />
Grey beige RAL 1019<br />
30264A BAU190/5/7011 1 –<br />
Graphite RAL 9011<br />
30264E BAU190/5/1019 1 –<br />
30264F BAU190/5/9011 1 –<br />
Blanking cover - DU 118 -<br />
suitable <strong>for</strong> UZD190; suitable <strong>for</strong> floor covering<br />
application frames.<br />
Including NIROSTA cover fastening screws.<br />
30228 DU190/118 1 –<br />
Blanking cover - DU 120 -<br />
including NIROSTA cover fastening screws <strong>for</strong> frameless<br />
end covering of <strong>underfloor</strong> junction and branch boxes.<br />
s<br />
Suitable <strong>for</strong>:<br />
UZD190<br />
30260 DU190/120 1 X –<br />
UZD250-2<br />
30317A DU250-2 1 X –<br />
UZD350-2<br />
30317B DU350-2 1 X –<br />
Blanking cover – DUF –<br />
including RD rubber seal and V2A cover fixing screws<br />
<strong>for</strong> flush, moisture-protected sealing of <strong>underfloor</strong><br />
boxes.<br />
Material: 4 mm steel, pre-galvanised. 4 fixing screws<br />
included.<br />
Suitable <strong>for</strong>:<br />
UZD190<br />
30273A DUF190/120 1 –<br />
UZD250-2<br />
30318A DUF250-2 1 X –<br />
UZD350-2<br />
30318B DUF350-2 1 X –<br />
Mounting lid - DU 190/119 -<br />
<strong>for</strong> frameless covering in dry rooms<br />
with dry-cleaned floors <strong>for</strong> floor covering<br />
application frames, <strong>for</strong> the installation of a Telitank.<br />
30279A DU190/119 1 –<br />
EÜK – Screed-covered duct system<br />
Floor covering application frame<br />
Installation cover<br />
p<br />
q<br />
p<br />
100<br />
j<br />
s<br />
<br />
q<br />
D<br />
100<br />
D<br />
100<br />
s<br />
s<br />
Mounting lid - DUF-DAT -<br />
<strong>for</strong> frameless covering in dry rooms with wet-cleaned<br />
floors (moisture protection according to DIN VDE<br />
0634), <strong>for</strong> the installation of a Telitank.<br />
Suitable <strong>for</strong>:<br />
UZD190<br />
UZD250-2<br />
UZD350-2<br />
Blanking plate - DATF - (individual part)<br />
<strong>for</strong> later closing off of an installation opening <strong>for</strong> the<br />
Telitank.<br />
With rubber sealing plate (moisture protection according<br />
to DIN VDE 0634), fastening screws.<br />
30271A DUF190/123E 1 –<br />
30320A DUF250-2DAT 1 –<br />
30320B DUF350-2DAT 1 –<br />
30272A DATF 1 –<br />
47<br />
EÜK – Screed covered<br />
duct system
Accessories <strong>for</strong> dry rooms<br />
with dry-cleaned floors<br />
Square cassette solutions<br />
Load capacity and moisture protection according to DIN VDE 0634.<br />
Technical data<br />
Material<br />
- Cassette frame: V2A or brass, 2mm<br />
- Cassette: V2A or brass, 2mm, with 4 mm steel plate<br />
- Cord outlet: Polyamide or V2A or brass<br />
g<br />
Cassette frame – RKS –<br />
with edge cord outlet <strong>for</strong> the fitting of installation<br />
devices in dry-cleaned floorings.<br />
Material: V2A<br />
Height H = 15 mm<br />
Height H = 20 mm<br />
Height H = 25 mm<br />
Load capacity: Screed-flush sections of the duct system and<br />
cassettes correspond to DIN VDE 0634 Part 1<br />
and Part 2.<br />
Moisture protection:<br />
RKS cassettes (with cord outlet) <strong>for</strong> dry-cleaned floors<br />
h<br />
f<br />
Material: Brass<br />
Height H = 15 mm<br />
Height H = 20 mm<br />
Height H = 25 mm<br />
Application<br />
Office and administrative buildings, heavy-duty applications only with<br />
additional extensions.<br />
For technical data, see Page 28.<br />
EÜK – Screed covered<br />
duct system<br />
Cord outlet - SAK -<br />
<strong>for</strong> installation in the cord outlet cassette.<br />
Material: Polyamide<br />
Iron grey, RAL 7011<br />
Sepia brown, RAL 8014<br />
Grey beige, RAL 1019<br />
Graphite black, RAL 9011<br />
Cord outlet - SAK -<br />
<strong>for</strong> installation in the cord outlet cassette.<br />
Material: Metal<br />
V2A<br />
Brass<br />
Installation kit – MS.190 –<br />
<strong>for</strong> fitting of 4 individual installation devices in the<br />
<strong>underfloor</strong> junction and branch boxes.<br />
With 2 mounting boxes GB 2 and all the parts<br />
required <strong>for</strong> fitting.<br />
Installation kit <strong>for</strong> installation of<br />
devices under cassettes<br />
Instructions <strong>for</strong> MS mounting sets.<br />
Note: no device installation possible to a height of<br />
115 mm under RKF cassette (top edge of raw floor<br />
to top edge of finished floor E).<br />
Installation kit – MS. –<br />
<strong>for</strong> fitting of 9 individual installation devices in the<br />
<strong>underfloor</strong> junction and branch box.<br />
With 3 mounting boxes GB 3 and all the parts<br />
required <strong>for</strong> fitting.<br />
Note: minimum fitting height 75 mm.<br />
E<br />
Ladder extension – GES/RV<br />
2-part component that can be slotted onto the<br />
MSRK installation kit.<br />
Note: Component is required if the middle<br />
mounting box is to be used under cassette RKF.<br />
Supplied in packs of 2.<br />
E = installation height required<br />
Cassette version UZD190 UZD250-2/350-2<br />
- RKS = 85 mm = 90 mm<br />
* For installation heights between 85 and 115 mm, the middle mounting<br />
box cannot be used, and <strong>for</strong> installation heights of 115 to 125 mm,<br />
the middle mounting box can only be fitted with power sockets.<br />
Mounting tray – MT2/.BS.RKS –<br />
<strong>for</strong> installation of BS devices under frame cassettes<br />
<strong>for</strong> cord outlet in dry cleaned floors.<br />
2-compartment <strong>for</strong> UZD190<br />
3-compartment <strong>for</strong> UZD250-2<br />
3 compartment <strong>for</strong> UZD350-2<br />
4-compartment <strong>for</strong> UZD350-2<br />
48
Nominal size 190 mm <strong>for</strong> UZD190-2<br />
Art. no. Code MOQ TI<br />
Nominal size 250 mm <strong>for</strong> UZD250-2<br />
Art. no. Code MOQ TI<br />
Nominal size 350 mm <strong>for</strong> UZD350-2<br />
Art. no. Code MOQ TI<br />
30060B RKS/V1/15 1 28<br />
30060C RKS/V1/20 1 28<br />
30060B RKS/V1/25 1 28<br />
g = 244 mm<br />
f = 250 mm<br />
30087B RKS2V2/15 1 28<br />
30087C RKS2V2/20 1 28<br />
30087D RKS2V2/25 1 28<br />
g = 282mm<br />
f = 288 mm<br />
30066B RKS/V3/15 1 28<br />
30066C RKS/V3/20 1 28<br />
30066D RKS/V3/25 1 28<br />
g = 383 mm<br />
f = 388 mm<br />
30061B RKS/M1/15 1 28<br />
30061C RKS/M1/20 1 28<br />
30061D RKS/M1/25 1 28<br />
g = 244 mm<br />
f = 250 mm<br />
30088B RKS2M2/15 1 28<br />
30088C RKS2M2/20 1 28<br />
30088D RKS2M2/25 1 28<br />
g = 282mm<br />
f = 288 mm<br />
30067B RKS/M3/15 1 28<br />
30067C RKS/M3/20 1 28<br />
30067D RKS/M3/25 1 28<br />
g = 383 mm<br />
f = 388 mm<br />
30373AA SAK7011 1 X<br />
30373AC SAK8014 1 X<br />
30373AE SAK1019 1 X<br />
30373AF SAK9011 1 X<br />
30373AA SAK7011 1 28<br />
30373AC SAK8014 1 28<br />
30373AE SAK1019 1 28<br />
30373AF SAK9011 1 28<br />
30373AA SAK7011 1 28<br />
30373AC SAK8014 1 28<br />
30373AE SAK1019 1 28<br />
30373AF SAK9011 1 28<br />
EÜK – Screed covered<br />
duct system<br />
30373BA SAKV2A 1 X<br />
30373BB SAKMS 1 X<br />
30373BA SAKV2A 1<br />
30373BB SAKMS 1<br />
30373BA SAKV2A 1 X<br />
30373BB SAKMS 1<br />
30882G MS190/2GB2 1 X – – – – – – – –<br />
– – –<br />
MS250-2/..<br />
30882H ..3GB3 1 X<br />
MS350-2/..<br />
30882J ..3GB3 1 X<br />
30768A1 GES/RV 1 X 30768A1 GES/RV 1 X 30768A1 GES/RV 1 X<br />
MT2/190..<br />
30883 kA ..BS2RKS 1 MT2/250-2..<br />
30883 LA ..BS3RKS 1 MT2/350-2..<br />
30388 MA ..BS3RKS 1<br />
30388 RA ..BS4RKS 1<br />
49
Accessories <strong>for</strong> dry rooms<br />
with wet-cleaned floors<br />
Square cassette solutions<br />
Load capacity and moisture protection according to DIN VDE 0634.<br />
Note<br />
Floor coverings with rough surfaces required additional equipment in<br />
the cassettes such as threaded sleeves (on request).<br />
Flooring insert cassette – BEK/F –<br />
including rubber seal. For moisture-protected final<br />
sealing of <strong>underfloor</strong> junction and branch boxes.<br />
Material: V2A, 1mm thick.<br />
Technical data<br />
Material<br />
- Cassette frame: V2A or brass, 2 mm<br />
– Cassette: V2A or brass, 1.5 mm, with 4 mm steel plate<br />
- Tube: Polyamide with metal cover V2A or MS<br />
Load capacity: Screed-flush sections of the duct system and<br />
cassettes correspond to DIN VDE 0634 Part 1<br />
and Part 2.<br />
L<br />
L<br />
H=3 mm<br />
H=4 mm<br />
H=5 mm<br />
Cassette frame – RK –<br />
<strong>for</strong> junction boxes, with cassette <strong>for</strong> wood, ceramic<br />
and stone floorings, <strong>for</strong> smooth floorings only.<br />
H=Height cassette frame.<br />
Material: V2A.<br />
Moisture protection:<br />
RK, RKF and BEK/F cassettes <strong>for</strong> dry<br />
and wet-cleaned floors.<br />
Application<br />
Office and administrative buildings, heavy-duty applications only<br />
with additional extensions.<br />
H<br />
H=10 mm<br />
H=15 mm<br />
H=20 mm<br />
H=25 mm<br />
EÜK – Screed covered<br />
duct system<br />
For technical data, see Page 28.<br />
H<br />
L<br />
Cassette frame – RKF –<br />
with central tube cord outlet <strong>for</strong> the installation of<br />
installation devices in wet-cleaned floorings.<br />
H=Height cassette frame.<br />
Material: V2A.<br />
H=10 mm<br />
H=15 mm<br />
H=20 mm<br />
H=25 mm<br />
Tube - TUK -<br />
<strong>for</strong> use and cassettes RKF with BS installation.<br />
Tube with handle bar and cover from V2A.<br />
Tube colour<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
Sepia brown, RAL 8014<br />
Grey beige, RAL 1019<br />
Mounting set <strong>for</strong> installation of devices<br />
under cassettes<br />
Instructions <strong>for</strong> MS mounting sets.<br />
E<br />
Tube - TUK -<br />
<strong>for</strong> installation in the RKF cassette.<br />
– Material: Polyamide.<br />
Tube with V2A handle bar and cover,<br />
Tube in Iron grey, RAL 7011<br />
Tube in Graphite black, RAL 9011<br />
Tube with MS handle bar and cover,<br />
Tube in Sepia brown, RAL 8014<br />
Tube in Grey beige, RAL 1019<br />
– Material: Aluminium natural anodised<br />
Installation kit – MS.190 –<br />
<strong>for</strong> fitting of 4 or 9 individual installation devices in the<br />
<strong>underfloor</strong> junction and branch boxes.<br />
With mounting boxes and all parts required <strong>for</strong> fitting.<br />
With 2 x mounting box GB2<br />
With 3 x mounting box GB3<br />
Note<br />
<strong>for</strong> the minimum installation height, see the table at<br />
the bottom left. Device installation in UZD190 under<br />
RKF only possible with ladder extension.<br />
(see Pages 48, 49).<br />
Required installation heights E<br />
Cassette version UZD190 UZD250-2/350-2<br />
RKF E = 125 mm E = 125 mm *<br />
* For installation heights between 85 and 115 mm, the middle mounting<br />
box cannot be<br />
used, and <strong>for</strong> installation heights of 115 to 125 mm, the middle<br />
mounting box can only be fitted with sockets.<br />
Mounting tray – MT2/.BS.RKF –<br />
<strong>for</strong> installation of BS devices under frame cassettes<br />
<strong>for</strong> tubes in wet-cleaned floors.<br />
2 comp. <strong>for</strong> UZD 190<br />
3 comp. <strong>for</strong> UZD 250-2<br />
3 comp. <strong>for</strong> UZD 350-2<br />
4 comp. <strong>for</strong> UZD 350-2<br />
50
Nominal size 190 mm <strong>for</strong> UZD190-2<br />
Art. no. Code MOQ SI TI<br />
Nominal 250 mm <strong>for</strong> UZD250-2<br />
Art. no. Code MOQ SI TI<br />
Nominal size 350 mm <strong>for</strong> UZD350-2<br />
Art. no. Code MOQ SI TI<br />
– – – – –<br />
– – – – –<br />
– – – – –<br />
BEK/..<br />
30360B ..F250-2/3 1<br />
30360C ..F250-2/4 1<br />
30360D ..F250-2/5 1<br />
L = 282mm<br />
BEK/..<br />
30352B ..F350-2/3 1<br />
30352C ..F350-2/4 1<br />
30352D ..F350-2/5 1<br />
L = 383 mm<br />
30072A RK/V1/10 1<br />
30072B RK/V1/15 1<br />
30072C RK/V1/20 1<br />
30072D RK/V1/25 1<br />
L = 244 mm<br />
30081A RK/V2/10 1<br />
30081B RK/V2/15 1<br />
30081C RK/V2/20 1<br />
30081D RK/V2/25 1<br />
L = 282mm<br />
30078A RK/V3/10 1<br />
30078B RK/V3/15 1<br />
30078C RK/V3/20 1<br />
30078D RK/V3/25 1<br />
L = 383 mm<br />
30090A RKF2V1/10 1<br />
30090B RKF2V1/15 1<br />
30090C RKF2V1/20 1<br />
30090D RKF2V1/25 1<br />
L = 244 mm<br />
30084A RKF2V2/10 1<br />
30084B RKF2V2/15 1<br />
30084C RKF2V2/20 1<br />
30084D RKF2V2/25 1<br />
L = 282mm<br />
30093A RKF2V3/10 1<br />
30093B RKF2V3/15 1<br />
30093C RKF2V3/20 1<br />
30093D RKF2V3/25 1<br />
L = 383 mm<br />
EÜK – Screed covered<br />
duct system<br />
TUK..<br />
30391AC ..VBS7011 1<br />
30391FC ..VBS9011 1<br />
30391CC ..VBS8014 1<br />
30391EC ..VBS1019 1<br />
TUK..<br />
30391AC ..VBS7011 1<br />
30391FC ..VBS9011 1<br />
30391CC ..VBS8014 1<br />
30391EC ..VBS1019 1<br />
TUK..<br />
30391AC ..VBS7011 1<br />
30391FC ..VBS9011 1<br />
30391CC ..VBS8014 1<br />
30391EC ..VBS1019 1<br />
30374AA TUKV7011 1 X<br />
30374AF TUKV9011 1 X<br />
30374AA TUKV7011 1 X<br />
30374AF TUKV9011 1 X<br />
30374AA TUKV7011 1 X<br />
30374AF TUKV9011 1 X<br />
30374BC TUKM8014 1 X<br />
30374BE TUKM1019 1 X<br />
30117A1 TUKA 1 X<br />
30374BC TUKM8014 1 X<br />
30374BE TUKM1019 1 X<br />
30117A1 TUKA 1 X<br />
30374BC TUKM8014 1 X<br />
30374BE TUKM1019 1 X<br />
30117A1 TUKA 1 X<br />
MS190/..<br />
30882G ..2GB2 1 X MS250-2/..<br />
30882H ..3GB3 – – –<br />
MS350-2/..<br />
30882J ..3GB3 – – –<br />
MT2/190..<br />
30883NA ..BS2RKF – – – MT2/250-2..<br />
30883PA ..BS3RKF<br />
30883QA<br />
30883SA<br />
MT2/350-2..<br />
..BS3RKF<br />
..BS4RKF<br />
51
Accessories <strong>for</strong> dry rooms<br />
with dry or wet-cleaned floors<br />
Heavy-duty cassettes, square design<br />
Square heavy-duty cassette with Tube<br />
EÜK – screed covered<br />
duct system<br />
Underfloor junction and branch box UZD<br />
with heavy-duty support<br />
52
Accessories <strong>for</strong> dry rooms<br />
with dry or wet-cleaned floors<br />
Heavy-duty cassettes, square design<br />
Art. no. Code MOQ TI<br />
Cassette frame – RKSL –<br />
<strong>for</strong> inspection openings, with cassette <strong>for</strong> wood, ceramic and<br />
stone coverings, only <strong>for</strong> smooth floor coverings.<br />
H=Height of the cassette frame.<br />
Material: V2A<br />
H<br />
L<br />
Suitable <strong>for</strong> UZD250-2:<br />
Load class 1<br />
Load class 2<br />
Suitable <strong>for</strong> UZD350-2:<br />
Load class 1<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
30120C RK/SL1V2/20 1 36<br />
30120D RK/SL1V2/25 1 36<br />
30120E RK/SL1V2/30 1 36<br />
30120G RK/SL1V2/40 1 36<br />
30124C RK/SL2V2/20 1 36<br />
30124D RK/SL2V2/25 1 36<br />
30124E RK/SL2V2/30 1 36<br />
30124G RK/SL2V2/40 1 36<br />
30121C RK/SL1V3/20 1 36<br />
30121D RK/SL1V3/25 1 36<br />
30121E RK/SL1V3/30 1 36<br />
30121G RK/SL1V3/40 1 36<br />
EÜK – screed covered<br />
duct system<br />
Load class 2<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
30125C RK/SL2V3/20 1 36<br />
30125D RK/SL2V3/25 1 36<br />
30125E RK/SL2V3/30 1 36<br />
30125G RK/SL2V3/40 1 36<br />
Cassette frame – RKFSL –<br />
<strong>for</strong> installation of units in<br />
wet-cleaned floors.<br />
H=Height of the cassette frame.<br />
Material: V2A<br />
Note: Order the Tube separately (see Page 54)<br />
L<br />
Suitable <strong>for</strong> UZD250-2:<br />
Load class 1<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
30122C RKF/SL1V2/20 1 36<br />
30122D RKF/SL1V2/25 1 36<br />
30122E RKF/SL1V2/30 1 36<br />
30122G RKF/SL1V2/40 1 36<br />
H<br />
Load class 2<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
30126C RKF/SL2V2/20 1 36<br />
30126D RKF/SL2V2/25 1 36<br />
30126E RKF/SL2V2/30 1 36<br />
30126G RKF/SL2V2/40 1 36<br />
Suitable <strong>for</strong> UZD350-2:<br />
Load class 1<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
30123C RKF/SL1V3/20 1 36<br />
30123D RKF/SL1V3/25 1 36<br />
30123E RKF/SL1V3/30 1 36<br />
30123G RKF/SL1V3/40 1 36<br />
Load class 2<br />
H = 20 mm<br />
H=25 mm<br />
H=30 mm<br />
H=40 mm<br />
30127C RKF/SL2V3/20 1 36<br />
30127D RKF/SL2V3/25 1 36<br />
30127E RKF/SL2V3/30 1 36<br />
30127G RKF/SL2V3/40 1 36<br />
heavy-duty support - DSSL -<br />
to support the corner areas of<br />
UZD/ARU and square cassettes.<br />
Levelling screw with locknut.<br />
Height ranges in mm: 70 + 25<br />
90 + 40<br />
120 + 40<br />
150 + 40<br />
Mounting set - MS -<br />
<strong>for</strong> device installation beneath the heavy-duty cassettes.<br />
With fastening rails and mounting boxes.<br />
33016A DSSL70/95 4 X<br />
33016B DSSL90/130 4 X<br />
33016C DSSL120/160 4 X<br />
33016D DSSL150/190 4 X<br />
Note: Mounting trays <strong>for</strong> BS installations<br />
see Page 97<br />
3 x GB2<br />
3 x GB3<br />
30882B MS3GB2 1 X<br />
30882D MS3GB3 1 X<br />
53
Accessories <strong>for</strong> dry rooms<br />
with dry or wet-cleaned floors<br />
Heavy-duty cassettes, round design<br />
Levelling unit<br />
Adjustable<br />
Cassette <strong>for</strong> floor covering thickness<br />
20 mm 25 mm<br />
Included in delivery max. 155 mm max. 159 mm<br />
RKNEV110 (30116BV) 145 + 40 mm 150 + 40 mm<br />
RKNEV150 (30116CV) 185 + 40 mm 190 + 40 mm<br />
Art. no. Code MOQ SI TI<br />
Cassette frame – RKRSL –<br />
<strong>for</strong> inspection openings. With cassette <strong>for</strong> wood, ceramic and<br />
stone coverings, only <strong>for</strong> smooth floor coverings.<br />
Load class 2.<br />
H=Height of the floor covering recess.<br />
Material: V2A<br />
Nominal size R4<br />
Installation diameter in mm: ø 214.<br />
H=20 mm<br />
H=25 mm<br />
30128B RKR4SL2V2/20 1<br />
30128C RKR4SL2V2/25 1<br />
EÜK – Screed covered<br />
duct system<br />
Nominal size R7<br />
Installation diameter in mm: ø 275.<br />
Nominal size R9<br />
Installation diameter in mm: ø 305.<br />
H=20 mm<br />
H=25 mm<br />
H=20 mm<br />
H=25 mm<br />
30129B RKR7SL2V2/20 1<br />
30129C RKR7SL2V2/25 1<br />
30130B RKR9SL2V2/20 1<br />
30130C RKR9SL2V2/25 1<br />
Note: Mounting trays <strong>for</strong> BS installations see Page 97<br />
Cassette frame – RKFRSL –<br />
<strong>for</strong> installation of units in wet-cleaned<br />
floors.<br />
Please order the Tube separately.<br />
H=Height of the floor covering recess..<br />
Material: V2A<br />
Nominal size R4<br />
Installation diameter in mm: ø 214.<br />
H=20 mm<br />
H=25 mm<br />
30131B RKFR4SL2V2/20 1<br />
30131C RKFR4SL2V2/25 1<br />
Nominal size R7<br />
Installation diameter in mm: ø 275.<br />
H=20 mm<br />
H=25 mm<br />
30132B RKFR7SL2V2/20 1<br />
30132C RKFR7SL2V2/25 1<br />
Nominal size R9<br />
Installation diameter in mm: ø 305.<br />
H=20 mm<br />
H=25 mm<br />
30133B RKFR9SL2V2/20 1<br />
30133C RKFR9SL2V2/25 1<br />
Note: Mounting trays <strong>for</strong> BS installations see Page 97<br />
Tube - TUK -<br />
<strong>for</strong> installation in RKFRSL and RKFSL cassettes<br />
Tube with V2A handle bar and top cover.<br />
Material: Polyamide.<br />
Material: Aluminium<br />
Iron grey RAL 7011<br />
Graphite black RAL 9011<br />
natural anodised<br />
30374AA TUKV7011 1 X<br />
30374AF TUKV9011 1 X<br />
30117A1 TUKA 1 X<br />
heavy-duty support - DSSL -<br />
to support the corner areas of<br />
UZD/ARU and square cassettes.<br />
Levelling screw with locknut.<br />
Height ranges in mm: 70 + 25<br />
90 + 40<br />
120 + 40<br />
150 + 40<br />
33016A DSSL70/95 4 X –<br />
33016B DSSL90/130 4 X –<br />
33016C DSSL120/160 4 X –<br />
33016D DSSL150/190 4 X –<br />
54
Accessories <strong>for</strong> dry rooms<br />
with dry or wet-cleaned floors<br />
Accessories <strong>for</strong> round heavy-duty cassettes<br />
Mounting cover, heavy-duty support<br />
Art. no. Code MOQ SI TI<br />
Mounting lid – DUG.R.SL –<br />
<strong>for</strong> installation of a round heavy-duty cassette in<br />
UZD250-2 and UZD350-2 <strong>for</strong> high traffic loads.<br />
With four adjustable supports to accept the live load.<br />
Levelling screws with locknut.<br />
Mounting lid- DUG250-2R4SL -<br />
suitable <strong>for</strong> installation of a round heavy-duty cassette<br />
R4 in UZD250-2.<br />
D=ø 215 mm.<br />
External dimensions in mm: 282 x 282.<br />
Levelling area in mm: 75 + 35<br />
100 + 40<br />
130 + 40<br />
Mounting lid- DUG350-2R4SL -<br />
suitable <strong>for</strong> installation of a round heavy-duty cassette<br />
R4 in UZD350-2.<br />
D=ø 215 mm.<br />
External dimensions in mm: 383 x 383.<br />
Levelling area in mm: 75 + 35<br />
100 + 40<br />
130 + 40<br />
DUG250-2..<br />
30340AA ..R4SL75/110 1 –<br />
30340AB ..R4SL100/140 1 –<br />
30340AC ..R4SL130/170 1 –<br />
DUG350-2..<br />
30349AA ..R4SL75/110 1 –<br />
30349AB ..R4SL100/140 1 –<br />
30349AC ..R4SL130/170 1 –<br />
EÜK – Screed covered<br />
duct system<br />
Mounting lid - DUG350-2R7SL -<br />
suitable <strong>for</strong> installation of a round heavy-duty cassette<br />
R7 in UZD350-2.<br />
D=ø 275 mm.<br />
External dimensions in mm: 383 x 383.<br />
Levelling area in mm: 75 + 35<br />
100 + 40<br />
130 + 40<br />
Mounting lid- DUG350-2R9SL -<br />
suitable <strong>for</strong> installation of a round heavy-duty cassette<br />
R9 in UZD350-2.<br />
D=ø 305 mm.<br />
External dimensions in mm: 383 x 383.<br />
Levelling area in mm: 75 + 35<br />
100 + 40<br />
130 + 40<br />
heavy-duty support - DSSL -<br />
to support the corner areas of<br />
UZD/ARU and square cassettes.<br />
Levelling screw with locknut.<br />
Height ranges in mm: 70+25<br />
90+40<br />
120+40<br />
150+40<br />
DUG350-2..<br />
30367AA ..R7SL75/110 1 –<br />
30367AB ..R7SL100/140 1 –<br />
30367AC ..R7SL130/170 1 –<br />
DUG350-2..<br />
30341AA ..R9SL75/110 1 –<br />
30341AB ..R9SL100/140 1 –<br />
30341AC ..R9SL130/170 1 –<br />
33016A DSSL70/95 4 X –<br />
33016B DSSL90/130 4 X –<br />
33016C DSSL120/160 4 X –<br />
33016D DSSL150/190 4 X –<br />
55
EÜK – Screed covered<br />
duct system<br />
EÜK – Screed-covered duct system<br />
Underfloor outlet box UDL<br />
Single outlet US80<br />
Underfloor outlet box – UDL –<br />
<strong>for</strong> conduit installation M20 oder Pg16.<br />
Material: pre-galvanised metal sheet box sealed with<br />
assembly protection cover.<br />
– UDL2-80 –<br />
For fitting of a pedestal service outlet unit which<br />
projects above the floor (Telitank) or a SH or SHF<br />
variable height installation unit.<br />
For screed heights of 70 to 85 mm.<br />
Note:<br />
Assembly protection cover to be replaced after<br />
screed work.<br />
Single outlet – US80 –<br />
suitable <strong>for</strong> fitting of an installation device in dry areas or<br />
fitting a Telitank <strong>for</strong> subsequent drilling of channels.<br />
Screed heights above the duct: 32 – 45 mm.<br />
Material: die-cast zinc.<br />
Adjustment ring – AR –<br />
to increase the height of the <strong>underfloor</strong> outlet box<br />
UDL2-80 and the single outlet US80 by 24 mm.<br />
Material: die-cast zinc.<br />
Blanking plate – DBS –<br />
can be used as assembly protection cover <strong>for</strong> single<br />
outlet US80.<br />
Material: 2mm sheet steel, pre-galvanised.<br />
Blank cover – BAB –<br />
can be screwed into US80<br />
Material: polyamide, matt surface.<br />
External dimension: ø 100 mm.<br />
<br />
Art. no. Code MOQ SI TI<br />
<br />
30220C UDL2-80/70 1 X –<br />
30277A US80/32 1 X –<br />
55528 AR80/24 1 –<br />
58186 DBS80 1 –<br />
Colour: Iron grey RAL 7011<br />
Grey beige RAL 1019<br />
Graphite black RAL 9011<br />
30027A BAB80/7011 1 X –<br />
30027E BAB80/1019 1 –<br />
30027F BAB80/9011 1 X –<br />
Spacer ring - US80D - (individual part)<br />
<strong>for</strong> level compensation (tight fitting to the floor covering)<br />
between the Telitank base plate and the duct outlet<br />
mounting ring.<br />
42720 US80D 1 –<br />
Earth conductor clamp – 8AWR –<br />
<strong>for</strong> use in <strong>underfloor</strong> junction and branch boxes UZD<br />
and <strong>underfloor</strong> empty box UGD.<br />
Material: sheet steel, galvanised, yellow passivated.<br />
Terminal range: 2 x 1.5 – 4 mm.<br />
35083CV 8AWR 10 X –<br />
56
EÜK – Screed covered<br />
duct system<br />
EÜK – Screed-covered duct system<br />
Underfloor outlet box UDL<br />
Single outlet US80<br />
Underfloor outlet box – UDL –<br />
<strong>for</strong> conduit installation M20 oder Pg16.<br />
Material: pre-galvanised metal sheet box sealed with<br />
assembly protection cover.<br />
– UDL2-80 –<br />
For fitting of a pedestal service outlet unit which<br />
projects above the floor (Telitank) or a SH or SHF<br />
variable height installation unit.<br />
For screed heights of 70 to 85 mm.<br />
Note:<br />
Assembly protection cover to be replaced after<br />
screed work.<br />
Single outlet – US80 –<br />
suitable <strong>for</strong> fitting of an installation device in dry areas or<br />
fitting a Telitank <strong>for</strong> subsequent drilling of channels.<br />
Screed heights above the duct: 32 – 45 mm.<br />
Material: die-cast zinc.<br />
Adjustment ring – AR –<br />
to increase the height of the <strong>underfloor</strong> outlet box<br />
UDL2-80 and the single outlet US80 by 24 mm.<br />
Material: die-cast zinc.<br />
Blanking plate – DBS –<br />
can be used as assembly protection cover <strong>for</strong> single<br />
outlet US80.<br />
Material: 2mm sheet steel, pre-galvanised.<br />
Blank cover – BAB –<br />
can be screwed into US80<br />
Material: polyamide, matt surface.<br />
External dimension: ø 100 mm.<br />
<br />
Art. no. Code MOQ SI TI<br />
<br />
30220C UDL2-80/70 1 X –<br />
30277A US80/32 1 X –<br />
55528 AR80/24 1 –<br />
58186 DBS80 1 –<br />
Colour: Iron grey RAL 7011<br />
Grey beige RAL 1019<br />
Graphite black RAL 9011<br />
30027A BAB80/7011 1 X –<br />
30027E BAB80/1019 1 –<br />
30027F BAB80/9011 1 X –<br />
Spacer ring - US80D - (individual part)<br />
<strong>for</strong> level compensation (tight fitting to the floor covering)<br />
between the Telitank base plate and the duct outlet<br />
mounting ring.<br />
42720 US80D 1 –<br />
Earth conductor clamp – 8AWR –<br />
<strong>for</strong> use in <strong>underfloor</strong> junction and branch boxes UZD<br />
and <strong>underfloor</strong> empty box UGD.<br />
Material: sheet steel, galvanised, yellow passivated.<br />
Terminal range: 2 x 1.5 – 4 mm.<br />
35083CV 8AWR 10 X –<br />
56
The flushfloor trunking system - OKA/T - is used <strong>for</strong> conductor routing and the installation of electrical resources in<br />
the <strong>underfloor</strong> area. The trunking system can be opened along its entire length and is thus particularly suitable <strong>for</strong><br />
regular changes to laid conductors in dry-cleaned floors.<br />
The primary advantages of the system include: no welds, snap-in partitions, no pre-fabricated junctions required,<br />
lid fixing at any point along the trunking route and floor service outlets at any point.<br />
These advantages reduce installation times and costs.<br />
58
OKA/T - Open flushfloor trunking system<br />
Trunking systems<br />
and accessories from Page 60 - 69<br />
59
Open, flushfloor<br />
trunking system<br />
– OKA/T –<br />
The Ackermann open, flushfloor trunking<br />
system, is accessible at all<br />
points in its route. This enables cabling<br />
configurations to be changed<br />
quickly and cost-effectively at any<br />
time.<br />
Trunking sections are fixed to flat surfaces<br />
(ribbon screed) via slab brakkets.<br />
In case of uneven surfaces fixing<br />
angles are used to adjust the<br />
trunking to screed level. Cover plates<br />
are fully interchangeable.<br />
d<br />
i<br />
k<br />
h<br />
a<br />
l<br />
n<br />
m<br />
b<br />
c<br />
f<br />
g<br />
e<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Dimensions<br />
Legend:<br />
a OKA trunking unit<br />
b trunking base<br />
c cover-plate <strong>for</strong> installation of a GES6 service outlet<br />
d slab bracket<br />
e levelling bracket (optional)<br />
f screed anchor (optional)<br />
g<br />
h<br />
i<br />
k<br />
l<br />
m<br />
n<br />
aluminium side profile<br />
connection angle<br />
divider<br />
cross over<br />
rough concrete (with ribbon screed)<br />
screed structure<br />
Floor covering<br />
N +25<br />
H<br />
N<br />
N= trunking base width (300 or 350 mm)<br />
H=trunking height (60, 65 or 80 mm)<br />
60
Tee-section<br />
90º section<br />
OKA/T - Open flushfloor<br />
trunking system<br />
cross section<br />
61
Open flush floor trunking<br />
system – OKA/T –<br />
2 compartments<br />
flush floor trunking<br />
with blind covers<br />
Trunking<br />
• Material<br />
– Side profiles: aluminium.<br />
– Trunking base: galvanised steel, 1mm.<br />
– Trunking cover plate: galvanised steel, 3 mm.<br />
• Dimensions<br />
– Size = trunking base width (300 or 350 mm).<br />
– Other dimensions on request.<br />
• Delivery<br />
– Trunking set delivered in single parts.<br />
– Single cover plates on request.<br />
• Contents<br />
– Trunking set consists of:<br />
- trunking base<br />
- side profiles incl. floor guide profile<br />
- cover plates<br />
- coupling bars.<br />
- 6 slab brackets<br />
– 90° angle set consists of:<br />
- end cap<br />
- connecting set<br />
- slab bracket.<br />
flush floor trunking<br />
<strong>for</strong> GES4OK<br />
end cap<br />
90° angle set<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Partitions, crossovers etc. to be<br />
ordered separately.<br />
MOQ = 1 piece<br />
Riser bend<br />
Flush floor trunking set<br />
with blind covers.<br />
(delivery in single parts.)<br />
H = 60 mm<br />
H = 65 mm<br />
Size 300 Size 350<br />
Art. no. Code Art. no. Code<br />
OKA/TS2300..<br />
OKA/TS2350..<br />
33273A ..60D3 33274A ..60D3<br />
33273B ..65D3 33274B ..65D3<br />
Flush floor trunking set<br />
to accept 3 times GES4OK<br />
service outlets<br />
(delivery in single parts.)<br />
End cap<br />
H = 60 mm<br />
H = 65 mm<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/TS2300..<br />
OKA/TS2350..<br />
33265A ..60DG4 33266A ..60DG4<br />
33265B ..65DG4 33266B ..65DG4<br />
OKA/E300..<br />
OKA/E350..<br />
33232AA ..60D3 33232BA ..60D3<br />
33232AB ..65D3 33232BB ..65D3<br />
90° angle set<br />
<strong>for</strong> left or right angle<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/B300..<br />
OKA/B350..<br />
33233AA ..60D3 33233BA ..60D3<br />
33233AB ..65D3 33233BB ..65D3<br />
Riser bend<br />
2-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/RB2/300..<br />
OKA/RB2/350..<br />
33267A ..60 33268A ..60<br />
33267B .0.65 33268B ..65<br />
62
flush floor trunking<br />
Open flush floor trunking<br />
system – OKA/T –<br />
3 compartments<br />
Trunking<br />
flush floor trunking<br />
<strong>for</strong> GES9OK<br />
end cap<br />
90° angle set<br />
• Material<br />
– Side profiles: aluminium.<br />
– Trunking base: galvanised steel, 1mm.<br />
– Trunking cover plate: galvanised steel, 3 mm.<br />
• Dimensions<br />
– Size = trunking base width (300, 350 or 400 mm).<br />
– Other dimensions on request.<br />
• Delivery<br />
– Trunking set delivered in single parts.<br />
– Single cover plates on request.<br />
• Contents<br />
– Trunking set consists of:<br />
- trunking base<br />
- side profiles incl. floor guide profile<br />
- cover plates<br />
- coupling bars.<br />
- 6 slab brackets<br />
– 90° angle set consists of:<br />
- end cap<br />
- connecting set<br />
- slab bracket.<br />
Riser bend<br />
Partitions, crossovers etc.<br />
to be ordered separately.<br />
MOQ = 1 piece<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Flush floor trunking set<br />
with blind covers.<br />
(delivery in single parts.)<br />
H = 60 mm<br />
H = 65 mm<br />
Size 300 Size 350 Size 400<br />
Art. no. Code Art. no. Code Art. no. code<br />
OKA/TS3/300.. OKA/TS3/350.. OKA/TS3/400..<br />
33220A ..60D3 33221A ..60D3 33222A ..60D3<br />
33220B ..65D3 33221B ..65D3 33222B ..65D3<br />
Flush floor trunking set<br />
to accept 3 times GES9OK<br />
service outlets<br />
(delivery in single parts.)<br />
End cap<br />
H = 60 mm<br />
H = 65 mm<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/TS3/300.. OKA/TS3/350.. OKA/TS3/400..<br />
33254A ..60DG9 33255A ..60DG9 33256A ..60DG9<br />
33254B ..65DG9 33255B ..65DG9 33256B ..65DG9<br />
OKA/E300.. OKA/E350.. OKA/E400..<br />
33232AA ..60D3 33232BA ..60D3 33232CA ..60D3<br />
33232AB ..65D3 33232BB ..65D3 33232CB ..65D3<br />
90° angle set<br />
<strong>for</strong> left or right angle.<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/B300.. OKA/B350.. OKA/B400..<br />
33233AA ..60D3 33233BA ..60D3 33233CA ..60D3<br />
33233AB ..65D3 33233BB ..65D3 33233CB ..65D3<br />
Riser bend<br />
3-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/RB3/300.. OKA/RB3/350.. OKA/RB3/400..<br />
33260A ..60 33261A ..60 33262A ..60<br />
33260B .0.65 33261B .0.65 33262B ..65<br />
63
Open flushfloor trunking<br />
system – OKA/T –<br />
partition<br />
Partitions<br />
• Application<br />
To devide trunking lenght in tow or<br />
three compartments<br />
• Material<br />
– Partition: galvanised steel, 1 mm.<br />
MOQ = 1 piece<br />
slab bracket<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Partition<br />
Length = 2400 mm<br />
Length = 800 mm<br />
Length = 400 mm<br />
H = 60 mm<br />
H = 65 mm<br />
H = 60 mm<br />
H = 65 mm<br />
H = 60 mm<br />
H = 65 mm<br />
Size 300 Size 350<br />
Art. no. Code Art. no. Code<br />
OKA/TD..<br />
OKA/TD..<br />
33227AA ..1-60 33227AA ..1-60<br />
33227AB ..1-65 33227AB ..1.65<br />
OKA/TD..<br />
OKA/TD..<br />
33227BA ..2-60 33227BA ..2-60<br />
33227BB ..2-65 33227BB ..2-65<br />
OKA/TD..<br />
OKA/TD..<br />
33227CA ..3-60 33227CA ..3-60<br />
33227CB ..3-65 33227CB ..3-65<br />
Slab bracket<br />
<strong>for</strong> fixing on flat solid surfaces<br />
(ribbon screed) in packs of 6 pieces.<br />
H = 60 mm<br />
H = 65 mm<br />
33242A OKA/TF60 33242A OKA/TF60<br />
33242B OKA/TF65 33242B OKA/TF65<br />
64
Crossover 2-compartment<br />
Open flushfloor trunking<br />
system – OKA/T –<br />
Crossover, Crossing<br />
• Application<br />
Crossing of two trunking systems either same size or<br />
different size.<br />
• Material<br />
galvanised steel 1 mm<br />
MOQ = 1 piece<br />
Crossover 3-compartment<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Crossover set <strong>for</strong> crossing<br />
same size<br />
2-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
Size 300 Size 350 Size 400<br />
Art. no. Code Art. no. Code Art. no. Code<br />
OKA/CC2/300..<br />
OKA/CC2/350..<br />
33271AA .. 30060 33272BA .. 35060<br />
33271AB .. 30065 33272BB .. 35065<br />
Crossover set <strong>for</strong> crossing<br />
same size 300<br />
2-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
33272AA .. 35060<br />
33272AB .. 35065<br />
Crossover set <strong>for</strong> crossing<br />
same size<br />
3-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/CC3/300.. OKA/CC3/350.. OKA/CC3/400..<br />
33257AA .. 30060 33258BA .. 35060 32259CA .. 40060<br />
33257AB .. 30065 33258BB .. 35065 32259CB .. 40065<br />
Crossover set <strong>for</strong> crossing<br />
with size 350<br />
3-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
33232CA .. 35060<br />
33232CB .. 35065<br />
Crossover set <strong>for</strong> crossing<br />
with size 300<br />
3-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
33258AA .. 35060 33233CA .. 30060<br />
33258AB .. 35065 33233CB .. 30065<br />
65
Open flushfloor trunking<br />
system – OKA/T –<br />
Crossover, T-Branch<br />
Crossover set <strong>for</strong> Tee-branches<br />
2 compartment<br />
• Application<br />
T-Branch of two trunking systems either same size<br />
or different size.<br />
• Material<br />
galvanised steel 1 mm<br />
MOQ = 1 piece<br />
Crossover set <strong>for</strong> Tee-branches<br />
3 compartment<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Crossover set <strong>for</strong> Tee-branches<br />
same size<br />
2-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
Size 300 Size 350 Size 400<br />
Art. no. Code Art. no. Code Art. no. Code<br />
OKA/C2/300..<br />
OKA/C2/350..<br />
33269AA .. 30060 33270BA .. 35060<br />
33269AB .. 30065 33270BB .. 35065<br />
Crossover set <strong>for</strong> Tee-branches<br />
same size 300<br />
2-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
33270AA .. 35060<br />
33270AB .. 35065<br />
Crossover set <strong>for</strong> Tee-branches<br />
same size<br />
3-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/C3/300.. OKA/C3/350.. OKA/C3/400..<br />
33228AA .. 30060 33229BA .. 35060 33230CA .. 40060<br />
33228AB .. 30065 33229BB .. 35065 33230CB .. 40065<br />
Crossover set <strong>for</strong> Tee-branches<br />
with size 350<br />
3-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
33230BA .. 35060<br />
33230BB .. 35065<br />
Crossover set <strong>for</strong> Tee-branches<br />
with size 300<br />
3-compartment<br />
H = 60 mm<br />
H = 65 mm<br />
33229AA .. 35060 33230AA .. 30060<br />
33229AB .. 35065 33230AB .. 30065<br />
66
Carpet frame and lid<br />
assembly<br />
Open flushfloor trunking<br />
system – OKA/T –<br />
Service outlet<br />
• Material<br />
– Partition set: galvanised steel, 1 mm.<br />
– Service outlet: polyamide.<br />
Carpet frame and lid<br />
assembly<br />
Partition set <strong>for</strong> GES4OK<br />
2 compartment<br />
Partition set <strong>for</strong> GES9OK<br />
3 compartment<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Carpet frame and lid assembly<br />
<strong>for</strong> 2-compartment service outlet. Iron grey RAL 7011<br />
Graphite black RAL 9011<br />
Carpet frame and lid assembly<br />
<strong>for</strong> 3-compartment service outlet. Iron grey RAL 7011<br />
Graphite black RAL9011<br />
Art. no. Code MOQ<br />
30378A6 GES4OK7011 1<br />
30378F6 GES4OK9011 1<br />
30392A6 GES9OK7011 1<br />
30392F6 GES9OK9011 1<br />
Partition set <strong>for</strong> GES4OK<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/PS4/..<br />
43843A .. 60 1<br />
43843B .. 65 1<br />
Partition set <strong>for</strong> GES9OK<br />
H = 60 mm<br />
H = 65 mm<br />
OKA/PS9/..<br />
33227DA .. 60 1<br />
33227DB .. 65 1<br />
67
Open flushfloor trunking<br />
system – OKA/T –<br />
Mounting plates<br />
• Application<br />
To be used with service units GES4OK and<br />
GES9OK.<br />
• Dimensions<br />
in mm: 72.5 x 163<br />
Mounting plate<br />
Other mounting plates to suit most leading<br />
brands of telecommunication data or power<br />
outlets are available on request.<br />
Options, Spares<br />
screed anchor (optional)<br />
• Delivery<br />
– screed anchor supplied in packs of 6.<br />
– levelling bracket supplied in packs of 6.<br />
– earth conductor clamp supplied in packs of 10.<br />
OKA/T - Open flushfloor<br />
trunking system<br />
levelling bracket (optional)<br />
earth conductor clamp<br />
Art. no. Code MOQ<br />
Mounting plates <strong>for</strong><br />
GES4OK and GES9OK<br />
Blank<br />
Data 4 x RJ45<br />
2g SSO MK<br />
60501UA<br />
60501VA<br />
60501WA<br />
APMT2/0<br />
APMT2/1<br />
APMT2/2<br />
Screed anchor<br />
<strong>for</strong> optional use<br />
40092C EA6 6<br />
Levelling bracket<br />
<strong>for</strong> fixing and levelling of trunking sections<br />
(optional use)<br />
32856AV OKU/NEV110 6<br />
Earth conductor clamp – 8AWR –<br />
to be installed in trunking base.<br />
Suitable <strong>for</strong> 2 single wires 1.5 – 4 mm 2<br />
Material: galvanised steel. Supplied in packs of 10.<br />
35083CV 8AWR 10<br />
68
Installation of accessories<br />
OKA/T - Open flushfloor<br />
trunking system<br />
Elbow with 90° angle set<br />
69
The raised floor trunking system – RFT – provides a modular cable way <strong>for</strong> power, voice and data. Formed by<br />
header trunking and branch trunking, a network of cable paths is created beneath the raised floor tiles in the<br />
600 mm grid of the floor. “Crossovers” guarantee safe separation of the different current types at crossing points.<br />
The trunking system requires no additional cutting and is thus extremely installation-friendly, flexible and safe.<br />
70
Raised floor trunking system<br />
Raised floor trunking<br />
system and accessories from Page 72 - 73<br />
71
Raised floor installations<br />
Raised floor trunking system<br />
System height 40 mm<br />
Art. no. Code MOQ SI TI<br />
Raised floor trunking – RFTH./40 –<br />
header trunking with self contacting lids, with regular<br />
pre-punched openings <strong>for</strong> branch trunking (each 600<br />
mm), galvanised steel 1 mm.<br />
Dimensions:<br />
Length of base: 1,200 mm<br />
Length of lid: 600 mm<br />
Width of system:<br />
450 mm<br />
300 mm<br />
33276A RFTH450/40 1<br />
33275A RFTH300/40 1<br />
Raised floor trunking – RFTB225/40 –<br />
branch trunking with self contacting lids, with regular<br />
pre-punched conduit knock-outs M20 and M25,<br />
galvanised steel 1 mm.<br />
Dimensions:<br />
Length of base: 1,200 mm<br />
Length of lid: 600 mm<br />
Width of system:<br />
225 mm<br />
33277A RFTB225/40 1<br />
Raised floor trunking – RFTM450/40 –<br />
mock-up trunking <strong>for</strong> header trunking 450 mm, with self<br />
contacting lids, galvanised steel 1 mm.<br />
Dimensions:<br />
Length of base:<br />
Length of lid:<br />
Width of system:<br />
1,275 mm<br />
600 mm + 675 mm<br />
225 mm<br />
33277B RTFM450/40 1<br />
Raised floor trunking – RFTM300/40 –<br />
mock-up trunking <strong>for</strong> header trunking 300 mm, with self<br />
contacting lids, galvanised steel 1 mm.<br />
Raised floor<br />
trunking system<br />
Dimensions:<br />
Length of base:<br />
Length of lid:<br />
Width of system:<br />
1,350 mm<br />
600 mm + 750 mm<br />
225 mm<br />
End cup <strong>for</strong> raised floor trunking – ESRFT –<br />
<strong>for</strong> closing of raised floor header and branch trunkings.<br />
33277C RTFM300/40 1<br />
Material: galvanised steel, 1 mm.<br />
Suitable <strong>for</strong><br />
header trunking 450 mm<br />
header trunking 300 mm<br />
branch trunking 225 mm<br />
33281B ESRFT450/40 1<br />
33281A ESRFT300/40 1<br />
33281C ESRFT225/40 1<br />
Divider <strong>for</strong> raised floor trunking – TW/RFT –<br />
self contacting with trunking base during installation.<br />
Up to 2 dividers per trunking base are possible.<br />
Material: galvanised steel, 1 mm.<br />
L = 1,200 mm <strong>for</strong> header and branch<br />
L = 1,275 mm <strong>for</strong> Mock-up size 450 mm<br />
L = 1,350 mm <strong>for</strong> Mock-up size 300 mm<br />
33282A TWRFT1200 1<br />
33282B TWRFT1275 1<br />
33282C TWRFT1350 1<br />
Crossover <strong>for</strong> raised floor trunking – RFTC –<br />
<strong>for</strong> 4-way junction of header trunking with branch<br />
trunking.<br />
Material: galvanised steel, 1mm.<br />
Suitable <strong>for</strong> branch of trunking 450 with 225<br />
branch of trunking 300 with 225<br />
33279A RFTC450225 1<br />
33278A RFTC300225 1<br />
Earth conductor clamp – 8AWR –<br />
to be installed in raised floor trunking base.<br />
Suitable <strong>for</strong> 2 single wires 1.5 – 4 mm 2<br />
Material: galvanised steel.<br />
Supplied in packs of 10.<br />
35083CV 8AWR 10<br />
72
Raised floor installations<br />
Service outlet GES6 and accessories<br />
Art. no. Code MOQ SI TI<br />
Raised floor box – GES6DB –<br />
3 compartments, with 4 mm galvanised steel load plate, 5 mm<br />
recess, 95 mm deepness.<br />
Dimensions (in mm):<br />
outside: 274 x 220<br />
cut-out: 253 x 200<br />
Iron grey RAL 7011<br />
Graphite black RAL 9011<br />
30334A1 GES6DB7011 1<br />
30344F1 GES6DB9011 1<br />
Mounting tray – MT2BS2/6 –<br />
3-compartment, to fix under GES6DB raised floor box, with<br />
removable divider. Each compartment with<br />
4 knock-outs 2 x M20 and 2 x M25<br />
Material: 1 mm galvanised steel.<br />
30383A MT2BS2/6 1<br />
Mounting plate blank – APMT2/0 –<br />
to cover a complete compartment.<br />
Delivery includes fixing screws.<br />
Material: 1.2 mm galvanised steel, coated.<br />
Dimension L x W in mm: 163 x 72.5<br />
60501UA APMT2/0 1<br />
Mounting plate 4 x RJ45 – APMT2/1 –<br />
For installation of 4 x RJ45 or LJU6C data jacks.<br />
Delivery includes fixing screws.<br />
Material: 1.2 mm galvanised steel, coated.<br />
Dimension L x W in mm: 163 x 72.5<br />
60501VA APMT2/1 1<br />
Raised floor<br />
trunking system<br />
Mounting plate socket outlet – APMT2/1 –<br />
<strong>for</strong> installation of double switched socket outlet (MK).<br />
Delivery includes fixing screws.<br />
Material: 1.2 mm galvanised steel, coated.<br />
Dimension L x W in mm: 163 x 72.5<br />
60501WA APMT2/2 1<br />
Other mounting plates to suit most leading brands of telecommunication<br />
data or power outlets are available on request.<br />
73
Service units<br />
Dome lids from Seite 78<br />
GESRM2 service unit from Seite 79<br />
Service unit rectangular from Page 80 - 81<br />
Service units round<br />
and accessories from Page 82 - 84<br />
Inserts <strong>for</strong> junction<br />
boxes ZES from Page 85<br />
Height adjustable cassettes from Page 86 - 89<br />
Service unit <strong>for</strong><br />
wet-cleaned<br />
floors GRAF9 from Page 90 - 91<br />
Mounting box GB2<br />
<strong>for</strong> service units and<br />
cover plates from Page 92 - 93<br />
Mounting box GB3 <strong>for</strong><br />
service units and<br />
cover plates from Page 94 - 95<br />
Mounting trays <strong>for</strong><br />
data modules from Page 96<br />
Mounting trays <strong>for</strong><br />
service units from Page 97<br />
75
Underfloor service units<br />
Used in dry-cleaned floors<br />
GES9M10 –<br />
Metal service unit<br />
GESR9SR –<br />
Service unit with hinged cover and<br />
carpet protection frame<br />
Used in wet-cleaned floors<br />
Service units<br />
SHF80 and BABF –<br />
flush-mount unit <strong>for</strong> a single<br />
device, blindcover<br />
GRAF9 –<br />
Aluminium die-cast service unit<br />
76
Underfloor service units<br />
GESR.2 Service unit<br />
Applications<br />
Use in dry-cleaned floors <strong>for</strong> the installation<br />
of a power socket and up to two RJ45<br />
sockets.<br />
Version<br />
The service unit consists of:<br />
– installation housing with floor covering<br />
protection frame<br />
– mounting ring, <strong>for</strong> raised floor version<br />
with clamping bracket<br />
– captive hinged cover with 2-level lock<br />
– mounting box with single power socket,<br />
installation space <strong>for</strong> data connection<br />
sockets blanked off<br />
Visible surfaces with galvanic surface<br />
finishing with old brass, nickel, chromium<br />
or old copper.<br />
Material<br />
– Installation housing and cover: Die-cast<br />
zinc.<br />
– mounting box: Polyamide.<br />
Note<br />
Can also be wet-cleaned when unused.<br />
Service units<br />
77
Underfloor service units<br />
Protective unit cover <strong>for</strong> use in<br />
dry rooms with dry or wet-cleaned floors<br />
Art. no. Code MOQ SI TI<br />
HB<br />
1<br />
3<br />
2<br />
EÜK<br />
DB<br />
Single outlet - US80 -<br />
<strong>for</strong> installation of a single installation unit or<br />
fixing a Telitank.<br />
Material: Die-cast zinc.<br />
Applications Installation opening Plate thickness<br />
EÜK<br />
Ø 95 mm<br />
HB<br />
Ø 95 mm<br />
DB Ø 91.2mm 38 mm<br />
DB Ø 91.2mm 60 mm<br />
30277A US80/32 1 X –<br />
57148 USS80-W 1 –<br />
34504A US80/DB20 1 –<br />
34504B US80/DB38 1 –<br />
Underfloor outlet box - UDL2-80 -<br />
<strong>for</strong> installation of SH or SHF unit protection cover.<br />
2x2 openings <strong>for</strong> M20 or Pg16 pipe installations.<br />
For screed heights of 70 to 85 mm<br />
30220C UDL2-80/70 1 X –<br />
Caution<br />
Mounting protection cover only <strong>for</strong> cover during<br />
the mounting phase.<br />
Protective unit cover - SH80A -<br />
Protruding height: 26mm.<br />
External dimensions: ø 104 mm.<br />
Material: polyamide, in colours:<br />
Floor covering < 6 mm Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
Floor covering > 6 mm Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30241A SH80/7011 1 X –<br />
30241F SH80/9011 1 X –<br />
30241A1 SH80T7011 1 X –<br />
30241F1 SH80T9011 1 X –<br />
Device cover plate<br />
<strong>for</strong> installation of a device into US80 or UDL2-80.-<br />
– US80A –<br />
<strong>for</strong> installation unit with support ring or clip.<br />
– US80B –<br />
<strong>for</strong> single power socket of type Module45.<br />
55539 US80A 1 X –<br />
30323AA US80A 1 X –<br />
Service units<br />
Blanking cover - BA80N -<br />
with floor covering recess (5 mm deep), can be screwed<br />
into US80.. single outlet or UDL2-80/70<br />
<strong>underfloor</strong> outlet box.<br />
Visible frame width: 10 mm.<br />
External dimensions: ø 100 mm. Material: Polyamide.<br />
Colours, matt visible surface:<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
Protective unit cover <strong>for</strong> use in wet-cleaned floors<br />
according to DIN VDE 0634 Part 1.<br />
Protruding height: 57 mm.<br />
External dimensions: ø 112 mm.<br />
Colour: Graphite black, RAL 9011.<br />
30028A BABN80/7011 1 X –<br />
30028F BABN80/9011 1 X –<br />
– SHF80/30 –<br />
with ribbed-rein<strong>for</strong>cement ring made of polyamide and<br />
profile rubber seal.<br />
30246E1 SHF80/30/9011 1 X –<br />
– SHF80/30 M –<br />
As above, insulating material ring covered with Nirosta<br />
ring.<br />
30246E3 SHF80/30M9011 1 X –<br />
Blanking cover with moisture protection - BABF -<br />
<strong>for</strong> flush-floor closing of the US80 and the UDL2-80/70.<br />
With rubber seal.<br />
External dimensions: ø 112 mm.<br />
Nickel<br />
Chromium<br />
Old brass<br />
Old copper<br />
30247D BABF80NI 1 X –<br />
30247E BABF80CR 1 X –<br />
30247F BABF80AM 1 X –<br />
30247G BABF80AK 1 X –<br />
78
Underfloor service units<br />
Service outlet GESRM2<br />
<strong>for</strong> installation in UZD190, UDL2-120<br />
and raised floor<br />
Service outlet – GESR.2US –<br />
with carpet protection frame <strong>for</strong> installation in <strong>underfloor</strong> outlet<br />
box UDL2-120.<br />
Pre-equipped with power socket VDE.<br />
Installation diameter Ø 120 mm.<br />
Surface in<br />
Nickel<br />
Old brass<br />
Old copper<br />
Chrome<br />
Service outlet – GESR.2US –<br />
with carpet protection frame <strong>for</strong> installation in raised floor.<br />
Pre-equipped with power socket VDE.<br />
Installation diameter Ø 120 mm.<br />
Surface in<br />
Nickel<br />
Old brass<br />
Old copper<br />
Chrome<br />
Service outlet – GESR.2US –<br />
with carpet protection frame <strong>for</strong> installation in <strong>underfloor</strong> outlet<br />
box UDL2-120. Pre-equipped with switched socket outlet,<br />
British Standard, 3pin.<br />
Installation diameter Ø 120 mm.<br />
Surface in<br />
Nickel<br />
Old brass<br />
Old copper<br />
Chrome<br />
Service outlet – GESR.2US –<br />
with carpet protection frame <strong>for</strong> installation in raised floor.<br />
Pre-equipped with switched socket outlet,<br />
British Standard, 3pin.<br />
Installation diameter Ø 120 mm.<br />
Surface in<br />
Nickel<br />
Old brass<br />
Old copper<br />
Chrome<br />
Service outlet – GESR.2US –<br />
with carpet protection frame <strong>for</strong> installation in <strong>underfloor</strong> outlet<br />
box UDL2-120.<br />
Pre-equipped with socket outlet with earth pin.<br />
Installation diameter Ø 120 mm.<br />
Surface in<br />
Service outlet – GESR.2US –<br />
with carpet protection frame <strong>for</strong> installation in raised floor.<br />
Pre-equipped with socket outlet. With earth pin.<br />
Installation diameter Ø 120 mm.<br />
Surface in<br />
Nickel<br />
Old brass<br />
Old copper<br />
Chrome<br />
<br />
Protection frame design<br />
˜ 5 mm<br />
For a system description, please see Page 73.<br />
Art. no. Code MOQ SI TI<br />
30889DA GESRN2USB 1 X<br />
30889GA GESRM2USB 1 X<br />
30889CA GESRK2USB 1 X<br />
30889EA GESRC2USB 1 X<br />
<br />
Nickel<br />
Old brass<br />
Old copper<br />
Chrome<br />
Underfloor outlet box – UDL2-120 –<br />
<strong>for</strong> installation of a GESRM2 service unit.<br />
For conduit installation M20 oder Pg16.<br />
Material: pre-galvanised metal sheet box sealed with assembly<br />
protection cover.<br />
<strong>for</strong> screed heights of 70 to mm<br />
<strong>for</strong> screed heights of 80 to 95 mm<br />
30890DA GESRN2UAB 1 X<br />
30890GA GESRM2UAB 1 X<br />
30890CA GESRK2UAB 1 X<br />
30890EA GESRC2UAB 1 X<br />
30961DA GESRN2USBBSS 1<br />
30961GA GESRM2USBBSS 1<br />
30961CA GESRK2USBBSS 1<br />
30961EA GESRC2USBBSS 1<br />
30962DA GESRN2UABBSS 1<br />
30962GA GESRM2UABBSS 1<br />
30962CA GESRK2UABBSS 1<br />
30962EA GESRC2UABBSS 1<br />
30955DA GESRN2USBN 1<br />
30955GA GESRM2USBN 1<br />
30955CA GESRK2USBN 1<br />
30955EA GESRC2USBN 1<br />
30957DA GESRN2UABN 1<br />
30957GA GESRM2UABN 1<br />
30957CA GESRK2UABN 1<br />
30957EA GESRC2UABN 1<br />
30220A UDL2-120/70 1 X<br />
30220B UDL2-120/80 1 X<br />
79<br />
Service units
Service unit in <strong>underfloor</strong> systems and raised floor<br />
systems dry-cleaned floors only<br />
Service units GES2, 4, 6, 9<br />
Dry-cleaned floors<br />
Flush floor service unit GES2, 4, 4/10, 6, 6/10, 9<br />
Application<br />
Use in dry-cleaned floors <strong>for</strong> the fitting of installation<br />
devices in insulated mounting boxes.<br />
The number of individual installation devices to be fitted is as<br />
follows:<br />
– GES 2: 2 units<br />
– GES 4 and GES 4/10: 4 units<br />
– GES 6 and GES 6/10: 6 units<br />
– GES 9: 9 units<br />
If using multiple installation devices, the number of<br />
connections available increases accordingly.<br />
Design<br />
Flush floor service units consist of:<br />
– carpet protection frame, including fitting bracket<br />
– mounting box insert frame with ladders to lower the mounting<br />
box in 5 mm increments to a max. of 20 mm.<br />
– hinged cover (captive in carpet protection frame, closes<br />
automatically), including:<br />
– 4 mm steel plate.<br />
– cord cap with foam seal.<br />
– adjustable handle to open the cover.<br />
Carpet recess: 5 mm, 10 mm only <strong>for</strong> …/10 flush floor<br />
service unit.<br />
Minimum fitting depth <strong>for</strong> flush floor service unit: 70 mm,<br />
75 mm <strong>for</strong> GES 4/10 and GES 6/10.<br />
Material<br />
Carpet protection frame and cover with cord cap:<br />
polyamide.<br />
All flush floor service units are halogen-free.<br />
Flush floor service unit – GES2 –<br />
<strong>for</strong> 2 installation devices in 1 GB 2 mounting box.<br />
External dimensions in mm: L = 194, W = 118.<br />
Installation opening in mm: L = 198, W = 105.<br />
Standard colours:<br />
Iron grey RAL 7011<br />
Graphite RAL 9011<br />
Flush floor service unit – GES4 –<br />
<strong>for</strong> 4 installation devices in 2 GB 2 mounting box.<br />
Installation opening in mm: L = W = 201.<br />
– GES4 –<br />
with 5 mm carpet recess.<br />
External dimensions in mm: L = W = 217.<br />
Standard colours: Iron grey RAL 7011<br />
Graphite RAL 9011<br />
– GES4/10 –<br />
with 10 mm floor covering recess.<br />
External dimensions in mm: L = W = 220.<br />
Standard colours: Iron grey RAL 7011<br />
Graphite RAL 9011<br />
– GES4M10 –<br />
V2A, 10 mm floor covering recess in<br />
hinged cover.<br />
Flush floor service unit – GES6 –<br />
<strong>for</strong> 6 installation devices in 3 GB 2 mounting box.<br />
Installation opening in mm: L = 253, W = 200.<br />
– GES6 –<br />
with 5 mm floor covering recess.<br />
External dimensions in mm: L = 270, W = 215.<br />
Standard colours: Iron grey RAL 7011<br />
Graphite RAL 9011<br />
– GES6/10<br />
with 10 mm floor covering recess.<br />
External dimensions in mm: L = 276, W = 220.<br />
Standard colours: Iron grey RAL 7011<br />
Graphite RAL 9011<br />
– GES6M10 –<br />
V2A, 10 mm floor covering recess in<br />
hinged cover.<br />
Service units<br />
Flush floor service unit – GES9 –<br />
<strong>for</strong> 9 installation devices in 3 GB 3 mounting box.<br />
External dimensions in mm: L = W = 263.<br />
Installation opening in mm: L = W = 243.<br />
– GES9 –<br />
Standard colours: Iron grey RAL 7011<br />
Graphite RAL 9011<br />
– GES9M10 –<br />
V2A, 10 mm floor covering recess in<br />
hinged cover.<br />
Slot in cable extension – GES/RV –<br />
<strong>for</strong> additional lowering of the mounting box by max.<br />
25 mm. Fits all flush-floor service units.<br />
Supplied in packs of 2.<br />
80
Raised floor<br />
Art. no. Code MOQ SI TI<br />
EÜK, OKA/T<br />
Art. no. Code MOQ SI TI<br />
GES2DB..<br />
30700A1 ..7011 1 X<br />
30700F1 ..9011 1 X<br />
GES2U..<br />
30700A6 ..7011 X<br />
30700F6 ..9011 1 X<br />
GES4DB..<br />
30706A1 ..7011 1 X<br />
30706F1 ..9011 1 X<br />
GES4U..<br />
30706A6 ..7011 1 X<br />
30706F6 ..9011 1 X<br />
– – – –<br />
– – – –<br />
GES4/10U..<br />
30936A6 ..7011 1 X<br />
30936F6 ..9011 1 X<br />
GES4M10..<br />
30343A1 ..DB/HB 1 X<br />
30343A6 GES4MU10 1 X<br />
GES6DB..<br />
30334A1 ..7011 1 X<br />
30334F1 ..9011 1 X<br />
GES6U..<br />
30334A6 ..7011 1 X<br />
30334F6 ..9011 1 X<br />
– – – –<br />
– – – –<br />
GES6/10U..<br />
30937A6 ..7011 1 X<br />
30937F6 ..9011 1 X<br />
GES6M10..<br />
30344A1 ..DB/HB 1 X<br />
30344A6 GES6MU10 1 X<br />
Service units<br />
GES9DB..<br />
30332A1 ..7011 1 X<br />
30332F1 ..9011 1 X<br />
GES9M10..<br />
30345A1 ..DB/HB 1 X<br />
GES9U..<br />
30332A6 ..7011 1 X<br />
30332F6 ..9011 1 X<br />
30345A6 GES9MU10 1 X<br />
30768A1 GES/RV 1 X 30768A1 GES/RV 1 X<br />
81
Service unit in <strong>underfloor</strong> systems and raised<br />
floor systems dry-cleaned floors only<br />
Service units GESR4, R7, R9<br />
Application<br />
use in dry-cleaned floors <strong>for</strong> installation of<br />
devices in insulated mounting boxes.<br />
The number of individual devices to be installation is:<br />
GESR4:<br />
4 units<br />
GESR7 and GESRA7/10: 7 units<br />
GESR9 and GESRA9: 9 units<br />
If multiple installation units are used, then the number of connection options increases.<br />
Design<br />
Flush floor service units consist of:<br />
– carpet protection frame, including fitting bracket<br />
– mounting box insert frame with ladders to lower the mounting box in 5 mm<br />
increments to a max. of 20 mm.<br />
– hinged cover (captive in carpet protection frame, closes automatically), including:<br />
– 4 mm steel plate.<br />
– cord cap with foam seal.<br />
– adjustable handle to open the cover.<br />
Material<br />
– GESR.: Carpet protection frame and hinged cover with cord outlet made of<br />
polyamide.<br />
– GESRA7/10: Carpet protection frame and hinged cover made of die-cast aluminium,<br />
cord outlet made of polyamide.<br />
– GESRA9/10: Carpet protection frame and hinged cover with cord outlet made of<br />
die-cast aluminium.<br />
Note <strong>for</strong> GESR7/10<br />
The floor covering recess can be deepened from 5 mm to 10 mm.<br />
The UDB conversion set is required <strong>for</strong> this (UDB: 40104 DE).<br />
For mounting boxs, mounting box cover plates, see Page 92ff.<br />
All the service units are halogen-free.<br />
Recess in the floor covering: 5 mm; 10 mm <strong>for</strong> GESR(A)7/10, GESR9/10<br />
and GESRA9/10.<br />
Minimum installation height:<br />
– 70 mm <strong>for</strong> service units with 5 mm floor covering recess in hinged cover<br />
– 75 mm <strong>for</strong> service units with 10 mm floor covering recess in hinged cover.<br />
External dimensions of round service units<br />
GESR4<br />
GESR7/10<br />
GESRA7/10<br />
Service units<br />
206,50<br />
200,50<br />
74<br />
228<br />
268,2<br />
264<br />
111<br />
294<br />
268,2<br />
261<br />
111<br />
294<br />
165<br />
214<br />
214<br />
GESR9 GESR9SR GESR9/10<br />
GESRA9/10<br />
294,5<br />
289<br />
111<br />
324<br />
294,5<br />
283<br />
117<br />
324<br />
299<br />
293<br />
324<br />
295<br />
287<br />
323<br />
241,5<br />
245,5<br />
241<br />
82
Service unit in <strong>underfloor</strong> systems and raised<br />
floor systems dry-cleaned floors only<br />
Service units GESR4, R7, R9<br />
Art. no. Code MOQ SI TI<br />
Service unit - GESR4U -<br />
with hinged cover <strong>for</strong> four installation units in two<br />
GB2 mounting boxes.<br />
Installation dimensions in mm: Ø 215.<br />
External dimensions in mm: Ø 228.<br />
Polyamide, 5 mm floor covering recess<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30713A6 GESR4U7011 1 X 82<br />
30713F6 GESR4U9011 1 X 82<br />
Service unit - GESR7U -<br />
<strong>for</strong> seven installation units in two GB2 mounting boxes<br />
and one GB3 mounting box.<br />
Installation opening in mm: Ø 275.<br />
– GESR7/10 –<br />
with hinged cover, Polyamide, 10 mm floor covering recess<br />
reduced to 5 mm.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
– GESRA7/10 –<br />
with hinged cover, Aluminium, 10 mm floor covering recess<br />
30871A6 GESR7/10U7011 1 X 82<br />
30871F6 GESR7/10U9011 1 X 82<br />
30868A6 GESRA7/10U 1 X 82<br />
– GESRA7D –<br />
with structured hinged cover, Aluminium reccesses in<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
– GESRA7DM –<br />
with structured hinged cover, Aluminium<br />
bright metal.<br />
Cord outlet in<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30869A6 GESRA7D/U7011 1 X 82<br />
30869F6 GESRA7D/U9011 1 X 82<br />
30873A6 GESRA7DM/U7011 1 X 82<br />
30873F6 GESRA7DM/U9011 1 X 82<br />
Service unit - GESR9U -<br />
<strong>for</strong> nine installation units in three GB3 mounting boxes.<br />
Installation dimensions in mm: ø 305 mm.<br />
– GESR9U –<br />
with hinged cover, Polyamide, 5 mm floor covering recess<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30331A6 GESR9U7011 1 X 82<br />
30331F6 GESR9U9011 1 X 82<br />
Service units<br />
– GESR9SR –<br />
with hinged cover, Polyamide, 5 mm floor covering recess<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30365A6 GESR9SR/U7011 1 X 82<br />
30365F6 GESR9SR/U9011 1 X 82<br />
– GESR9/10 –<br />
with hinged cover, Polyamide, 10 mm floor covering recess<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30368A6 GESR9/10U7011 1 X 82<br />
30368F6 GESR9/10U9011 1 X 82<br />
– GESRA9/10 –<br />
with hinged cover, Aluminium, 10 mm floor covering recess<br />
30369A6 GESRA9/10U 1 X 82<br />
83
Service unit in <strong>underfloor</strong> systems and raised<br />
floor systems dry-cleaned floors only<br />
GES accessories<br />
Art. no. Code MOQ SI TI<br />
Filling piece - FSR9/10/5 -<br />
to reduce the floor covering recess in the hinged cover<br />
of the service unit GESR9/10.<br />
One-sided coating with double-sided adhesive surface.<br />
Material: card.<br />
Thickness in mm: 5<br />
Suitable <strong>for</strong>:<br />
GESR9/10<br />
30379A FSR9/10/5 1 –<br />
Suitable <strong>for</strong>:<br />
GESRA9/10<br />
30379B FSRA9/10/5 1 –<br />
Insertion plate - EPQR. –<br />
<strong>for</strong> surface-flush insertion in a round service unit. Use<br />
only in conjunction with filling piece.<br />
Material: Quintet checker plate, aluminium.<br />
Thickness: 5 mm.<br />
Suitable <strong>for</strong>:<br />
GESR9/10<br />
GESRA9/10<br />
30380A EPQRR9/10 1 –<br />
30380B EPQRRA9/10 1 –<br />
Suitable <strong>for</strong>:<br />
GESR9<br />
GESRA7/10<br />
30380C EPQRR9 1 –<br />
30380D EPQRR7 1 –<br />
Space cover - LPA. –<br />
To close off an unused installation location <strong>for</strong> an<br />
mounting box.<br />
GB2<br />
GB3<br />
30797A LPAGB2 1 –<br />
30797B LPAGB3 1 –<br />
Service units<br />
Conversion set - UDB -<br />
to change the floor covering recess in the<br />
GESR7 hinged cover from 5 mm to 10 mm.<br />
40104DE UDB 1 –<br />
<strong>Cable</strong> routing clamp - KFBR9 -<br />
<strong>for</strong> installation in a GESR9 service unit.<br />
30370A KFBR9 10 –<br />
84
Junction-box inserts and inspection covers<br />
<strong>for</strong> dry-cleaned floors.<br />
ZES4, 6, 9, R4, R7, R9<br />
floor covering<br />
recess 5 mm<br />
ZES..<br />
floor covering<br />
5<br />
4 12<br />
3<br />
4 mm cover plate<br />
leveling plate<br />
service outlet<br />
floor covering<br />
recess 10 mm<br />
ZES../10<br />
10<br />
4 17<br />
3<br />
Art. no. Code MOQ SI TI<br />
Junction box inserts – ZES –<br />
<strong>for</strong> blanking off empty <strong>underfloor</strong> sockets (UGD);<br />
Consisting of:<br />
– carpet protection frame including universal fastening bracket,<br />
– blanking cover made of 4 mm steel plate,<br />
– recess in the floor covering: 5 mm; 10 mm only <strong>for</strong> draw-box inserts ../10.<br />
The junction box inserts/carpet protection frame and service units have the same installation<br />
dimensions and external dimensions.<br />
– ZES4U –<br />
Installation dimension in mm: L = W = 201.<br />
Polyamide, 5 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
– ZES4/10U –<br />
Polyamide, 10 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
– ZESR4U –<br />
Installation diameter in mm: Ø 215.<br />
Polyamide, 5 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30779A6 ZES4U7011 1 –<br />
30779F6 ZES4U9011 1 –<br />
30790A6 ZES4/10U7011 1 –<br />
30790F6 ZES4/10U9011 1 –<br />
30789A6 ZESR4U7011 1 –<br />
30789F6 ZESR4U9011 1 –<br />
– ZES6U –<br />
Installation dimension in mm: L = 253; W = 200.<br />
Polyamide, 5 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
– ZES6/10U –<br />
Polyamide, 10 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
– ZESR7U –<br />
Installation diameter in mm: Ø 275.<br />
Polyamide, 5 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30780A6 ZES6U7011 1 –<br />
30780F6 ZES6U9011 1 –<br />
30791A6 ZES6/10U7011 1 –<br />
30791F6 ZES6/10U9011 1 –<br />
30872A6 ZESR7/10U7011 1 –<br />
30872F6 ZESR7/10U9011 1 –<br />
Service units<br />
– ZESRA7U –<br />
Installation diameter in mm: Ø 275.<br />
Aluminium, 10 mm floor covering recess.<br />
– ZES9U –<br />
Installation dimension in mm: L = W = 244.<br />
Polyamide, 5 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30870A6 ZESRA7/10U 1 –<br />
30785A6 ZES9U7011 1 –<br />
30785F6 ZES9U9011 1 –<br />
– ZESR9U –<br />
Installation diameter in mm: Ø 305.<br />
Polyamide, 5 mm floor covering recess.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30803A6 ZESR9U7011 1 –<br />
30803F6 ZESR9U9011 1 –<br />
85
Installation of devices in <strong>underfloor</strong> systems<br />
and raised floor <strong>for</strong> dry and wet-cleaned floors<br />
Square cassettes with levelling unit<br />
201<br />
244<br />
Mounting opening<br />
Tube mounting<br />
Service units<br />
D<br />
B<br />
A<br />
C<br />
A<br />
C<br />
Permanently elastic joint compound<br />
Inner dimensions of the cassettes <strong>for</strong><br />
floor covering (clearances in mm)<br />
Cut-out <strong>for</strong> Tube in floor covering approx.<br />
Ø 100 mm<br />
Nominal size A B C D<br />
4 190 Ø 95-100 43 41<br />
9 234 Ø 95-100 59 41<br />
86
Installation of devices in <strong>underfloor</strong> systems<br />
and raised floor <strong>for</strong> dry and wet-cleaned floors<br />
Square cassettes with levelling unit<br />
Levelling unit<br />
Height levelling<br />
Cassette <strong>for</strong> floor covering thickness<br />
20 mm 25 mm<br />
Included in delivery max. 150 mm max.155 mm<br />
RKNEV110 (30116BV) 145 + 40 mm 150 + 40 mm<br />
RKNEV150 (30116CV) 185 + 40 mm 190 + 40 mm<br />
Art. no. Code MOQ SI TI<br />
“Blank” square cassette<br />
<strong>for</strong> inspection openings in dry or wetcleaned<br />
floors, only <strong>for</strong> smooth floor coverings.<br />
- RKN4 -<br />
Installation diameter in mm: L = W = 201.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
- RKN9 -<br />
Installation diameter in mm: L = W = 244.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
30147C RKN4VS20 1 X -<br />
30147D RKN4VS25 1 X -<br />
30148C RKN4MS20 1<br />
30148D RKN4MS25 1<br />
30151C RKN9VS20 1 X -<br />
30151D RKN9VS25 1 X -<br />
30152C RKN9MS20 1<br />
30152D RKN9MS25 1<br />
Square cassette with cord outlet<br />
<strong>for</strong> installation of units in dry-cleaned floors. Cassette cover with<br />
hinge function, metal cord outlet.<br />
- RKSN4 -<br />
Installation diameter in mm: L = W = 201.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
- RKSN9 -<br />
Installation diameter in mm: L = W = 244.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
30159C RKSN4VS20 1 X -<br />
30159D RKSN4VS25 1 X -<br />
30160C RKSN4MS20 1<br />
30160D RKSN4MS25 1<br />
30163C RKSN9VS20 1 X -<br />
30163D RKSN9VS25 1 X -<br />
30164C RKSN9MS20 1<br />
30164D RKSN9MS25 1<br />
Square cassette <strong>for</strong> Tube<br />
<strong>for</strong> installation of units in wet-cleaned floors.<br />
Note: Order the Tube separately.<br />
- RKFN4 -<br />
Installation diameter in mm: L = W = 201.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
- RKFN9 -<br />
Installation diameter in mm: L = W = 244.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Tube - TUK -<br />
<strong>for</strong> installation in the cassette <strong>for</strong> the RKF Tube.<br />
– Material: Polyamide.<br />
Tube with V2A handle clip and cover,<br />
Tube in Iron grey, RAL 7011<br />
Tube in Graphite black, RAL 9011<br />
Tube with MS handle clip and cover<br />
Tube in Sepia brown, RAL 8014<br />
Tube in Grey beige, RAL 1019<br />
– Material: Aluminium natural anodised<br />
30153C RKFN4VS20 1 X -<br />
30153D RKFN4VS25 1 X -<br />
30154C RKFN4MS20 1<br />
30154D RKFN4MS25 1<br />
30157C RKFN9VS20 1 X -<br />
30157D RKFN9VS25 1 X -<br />
30158C RKFN9MS20 1<br />
30158D RKFN9MS25 1<br />
30374AA TUKV7011 1 X -<br />
30374AF TUKV9011 1 X -<br />
30374BC TUKM8014 1 X -<br />
30374BE TUKM1019 1 X -<br />
30117A1 TUKA 1 X -<br />
Service units<br />
Levelling unit - RKNEV -<br />
<strong>for</strong> height adjustment of the square<br />
cassette units to other installation heights.<br />
Mounting set: 4 units.<br />
Levelling height 145 + 50 mm<br />
185 + 50 mm<br />
30116BV RKNEV110 1 X -<br />
30116CV RKNEV150 1 X -<br />
Rig - AS -<br />
to support the square cassette with<br />
cord outlet when cover is open.<br />
With fixing material.<br />
Suitable <strong>for</strong> nominal sizes<br />
RKSN4<br />
RKSN9<br />
30387AA AS4 1 -<br />
30387AB AS9 1 -<br />
87
Installation of devices in <strong>underfloor</strong> systems<br />
and raised floor <strong>for</strong> dry and wet-cleaned floors<br />
Round cassettes with levelling unit<br />
floor covering<br />
tube<br />
floor covering<br />
Permanently elastic<br />
joint compound<br />
Service units<br />
floor covering<br />
Permanently elastic<br />
joint compound<br />
Type A B<br />
RKFR4 197 95-100<br />
RKFR7 257 95-100<br />
RKFR9 287 95-100<br />
RKR4 197 –<br />
RKR7 257 –<br />
RKR9 287 –<br />
88
Installation of devices in <strong>underfloor</strong> systems<br />
and raised floor <strong>for</strong> dry and wet-cleaned floors<br />
Round cassettes with levelling unit<br />
Levelling unit<br />
Height levelling<br />
Cassette <strong>for</strong> floor covering thickness<br />
20 mm 25 mm<br />
Included in delivery max. 155 mm max. 155 mm<br />
RKNEV110 (30116BV) 145 + 40 mm 150 + 40 mm<br />
RKNEV150 (30116CV) 185 + 40 mm 190 + 40 mm<br />
Art. no. Code MOQ SI TI<br />
“Blank” round cassette<br />
<strong>for</strong> inspection openings. With cassette <strong>for</strong> wood,<br />
ceramic and stone coverings, only <strong>for</strong> smooth floor coverings.<br />
- RKN4 -<br />
Installation diameter in mm: Ø 215.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
- RKR9 -<br />
Installation diameter in mm: Ø 275.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
- RKR9 -<br />
Installation diameter in mm: Ø 305.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
Round cassette with cord outlet<br />
<strong>for</strong> installation of units in dry-cleaned floors.<br />
30098B RKR4V20 1 32<br />
30098C RKR4V25 1 32<br />
30099B RKR4M20 1 32<br />
30099C RKR4M25 1 32<br />
30100B RKR7V20 1 32<br />
30100C RKR7V25 1 32<br />
30101B RKR7M20 1 32<br />
30101C RKR7M25 1 32<br />
30102B RKR9V20 1 X 32<br />
30102C RKR9V25 1 X 32<br />
30103B RKR9M20 1 32<br />
30103C RKR9M25 1 32<br />
- RKSR4 -<br />
Installation diameter in mm: Ø 215.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
- RKSR7 -<br />
Installation diameter in mm: Ø 275.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
- RKSR9 -<br />
Installation diameter in mm: Ø 305.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
Round cassette <strong>for</strong> Tube<br />
<strong>for</strong> installation of units in wet-washed floors. Note: Order the Tube<br />
separately.<br />
- RKFR4 -<br />
Installation diameter in mm: Ø 215.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
- RKFR7 -<br />
Installation diameter in mm: Ø 275.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
- RKFR9 -<br />
Installation diameter in mm: Ø 305.<br />
Material V2A, <strong>for</strong> floor covering thickness in mm: 20<br />
25<br />
Material: brass, floor covering thickness in mm: 20<br />
25<br />
Tube - TUK -<br />
<strong>for</strong> installation in the cassette <strong>for</strong> the RKFR Tube.<br />
Material: polyamide with covering made of:<br />
V2A, Tube in Iron grey, RAL 7011<br />
V2A, Tube in Graphite black, RAL 9011<br />
MS, Tube in Sepia brown, RAL 8014<br />
MS, Tube in Grey beige, RAL 1019<br />
MS, Tube in Graphite black, RAL 9011<br />
Levelling unit - RKNEV -<br />
<strong>for</strong> height adjustment of the round cassette units to other installation<br />
heights.<br />
30104C RKSR4V20 1 32<br />
30104D RKSR4V25 1 32<br />
30105C RKSR4M20 1 32<br />
30105D RKSR4M25 32<br />
30106C RKSR7V20 1 32<br />
30106D RKSR7V25 1 32<br />
30107C RKSR7M20 1 32<br />
30107D RKSR7M25 1 32<br />
30108C RKSR9V20 1 X 32<br />
30108D RKSR9V25 1 X 32<br />
30109C RKSR9M20 1 32<br />
30109D RKSR9M25 1 32<br />
30110B RKFR4V20 1 32<br />
30110C RKFR4V25 1 32<br />
30111B RKFR4M20 1 32<br />
30111C RKFR4M25 1 32<br />
30112B RKFR7V20 1 32<br />
30112C RKFR7V25 1 32<br />
30113B RKFR7M20 1 32<br />
30113C RKFR7M25 1 32<br />
30114B RKFR9V20 1 32<br />
30114C RKFR9V25 1 32<br />
30115B RKFR9M20 1 32<br />
30115C RKFR9M25 1 32<br />
30374AA TUKV7011 1 X 32<br />
30374AF TUKV9011 1 X 32<br />
30374BC TUKM8014 1 X 32<br />
30374BE TUKM1019 1 X 32<br />
30374BF TUKM9011 1 X 32<br />
Service units<br />
Mounting set: 4 units.<br />
Levelling height in mm 145 + 50<br />
185 + 50<br />
30116BV RKNEV110 1 X –<br />
30116CV RKNEV150 1 X –<br />
89
Installation of devices in <strong>underfloor</strong><br />
systems and raised floor <strong>for</strong> dry and<br />
wet-cleaned floors<br />
Service unit GRAF9<br />
Service units<br />
Application<br />
Use in wet-cleaned floors <strong>for</strong> installation of<br />
devices in insulated mounting boxes according to DIN VDE 0634 Part 1.<br />
Installable individual units: 9 units in EK design.<br />
If multiple installation units are used, then the number of connection<br />
options increases.<br />
Design<br />
service units consist of:<br />
– Floor covering protection frame and flushfloor frame<br />
including:<br />
– univseral fixing bracket,<br />
– hinged cover (captively located in the floor covering<br />
frame, lockable, automatic closing) including:<br />
- fushfloor lowerable or above-floor cord outlet with seal,<br />
- turn-lock fastener with automatic cover positioning,<br />
Cover structured with concentric circles - recesses and raised sections.<br />
Material<br />
Cover and protection frame made of die-cast aluminium, Tube made<br />
of polyamide.<br />
Function and design<br />
- The impressive surface - concentric circles, additionally emphasised by contrast<br />
varnishing of the recesses - removes the necessity of working the floor covering<br />
into the cover, which benefits both weight and handling.<br />
– The surface structure reliably prevents damage and scratching of the varnish,<br />
meaning that use is still possible in areas with high traffic loads, such as museums<br />
or ticket and exhibition halls.<br />
– The circular shape of the Service unit is independent of the direction and there<strong>for</strong>e<br />
combinable with all plan shapes.<br />
– All the materials used are extremely friction-resistant and are resistant against normal<br />
cleaning agents.<br />
Mounting boxes and cover plates, see Page 94ff.<br />
Minimum installation height <strong>for</strong> service unit: 75 mm.<br />
90
Installation of devices in <strong>underfloor</strong><br />
systems and raised floor <strong>for</strong> dry and<br />
wet-cleaned floors<br />
Service unit GRAF9<br />
Art. no. Code MOQ SI TI<br />
Flush floor service unit – GRAF9 –<br />
as described on the left, with floor covering protection<br />
frame, including fastening material.<br />
– Bright metallic surface with fine grooved structure, recesses<br />
painted in the colours:<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30862A6 GRAF9U7011 1 X 90<br />
30862F6 GRAF9U9011 1 X 90<br />
– Surface, natural-coloured aluminium,<br />
sand-blasted recesses, raised bright metallic<br />
areas, Tube in black or iron grey.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30864A6 GRAF9M/U7011 1 90<br />
30864F6 GRAF9M/U9011 1 90<br />
Flush floor service unit – GRAF9 –<br />
as described on the left, with floor covering application<br />
frame, including fastening material.<br />
– Bright metallic surface with fine grooved structure, recesses<br />
painted in the colours:<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30861A6 GRAFA9U7011 1 90<br />
30861F6 GRAFA9U9011 1 90<br />
– Surface, natural-coloured aluminium,<br />
sand-blasted recesses, raised bright metallic<br />
areas, Tube in black or iron grey.<br />
Iron grey, RAL 7011<br />
Graphite black, RAL 9011<br />
30863A6 GRAFA9M/U7011 1 90<br />
30863F6 GRAFA9M/U9011 1 90<br />
Ladders – GTGRAF9 –<br />
to accept up to three mounting boxes GB3<br />
beneath the GRAF9 unit.<br />
30877E GTGRAF9 1 –<br />
Mounting cover - DUG350-2R9SL -<br />
<strong>for</strong> installation of a GRAF9 in UZD350-2 <strong>for</strong> high traffic loads.<br />
With four adjustable supports to accept the live load.<br />
Levelling screws with locknut.<br />
Service units<br />
Levelling area in mm:<br />
75 + 35<br />
100 + 40<br />
130 + 40<br />
DUG350-2L..<br />
30341AA ..R9SL75/110 1 –<br />
30341AB ..R9SL100/140 1 –<br />
30341AC ..R9SL130/170 1 –<br />
91
Underfloor device installation<br />
GB2 - device installation<br />
with power sockets of type Module45<br />
Total length of cover plates must be 165 mm.<br />
Art. no. Code MOQ SI TI<br />
L<br />
B<br />
Mounting box – GB2 –<br />
“empty”, suitable <strong>for</strong> the installation of two individual<br />
installation units, with two strain relief devices <strong>for</strong><br />
incoming and outgoing conductors.<br />
Dimensions: W x D x L in mm: 76 x 39 x 165.<br />
30354A GB2 1 X –<br />
T<br />
Mounting box cover plates<br />
<strong>for</strong> blanking cover of GB2.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
L<br />
– GB2/3P01 –<br />
L = 61 mm<br />
30324A GB2/3P01 1 X –<br />
L<br />
– GB2P01 –<br />
L = 82.5 mm<br />
30325A GB2P01 1 X –<br />
L<br />
Mounting box cover plates<br />
<strong>for</strong> GB2 mounting boxes, <strong>for</strong> the installation of an Ackermann<br />
protection contact socket.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
L<br />
L<br />
L<br />
– GB2/3P3 –<br />
For the installation of a 1x protection contact socket.<br />
L = 61 mm<br />
– GB2P2 –<br />
For the installation of a 1x protection contact socket.<br />
L = 82.5 mm<br />
– GB2/3P4 –<br />
For the installation of a 2x protection contact socket.<br />
L = 104 mm<br />
– GB2P3 –<br />
For the installation of a 3x protection contact socket.<br />
L = 165 mm<br />
30324C GB2/3P3 1 X –<br />
30325C GB2P2 1 X –<br />
30324D GB2/3P4 1 X –<br />
30325D GB2P3 1 X –<br />
Mounting box partition – GB2/3TW –<br />
made of polyamide.<br />
30357A GB2/3TW 1 X –<br />
Label panel – BF1 –<br />
<strong>for</strong> attaching the mounting box cover plates.<br />
30330A BF1 1 X –<br />
Service units<br />
Strain relief – ZE2/3 –<br />
made of polyamide. For insertion in the mounting box<br />
cover plates or in the mounting boxes GB2 and GB3.<br />
Blank slot cover – LP45 –<br />
blanking cover of a square installation opening in an accessory<br />
cover plate.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
30359AV ZE2/3 10 X –<br />
30324E LP45 1 X –<br />
Mounting box insert – GBES –<br />
<strong>for</strong> the installation of a 1x power socket, type Module45.<br />
Insertion depth: 70 mm<br />
30358A GBES 1 X –<br />
1-g power socket, type Module45, 2-pin – S31 –<br />
16A/250V ~ , VDE type<br />
Direction of insertion 33°.<br />
Cream white<br />
Orange<br />
Red<br />
35901AB S31CW 1 X –<br />
35901AR S31OR 1 X –<br />
35901AU S31RT 1 –<br />
2-g power socket, type Module45, 2-pin – S32 –<br />
16A/250V ~ , VDE type<br />
Direction of insertion 33°.<br />
Cream white<br />
Orange<br />
Red<br />
35901BB S32CW 1 X –<br />
35901BR S32OR 1 X –<br />
35901BU S32RT 1 –<br />
3-g power socket, type Module45, 2-pin – S33 –<br />
16A/250V ~ , VDE type<br />
Direction of insertion 33°.<br />
Cream white<br />
Orange<br />
Red<br />
35901CB S33CW 1 X –<br />
35901CR S33OR 1 X –<br />
35901CU S33RT 1 –<br />
92
Underfloor device installation<br />
GB2 - device installation<br />
For installation of devices with<br />
support ring/support clip<br />
Total length of cover plates must be 165 mm.<br />
Art. no. Code MOQ SI TI<br />
L<br />
B<br />
Mounting box – GB2 –<br />
“empty”, suitable <strong>for</strong> the installation of two individual<br />
installation units, with two strain relief devices <strong>for</strong><br />
incoming and outgoing conductors.<br />
Dimensions: W x D x L in mm: 76 x 39 x 165.<br />
30354A GB2 1 X –<br />
T<br />
L<br />
Mounting box cover plates<br />
<strong>for</strong> GB2 mounting boxs, <strong>for</strong> blank cover.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
– GB2/3P01 –<br />
L = 61mm<br />
30324A GB2/3P01 1 X –<br />
L<br />
– GB2P01 –<br />
L = 82.5 mm<br />
Mounting box cover plates<br />
<strong>for</strong> GB2 mounting boxs, <strong>for</strong> the installation<br />
of a unit with support clip (EK version).<br />
Material: Polyamide, Graphite blackRAL 9011.<br />
30325A GB2P01 1 X –<br />
L<br />
– GB2/3P1 –<br />
L=61mm<br />
30324B GB2/3P1 1 X –<br />
L<br />
– GB2P1 –<br />
L=825 mm<br />
(also suitable <strong>for</strong> installation unit with<br />
support ring, EKR version).<br />
30325B GB2P1 1 X –<br />
L<br />
– GB2/3P5 –<br />
with 60 mm screw fastening track.<br />
Installation opening in mm: 47 x 47.<br />
L=104 mm<br />
30324G GB2/3P5 1 X –<br />
Mounting box partition – GB2/3TW –<br />
made of polyamide.<br />
30357A GB2/3TW 1 X –<br />
Label panel – BF1 –<br />
<strong>for</strong> attaching to mounting box cover plates.<br />
30330A BF1 1 X –<br />
Service units<br />
Strain relief – ZE2/3 –<br />
For insertion in the mounting box cover plates or in the<br />
mounting boxs GB2 and GB3.<br />
Made of polyamide.<br />
30359AV ZE2/3 10 X –<br />
Blank slot cover – LP/R45 –<br />
as blanking lock of a round installation opening in a mounting<br />
box cover plate.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
30324F LP/R 1 X –<br />
93
Underfloor device installation<br />
GB3 - device installation<br />
with power sockets of type Module45<br />
Total length of cover plates must be 208 mm.<br />
Art. no. Code MOQ SI TI<br />
L<br />
B<br />
Mounting box – GB3 –<br />
“empty”, suitable <strong>for</strong> the installation of three individual<br />
installation units, with two strain relief devices <strong>for</strong><br />
incoming and outgoing conductors.<br />
Dimensions: W x D x L in mm: 76 x 39 x 208.<br />
30355A GB3 1 X –<br />
T<br />
L<br />
L<br />
L<br />
Mounting box cover plates<br />
<strong>for</strong> blanking cover of GB3.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
– GB2/3P01 –<br />
L = 61mm<br />
– GB2/3P01 –<br />
L = 104 mm<br />
– GB2P01 –<br />
L = 147mm<br />
30324A GB2/3P01 1 X –<br />
30326A GB2/3P02 1 X –<br />
30326B GB3P01 1 X –<br />
L<br />
Mounting box cover plates<br />
<strong>for</strong> GB3 mounting boxs, <strong>for</strong> the installation of an Ackermann<br />
protection contact socket.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
– GB2/3P3 –<br />
<strong>for</strong> the installation of a 1-g power socket.<br />
L = 61mm<br />
30324C GB2/3P3 1 X –<br />
L<br />
– GB2/3P4 –<br />
<strong>for</strong> the installation of a 2-g power socket.<br />
L = 104 mm<br />
30324D GB2/3P4 1 X –<br />
L<br />
– GB2P3 –<br />
<strong>for</strong> the installation of a 3-g power socket.<br />
L = 147 mm<br />
30326F GB3P3 1 X –<br />
Mounting box partition – GB2/3TW –<br />
made of polyamide.<br />
Label panel – BF1 –<br />
<strong>for</strong> attaching to mounting box cover plates.<br />
30357A GB2/3TW 1 X –<br />
30330A BF1 1 X –<br />
Service units<br />
Strain relief – ZE2/3 –<br />
<strong>for</strong> insertion in the mounting box, cover plates or in the mounting<br />
boxes GB2 and GB3. Made of polyamide.<br />
Blank slot cover – LP45 –<br />
blanking cover of a square installation opening in an accessory<br />
cover plate.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
30359AV ZE2/3 10 X –<br />
30324E LP45 1 X –<br />
Mounting box insert – GBES –<br />
<strong>for</strong> the installation of a 1-g power socket, type Module45.<br />
Insertion depth: 70 mm,<br />
1-g power socket, type Module45, 2-pin – S31 –<br />
16A/250V ~ , VDE type<br />
Direction of insertion 33°.<br />
Cream white<br />
Orange<br />
Red<br />
30358A GBES 1 X<br />
35901AB S31CW 1 X –<br />
35901AR S31OR 1 X –<br />
35901AU S31RT 1 –<br />
2-g power socket, type Module45, 2-pin – S32 –<br />
16A/250V ~ , VDE type<br />
Direction of insertion 33°.<br />
Cream white<br />
Orange<br />
Red<br />
35901BB S32CW 1 X –<br />
35901BR S32OR 1 X –<br />
35901BU S32RT 1 –<br />
3-g power socket, type Module45, 2-pin – S33 –<br />
16A/250V ~ , VDE type<br />
Direction of insertion 33°.<br />
Cream white<br />
Orange<br />
Red<br />
35901CB S33CW 1 X –<br />
35901CR S33OR 1 X –<br />
35901CU S33RT 1 –<br />
94
Underfloor device installation<br />
GB3 - device installation<br />
For installation of devices with<br />
support ring/support clip<br />
Total length of cover plates must be 208 mm.<br />
Art. no. Code MOQ SI TI<br />
L<br />
B<br />
Mounting box – GB3 –<br />
“empty”, suitable <strong>for</strong> the installation of three individual<br />
installation units, with two strain relief devices <strong>for</strong><br />
incoming and outgoing conductors.<br />
Dimensions: W x D x L in mm: 76 x 39 x 208.<br />
30355A GB3 1 X –<br />
T<br />
L<br />
L<br />
L<br />
Mounting box cover plates:<br />
<strong>for</strong> GB3 mounting boxs, <strong>for</strong> blank cover.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
– GB2/3P01 –<br />
L = 61 mm<br />
– GB2/3P01 –<br />
L = 104 mm<br />
– GB2P01 –<br />
L = 147 mm<br />
30324A GB2/3P01 1 X –<br />
30326A GB2/3P02 1 X –<br />
30326B GB3P01 1 X –<br />
Mounting box cover plates:<br />
<strong>for</strong> GB3 mounting boxs, <strong>for</strong> the installation of a unit with EKR<br />
support ring or EK support clip.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
L<br />
– GB2/3P1 – (EK)<br />
L=61 mm<br />
30324B GB2/3P1 1 X –<br />
L<br />
– GB2/3P2 – (EK und EKR)<br />
L=104 mm<br />
30326C GB2/3P2 1 X –<br />
L<br />
– GB2/3P5 – (EKR)<br />
with 60 mm screw fastening track.<br />
Installation opening in mm: 47 x 47.<br />
L=104 mm<br />
30324G GB2/3P5 1 X –<br />
L<br />
– GB3P1 – (EK)<br />
L=147 mm<br />
30326D GB3P1 1 X –<br />
L<br />
– GB3P2 – (EK)<br />
L=208 mm<br />
Mounting box partition – GB2/3TW –<br />
made of polyamide.<br />
30326E GB3P2 1 X –<br />
30357A GB2/3TW 1 X –<br />
Service units<br />
Label panel – BF1 –<br />
<strong>for</strong> attaching to mounting box cover plates.<br />
30330A BF1 1 X –<br />
Strain relief – ZE2/3 –<br />
made of polyamide.<br />
For insertion in the mounting box cover plates or in the mounting<br />
boxs GB2 and GB3.<br />
30359AV ZE2/3 10 X –<br />
Blank slot cover – LP/R45 –<br />
as blanking lock of a round installation opening in a mounting<br />
box cover plate.<br />
Material: Polyamide, Graphite black RAL 9011.<br />
30324F LP/R 1 X –<br />
95
Installation of devices in <strong>underfloor</strong> systems<br />
Mounting of connection modules <strong>for</strong> data systems<br />
Art. no. Code MOQ SI TI<br />
Mounting frame<br />
to accept two or three support plates and one<br />
strain relief device. Material: Sheet steel; RAL 9011.<br />
– MTU2 –<br />
to accept two support plates. Installation instead of a GB2<br />
mounting box. Length in mm: 165.<br />
– MTU3 –<br />
to accept three support plates. Installation instead of a GB3<br />
mounting box. Length in mm: 208.<br />
Strain relief - MTUZE -<br />
<strong>for</strong> strain relief of incoming<br />
connection conductors.<br />
Material: Sheet steel; RAL 9011.<br />
30384A MTU2 1 –<br />
30384B MTU3 1 –<br />
30384C MTUZE 1 –<br />
Support plate – MTM –<br />
to accept two or three connection sockets <strong>for</strong> data, audio or<br />
video systems.<br />
Material: V2A.<br />
Installation opening:<br />
2 x Hole pattern Type A<br />
3 x Hole pattern Type A<br />
2 x Hole pattern Type B<br />
3 x Hole pattern Type B<br />
2 x Hole pattern Type C<br />
3 x Hole pattern Type C<br />
1 x Hole pattern Type D<br />
3 x Hole pattern Type E<br />
2 x Hole pattern Type F<br />
2 x Hole pattern Type G<br />
2 x Hole pattern Type H<br />
1 x Hole pattern Type K<br />
2 x Hole pattern Type K<br />
2 x Hole pattern Type L<br />
2 x Hole pattern Type M<br />
2 x Hole pattern Type N<br />
Blank<br />
30385A2 MTM2A 1<br />
30385A3 MTM3A 1<br />
30385B2 MTM2B 1<br />
30385B3 MTM3B 1<br />
30385C2 MTM2C 1<br />
30385C3 MTM3C 1<br />
30385D MTM1D 1<br />
30385E3 MTM3E 1<br />
30385F2 MTM2F 1<br />
30385G2 MTM2G 1<br />
30385H2 MTM2H 1<br />
30385K MTM1K 1<br />
30385K2 MTM2K 1<br />
30385L2 MTM2L 1<br />
30385M2 MTM2M 1<br />
30385N2 MTM2N 1<br />
30385P MTM09 1<br />
Service units<br />
Technical data<br />
Required<br />
insertion depth<br />
reference list of current connection sockets and<br />
of modular connection systems<br />
Type A 80 mm 2x Brand-Rex, GG45, Siemon CAT6, SETEC CAT6<br />
Type A 80 mm 3x MTRJ, AMP TYCO CAT6, GG45<br />
Type B 80 mm BTR E-DAT, Dätwyler<br />
Type C 100 mm Siemon TERA, RDM CAT6<br />
Type D 80 mm DSUB9, VGA<br />
Type E 80 mm Corning<br />
Type F 80 mm Avaya MGS400<br />
Type G 80 mm Kerpen E-Line<br />
Type H 90 mm 3M<br />
Type K 100 mm XLR SPEAK-ON Type D<br />
Type L 100 mm SCDuplex fibre optic cable<br />
Type M 80 mm ST fibre-optic cable<br />
Type N 80 mm Krone module<br />
Mounting frame<br />
<strong>for</strong> accepting two or three data modules of type ACO<br />
(only with INST KIT UF60 from AMP Tyco).<br />
Material: V2A.<br />
– MT2/2ACO –<br />
<strong>for</strong> two ACO data modules, length in mm: 165.<br />
– MT3/3ACO –<br />
<strong>for</strong> three ACO data modules, length in mm: 208.<br />
30366J MT2/2ACO 1 –<br />
30366K MT3/3ACO 1 –<br />
96
Installation of devices in <strong>underfloor</strong> systems<br />
Mounting trays and cover plates <strong>for</strong> installation in<br />
service outlets and cassettes<br />
Art. no. Code MOQ SI TI<br />
Mounting tray – MT2BS2. –<br />
<strong>for</strong> service unit GES2.<br />
<strong>for</strong> 2gang MK socket, switched<br />
<strong>for</strong> 4 x RJ45 LJU 6C<br />
30883 E MT2BS2SS0 1<br />
30883 F MT2BS2CO 1<br />
Mounting tray – MT2BS. –<br />
<strong>for</strong> service units and height adjustable cassettes.<br />
GES4, GESR4, cassettes R4 and RKN4<br />
GES6<br />
GESR7 and cassettes R7<br />
GES9, GESR9, cassettes R9 and RKN9<br />
30883 C MT2BS2/4 1<br />
30883 A MT2BS2/6 1<br />
30883 D MT2BS2/7 1<br />
30883 BA MT2BS2/9 1<br />
Mounting plate – APMT. –<br />
<strong>for</strong> installation of BS devices in mounting trays.<br />
1.2mm galvanized steel, coated.<br />
Dimensions LxW in mm: 163 x 72.5.<br />
Blank<br />
<strong>for</strong> 4 x RJ45 LJU 6C<br />
2gang MK socket, switched<br />
60501 UA APMT2/0 5<br />
60501 VA APMT2/1 5<br />
60501 WA APMT2/2 5<br />
Other mounting plates on request.<br />
Simply “gripping” -<br />
Unit installation in<br />
<strong>underfloor</strong> areas<br />
Your benefits<br />
+ Screwless mounting of the<br />
sockets in cover plates<br />
+ Screwless conductor connection<br />
of the sockets<br />
Service units<br />
+ Simple mounting of installation units<br />
with support ring/clip<br />
+ Screwless strain relief<br />
+ Covers lock<br />
onto the mounting box without screws<br />
+ Increased mounting space in the<br />
mounting box<br />
= Simple & time-saving<br />
electrical installation<br />
97
A A<br />
A<br />
UZD<br />
190<br />
S2/...../ 2000 mm<br />
coupler (VL)<br />
ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-ACKER ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEU<br />
2400<br />
UZD<br />
250<br />
140 mm<br />
98
Planning Data<br />
EÜK – screed-covered<br />
duct system from Page 100 - 103<br />
OKA/T –flush-floor<br />
trunking system from Page 104 - 105<br />
Service units GES/GRAF9 from Page 106 - 109<br />
50<br />
ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-ACKER<br />
m<br />
99
System-specific<br />
planning and installation instructions<br />
EÜK - Screed-covered duct system<br />
Laying the <strong>underfloor</strong> duct<br />
The <strong>underfloor</strong> ducts must be laid on the bare concrete of the building and then<br />
covered with the screed.<br />
Danger<br />
If there is insufficient screed covering of the ducts, then the screed may tear<br />
when there is a load. Comply with the minimum screed covering of the ducts<br />
(see VOB Part C/DIN 18353 and DIN 18560 “Floor screeds in<br />
building construction”).<br />
Use of <strong>underfloor</strong> boxes<br />
Two types of <strong>underfloor</strong> boxes are used: <strong>underfloor</strong> junction and branch box UZD<br />
and empty <strong>underfloor</strong> box UGD. Underfloor junction and branch boxes are placed<br />
in the duct section ...<br />
... to simplify conductor pulling (at a distance of approx. 8 m).<br />
... if there is a change in direction or junctions.<br />
Empty <strong>underfloor</strong> boxes are used to install flush-floor installation units, GRAF 9<br />
variable height service units or height adjustable cassettes.<br />
The decision whether an <strong>underfloor</strong> box is used as a junction or branch box or an<br />
empty <strong>underfloor</strong> box should be taken be<strong>for</strong>e applying the floor covering.<br />
We advise the general use of empty <strong>underfloor</strong> boxes, which can be equipped<br />
with service units GES or inserts ZES of the same size. Connection expansions by<br />
replacing service units GES are always possible with the appropriate box size.<br />
Connection system<br />
Electrical devices are installed in:<br />
- GES service units or RKS/RKRS/RKSN cassettes<br />
– Variable height GRAF9 or SH(F) service units or RKF/RKRF/RKFN cassettes<br />
– Telitank above-floor installation units.<br />
Expansion of the connection at a later date is possible by drilling the <strong>underfloor</strong><br />
ducts. Units are then installed under an SH(F) protective cover or in a Telitank.<br />
Calculation of the effective cable length<br />
When planning and setting up <strong>underfloor</strong> electrical installation ducts, take the<br />
following deductions into account:<br />
Deduction dimension “A” in mm<br />
Article Short code “A”<br />
Vertical bend VK... 200<br />
Empty <strong>underfloor</strong> sockets UGD 190/... 220<br />
UGD 250-2/... 280<br />
UGD 350-2/... 380<br />
Connecting shackle VL... 10<br />
Underfloor draw and junction box UZD 190 220<br />
UZD 250-2 280<br />
UZD 350-2 380<br />
Example<br />
Socket alignment dimension =<br />
Distance from socket centre to socket centre = 2,400 mm<br />
minus A/2 of UZD 190 = 110 mm<br />
minus A/2 of UZD 250-2 = 140 mm<br />
minus swelling width of the VL = 10 mm<br />
Effective duct length = 2,140 mm<br />
c<br />
EÜK – <strong>underfloor</strong> installation ducting system<br />
e<br />
b<br />
a<br />
b<br />
f<br />
h<br />
i<br />
j<br />
g<br />
a) <strong>underfloor</strong> installation duct<br />
b) coupler<br />
c) vertical bend<br />
d) empty <strong>underfloor</strong> box<br />
e) stacking frame<br />
f) flushfloor service unit GES 6<br />
g) above-floor installation unit T8NL<br />
h) bare concrete floor<br />
i) screed structure<br />
j) floor covering<br />
d<br />
Planning data<br />
a<br />
b<br />
a<br />
b<br />
A A<br />
A<br />
UZD<br />
190<br />
S2/...../ 2000 mm<br />
coupler (VL)<br />
ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-ACKER ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEU<br />
2400<br />
UZD<br />
250<br />
140 mm<br />
ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-ACKER<br />
Dimensions “A“ should be considered<br />
when calculating the duct length.<br />
100
System-specific<br />
planning and installation instructions<br />
EÜK - Screed-covered duct system<br />
Duct direction corrections<br />
Small duct direction corrections (up to 7°) in the course of the cable duct can be<br />
compensated in the insertion openings of the <strong>underfloor</strong> sockets without adjustment<br />
cuts (see Fig. “A”).<br />
Sloping duct insertions<br />
Sloping duct insertions (> 7°) can be created using appropriate adjustment cuts<br />
(see Fig. “B“) depending on the box size and insertion opening<br />
(see table below).<br />
Fig. “A“<br />
Fig. “B“<br />
RK<br />
SE<br />
SE<br />
RK<br />
SE<br />
SE<br />
Nominal sokket<br />
size<br />
350 250 190<br />
Nominal size<br />
Nominal duct size<br />
of the socket<br />
insertion<br />
opening 190 250 350<br />
R K S E R K S E R K S E<br />
MANN-EÜK-VDE-ÖVE-KEMA-KEUR- ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-<br />
SD-3500<br />
IMPEX<br />
ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-ACKERMANN-EÜK-VDE-ÖVE-KEMA<br />
ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-<br />
System-specific<br />
planning and installation instructions<br />
EÜK – Screed-covered duct system<br />
Installation instructions<br />
1. Use the duct layout plan to select a fixed<br />
starting point <strong>for</strong> the installation, <strong>for</strong> example a<br />
junction box.<br />
2. Tie two guide lines (approx 150 mm above the raw<br />
concrete) at 90º to each other, ensuring that they<br />
match the duct layout plan.<br />
3. Position the first junction box centrally below<br />
the intersection of the guide lines and level<br />
to required screed depth. (boxes supplied<br />
adjusted to 70 mm).<br />
ACKERMANN-EÜK-VDE- ÖVE- KEMA-KEUR-A<br />
- EÜK- VDE- ÖVE- KEMA- KEU<br />
ACKERMANN-EÜK-VDE-<br />
ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR -<br />
ACKERMANN - EÜK- VDE-ÖVE<br />
A- KEUR - ACKERMANN-E<br />
ACKERMANN-EÜK-VD<br />
4. Lay duct / trunking sections to reflect the layout<br />
plan. Ensure ducting compartments are aligned as<br />
indicated by the continuous marking on the top of<br />
the duct.<br />
5. Open the pre-punched side walls of the <strong>underfloor</strong><br />
box and insert the duct as far as it will go.<br />
6. Fasten the <strong>underfloor</strong> / junction box and<br />
readjust to required screed depth level.<br />
Planning data<br />
ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-ACKERMANN-EÜK-VDE-ÖVE-KEMA-KEUR-<br />
ACKERMANN-EÜK-VDE-<br />
ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR -ACKER<br />
ACKERMANN-EÜK-VD<br />
7. Fasten the duct sections at coupling devices to the<br />
concrete.<br />
8. Important: Ensure external duct partition markings<br />
are aligned.<br />
9. Attach an earth continuity connector at all<br />
duct couplings or joints.<br />
102
System-specific<br />
planning and installation instructions<br />
EÜK – Screed-covered duct system<br />
Installation instructions<br />
3<br />
EÜK - VDE - ÖVE - KEMA - KEUR - A ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK -<br />
ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - A ACKERMANN - EÜK - VDE - ÖVE - KEMA - KEUR - ACKERMANN - EÜK -<br />
1<br />
2<br />
10. The minimum screed depth is 70 mm.<br />
Sockets can be adjusted to the required<br />
depth (max. 120 mm) using the levelling<br />
screws.<br />
11. By means of stacking frame the height of the floorbox<br />
can be extended by +35 mm. Stacking frame<br />
has to be mounted on top of the floor box.<br />
12. Underfloor outlet - US 80 - can be levelled to top<br />
screed level with help of adjustment rings<br />
(15 mm or 24 mm). Mounting sequence: unscrew<br />
balancing ring (1) + (2), add adjustment ring to<br />
balancing ring, screw levelled balancing ring into<br />
outlet (3).<br />
Notes on using screed-covered duct<br />
systems in screed<br />
Screed<br />
UZD / UGD<br />
Duct<br />
Insulation layer (cover)<br />
Insulation<br />
Concrete<br />
Screed work<br />
As the duct system or part of the duct system serves as a binding pull<br />
gauge <strong>for</strong> the screed, the levelling must be agreed with the construction<br />
company.<br />
When applying the screed, the person laying the screed must<br />
carefully prepare, seal and pull away the screed around the junction<br />
boxes.<br />
Divider strips must not be used as the junction boxes can only achieve the<br />
robustness specified if they are joined directly to the screed. Using divider<br />
strips can damage the flooring.<br />
Important:<br />
Screed can be damaged by cracks. Do not put strain on adjacent systems<br />
and system components that are joined to the screed be<strong>for</strong>e the screed has<br />
hardened.<br />
Care should be taken to ensure that the sealing process does not create<br />
hollow areas between the components and the screed. Possible openings<br />
can be found, <strong>for</strong> example, at joints between ducts and connection lugs and<br />
vertical bends or to UZD/UGD <strong>underfloor</strong> sockets. The top connections, like<br />
the assembly protection cover and the assembly or blanking covers should<br />
be sealed using appropriate means.<br />
Aggressive screed (e.g. magnesia screed)<br />
With this screed, all metallic components which come into contact with the<br />
screed should be protected with an accredited corrosion protection agent<br />
based on epoxy resin (two coats).<br />
See also VOB Part C (ATV) DIN 18353, Paragraph 3.1.8.<br />
Use in poured asphalt<br />
Essentially, there are no restrictions with respect to the use of the<br />
installation duct system in poured asphalt.<br />
Planning data<br />
Screeds, general.<br />
Under some circumstances, chemical or thermal strain can occur which<br />
means taking special additional measures to protect the installed systems<br />
(see, <strong>for</strong> example, VOB Part C (ATV), DIN 18353, Paragraph 3.1.8).<br />
Use in poured screeds<br />
When using screed-covered duct system in poured screeds, all the<br />
openings in the duct system must be sealed using appropriate means (e.g.<br />
using adhesive tape).<br />
The following is deemed as the most practical approach to using the system<br />
in poured asphalt:<br />
a) Under no circumstances must the screed-covered ducts come into direct<br />
contact with the poured asphalt. The high installation temperature<br />
(approx. 250ºC) means that it is not impossible <strong>for</strong> metallic components to<br />
be de<strong>for</strong>med.<br />
b) The duct systems are laid on the bare concrete and fixed in accordance<br />
with the fitting instructions.<br />
c) The duct routes are protected against heat shock using an appropriate<br />
layer of insulation (e.g. Fasoperl sheets or bitumen-coated corrugated<br />
cardboard).<br />
d) The socket bodies do not require additional insulating strips.<br />
e) The poured asphalt is applied.<br />
103
System-specific<br />
planning and installation instructions<br />
Open, flushfloor trunking system – OKA/T<br />
S<br />
p<br />
O<br />
k<br />
guide line<br />
i<br />
1. Carry out marking of ”Main” and<br />
”Branch” trunking routes on floor slab as<br />
per layout drawing, taking a fixed reference<br />
point from any side of building.<br />
2. Lay out the prefabricated parts along routes<br />
marked; resp. assemble trunking sections with<br />
side profiles and cover plates lay out the sections<br />
along routes marked.<br />
3. Align trunking bases and join trunking<br />
sections with couplers.<br />
1.<br />
2.<br />
4. Insert slab bracket on side profiles at 800<br />
mm spacing, 6 on each standard trunking<br />
length.<br />
5. Optional:<br />
Fix levelling brackets to side profiles at 800 mm<br />
spacing, 6 on each standard trunking section.<br />
Pre-adjust and carry out general<br />
levelling of the trunking to final screed level.<br />
6. Secure trunking to floor slab with slab bracket<br />
or levelling brackets fixed to side profiles.<br />
N-11mm<br />
11mm<br />
Planning data<br />
7. Branches to be built at site. Trunking base<br />
and side profile has to be opened according<br />
to trunking width of branching<br />
unit. Trunking and branch unit are fixed<br />
with connecting angles in the side profiles.<br />
When “in-screed <strong>underfloor</strong> trunking<br />
EÜK” is used <strong>for</strong> branching, only the<br />
trunking base has to be opened.<br />
8. Form 90° bend as per layout drawing. Cut<br />
side wall of base trunking only on one side<br />
according to the width of trunking to be joined.<br />
Shorten inner side profile of branch trunking by<br />
11mm. Insert end cap, supplied with 90° angle<br />
set to close end of main trunking. Join main and<br />
branch trunking sections with coupler and coupling<br />
angle as shown.<br />
9. Optional:<br />
Carry out final levelling of the trunking.<br />
Caution! Do not walk over the trunking <strong>for</strong> further<br />
installation steps after final levelling!<br />
104
OKA<br />
OKU<br />
OKA<br />
OKU<br />
OKA<br />
OKU<br />
System-specific<br />
planning and installation instructions<br />
Open, flushfloor trunking system – OKA/T<br />
10. Optional:<br />
To be used in conjunction with levelling brakkets<br />
only. Insert screed anchors on side profiles<br />
and fix them by turning clockwise (at 800<br />
mm spacing, 6 on each standard trunking<br />
section).<br />
11. Optional:<br />
Cut levelling screws of fixing angles to 5 mm<br />
lower than top of side profile. (Use a tape to<br />
cover the top sides of side profiles to prevent ingress<br />
of screed into fixation holes.)<br />
12. Caution! Do not walk over trunking during<br />
screed work. Trunking may be used<br />
as a levelling plane.<br />
13. Earthing of trunking:<br />
All metallic parts of the trunking (base and<br />
side profiles) provide connection possibilities<br />
<strong>for</strong> the earth conductor clamp 8AWR (separate<br />
order no.).<br />
For fixed height trunking system, a smooth and levelled<br />
surface must have been prepared, onto<br />
which trunking system shall be installed.<br />
Arrange to provide ”Ribbon/Packing” screed below<br />
trunking profiles without leaving any pockets<br />
belows and secure base of trunking to floor slab at<br />
least at 600 mm spacing at holes provided at the<br />
base.<br />
Seal all openings and gaps with polythene sheets<br />
and/or masking tapes and/or silicon putty (to be<br />
supplied by installer). Provide rust preventive coat<br />
with zinc rich paint on all cut edges of trunking and<br />
components.<br />
Planning data<br />
105
System-specific<br />
planning and installation instructions<br />
GES/GRAF9 Service units<br />
Requirements <strong>for</strong> use in wet-cleaned floors<br />
DIN VDE 0634 Part 1 defines moisture protection <strong>for</strong> flushfloor and variable<br />
height service units as follows:<br />
a) The service unit must be protected against water levels of 10 mm on the<br />
floor surface (resistant both in the operational and non-operational states).<br />
b) Unclosed openings, such as cable outlets must have a minimum distance of<br />
30 mm to the floor surface (splash protection).<br />
GES flushfloor service units and<br />
GRAF9 variable height service unit<br />
Flushfloor service units GES can, in line with the standard, only be used in dry<br />
rooms with dry-cleaned floors; by contrast GRAF9 variable - height service<br />
units can also be used in dry rooms with wet-cleaned floors. Both meet the<br />
relevant DIN VDE regulations and thus the level of safety required<br />
by the European Community. They are installed in the covers of <strong>underfloor</strong><br />
boxes and <strong>underfloor</strong> trunkings of the appropriate<br />
<strong>underfloor</strong> systems.<br />
Accessories <strong>for</strong> power, telecommunications and data systems are mounted in<br />
separate mounting boxes or parts of such boxes made of insulating material.<br />
The use of mounting boxes made of insulating material provides the greatest<br />
possible safety against the transfer of error voltages from the power connection<br />
area to the telecommunications components or neighbouring metallic parts of<br />
the <strong>underfloor</strong> box or the <strong>underfloor</strong> trunking. All the incoming and outgoing<br />
connection conductors must have strain relief. The mounting boxes can be<br />
lowered into the interior of the <strong>underfloor</strong> box the <strong>underfloor</strong> trunking. The plug<br />
height (measure without contact pins) of the connected consumers may there<strong>for</strong>e<br />
vary between 27 and 47 mm.<br />
With a plug height of 47 mm, the screed height must be at least 80 mm. The<br />
mounting boxes can be lowered using notched guides. Flush-floor service units<br />
GES can be equipped with several (differing) mounting boxes, depending on<br />
the design. Each mounting box can be inserted, lowered and removed separately.<br />
SH(F) variable height service units<br />
SH variable height service units can, in accordance with the standard, only be<br />
used in dry rooms with dry-cleaned floors; however SHF variable height<br />
service units can also be used in dry rooms with wet-cleaned floors. Both meet<br />
the relevant VDE standards and thus the level of safety required by<br />
the European Community.<br />
A single accessory can be installed inside; the device and the connecting plug<br />
are protected by a hinged cover. The hinged cover has a rotating bearing so<br />
that the cord outlet opening can always be turned to the best possible position<br />
towards the consumer.<br />
Mounting of flushfloor service units (GES)<br />
1. During installation, it is assumed that floor covering has already been applied<br />
to the mounting covers and that the installation openings have been cut open.<br />
The mounting procedure <strong>for</strong> installing the service units is more or less identical<br />
<strong>for</strong> all sizes. There<strong>for</strong>e, the following section will describe the mounting procedure<br />
<strong>for</strong> the GES4 service unit as a representative <strong>for</strong> all the service units.<br />
We will draw your attention to items which deviate from the mounting procedure<br />
<strong>for</strong> the GES4.<br />
2. To fix the GES4 service unit in mounting covers of empty <strong>underfloor</strong> boxes or<br />
trunkings, you must first remove the hinged cover (1). To do this, move it to the<br />
vertical position and pull the left-hand side of the cover out of its bearing.<br />
3. Then insert the carpet protection frame (6) of the service unit into the<br />
mounting opening (4) and fasten it using the corner screws, which affect the<br />
clamping angle. In doing so, ensure that the clamping brackets (2) are securely<br />
located under the mounting cover (3).<br />
3<br />
2<br />
2<br />
1<br />
6<br />
4<br />
Planning data<br />
106
System-specific<br />
planning and installation instructions<br />
GES Service units<br />
4<br />
4<br />
7<br />
6<br />
5<br />
3<br />
3<br />
2<br />
2<br />
4. Prepare mounting box <strong>for</strong> incoming cabling.<br />
Install mounting box inside the frame (7).<br />
5. Installation of accessories with mounting bracket or<br />
mounting ring<br />
– connect cabling with accessory (3)<br />
– clips accessory under the cover plate (4)<br />
– install strain relief in cover plate and relieve<br />
the cable<br />
– Clips cover plate onto mounting box<br />
– screw central cover plate (5) onto accessory.<br />
5. Installation of Ackermann power sockets<br />
– install power socket (4) into cover plate (3)<br />
– connect cabling with power socket<br />
– install strain relief in cover plate and relieve the cable<br />
– Clips cover plate onto mounting box.<br />
12<br />
10<br />
1<br />
13<br />
14<br />
1<br />
6<br />
5<br />
6. Accessories of different voltages in one<br />
mounting box shall be segregated by a divider<br />
(12).<br />
7. Apply lid (1) to frame (6). Install lid according to<br />
following sequence:<br />
– Place nock at right side into corresponding hole in<br />
the frame<br />
– Push left side of lid until the left side nock reaches<br />
end position.<br />
8. The hinged cover (1) has a captive cord outlet (14).<br />
The hinged cover can be lifted up using the lowerable<br />
grip (13). Firstly, the cord outlet swivels up and<br />
engages. If the Service unit is not used, then fold<br />
the cord outlet back in when closing the cover<br />
(cover also engages).<br />
17<br />
1<br />
16<br />
15<br />
18<br />
Planning data<br />
GESR 4<br />
9. Mounting of the “round” service units<br />
The mounting procedure corresponds to that of<br />
the GES 4 Service unit. However it has the following<br />
differences:<br />
a) Fastening of the GESR4 or<br />
GESR(A)7 Service unit:<br />
when the hinged cover is open, all the fastening<br />
screws are accessible.<br />
b) Fastening the GESR9 Service unit:<br />
of the six fastening screws, four can be reached<br />
immediately<br />
when the hinged cover is open,<br />
while the two in the hinge area become accessible<br />
when the hinged cover is pulled <strong>for</strong>wards towards<br />
the cord inlet.<br />
c) GESR4, GESR(A)7, GESR9:<br />
Removal of lid of circular outlets Open lid (1) and<br />
overstretch it by more than 90°. Hinge (15) will<br />
release automatically and lid can be layed down.<br />
For complete removal of lid, use a screwdriver to<br />
release the hinge from the frame. Closing the lid:<br />
Simply close the lid and press on top of it until reaching<br />
the end position (“click”).<br />
107
System-specific<br />
planning and installation instructions<br />
GRAF9 Service units<br />
service outlet<br />
<strong>underfloor</strong> box<br />
fixing<br />
clip<br />
mounting tray<br />
1. Screw the GRAF9 and the mounting box support<br />
together.<br />
2. Insert the service unit in the <strong>underfloor</strong> box.<br />
There are eight fixing brackets included with the<br />
service unit.<br />
sealing compound sealing compound distance frame<br />
3. Seal the service unit against any moisture from the<br />
floor covering. For this, use suitable materials (e.g.<br />
permanently elastic sealing compound).<br />
In the case of service units with a protective floor covering<br />
frame, ensure that the frame covers the whole of<br />
the appropriate area.<br />
3a. With flush-floor installation with a floor covering application<br />
frame, the opening in the floor covering has a<br />
diameter of 328 mm. This means that there will be a<br />
3 mm gap around the service unit <strong>for</strong> later sealing.<br />
The application frame must be flush with the top<br />
edge of the floor covering. Walk-over protection must<br />
be guaranteed, i.e. the service unit must not be pushed<br />
downwards by traffic loads.<br />
3b. When using the DR spacer rings, place two<br />
rings around each service unit so that the<br />
floor covering application frame is flat against<br />
it. Fill the space between the application<br />
frame and the opening in the floor covering<br />
(ø 328 mm) with suitable<br />
sealing material.<br />
In<strong>for</strong>mation<br />
4. Connecting the devices:<br />
open the rotary lock using a screwdriver or coin and<br />
the cover of the service unit will spring up.<br />
Open the service unit cover, push out the Tube from<br />
below and lock it into the operational position by turning<br />
it to the left.<br />
Open the hinged cover of the Tube, pass the conductors<br />
through and connect the plugs to the devices.<br />
Close the cover, ensuring that the approved plug<br />
heights are not exceeded and no conductors are<br />
crushed.<br />
The cover engages automatically when lightly pushed.<br />
Arrange the conductors and close the hinged cover of<br />
the Tube.<br />
5. Remove the terminal connection:<br />
open the rotary lock with a screwdriver or a coin and<br />
the cover of the service unit will spring up.<br />
Open the cover of the Service unit.<br />
Remove the conductors, close the hinged cover of<br />
the Tube.<br />
Unlock the Tube by turning it to the right.<br />
Close the service unit cover and push in the Tube by<br />
applying slight pressure with your foot.<br />
The cover and the Tube must be flush against the<br />
frame to ensure moisture protection.<br />
Protective measure<br />
The service unit must be included in one of the<br />
protective measures against indirect contact.<br />
According to DIN VDE 0100, the effectiveness<br />
of the protective measure must be tested and<br />
proved when an electrical system is installed.<br />
108
System-specific<br />
planning and installation instructions<br />
In<strong>for</strong>mation on mounting<br />
devices in the US80 single outlet<br />
closed<br />
open 3<br />
2<br />
1<br />
Be<strong>for</strong>e mounting the device in the single outlet, turn the<br />
mounting ring of the single oulet to the required installation<br />
depth of the installation unit (lowest position). To do<br />
this, slacken the clamping screw of the mounting ring,<br />
turn the ring to the required position and retighten it.<br />
Connection of Modude45 power sockets<br />
- lock the power socket (2) from above into the<br />
appropriate cover plate (1)<br />
- connect the socket.<br />
- screw the cover plate (1) tightly to the single outlet.<br />
- engage the protective unit cover (3) in the single outlet.<br />
Certificates<br />
In<strong>for</strong>mation<br />
109
110
111
112
113
114
115
116
Conducting electricity.<br />
Routing data.<br />
Controlling energy.<br />
VBS connection and<br />
Fastening systems<br />
Junction box systems<br />
Flush-mounted and hollow wall systems<br />
Clamped systems<br />
Screw-in systems<br />
Fastening systems<br />
Flange clamp systems<br />
Rail systems<br />
Screw-in and knock-in systems<br />
TBS transient voltage and<br />
lightning protection systems<br />
Surge protection systems<br />
Equipotential bonding systems<br />
Lightning protection systems<br />
Earthing systems<br />
KTS <strong>Cable</strong> carrying systems<br />
Installation systems<br />
Rail systems<br />
<strong>Cable</strong> tray systems<br />
Mesh cable tray systems<br />
<strong>Cable</strong> ladder systems<br />
Wide span systems<br />
Ladder systems<br />
Luminaire support systems<br />
Modular systems<br />
Stainless steel systems<br />
Function maintenance and MLAR systems<br />
BSS Fire protection systems<br />
<strong>Cable</strong> routing duct systems<br />
Fire protection duct systems<br />
Function maintenance systems<br />
EGS Device systems<br />
Basic elements<br />
Electronic devices<br />
<strong>OBO</strong> BUS system<br />
Radio systems<br />
Standard range<br />
Dialog range<br />
Aura range<br />
Modul 45 range<br />
Compacta range<br />
Hospital technology<br />
Surface-mounted range<br />
Wet room range<br />
Cast aluminum range<br />
Computer engineering<br />
UFS Underfloor systems<br />
© <strong>OBO</strong> BETTERMANN Order number 9138889 08/2006 GB<br />
MLAR systems<br />
Underfloor installation systems screed-covered<br />
LFS Line installation systems<br />
Line installation duct systems<br />
Baseboard duct systems<br />
Duct systems in-screed, flush with floor surface<br />
Cavity and false-floor systems<br />
Device installation systems<br />
Wiring duct systems<br />
Skirting duct systems<br />
Skirting duct system accessories<br />
Media columns<br />
<strong>OBO</strong> BETTERMANN GmbH & Co. KG<br />
Business unit Ackermann<br />
Wehrstrasse 2 · 51645 Gummersbach<br />
Tel. +49 (0)22 61-832 77 · Fax +49 (0)22 61-836 50<br />
e-mail: export.ackermann@obo.de<br />
www.obo-ackermann.com<br />
<strong>OBO</strong> BETTERMANN GmbH & Co. KG<br />
P.O. Box 1120 · 58694 Menden, Germany<br />
Tel. +49 (0)23 73/89-0 · Fax +49 (0)23 73/89-238<br />
e-mail: info@obo.de · www.obo-bettermann.com