8.2.5.6.7. MC 1....16

8.2.5.6.7. MC 1....16 The table defining consecutive data blocks read from peripheral devices attached to PORT2 operating in GazModem protocol. The table can hold from 1 to 16 independent blocks in one or more devices. Consecutive blocks may encompass Registers from different spaces. 8.2.5.6.7.1. Address Function - Defines address of gas counter from which the configured data block should be read Data type - number Range - 0…65535 Default value - 0 Comments - n/a 8.2.5.6.7.2. Alarm reading Function - defines status of alarm reading from gas meter Data type - selection list List - Yes Reading active No Reading inactive Default value - No Comments - n/a 8.2.5.6.7.3. Signal reading Function - defines status of signal reading from gas meter Data type - selection list List - No Signal reading inactive 1 byte Read 1 signal byte in Gaz-Modem protocol 2 bytes Read 2 signal bytes in Gaz-Modem protocol 3 bytes Read 3 signal bytes in Gaz-Modem protocol 4 bytes Read 4 signal bytes in Gaz-Modem protocol Gazmodem 2 Read signals in Gaz-Modem2 protocol Default value - No Comments - n/a 8.2.5.6.7.4. Current data reading Function - sets status of current data reading from gas meter Data type - selection list List - Yes Current data reading active 55

No Current data reading inactive Default value - No Comments - n/a 8.2.5.6.7.5. Current data block index Function - Defines address of first current data register from peripheral GazModem. device Data type - number Range - 0…64 Default value - 0 Comments - n/a 8.2.5.6.7.6. Current data block length Function - Defines size of current data block read from peripheral GazModem device Data type - number Range - 1…8 Default value - 1 Comments - n/a 8.2.5.7. M-Bus LEC mode CAUTION! This option is not supported since firmware 1.43 in MT-102 modules. The following description is published for legacy support. MT-102 module operating in M-Bus LEC mode along with converter RM-120 plays the role of data converter for data received from heat meters that employ M-Bus protocol. Data received at PORT2 is placed in dedicated registers of the memory map of MT-102. Additionally, in this mode it is possible to attach a gas meter to PORT1 of the MT-102 module. After selecting this mode, local configuration is possible during the first 30s after power-up - PWR LED is flashing. 8.2.5.7.1. Read interval Function - Defines (in seconds) an interval between readings from peripheral device operating on GazModem protocol in order to update measurement data. Data type - number Range - 0…255 [min] Default value - 5 [min] Comments - value 0 (zero) forces max. possible frequency of updating. It depends on speed of PORT2 along with size and number of defined mapped spaces. 56

Telemetry Module MT-100 User Manual - BlueNote Communications
Telemetry Module MT-021 User Manual
Telemetry Module MT-202 User's Manual
Point i/o ethernet/ip adapter module user manual - pacpro
R4 transcription module user manual - Digitalvoice.ie | Digital voice ...
1756-UM521B-EN-P, ControlLogix SynchLink Module User Manual
D-Link EBR-2310 User Manual - Comspan Communications
Acuvim User Manual - MicroDAQ.com
1747-6.5.5, SL 500 DeviceNet Scanner Module User Manual
POINT I/O DeviceNet Adapter User Manual
1756-UM058C-EN-P, ControlLogix Digital I/O Modules User Manual
FLEX I/O EtherNet/IP Adapter Module User Manual, 1794-UM006A ...
375 Field Communicator User's Manual - Emerson Process ...
505U Radio Telemetry Module USER MANUAL - TABATEQ
Telemetry Modules Highlights MT-7x3 MT-713 ... - Welotec GmbH
Radio Telemetry (Wireless I/O), Tabateq Catalogue, User Manual ...
Radio Telemetry Module User Guide - Racelogic
TM1100 Fly-by Telemetry Module Manual - Horizon Hobby
115S Serial I/O Module User Manual - TABATEQ
TM1000 Full Range Telemetry Module Manual - Horizon Hobby
Remote level sensor reading using the MT-101 telemetry ... - Inventia
IND-PWR XXL User Manual - TMS · Telemetrie-Messtechnik ...
ADAM-6024 12 channel Universal Input/Output Module User's Manual
Multi‐function Telemetry Module (MFTM): Wireline link to downhole ...
Q Corresponding Serial Communication Module User's Manual (Basic)
2108 Analog Output Module User Manual - Isco
DeviceNet Communications Module User Manual
Radio Telemetry (Wireless I/O) - Tabateq catalogue - Elpro 505U-K