Rittal – IT Catalogue<br />
R
Communication is the future.<br />
Rittal offers inspiring IT solutions<br />
from the outset.<br />
We have the modules to precisely solve your IT tasks<br />
SIMPLICITY AS THE HIGHEST LEVEL<br />
OF PERFECTION<br />
As little as possible, as much as necessary – find this balance, and you have perfection.<br />
Our IT technology is dynamic and innovative – but we also consciously design it to be<br />
simple. Simplicity is your advantage. In technical terms, this means reducing complex<br />
and complicated correlations to a minimum. In our relationship with you, we take care of<br />
everything so that you needn’t worry about a thing.<br />
Simply perfect, thanks to intelligent system diversity and an holistic approach –<br />
these are customer solutions from Rittal.
CONTENTS<br />
<strong>Networking</strong> . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />
Server racks . . . . . . . . . . . . . . . . . . . . . . . . 72<br />
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . 112<br />
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . 152<br />
Monitoring & remote management . . . . . 186<br />
IT infrastructure/service . . . . . . . . . . . . . . 202<br />
Telecom/distributor racks . . . . . . . . . . . . . 220<br />
Yet more IT solutions . . . . . . . . . . . . . . . . 238<br />
System accessories . . . . . . . . . . . . . . . . . 252<br />
Engineering and consultancy . . . . . . . . . 400<br />
Innovations . . . . . . . . . . . . . . . . . . . . . . . . 422<br />
Rittal IT catalogue<br />
3
Curiosity creates new paths for us to follow.<br />
● Rittal’s permanent innovation achievements are the result<br />
of global dialogue with our customers.<br />
● Our own accredited laboratories guarantee quality and<br />
cost efficiency in accordance with ambitious international<br />
standards, leading to internationally recognised approvals<br />
for global use.<br />
4 Rittal IT catalogue
We give pioneering answers<br />
DETERMINATION IS THE ENGINE<br />
OF PROGRESS<br />
Fascinating future – we see this as much more than just a slogan. We are born to innovate.<br />
We live our passion, which is what makes us truly convincing. This is the only way<br />
for us to be credible, and to achieve lasting success with you.<br />
We realise the importance of continuously building on our outstanding position in order<br />
to rank among the technological leaders in a global market. Wireless, biometrics and<br />
energy-efficient protection are just some of the dynamic technologies we are pursuing<br />
with exceptional commitment and expertise. We are keen to be measured by these<br />
developments in future.<br />
International Rittal research teams are working for the future with clear objectives in mind:<br />
Exceptional benefits for the user, enhanced energy efficiency, and conservation of our<br />
natural resources.<br />
Wireless Energy efficiency Personal identification
We offer system integration – for industry and all sections of the company<br />
COMMUNICATION AS THE BASIS<br />
We live in an information society. Information and data are productivity factors.<br />
Every company and every individual is reliant on information. Those with better, faster<br />
information are able to secure a competitive lead. We ensure that modern IT technology<br />
has the best framework and meets your requirements to perfection.<br />
The Rittal system platforms are called rack, cooling, power, security and monitoring.<br />
Rittal solutions for the physical IT infrastructure are based on an holistic approach,<br />
combined with an exceptional determination to drive progress forwards at every opportunity.<br />
Our philosophy has made us a much sought-after partner.<br />
Talk to us.<br />
Thoroughly modern, scalable and efficient<br />
R<br />
system solutions – that’s Rittal.<br />
6 Rittal IT catalogue
People are at the heart of all communications. They plan<br />
and organise, initiate and control. The IT infrastructure also<br />
has a decisive effect on his efficiency and success. Rittal<br />
offers holistic solutions which embrace all sections of the<br />
company, whatever the industry!<br />
Rack – power – cooling – security – monitoring for<br />
● Data centres<br />
● IT infrastructure<br />
● Data and network technology<br />
● Decentralised computer systems<br />
● Building distribution<br />
● Indoor and outdoor communication<br />
● Industrial Ethernet<br />
Rittal IT catalogue<br />
7
Expertise, customer proximity, quality, deliverability,<br />
product diversity and global service – these are Rittal’s<br />
great strengths.<br />
Around 10,000 Rittal employees around the globe with production<br />
and logistical expertise are working on customised<br />
developments and in modification centres, at:<br />
● 19 production sites<br />
● 60 subsidiaries<br />
● 70 agencies and<br />
● 150 distribution and logistics centres.<br />
8 Rittal IT catalogue
We hold face-to-face meetings . . . at countless national and international trade fairs . . . and at 300 Rittal sites – worldwide.<br />
We are there for you, whenever and wherever you need us<br />
GLOBAL PROXIMITY<br />
To offer customer proximity, you need to be mobile. The desire to keep moving is in<br />
our blood. We are totally and globally customer-oriented. This is a large part of our<br />
attraction, which translates into a genuine added value for you.<br />
We are there for you. We are local. Anywhere in the world. However, for us, customer<br />
proximity is not just geographical; it is also a question of seeking out face-to-face<br />
meetings wherever possible. Because for us, a meeting is the starting point of our<br />
“customer-based” developments, in the most literal sense of the word. We show you<br />
the most innovative, most cost-efficient path.<br />
Requirement analysis, planning, development, prototype construction, modifications,<br />
tests, production, assembly, service and support – that’s Rittal service.<br />
Rittal IT catalogue<br />
9
Extensive technical expertise, well-established structures, and a complete<br />
service chain<br />
EFFICIENCY AS STANDARD<br />
Efficiency is a combination of efficacy plus cost-effectiveness. It sounds easy, and it is,<br />
but only provided all parts work together with optimum interaction between individual<br />
modules. Rittal sets new standards: TBU – Total Benefit of Usership – considers all the<br />
benefits arising from the use of a product. In order to achieve the aspired levels of<br />
availability and reliability (efficacy), the sum total of all purchase and operating costs<br />
(cost-efficiency) must be reduced to a minimum, a process that we have perfected to<br />
a fine art. Energy efficiency comes as standard with Rittal, particularly when it is a<br />
question of supplying complete solutions for optimum reliability and maximum availability<br />
with an appropriate level of investment. This demands integrated solutions, such<br />
as those supplied by Rittal worldwide on every scale. Furthermore, Rittal is distinguished<br />
by the innovative strengths we derive from our relentless curiosity and fascination.<br />
Tailor-made systems, no over-sizing, no unnecessary fixed costs, and where<br />
necessary, simple expansion with the system operational – this is the<br />
“pay-as-you-go” concept from Rittal.<br />
RimatriX5 IT infrastructures Business continuity management Physical IT security
Rittal International, compromising of – Rittal – Litcos – Lampertz –,<br />
offers its customers holistic IT infrastructures from a single source.<br />
High standards of reliability and availability are achieved costeffectively,<br />
with perfect results.<br />
● With RimatriX5, Rittal offers a comprehensive range of services<br />
and a full choice of modules for your rack-based IT infrastructure.<br />
● Litcos: Analytical advice and holistic planning of data centre<br />
structures.<br />
● Lampertz: Modular IT security rooms (room-within-a-room concept)<br />
and IT security cabinets, with an emphasis on fire and theft<br />
protection.<br />
Rittal IT catalogue<br />
11
A complete network of<br />
enclosure solutions<br />
Rittal produces innovative, cost-effective solutions for all<br />
types of IT enclosure systems. Compact, stylish, pre-configured,<br />
and in a wide range of sizes. Moreover, Rittal has<br />
a range of system accessories to suit every enclosure, and<br />
therefore offers a suitable enclosure solution for every application.<br />
Rittal networking always means accessing the<br />
holistic solution; the integrative Rittal system. From power<br />
management, to security and monitoring, through to cooling.<br />
Rittal enclosure solutions are far more than just the width,<br />
height and depth of the enclosure. Instead, they are a<br />
<strong>Networking</strong> from page 14<br />
System comparison of enclosures....................................................14<br />
System comparison of wall-mounted enclosures .............................16<br />
Installation examples ........................................................................18<br />
Network enclosures, based on Rittal TE 7000..................................26<br />
Network enclosures, based on Rittal TS 8........................................32<br />
Network enclosures, based on Rittal flexRack(i) ..............................48<br />
RNC enclosures................................................................................53<br />
Accessories for RNC enclosures......................................................55<br />
Wall-mounted enclosures, based on Rittal QuickBox ......................57<br />
Wall-mounted enclosures, based on Rittal AE .................................60<br />
Wall mounted enclosure, based on Rittal AE, with pull-out frame....61<br />
Wall-mounted enclosures, based on Rittal EL, 3-part ......................62<br />
Wall-mounted enclosures, based on Rittal EL, 2-part ......................66<br />
EMC wall-mounted enclosure, based on Rittal EL, 3-part................67<br />
Small fibre-optic distributors.............................................................68<br />
Small fibre-optic distributors, based on Rittal AE .............................69<br />
Fibre-optic marshalling enclosure ....................................................70<br />
Small fibre-optic distributor, polycarbonate .....................................71<br />
<strong>Networking</strong><br />
complementary network of versatile ideas for adapting to<br />
practical requirements and the needs of the future.<br />
TE 7000 network enclosures<br />
Two depth-variable 482.6 mm (19″)<br />
mounting levels provide a solid framework<br />
(load capacity 400 kg) for all<br />
fixed and patching tasks.<br />
In keeping with the principle “as little<br />
as possible, as much as necessary”,<br />
this rack does not require an<br />
enclosure frame. Benefits: Optimum<br />
accessibility and simple assembly.<br />
A practical, cost-effective solution for<br />
distributors in office environments.<br />
TS 8 network enclosures<br />
A diversity of applications and variability,<br />
both as a distributor and in combination<br />
with installed servers.<br />
Regardless of how demanding your<br />
requirements may be, unrestricted<br />
mounting diversity and a comprehensive<br />
range of system accessories<br />
means that a solution with TS 8 always<br />
offers excellent value for money.<br />
Reliability and availability may be<br />
tailored precisely to requirements,<br />
using modular lock, climate control<br />
and monitoring solutions.<br />
Wall-mounted enclosures<br />
The Rittal wall-mounted range has something<br />
for everyone.<br />
Tailored to IT distribution applications,<br />
they are distinguished by optimum<br />
accessibility, high production<br />
quality, and a comprehensive range of<br />
system accessories.<br />
Rittal IT catalogue/<strong>Networking</strong><br />
13
<strong>Networking</strong><br />
System comparison of enclosures<br />
<strong>Networking</strong><br />
Plan with the best network enclosure for your requirements!<br />
Customers’ requirements of IT enclosures can be<br />
TE 7000<br />
extremely varied. With this in mind, Rittal offers three<br />
different system platforms with outstanding design<br />
features for a variety of applications.<br />
Rittal system comparison TE 7000 TS 8 FR(i)<br />
One platform for all requirements<br />
in the IT market<br />
Load capacity<br />
up to 400/700 kg <br />
up to 1000 kg <br />
Baying<br />
Side to side <br />
In all levels<br />
<br />
Dismantling <br />
Climate control<br />
Fans <br />
Cooling unit<br />
<br />
Air/water<br />
heat exchanger<br />
<br />
CPU liquid cooling <br />
Cabling<br />
Cable space <br />
Cable management <br />
Lock system<br />
2-point <br />
4-point<br />
<br />
Security<br />
Access control <br />
Thermal management <br />
Interior installation<br />
Depth-variable <br />
Partial installation <br />
2-level principle <br />
Aesthetics <br />
Standards<br />
IEC 60 297-1-2 <br />
Protection<br />
categories<br />
Note:<br />
The more the greater the compatibility.<br />
IP 20 <br />
IP 40 <br />
IP 55<br />
<br />
TE 7000 – Top efficiency, the global IT rack<br />
Ready to use for network distribution. As little as possible,<br />
as much as necessary – the rack for rational, costeffective<br />
cabling.<br />
● At its core is the robust frame comprising two<br />
482.6 mm (19″) mounting levels.<br />
● Two-point locking rod, optionally with Ergoform-S<br />
handle system.<br />
● System accessories ensure fast, versatile configuration.<br />
Network enclosures TE 7000, see page 26.<br />
14 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
System comparison of enclosures<br />
Rittal TS 8<br />
Rittal flexRack(i)<br />
<strong>Networking</strong><br />
TS 8 – the Top enclosure system<br />
This offers diversity and protection for your network,<br />
based on the ingenious rack profile. With two levels, it<br />
facilitates unlimited interior installation.<br />
● Suitable for one or two 482.6 mm (19″) mounting<br />
levels, partial or full installation.<br />
● The ingenious symmetry concept of the frame offers<br />
baying on all sides.<br />
● A high level of security, thanks to lock systems with<br />
a comfort handle and 4-point locking.<br />
● Perfect integration of climate control components.<br />
● Protection category up to IP 55.<br />
Network enclosures TS 8, see page 32.<br />
flexRack(i) – The high-end designer rack<br />
A stylish design, a high degree of stability, plus futuristic<br />
technology – with the hollow aluminium section.<br />
● Cables may be routed and system accessories<br />
integrated within the hollow chamber of the frame<br />
section.<br />
● Power management integrated directly into the frame<br />
section. Three-phase infeed using the plug & play<br />
system, with no loss of enclosure volume.<br />
Network enclosures flexRack(i), see page 48.<br />
Rittal IT catalogue/<strong>Networking</strong><br />
15
<strong>Networking</strong><br />
System comparison of wall-mounted enclosures<br />
The configuration of decentralised network units is extremely<br />
<strong>Networking</strong><br />
important for small and medium-sized companies. Rittal has<br />
high-quality solutions to meet virtually every requirement of a<br />
growing network.<br />
RNC enclosure<br />
RNC universal enclosure<br />
Prepared for the installation of<br />
1<br />
/ 219″ components. 10″ components<br />
may also be installed by<br />
using an adaptor. 482.6 mm<br />
(19″) variant for vertical populati<br />
Side panels with integral vent<br />
slots.<br />
The floor-standing enclosure<br />
may also be used as a wallmounted<br />
enclosure with additional<br />
support brackets.<br />
The universal enclosure, vertical<br />
for 19″ installation, horizontal for<br />
1<br />
/ 219″ or 10″ installation.<br />
Bayed for 482.6 mm (19″) configuration,<br />
vertical and horizontal.<br />
Passive ventilation<br />
To accommodate a prepared<br />
fan, cable entry with brush strip.<br />
Wall-mounted enclosures, based on Rittal QuickBox<br />
Cut-outs in the mounting<br />
bracket for access to the rear<br />
of the patch panels or active<br />
components.<br />
Slide rails to support heavy<br />
assemblies.<br />
Vent slots for passive ventilation.<br />
16 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
System comparison of wall-mounted enclosures<br />
Whether fibre-optic or copper distributors, 1 / 219″ or 19″ enclosures,<br />
high protection category or passively vented wall-mounted<br />
enclosures, the IT wall-mounted distributor range covers every<br />
conceivable requirement and is available off the shelf.<br />
<strong>Networking</strong><br />
Wall-mounted and distribution enclosures<br />
Wall-mounted enclosure<br />
based on AE with pull-out frame<br />
or depth-adjustable 482.6 mm<br />
(19″) level.<br />
Small fibre-optic distributor<br />
As a corridor and intermediate<br />
distributor of fibre-optic cables.<br />
Small fibre-optic distributor,<br />
based on AE<br />
The ideal enclosure for breakout<br />
applications.<br />
Fibre-optic marshalling<br />
enclosure<br />
Two access areas:<br />
1. For splicing cassette mounting<br />
2. For the patching chamber.<br />
Small fibre-optic distributors,<br />
polycarbonate, for extreme<br />
conditions with a high protection<br />
category of IP 66 to<br />
EN 60 529/10.91.<br />
Wall-mounted enclosures, based on Rittal EL, 3-part/2-part<br />
Optimum accessibility thanks to<br />
3-part or 2-part vertically hinged<br />
configuration.<br />
Equipped with Mini comfort handle<br />
(3 – 15 U), comfort handle<br />
(18 and 21 U) and replaceable<br />
cable gland plates.<br />
2-part enclosure with swing<br />
frame. Facility for installing subracks<br />
and electronic components.<br />
Rittal IT catalogue/<strong>Networking</strong><br />
17
TE 7000<br />
Network enclosures<br />
This is what TE Top Efficiency looks like!<br />
The rack for rational, cost-effective cabling, ready to use in<br />
<strong>Networking</strong><br />
network distribution:<br />
At its core is the robust frame comprising two 482.6 mm (19″)<br />
attachment levels. Add to this a host of useful accessories<br />
from Rittal’s comprehensive modular system, and you will<br />
arrive at the precise configuration which meets your requirements<br />
to perfection, quickly and cost effectively.<br />
Note:<br />
TE 7000 network enclosures, see page 26.<br />
Parts list with model numbers for this example,<br />
see page 22.<br />
10<br />
12<br />
1<br />
11<br />
2<br />
6<br />
14<br />
13<br />
3<br />
15<br />
7<br />
5<br />
8<br />
9<br />
4<br />
Example: System accessories for perfect configuration of a TE 7000 network enclosure<br />
Use these examples to help you.<br />
Socket strips, lights, cable management<br />
devices and other system accessories are<br />
all available from Rittal, in a wide range of<br />
variants suitable for different applications.<br />
1 Light, 1 U<br />
2 Fan unit, active<br />
3 Fibre-optic cable management panel,<br />
1U<br />
4 Cable routing bar, 1 U<br />
5 Cable routing bar, 4 U<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
Socket strip TE, 8-way<br />
Cable management panel, 1 U<br />
Cable gland panel<br />
Cable routing bar, cranked, 4 U<br />
Component shelf, static installation<br />
Distributor clip, small<br />
Earth rail<br />
Distributor clip, large<br />
Drawer, 2 U<br />
UPS, single-phase<br />
Rittal IT catalogue/<strong>Networking</strong><br />
19
TS 8<br />
Network enclosures<br />
Customised from the modular system – the fast route to a<br />
<strong>Networking</strong><br />
Top solution! Stylish glazed door, maximum installation variability,<br />
and exceptional security thanks to the lock system and<br />
protection category (up to IP 55) – these are the distinguishing<br />
features of the TS 8 Top enclosure system. The symmetrical<br />
layout and two-level principle of the TS 8 section facilitate optimum<br />
space utilisation in every level.<br />
At the same time, the TS 8 is extremely resilient (load capacity<br />
up to 1000 kg) and offers various options for system integration<br />
(power supply, climate control, access protection and<br />
monitoring).<br />
Note:<br />
TS 8 network enclosures, see page 32.<br />
Parts list with model numbers for this example,<br />
see page 23.<br />
7<br />
13<br />
1<br />
14<br />
3<br />
2<br />
5<br />
9<br />
8<br />
15<br />
16<br />
17<br />
4<br />
10<br />
18<br />
11<br />
6<br />
12<br />
Example: System accessories for perfect configuration of a TS 8 network enclosure<br />
Rittal system accessories are available<br />
in many different variants, tailored to the<br />
intended application. 482.6 mm (19″)<br />
partial configuration and the use of component<br />
shelves across the entire enclosure<br />
width are likewise easily achieved.<br />
Use these examples to help you.<br />
1 System light (Linestra)<br />
2 Fan tray<br />
3 Power cable, light<br />
4 Cable routing bar, cranked, 4 U<br />
5 C rails<br />
6 Fibre-optic cable management panel,<br />
1U<br />
7 Cable gland panel<br />
8 Socket strip, 5-way with overvoltage<br />
protection and RFI suppressor filter<br />
9 Socket strip, 7-way<br />
10 Component shelf, 482.6 mm (19″)<br />
installation<br />
11 Telescopic slides for component shelf<br />
12 Cable management panel, 1 U<br />
13 Cable routing bar, 4 U<br />
14 Cable management panel, 1 U<br />
15 Drawer, 2 U<br />
16 Blanking panel, 482.6 mm (19″), 2 U<br />
17 Distributor clip, large<br />
18 UPS, single-phase<br />
Rittal IT catalogue/<strong>Networking</strong><br />
21
<strong>Networking</strong><br />
Parts list for the configuration example TE 7000<br />
<strong>Networking</strong><br />
No. Name Packs of Model No. Page<br />
TE 7000 network enclosure, pre-configured<br />
W = 800 mm, H = 2000 mm, D = 800 mm<br />
1 DK 7000.850 26<br />
Accessories<br />
1 Light, 1 U 1 DK 7109.200 335<br />
2 Fan unit, active 1 DK 7000.670 128<br />
3 Fibre-optic cable management panel, 1 U 1 DK 7256.035 363<br />
4 Cable routing bar, 1 U 10 DK 7111.212 360<br />
5 Cable routing bar, 4 U 4 DK 7111.222 360<br />
6 Socket strip TE, 8-way 1 DK 7000.630 331<br />
7 Cable management panel, 1 U 1 DK 7257.035 361<br />
8 Cable gland panel 1 DK 7140.535 363<br />
9 Cable routing bar, cranked, 4 U 4 DK 7111.220 360<br />
10 Component shelf, static installation 1 DK 7000.620 320<br />
11 Distributor clip, small 4 DK 7111.250 360<br />
12 Earth rail, vertical 1 DK 7113.000 338<br />
13 Distributor clip, large 4 DK 7111.252 360<br />
14 Drawer, 2 U 1 DK 7282.035 385<br />
15 UPS, single-phase 1 DK 7857.430 433<br />
Optional accessories<br />
A Power: Single-phase UPS 433<br />
B Security: Monitoring system CMC-TC 158<br />
C Cooling: Fan systems 123<br />
D Lock systems 282<br />
E Lock cylinder 282<br />
F Cable routing, cable routing bars 360<br />
A<br />
Single-phase UPS<br />
B<br />
Monitoring system CMC-TC<br />
C Fan systems<br />
D<br />
Lock systems<br />
E<br />
Lock cylinder<br />
F<br />
Cable bars<br />
22 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Parts list for the configuration example TS 8<br />
No. Name Packs of Model No. Page<br />
TS 8 network enclosure, pre-configured<br />
W = 800 mm, H = 2000 mm, D = 800 mm<br />
DK 7930.200 32<br />
Accessories<br />
1 System light (Linestra) 1 PS 4103.350 335<br />
2 Fan tray 1 DK 7988.035 127<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
Power cable, light 5 PS 4315.100 336<br />
Cable routing bar, cranked, 4 U 4 DK 7111.220 360<br />
C rails DK 7828.080 307<br />
Fibre-optic cable management panel, 1 U 1 DK 7256.035 363<br />
Cable gland panel 1 DK 7140.535 363<br />
Socket strip, 5-way with overvoltage protection and interference<br />
suppressor filter<br />
1 DK 7240.230 328<br />
Socket strip, 7-way 1 DK 7240.210 328<br />
Component shelf, 482.6 mm (19″) configuration 1 DK 7145.035 319<br />
Telescopic slides for component shelf 2 DK 7081.000 326<br />
Cable management panel, 1 U 1 DK 7257.035 361<br />
Cable routing bar, 4 U 4 DK 7111.222 360<br />
Cable management panel, 1 U 1 DK 7159.035 361<br />
Drawer, 2 U 1 DK 7282.035 385<br />
Blanking panel, 482.6 mm (19″), 2 U 2 DK 7152.035 392<br />
17 Distributor clip, large 4 DK 7111.252 360<br />
18 UPS, single-phase 1 DK 7857.430 433<br />
Optional accessories<br />
A Voltage supply: Energy-Box 332<br />
B Security: Monitoring system CMC-TC 158<br />
C Cable management 350<br />
D 19″ installation system 364<br />
E Doors 277<br />
F Interior installation 295<br />
<strong>Networking</strong><br />
A<br />
Energy Box<br />
B Monitoring system CMC-TC<br />
C<br />
Cable management<br />
D<br />
19″ installation system<br />
E<br />
Designer glazed door<br />
F<br />
Interior installation<br />
Rittal IT catalogue/<strong>Networking</strong><br />
23
Wall-mounted enclosure, 3-part<br />
A high protection category and optimum accessibility thanks to a 3-part, vertically hinged configuration – the EL<br />
wall-mounted enclosure with 482.6 mm (19″) mounting angles is ideally suited for small, decentralised networks,<br />
as a corridor distributor, or for all “Ethernet goes factory” applications. The EL enclosure proves that a protection<br />
category of up to IP 55 is no barrier to an attractive design, making Note:<br />
Wall-mounted enclosure, 3-part,<br />
it particularly suitable for use even in tough industrial environments. see page 62.<br />
1<br />
5<br />
4<br />
7<br />
2<br />
3<br />
6<br />
System accessories for pre-configured wall-mounted enclosure, 3-part (DK 7715.735), W x H x D mm = 600 x 746 x 572.5, 15 U:<br />
1<br />
2<br />
3<br />
Shunting ring with cable shunting ring,<br />
polyamide (DK 7159.035)<br />
2 outlet filters (SK 3322.207),<br />
included in supply<br />
Junction box (DK 7280.035)<br />
4 Mini Comfort handle (DK 7705.120),<br />
included in the supply<br />
5<br />
6<br />
7<br />
Socket strip, 7-way (DK 7240.210)<br />
Component shelf 2 U, static installation<br />
(DK 7119.400)<br />
Earth rail with star earthing (DK 7113.000),<br />
included in the supply<br />
24 Rittal IT catalogue/<strong>Networking</strong>
QuickBox wall-mounted enclosure<br />
Installations that are accessible from all sides are extremely advantageous in day-to-day handling.<br />
The removable cover of the QuickBox complements this to perfection. Other consistent design<br />
features, such as large cut-outs in the mounting<br />
brackets, brush strips and vent slots, make the QuickBox<br />
a universal office distributor.<br />
Note:<br />
QuickBox wall-mounted enclosures,<br />
see page 57.<br />
1<br />
4<br />
2<br />
3<br />
6<br />
5<br />
System accessories for QuickBox wall-mounted enclosure (DK 7502.046), W x H x D mm = 600 x 762 x 600, 15 U:<br />
1<br />
2<br />
3<br />
Mounting angles, 482.6 mm (19″)<br />
(DK 7502.204)<br />
Cable panel with cable shunting ring,<br />
polyamide (DK 7255.035)<br />
Junction box (DK 7280.035)<br />
4<br />
5<br />
Socket strip, 7-way (DK 7240.210)<br />
Component shelf 2 U, static installation<br />
(DK 7119.400)<br />
6 Brush strip top and bottom.<br />
Rittal IT catalogue/<strong>Networking</strong><br />
25
<strong>Networking</strong><br />
Network enclosures TE 7000, pre-configured<br />
T1<br />
B<br />
<strong>Networking</strong><br />
H<br />
T1<br />
B<br />
H<br />
Benefits:<br />
● 19″ mounting angles front and<br />
rear always included<br />
● No frame structure,<br />
optimum accessibility<br />
● Load capacity up to 400 kg<br />
● Pre-configured solution,<br />
including extensive accessory<br />
kit.<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Mounting frame:<br />
Electrophoretic dipcoat-primed<br />
Enclosure panels:<br />
Powder-coated, RAL 7035.<br />
Pre-configured Pre-configured Page<br />
U 24 42<br />
Width (B) mm 1) 800 800<br />
Height (H) mm 1) 1200 2000<br />
Depth (T1) mm 1) 800 800<br />
Distance between 482.6 mm (19″) levels in its delivered state mm 495 495<br />
Model No. TE 7000.840 7000.850<br />
Model No. TE as bayed enclosure without side panels, including baying kit – 7000.852<br />
Supply includes<br />
Self-supporting 482.6 mm (19″) frame structure, depth-variable at the front and rear <br />
Glazed door at the front, including 130° hinge, two-point locking rod, recessed handle and<br />
security lock 3524 E<br />
<br />
<br />
Sheet steel door at the rear, including 130° hinge, two-point locking rod, recessed handle and<br />
security lock 3524 E<br />
<br />
<br />
Pluggable weight-reduced side panels, including security lock 3524 E (7000.850 only)<br />
Base frame with maximum cut-out (for optional population with modular panels, solid,<br />
with passive ventilation or for cable entry)<br />
<br />
<br />
Roof plate including brush strip for cable entry and concealed cut-out for population via the active fan plate <br />
4 levelling feet (including base/plinth adaptor) supplied loose <br />
Spacers, 20 mm, supplied loose to raise the roof <br />
Base/plinth 100 mm, vented <br />
Tested frame earthing to EN 60 950, fitted <br />
Accessory kit<br />
4 C rails, for cable clamping in the enclosure depth via cable clamps, supplied loose <br />
10 cable shunting rings made of plastic, 105 x 70 mm, supplied loose <br />
50 captive nuts, M6, conductive, supplied loose <br />
50 multi-tooth screws, M6, with plastic washers, supplied loose <br />
Premium accessories TE, for direct mounting in the delivered state<br />
Ergoform S handle for semi-cylinder, to exchange for the existing lock 2435.000 2435.000 284<br />
Fan module, with 2 fans and thermostat, pre-wired ready for connection 7000.670 7000.670 128<br />
Slide rail for TE, for attachment between the 482.6 mm (19″) mounting frames, length 424 mm 7963.410 7963.410 384<br />
19″ component shelf for static installation, for direct screw-fastening without an installation kit, 412 mm deep,<br />
load capacity 30 kg, static<br />
7000.620 7000.620 320<br />
Punched section with mounting flange 17 x 73 mm, for mounting installation components, attached in the<br />
enclosure depth between the 482.6 mm (19″) mounting frames<br />
8612.040 8612.040 299<br />
C rail, for cable clamping in the enclosure depth via cable clamps <br />
C rail, for cable clamping in the enclosure width via cable clamps,<br />
on the 482.6 mm (19″) mounting frame at the rear<br />
7828.060 7828.060 307<br />
Cable clamp rail, depth-variable 325 – 575 mm, for cable attachment in the enclosure depth via cable ties 7858.160 7858.160 354<br />
Cable clamp rail for cable attachment in the enclosure depth using cable ties,<br />
on the 482.6 mm (19″) mounting frame at the rear<br />
7828.062 7828.062 354<br />
Earthing kit for TE <br />
Economy socket strip, 8-way for earthing-pin plugs 7000.630 7000.630 331<br />
Included with the supply. 1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
26 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TE 7000, width 600<br />
T<br />
B<br />
H<br />
HE<br />
A<br />
<strong>Networking</strong><br />
19˝<br />
HE = U<br />
A = Defined mounting<br />
distance for Premium<br />
accessories, see below.<br />
Benefits:<br />
● Accessories configured to<br />
order for fast installation<br />
● No frame structure, optimum<br />
accessibility<br />
● Load capacity up to 400 kg<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Mounting frame:<br />
Electrophoretic dipcoat-primed<br />
Enclosure panels:<br />
Powder-coated, RAL 7035/<br />
RAL 9005<br />
Supply includes:<br />
Self-supporting 482.6 mm (19″)<br />
frame structure,<br />
glazed door at the front,<br />
two-point locking rod, recessed<br />
handle and security lock 3524 E,<br />
sheet steel door at rear,<br />
two-point locking rod, recessed<br />
handle and security lock<br />
3524 E, plug-in side panels<br />
with security lock 3524 E,<br />
base frame with maximum<br />
cut-out (for optional population<br />
with module plates), roof plate<br />
for cable entry with concealed<br />
cut-out for fan, levelling feet,<br />
spacers for raising the cover<br />
plate.<br />
Detailed drawing,<br />
available on the Internet.<br />
U 11 11 24 24 42 42 47 47<br />
Width (B) mm 1) 600 600 600 600 600 600 600 600<br />
Height (H) mm 1) 600 600 1200 1200 2000 2000 2200 2200<br />
Depth (T1) mm 1) 600 800 600 800 600 800 600 800<br />
Distance between 482.6 mm (19″) levels<br />
as delivered A mm<br />
495 495 495 495 495 495 495 495<br />
Model No. TE, RAL 7035 7000.390 7000.410 7000.430 7000.440 7000.500 7000.510 7000.560 7000.570<br />
Model No. TE as a bayed enclosure<br />
without side panels, incl. baying kit, RAL 7035<br />
– – – – 7000.502 – 7000.562 –<br />
Model No. TE including side panels, RAL 9005 – – – – 7000.505 2) 7000.515 2) – –<br />
1) All sizes are nominal dimensions. For absolute dimensions, refer to detailed drawings on the Internet. 2) Delivery times on request.<br />
A<br />
B<br />
C<br />
D<br />
495 mm – This is the distance<br />
between the two 482.6 mm<br />
(19″) levels for all enclosure<br />
formats in their delivered state.<br />
Complies with TS 8 nominal<br />
depth 400 mm, inner level.<br />
Pitch spacing 50 mm.<br />
The distance between the two<br />
482.6 mm (19″) levels may be<br />
varied in increments of 50 mm<br />
(445 to 695 mm).<br />
Distance from door:<br />
52.5 mm for depth 600<br />
152.5 mm for depth 800<br />
The mounting distance in a<br />
rear mounting frame, horizontal,<br />
corresponds to the frame<br />
mounting dimensions of a<br />
600 mm wide TS 8 (inner level,<br />
512 mm).<br />
E = A – 120 mm<br />
Choose the distance between<br />
levels completely freely via the<br />
slot fastening. All key mounting<br />
components – punched sections<br />
with mounting flanges, installation<br />
kits, slide rails, component<br />
shelves – are also available in a<br />
depth-variable version.<br />
600<br />
600<br />
A<br />
D<br />
800<br />
600<br />
A<br />
German registered design<br />
no. 403 07 489<br />
D<br />
C<br />
E<br />
A<br />
B<br />
D<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
27
<strong>Networking</strong><br />
Network enclosures, based on Rittal TE 7000, width 600<br />
<strong>Networking</strong><br />
U 11 11 24 24 Page<br />
Width (B) mm 1) 600 600 600 600<br />
Height (H) mm 1) 600 600 1200 1200<br />
Depth (T1) mm 1) 600 800 600 800<br />
Distance between 482.6 mm (19″) levels in its delivered state A mm 495 495 495 495<br />
Model No. TE, RAL 7035 7000.390 7000.410 7000.430 7000.440<br />
Model No. TE as a bayed enclosure without side panels,<br />
incl. baying kit, RAL 7035<br />
– – – –<br />
Model No. TE including side panels, RAL 9005 – – – –<br />
Doors<br />
Glazed front door/sheet steel rear door <br />
Sheet steel front door/sheet steel rear door on request on request on request on request<br />
Ergoform-S handle for semi-cylinder,<br />
in exchange for the existing lock<br />
2435.000 2435.000 2435.000 2435.000 284<br />
Side panel<br />
Side panel, plug-type,<br />
including security lock 3524 E<br />
<br />
Baying kit 7000.640 7000.640 7000.640 7000.640 276<br />
Roof<br />
Roof plate with brush strip for cable entry,<br />
prepared to accommodate an active fan unit<br />
<br />
Fan unit, 2 fans (max. 3) including thermostat 7000.670 7000.670 7000.670 7000.670 128<br />
Fan expansion kit 7980.000 7980.000 7980.000 7980.000 127<br />
Spacers 20 mm to raise the cover plate above<br />
the fan cut-out<br />
<br />
Base/plinth<br />
Roof frame with maximum cut-out for individual population<br />
with module plates, levelling feet M10<br />
<br />
Module plate variants for individual population from page 264 from page 264 from page 264 from page 264<br />
Base/plinth components solid, front and rear 8601.605 8601.605 8601.605 8601.605 255<br />
Base/plinth components, vented, front and rear 7825.601 7825.601 7825.601 7825.601 255<br />
Base/plinth trim, side 8601.065 8601.085 8601.065 8601.085 255<br />
Base/plinth adaptor for levelling feet M12 8800.220 8800.220 8800.220 8800.220 262<br />
Levelling feet M12 4612.000 4612.000 4612.000 4612.000 260<br />
Base/plinth installation accessories from page 254 from page 254 from page 254 from page 254<br />
Interior installation/Premium accessories<br />
482.6 mm (19″) mounting frames front and rear <br />
Punched section with mounting flange 17 x 73 mm, for mounting<br />
installation components, attached in the enclosure depth between 8612.040 8612.040 8612.040 8612.040 299<br />
the 482.6 mm (19″) mounting frames<br />
Cable clamp rail, depth variable 325 – 575 mm,<br />
for cable attachment in the enclosure depth using cable ties<br />
7858.160 7858.160 7858.160 7858.160 354<br />
Cable clamp rail, for cable attachment in the enclosure width via<br />
cable ties, on the 482.6 mm (19″) mounting frame at the rear<br />
7828.062 7828.062 7828.062 7828.062 354<br />
C rail, for cable clamping in the enclosure depth via cable clamps 7828.040 7828.040 7828.040 7828.040 307<br />
C rail, for cable clamping in the enclosure width via cable clamps,<br />
on the 482.6 mm (19″) mounting frame at the rear<br />
7828.060 7828.060 7828.060 7828.060 307<br />
Earthing kit for TE 7000.675 7000.675 7000.675 7000.675 339<br />
TE socket strip, 8-way with earthing-pin plug 7000.630 7000.630 7000.630 7000.630 331<br />
Power accessories from page 328 from page 328 from page 328 from page 328<br />
Slide rail for TE, for attachment between the 482.6 mm (19″)<br />
mounting frames, length 424 mm<br />
7963.410 7963.410 7963.410 7963.410 384<br />
482.6 mm (19″) component shelf for static installation,<br />
for direct screw-fastening wtihout installation kit, 412 mm deep,<br />
7000.620 7000.620 7000.620 7000.620 320<br />
load capacity 30 kg, static<br />
Cable management from page 341 from page 341 from page 341 from page 341<br />
CMC-TC monitoring system from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
28 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TE 7000, width 600<br />
<strong>Networking</strong><br />
U 42 42 47 47 Page<br />
Width (B) mm 1) 600 600 600 600<br />
Height (H) mm 1) 2000 2000 2200 2200<br />
Depth (T1) mm 1) 600 800 600 800<br />
Distance between 482.6 mm (19″) levels in its delivered state A mm 495 495 495 495<br />
Model No. TE, RAL 7035 7000.500 7000.510 7000.560 7000.570<br />
Model No. TE as a bayed enclosure without side panels,<br />
incl. baying kit, RAL 7035<br />
7000.502 – 7000.562 –<br />
Model No. TE including side panels, RAL 9005 7000.505 2) 7000.515 2) – –<br />
Doors<br />
Glazed front door/sheet steel rear door <br />
Sheet steel front door/sheet steel rear door on request on request on request on request<br />
Ergoform-S handle for semi-cylinder,<br />
in exchange for the existing lock<br />
2435.000 2435.000 2435.000 2435.000 284<br />
Side panel<br />
Side panel, plug-type,<br />
including security lock 3524 E<br />
(7000.500,<br />
7000.505 only)<br />
(7000.560 only) 266<br />
Baying kit (7000.502 only) 7000.640 (7000.562 only) 7000.640 276<br />
Roof<br />
Roof plate with brush strip for cable entry,<br />
prepared to accommodate an active fan unit<br />
<br />
Fan unit, 2 fans (max. 3) including thermostat 7000.670 7000.670 7000.670 7000.670 128<br />
Fan expansion kit 7980.000 7980.000 7980.000 7980.000 127<br />
Spacers 20 mm to raise the cover plate above the fan cut-out <br />
Base/plinth<br />
Base frame with max. cut-out for individual population with module<br />
plates, levelling feet M10<br />
<br />
Module plate variants for individual population from page 264 from page 264 from page 264 from page 264<br />
Base/plinth components solid, front and rear 8601.605 8601.605 8601.605 8601.605 255<br />
Base/plinth components, vented, front and rear 7825.601 7825.601 7825.601 7825.601 255<br />
Base/plinth trim, side 8601.065 8601.085 8601.065 8601.085 255<br />
Base/plinth adaptor for levelling feet M12 8800.220 8800.220 8800.220 8800.220 262<br />
Levelling feet M12 4612.000 4612.000 4612.000 4612.000 260<br />
Base/plinth installation accessories from page 254 from page 254 from page 254 from page 254<br />
Interior installation/Premium accessories<br />
482.6 mm (19″) mounting frames front and rear <br />
Punched section with mounting flange 17 x 73 mm, for mounting<br />
installation components, attached in the enclosure depth between 8612.040 8612.040 8612.040 8612.040 299<br />
the 482.6 mm (19″) mounting frames<br />
Cable clamp rail, depth variable 325 – 575 mm,<br />
for cable attachment in the enclosure depth using cable ties<br />
7858.160 7858.160 7858.160 7858.160 354<br />
Cable clamp rail, for cable attachment in the enclosure width via<br />
cable ties, on the 482.6 mm (19″) mounting frame at the rear<br />
7828.062 7828.062 7828.062 7828.062 354<br />
C rail, for cable clamping in the enclosure depth via cable clamps 7828.040 7828.040 7828.040 7828.040 307<br />
C rail, for cable clamping in the enclosure width via cable clamps,<br />
on the 482.6 mm (19″) mounting frame at the rear<br />
7828.060 7828.060 7828.060 7828.060 307<br />
Earthing kit for TE 7000.675 7000.675 7000.675 7000.675 339<br />
TE socket strip, 8-way with earthing-pin plug 7000.630 7000.630 7000.630 7000.630 331<br />
Power accessories from page 328 from page 328 from page 328 from page 328<br />
Slide rail for TE, for attachment between the 482.6 mm (19″)<br />
mounting frames, length 424 mm<br />
7963.410 7963.410 7963.410 7963.410 384<br />
482.6 mm (19″) component shelf for static installation,<br />
for direct screw-fastening without an installation kit, 412 mm deep, 7000.620 7000.620 7000.620 7000.620 320<br />
load capacity 30 kg, static<br />
Cable management from page 341 from page 341 from page 341 from page 341<br />
CMC-TC monitoring system from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1)<br />
All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
29
<strong>Networking</strong><br />
Network enclosures, based on Rittal TE 7000, width 800<br />
T1<br />
B<br />
<strong>Networking</strong><br />
H<br />
HE<br />
A<br />
19˝<br />
HE = U<br />
A = Defined mounting<br />
distance for Premium<br />
accessories, see below.<br />
Benefits:<br />
● Accessories configured to<br />
order for fast installation<br />
● No frame structure, optimum<br />
accessibility<br />
● Load capacity up to 400 kg<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Mounting frame:<br />
Electrophoretic dipcoat-primed<br />
Enclosure panels:<br />
Powder-coated, RAL 7035/<br />
RAL 9005<br />
Supply includes:<br />
Self-supporting 482.6 mm (19″)<br />
frame structure,<br />
glazed door at the front,<br />
two-point locking rod, recessed<br />
handle and security lock 3524 E,<br />
sheet steel door at rear,<br />
two-point locking rod, recessed<br />
handle and security lock<br />
3524 E, plug-in side panels<br />
with security lock 3524 E,<br />
base frame with maximum<br />
cut-out (for optional population<br />
with module plates), roof plate<br />
for cable entry with concealed<br />
cut-out for fan, levelling feet,<br />
spacers for raising the cover<br />
plate.<br />
Detailed drawing,<br />
available on the Internet.<br />
U 24 24 42 42 47 47<br />
Width (B) mm 1) 800 800 800 800 800 800<br />
Height (H) mm 1) 1200 1200 2000 2000 2200 2200<br />
Depth (T1) mm 1) 600 800 600 800 600 800<br />
Distance between 482.6 mm (19″) levels in its delivered state A mm 495 495 495 495 495 495<br />
Model No. TE, RAL 7035 7000.450 7000.460 7000.520 7000.530 7000.580 7000.590<br />
Model No. TE as bayed enclosure without side panels, including baying<br />
kit, RAL 7035<br />
– – – 7000.532 – 7000.592<br />
Model No. TE including side panels, RAL 9005 – – 7000.525 2) 7000.535 2) – –<br />
1) All sizes are nominal dimensions. For absolute dimensions, refer to detailed drawings on the Internet. 2) Delivery times on request.<br />
A<br />
B<br />
C<br />
D<br />
495 mm – This is the distance<br />
between the two 482.6 mm<br />
(19″) levels for all enclosure<br />
formats in their delivered state.<br />
Complies with TS 8 nominal<br />
depth 400 mm, inner level.<br />
Pitch spacing 50 mm.<br />
The distance between the two<br />
482.6 mm (19″) levels may be<br />
varied in increments of 50 mm<br />
(445 to 695 mm).<br />
Distance from door:<br />
52.5 mm for depth 600<br />
152.5 mm for depth 800<br />
The mounting distance in a<br />
rear mounting frame, horizontal,<br />
corresponds to the frame<br />
mounting dimensions of a<br />
600 mm wide TS 8 (inner level,<br />
512 mm).<br />
E = A – 120 mm<br />
Choose the distance between<br />
levels completely freely via the<br />
slot fastening. All key mounting<br />
components – punched sections<br />
with mounting flanges, installation<br />
kits, slide rails, component<br />
shelves – are also available in a<br />
depth-variable version.<br />
600<br />
800<br />
A<br />
D<br />
800<br />
German registered design<br />
no. 403 07 489<br />
800<br />
A<br />
D<br />
C<br />
E<br />
A<br />
B<br />
D<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
30 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TE 7000, width 800<br />
<strong>Networking</strong><br />
U 24 24 42 42 47 47 Page<br />
Width (B) mm 1) 800 800 800 800 800 800<br />
Height (H) mm 1) 1200 1200 2000 2000 2200 2200<br />
Depth (T1) mm 1) 600 800 600 800 600 800<br />
Distance between 482.6 mm (19″) levels in its delivered state A mm 495 495 495 495 495 495<br />
Model No. TE, RAL 7035 7000.450 7000.460 7000.520 7000.530 7000.580 7000.590<br />
Model No. TE as a bayed enclosure without side panels,<br />
incl. baying kit, RAL 7035<br />
– – – 7000.532 – 7000.592<br />
Model No. TE including side panels, RAL 9005 – – 7000.525 2) 7000.535 2) – –<br />
Doors<br />
Glazed front door/sheet steel rear door <br />
Sheet steel front door/sheet steel rear door on request on request on request on request on request on request<br />
Ergoform-S handle for semi-cylinder,<br />
in exchange for the existing lock<br />
2435.000 2435.000 2435.000 2435.000 2435.000 2435.000 284<br />
Side panel<br />
Side panel, plug-type,<br />
including security lock 3524 E<br />
<br />
( 7000.530,<br />
7000.535<br />
only)<br />
<br />
(7000.590<br />
only)<br />
Baying kit 7000.640 7000.640 7000.640<br />
(7000.532<br />
(7000.592<br />
7000.640<br />
only)<br />
only)<br />
276<br />
Roof<br />
Roof plate with brush strip for cable entry,<br />
prepared to accommodate an active fan unit<br />
<br />
Fan unit, 2 fans (max. 3) including thermostat 7000.670 7000.670 7000.670 7000.670 7000.670 7000.670 128<br />
Fan expansion kit 7980.000 7980.000 7980.000 7980.000 7980.000 7980.000 127<br />
Spacers 20 mm to raise the cover plate above the fan cut-out <br />
Base/plinth<br />
Base frame with max. cut-out for individual population with module<br />
plates, levelling feet M10<br />
<br />
Module plate variants for individual population from p. 264 from p. 264 from p. 264 from p. 264 from p. 264 from p. 264<br />
Base/plinth components solid, front and rear 8601.805 8601.805 8601.805 8601.805 8601.805 8601.805 255<br />
Base/plinth components, vented, front and rear 7825.801 7825.801 7825.801 7825.801 7825.801 7825.801 255<br />
Base/plinth trim, side 8601.065 8601.085 8601.065 8601.085 8601.065 8601.085 255<br />
Base/plinth adaptor for levelling feet M12 8800.220 8800.220 8800.220 8800.220 8800.220 8800.220 262<br />
Levelling feet M12 4612.000 4612.000 4612.000 4612.000 4612.000 4612.000 260<br />
Interior installation/Premium accessories<br />
482.6 mm (19″) mounting frames front and rear <br />
Punched section with mounting flange 17 x 73 mm, for mounting<br />
installation components, attached in the enclosure depth between 8612.040 8612.040 8612.040 8612.040 8612.040 8612.040 299<br />
the 482.6 mm (19″) mounting frames<br />
Cable clamp rail, depth variable 325 – 575 mm,<br />
for cable attachment in the enclosure depth using cable ties<br />
7858.160 7858.160 7858.160 7858.160 7858.160 7858.160 354<br />
Cable clamp rail, for cable attachment in the enclosure width via<br />
cable ties, on the 482.6 mm (19″) mounting frame at the rear<br />
7828.062 7828.062 7828.062 7828.062 7828.062 7828.062 354<br />
C rail, for cable clamping in the enclosure depth via cable clamps 4943.000 4943.000 4943.000 4943.000 4943.000 4943.000 307<br />
C rail, for cable clamping in the enclosure width via cable clamps,<br />
on the 482.6 mm (19″) mounting frame at the rear<br />
7828.060 7828.060 7828.060 7828.060 7828.060 7828.060 307<br />
Earthing kit for TE 7000.675 7000.675 7000.675 7000.675 7000.675 7000.675 339<br />
TE socket strip, 8-way with earthing-pin plug 7000.630 7000.630 7000.630 7000.630 7000.630 7000.630 331<br />
Power accessories from p. 328 from p. 328 from p. 328 from p. 328 from p. 328 from p. 328<br />
Slide rail for TE, for attachment between the 482.6 mm (19″)<br />
mounting frames, length 424 mm<br />
7963.410 7963.410 7963.410 7963.410 7963.410 7963.410 384<br />
482.6 mm (19″) component shelf for static installation,<br />
for direct screw-fastening without an installation kit, 412 mm deep, 7000.620 7000.620 7000.620 7000.620 7000.620 7000.620 320<br />
load capacity 30 kg, static<br />
Cable management from p. 341 from p. 341 from p. 341 from p. 341 from p. 341 from p. 341<br />
CMC-TC monitoring system from p. 158 from p. 158 from p. 158 from p. 158 from p. 158 from p. 158<br />
Included with the supply.<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
266<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
31
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, pre-configured<br />
T1<br />
B1<br />
T1<br />
B1<br />
H2<br />
H2<br />
H1<br />
H3<br />
H1<br />
<strong>Networking</strong><br />
H3<br />
B2<br />
T2<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure frame:<br />
Dipcoat-primed<br />
Doors, roof and base/plinth:<br />
Dipcoat-primed,<br />
powder-coated in RAL 7035<br />
Gland plates, punched sections<br />
with mounting flanges and<br />
mounting angles:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
Enclosure frame with doors or<br />
rear panel, roof plate, vented<br />
base/plinth 100 mm,<br />
earthing of all enclosure panels;<br />
Supplied loose:<br />
Levelling feet incl. base/plinth<br />
adaptor,<br />
4 spacers, for raising the roof,<br />
4 cable clamp rails for the inner<br />
frame level,<br />
10 cable shunting rings<br />
(105 x 70 mm, plastic, for<br />
DK 7930.100 in 44 x 70 mm),<br />
50 captive nuts, M6, conductive,<br />
50 multi-tooth screws M6.<br />
Version 1<br />
Designer glazed door at the<br />
front, 180°, with comfort handle<br />
for semi-cylinder and security<br />
lock 3524 E;<br />
Sheet steel door at the rear,<br />
130°, with swivel handle and<br />
security lock 3524 E.<br />
482.6 mm (19″) mounting<br />
angles, front, fitted approx.<br />
150 mm behind the frame front<br />
edge, screw-fastened to the TS<br />
punched sections with mounting<br />
flange as depth stays.<br />
Gland plate, one-piece, vented,<br />
with cable entry.<br />
Version 2<br />
Designer glazed door at the<br />
front, 180°, with comfort handle<br />
for semi-cylinder and security<br />
lock 3524 E;<br />
Sheet steel door at the rear,<br />
130°, with swivel handle and<br />
security lock 3524 E.<br />
482.6 mm (19″) mounting<br />
angles<br />
at the front and rear, distance<br />
between levels pre-configured<br />
at 498 mm. Cranked mounting<br />
angles screw-fastened to installation<br />
brackets approx. 150 mm<br />
behind the frame front edge.<br />
Gland plate at the front, fitted as<br />
an infill panel.<br />
Detailed drawing,<br />
available on the Internet.<br />
Version 1 Version 2 Version 2 Version 2<br />
U 24 38 42 47<br />
Width (B1) mm 1) 600 800 800 800<br />
Height (H1 + H2) mm 1) 1200 + 100 1800 + 100 2000 + 100 2200 + 100<br />
Depth (T1) mm 1) 600 800 800 800<br />
Clearance width (B2) mm 512 712 712 712<br />
Clearance height (H3) mm 1112 1712 1912 2112<br />
Clearance depth (T2) in mm 512 712 712 712<br />
Model No. DK including 2 plug-in side panels,<br />
with security lock 3524 E<br />
Model No. DK as a bayed enclosure without side panels,<br />
incl. baying kit TS 8800.500<br />
7930.100 3) 7930.800 3) 7930.200 3) 7930.220 3)<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
3) Aluminium glazed door, delivery times available on request.<br />
– 7930.850 2)3) 7930.250 3) 7930.270 2)3)<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
32 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, pre-configured<br />
Version 1 Version 2 Version 2 Version 2 Page<br />
<strong>Networking</strong><br />
U 24 38 42 47<br />
Width (B1) mm 1) 600 800 800 800<br />
Height (H1 + H2) mm 1) 1200 + 100 1800 + 100 2000 + 100 2200 + 100<br />
Depth (T1) mm 1) 600 800 800 800<br />
Model No. DK including 2 plug-in side panels,<br />
with security lock 3524 E<br />
Model No. DK as bayed enclosure without side<br />
panels, including baying kit TS 8800.500<br />
7930.100 7930.800 7930.200 7930.220<br />
– 7930.850 2) 7930.250 7930.270 2)<br />
Doors<br />
Designer glazed front door/sheet steel rear door <br />
Various door options from page 277 from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 (7930.800 only) (7930.200 only) (7930.220 only)<br />
Lock for side panel, plug-in, 3524 E <br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8170.235 8188.235 8108.235 8128.235 265<br />
Baying from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Roof plate for cable entry <br />
Roof plate, vented 7826.766 7826.788 7826.788 7826.788 293<br />
Roof plate, vented, for cable entry 7826.669 7826.889 7826.889 7826.889 293<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128<br />
Fan mounting plate, active, with controller 7966.035 7988.035 7988.035 7988.035 127<br />
DC fan mounting plate with FCS speed control – 7858.488 7858.488 7858.488 124<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 293<br />
Base/plinth<br />
Base/plinth components, solid,<br />
front and rear<br />
8601.605 8601.805 8601.805 8601.805 255<br />
Gland plate, multi-piece – 7825.382 7825.382 7825.382 263<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, cranked<br />
(for network technology)<br />
Punched section with mounting flange, interior<br />
installation rail systems<br />
<br />
(front)<br />
<br />
(front and rear)<br />
<br />
(front and rear)<br />
<br />
(front and rear)<br />
from page 295 from page 295 from page 295 from page 295<br />
Cable clamp rails, C rails see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation <br />
Socket strips, power management from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
33
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, pre-configured<br />
T1<br />
B1<br />
T1<br />
B1<br />
H2<br />
H2<br />
H1<br />
H3<br />
H1<br />
<strong>Networking</strong><br />
H3<br />
B2<br />
T2<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure frame:<br />
Dipcoat-primed<br />
Doors, roof and base/plinth:<br />
Dipcoat-primed,<br />
powder-coated in RAL 7035<br />
Gland plates, punched sections<br />
with mounting flanges and<br />
mounting angles:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
System frame with doors or rear<br />
panel, roof plate,<br />
vented base/plinth 100 mm,<br />
earthing of all enclosure panels;<br />
Supplied loose:<br />
Levelling feet incl. base/plinth<br />
adaptor,<br />
4 spacers, for raising the roof,<br />
4 cable clamp rails for the inner<br />
frame level,<br />
10 cable shunting rings<br />
(105 x 70 mm, plastic),<br />
50 captive nuts, M6, conductive,<br />
50 multi-tooth screws M6.<br />
Version 3<br />
Glazed front door, vented, 180°,<br />
with comfort handle for semicylinder<br />
and security lock<br />
3524 E;<br />
Sheet steel door at the rear,<br />
180°, with swivel handle and<br />
security lock 3524 E.<br />
482.6 mm (19″) mounting<br />
angles<br />
at the front and rear, distance<br />
between levels pre-configured<br />
at 745 mm.<br />
L-shaped mounting angles<br />
screw-fastened to 2 or 3 depth<br />
stays respectively.<br />
Gland plate, one-piece, vented,<br />
with cable entry.<br />
Detailed drawing,<br />
available on the Internet.<br />
Version 3 Version 3 Version 3 Version 3 Version 3<br />
U 24 42 42 47 47<br />
Width (B1) mm 1) 800 800 800 800 800<br />
Height (H1 + H2) mm 1) 1200 + 100 2000 + 100 2000 + 100 2200 + 100 2200 + 100<br />
Depth (T1) mm 1) 900 900 1000 900 1000<br />
Clearance width (B2) mm 712 712 712 712 712<br />
Clearance height (H3) mm 1112 1912 1912 2112 2112<br />
Clearance depth (T2) in mm 812 812 912 812 912<br />
Model No. DK including 2 plug-in side panels,<br />
with security lock 3524 E<br />
Model No. DK as a bayed enclosure without side panels,<br />
incl. baying kit TS 8800.500<br />
7830.120 7830.300 7830.330 7830.320 2) 7830.340 2)<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2)<br />
Delivery times available on request.<br />
– 7830.350 7830.335 7830.370 2) 7830.380 2)<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
34 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, pre-configured<br />
Version 3 Version 3 Version 3 Version 3 Version 3 Page<br />
<strong>Networking</strong><br />
U 24 42 42 47 47<br />
Width (B1) mm 1) 800 800 800 800 800<br />
Height (H1 + H2) mm 1) 1200 + 100 2000 + 100 2000 + 100 2200 + 100 2200 + 100<br />
Depth (T1) mm 1) 900 900 1000 900 1000<br />
Model No. DK including 2 plug-in side panels,<br />
with security lock 3524 E<br />
Model No. DK as bayed enclosure without side<br />
panels, including baying kit TS 8800.500<br />
7830.120 7830.300 7830.330 7830.320 2) 7830.340 2)<br />
– 7830.350 7830.335 7830.370 2) 7830.380 2)<br />
Doors<br />
Glazed front door/sheet steel rear door, vented <br />
Various door options from page 277 from page 277 from page 277 from page 277 from page 277<br />
Side panel<br />
Side panel, plug-in, IP 20 (7830.300 only) (7830.330 only) (7830.320 only) (7830.340 only)<br />
Lock for side panel, plug-in, 3524 E <br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 – 8109.235 8100.235 8129.235 – 265<br />
Baying from page 270 from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Roof plate for cable entry <br />
Roof plate, vented 7826.789 7826.789 7826.780 7826.789 7826.780 293<br />
Roof plate, vented, for cable entry 7826.899 7826.899 7826.809 7826.899 7826.809 293<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128 see page 128<br />
Fan mounting plate, active, with controller 7988.035 7988.035 7988.035 7988.035 7988.035 127<br />
DC fan mounting plate with FCS speed control 7858.488 7858.488 7858.488 7858.488 7858.488 124<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 7967.000 293<br />
Base/plinth<br />
Base/plinth components, solid,<br />
front and rear<br />
8601.805 8601.805 8601.805 8601.805 8601.805 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, L-shaped<br />
(for server technology)<br />
(front and rear) (front and rear) (front and rear) (front and rear)<br />
Punched section with mounting flange, interior<br />
installation rail systems<br />
from page 295 from page 295 from page 295 from page 295 from page 295<br />
Cable clamp rails, C rails see page 307 see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation <br />
Socket strips, power management from page 328 from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
35
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, pre-configured<br />
T1<br />
B1<br />
T1<br />
B1<br />
H2<br />
H1<br />
<strong>Networking</strong><br />
H3<br />
B2<br />
T2<br />
H2<br />
H3<br />
H1<br />
H4<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure frame:<br />
Dipcoat-primed<br />
Doors, roof and base/plinth:<br />
Dipcoat-primed,<br />
powder-coated in RAL 7035<br />
Gland plates, punched sections<br />
with mounting flanges and<br />
mounting angles:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
System frame with doors or rear<br />
panel, roof plate,<br />
vented base/plinth 100 mm,<br />
earthing of all enclosure panels;<br />
Supplied loose:<br />
Levelling feet incl. base/plinth<br />
adaptor,<br />
4 spacers for raising the roof or<br />
vent panel,<br />
4 cable clamp rails for the inner<br />
frame level,<br />
10 cable shunting rings<br />
(105 x 70 mm, plastic),<br />
50 captive nuts, M6, conductive,<br />
50 multi-tooth screws M6.<br />
Version 4<br />
Designer glazed door at the<br />
front, 180°, with comfort handle<br />
for semi-cylinder and security<br />
lock 3524 E;<br />
Sheet steel door at the rear,<br />
130°, with swivel handle and<br />
security lock 3524 E.<br />
Empty enclosure for individual<br />
configuration, 482.6 mm (19″)/<br />
metric partial installation or a<br />
combination of mounting angles/<br />
482.6 mm (19″) mounting<br />
frames supported. Gland plate<br />
at the front, fitted as an infill<br />
panel.<br />
Version 5<br />
Designer glazed door at the<br />
front, 180°, with comfort handle<br />
for semi-cylinder and security<br />
lock 3524 E;<br />
Sheet steel door at the rear,<br />
130°, with swivel handle and<br />
security lock 3524 E.<br />
482.6 mm (19″) mounting<br />
angles at the front and rear, distance<br />
between levels 598 mm.<br />
L-shaped mounting angles<br />
screw-fastened to depth stays in<br />
the centre. Roof plate with cutout<br />
for fan insert and vent panel<br />
on spacers. Gland plate at the<br />
front, fitted as an infill panel.<br />
Version 6<br />
Designer glazed door at the<br />
front, 180°, with comfort handle<br />
for semi-cylinder and security<br />
lock 3524 E.<br />
Sheet steel rear panel.<br />
Swing frame, large, with side<br />
trim panel for the installation of<br />
482.6 mm (19″) mounting components<br />
whilst utilising the full<br />
enclosure height (130°, 150 kg).<br />
Full installation at the front, rear<br />
panel, including swing frame<br />
installation kit SR 1995.825 up to<br />
150 kg total load capacity,<br />
static. Roof plate with cut-out for<br />
fan insert and vent panel on<br />
spacers. Gland plate, onepiece,<br />
vented, with cable entry.<br />
Detailed drawing,<br />
available on the Internet.<br />
Version 4 Version 5 Version 6<br />
U 42 42 40<br />
Width (B1) mm 1) 800 800 800<br />
Height (H1 + H2) mm, (H1 + H2 + H4) mm 1) 2000 + 100 2000 + 100 + 25 2000 + 100 + 25<br />
Depth (T1) mm 1) 800 800 800<br />
Clearance width (B2) mm 712 712 712<br />
Clearance height (H3) mm 1912 1912 1912<br />
Clearance depth (T2) in mm 712 712 712<br />
Model No. DK including 2 plug-in side panels,<br />
with security lock 3524 E<br />
Model No. DK as a bayed enclosure without side panels,<br />
incl. baying kit TS 8800.500<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
3) Aluminium glazed door, delivery times available on request.<br />
7930.400 3) 7930.500 3) 7930.660 3)<br />
– 7930.550 2)3) 7930.670 2)3)<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
36 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, pre-configured<br />
Version 4 Version 5 Version 6 Page<br />
<strong>Networking</strong><br />
U – 42 40<br />
Width (B1) mm 1) 800 800 800<br />
Height (H1 + H2) mm, (H1 + H2 + H4) mm 1) 2000 + 100 2000 + 100 + 25 2000 + 100 + 25<br />
Depth (T1) mm 1) 800 800 800<br />
Model No. DK including 2 plug-in side panels,<br />
with security lock 3524 E<br />
Model No. DK as a bayed enclosure without side panels,<br />
incl. baying kit TS 8800.500<br />
7930.400 7930.500 7930.660<br />
– 7930.550 2) 7930.670 2)<br />
Doors<br />
Designer glazed front door/sheet steel rear door –<br />
Designer glazed front door/sheet steel rear panel – – <br />
Various door options from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 – 288<br />
Side panel<br />
Side panel, plug-in, IP 20 (7930.500 only) (7930.660 only)<br />
Lock for side panel, plug-in, 3524 E <br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8108.235 8108.235 8108.235 265<br />
Baying from page 270 from page 270 from page 270<br />
Roof<br />
Roof plate for cable entry 7826.885 7826.885 292<br />
Roof plate, vented 7826.788 7826.788 7826.788 293<br />
Roof plate, vented, for cable entry 7826.889 7826.889 7826.889 293<br />
Fan roof, modular see page 128<br />
<br />
<br />
(without fan insert) (without fan insert)<br />
Fan mounting plate, active, with controller 7988.035 – – 127<br />
DC fan mounting plate with FCS speed control 7858.488 7858.488 – 124<br />
Spacers, 50 mm 7967.000 – – 293<br />
Base/plinth<br />
Base/plinth components, solid,<br />
front and rear<br />
8601.805 8601.805 8601.805 255<br />
Gland plate, multi-piece 7825.382 7825.382 – 263<br />
Gland plate variants from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, L-shaped<br />
(for server technology)<br />
from page 364<br />
<br />
(front and rear)<br />
19″ large swing frame<br />
(40 U)<br />
Punched section with mounting flange, interior installation rail systems from page 295 from page 295 from page 295<br />
Cable clamp rails, C rails see page 307 see page 307 see page 307<br />
Earthing/potential equalisation <br />
Socket strips, power management from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
37
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, types 1 and 2<br />
T1<br />
B1<br />
T1<br />
B1<br />
<strong>Networking</strong><br />
H2<br />
B2<br />
H1<br />
H1<br />
T2<br />
Type 1<br />
Designer glazed door at the<br />
front (180°), with 3 mm singlepane<br />
safety glass, comfort<br />
handle for semi-cylinder and<br />
security lock 3524 E;<br />
sheet steel door at the rear<br />
(130°) with handle and security<br />
lock 3524 E.<br />
Type 2<br />
Sheet steel door at front (180°),<br />
with comfort handle for semicylinder<br />
and security lock<br />
3524 E;<br />
sheet steel door at the rear<br />
(130°) with handle and security<br />
lock 3524 E.<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure frame:<br />
Dipcoat-primed<br />
Doors and roof: Dipcoat-primed,<br />
powder-coated in RAL 7035<br />
Base plates and punched<br />
sections with mounting flanges:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
Enclosure frame with doors,<br />
roof plate, multi-piece gland<br />
plate, 2 punched sections with<br />
mounting flanges in the enclosure<br />
depth.<br />
Approvals,<br />
see page 402.<br />
Detailed drawing,<br />
available on the Internet.<br />
U 15 20 20 24 24 24 24 24<br />
Width (B1) mm 1) 600 600 800 600 800 800 800 800<br />
Height (H1) mm 1) 800 1000 1000 1200 1200 1200 1200 1200<br />
Depth (T1) mm 1) 600 600 600 600 600 800 900 1000<br />
Clearance width (B2) mm 512 512 712 512 712 712 712 712<br />
Clearance height (H2) mm 712 912 912 1112 1112 1112 1112 1112<br />
Clearance depth (T2) mm 512 512 512 512 512 712 812 912<br />
Model No. DK,<br />
type 1 with designer glazed door<br />
at the front<br />
Model No. DK,<br />
type 2 with sheet steel door<br />
at the front<br />
7920.100 3) 7920.200 3) 7920.240 2)3) 7920.300 3) 7920.340 2)3) 7920.350 3) 7920.355 3) 7920.360 2)3)<br />
7821.100 7821.200 7821.240 2) 7821.300 7821.340 – 7821.355 –<br />
U 29 29 29 33 33 33 38 38<br />
Width (B1) mm 1) 600 600 800 600 600 800 600 600<br />
Height (H1) mm 1) 1400 1400 1400 1600 1600 1600 1800 1800<br />
Depth (T1) mm 1) 600 800 600 600 800 600 600 800<br />
Clearance width (B2) mm 512 512 712 712 512 712 712 512<br />
Clearance height (H2) mm 1312 1312 1312 1512 1512 1512 1512 1712<br />
Clearance depth (T2) mm 512 712 512 512 712 512 512 712<br />
Model No. DK,<br />
type 1 with designer glazed door 7920.400 2)3) 7920.410 3) 7920.440 2)3) 7920.500 3) 7920.510 3) 7920.540 2)3) 7920.600 3) 7920.610 3)<br />
at the front<br />
Model No. DK,<br />
type 2 with sheet steel door<br />
7821.400 2) 7821.410 7821.440 2) 7821.500 7821.510 7821.540 2) 7821.600 7821.610<br />
at the front<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
3) Glazed aluminium door, delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
38 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, types 1 and 2<br />
T1<br />
B1<br />
T1<br />
B1<br />
H2<br />
B2<br />
H1<br />
H1<br />
<strong>Networking</strong><br />
T2<br />
Type 1<br />
Designer glazed door at the<br />
front (180°), with 3 mm singlepane<br />
safety glass, comfort<br />
handle for semi-cylinder and<br />
security lock 3524 E;<br />
sheet steel door at the rear<br />
(130°) with handle and security<br />
lock 3524 E.<br />
Type 2<br />
Sheet steel door at front (180°),<br />
with comfort handle for semicylinder<br />
and security lock<br />
3524 E;<br />
sheet steel door at the rear<br />
(130°) with handle and security<br />
lock 3524 E.<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure frame:<br />
Dipcoat-primed<br />
Doors and roof: Dipcoat-primed,<br />
powder-coated in RAL 7035<br />
Base plates and punched<br />
sections with mounting flanges:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
Enclosure frame with doors,<br />
roof plate, multi-piece gland<br />
plate, 2 punched sections with<br />
mounting flanges in the enclosure<br />
depth.<br />
Approvals,<br />
see page 402.<br />
Detailed drawing,<br />
available on the Internet.<br />
U 38 38 38 38 42 42 42 42 42<br />
Width (B1) mm 1) 600 800 800 800 600 600 600 600 800<br />
Height (H1) mm 1) 1800 1800 1800 1800 2000 2000 2000 2000 2000<br />
Depth (T1) mm 1) 900 600 800 1000 600 800 900 1000 600<br />
Clearance width (B2) mm 512 712 712 712 712 512 512 512 512<br />
Clearance height (H2) mm 1712 1712 1712 1712 1912 1912 1912 1912 1912<br />
Clearance depth (T2) mm 812 512 712 912 512 712 812 912 512<br />
Model No. DK,<br />
type 1 with designer glazed door<br />
at the front<br />
Model No. DK,<br />
type 2 with sheet steel door<br />
at the front<br />
7920.620 3) 7920.640 3) 7920.650 3) 7920.670 3) 7920.700 3) 7920.710 2)3) 7920.720 3) 7920.730 3) 7920.740 3)<br />
7821.620 2) 7821.640 2) 7821.650 7821.670 2) 7821.700 7821.710 2) 7821.720 7821.730 7821.740<br />
U 42 42 42 47 47 47 47 47 47<br />
Width (B1) mm 1) 800 800 800 600 600 800 800 800 800<br />
Height (H1) mm 1) 2000 2000 2000 2200 2200 2200 2200 2200 2200<br />
Depth (T1) mm 1) 800 900 1000 600 800 600 800 900 1000<br />
Clearance width (B2) mm 712 712 712 712 512 512 712 712 712<br />
Clearance height (H2) mm 1912 1912 1912 2112 2112 2112 2112 2112 2112<br />
Clearance depth (T2) mm 712 812 912 512 712 512 712 812 912<br />
Model No. DK,<br />
type 1 with designer glazed door 7920.750 3) 7920.760 3) 7920.770 3) 7920.800 3) 7920.810 3) 7920.840 3) 7920.850 3) 7920.860 3) 7920.870 3)<br />
at the front<br />
Model No. DK,<br />
type 2 with sheet steel door 7821.750 7821.760 7821.770 7821.800 7821.810 7821.840 2) 7821.850 7821.860 2) 7821.870<br />
at the front<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
3) Glazed aluminium door, delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
39
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 15 – 20 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Page<br />
<strong>Networking</strong><br />
U 15 20 20<br />
Width (B1) mm 1) 600 600 800<br />
Height (H1) mm 1) 800 1000 1000<br />
Depth (T1) mm 1) 600 600 600<br />
Model No. DK 7920.100 7821.100 7920.200 7821.200 7920.240 2) 7821.240 2)<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – –<br />
Sheet steel front door/sheet steel rear door – – – <br />
Various door options from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.086 7824.106 7824.106 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 266<br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8173.235 8174.235 8174.235 265<br />
Baying from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.766 7826.766 7826.786 293<br />
Roof plate for cable entry 7826.665 7826.665 7826.865 292<br />
Roof plate, vented, for cable entry 7826.669 7826.669 7826.869 293<br />
Fan mounting plate, active, with controller 7966.035 7966.035 7986.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.601 7825.601 7825.601 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.605 8601.605 8601.805 255<br />
Base/plinth trim panels, side, H = 100 mm 8601.065 8601.065 8601.065 255<br />
Gland plate variants from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, cranked<br />
(for network technology)<br />
7827.080 7827.100 7827.100 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technology)<br />
7827.081 7827.101 7827.101 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
– – –<br />
Depth stays for mounting angles 8612.060 8612.060 7827.600 299/369<br />
Installation brackets for mounting angles – – 7827.480 369<br />
Cable clamp rails see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1)<br />
All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252<br />
40 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 24 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 1 Type 2 Type 1 Page<br />
<strong>Networking</strong><br />
U 24 24 24 24 24<br />
Width (B1) mm 1) 600 800 800 800 800<br />
Height (H1) mm 1) 1200 1200 1200 1200 1200<br />
Depth (T1) mm 1) 600 600 800 900 1000<br />
Model No. DK 7920.300 7821.300 7920.340 2) 7821.340 7920.350 7920.355 7821.355 7920.360 2)<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – – <br />
Sheet steel front door/sheet steel rear<br />
door<br />
– – – – –<br />
Various door options from page 277 from page 277 from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.126 7824.126 7824.128 7824.129 7824.120 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 7824.500 – 266<br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 7824.510 – 266<br />
Side panel, screw-fastened, IP 55 8170.235 8170.235 8175.235 – 8176.235 265<br />
Baying from page 270 from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.766 7826.786 7826.788 7826.789 7826.780 293<br />
Roof plate for cable entry 7826.665 7826.865 7826.885 7826.895 7826.805 292<br />
Roof plate, vented, for cable entry 7826.669 7826.869 7826.889 7826.899 7826.809 293<br />
Fan mounting plate, active, with controller 7966.035 7986.035 7988.035 7988.035 7988.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.601 7825.801 7825.801 7825.801 7825.801 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.605 8601.805 8601.805 8601.805 8601.805 255<br />
Base/plinth trim panels, side, H = 100 mm 8601.065 8601.065 8601.085 8601.095 8601.015 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, cranked<br />
(for network technology)<br />
7827.120 7827.120 7827.120 7827.120 7827.120 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technlogy)<br />
7827.121 7827.121 7827.121 7827.121 7827.121 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
7856.713 7856.725 7856.725 7856.725 7856.725 366<br />
Depth stays for mounting angles 8612.060 7827.600 7827.800 7827.900 7827.000 299/369<br />
Installation brackets for mounting angles – 7827.480 7827.480 7827.480 7827.480 369<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252<br />
Rittal IT catalogue/<strong>Networking</strong><br />
41
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 29 – 33 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Page<br />
<strong>Networking</strong><br />
U 29 29 29 33<br />
Width (B1) mm 1) 600 600 800 600<br />
Height (H1) mm 1) 1400 1400 1400 1600<br />
Depth (T1) mm 1) 600 800 600 600<br />
Model No. DK 7920.400 2) 7821.400 2) 7920.410 7821.410 7920.440 2) 7821.440 2) 7920.500 7821.500<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – – –<br />
Sheet steel front door/sheet steel rear<br />
door<br />
– – – – <br />
Various door options from page 277 from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.146 7824.148 7824.146 7824.166 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 7824.500 266<br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8146.235 8148.235 8146.235 8166.235 265<br />
Baying from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.766 7826.768 7826.786 7826.766 293<br />
Roof plate for cable entry 7826.665 7826.685 7826.865 7826.665 292<br />
Roof plate, vented, for cable entry 7826.669 7826.689 7826.869 7826.669 293<br />
Fan mounting plate, active, with controller 7966.035 7968.035 7986.035 7966.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.601 7825.601 7825.801 7825.601 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.605 8601.605 8601.805 8601.605 255<br />
Base/plinth trim panels, side, H = 100 mm 8601.065 8601.085 8601.065 8601.065 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, cranked<br />
(for network technology)<br />
7827.140 7827.140 7827.140 7827.160 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technology)<br />
7827.141 7827.141 7827.141 7827.161 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
– – – –<br />
Depth stays for mounting angles 8612.060 8612.080 7827.600 8612.060 299/369<br />
Installation brackets for mounting angles – – 7827.480 – 369<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252<br />
42 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 33 – 38 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Page<br />
<strong>Networking</strong><br />
U 33 33 38 38<br />
Width (B1) mm 1) 600 800 600 600<br />
Height (H1) mm 1) 1600 1600 1800 1800<br />
Depth (T1) mm 1) 800 600 600 800<br />
Model No. DK 7920.510 7821.510 7920.540 2) 7821.540 2) 7920.600 7821.600 7920.610 7821.610<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – – –<br />
Sheet steel front door/sheet steel rear<br />
door<br />
– – – – <br />
Various door options from page 277 from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.168 7824.166 7824.186 7824.188 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 7824.500 266<br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8168.235 8166.235 8186.235 8188.235 265<br />
Baying from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.768 7826.786 7826.766 7826.768 293<br />
Roof plate for cable entry 7826.685 7826.865 7826.665 7826.685 292<br />
Roof plate, vented, for cable entry 7826.689 7826.869 7826.669 7826.689 293<br />
Fan mounting plate, active, with controller 7968.035 7986.035 7966.035 7968.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.601 7825.801 7825.601 7825.601 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.605 8601.805 8601.605 8601.605 255<br />
Base/plinth trim panels, side, H = 100 mm 8601.085 8601.065 8601.065 8601.085 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, cranked<br />
(for network technology)<br />
7827.160 7827.160 7827.180 7827.180 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technology)<br />
7827.161 7827.161 7827.181 7827.181 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
– – 7856.716 7856.716 366<br />
Depth stays for mounting angles 8612.080 7827.600 8612.060 8612.080 299/369<br />
Installation brackets for mounting angles – 7827.480 – – 369<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252<br />
Rittal IT catalogue/<strong>Networking</strong><br />
43
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 38 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Page<br />
<strong>Networking</strong><br />
U 38 38 38 38<br />
Width (B1) mm 1) 600 800 800 800<br />
Height (H1) mm 1) 1800 1800 1800 1800<br />
Depth (T1) mm 1) 900 600 800 1000<br />
Model No. DK 7920.620 7821.620 2) 7920.640 7821.640 2) 7920.650 7821.650 7920.670 7821.670 2)<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – – –<br />
Sheet steel front door/sheet steel rear<br />
door<br />
– – – – <br />
Various door options from page 277 from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.189 7824.186 7824.188 7824.180 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 7824.500 266<br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8189.235 8186.235 8188.235 8180.235 265<br />
Baying from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.769 7826.786 7826.788 7826.780 293<br />
Roof plate for cable entry 7826.695 7826.865 7826.885 7826.805 292<br />
Roof plate, vented, for cable entry 7826.699 7826.869 7826.869 7826.809 293<br />
Fan mounting plate, active, with controller 7968.035 7986.035 7988.035 7988.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.601 7825.801 7825.801 7825.801 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.605 8601.805 8601.805 8601.805 255<br />
Base/plinth trim panels, side<br />
H = 100 mm<br />
8601.095 8601.065 8601.085 8601.015 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, cranked<br />
(for network technology)<br />
7827.180 7827.180 7827.180 7827.180 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technology)<br />
7827.181 7827.181 7827.181 7827.181 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
7856.716 7856.728 7856.728 7856.728 366<br />
Depth stays for mounting angles 8612.090 7827.600 7827.800 7827.000 299/369<br />
Installation brackets for mounting angles – 7827.480 7827.480 7827.480 369<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252<br />
44 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 42 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Page<br />
<strong>Networking</strong><br />
U 42 42 42 42 42<br />
Width (B1) mm 1) 600 600 600 600 800<br />
Height (H1) mm 1) 2000 2000 2000 2000 2000<br />
Depth (T1) mm 1) 600 800 900 1000 600<br />
Model No. DK 7920.700 7821.700 7920.710 7821.710 7920.720 7821.720 7920.730 7821.730 7920.740 7821.740<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – – – –<br />
Sheet steel front door/<br />
sheet steel rear door<br />
– – – – – <br />
Various door options from page 277 from page 277 from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.206 7824.208 7824.209 7824.200 7824.206 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 7824.500 7824.500 266<br />
Internal latch for side panel, plug-in 7824.510 7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8106.235 8108.235 8109.235 8100.235 8106.235 265<br />
Baying from page 270 from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.766 7826.768 7826.769 7826.760 7826.786 293<br />
Roof plate for cable entry 7826.665 7826.685 7826.695 7826.605 7826.865 292<br />
Roof plate, vented,<br />
for cable entry<br />
7826.669 7826.689 7826.699 7826.609 7826.869 293<br />
Fan mounting plate, active,<br />
with controller<br />
7966.035 7968.035 7968.035 7968.035 7986.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.601 7825.601 7825.601 7825.601 7825.801 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.605 8601.605 8601.605 8601.605 8601.805 255<br />
Base/plinth trim panels, side<br />
H = 100 mm<br />
8601.065 8601.085 8601.095 8601.015 8601.065 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles,<br />
cranked (for network technology)<br />
7827.200 7827.200 7827.200 7827.200 7827.200 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technology)<br />
7827.201 7827.201 7827.201 7827.201 7827.201 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
7856.719 7856.719 7856.719 7856.719 7856.731 366<br />
Depth stays for mounting angles 8612.060 8612.080 8612.090 8612.000 7827.600 299/369<br />
Installation brackets<br />
for mounting angles<br />
– – – – 7827.480 369<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
Accessories Page 252<br />
Rittal IT catalogue/<strong>Networking</strong><br />
45
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 42 – 47 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Page<br />
<strong>Networking</strong><br />
U 42 42 42 47 47<br />
Width (B1) mm 1) 800 800 800 600 600<br />
Height (H1) mm 1) 2000 2000 2000 2200 2200<br />
Depth (T1) mm 1) 800 900 1000 600 800<br />
Model No. DK 7920.750 7821.750 7920.760 7821.760 7920.770 7821.770 7920.800 7821.800 7920.810 7821.810<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – – – –<br />
Sheet steel front door/<br />
sheet steel rear door<br />
– – – – – <br />
Various door options from page 277 from page 277 from page 277 from page 277 from page 277<br />
180° hinges<br />
for sheet steel rear door<br />
8800.190 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.208 7824.209 7824.200 7824.226 7824.228 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 7824.500 7824.500 266<br />
Internal latch<br />
for side panel, plug-type<br />
7824.510 7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8108.235 8109.235 8100.235 8126.235 8128.235 265<br />
Baying from page 270 from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.788 7826.789 7826.780 7826.766 7826.768 293<br />
Roof plate for cable entry 7826.885 7826.895 7826.805 7826.665 7826.685 292<br />
Roof plate, vented,<br />
for cable entry<br />
7826.889 7826.899 7826.809 7826.669 7826.689 293<br />
Fan mounting plate, active,<br />
with controller<br />
7988.035 7988.035 7988.035 7966.035 7968.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.801 7825.801 7825.801 7825.601 7825.601 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.805 8601.805 8601.805 8601.605 8601.605 255<br />
Base/plinth trim panels, side<br />
H = 100 mm<br />
8601.085 8601.095 8601.015 8601.065 8601.085 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles,<br />
cranked (for network technology)<br />
7827.200 7827.200 7827.200 7827.220 7827.220 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technology)<br />
7827.201 7827.201 7827.201 7827.221 7827.221 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
7856.731 7856.731 7856.731 7856.722 7856.722 366<br />
Depth stays for mounting angles 7827.800 7827.900 7827.000 8612.060 8612.080 299/369<br />
Installation brackets<br />
for mounting angles<br />
7827.480 7827.480 7827.480 – – 369<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
Accessories Page 252<br />
46 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal TS 8, 47 U<br />
Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 Type 2 Page<br />
<strong>Networking</strong><br />
U 47 47 47 47<br />
Width (B1) mm 1) 800 800 800 800<br />
Height (H1) mm 1) 2200 2200 2200 2200<br />
Depth (T1) mm 1) 600 800 900 1000<br />
Model No. DK 7920.840 7821.840 2) 7920.850 7821.850 7920.860 7821.860 2) 7920.870 7821.870<br />
Doors<br />
Designer glazed front door/<br />
sheet steel rear door<br />
– – – –<br />
Sheet steel front door/sheet steel rear<br />
door<br />
– – – – <br />
Various door options from page 277 from page 277 from page 277 from page 277<br />
180° hinges for sheet steel rear door 8800.190 8800.190 8800.190 8800.190 288<br />
Side panel<br />
Side panel, plug-in, IP 20 7824.226 7824.228 7824.229 7824.220 266<br />
Lock for side panel, plug-in, 3524 E 7824.500 7824.500 7824.500 7824.500 266<br />
Internal latch<br />
for side panel, plug-type<br />
7824.510 7824.510 7824.510 7824.510 266<br />
Side panel, screw-fastened, IP 55 8126.235 8128.235 8129.235 – 265<br />
Baying from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Solid roof plate <br />
Roof plate, vented 7826.786 7826.788 7826.789 7826.780 293<br />
Roof plate for cable entry 7826.865 7826.885 7826.895 7826.805 292<br />
Roof plate, vented, for cable entry 7826.869 7826.889 7826.899 7826.809 293<br />
Fan mounting plate, active, with controller 7986.035 7988.035 7988.035 7988.035 127<br />
Fan roof, modular see page 128 see page 128 see page 128 see page 128<br />
Spacers, 20 mm 2423.000 2423.000 2423.000 2423.000 293<br />
Spacers, 50 mm 7967.000 7967.000 7967.000 7967.000 293<br />
Climate control see page 123 see page 123 see page 123 see page 123<br />
Base/plinth<br />
Base/plinth components, vented,<br />
front and rear, H = 100 mm<br />
7825.801 7825.801 7825.801 7825.801 255<br />
Base/plinth components, solid,<br />
front and rear, H = 100 mm<br />
8601.805 8601.805 8601.805 8601.805 255<br />
Base/plinth trim panels, side<br />
H = 100 mm<br />
8601.065 8601.085 8601.095 8601.015 255<br />
Gland plate variants from page 263 from page 263 from page 263 from page 263<br />
Castors see page 256 see page 256 see page 256 see page 256<br />
Interior installation<br />
482.6 mm (19″) mounting angles, cranked<br />
(for network technology)<br />
7827.220 7827.220 7827.220 7827.220 364<br />
482.6 mm (19″) mounting angles,<br />
L-shaped (for server technlogy)<br />
7827.221 7827.221 7827.221 7827.221 364<br />
482.6 mm (19″) mounting frame<br />
(for server and network technology)<br />
7856.734 7856.734 7856.734 7856.734<br />
Depth stays for mounting angles 7827.600 7827.800 7827.900 7827.000 299/369<br />
Installation brackets for mounting angles 7827.480 7827.480 7827.480 7827.480 369<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2)<br />
Delivery times available on request.<br />
Accessories Page 252<br />
Rittal IT catalogue/<strong>Networking</strong><br />
47
<strong>Networking</strong><br />
Network enclosures, based on Rittal flexRack(i), pre-configured<br />
T1<br />
B1<br />
<strong>Networking</strong><br />
B2<br />
H2<br />
H1<br />
T2<br />
H2<br />
Material:<br />
Vertical frame sections:<br />
Extruded aluminium section<br />
Base, roof frame, base/plinth,<br />
panels: Sheet steel<br />
Surface finish:<br />
Enclosure panels:<br />
Spray-finished in RAL 7035<br />
Frame sections and doors:<br />
RAL 9006<br />
Lock panels: RAL 7035<br />
Viewing window: Tinted, grey<br />
Gland plates, 482.6 mm (19″)<br />
mounting angles:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
Multi-platform frame FR(i) with<br />
designer glazed door at front<br />
(130°), TS sheet steel door at<br />
rear (130°).<br />
Roof plate, side panels, vented<br />
base/plinth, gland plate, interior<br />
installation depending on<br />
design, see table on page 49.<br />
Earthing of all enclosure panels,<br />
comfort handle for semi-cylinders<br />
at the front, swivel handle<br />
at the rear, with security lock<br />
3524 E.<br />
Property rights:<br />
German patent no. 103 11 376<br />
German Registered Design<br />
no. 403 04 312<br />
British Registered Design<br />
no. 301 54 31<br />
Detailed drawing,<br />
available on the Internet.<br />
U 11 11 24 42 42<br />
Width (B1) mm 1) 600 600 600 800 800<br />
Height (H1 + H2) mm 1) 600 600 1200 2000 + 100 2000 + 100<br />
Depth (T1) mm 1) 805 1005 1005 805 1005<br />
Depth absolute, including handles and roof curvature<br />
(T1) mm + 74.5 mm<br />
879.5 1079.5 1079.5 879.5 1079.5<br />
Model No. FR(i) as single enclosure including 2 side panels 7855.480 7855.500 7855.510 7855.550 7855.570<br />
Model No. FR(i) as bayed enclosure without side panels,<br />
including baying kit<br />
– – – 7855.540 7855.560 2)<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
48 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures, based on Rittal flexRack(i), pre-configured<br />
<strong>Networking</strong><br />
U 11 11 24 42 42 Page<br />
Width (B1) mm 1) 600 600 600 800 800<br />
Height (H1 + H2) mm 1) 600 600 1200 2000 + 100 2000 + 100<br />
Depth (T1) mm 1) 805 1005 1005 805 1005<br />
Depth absolute, including handles and roof curvature<br />
(T1) mm + 74.5 mm<br />
Model No. FR(i) as single enclosure<br />
including 2 side panels<br />
Model No. FR(i) as bayed enclosure<br />
without side panels, including baying kit<br />
879.5 1079.5 1079.5 879.5 1079.5<br />
7855.480 7855.500 7855.510 7855.550 7855.570<br />
– – – 7855.540 7855.560 2)<br />
Doors<br />
Designer glazed front door/TS sheet steel rear door <br />
Side panel<br />
Side panel, plug-type<br />
<br />
<br />
<br />
including security lock 3524 E<br />
(7855.550 only) (7855.570 only)<br />
266<br />
Internal latch for side panel, plug-in 266<br />
Baying from page 270 from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Designer roof plate, solid – –<br />
Designer roof plate for cable entry, two-piece – – – <br />
Various roof plate options, based on TS 8 from page 292 from page 292 from page 292 from page 292 from page 292<br />
Base/plinth<br />
Base/plinth components solid, front and rear 8601.605 8601.605 8601.605 8601.805 8601.805 255<br />
Base/plinth components, vented, front and rear 7825.601 7825.601 7825.601 255<br />
Base/plinth trim, side 8601.085 8601.015 8601.015 255<br />
Base/gland plate, mounted at front as infill panel,<br />
rear part open<br />
– – – <br />
Gland plate, one-piece, vented – – 263<br />
Gland plate variants, based on TS 8 from page 263 from page 263 from page 263 from page 263 from page 263<br />
Interior installation<br />
482.6 mm (19″) mounting angles, L-shaped at front – – 364<br />
Additional 482.6 mm (19″) mounting angles, L-shaped 7856.800 7856.800 7856.803 7856.809 7856.809 364<br />
482.6 mm (19″) mounting frames, front and rear – – – 366<br />
Additional 482.6 mm (19″) mounting frame 7856.710 7856.710 7856.713 7856.719 7856.719 366<br />
System punched section, interior installation of rail systems from page 364 from page 364 from page 364 from page 364 from page 364<br />
Cable clamp rails see page 307 see page 307 see page 307 see page 307 see page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364 from page 364<br />
4 hammerhead rails including system adaptor,<br />
supplied loose, for cable clamping in the enclosure depth<br />
– – – <br />
10 cable shunting rings 105 x 70 mm, supplied loose – – – 355<br />
50 cage nuts and hexagon socket screws, supplied loose – – – 314<br />
Cable management from page 341 from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2)<br />
Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
49
<strong>Networking</strong><br />
Network enclosures based on Rittal flexRack(i)<br />
T1<br />
B1<br />
<strong>Networking</strong><br />
H1<br />
Material:<br />
Vertical frame sections:<br />
Extruded aluminium section<br />
Base, roof frame, panels:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure panels:<br />
Spray-finished in RAL 7035<br />
Frame sections and doors:<br />
RAL 9006<br />
Lock panels: RAL 7035<br />
Viewing window: Tinted, grey<br />
Gland plates: Zinc-plated,<br />
passivated<br />
Supply includes:<br />
Multi-platform frame FR(i) with<br />
designer glazed front door<br />
(130°), TS sheet steel rear door<br />
(130°), solid roof plate, multipiece<br />
gland plate, levelling feet,<br />
comfort handle for semi-cylinder<br />
at the front, swivel handle<br />
at the rear, with security lock<br />
3524 E.<br />
Property rights:<br />
German patent no. 103 11 376<br />
German Registered Design<br />
no. 403 04 312<br />
British Registered Design<br />
no. 301 54 31<br />
Detailed drawing,<br />
available on the Internet.<br />
U 11 11 24 24 38 42 42 47<br />
Width (B1) mm 1) 600 600 600 600 600 600 600 600<br />
Height (H1) mm 1) 600 600 1200 1200 1800 2000 2000 2200<br />
Depth (T1) mm 1) 605 1005 605 1005 605 605 1005 1005<br />
Depth absolute, including<br />
handles and roof curvature<br />
679.5 1079.5 679.5 1079.5 679.5 679.5 1079.5 1079.5<br />
(T1) mm + 74.5 mm<br />
Model No. FR(i) 7855.610 2) 7855.620 2) 7855.630 2) 7855.640 2) 7855.650 2) 7855.660 2) 7855.670 2) 7855.680 2)<br />
U 24 38 42 42 47 47<br />
Width (B1) mm 1) 800 800 800 800 800 800<br />
Height (H1) mm 1) 1200 1800 2000 2000 2200 2200<br />
Depth (T1) mm 1) 805 805 805 1005 805 1005<br />
Depth absolute, including<br />
handles and roof curvature<br />
879.5 879.5 879.5 1079.5 879.5 1079.5<br />
(T1) mm + 74.5 mm<br />
Model No. FR(i) 7855.690 2) 7855.700 2) 7855.710 7855.720 7855.730 2) 7855.740 2)<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet. 2) Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
50 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Network enclosures based on Rittal flexRack(i)<br />
<strong>Networking</strong><br />
U 11 11 24 24 38 42 42 47 Page<br />
Width (B1) mm 1) 600 600 600 600 600 600 600 600<br />
Height (H1) mm 1) 600 600 1200 1200 1800 2000 2000 2200<br />
Depth (T1) mm 1) 605 1005 605 1005 605 605 1005 1005<br />
Depth absolute, including<br />
handles and roof curvature 679.5 1079.5 679.5 1079.5 679.5 679.5 1079.5 1079.5<br />
(T1) mm + 74.5 mm<br />
Model No. FR(i) 7855.610 2) 7855.620 2) 7855.630 2) 7855.640 2) 7855.650 2) 7855.660 2) 7855.670 2) 7855.680 2)<br />
Doors<br />
Designer glazed front door/<br />
TS sheet steel rear door<br />
<br />
Side panel<br />
Side panel, plug-type,<br />
including security lock 3524 E<br />
7856.660 7856.663 7856.666 7856.672 7856.675 7856.681 7856.687 7856.696 266<br />
Internal latch<br />
for side panel, plug-type<br />
7856.700 7856.700 7856.700 7856.700 7856.700 7856.700 7856.700 7856.700 266<br />
Baying from p. 270 from p. 270 from p. 270 from p. 270 from p. 270 from p. 270 from p. 270 from p. 270<br />
Roof<br />
Designer roof plate, solid <br />
Various roof plate options,<br />
based on TS 8<br />
from p. 292 from p. 292 from p. 292 from p. 292 from p. 292 from p. 292 from p. 292 from p. 292<br />
Base/plinth<br />
Base/plinth components, solid,<br />
front and rear<br />
8601.605 8601.605 8601.605 8601.605 8601.605 8601.605 8601.605 8601.605 255<br />
Base/plinth components, vented,<br />
front and rear<br />
7825.601 7825.601 7825.601 7825.601 7825.601 7825.601 7825.601 7825.601 255<br />
Base/plinth trim, side 8601.065 8601.015 8601.065 8601.015 8601.065 8601.065 8601.015 8601.015 255<br />
Gland plate, multi-piece <br />
Gland plate variants,<br />
based on TS 8<br />
from p. 263 from p. 263 from p. 263 from p. 263 from p. 263 from p. 263 from p. 263 from p. 263<br />
Interior installation<br />
482.6 mm (19″) mounting angles,<br />
L-shaped<br />
7856.800 7856.800 7856.803 7856.803 7856.806 7856.809 7856.809 7856.812 364<br />
482.6 mm (19″) mounting frame 7856.710 7856.710 7856.713 7856.713 7856.716 7856.719 7856.719 7856.722 366<br />
Punched sections with mounting<br />
flanges, interior installation, from p. 364 from p. 364 from p. 364 from p. 364 from p. 364 from p. 364 from p. 364 from p. 364<br />
rail systems<br />
Cable clamp rails from p. 307 from p. 307 from p. 307 from p. 307 from p. 307 from p. 307 from p. 307 from p. 307<br />
Earthing/potential equalisation from p. 337 from p. 337 from p. 337 from p. 337 from p. 337 from p. 337 from p. 337 from p. 337<br />
Socket strips/<br />
power management<br />
from p. 328 from p. 328 from p. 328 from p. 328 from p. 328 from p. 328 from p. 328 from p. 328<br />
Component shelves from p. 316 from p. 316 from p. 316 from p. 316 from p. 316 from p. 316 from p. 316 from p. 316<br />
19″ installation system from p. 364 from p. 364 from p. 364 from p. 364 from p. 364 from p. 364 from p. 364 from p. 364<br />
Cable management from p. 341 from p. 341 from p. 341 from p. 341 from p. 341 from p. 341 from p. 341 from p. 341<br />
CMC-TC system monitoring from p. 158 from p. 158 from p. 158 from p. 158 from p. 158 from p. 158 from p. 158 from p. 158<br />
Included with the supply.<br />
1)<br />
All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2) Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
Rittal IT catalogue/<strong>Networking</strong><br />
51
<strong>Networking</strong><br />
Network enclosures based on Rittal flexRack(i)<br />
<strong>Networking</strong><br />
U 24 38 42 42 47 47 Page<br />
Width (B1) mm 1) 800 800 800 800 800 800<br />
Height (H1) mm 1) 1200 1800 2000 2000 2200 2200<br />
Depth (T1) mm 1) 805 805 805 1005 805 1005<br />
Depth absolute, including handles and<br />
roof curvature (T1) mm + 74.5 mm<br />
879.5 879.5 879.5 1079.5 879.5 1079.5<br />
Model No. FR(i) 7855.690 2) 7855.700 2) 7855.710 7855.720 7855.730 2) 7855.740 2)<br />
Doors<br />
Designer glazed front door/TS sheet steel rear door <br />
Side panel<br />
Side panel, plug-type<br />
including security lock 3524 E<br />
7856.669 7856.678 7856.684 7856.687 7856.693 7856.696 266<br />
Internal latch for side panel, plug-in 7856.700 7856.700 7856.700 7856.700 7856.700 7856.700 266<br />
Baying from page 270 from page 270 from page 270 from page 270 from page 270 from page 270<br />
Roof<br />
Designer roof plate, solid <br />
Various roof plate options, based on TS 8 from page 292 from page 292 from page 292 from page 292 from page 292 from page 292<br />
Base/plinth<br />
Base/plinth components solid, front and rear 8601.805 8601.805 8601.805 8601.805 8601.805 8601.805 255<br />
Base/plinth components, vented, front and rear 7825.801 7825.801 7825.801 7825.801 7825.801 7825.801 255<br />
Base/plinth trim, side 8601.085 8601.085 8601.085 8601.015 8601.085 8601.015 255<br />
Gland plate, multi-piece <br />
Gland plate variants, based on TS 8 from page 263 from page 263 from page 263 from page 263 from page 263 from page 263<br />
Interior installation<br />
482.6 mm (19″) mounting frame 7856.725 7856.728 7856.731 7856.731 7856.734 7856.734 366<br />
System punched section, interior installation of rail<br />
systems<br />
from page 364 from page 364 from page 364 from page 364 from page 364 from page 364<br />
Cable clamp rails from page 307 from page 307 from page 307 from page 307 from page 307 from page 307<br />
Earthing/potential equalisation from page 337 from page 337 from page 337 from page 337 from page 337 from page 337<br />
Socket strips/power management from page 328 from page 328 from page 328 from page 328 from page 328 from page 328<br />
Component shelves from page 316 from page 316 from page 316 from page 316 from page 316 from page 316<br />
19″ installation system from page 364 from page 364 from page 364 from page 364 from page 364 from page 364<br />
Cable management from page 341 from page 341 from page 341 from page 341 from page 341 from page 341<br />
CMC-TC system monitoring from page 158 from page 158 from page 158 from page 158 from page 158 from page 158<br />
Included with the supply.<br />
1)<br />
All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
2)<br />
Delivery times available on request.<br />
Accessories Page 252 Monitoring Page 187 Climate control Page 113<br />
52 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
RNC enclosure<br />
T1<br />
T2<br />
B<br />
H<br />
<strong>Networking</strong><br />
Rittal-Net.com is the passive<br />
platform for the fast, futureproof<br />
assembly of communications<br />
networks in the small<br />
office sector.<br />
Three enclosures, for installation<br />
of connection cables, patch<br />
cables and distributor panels,<br />
are tailored to the specific criteria<br />
of the SOHO market. Work<br />
groups may be set up quickly<br />
and easily.<br />
Material:<br />
1.5 mm sheet steel<br />
Smoked grey acrylic glazing<br />
Corner sections, aluminium<br />
Corner feet made from thermoplastic<br />
foam<br />
Colour:<br />
Enclosure panels: RAL 7035<br />
Corner sections: RAL 7030<br />
Detailed drawing,<br />
available on the Internet.<br />
U Packs of 4 8 6 Page<br />
Width (B) mm 342 342 342<br />
Height (H) mm 215 390 490<br />
Depth (T1) mm 280 280 400<br />
Max. installation depth (T2) mm 250 250 335<br />
Model No. DK empty enclosure, individual 1 7870.100 7870.200 7870.300<br />
Design<br />
42 HP<br />
( 1 / 2 19″)<br />
42 HP<br />
( 1 / 2 19″)<br />
Installation position horizontal horizontal vertical<br />
Accessory kits<br />
Data distributor, including patch cable<br />
VF Cat 5, 8 ports, STP, LSA, including 8 patch cables with RJ 45 connector<br />
on both sides, extruded insulation, cable design in yellow, cable length 0.25 m<br />
VF Cat 6, 24 ports, STP, LSA, including 12 patch cables with RJ 45 connector<br />
on both sides, extruded insulation, cable design in yellow, cable length 0.6 m<br />
1)<br />
Delivery times available on request.<br />
84 HP<br />
(19″)<br />
1 7870.822 1) 7870.822 1) – 388<br />
1 – – 7870.830 388<br />
Accessories Page 55<br />
Rittal IT catalogue/<strong>Networking</strong><br />
53
<strong>Networking</strong><br />
RNC universal enclosure<br />
T1<br />
B<br />
<strong>Networking</strong><br />
T2<br />
H<br />
A compact contemporary<br />
design in black, with integral<br />
glazed door (tinted safety<br />
glass). Centered lock, the side<br />
panels cannot be removed<br />
whilst the front door is latched.<br />
Suitable for use as a stand-alone<br />
model and for wall mounting.<br />
The plug-in side panels ensure<br />
rapid access and plenty of<br />
scope when mounting. Optional<br />
1 / 2 19″, 10″ or 19″ components<br />
RNC can be bayed, both horizontally<br />
and vertically, using the<br />
connector kit (supplied loose).<br />
Passive ventilation via openings<br />
in the rear frame, roof and the<br />
gland plate. Fan expansion kit,<br />
optional (DK 7980.100).<br />
Cable entry optionally via the<br />
rear panel, roof or base.<br />
All frame parts and panels are<br />
prepared for earthing.<br />
Material:<br />
Sheet steel, single-pane safety<br />
glass<br />
Colour:<br />
Black, similar to RAL 9011<br />
Supply includes:<br />
Enclosure with glazed door,<br />
baying kit,<br />
brush strips for cable entry,<br />
482.6 mm (19″) mounting level<br />
at front.<br />
Property rights:<br />
German patents<br />
No. 10 210 481<br />
No. 10 210 482<br />
Detailed drawing,<br />
available on the Internet.<br />
U 269.2 mm ( 1 / 2 19″) Packs of 10 Page<br />
U 482.6 mm (19″) 5<br />
Width (B) mm 350<br />
Height (H) mm 500<br />
Depth (T1) mm 350<br />
Max. installation depth (T2) mm 270<br />
Model No. DK 1 7870.350<br />
Accessories<br />
Socket strip 3-way, without switch 1 7240.110 328<br />
Socket strip 7-way, without switch, for 482.6 mm (19″) level 1 7240.210 328<br />
Socket strip 7-way, with switch, for 482.6 mm (19″) level 1 7240.220 328<br />
1 / 2 19″ component shelf, 1 U 1 7502.600 323<br />
1<br />
/ 2 19″ cable management panel, 1 U 1 7502.610 56<br />
1 / 2 19″ blanking panel, 1 U 2 7870.720 55<br />
1 / 2 19″ cable entry panel, 1 U 2 7870.730 56<br />
19″ blanking panel, 1 U 2 7151.035 392<br />
19″ blanking panel, 2 U 2 7152.035 392<br />
19″ blanking panel, 3 U 2 7153.035 392<br />
Combination rail, length 200 mm 6 7502.302 352<br />
Adaptor for 10″ system, 1 U 1 7870.760 56<br />
Adaptor for 10″ system, 4 U 1 7870.765 56<br />
Phillips-head screw M5, with plastic washer 100 2099.500 382<br />
Phillips-head screw M6, with plastic washer 100 2089.000 382<br />
Captive nuts M5, with contact 50 2094.500 381<br />
Captive nuts M6, with contact 50 2094.200 381<br />
Data distributors Page 57<br />
54 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Accessories for RNC enclosures<br />
Base/plinth<br />
for RNC<br />
To accommodate a maximum of two 3-way socket<br />
strips DK 7240.110 and also as storage space for<br />
cables.<br />
Height: 60 mm.<br />
Material:<br />
Sheet steel<br />
Colour:<br />
RAL 7035<br />
Supply includes:<br />
4 levelling feet and 2/4 cable shunting rings.<br />
For RNC enclosures<br />
42 HP ( 1 / 2 19″) Model No. DK<br />
Width mm Depth mm<br />
342 280 7870.710 1)<br />
For RNC tower enclosures<br />
84 HP (19″) vertical Model No. DK<br />
Width mm Depth mm<br />
342 400 7870.715 1)<br />
1)<br />
Delivery times available on request.<br />
Accessories:<br />
Socket strip,<br />
see page 328.<br />
<strong>Networking</strong><br />
Angle bracket<br />
for RNC<br />
With space for optimum cable routing behind the<br />
RNC.<br />
Material:<br />
Sheet steel<br />
Colour:<br />
RAL 7035<br />
Supply includes:<br />
Assembly parts<br />
For RNC enclosures<br />
42 HP ( 1 / 2 19″) Packs<br />
of<br />
Width<br />
mm<br />
Depth<br />
mm<br />
Model No. DK<br />
342 280 2 7870.701<br />
For RNC tower enclosures<br />
84 HP (19″) vertical Packs<br />
of<br />
Width<br />
mm<br />
Depth<br />
mm<br />
Model No. DK<br />
342 400 2 7870.706<br />
Blanking panel 1 U,<br />
42 HP ( 1 / 2 19″)<br />
for RNC and RiCase<br />
As an extension cover.<br />
Material:<br />
Sheet steel<br />
Colour:<br />
RAL 7035<br />
Packs of<br />
Model No. DK<br />
2 7870.720<br />
Rittal IT catalogue/<strong>Networking</strong><br />
55
<strong>Networking</strong><br />
Accessories for RNC enclosures<br />
<strong>Networking</strong><br />
Cable management panel 1U<br />
42 HP ( 1 / 2 19″)<br />
for RNC<br />
For horizontal cable routing.<br />
Material:<br />
Sheet steel<br />
Colour:<br />
RAL 7035<br />
Supply includes:<br />
Tray and 5 shunting rings.<br />
U<br />
Model No. DK<br />
1 7502.610<br />
Entry panel 1 U<br />
42 HP ( 1 / 2 19″)<br />
for RNC<br />
For entry of patch cables. Cut-out approximately<br />
227 x 30 mm.<br />
Material:<br />
Sheet steel<br />
Colour:<br />
RAL 7035<br />
Packs of<br />
Model No. DK<br />
2 7870.730<br />
Adaptor<br />
for RNC<br />
For installing 10″ components in 296.2 mm<br />
( 1 / 2 19″) enclosures.<br />
Material:<br />
Sheet steel<br />
Colour:<br />
RAL 7035<br />
U<br />
Model No. DK<br />
1 7870.760<br />
4 7870.765<br />
56 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal QuickBox, 6 – 12 U<br />
T2<br />
B2<br />
T1<br />
B1<br />
H1<br />
H1<br />
H2<br />
T1<br />
B1<br />
<strong>Networking</strong><br />
Perfect access during installation<br />
and servicing, thanks to a<br />
removable cover.<br />
Material:<br />
Wall mounting plate with<br />
mounting brackets:<br />
2.0 mm sheet steel<br />
Enclosure cover:<br />
1.0 mm sheet steel<br />
Door: Sheet steel door or glazed<br />
door with sheet steel frame and<br />
single-pane safety glass, 3 mm<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Supply includes:<br />
Wall section:<br />
Pre-configured mounting<br />
bracket,<br />
brush strip for cable entry at the<br />
bottom/top,<br />
cable clamp rail<br />
Enclosure cover:<br />
consisting of base and cover<br />
tray with vent slots, brush strip<br />
for cable entry at the top/bottom,<br />
2 side security locks, sheet steel<br />
door/glazed door with security<br />
lock, 482.6 mm (19″) mounting<br />
angles, infinitely depth-variable.<br />
Property rights:<br />
German patent<br />
No. 198 11 711<br />
German utility model<br />
No. 298 23 843<br />
European patent no. 1 064 709<br />
with validity for BE, ES, FR, GB,<br />
IT, NL, SE<br />
Taiwanese patent<br />
No. NI 123 288<br />
Russian patent no. 2190912<br />
Australian patent<br />
No. 733078<br />
South Korean patent<br />
No. 10-0375062<br />
US patent no. 6,435,364<br />
Detailed drawing,<br />
available on the Internet.<br />
U P. of 6 6 6 9 9 12 12 12 Page<br />
Enclosure cover<br />
Wall section<br />
Width (B1) mm 600 600 600 600 600 600 600 600<br />
Height (H1) mm 362 362 362 495 495 628 628 628<br />
Depth (T1) mm 300 400 600 400 600 400 500 600<br />
Width (B2) mm 595 595 595 595 595 595 595 595<br />
Height (H2) mm 355 355 355 488 488 621 621 621<br />
Max. installation depth (T2) mm 247 347 547 347 547 347 447 547<br />
Model No. with glazed door 1 7502.013 7502.014 7502.016 7502.024 7502.026 7502.034 7502.035 7502.036<br />
Model No. with sheet steel door 1 – 7502.114 – 7502.124 7502.126 – – 7502.136<br />
Accessories<br />
Mounting angles, 482.6 mm (19″) 2 7502.201 7502.201 7502.201 7502.202 7502.202 7502.203 7502.203 7502.203 365<br />
Solid gland plate 2 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 346<br />
Wall mounting bracket, 10 mm 4 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 294<br />
Wall mounting bracket, 40 mm 4 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 294<br />
Combination rails for enclosure width 6 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 352<br />
Combination rails<br />
300/400 mm 7502.302 7502.302 7502.302 7502.302 7502.302 7502.302 7502.302 7502.302 352<br />
6<br />
for enclosure depth<br />
500/600 mm 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 352<br />
300 mm 10 1962.200 1962.200 1962.200 1962.200 1962.200 1962.200 1962.200 1962.200 377<br />
Slide rails<br />
400 mm<br />
7492.300 7492.300 7492.300 7492.300 7492.300 7492.300 7492.300 7492.300 383<br />
for enclosure depth<br />
2<br />
500/600 mm 7492.400 7492.400 7492.400 7492.400 7492.400 7492.400 7492.400 7492.400 383<br />
Earthing kit 1 7502.240 7502.240 7502.260 7502.240 7502.260 7502.240 7502.260 7502.260 339<br />
Quick-release fastener 2 7502.220 7502.220 7502.220 7502.220 7502.220 7502.220 7502.220 7502.220 288<br />
1) Delivery times available on request.<br />
Cable clamps<br />
for clamping to C rails and<br />
combination rails,<br />
see page 352.<br />
Splicing box<br />
for fibre-optic termination or<br />
fibre-optic distributor,<br />
see page 394.<br />
Accessories Page 252 Mounting angles Page 364 Wall mounting Page 290 Earthing Page 337<br />
Rittal IT catalogue/<strong>Networking</strong><br />
57
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal QuickBox, 15 – 21 U<br />
T2<br />
B2<br />
H1<br />
<strong>Networking</strong><br />
T1<br />
B1<br />
H1<br />
H2<br />
T1<br />
B1<br />
Perfect access during installation<br />
and servicing, thanks to a<br />
removable cover.<br />
Material:<br />
Wall mounting plate with<br />
mounting brackets:<br />
2.0 mm sheet steel<br />
Enclosure cover:<br />
1.0 mm sheet steel<br />
Door: Sheet steel door or glazed<br />
door with sheet steel frame and<br />
single-pane safety glass, 3 mm<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Supply includes:<br />
Wall section:<br />
Pre-configured mounting<br />
bracket,<br />
brush strip for cable entry at the<br />
bottom/top,<br />
cable clamp rail<br />
Enclosure cover:<br />
consisting of base and cover<br />
tray with vent slots, brush strip<br />
for cable entry at the top/bottom,<br />
2 side security locks, sheet steel<br />
door/glazed door with security<br />
lock, 482.6 mm (19″) mounting<br />
angles, infinitely depth-variable.<br />
Property rights:<br />
German patent<br />
No. 198 11 711<br />
German utility model<br />
No. 298 23 843<br />
European patent no. 1 064 709<br />
with validity for BE, ES, FR, GB,<br />
IT, NL, SE<br />
Taiwanese patent<br />
No. NI 123 288<br />
Russian patent no. 2190912<br />
Australian patent<br />
No. 733078<br />
South Korean patent<br />
No. 10-0375062<br />
US patent no. 6,435,364<br />
Detailed drawing,<br />
available on the Internet.<br />
U P. of 15 15 15 18 18 21 21 Page<br />
Enclosure cover<br />
Wall section<br />
Width (B1) mm 600 600 600 600 600 600 600<br />
Height (H1) mm 762 762 762 895 895 1028 1028<br />
Depth (T1) mm 400 500 600 400 600 400 600<br />
Width (B2) mm 595 595 595 595 595 595 595<br />
Height (H2) mm 755 755 755 888 888 1021 1021<br />
Max. installation depth (T2) mm 347 447 547 347 547 347 547<br />
Model No. with glazed door 1 7502.044 7502.045 7502.046 7502.054 7502.056 7502.064 7502.066<br />
Model No. with sheet steel door 1 7502.144 – 7502.146 – – – 7502.166<br />
Accessories<br />
Mounting angles, 482.6 mm (19″) 2 7502.204 7502.204 7502.204 7502.205 7502.205 7502.206 7502.206 365<br />
Solid gland plate 2 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 7502.310 1) 346<br />
Wall mounting bracket, 10 mm 4 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 294<br />
Wall mounting bracket, 40 mm 4 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 294<br />
Combination rails for enclosure width 6 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 352<br />
Combination rails<br />
300/400 mm 7502.302 7502.302 7502.302 7502.302 7502.302 7502.302 7502.302 352<br />
6<br />
for enclosure depth<br />
500/600 mm 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 7502.304 352<br />
Slide rails<br />
400 mm 2 7492.300 7492.300 7492.300 7492.300 7492.300 7492.300 7492.300 383<br />
for enclosure depth<br />
500/600 mm 2 7492.400 7492.400 7492.400 7492.400 7492.400 7492.400 7492.400 383<br />
Earthing kit 1 7502.240 7502.260 7502.260 7502.240 7502.260 7502.240 7502.260 339<br />
Quick-release fastener 2 7502.220 7502.220 7502.220 7502.220 7502.220 7502.220 7502.220 288<br />
1) Delivery times available on request.<br />
Cable management panel<br />
for all QuickBoxes from a height<br />
of 15 U,<br />
see page 358.<br />
Earthing kit<br />
for standardised earthing<br />
of the QuickBox. With fast-on<br />
connections,<br />
see page 339.<br />
Accessories Page 252 Cable routing Page 341 Lock systems Page 281 Patch panel Page 388<br />
58 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal QuickBox with vertical 482.6 mm (19″) level<br />
T2<br />
B2<br />
T1<br />
B1<br />
H1<br />
H2<br />
<strong>Networking</strong><br />
Optimum use of the interior<br />
space<br />
via side installation of the<br />
482.6 mm (19″) components.<br />
Status monitoring via side<br />
viewing window.<br />
Material:<br />
Wall mounting plate with<br />
mounting brackets:<br />
2.0 mm sheet steel<br />
Enclosure cover:<br />
1.0 mm sheet steel with<br />
toughened safety glass,<br />
3 mm at the side<br />
Supply includes:<br />
Wall section:<br />
with pre-configured 482.6 mm<br />
(19″) mounting brackets for side<br />
accommodation of mounting<br />
components and brush strip for<br />
cable entry from the bottom and<br />
top.<br />
Detailed drawing,<br />
available on the Internet.<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Enclosure cover:<br />
with side vent slots to support<br />
passive climate control. The<br />
enclosure is secured via two<br />
security locks positioned at the<br />
sides.<br />
U vertical Packs of 3 6 Page<br />
Enclosure cover<br />
Wall section<br />
Width (B1) mm 600 600<br />
Height (H1) mm 631 631<br />
Depth (T1) mm 210 360<br />
Width (B2) mm 595 595<br />
Height (H2) mm 621 621<br />
Depth (T2) mm 198 348<br />
Model No. DK 1 7502.630 1) 7502.660 1)<br />
Accessories<br />
Gland plates, solid 2 7502.310 1) 7502.310 1) 346<br />
Wall mounting bracket, 10 mm 4 2508.010 2508.010 294<br />
Wall mounting bracket, 40 mm 4 2503.010 2503.010 294<br />
Combination rails for vertical mounting on the wall section QB 6 7502.304 7502.304 352<br />
Combination rails for horizontal mounting 6 7502.304 7502.304 352<br />
Mounting and cable management panel<br />
for cable routing and the attachment of small equipment<br />
1 7502.270 7502.270 358<br />
Mounting angles, 482.6 mm (19″) for front mounting, 12 U 2 7502.203 7502.203 365<br />
1) Delivery times available on request.<br />
Blanking panel<br />
for toolless quick assembly<br />
see page 392.<br />
Wall mounting bracket<br />
at a distance of 10 mm or<br />
40 mm,<br />
see page 294.<br />
Accessories Page 252 Cable management Page 341 Gland plates Page 342 Earthing Page 337<br />
Rittal IT catalogue/<strong>Networking</strong><br />
59
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal AE<br />
T1<br />
B<br />
<strong>Networking</strong><br />
T2<br />
H<br />
Wall-mounted distributor with<br />
infinitely depth-variable<br />
482.6 mm (19″) mounting level<br />
at the front. The ideal solution for<br />
small networks or corridor distributors.<br />
Max. achievable protection<br />
category of up to IP 55 (to<br />
EN 60 529/10.91) by replacing<br />
the cable entry brush with a<br />
gland plate.<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Supply includes:<br />
1 wall-mounted distributor<br />
enclosure with sheet steel door,<br />
cam lock and double-bit insert.<br />
Brush strip for cable entry at the<br />
bottom,<br />
2 mounting angles, 482.6 mm<br />
(19″), depth-adjustable<br />
1 C rail for cable routing,<br />
1 metal bracket for optional<br />
accommodation of an earth rail<br />
or 482.6 mm (19″) socket strip.<br />
Available on request:<br />
● Fully modified wall-mounted<br />
distributors<br />
● Special designs<br />
Approvals,<br />
see page 402.<br />
Detailed drawing,<br />
available on the Internet.<br />
U Packs of 8 13 16 Page<br />
Width (B) mm 600 600 600<br />
Height (H) mm 380 600 760<br />
Depth (T1) mm 350 350 350<br />
Max. installation depth (T2) mm 310 310 310<br />
Model No. DK 1 7641.000 7643.000 7645.000<br />
Accessories<br />
Plastic cable gland plates with pre-punched PG holes 5 2563.000 2563.000 2563.000 342<br />
Metal gland plates with pre-punched metric holes 1 2563.100 2563.100 2563.100 344<br />
Wall mounting bracket, 10 mm 4 2508.010 2508.010 2508.010 294<br />
Wall mounting bracket, 40 mm 4 2503.010 2503.010 2503.010 294<br />
Glazed door, 34 mm profile depth 1 2730.000 2731.000 2732.000 280<br />
Glazed door, 60 mm profile depth 1 2760.000 2761.000 2762.000 280<br />
Component shelf 2 U, static installation, 250 mm 1 7119.250 7119.250 7119.250 323<br />
Earth rail 1 7113.000 7113.000 7113.000 338<br />
Lock systems<br />
Plastic handle, version B, see page 286.<br />
Standard double-bit lock insert may be exchanged for 27 mm lock inserts, type A, see page 285,<br />
Earth rail<br />
for attaching to the rear bracket,<br />
see page 338.<br />
High protection category<br />
by exchanging the brush strip<br />
for metal gland plates,<br />
see page 344.<br />
Accessories Page 252 Socket strips Page 328 Cage nuts Page 314 Glazed doors Page 280<br />
60 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Wall mounted enclosure, based on Rittal AE, with pull-out frame<br />
350<br />
600<br />
210<br />
450<br />
525<br />
600<br />
<strong>Networking</strong><br />
520<br />
Wall mounted distributor with<br />
482.6 mm (19″) pull-out frame.<br />
Side and front installation with<br />
482.6 mm (19″) components in<br />
a vertical mounting position.<br />
Horizontal installation also<br />
optionally supported at the front.<br />
Status monitoring via side viewing<br />
window. Pull-out frame may<br />
be removed for population via<br />
snap fastenings. Passive cooling<br />
via pre-configured outlet filter,<br />
may be upgraded to active.<br />
Optional accommodation of<br />
earth rail DK 7113.000 in a vertical<br />
position on the pull-out<br />
frame.<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Pull-out frame zinc-plated,<br />
passivated.<br />
Supply includes:<br />
1 wall-mounted distributor<br />
enclosure with sheet steel door,<br />
cam locks and double-bit insert.<br />
Pull-out frame attached to<br />
telescopic slides.<br />
Outlet filter in enclosure base<br />
and on left-hand side.<br />
Viewing window on right-hand<br />
side.<br />
Combination rail for cable<br />
clamping behind the cable<br />
entry. Additional cable clamp<br />
rail for mounting on the pull-out<br />
frame.<br />
Protection category:<br />
IP 43 to EN 60 529/10.91<br />
Available on request:<br />
● Fully modified wall-mounted<br />
distributors<br />
● Special designs<br />
Detailed drawing,<br />
available on the Internet.<br />
Width mm Packs of 600 Page<br />
Height mm 600<br />
Depth mm 350<br />
Model No. DK 1 7644.000<br />
Side 482.6 mm (19″) level, vertical<br />
4 U<br />
Front 482.6 mm (19″) level, vertical and horizontal<br />
10 U<br />
Accessories<br />
Plastic cable gland plates with pre-punched PG holes 5 2563.000 342<br />
Wall mounting bracket, 10 mm 4 2508.010 294<br />
Wall mounting bracket, 40 mm 4 2503.010 294<br />
Shelf 1 7644.400 1) 324<br />
Component shelf, 1 U 1 7119.140 322<br />
Earth rail, horizontal 1 7113.000 338<br />
Fan expansion kit 230 V AC (only for use at the bottom) 1 set 7980.100 127<br />
Fan expansion kit 48 V DC (only for use at the bottom) 1 set 7980.148 127<br />
Lock systems<br />
Plastic handle, version B, see page 286.<br />
Standard double-bit lock insert may be exchanged for 27 mm lock inserts, type A, see page 285.<br />
1) Delivery times available on request.<br />
Active ventilation<br />
with the fan expansion kit in<br />
230 V AC or 48 V DC versions,<br />
see page 127.<br />
Shelf<br />
a support surface for small<br />
equipment,<br />
see page 324.<br />
Accessories Page 252 Component shelf Page 324 Touch-up pens Page 269 Telecoms mounting bracket Page 230<br />
Rittal IT catalogue/<strong>Networking</strong><br />
61
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal EL, 3-part, pre-configured, depth 573<br />
H2<br />
H1<br />
<strong>Networking</strong><br />
T1<br />
T3 T2<br />
B1<br />
T4<br />
B2<br />
Material:<br />
Wall and hinged part:<br />
Sheet steel, 1.5 mm<br />
Viewing window:<br />
Toughened safety glass 3 mm<br />
Colour:<br />
Wall and hinged part:<br />
Powder-coated, RAL 7035<br />
Glazed door: RAL 7035/7015<br />
(slate grey)<br />
Protection category:<br />
IP 43 to EN 60 529/10.91 when<br />
using solid gland plates.<br />
Supply includes:<br />
Wall section:<br />
with vertical punched rails and<br />
C rail mounted horizontally for<br />
cable clamping, top cable gland<br />
plate solid, bottom cable gland<br />
plate with brush strips,<br />
earthing rail with star earthing,<br />
wall mounting bracket 10 mm.<br />
Hinged part:<br />
with 25 mm pitch pattern of<br />
holes in the front and rear frame,<br />
two 482.6 mm (19″) mounting<br />
angles mounted on C rails,<br />
infinitely depth-variable,<br />
one outlet filter each on the left<br />
and right side.<br />
Designer glazed door:<br />
with 3 mm toughened safety<br />
glass pane,<br />
9 + 15 U with mini comfort<br />
handle for lock inserts,<br />
21 U with comfort handle and<br />
2-point locking,<br />
including lock 3524 E.<br />
Available on request:<br />
● Fully modified wall-mounted<br />
distributors.<br />
● Glazed door with aluminium<br />
frame<br />
● Sheet steel door, solid<br />
● Perforated door<br />
Approvals,<br />
see page 403.<br />
Detailed drawing,<br />
available on the Internet.<br />
U Packs of 9 15 21 Page<br />
Width (B1) mm 600 600 600<br />
Height (H1) mm 478 746 1012<br />
Depth (T1) mm 573 573 573<br />
Clearance width (B2) mm 502 502 502<br />
Clearance height (H2) mm 417 684 951<br />
Depth of wall section (T2) mm 135 135 135<br />
Depth of hinged part (T3) mm 416 416 416<br />
Maximum installation depth (T4) mm 520 520 520<br />
Model No. DK 1 7709.735 7715.735 7721.735<br />
Load capacity, hinged part (kg) 45 75 75<br />
Accessories<br />
Solid gland plate 1 2235.135 2235.135 2235.135 346<br />
Gland plate with brush insert 1 7705.035 7705.035 7705.035 346<br />
Gland plate for metric cable glands 1 7705.235 7705.235 7705.235 346<br />
Fan expansion kit, 230 V 1 7980.100 7980.100 7980.100 127<br />
Spare filter mats 5 3322.700 3322.700 3322.700 149<br />
Wall mounting bracket, 40 mm 4 2503.010 2503.010 2503.010 294<br />
Lock inserts see page 285<br />
Component shelf 2 U, static installation or<br />
fully extendible, 300 mm deep<br />
1 7148.035 7148.035 7148.035 321<br />
Component shelf 2 U, static installation,<br />
250 mm deep<br />
1 7119.250 7119.250 7119.250 323<br />
Fans<br />
230 V AC or 48 V DC,<br />
see page 135.<br />
Socket strips<br />
for mounting in the wall section<br />
or on the 482.6 mm (19″) profile,<br />
see page 328.<br />
Accessories Page 252 Cable shunting ring Page 355 Slide rails Page 384<br />
62 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal EL, 3-part, with punched rails, depth 473<br />
T1<br />
T3 T2<br />
B1<br />
H2<br />
H1<br />
<strong>Networking</strong><br />
T4<br />
B2<br />
Material:<br />
Wall and hinged part:<br />
Sheet steel, 1.5 mm<br />
Viewing window:<br />
Toughened safety glass 3 mm<br />
Colour:<br />
Wall and hinged part:<br />
Powder-coated, RAL 7035<br />
Glazed door: RAL 7035/7015<br />
(slate grey)<br />
Protection category:<br />
IP 55 to EN 60 529/10.91<br />
Supply includes:<br />
Wall section:<br />
with vertical punched rails and C<br />
rail mounted horizontally for<br />
cable clamping, solid cable<br />
gland plate top and bottom,<br />
wall mounting bracket 10 mm.<br />
Hinged part:<br />
with 25 mm pitch pattern of<br />
holes in the front and rear frame,<br />
Two 482.6 mm (19″) mounting<br />
angles mounted on C rails,<br />
infinitely depth-variable.<br />
Designer glazed door:<br />
6 – 15 U with mini comfort<br />
handle for lock inserts,<br />
18 – 21 U with comfort handle<br />
and 2-point locking,<br />
including lock 3524 E.<br />
Available on request:<br />
● Fully modified wall-mounted<br />
distributors<br />
● Special sizes<br />
(D = 373 mm, 573 mm)<br />
● Glazed door with aluminium<br />
frame<br />
● Sheet steel door, solid<br />
Approvals,<br />
see page 403.<br />
Detailed drawing,<br />
available on the Internet.<br />
U Packs of 6 9 12 15 18 21 Page<br />
Width (B1) mm 600 600 600 600 600 600<br />
Height (H1) mm 345 478 612 746 878 1012<br />
Depth (T1) mm 473 473 473 473 473 473<br />
Clearance width (B2) mm 502 502 502 502 502 502<br />
Clearance height (H2) mm 284 417 551 684 817 951<br />
Depth of wall section (T2) mm 135 135 135 135 135 135<br />
Depth of hinged part (T3) mm 316 316 316 316 316 316<br />
Maximum installation depth (T4) mm 420 420 420 420 420 420<br />
Model No. DK 1 7706.135 7709.135 7712.135 7715.135 7718.135 1) 7721.135<br />
Load capacity, hinged part (kg) 30 45 60 75 75 75<br />
Accessories<br />
Gland plate with brush insert 1 7705.035 7705.035 7705.035 7705.035 7705.035 7705.035 346<br />
Gland plate for metric cable glands 1 7705.235 7705.235 7705.235 7705.235 7705.235 7705.235 346<br />
Base/plinth 1 7505.300 7505.300 7505.300 7505.300 7505.300 7505.300 259<br />
Wall mounting bracket, 40 mm 4 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 294<br />
Lock inserts see page 285<br />
Earth rail, horizontal 1 7113.000 7113.000 7113.000 7113.000 7113.000 7113.000 338<br />
Component shelf 2 U, static installation and fully<br />
extendible<br />
1 7148.035 7148.035 7148.035 7148.035 7148.035 7148.035 321<br />
Component shelf 2 U, static installation, 250 mm deep 1 7119.250 7119.250 7119.250 7119.250 7119.250 7119.250 323<br />
Component shelf 1 U, static installation, 140 mm deep 1 7119.140 7119.140 7119.140 7119.140 7119.140 7119.140 322<br />
1)<br />
Delivery times available on request.<br />
Slide rails<br />
to support heavy components<br />
on the 482.6 mm (19″) profile,<br />
see page 384.<br />
Semi-cylinder<br />
for individual locks in the comfort<br />
or mini comfort handle,<br />
see page 287.<br />
Accessories Page 252 Socket strips Page 328 LSA connection system Page 397 Wall mounting Page 294<br />
Rittal IT catalogue/<strong>Networking</strong><br />
63
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal EL, 3-part, with punched rail, depth 373<br />
H2<br />
H1<br />
<strong>Networking</strong><br />
T1<br />
T3 T2<br />
B1<br />
B3<br />
T4<br />
H3<br />
B2<br />
Material:<br />
Wall and hinged part:<br />
1.5 mm sheet steel<br />
Mounting plate:<br />
2.5 mm sheet steel, zinc-plated,<br />
passivated<br />
Viewing window:<br />
Toughened safety glass 3 mm<br />
Colour:<br />
Wall and hinged part:<br />
Powder-coated, RAL 7035<br />
Glazed door: RAL 7035/7015<br />
(slate grey)<br />
Protection category:<br />
IP 55 to EN 60 529/10.91<br />
Supply includes:<br />
Wall section:<br />
with 2 cable gland plates,<br />
1 mounting plate supplied loose,<br />
assembly parts.<br />
Hinged part:<br />
with 2 mounting angles,<br />
482.6 mm (19″), fitted at the<br />
front, assembly parts.<br />
Designer glazed door:<br />
3 – 15 U with mini comfort<br />
handle for lock inserts,<br />
18 – 21 U with comfort handle<br />
and 2-point locking,<br />
including lock 3524 E.<br />
Available on request:<br />
● Special sizes and colours<br />
● Glazed door with aluminium<br />
frame<br />
● Sheet steel door, solid<br />
Approvals,<br />
see page 403.<br />
Detailed drawing,<br />
available on the Internet.<br />
U Packs of 3 6 9 12 15 18 21 Page<br />
Width (B1) mm 600 600 600 600 600 600 600<br />
Height (H1) mm 212 345 478 612 746 878 1012<br />
Depth (T1) mm 373 373 373 373 373 373 373<br />
Clearance width (B2) mm 502 502 502 502 502 502 502<br />
Clearance height (H2) mm 151 284 417 551 684 817 951<br />
Depth of wall section (T2) mm 135 135 135 135 135 135 135<br />
Depth of hinged part (T3) mm 216 216 216 216 216 216 216<br />
Maximum installation depth (T4) mm 320 320 320 320 320 320 320<br />
Width of mounting plate (B3) mm 485 485 485 485 485 485 485<br />
Height of mounting plate (H3) mm 165 299 432 565 699 832 965<br />
Model No. EL 1 2243.605 2246.605 2249.605 2252.605 2255.605 2258.605 1) 2261.605<br />
Load capacity, hinged part (kg) 15 30 45 60 75 75 75<br />
Accessories<br />
Wall mounting bracket 10 mm 4 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 294<br />
Wall mounting bracket 40 mm 4 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 294<br />
Gland plate with brush insert 1 7705.035 7705.035 7705.035 7705.035 7705.035 7705.035 7705.035 346<br />
Gland plate for metric cable glands 1 7705.235 7705.235 7705.235 7705.235 7705.235 7705.235 7705.235 346<br />
Cable glands see page 348<br />
Lock inserts see page 285<br />
Slide rails 10 2240.000 2240.000 2240.000 2240.000 2240.000 2240.000 2240.000 384<br />
C rails 4 2238.000 2238.000 2238.000 2238.000 2238.000 2238.000 2238.000 307<br />
Blanking plates 3 see page 393<br />
1)<br />
Delivery times available on request.<br />
Blanking panels<br />
for filling in empty “U” space,<br />
see page 392.<br />
Gland plates<br />
for PG segments for cable<br />
routing with a high protection<br />
category,<br />
see page 347.<br />
Accessories Page 252 Earthing Page 337 Cable management panel Page 362 Component shelf Page 318<br />
64 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal EL, 3-part, with mounting plate, depth 473<br />
T1<br />
T3 T2<br />
B1<br />
B3<br />
H2<br />
H1<br />
<strong>Networking</strong><br />
T4<br />
H3<br />
B2<br />
Material:<br />
Wall and hinged part:<br />
1.5 mm sheet steel<br />
Mounting plate:<br />
2.5 mm sheet steel, zinc-plated,<br />
passivated<br />
Viewing window:<br />
Toughened safety glass 3 mm<br />
Colour:<br />
Wall and hinged part:<br />
Powder-coated, RAL 7035<br />
Glazed door: RAL 7035/7015<br />
(slate grey)<br />
Protection category:<br />
IP 55 to EN 60 529/10.91<br />
Supply includes:<br />
Wall section:<br />
with 2 cable gland plates,<br />
1 mounting plate supplied loose,<br />
assembly parts.<br />
Hinged part:<br />
with 2 mounting angles,<br />
482.6 mm (19″), fitted,<br />
assembly parts.<br />
Designer glazed door:<br />
3 – 15 U with mini comfort<br />
handle for lock inserts,<br />
18 – 21 U with comfort handle<br />
and 2-point locking,<br />
including lock 3524 E.<br />
Available on request:<br />
● Special sizes and colours<br />
● Glazed door with aluminium<br />
frame<br />
● Sheet steel door, solid<br />
Approvals,<br />
see page 403.<br />
Detailed drawing,<br />
available on the Internet.<br />
U Packs of 3 6 9 12 15 18 21 Page<br />
Width (B1) mm 600 600 600 600 600 600 600<br />
Height (H1) mm 212 345 478 612 746 878 1012<br />
Depth (T1) mm 473 473 473 473 473 473 473<br />
Clearance width (B2) mm 502 502 502 502 502 502 502<br />
Clearance height (H2) mm 151 284 417 551 684 817 951<br />
Depth of wall section (T2) mm 135 135 135 135 135 135 135<br />
Depth of hinged part (T3) mm 316 316 316 316 316 316 316<br />
Maximum installation depth (T4) mm 420 420 420 420 420 420 420<br />
Width of mounting plate (B3) mm 485 485 485 485 485 485 485<br />
Height of mounting plate (H3) mm 165 299 432 565 699 832 965<br />
Model No. EL 1 2253.605 2256.605 2259.605 2262.605 2265.605 2268.605 1) 2271.605<br />
Load capacity, hinged part (kg) 15 30 45 60 75 75 75<br />
Accessories<br />
Wall mounting bracket 10 mm 4 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 2508.010 294<br />
Wall mounting bracket 40 mm 4 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 2503.010 294<br />
Lock inserts see page 285<br />
Gland plate with brush insert 1 7705.035 7705.035 7705.035 7705.035 7705.035 7705.035 7705.035 346<br />
Gland plate for metric cable glands 1 7705.235 7705.235 7705.235 7705.235 7705.235 7705.235 7705.235 346<br />
Base/plinth 1 7505.300 7505.300 7505.300 7505.300 7505.300 7505.300 7505.300<br />
Cable glands see page 348<br />
Slide rails 10 2250.000 2250.000 2250.000 2250.000 2250.000 2250.000 2250.000 384<br />
C rails 4 2239.000 2239.000 2239.000 2239.000 2239.000 2239.000 2239.000 307<br />
Blanking plates 3 see page 393<br />
1)<br />
Delivery times available on request.<br />
Base/plinth<br />
can be fitted with castors,<br />
see page 259.<br />
The 1 U component shelf can<br />
be secured in the centre section<br />
to support non 19″ mountable<br />
components,<br />
see page 322.<br />
Accessories Page 252 Socket strip Page 328 Wall mounting Page 294 Cable clamps Page 352<br />
Rittal IT catalogue/<strong>Networking</strong><br />
65
<strong>Networking</strong><br />
Wall-mounted enclosures, based on Rittal EL, 2-part, with swing frame, depth 369<br />
T1<br />
B1<br />
<strong>Networking</strong><br />
T2 T3<br />
B2<br />
H2<br />
H1<br />
Material:<br />
Enclosure: 1.5 mm sheet steel<br />
Swing frame: Sheet steel<br />
Front door: Extruded aluminium<br />
section, 3 mm acrylic glazing<br />
Supply includes:<br />
Enclosure, front door,<br />
fitted swing frame,<br />
including assembly parts.<br />
Available on request:<br />
● Special sizes and colours<br />
Approvals,<br />
see page 404.<br />
Detailed drawing,<br />
available on the Internet.<br />
Surface finish:<br />
Enclosure and swing frame:<br />
Primed and powder-coated,<br />
RAL 7035<br />
Front door:<br />
Dark brown anodised<br />
Protection category:<br />
IP 55 to EN 60 529/10.91<br />
U Packs of 6 11 14 Page<br />
Width (B1) mm 600 600 600<br />
Height (H1) mm 380 600 760<br />
Depth (T1) mm 369 369 369<br />
Clearance width (B2) mm 537 537 537<br />
Clearance height (H2) mm 317 537 697<br />
Distance from glazed door to swing frame (T2) mm 67 – 97 67 – 97 67 – 97<br />
Maximum installation depth (T3) mm 270 270 270<br />
Model No. EL 1 1919.500 1920.500 1926.500<br />
Accessories<br />
Wall mounting bracket, 10 mm 4 2508.010 2508.010 2508.010 294<br />
Wall mounting bracket, 40 mm 4 2503.010 2503.010 2503.010 294<br />
Gland plates with hole 5 2563.000 2563.000 2563.000 342<br />
Blanking plates 3 see page 393<br />
Standard swing frame with double-bit lock insert may be exchanged for 27 mm lock inserts, type A, see page 285.<br />
Wall mounting bracket<br />
for mounting the enclosure<br />
either 10 mm or 40 mm away<br />
from the wall,<br />
see page 294.<br />
Combination rails<br />
for securing cables to the<br />
T-heads or the C section,<br />
see page 352.<br />
Accessories Page 252 Cage nuts Page 314 Patch panel for copper transmission cables Page 389 Socket strips Page 328<br />
66 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
EMC wall-mounted enclosure, based on Rittal EL, 3-part<br />
120<br />
100<br />
80<br />
dB<br />
60<br />
40<br />
20<br />
1<br />
2<br />
3<br />
4<br />
0<br />
0.01 0.05 0.1 0.5 1 5 10 50 100 500 1000 5000<br />
MHz<br />
MHz = Frequency<br />
dB = RF attenuation<br />
1 E field = Electrical field<br />
[V/m] EMC enclosures<br />
2 E field standard<br />
enclosures<br />
3 H field = Magnetic field<br />
[A/m] EMC enclosures<br />
4 H field standard<br />
enclosures<br />
<strong>Networking</strong><br />
The Rittal EMC concept<br />
Rittal offers excellent standard<br />
sheet steel enclosures, EMCshielded<br />
enclosures and a practical<br />
range of EMC accessories.<br />
Even the standard enclosures<br />
offer good shielding against<br />
electrical fields which is generally<br />
sufficient for many applications.<br />
Depending on the individual<br />
application, anything is possible,<br />
be it closely intermeshed<br />
potential equalisation in a standard<br />
enclosure to prevent conducted<br />
interference, or extra<br />
shielding to protect against<br />
high-frequency electromagnetic<br />
fields.<br />
Rittal EMC enclosures have a<br />
high level of shielding, excellent<br />
attenuation levels and are valuefor-money<br />
products. This is<br />
achieved by zinc-plated metal<br />
surfaces in conjunction with lowresistance<br />
EMC shields.<br />
According to EMC legislation,<br />
CE labelling is only compulsory<br />
for (active) equipment and systems.<br />
Empty enclosures are not subject<br />
to the EMC Directive<br />
because these are passive components<br />
which cannot be furnished<br />
with a declaration of conformity<br />
with regard to EMC<br />
standards.<br />
Material:<br />
Wall unit and centre part:<br />
1.5 mm sheet steel<br />
Mounting plate:<br />
2.5 mm sheet steel<br />
Front door:<br />
Extruded aluminium section,<br />
die-cast aluminium corner<br />
connectors, 4 mm polycarbonate<br />
window,<br />
with EMC mesh.<br />
Surface finish:<br />
Powder-coated,<br />
enclosure RAL 7035,<br />
door frame RAL 7033.<br />
Protection category:<br />
IP 55 to EN 60 529/10.91<br />
Supply includes:<br />
1 wall unit, solid,<br />
2 gland plates, solid,<br />
1 centre part, vertically hinged,<br />
2 mounting angles, 482.6 mm<br />
(19″), fitted,<br />
1 mounting plate, zinc-plated,<br />
1 front door with EMC polycarbonate<br />
window.<br />
Approvals:<br />
● TÜV<br />
● Norske Veritas<br />
● Russian Maritime<br />
Register of Shipping<br />
● Lloyds Register of Shipping<br />
● VDE<br />
● UL – Underwriters Laboratories<br />
Inc.<br />
for USA and Canada<br />
U 6<br />
Width mm 600<br />
Height mm 345<br />
Depth mm 515<br />
Model No. EL 2256.705<br />
Delivery times available on request.<br />
Further information,<br />
available on the Internet.<br />
Rittal IT catalogue/<strong>Networking</strong><br />
67
<strong>Networking</strong><br />
Small fibre-optic distributors<br />
T2<br />
H<br />
<strong>Networking</strong><br />
B2<br />
B1<br />
T1<br />
Material:<br />
Sheet steel, 1.5 mm<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Supply includes:<br />
1 enclosure, two-part, to accommodate<br />
a maximum of 48 or 96<br />
optical fibres,<br />
1 wall section:<br />
with mounting holes for wall<br />
mounting,<br />
11 or 16 shunting rings:<br />
for patching cables/fibre stock,<br />
1 or 2 splicing cassette holders:<br />
To accommodate a maximum of<br />
8 or 16 splicing cassettes,<br />
2 comb strips:<br />
for cable clamping, and brush<br />
inserts to provide protection<br />
against dust,<br />
1 cover:<br />
with suspension device and two<br />
cam locks.<br />
Note:<br />
When the small fibre-optic distributor<br />
is used without a patch<br />
panel, 1 or 2 splicing cassette<br />
holders may be retrofitted (maximum<br />
splicing cassette accommodation<br />
16 or 32).<br />
Available on request:<br />
● Special designs<br />
Property rights:<br />
German patent no. 44 10 795<br />
Detailed drawing,<br />
available on the Internet.<br />
Width (B1) mm Packs of 500 500 Page<br />
Height (H) mm 500 900<br />
Depth (T1) mm 120 120<br />
Width of cable entry (B2) mm 395 395<br />
Depth of cable entry (T2) mm 29 29<br />
Model No. DK 1 7452.035 7453.035<br />
Number of fibres (when using patch panels) 1 – 48 1 – 96<br />
Accessories<br />
Patch panels with 12/24 locations for fibre-optic couplings<br />
Maximum population<br />
2 patch panels<br />
Maximum population<br />
4 patch panels<br />
F-SMA 6.5 mm, 24 locations 2 7456.035 1) 7456.035 1) –<br />
F-SMA 7.5 mm, 24 locations 2 7457.035 1) 7457.035 1) –<br />
ST, 24 locations 2 7458.035 7458.035 –<br />
DIN 47 256, 24 locations 2 7459.035 1) 7459.035 1) –<br />
SC, E-2000, E-2000 duplex, 24/12 locations 2 7460.035 1) 7460.035 1) –<br />
SC duplex, 12 locations 2 7460.135 1) 7460.135 1) –<br />
Splicing cassette holder for retrofitting 1 7450.035 7450.035 394<br />
Lock systems<br />
T handle without lock insert 1 2572.000 2572.000 285<br />
T handle with lock insert no. 3524 E 1 2575.000 2575.000 285<br />
Plastic handle with lock no. Nr. 3524 E 1 2576.000 2576.000 286<br />
Plastic handle 1 2533.000 2533.000 286<br />
Standard double-bit lock insert may be exchanged for 27 mm lock inserts, type A, see page 285.<br />
1)<br />
Delivery times available on request.<br />
Splicing cassette holder<br />
incl. cassette cover,<br />
see page 394.<br />
Blanking cover<br />
for unused cut-outs in patch<br />
panels,<br />
see page 395.<br />
Accessories Page 252 Lock systems Page 281 Nylon loop Page 353<br />
68 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Small fibre-optic distributors, based on Rittal AE<br />
B2<br />
T1<br />
B1<br />
H1<br />
H2<br />
<strong>Networking</strong><br />
Layout of the small fibre-optic<br />
distributor:<br />
Basic enclosure:<br />
With cable shunting rings to<br />
accommodate the fibre stock<br />
and a strain relief system for<br />
incoming and outgoing cables.<br />
Mounting plate:<br />
With accommodation for<br />
4 splicing cassettes and<br />
4 patch panels.<br />
Patch panels:<br />
There are 4 patch panels available<br />
with varying cut-outs.<br />
Other special versions available<br />
on request.<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Protection category:<br />
IP 55 (to EN 60 529/10.91)<br />
when using suitable cable gland<br />
plates.<br />
Supply includes:<br />
1 enclosure of sheet steel with<br />
2 gland plates of sheet steel,<br />
sides,<br />
1 gland plate, bottom<br />
7 cable shunting rings<br />
70 x 44 mm,<br />
2 strain relief clips,<br />
1 cable clamp rail, double,<br />
1 door of sheet steel,<br />
with double-bit locks, with<br />
2 hinges on the right,<br />
1 mounting plate of sheet steel<br />
with 6 cable shunting rings<br />
70 x 44 mm,<br />
4 recesses for patch panels,<br />
1 splicing cassette holder.<br />
Detailed drawing,<br />
available on the Internet.<br />
Width (B1) mm Packs of 400 Page<br />
Height (H1) mm 500<br />
Depth (T1) mm 155<br />
Mounting plate width (B2) mm 355<br />
Mounting plate height (H2) mm 455<br />
Model No. DK 1 7454.000<br />
Number of fibres (when using patch panels) 1 – 48<br />
Accessories<br />
Patch panel, maximum population with 4 patch panels<br />
Locations<br />
Patch panel for ST couplings 12 2 7462.000<br />
Patch panel for SC, E-2000, E-2000 duplex couplings 12/6 2 7463.100<br />
Patch panel for SC duplex couplings 6 2 7463.200<br />
Cable gland with 2 half-shells, cable diameter from 8 – 36 mm, for mounting at the bottom,<br />
reduced protection category<br />
1 2400.000 349<br />
Plastic cable gland plates, PG size 13.5, for side mounting 5 1581.000 342<br />
Plastic cable gland plates, PG size 13.5 /16/21, for side mounting 5 1582.000 342<br />
Wall mounting bracket, 40 mm 4 2503.010 294<br />
Wall mounting bracket, 10 mm 4 2508.010 294<br />
Lock systems<br />
Plastic handle 1 2533.000 286<br />
Plastic handle with lock cylinder insert 1 2576.000 286<br />
Lock cylinder insert no. 3524 E 1 2571.000 286<br />
Standard double-bit lock insert may be exchanged for 27 mm lock inserts, type A, see page 285.<br />
Connector gland<br />
for pre-assembled cables,<br />
see page 349.<br />
Plastic handle<br />
with a lock cylinder,<br />
see page 286.<br />
Accessories Page 252 Plastic cable gland plates Page 342 Wall mounting Page 294<br />
Rittal IT catalogue/<strong>Networking</strong><br />
69
<strong>Networking</strong><br />
Fibre-optic marshalling enclosure<br />
T<br />
H<br />
<strong>Networking</strong><br />
800<br />
B<br />
60<br />
Patch panels are easily fastened<br />
within the apeture. A door<br />
is provided to cover and lock the<br />
splicing cassette accommodation.<br />
A second door covers and<br />
locks the secondary chamber/<br />
splicing cassette accommodation.<br />
Both doors are provided<br />
with different locks.<br />
Material:<br />
Sheet steel, 1.0 mm<br />
Colour:<br />
RAL 7035<br />
Surface finish:<br />
Enclosure: Powder-coated,<br />
RAL 7035<br />
Supply includes:<br />
1 enclosure to accommodate a<br />
maximum of 24 optical fibres,<br />
wall section with mounting holes<br />
for wall mounting,<br />
2 doors with different locks,<br />
for separate access,<br />
4 shunting rings, 70 x 44 mm,<br />
2 splicing cassette holders<br />
each for 2 splicing cassettes,<br />
4 rubber seals for cable entry,<br />
4 comb strips for cable clamping.<br />
Note:<br />
If the marshalling enclosure is<br />
used without patch panels,<br />
4 splicing cassettes,<br />
2 per side, may be integrated.<br />
Property rights:<br />
German patent<br />
No. 195 47 135<br />
European patent no. 0 867 058<br />
with validity for NL<br />
European patent no. 0 867 059<br />
with validity for DE, FR, GB, IT<br />
Available on request:<br />
● Other variants<br />
Detailed drawing,<br />
available on the Internet.<br />
Width (B) mm Packs of 400 Page<br />
Height (H) mm 250<br />
Depth (T) mm 120<br />
Model No. DK 1 7247.000<br />
Number of fibres (when using patch panels) 1 – 24<br />
Accessories<br />
Patch panel for 24 ST couplings 1 7247.010<br />
Patch panel for 24 SC, E-2000 couplings 1) 1 7247.020<br />
Patch panel for 12 SC duplex couplings 1 7247.030<br />
1) 12 E-2000 duplex couplings may be accommodated.<br />
Accessories Page 252<br />
70 Rittal IT catalogue/<strong>Networking</strong>
<strong>Networking</strong><br />
Small fibre-optic distributor, polycarbonate<br />
170<br />
H<br />
T<br />
145<br />
169.5<br />
244<br />
<strong>Networking</strong><br />
B<br />
Configuration<br />
Small fibre-optic distributor:<br />
Mounting plate:<br />
With accommodation for one or<br />
two splicing cassettes, the width<br />
of the cassettes may vary from<br />
92 to 120 mm.<br />
Dividing plate:<br />
Covers the splicing cassettes<br />
and separates them from the<br />
patch cables. Aperture for patch<br />
panels and a cable clamp are<br />
also integrated.<br />
Patch panels:<br />
Patch panels for<br />
F-SMA, E-2000-ST couplings,<br />
E-2000 duplex and SC and<br />
SC duplex couplings are<br />
available.<br />
Other special variants available<br />
on request.<br />
Cable entry:<br />
For cable entry, there are prepunchings<br />
for PG cable glands<br />
integrated into the small fibreoptic<br />
distributor.<br />
The cable glands (12 x PG 7<br />
and 1 x PG 16) are included with<br />
the supply. Pre-assembled connectors<br />
will also fit through the<br />
knockout apertures (for diameters,<br />
see below). Depending on<br />
diameter, the cable can either<br />
be held in the knockouts by a<br />
2-part cable entry gland or cable<br />
entry sleeves. The two-part<br />
cable entry and the grommets<br />
are not included with the supply,<br />
due to the different cable<br />
diameters.<br />
Diameter of the pre-punched<br />
knockouts:<br />
12 x 12.5 mm<br />
2 x 22.5 mm<br />
Material:<br />
Enclosure and cover:<br />
Fibreglass-reinforced polycarbonate<br />
Cover screws: Polyamide<br />
Colour:<br />
RAL 7035<br />
Protection category:<br />
IP 66 to EN 60 529/10.91.<br />
Supply includes:<br />
1 enclosure and lid of fibreglassreinforced<br />
polycarbonate to<br />
accommodate splicing cassettes<br />
and patch panels,<br />
1 enclosure lid with 2 hinges,<br />
knockouts for PG glands are<br />
integrated into the enclosure,<br />
12 x cable gland PG 7,<br />
1 x cable gland PG 16,<br />
1 mounting plate with variable<br />
accommodation of 2 splicing<br />
cassettes and integral anti-twist<br />
guard,<br />
1 dividing plate to cover the<br />
splicing cassette, accommodation<br />
for 2 patch panels and<br />
comb strip for cable clamping,<br />
2 lid screws of polyamide with<br />
option of preparing for a lead<br />
seal, polyamide insulating bungs<br />
for wall mounting screws.<br />
All-round foamed-in PU seal.<br />
Detailed drawing,<br />
available on the Internet.<br />
Width (B) mm Packs of 180 Page<br />
Height (H) mm 254<br />
Depth (T) mm 90<br />
Model No. DK 1 7451.000<br />
Number of fibres (when using patch panels) 1 – 24<br />
Accessories<br />
Locations<br />
per patch panel<br />
Locations<br />
per enclosure<br />
Patch panel for 7.5 mm F-SMA couplings 12 24 2 7461.000<br />
Patch panel for ST couplings 12 24 2 7462.000<br />
Patch panel for SC, E-2000,<br />
E-2000 duplex couplings<br />
12/6 24/12 2 7463.100<br />
Patch panel for SC duplex couplings 6 12 2 7463.200<br />
Wall mounting brackets 40 9583.000<br />
Wall mounting brackets<br />
Attach securely to the enclosure<br />
simply by clipping in.<br />
Accessories Page 252<br />
Rittal IT catalogue/<strong>Networking</strong><br />
71
As different<br />
as our customers<br />
Rittal offers a range of server racks which are sure to<br />
impress, thanks to their versatility, innovative technology and<br />
stylish performance.<br />
We have the perfect rack for your application – i.e. data<br />
centres, server rooms or as stand-alone solutions.<br />
Functionality and assembly-friendliness are basic requirements.<br />
Depending on the various conditions and objectives<br />
Server racks 74<br />
System comparison of racks ............................................................74<br />
Installation example of the TE 7000 server rack...............................76<br />
Installation example of the TS 8 server rack.....................................78<br />
Parts list for the configuration example TE 7000 ..............................80<br />
Parts list for the configuration example TS 8 ....................................81<br />
Based on Rittal TE 7000/TS 8 in RAL 9005.......................................82<br />
Based on Rittal TE 7000, 1000 mm deep .........................................84<br />
Based on Rittal TS 8, pre-configured ...............................................85<br />
Based on Rittal flexRack(i), 1000 and 1200 mm deep,<br />
pre-configured ..................................................................................87<br />
Based on Rittal TS 8, High Performance Cooling systems HPC ......88<br />
Smart Package, based on Rittal TS 8, pre-configured .....................89<br />
Server racks<br />
of our clients modern server racks must also meet exacting<br />
standards in terms of power supply, climate control and<br />
access protection for the system, depending on the various<br />
conditions and objectives of our clients.<br />
Every application is different. Rittal is designed for this.<br />
TE 7000 server racks<br />
The functional and economic server<br />
rack – for applications where only<br />
482.6 mm (19″) equipment is<br />
installed, and optimum accessibility<br />
is important.<br />
TS 8 server racks<br />
Whether 482.6 mm (19″), metric or<br />
across the entire width, as a server<br />
rack the TS 8 offers ingenious installation<br />
diversity with innovative technology.<br />
This is complemented by a<br />
high load capacity of up to 1000 kg,<br />
an optimum airflow with 78 % free ventilation<br />
area, plus optimum opportunities<br />
for combining with liquid cooling<br />
and other climate control concepts.<br />
TS 8 – A genuine all-rounder with<br />
exceptional strengths in demanding<br />
IT environments.<br />
Smart Package<br />
For common practical requirements –<br />
pre-configured server racks based on<br />
TS 8. Ready to plug & play.<br />
Depending on your chosen design, climate<br />
control components, multi-phase<br />
power supply including UPS, CMC-TC<br />
monitoring system and various accessory<br />
components are already integrated.<br />
Rittal IT catalogue/Server racks<br />
73
Server racks<br />
System comparison of racks<br />
Rittal TE 7000<br />
Rittal server rack solutions are as versatile as your requirements!<br />
Three system platforms with various strengths<br />
Server racks<br />
in terms of security, interior installation, climate control<br />
and design provide the basis for server racks with<br />
carefully selected configurations to meet your requirements<br />
precisely.<br />
Rittal system comparison TE 7000 TS 8 FR(i)<br />
One platform for all requirements<br />
in the IT market<br />
Load capacity<br />
up to 700 kg <br />
up to 1000 kg <br />
Baying<br />
Side to side <br />
In all levels<br />
<br />
Dismantling <br />
Climate control<br />
Fans <br />
Cooling unit<br />
<br />
Air/water heat exchanger<br />
<br />
CPU liquid cooling <br />
Cabling<br />
Cable space <br />
Cable management <br />
Lock system<br />
2-point <br />
4-point<br />
<br />
Security<br />
Access control <br />
Thermal management <br />
Interior installation<br />
Depth-variable <br />
Partial installation<br />
<br />
2-level principle <br />
Aesthetics <br />
Standards<br />
IEC 60 297-1-2 <br />
Note:<br />
The more the greater the compatibility.<br />
TE 7000 – the Top Efficiency server rack<br />
With two depth-variable 482.6 mm (19″) frames (without<br />
enclosure frame), the practical rack for the server room.<br />
● Optimum accessibility.<br />
● Fully vented front and rear door,<br />
> 63 % free ventilation area.<br />
● 2-point locking rod,<br />
optionally with Ergoform-S handle system.<br />
Server racks based on Rittal TE 7000, see page 84.<br />
74 Rittal IT catalogue/Server racks
Server racks<br />
System comparison of racks<br />
Rittal TS 8<br />
Rittal flexRack(i)<br />
Server racks<br />
TS 8 – The server rack with no limitations<br />
Rittal TS 8 server racks offer the ideal conditions to combine<br />
all the relevant technologies into complete IT infrastructure<br />
solution.<br />
Each rack makes an important contribution to the physical<br />
security of your IT infrastructure and forms the interface to<br />
pioneering climate control concepts.<br />
● Ventilation via perforated front and rear ventilated door with<br />
open area of 78 %.<br />
● Lock system with comfort handle and 4-point locking.<br />
● The ingenious symmetry concept of the frame offers baying<br />
on all sides.<br />
● Frame section with unlimited mounting diversity.<br />
● High load capacity up to 1000 kg.<br />
Server racks based on Rittal TS 8, see page 85.<br />
flexRack(i) – Smart design, exceptional technology<br />
The server rack with a highly individual touch. The curved<br />
designer door unites functionality with aesthetics, while the<br />
aluminium system channel in the frame sections accommodates<br />
redundant socket strips, cabling or even rising mains<br />
from liquid cooling systems with no loss of space.<br />
● Aluminium vertical sections with multi-functional system<br />
channel.<br />
● Screw-fastened enclosure system, may be dismantled.<br />
● Vented front and rear door<br />
with open surface area of 64 % in the perforated plate.<br />
● 2-point locking.<br />
● Stabilisers for optimum operational safety.<br />
Server racks based on Rittal flexRack(i), see page 87.<br />
Rittal IT catalogue/Server racks<br />
75
TE 7000 server rack<br />
Top Efficiency – The TE 7000 as server rack!<br />
In depths of up to 1000 mm, the TE offers a rational, costeffective<br />
solution to your server room and data centre requirements<br />
with a stable, depth-variable 482.6 mm (19″) frame.<br />
Optimum installation access with the doors and walls<br />
Server racks<br />
removed.<br />
Rittal offers everything needed to configure a plug & play<br />
rack: Compatible modules for power supply, cooling,<br />
security, monitoring, and a comprehensive range of system<br />
accessories.<br />
Note:<br />
TE 7000 server racks, see page 84.<br />
Parts list with model numbers for this example,<br />
see page 80.<br />
6<br />
13<br />
1<br />
11<br />
14<br />
7<br />
2<br />
16<br />
8<br />
15<br />
3<br />
9<br />
12<br />
18 17<br />
4<br />
5<br />
21<br />
20<br />
19<br />
10<br />
22<br />
Example: System accessories for perfect configuration of a TE 7000 server rack<br />
Use these examples to help you.<br />
6 Plug-in module, PSM, earthing-pin<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Blanking panel, 482.6 mm (19″), 2 U<br />
Cable management panel<br />
Cable routing bar, cranked, 4 U<br />
Cable routing bar, 1 U<br />
Monitor/keyboard unit, 1 U<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
Plug-in module, PSM, earthing-pin, red<br />
PSM busbar, 2000 mm<br />
Plug-in module, PSM, IEC 320<br />
Plug-in modules, PSM, IEC 320, red<br />
Cable routing bar, 4 U<br />
KVM switch SSC view 8<br />
13 Component shelf, heavy-duty<br />
14 Mounting kit, depth-variable,<br />
for 482.6 mm (19″) component shelves<br />
15 Socket strip, 7-way<br />
16 Distributor clip<br />
17 UPS, single-phase<br />
18 Slide rail, depth-variable, 1 U<br />
19 Base/plinth trim, side<br />
20 Connection cable, single-phase<br />
21 Connection cable, three-phase<br />
22 Base/plinth components, front and rear<br />
Rittal IT catalogue/Server racks<br />
77
TS 8 server rack<br />
With TS 8 your requirements are precisely met.<br />
The decisive TS 8 feature is its symmetrical enclosure frame.<br />
Each vertical section has 4 rows of mounting holes for<br />
unlimited installation opportunities. The section is also the<br />
key for baying on all sides. A high level of access protection<br />
Server racks<br />
is provided by the comfort handle (with security lock) and<br />
4-point locking. Outstanding stability (load capacity up to<br />
1000 kg). The doors have 78 % free ventilation area plus<br />
innovative Rittal climate control concepts offer operational<br />
reliability through cooling.<br />
Note:<br />
TS 8 server racks, see page 85.<br />
Parts list with model numbers for this example,<br />
see page 81.<br />
6<br />
13<br />
14<br />
1<br />
7<br />
12<br />
15<br />
2<br />
8<br />
3<br />
9<br />
16<br />
21<br />
4 5<br />
10<br />
17<br />
18<br />
19<br />
11<br />
20<br />
Example: System accessories for perfect configuration of a TS 8 server rack<br />
Rittal system accessories are available in<br />
many different variants, tailored to the<br />
intended application. 482.6 mm (19″) partial<br />
configuration and the use of component<br />
shelves across the entire enclosure<br />
width are likewise easily achieved.<br />
Use these examples to help you.<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Cable routing bar, 1 U<br />
Cable routing bar, cranked, 4 U<br />
Monitor/keyboard unit, 1 U<br />
Plug-in module, PSM, IEC 320<br />
Plug-in module, PSM, earthing-pin, red<br />
1<br />
2<br />
Blanking panel, 482.6 mm (19″), 2 U<br />
Cable management panel<br />
8<br />
9<br />
10<br />
11<br />
12<br />
PSM busbar, 2000 mm<br />
Plug-in module, PSM, earthing-pin<br />
KVM switch SSC view 8<br />
Plug-in module, IEC 320, red<br />
Cable bar, 1 U<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
Mounting kit, depth-variable,<br />
for 482.6 mm (19″) component shelves<br />
Component shelf, heavy duty<br />
Side panels, plug-type<br />
Slide rail, depth-variable, 1 U<br />
Connection cable, three-phase<br />
Connection cable, single-phase<br />
Base/plinth trim, side<br />
Base/plinth components, front and rear,<br />
vented<br />
UPS, single-phase<br />
Rittal IT catalogue/Server racks<br />
79
Server racks<br />
Parts list for the configuration example TE 7000<br />
Server racks<br />
No. Name Packs of Model No. Page<br />
TE 7000 Server rack<br />
W = 800 mm, H = 2000 mm, D = 1000 mm<br />
1 DK 7000.892 84<br />
System accessories<br />
1 Blanking panel, 19″, 2 U 2 DK 7152.035 392<br />
2 Cable management panel 1 DK 7257.035 361<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
Cable routing bar, cranked, 4 U 4 DK 7111.220 360<br />
Cable routing bar, 1 U 10 DK 7111.212 360<br />
Monitor/keyboard unit, 1 U 1 DK 9055.100 190<br />
Plug-in module, PSM, earthing pin 1 DK 7856.100 100<br />
Plug-in module, PSM, earthing-pin, red 1 DK 7856.240 100<br />
PSM busbar, 2000 mm 1 DK 7856.020 99<br />
Plug-in module, PSM, IEC320 1 DK 7856.080 100<br />
Plug-in module, PSM, IEC320, red 1 DK 7856.082 100<br />
Cable routing bar, 4 U 4 DK 7111.222 360<br />
KVM switch SSC view 8 1 DK 7552.000 191<br />
Component shelf, heavy duty 1 DK 7063.897 321<br />
Mounting kit, depth-variable, for 482.6 mm (19″) component shelves 1 set DK 7063.890 324<br />
Socket strip, 7-way 1 DK 7240.210 328<br />
Distributor clip 4 DK 7111.252 360<br />
UPS, single-phase 1 DK 7857.430 433<br />
Slide rail, depth-variable, 1 U 2 DK 7063.883 384<br />
Base/plinth trims, side 1 set TS 8601.015 255<br />
Connection cable, single-phase 1 DK 7856.026 102<br />
21 Connection cable, 3-phase 1 DK 7856.025 102<br />
22 Base/plinth components, front and rear 1 set TS 8601.085 255<br />
Optional accessories<br />
A Power: Power System Module PSM Plus 103<br />
B Security: CMC-TC monitoring system 158<br />
C Monitoring: KVM switches 191<br />
D Side panels 265<br />
E 19″ installation system 364<br />
F Power strips 328<br />
A<br />
Power System Module<br />
PSM Plus<br />
B<br />
Monitoring system CMC-TC<br />
C KVM switches, SSC premium<br />
D<br />
Side panels<br />
E<br />
19″ installation system<br />
F<br />
Power strips<br />
80 Rittal IT catalogue/Server racks
Server racks<br />
Parts list for the configuration example TS 8<br />
No. Name Packs of Model No. Page<br />
TS 8 server rack<br />
W = 600 mm, H = 2000 mm, D = 1000 mm<br />
1 DK 7831.438 85<br />
System accessories<br />
1 Blanking panel, 19″, 2 U 2 DK 7152.035 392<br />
2 Cable management panel 1 DK 7257.035 361<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
Cable routing bar, 1 U 10 DK 7111.212 360<br />
Cable routing bar, cranked, 4 U 4 DK 7111.220 360<br />
Monitor/keyboard unit, 1 U 1 DK 9055.100 190<br />
Plug-in module, PSM, IEC320 1 DK 7856.080 100<br />
Plug-in module, PSM, earthing-pin, red 1 DK 7856.240 100<br />
PSM busbar, 2000 mm 1 DK 7856.020 99<br />
Plug-in module, PSM, earthing pin 1 DK 7856.100 100<br />
KVM switch SSC view 8 1 DK 7552.000 191<br />
Plug-in module, IEC320, red 1 DK 7856.082 100<br />
Cable routing bar, 1 U 10 DK 7111.210 360<br />
Mounting kit, depth-variable, for 482.6 mm (19″) component shelves 1 set DK 7063.890 324<br />
Component shelf, heavy duty 1 DK 7063.897 321<br />
Side panels, plug-type 2 DK 7824.200 266<br />
Slide rail, depth-variable, 1 U 2 DK 7063.883 384<br />
Connection cable, 3-phase 1 DK 7856.025 102<br />
Connection cable, single-phase 1 DK 7856.026 102<br />
Base/plinth trims, side 1 set TS 8601.015 255<br />
Base/plinth components, front and rear, vented 1 set TS 8601.065 255<br />
21 UPS, single-phase 1 DK 7857.430 433<br />
Optional accessories<br />
A Power: Power Modular Concept 200 104<br />
B Power: Power Distribution Rack PDR/Power Distribution Module PDM 97<br />
C Cooling: Liquid cooling package 129<br />
D Security: CMC-TC monitoring system 158<br />
E Monitoring: KVM switches 191<br />
F Base/plinth 254<br />
Server racks<br />
A<br />
Power Modular Concept<br />
PMC 200<br />
B<br />
Power Distribution Module<br />
PDM<br />
C<br />
Liquid cooling package<br />
D<br />
Monitoring system CMC-TC<br />
E<br />
KVM switch, SSC premium<br />
F<br />
Stabiliser, pull-out<br />
Rittal IT catalogue/Server racks<br />
81
Server racks<br />
RAL 9005<br />
82
Server racks<br />
RAL 9005<br />
The colour black conveys aesthetics and style, understatement and<br />
perfection for server racks in data centres and office environments.<br />
An extensive range of accessories is available for a consistent,<br />
integrated design. Numerous server rack variants on the platforms of<br />
TS 8 and TE 7000 plus a wide range of accessory components are<br />
available off-the-shelf immediately.<br />
Server racks<br />
TS 8 server rack,<br />
see page 85.<br />
TE 7000 server rack,<br />
see page 84.<br />
Everything under control in a<br />
single U. With the Rittal monitor/<br />
keyboard unit in an attractive,<br />
ergonomic design. Available<br />
in various country versions.<br />
Modular base/plinth diversity –<br />
in a variety of sizes and designs.<br />
Plug & play side panel.<br />
With two options: Lockable,<br />
with optional additional internal<br />
latching.<br />
Component shelf for attaching<br />
to the 482.6 mm (19″) frame or<br />
to L-shaped mounting angles –<br />
with an area load of 50 kg and<br />
100 kg.<br />
For TS 8 enclosure series with<br />
comfort handle, an opening<br />
angle of 180° may be achieved<br />
with a sheet steel door.<br />
The comfort handle. The fold-up<br />
system eliminates the need for a<br />
swivel range.<br />
Customised enclosure population<br />
or extension cover.<br />
Slimline, compact long-stroke<br />
keyboard with a high-quality<br />
trackball. Available in various<br />
country layouts.<br />
Rittal IT catalogue/Server racks<br />
83
Server racks<br />
Based on Rittal TE 7000, 1000 mm deep<br />
T1<br />
B<br />
H<br />
HE<br />
19˝<br />
T2<br />
Server racks<br />
HE = U<br />
Benefits:<br />
● No frame structure,<br />
optimum accessibility<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Mounting frame:<br />
Dipcoat-primed<br />
Enclosure panels:<br />
Powder-coated, RAL 7035/9005<br />
Supply includes:<br />
Self-supporting 482.6 mm (19″)<br />
frame structure,<br />
vented sheet steel door front<br />
and rear, two-point locking rod,<br />
recessed handle (front) and<br />
security lock 3524 E, roof plate<br />
with brush strip for cable entry<br />
and concealed cut-out for fan<br />
integration, levelling feet.<br />
Detailed drawing,<br />
available on the Internet.<br />
U 42 42 42 42<br />
Width (B) mm 1) 600 600 800 800<br />
Height (H) mm 1) 2000 2000 2000 2000<br />
Depth (T1) mm 1) 1000 1000 1000 1000<br />
Distance between 482.6 mm (19″) levels in its delivered state (T2) mm 745 745 745 745<br />
Model No. TE<br />
RAL 7035 7000.882 – 7000.892 –<br />
as bayed enclosure without side panels, including baying kit RAL 9005 – 7000.885 – 7000.895<br />
Doors<br />
Sheet steel door front and rear, fully vented,<br />
open surface area 67 % perforated<br />
<br />
Roof<br />
Roof plate including brush strip for cable entry and<br />
with an optional fan<br />
<br />
Floor<br />
Base frame with maximum cut-out for cable entry or passive ventilation,<br />
can be fitted with optional blanking panels<br />
<br />
Interior installation<br />
482.6 mm (19″) mounting frames front and rear <br />
Accessories<br />
Side panels, pluggable, including security lock 3524 E 7000.653 7000.663 7000.653 7000.663<br />
Ergoform-S handle for semi-cylinder, in exchange for the existing lock 2435.000 2452.000 2) 2435.000 2452.000 2)<br />
Fan unit, with 2 fans and thermostat, prewired ready for connection 7000.670 7000.671 3) 7000.670 7000.671 3)<br />
Transport castors, 4 castors including assembly parts 7000.672 7000.672 7000.672 7000.672<br />
C rail, for cable clamping in the enclosure width<br />
via cable clamps, on the 482.6 mm (19″) mounting frame at the rear<br />
7828.060 7828.060 7828.060 7828.060<br />
Cable clamp rail, depth variable 500 – 895 mm,<br />
for cable attachment in the enclosure depth using cable ties<br />
7858.162 7858.162 7858.162 7858.162<br />
Cable clamp rail for cable attachment in the enclosure width<br />
via cable ties, on the 482.6 mm (19″) mounting frame at the rear<br />
7828.062 7828.062 7828.062 7828.062<br />
Earthing kit for TE 7000.675 7000.675 7000.675 7000.675<br />
TE socket strip, 8-way for earthing-pin plugs 7000.630 7000.630 7000.630 7000.630<br />
Included with the supply. 1) All sizes are nominal dimensions. For absolute dimensions, refer to detailed drawings on the Internet.<br />
2) Matt nickel-plated 3) Delivery times on request.<br />
Cable routing Page 341 Power management Page 328 CMC-TC system monitoring Page 158<br />
84 Rittal IT catalogue/Server racks
Server racks<br />
Based on Rittal TS 8, pre-configured<br />
T1<br />
1<br />
B1<br />
H1<br />
Design features<br />
● Robust frame structure<br />
● Front and rear door fully<br />
vented; vented surface area<br />
78 % perforated<br />
● 4-point locking,<br />
2-point locking with multiple<br />
door versions and<br />
H = 1200 mm<br />
● Door hinge may be swapped<br />
to opposite side<br />
● Cable entry via the roof and<br />
base<br />
● Bayable at all levels<br />
● Load capacity up to 1000 kg<br />
Server racks<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure frame:<br />
Dipcoat-primed<br />
Enclosure panels:<br />
Dipcoat-primed, powder-coated<br />
in RAL 7035 or RAL 9005<br />
Mounting angles and punched<br />
sections with mounting flanges:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
Enclosure frame TS 8 with<br />
sheet steel doors front and rear,<br />
vented, with 130° hinges,<br />
L-shaped, depth-variable fitted<br />
mounting angles and/or<br />
482.6 mm (19″) mounting frame,<br />
levelling feet, comfort handle<br />
with security lock and 4-point<br />
lock.<br />
Detailed drawing,<br />
available on the Internet.<br />
1 Optimised air flow<br />
Number of front and rear doors 1 1 1 1 1 1 1 1<br />
U 24 24 42 42 42 47 47 47<br />
Width (B1) mm 2) 600 600 600 600 600 600 600 600<br />
Height (H1) mm 2) 1200 1200 2000 2000 2000 2200 2200 2200<br />
Depth (T1) mm 2) 900 1000 900 1000 1200 900 1000 1200<br />
Model No. DK as bayed enclosure<br />
RAL 7035 7831.431 7831.433 3) 7831.436 7831.438 7831.481 7831.440 7831.442 7831.483<br />
without side panels, without baying kit RAL 9005 7831.432 3) 7831.434 3) 7831.437 7831.439 7831.482 7831.441 7831.443 7831.484 3)<br />
Model No. DK with side panels,<br />
RAL 7035 – – – – 7831.491 – – 7831.493<br />
plug-type<br />
RAL 9005 – – – – 7831.492 – – 7831.494 3)<br />
Doors<br />
Sheet steel doors, vented, front and rear 1) <br />
Roof<br />
Roof plate for cable entry, two-piece <br />
Floor<br />
Levelling feet <br />
Open base, without base frame <br />
Interior installation<br />
482.6 mm (19″) levels, front and rear <br />
L-shaped mounting angles <br />
Mounting angles attached to depth stays <br />
482.6 mm (19″) mounting frames, front and rear – – – – – – – –<br />
Panel earthing, fitted <br />
Individual compartments, shielded/separate cable rout. p. comp. –/– –/– –/– –/– –/– –/– –/– –/–<br />
Accessories<br />
Plug-in side panels<br />
with T lock, IP 20<br />
RAL 7035 7824.129 7824.120 7824.209 7824.200 (7831.491<br />
only)<br />
RAL 9005 7816.129 7816.120 7816.209 7816.200 (7831.492<br />
only)<br />
7824.229 7824.220 (7831.493<br />
only)<br />
7816.229 7816.220 (7831.494<br />
only)<br />
Security lock for side panels 7824.500 7824.500 7824.500 7824.500 7824.500 7824.500 7824.500 7824.500<br />
Base mounting bracket 8800.210 8800.210 8800.210 8800.210 8800.210 8800.210 8800.210 8800.210<br />
Depth-variable slide rail, 1 U 7063.883 7063.883 7063.883 7063.883 7063.883 7063.883 7063.883 7063.883<br />
Stabiliser, pull-out 7825.200 7825.250 7825.200 7825.250 7825.260 7825.200 7825.250 7825.260<br />
Included with the supply. 1) Vented surface area 78 % perforated. 2) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed<br />
drawing on the Internet.<br />
3)<br />
Delivery times on request.<br />
Accessories Page 252 Liquid cooling Page 129 Baying system Page 270<br />
Rittal IT catalogue/Server racks<br />
85
Server racks<br />
Based on Rittal TS 8, pre-configured<br />
Server racks<br />
T1<br />
1<br />
B1<br />
H1<br />
Design features<br />
● Robust frame structure<br />
● Front and rear door fully<br />
vented; vented surface area<br />
78 % perforated<br />
● 4-point locking,<br />
2-point locking with multiple<br />
door versions<br />
● Door hinge may be swapped<br />
to opposite side<br />
● Cable entry via the roof and<br />
base<br />
● Bayable at all levels<br />
● Load capacity up to 1000 kg<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Enclosure frame:<br />
Dipcoat-primed<br />
Enclosure panels:<br />
Dipcoat-primed, powder-coated<br />
in RAL 7035 or RAL 9005<br />
Mounting angles and punched<br />
sections with mounting flanges:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
Enclosure frame TS 8 with sheet<br />
steel doors front and rear,<br />
vented, with 130° hinges,<br />
L-shaped, depth-variable fitted<br />
mounting angles or 482.6 mm<br />
(19″) mounting frame, levelling<br />
feet, comfort handle with security<br />
lock and 4-point lock.<br />
Detailed drawing,<br />
available on the Internet.<br />
1 Optimised air flow<br />
Number of front and rear doors 1 1 1 2 4<br />
U 42 42 47 2 x 21 4 x 10<br />
Width (B1) mm 2) 800 800 800 600 600<br />
Height (H1) mm 2) 2000 2000 2200 2200 2200<br />
Depth (T1) mm 2) 1000 1200 1200 900 900<br />
Model No. DK as bayed enclosure<br />
RAL 7035 7831.446 7831.485 7831.487 3) 7831.450 7831.460<br />
without side panels, without baying kit<br />
RAL 9005 – 7831.486 3) 7831.488 3) 7831.451 3) 7831.461 3)<br />
Model No. DK with side panels,<br />
RAL 7035 – 7831.495 3) 7831.497 3) – –<br />
plug-type<br />
RAL 9005 – 7831.496 3) 7831.498 3) – –<br />
Doors<br />
Sheet steel doors, vented, front and rear 1) <br />
Roof<br />
Roof plate for cable entry, two-piece – –<br />
Roof plate with cable entry openings in the corners – – – <br />
Floor<br />
Levelling feet – –<br />
Open base, without base frame <br />
Interior installation<br />
482.6 mm (19″) levels, front and rear – –<br />
L-shaped mounting angles – – – – –<br />
Mounting angles attached to depth stays – – – <br />
482.6 mm (19″) mounting frames, front and rear – –<br />
Panel earthing, fitted <br />
Individual compartments, shielded/separate cable routing per comp. –/– –/– –/– / /<br />
Accessories<br />
Plug-in side panels<br />
RAL 7035 7824.200 (7831.495 only) (7831.497 only) 7824.229 7824.229<br />
with T lock, IP 20<br />
RAL 9005 – (7831.496 only) (7831.498 only) 7816.229 7816.229<br />
Security lock for side panels 7824.500 7824.500 7824.500 7824.500 7824.500<br />
Base mounting bracket 8800.210 8100.235 8100.235 8800.210 8800.210<br />
Depth-variable slide rail, 1 U 7063.883 7063.883 7063.883 7063.883 7063.883<br />
Stabiliser, pull-out 7825.250 7825.260 7825.260 7825.200 7825.200<br />
Included with the supply. 1) Vented surface area 78 % perforated. 2) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed<br />
drawing on the Internet. 3) Delivery times available on request.<br />
Accessories Page 252 Liquid Cooling Page 129<br />
86 Rittal IT catalogue/Server racks
Server racks<br />
Based on Rittal flexRack(i), 1000 and 1200 mm deep, pre-configured<br />
T1<br />
B1<br />
T2<br />
Server racks<br />
H1<br />
T3<br />
Design features<br />
● Enclosure system may be dismantled<br />
because the vertical<br />
sections are screw-fastened<br />
to the roof and base frame<br />
● Aluminium vertical section<br />
with multi-functional system<br />
channel<br />
● Vented front and rear door<br />
with vented surface area 67 %<br />
perforated<br />
● 2-point locking<br />
● Cable entry via the roof and<br />
base<br />
● Pull-out stabiliser<br />
● Bayable<br />
● Load capacity up to 1000 kg<br />
Material:<br />
Vertical frame sections:<br />
Extruded aluminium section,<br />
roof frame<br />
Panels: Sheet steel<br />
Surface finish:<br />
Enclosure panels/door trim<br />
panel:<br />
Spray-finished in RAL 7035<br />
Frame sections, perforated plate<br />
of front/rear door: RAL 9006<br />
482.6 mm (19″) mounting<br />
angles, mounting frame:<br />
Zinc-plated, passivated<br />
Supply includes:<br />
System frame section FR(i) 1) with<br />
designer door, vented, TS sheet<br />
steel door at rear, vented, levelling<br />
feet, stabiliser, earthing of<br />
all enclosure panels,<br />
comfort handles for semi-cylinder<br />
and/or knob handle with<br />
security lock 3524 E.<br />
Property rights:<br />
German patent no. 103 11 376<br />
German registered design<br />
no. 403 04 312<br />
British registered design<br />
no. 301 54 31<br />
Detailed drawing,<br />
available on the Internet.<br />
U 24 42 24 42<br />
Width (B1) mm 3) 600 600 600 600<br />
Height (H1) mm 3) 1200 2000 1200 2000<br />
Depth (T1) mm 3) 1005 1005 1205 1205<br />
Depth absolute, including handles and curvature (T1) mm + 75 mm 3) 1080 1080 1280 1280<br />
Maximum distance between levels (T2) mm 3) 829 829 1029 1029<br />
Distance between the 482.6 mm (19″) levels (T3) mm 3) 750 750 850 850<br />
Model No. FR(i) as bayed enclosure without side panels, without baying kit 7855.310 7855.330 7855.312 7855.332<br />
Doors<br />
Designer door, front, vented 2) <br />
TS sheet steel door, rear, vented 2) <br />
Roof<br />
Roof plate, solid – –<br />
Roof plate with cable entry openings in the corners – – <br />
Floor<br />
Levelling feet <br />
Stabiliser, pull-out <br />
Open base, without base frame <br />
Interior installation<br />
482.6 mm (19″) mounting angles, front <br />
482.6 mm (19″) mounting frame, rear <br />
Earthing of all enclosure panels on the enclosure frame <br />
Central earthing point fitted at the rear of the base frame <br />
Accessories<br />
2 designer side panels IP 20, including security lock 3524 E 7856.672 7856.687 7856.673 7856.688<br />
Transport kit, 4 castors including assembly parts 7825.900 7825.900 7825.900 7825.900<br />
Included with the supply. 1) The system frame FR(i) is generally suitable for the installation of TS 8 accessories.<br />
2) Vented surface area 67 % perforated. 3) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
Accessories Page 252 Liquid cooling Page 129 Baying system Page 270<br />
Rittal IT catalogue/Server racks<br />
87
Server racks<br />
Based on Rittal TS 8, High Performance Cooling systems HPC<br />
T1<br />
B1<br />
B2<br />
Server racks<br />
H2<br />
H1<br />
T2<br />
High Performance Cooling<br />
Systems HPC:<br />
Glazed door at the front, (180°),<br />
with 3 mm single-pane safety<br />
glass, sheet steel door at the<br />
rear, (130°), comfort handle for<br />
semi-cylinder and security lock<br />
3524 E on both sides.<br />
482.6 mm (19″) mounting frame<br />
front and rear, distance between<br />
levels pre-configured 740 mm,<br />
free space to front door approx.<br />
100 mm, max. load capacity of<br />
the interior installation 1000 kg<br />
per rack.<br />
Roof plate, two-piece,<br />
for cable entry via sliding plate.<br />
Multi-divided base/gland plate.<br />
Maximum attainable protection<br />
category IP 55, in conjunction<br />
with solid roof (bayed solution)<br />
and additional screw-fastened<br />
side panels with stand-alone<br />
siting.<br />
Material:<br />
Sheet steel<br />
Surface finish:<br />
Dipcoat-primed, panels additionally<br />
powder-coated,<br />
RAL 7035.<br />
Gland plates and 482.6 mm<br />
(19″) mounting frame zincplated,<br />
passivated.<br />
Supply includes:<br />
Enclosure frame with doors and<br />
rear panel, roof plate, gland<br />
plate, 482.6 mm (19″) interior<br />
installation, earthing of all panels,<br />
levelling feet, fitted.<br />
U 42 42 42 42<br />
Width (B1) mm 1) 600 800 600 800<br />
Height (H1) mm 1) 2000 2000 2000 2000<br />
Depth (T1) mm 1) 1000 1000 1200 1200<br />
Clearance width (B2) mm 512 712 512 712<br />
Clearance height (H2) mm 1912 1912 1912 1912<br />
Clearance depth (T2) mm 512 712 512 712<br />
Model No. DK as bayed enclosure without side panels, without baying kit 7931.810 7931.800 7931.812 7931.802<br />
Model No. DK with side panels, screw-fastened – – 7931.813 7931.803<br />
Doors<br />
Designer glazed front door, sheet steel rear door <br />
Roof<br />
Roof plate for cable entry, two-piece <br />
Floor<br />
Levelling feet <br />
Base frame with multi-piece gland plate <br />
Interior installation<br />
482.6 mm (19″) levels, front and rear <br />
L-shaped mounting angles – – – –<br />
Mounting angles attached to depth stays – – – –<br />
482.6 mm (19″) mounting frames, front and rear <br />
Panel earthing, fitted <br />
Accessories<br />
Side panel, screw-fastened, IP 55 8100.235 8100.235<br />
<br />
<br />
(7931.813 only) (7931.803 only)<br />
Depth-variable slide rail, 1 U 7063.883 7063.883 7063.883 7063.883<br />
482.6 mm (19″) heavy duty base, 700 mm deep, 100 kg load capacity 1) 7063.897 7063.897 7063.897 7063.897<br />
Installation kit for heavy-duty component shelf, depth-variable 7063.890 7063.890 7063.890 7063.890<br />
Included with the supply. 1) All sizes are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
Accessories Page 252 Baying system Page 270<br />
88 Rittal IT catalogue/Server racks
Smart Package<br />
Based on Rittal TS 8, pre-configured<br />
Smart Package A1<br />
The solution for climate-controlled rooms<br />
The perforated sheet steel doors at the front and<br />
rear provide for reliable ventilation of the racks,<br />
with 78 % of the door surface area available for air<br />
throughput.<br />
A brush strip in the plinth and the sliding panel in<br />
the base frame permits simple cable entry even<br />
with pre-assembled plug connectors.<br />
Power supply<br />
The integrated PSM busbar with 6 x IEC 320 PSM<br />
modules is a VDE-approved power distribution<br />
system.<br />
As IEC 60 320 modules are used, it is not possible<br />
to transpose the phase and neutral conductors.<br />
The two infeeds to the PSM busbar permit both<br />
the mains voltage and a UPS voltage to be made<br />
available in the rack. The colour-coding of the C13<br />
modules serves for differentiation (UPS = red).<br />
Technical specifications:<br />
● Cooling output for a 10 K temperature difference:<br />
1.5 kW<br />
● Nominal UPS output: 2 kVA<br />
● UPS input voltage: 160 – 276 V AC<br />
● Autonomy time at 100 % load: 7 min.<br />
● Infeed: 400 V AC, 3 x 16 A, CEEkon<br />
● Protocols: HTTP, SNMP, Telnet, SMTP<br />
Benefits at a glance:<br />
● Built-in 2 kVA UPS VFI-SS-111<br />
● VDE-approved power distribution<br />
● Mains and UPS voltage available on the PSM<br />
busbar<br />
T<br />
Width (B) 800 mm<br />
Height (H1) 2000 mm<br />
Overall height (H2) 2100 mm<br />
Depth (T) 1000 mm<br />
B<br />
H1<br />
H2<br />
Smart Package<br />
A glazed front door and a sheet steel rear door,<br />
together with a vented plinth, ensure that the prescribed<br />
air routing is maintained. A brush strip in<br />
the plinth and the sliding panel in the base frame<br />
permits simple cable entry even with pre-assembled<br />
plug connectors.<br />
B<br />
Smart Package A2<br />
The solution for the office sector<br />
Quiet-running roof-mounted fans with speed control<br />
functionality achieve active rack cooling at<br />
exceptionally low noise levels. Heat losses of up<br />
to 2.0 kW can be dissipated.<br />
Technical specifications<br />
● Cooling output for a 10 K temperature difference:<br />
2.0 kW<br />
● Nominal UPS output: 3 kVA<br />
● UPS input voltage: 160 – 276 V AC<br />
● Autonomy time at 100 % load: 5 min.<br />
● Infeed: 400 V AC, 3 x 16 A, CEEkon<br />
● Monitoring: Temperature, smoke, access<br />
● Protocols: HTTP, SNMP, SSH, Telnet, PPP, SMTP<br />
Benefits at a glance:<br />
● Optimised air routing for servers and PCs<br />
● Quiet roof-mounted fan, supplied ready-wired:<br />
Noise level 40 dB (A)<br />
● 3 kVA UPS VFI-SS-111<br />
● Mains and UPS voltage available on the PSM busbar<br />
● Temperature monitoring, smoke alarm and<br />
access control<br />
H2<br />
H1<br />
Width (B) 800 mm<br />
Height (H1) 2000 mm<br />
Overall height (H2) 2340 mm<br />
Depth (T) 1000 mm<br />
T<br />
permits IT infrastructures to be installed at locations<br />
subject to high levels of contamination or high<br />
ambient temperatures. This Smart Package server<br />
rack is able to dissipate heat losses of up to 3 kW<br />
at an ambient temperature of 35°C.<br />
T2<br />
T<br />
B<br />
Smart Package A3<br />
The server rack to IP 54<br />
With the cooling unit at the rear, a glazed front<br />
door, a sheet steel rear door and screw-fastened<br />
side panels, this rack represents a closed system<br />
and<br />
Technical specifications<br />
● Cooling output at 35°C ambient temperature:<br />
3kW<br />
● Nominal UPS output: 3 kVA<br />
● UPS input voltage: 160 – 276 V AC<br />
● Autonomy time at 100 % load: 5 min.<br />
● Infeed: 400 V AC, 3 x 32 A, CEEkon<br />
● Monitoring: Temperature, smoke, access<br />
● Protocols: HTTP, SNMP, SSH, Telnet, PPP, SMTP<br />
Benefits at a glance:<br />
● Optimised air routing for servers and PCs<br />
● IP 54<br />
● 3 kVA UPS VFI-SS-111<br />
● Mains and UPS voltage available on the PSM<br />
busbar<br />
● Temperature monitoring, smoke alarm and<br />
access control<br />
H2<br />
H1<br />
Width (B) 800 mm<br />
Height (H1) 2000 mm<br />
Overall height (H2) 2100 mm<br />
Depth (T) 1000 mm<br />
Overall depth (T2) 1350 mm<br />
Rittal IT catalogue/Server racks<br />
89
Smart Package<br />
Based on Rittal TS 8, pre-configured<br />
A1 A2 A3<br />
Smart Package<br />
1<br />
2<br />
3<br />
4<br />
Model No. DK 7337.100 7337.200 7337.300<br />
Description Cooling by convection Cooling using a roof-mounted fan Cooling using a cooling unit<br />
Available U 36 35 33<br />
Width (B) mm 1) 800 800 800<br />
Height (H) mm 1) 2100 2340 2100<br />
1<br />
Depth (T1) mm 1) 1000 1000 1350<br />
Technical specifications<br />
Cooling output<br />
for a temperature difference of for a temperature difference of at 35°C ambient temperature:<br />
10 K: 1.5 kW<br />
10 K: 2.0 kW<br />
3 kW<br />
Nominal UPS output 2 kVA 3 kVA 3 kVA<br />
UPS input voltage 160 – 276 V AC 160 – 276 V AC 160 – 276 V AC<br />
Autonomy at 100 % load approx. 7 min 5 min 5 min<br />
Three-phase infeed 400 V AC, 16 A, CEE 400 V AC, 16 A, CEE 400 V AC, 32 A, CEE<br />
Monitoring – Temperature, smoke, access Temperature, smoke, access<br />
Protocols HTTP, SNMP, Telnet, SMTP HTTP, SNMP, Telnet, SSH, PPP, SMTP HTTP, SNMP, Telnet, SSH, PPP, SMTP<br />
Assembled supply<br />
2<br />
7<br />
4<br />
1<br />
5<br />
6<br />
3<br />
2<br />
3<br />
5<br />
9<br />
8<br />
6<br />
7<br />
4<br />
1<br />
1<br />
2<br />
3<br />
4<br />
Sheet steel door, vented<br />
2 U drawer<br />
PSM busbar<br />
UPS, 2 kVA, with battery<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Roof-mounted fan<br />
(not pre-installed)<br />
Glazed door<br />
Sheet steel door<br />
2 U drawer<br />
PSM busbar<br />
UPS, 3 kVA, with battery<br />
CMC-TC PU II<br />
CMC-TC I/O Unit<br />
1 Cooling unit<br />
2 Comfort handle<br />
3 Glazed door<br />
4 Sheet steel door<br />
5 2 U drawer<br />
6 PSM busbar<br />
7 UPS, 3 kVA, with battery<br />
8 CMC-TC PU II<br />
CMC-TC I/O Unit<br />
9<br />
Air routing tunnel, 2 U<br />
Optional accessories, not pre-installed Packs of Model No. DK Page<br />
Monitor/keyboard unit, 1 U, 17″ TFT display, German 1 9055.300 190<br />
SSC view 8 (KVM switch in conjunction with monitor/keyboard unit) 1 7552.000 191<br />
CPU cable 2 m (server connection cable for Rittal SSC KVM switch) 1 7552.120 196<br />
CPU cable 4 m (server connection cable for Rittal SSC KVM switch) 1 7552.140 196<br />
Depth-variable slide rails, 1 U, length 590 – 930 mm 2 7063.884 384<br />
Component shelf 1 / 2 U, depth-variable 1 7063.720 322<br />
Component shelf, heavy duty, depth 500 mm 1 7063.895 321<br />
Installation kit, depth-variable, for component shelf, heavy duty 1 7063.890 324<br />
Telescopic slides for component shelf, heavy duty 1 7065.000 326<br />
Component shelf, static installation for 19″ level (depth 250 mm) 1 7119.250 323<br />
Component shelf, static installation for 19″ level (depth 400 mm) 1 7119.400 323<br />
Shunting rings 300 x 90 mm 4 7220.600 355<br />
Light 1 U (for 482.6 mm (19″) installation) 1 7109.200 335<br />
PSM plug-in module IEC 60 320 4 x C19 (max.16 A) 1 7856.230 100<br />
Light module PSM 1 7856.210 100<br />
Active Power System Module 8-way, individually switchable 1 7856.201 101<br />
Additional RCCMD licence (for server shutdown) 1 7857.421 434<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing on the Internet.<br />
90 Rittal IT catalogue/Server racks
Smart Package<br />
Based on Rittal TS 8, pre-configured<br />
A1 A2 A3 Page<br />
Model No. DK 7337.100 7337.200 7337.300<br />
Available U 38 37 34<br />
Width (B) mm 1) 800 800 800<br />
Height (H2) mm 1) 2100 2340 2100<br />
Depth (T or T2) mm 1) 1000 1000 1350<br />
Supply includes<br />
Doors<br />
Sheet steel door, vented, with comfort handle, front – – 279<br />
Glazed door with comfort handle, front – 278<br />
Sheet steel door, vented, with swivel handle, rear – – 279<br />
Sheet steel door with swivel handle, rear – 277<br />
Side panels<br />
Side panel, plug-in, IP 20 – 266<br />
Lock for side panel, plug-in (3524 E) – 266<br />
Side panel, screw-fastened, IP 54 – – 265<br />
Roof<br />
Roof plate, solid – <br />
Roof plate, vented – – 293<br />
Base<br />
Base/plinth, solid with brush strip for cable entry at the rear – 255<br />
Base/plinth, vented with brush strip for cable entry at the rear – – 255<br />
Gland plate, multi-piece – 263<br />
Gland plate, one-piece, vented, for TS – – 263<br />
Filter mat for gland plate, one-piece – – 263<br />
Interior installation<br />
482.6 mm (19″) level, front and rear 316<br />
Drawer, 2 U 385<br />
Power<br />
PSM busbar, installation height 2000 mm,<br />
including mounting kit for a maximum of 7 standard modules<br />
99<br />
Plug-in module PSM 6 x C13 (IEC 320 appliances, black) 2 2 2 100<br />
Plug-in module PSM 6 x C13 (IEC 320 appliances, red) 2 2 2 100<br />
Cooling<br />
Roof-mounted fan (low-noise, speed-controlled), supplied ready wired – – 126<br />
Cooling unit with adjusted airflow – – 138<br />
UPS<br />
Double conversion UPS, classification: VFI-SS-111 104<br />
2 kVA including battery and SNMP card – – 434<br />
3 kVA including battery and SNMP card – 434<br />
Security/monitoring<br />
CMC-TC PU II including power pack and mounting kit (1 U) – 158<br />
Programming cable – 169<br />
CMC-TC I/O unit – 160<br />
Temperature sensor, smoke alarm and access sensor – 172<br />
Digital sensor input module (cooling unit monitoring) – – 174<br />
Cable kit/mounting kit – 169<br />
Standard accessories, supplied loose<br />
Connection cable (3-phase) 16 A 16 A 32 A 167<br />
IEC 320 appliances extension 0.5 m and 1 m, each 5 5 5 167<br />
Cable lock C13 20 20 20 100<br />
Nylon loop cable tie 20 20 20 353<br />
RCCMD licence (server shutdown software) 1 1 1 434<br />
Included with the supply.<br />
1) All sizes given are nominal dimensions. For absolute dimensions, please refer to the detailed drawing.<br />
Smart Package<br />