Kemlux II Brochure - Hubbell Industrial Lighting

hubbellindustrial.com

Kemlux II Brochure - Hubbell Industrial Lighting

HUBBELL LIGHTING

KEMLUX ®

II KS/KH SERIES.

THE HARSH/HAZARDOUS

LIGHTING SOLUTION.

®


The harsh/hazardous lighting solution.

Hubbell Lighting has the answer for your demanding lighting environments.

The Kemlux II KS/KH lighting fixture meets your wet, harsh,

corrosive, or hazardous needs.

The Kemlux II KS/KH Series utilizes the Electro-Reg ® ballast to give long

life and reliable operation for metal halide lamps.

The KS meets the demands of UL and CSA listed wet locations and

NEMA 4 hosedown. The KH Series is designed for hazardous locations

defined by Article 500 of the NEC ® and UL 595 Marine.

APPLICATIONS

Kemlux KS lighting fixtures are used:

• In manufacturing plants where moisture, corrosives,

washdown and heavy vibration are present.

• In wastewater and sewage treatment plant facilities, cement

plants, pulp and paper mills, steel mills, power plants and

other heavy industrial installations.

• In any area involving adverse/severe environments.

Kemlux KH lighting fixtures are used:

• In areas where ignitable concentrations of gases or vapors are

present in abnormal conditions.

• In areas involving combustible dust.

• In refineries, chemical plants, steel mills, offshore platforms, grain

silos, pharmaceuticals or wherever there is the potential presence of

gases, vapors and ignitable dusts.

FEATURES

Electro-Reg ® metal halide

ballast availability for

KS/KH

KS is rated NEMA 4

hosedown

KH is UL 595 Marine

listed

KH components are

UL 844 listed

KS/KH medium housing

with globe optic can ship

in components,Unit Pack

or Factory Assembled

White Lektrocote ® finish

with copper-free

aluminum housing

(consult factory for

gray finish)

BENEFITS

• Long lamp life benefits of HPS,

but with white light which saves

maintenance dollars and creates

pleasant working environment.

• 2 minute re-strike time – less

downtime and improved safety.

• Low lumen depreciation over life

of lamp means fewer initial fixtures

needed and lower installed costs –

saves money.

• UL listed ensures safety.

Reliable operation in hosedown, wet,

damp locations – low maintenance.

Reliable operation in Marine, hosedown,

wet, damp installations – low

maintenance.

Components can be interchanged in

the field for faster delivery and

minimum downtime.

Flexibility in material receiving for

ease of installation, saving time

and money.

Excellent corrosion resistance in

severe environments means low

operating temperatures, improved

photometrics, good performance.

TYPICAL KH DATA MARKER

• Allows field component interchangeability

– lowers maintenance costs

• Displays accurate T-Ratings

– helps ensure safe performance

Ballast housing

catalog number

Available

optics

T-Ratings

Available

mounting

covers

Re-designed Data Marker

for KH

Size reduction of large

housing

Allows component interchangeability

in the field, displays accurate

T-Ratings, lowers maintenance

costs and helps ensure safe

performance.

Smaller size and lighter weight

means ease of installation, saving

time and money.

ELECTRO-REG ® BENEFITS

• Extended lamp life of metal halide lamps. 50%+ for all

wattages. Saves money in maintenance costs.

• Lower Lumen Lamp Depreciation over lamp life. Fewer initial

fixtures needed (up to 30% for 3 shift operation), saving

money in installation and maintenance costs.

• Up to 58% voltage drop tolerance for voltage dip conditions.

Maintains safe lighting levels and diminishes downtime.

• 2-3 minute hot restart time, re-establishing safe working

environment in short time period.

• Minimum color shift over lamp life, maintaining good

color rendition.

• Provides white light, with maintenance and operating

benefits of high pressure sodium.

Hubbell 2


KS

UL 1572: wet locations

NEMA 4: hosedown

CSA NRTL/C: CSA

C22.2 no. 90-96

55°C Ambient

KH

UL 844: fixtures for use in hazardous

(classified) locations

Class I, Division 2: Groups A, B, C, D

Class II, Division 1 and 2: Groups E, F, G*

Class III

UL 595: Marine

UL 1572: wet locations

IP66: self-certified

CSA NRTL/C: CSA C22.2 no. 90-96 and

no. 137-M1981

* see T-Ratings for Group G listing

Now available, Electro-Reg ® metal halide

ballast which provides long life, quick

re-strike, and low lumen depreciation for

metal halide lamps. Provided as an option.

Available in metal halide (175, 250, 400

watt); high pressure sodium (50, 70, 100,

150, 250, 400 watt) and mercury vapor

(100, 175, 250, 400 watt) light sources.

Mogul base socket.

Rugged die cast copper-free (less than

0.4%) aluminum housing provides

excellent corrosion resistance in the

most severe environments.

Durable white Lektrocote ® powder

polyester finish is electrostatically

applied and thermally set for superior

corrosion resistance.

Efficient heat sink design for cool operation

and long ballast life.

Heavy-duty covers accommodate rigid

pendant, flexible pendant, ceiling, wall

and 25° angled orientation for

stanchion configurations.

All covers have four point closure for

positive seal.

All external mounting hardware is

stainless steel or Hubbell Gard ® .

Thermal shock and impact-resistant

glass globes, symmetrical

and asymmetrical borosilicate

glass refractors, and 19"

enclosed reflectors offer

complete versatility in

lighting design.

Class H insulated, high

power factor ballasts for

metal halide, high pressure

sodium, and mercury vapor

provide dependable performance.

Minimum starting temperature is -20°F for

MH/MV and -40°F for HPS.

Unit Pack and Factory Assembled

(lamp/globe installed) packaging allows

for ease of installation.

KS/KH SHOWN WITH GLOBE, GUARD AND DOME

Hubbell 3


SPECIFYING HAZARDOUS LIGHTING

Many factors go into specifying hazardous

lighting. Care must be taken in determining

the classification of the hazardous location in

which the fixtures are being installed. Any

qualified inspector, underwriter or fire marshall

can help determine a Classification of an

area. The decisions which must be made are:

KS/KH VARIATIONS

CLASS (type of substance)

Class I Gas or Vapor

Class II Combustible Dust

Class III Ignitable Fibers and Flyings

GROUP (nature of substance)

CLASS I Group A Test Gas Acetylene

Group B Test Gas Hydrogen

Group C Test Gas Ethylene

Group D Test Gas Propane

The main factor in determining gas groups

is the maximum explosive pressure of the

gas. Group A is the gas group with most

explosive pressure. Group D is the least.

CLASS II Group E Metallic Dusts

Group F Carbonaceous Dusts

Group G Grain Dusts

The main factor in determining dust groups

is material resistance and dust particle size.

CLASS III No Groups

KS/KH SHOWN WITH

GLOBE AND GUARD

DIVISION (occurrence of substance)

DIVISION 1 Hazardous area under normal

operating conditions.

(Example: manufacturing plant

using polypropylene to

manufacture end product.)

DIVISION 2 Hazardous area under

abnormal operating conditions.

(Example: storage tank farm.)

TEMPERATURE RATINGS (T-Ratings)

DEFINED

Maximum operating temperature of a fixture.

Class I and II, Division 1: T-Rating measured

externally.

Class I, Division 2: T-Rating measured

internally.

OBJECTIVE:

• Determine safe T-Rating requirement of

fixture for working environment.

• Specify fixture with equal or lower T-Rating

(per NEC ® Table 500-3[d]).

• The T-Rating determines the type (Division 1

or 2), wattage or light source of fixture to

be specified.

• See T-Ratings of Kemlux II on Page 6.

KS/KH SHOWN WITH GLOBE

AND ANGLE DOME

TABLE NEC ® 500-3(d)

IDENTIFICATION

MAXIMUM TEMPERATURE

NUMBER C° F°

T1 450 842

T2 300 572

T2A 280 536

T2B 260 500

T2C 230 446

T2D 215 419

T3 200 392

T3A 180 356

T3B 165 329

T3C 160 320

T4 135 275

T4A 120 359

T5 100 212

T6 85 185

KS/KH SHOWN WITH

REFLECTOR/POLYCARBONATE

REFRACTOR


Ordering Information

Kemlux ®

II

KS/KH Series

SAMPLE CATALOG NUMBER

KH - 15 S 8 - G - P2 -

RS

Series

Wattage

Lamp

Type

Voltage

Optical

Assembly

Mounting

Options

COMPONENT ORDERING INFORMATION

SERIES

KS Harsh/Severe

KH Hazardous

WATTAGE

MEDIUM HOUSING

50 50 watt HPS

70 70 watt HPS

10 100 watt MV or HPS

15 150 watt HPS

17 175 watt MV, MH or

Electro-Reg ® MH

25 250 watt MV or MH

LARGE HOUSING

25* 250 watt HPS

40 400 watt MV, MH, HPS, or

Electro-Reg MH

* 250 watt Electro-Reg MH. Consult factory.

LAMP TYPE

C Mercury Vapor

H Metal Halide

S High Pressure Sodium

E Electro-Reg Metal Halide

VOLTAGE

1 120V (50 watt HPS &

Electro-Reg only)

2 208V (Electro-Reg)

3 240V (Electro-Reg)

4 277V (50 watt HPS &

Electro-Reg only)

5 480V (not available for

50 watt HPS)

6 Tri-Tap ® (120, 277, 347V)

(not available for Electro-Reg)

8 Quad-Tap ®

(120, 208, 240, 277V)

(not available for Electro-Reg)

E 220/240V 50Hz

(not available for Electro-Reg)

F 347V (Electro-Reg)

OPTICAL ASSEMBLY

MEDIUM HOUSING ONLY

G Globe

X Reflector/Polycarbonate

Refractor

MEDIUM OR LARGE HOUSING

L Symmetrical Glass Refractor

LARGE HOUSING ONLY

M Asymmetrical Glass Refractor

E Enclosed Reflector

MOUNTING

B2 3

⁄4" Balancing Pendant (KS only)

B6 3

⁄4" Balancing Pendant/Electro-Reg

(KS only)

C2 3

⁄4" Ceiling

C3 1" Ceiling

D4 1 1 ⁄4" Stanchion

D5 1 1 ⁄2" Stanchion

D8 1 1 ⁄4" Stanchion/Electro-Reg

D9 1 1 ⁄2" Stanchion/Electro-Reg

P2 3

⁄4" Pendant

P3 1" Pendant

P6 3

⁄4" Pendant/Electro-Reg

P7 1" Pendant/Electro-Reg

W2 3/4" Wall

W6 3/4" Wall/Electro-Reg

OPTIONS

F(X) 1 Fusing (X indicates voltage)

QS Quartz Standby (KS only)

QT Time Delay Quartz Standby

(KS only)

RS Hot Restrike

(70-150 watt HPS only)

PC Photocontrol (KS only)

(not available for ceiling)

UP Unit Pack-Mounting Adapter,

Ballast Housing, Globe in same

carton (medium housing only)

FA Factory Assembled, Lamp and

Globe installed into Ballast

Housing, includes Mounting

Adapter (medium housing only)

NOTE: See Accessories for guards, dome/angle reflector.

1 To specify correct voltage replace X with 1-120V,

2-208V, 3-240V, 4-277V, 5-480V, 6-347V.

KS/KH 2 SERIES BALLAST HOUSING

Wattage Voltage Catalog Number

High Pressure Mercury Vapor Metal Halide

Sodium PLA Electro-Reg

50W 120 KS50S1 — —

277 KS50S4 — —

70W 120/208/240/277 KS70S8 — —

480 KS70S5 — —

100W 120/208/240/277 KS10S8 KS10C8 —

480 KS10S5 KS10C5 —

150W 120/208/240/277 KS15S8 — —

480 KS15S5 — —

175W 120/208/240/277 — KS17C8 KS17H8 KS17EX 3

480 — KS17C5 KS17H5 KS17E5

250W 120/208/240/277 KS25S8 KS25C8 KS25H8 KS25EX 3

480 KS25S5 KS25C5 KS25H5 KS25E5

400W 120/208/240/277 KS40S8 KS40C8 KS40H8 KS40EX 3

480 KS40S5 KS40C5 KS40H5 KS40E5

2 For KH Series, change S to H in catalog number. Example KH15S8.

3 Replace X with voltage. Example KS17E1 (120V). See VOLTAGE.

KS/KH SERIES MOUNTING ADAPTERS

Catalog Number Description Hub Plugs Weight

KS KH Size Quantity Quantity lbs. kg

KS-P2 KH-P2 Pendant 3

⁄4" 1 — 1.5 0.7

KS-P3 KH-P3 Pendant 1" 1 — 1.5 0.7

KS-C2 KH-C2 Ceiling (also for Electro-Reg) 3

⁄4" 4 3 2.0 0.9

KS-C3 KH-C3 Ceiling (also for Electro-Reg) 1" 4 3 2.0 0.9

KS-D4 KH-D4 25° Stanchion 1 1 ⁄4" 1 — 4.0 1.8

KS-D5 KH-D5 25° Stanchion 1 1 ⁄2" 1 — 4.0 1.8

KS-W2 KH-W2 Wall 3

⁄4" 4 3 4.0 1.8

KS-B2 Balancing Pendant 3

⁄4" 1 — 2.0 0.9

KS-P6 4 KH-P6 4 Pendant Electro-Reg 3

⁄4" 1 — 4.5 2.0

KS-P7 4 KH-P7 4 Pendant Electro-Reg 1" 1 — 4.5 2.0

KS-D8 KH-D8 25° Stanchion Electro-Reg 1 1 ⁄4" 1 — 4.5 2.0

KS-D9 KH-D9 25° Stanchion Electro-Reg 1 1 ⁄2" 1 — 4.5 2.0

KS-W6 KH-W6 Wall Electro-Reg 3

⁄4" 1 — 4.5 2.0

KS-B6 Balancing Pendant Electro-Reg 3

⁄4" 1 — 2.5 1.1

4 Same adapter as ceiling mount except one drilled and tapped entry on top and blank entries on sides.

KS/KH SERIES OPTICS

Catalog Description Weight

Number lbs. kg

K-G Prismatic, heat-resistant Glass Globe (medium housing only) 2.0 1.0

K-E 19" Enclosed Reflector (large housing only) 7.0 3.2

K-L Symmetrical (Type V) Glass Refractor 13.0 5.9

K-M Asymmetrical (Type II) Glass Refractor (large housing only) 13.0 5.9

K-X Reflector/Polycarbonate Refractor (medium housing only) — —

ACCESSORIES must be ordered separately

Catalog Description Weight

Number lbs. kg

K-10 Cast Guard for K-G globe (not for use with angle reflector) 1.0 0.5

K-11 Steel Wire Guard for K-05 30° angle reflector 1.0 0.5

K-20 Steel Wire Guard for K-L and K-M glass refractors (zinc plated) 2.0 1.0

K-30 Steel Wire Guard for K-E enclosed reflector (painted) 1.0 0.5

K-04 Standard Dome Reflector for K-G globe (plastic) 1.0 0.5

K-05 30° Angle Reflector (without guard) 1.0 0.5

K-15 30° Angle Reflector for K-G globe (with guard, painted steel) 1.0 0.5

K-SC6 6' safety chain (large housing only) — —

4

Hubbell

UNIT PACK

see UP option

FACTORY ASSEMBLED

see FA option


MEDIUM HOUSING

4 3 /4"

(121mm)

14 1 /2"

5 5 /8" (368mm)

(143mm)

4 3 /4"

(121mm)

11 1 /2"

(292mm)

16 1 /4"

(413mm)

4 3 /4"

(121mm)

10 1 /4"

(260mm)

15"

(381mm)

16 3 /8"

(416mm)

GLOBE, GUARD, DOME

16"

(406mm)

REFLECTOR/POLYCARBONATE REFRACTOR

11 1 /4"

(286mm)

GLOBE, ANGLE DOME

LARGE HOUSING

HOUSING AND MOUNTING HUB

PLAN VIEW

6 1 /16"

(154mm)

6 1 /16"

(154mm)

12 5 /8"

(298mm)

22 1 /4"

(565mm)

4 1 /8"

(105mm)

10"

(254mm)

3 1 /2"

(89mm)

7 9 /16"

(192mm)

19 9 /16"

(497mm)

12 1 /4"

(311mm)

7 1 /16"

(194mm)

19"

(483mm)

13 1 /4"

(337mm)

ENCLOSED REFLECTOR GUARD

REFRACTOR GUARD

MOUNTING HUBS

CEILING MOUNTING HUB

12 1 /4"

(311mm)

KS-P2 KS-P3

KH-P2 KH-P3

7 /8"

(22mm)

2 3 /16"

(56mm)

13 1 /2"

(343mm)

10"

(254mm)

KS-C2 KS-C3 KS-P6 KS-P7

KH-C2 KH-C3 KH-P6 KH-P7

13 1 /2"

(343mm)

2"

(51mm)

2"

(51mm)

3 5 /16"

(81mm)

12 1 /4"

(311mm)

KS-B6

KS-B2

3 3 /4"

(85mm)

4 9 /16"

(116mm)

12 1 /4"

(311mm)

KS-D4 KS-D5

KH-D4 KH-D5

17 1 /8"

(435mm)

13 1 /2"

(343mm)

17 5 /8"

(448mm)

KS-W6 KH-W6

3 3 /4"

(95mm) 4 9 /16"

(116mm)

12 1 /4"

(311mm)

KS-W2

KH-W2

16 1 /2"

(419mm)

4 7 /16"

(112mm)

13 1 /2"

(343mm)

18 1 /4"

(464mm)

KS-D8 KS-D9 KH-D8 KH-D9

Hubbell 5


Temperature Ratings (T-Ratings)

Kemlux ®

II

KH Series

HAZARDOUS LOCATION APPLICATION DATA: HIGH PRESSURE SODIUM

Configuration Class I, Division 2 1 Class II, Div. 1 & 2 3 –Class III, Div. 1 & 2 Maximum

Class Max. Lamp Temp. Group(s) Max. Ext. Surface Temp. Ambient

Temp. Rating °C Code Temp. Rating °C Code

K-G / K-10 / K-04 / K-05 / K-15 GLASS GLOBE & GUARD INCLUDING ANGLE & DOME

HPS 50W 200 T3 E, F, G 165 T3B 40°C

HPS 70W 200 T3 E, F, G 160 T3C 12 40°C

HPS 100W 215 8,10 T2D 8,10 E, F, G 4 160 9 T3C 5 40°C

HPS 150W 260 6,11 T2B 6,11 E, F, G 4 160 9 T3C 5 40°C

K-L GLASS REFRACTOR AND GUARD 2 12" DIAMETER

HPS 50W 180 T3A E, F, G 160 T3C 40°C

HPS 70W 180 T3A E, F, G 160 T3C 40°C

HPS 100W 200 T3 E, F, G 160 T3C 40°C

HPS 150W 230 T2C E, F, G 160 T3C 40°C

HPS 250W 280 9 T2A E, F, G 9 160 T3C 40°C

HPS 400W 350 9 7 E, F, G 9 160 T3C 40°C

K-E ENCLOSED REFLECTOR / K-M ASYMMETRICAL GLASS REFRACTOR AND GUARD

HPS 250W 280 9 T2A E, F, G 9 160 T3C 40°C

HPS 400W 350 9 7 E, F, G 9 160 T3C 40°C

HAZARDOUS LOCATION APPLICATION DATA: HIGH PRESSURE SODIUM

Configuration Class II, Div. 2 – Group G 3 Maximum

Class Max. Ext. Surface Temp. Ambient

Temp. Rating °C

Code

K-X POLYCARBONATE REFRACTOR 16" DIAMETER

HPS 50W 85 T6 40°C

HPS 70W 85 T6 40°C

HPS 100W 85 T6 40°C

HPS 150W 85 T6 40°C

1 Lamp temperature data was obtained in 40°C ambient under normal operating conditions

2 Applies to symmetrical and asymmetrical glass refractors

3 Luminaire maximum surface temperature data was obtained under a dust blanket at 40° ambient under normal

operating conditions

4 Stanchion mount with dome reflector unit suitable for Groups E, F, & G, all other mounting styles in this

classification with or without dome or angle reflector suitable for Groups E & F only

5 External temperature and group code for stanchion mount with dome reflector, for all other luminaire

combinations in this classification temperature is 180/T3A

6 When used with angle reflector, temperature is 280/T2A

7 No T code available for 325°C or 350°C temperature ratings

8 When used with angle reflector, temperature is 230/T2C

9 RS option not available

10 RS option K-G with K-04 – temperature is 215/T2D, with K-G, K-05, temperature is 230°C/T2C

11 RS option K-G temperature is 300°/T2

12 If used with K-05 temperature code is T3B, 165°C, if used with K-G without K-1, temperature code is T3B/165°C

HAZARDOUS LOCATION APPLICATION DATA: METAL HALIDE & ELECTRO-REG

Configuration Class I, Division 2 1 Class II, Div. 1 & 2 5 –Class III, Div. 1 & 2 Maximum

Class Max. Lamp Temp. Group(s) Max. Ext. Surface Temp. Ambient

Temp. Rating °C Code Temp. Rating °C Code

K-G / K-5 / K-10 / K-04 / K-15 GLASS GLOBE & GUARD INCLUDING ANGLE & DOME

MH 175W 280 10 T2A 10 E, F, G 6 160 7 T3C 7 40°C

MH 250W 325 2 11 E, F 8 200 T3 40°C

K-L GLASS REFRACTOR AND GUARD 4 12" DIAMETER

MH 175W 260 T2B E, F, G 160 T3C 40°C

MH 250W 300 T2 E, F, G 160 T3C 40°C

MH 400W 300 T2 E, F 180 T3A 40°C

K-E ENCLOSED REFRACTOR AND GUARD

MH 175W 260 T2B E, F, G 160 T3C 40°C

MH 250W 300 T2 E, F, G 160 T3C 40°C

MH 400W 300 T2 E, F, G 160 T3C 40°C

K-M ASYMMETRICAL GLASS REFRACTOR AND GUARD

MH 400W 300 T2 E, F 180 T3A 40°C

HAZARDOUS LOCATION APPLICATION DATA: MERCURY VAPOR

Configuration Class I, Division 2 1 Class II, Div. 1 & 2 5 –Class III, Div. 1 & 2 Maximum

Class Max. Lamp Temp. Group(s) Max. Ext. Surface Temp. Ambient

Temp. Rating °C Code Temp. Rating °C Code

K-G / K-5 / K-10 / K-04 / K-15 GLASS GLOBE & GUARD INCLUDING ANGLE & DOME

MV 100W 260 T2B E, F, G 160 T3C 40°C

MV 175W 300 3 T2 E, F 200 9 T3 9 40°C

MH 250W 350

11

E, F 8 200 T3 40°C

MH 400W — — — — — 40°C

K-L GLASS REFRACTOR AND GUARD 4 12" DIAMETER

MV 100W 230 T2C E, F, G 135 T4 40°C

MV 175W 260 T2B E, F, G 135 T4 40°C

MH 250W 280 T2A E, F, G 135 T4 40°C

MH 400W 325

11

E, F 180 T3A 40°C

K-E ENCLOSED REFRACTOR AND GUARD

MV 100W 230 T2C E, F, G 135 T4 40°C

MV 175W 260 T2B E, F, G 135 T4 40°C

MH 250W 280 T2A E, F, G 135 T4 40°C

MH 400W 300 T2 E, F, G 160 T3C 40°C

K-M ASYMMETRICAL GLASS REFRACTOR AND GUARD

MV 400W 325

11

E, F 180 T3A 40°C

1 Lamp temperature data was obtained in 40°C ambient under normal operating conditions

2 When used with dome or angle reflector temperature is 350°C

3 When used with angle reflector temperature is 325°C

4 Applies to symmetrical and asymmetrical glass refractors

5 Luminaire maximum surface temperature data was obtained under a dust blanket at 40° ambient under normal

operating conditions

6 Pendant, ceiling, and wall mount with angle reflector suitable for Groups E, F, and G, stanchion mount with angle

reflector and all other mounting styles with or without dome reflector suitable for Groups E & F only

7 Stanchion mount with dome reflector unit suitable for Groups E, F, & G, all other mounting styles in this

classification with or without dome or angle reflector suitable for Groups E & F only

8 Pendant, ceiling, and wall mount with angle reflector suitable for Groups E & F, all other mounting styles in this

classification with or without dome or angle reflector suitable for Group E only; temperature is 200/T3

9 175 watt Mercury Vapor fixtures, pendant, ceiling and wall mount with globe only and pendant, ceiling, and wall

mount and angle reflector only, and stanchion mount with dome reflector only; temperature is 180/T3A

10 When used with angle reflector, temperature is 300/T2

11 No T code available for 325°C or 350°C temperature ratings

Hubbell 6


Photometrics

TEST NO: HP-07337

CATALOG NUMBER: KH/KS-10SX-GXX-10

270

360

450

540

540

720

175° 155° 145°


15°

25°

35°

45°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum

FINISH: white paint

CLOSURE: globe with cast aluminum guard

LAMP: 100W HPS

EACH RATED: 9,500 lumens

LINE POWER: 130 watts

135° 125° 175° 145° 125° 115° 105°

115°

105°

95°

85°

75°

65°

55°

300

500

700

900

1100

1300

TEST NO: HP-07341

CATALOG NUMBER: KH/KS-10SX-GXX-14


15°

25°

35°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum with plastic

FINISH: natural

CLOSURE: globe with cast aluminum guard

& dome reflector

LAMP: 100W HPS

EACH RATED: 9,500 lumens

LINE POWER: 130 watts

95°

85°

75°

65°

55°

45°

400

600

800

1000

1200

1400

1600

1800

TEST NO: HP-07333

CATALOG NUMBER: KH/KS-10SX-GXX-15

0 - - - 90 — — — 180

155° 135° 125° 115°

105°


15°

25°

35°

45°

95°

85°

75°

65°

55°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum/steel reflector

FINISH: white paint

CLOSURE: globe w/ wire guard & angle reflector

LAMP: 100W HPS

EACH RATED: 9,500 lumens

LINE POWER: 130 watts

300

500

700

900

1100

TEST NO: HP-07268

CATALOG NUMBER: KH/KS-17HX-GXX-10

175° 155° 145°


15°

25°

35°

135° 125°

45°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum

FINISH: white paint

CLOSURE: globe with cast aluminum guard

LAMP: 175W MH

EACH RATED: 14,000 lumens

LINE POWER: 210 watts

115°

105°

95°

85°

75°

65°

55°

TEST NO: HP-07270

CATALOG NUMBER: KH/KS-17HX-GXX-14

400

600

800

1000

1200

1400

1600

1800

2000

155° 135°125° 115° 105°


15°

25°

35°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum/plastic

FINISH: white paint/natural

CLOSURE: globe/guard with dome reflector

LAMP: 175W MH

EACH RATED: 14,000 lumens

LINE POWER: 210 watts

95°

85°

75°

65°

55°

45°

600

800

1000

1200

1400

1600

1800

2000

2200

2400

2600

TEST NO: HP-07236

CATALOG NUMBER: KH/KS-17HX-GXX-15

0 - - - 90 — — — 180

155° 135° 125° 115°


15°

25°

35°

45°

105°

95°

85°

75°

65°

55°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum/steel reflector

FINISH: white paint

CLOSURE: globe & wireguard with angle reflector

LAMP: 175W MH

EACH RATED: 14,000 lumens

LINE POWER: 210 watts

3000

5000

7000

9000

11000

TEST NO: HP-07398

CATALOG NUMBER: KH/KS-40HX-EXX-00

145°

115°

105°

5° 15° 25° 35°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum, 3002 alloy

FINISH: semi-specular, without bright dip

CLOSURE: clear flat glass

LAMP: MH-400W/U

EACH RATED: 36,000 lumens

LINE POWER: 460 watts

95°

85°

75°

65°

55°

45°

1800

2400

3000

3800

4200

4800

5400

TEST NO: HP-07286

CATALOG NUMBER: KH/KS-40HX-LXX-00

175° 155° 145° 135° 125° 115°


15°

25° 35°

45°

105°

95°

85°

75°

65°

55°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum

FINISH: white paint

CLOSURE: clear prismatic glass refractor type V

LAMP: 400W MH

EACH RATED: 36,000 lumens

LINE POWER: 460 watts

TEST NO: HP-07403

CATALOG NUMBER: KH/KS-40SX-EXX-00

TEST NO: HP-07285

CATALOG NUMBER: KH/KS-40SX-LXX-00

145° 115°

105°

95°

175° 155° 145° 135° 125° 115°

85°

105°

3000

5000

7000

8000

11100

13000


15°

25° 35°

TEST DISTANCE: 36.3'

REFLECTIVE MATERIAL: aluminum, 3002 alloy

FINISH: semi-specular, without bright dip

CLOSURE: clear flat glass

LAMP: C400S51

EACH RATED: 50,000 lumens

LINE POWER: 465 watts

75°

65°

55°

45°

2100

2200

3500

4200

4900

5000

6300


15°

25° 35°

45°

95°

85°

75°

65°

55°

TEST DISTANCE: 41.5'

REFLECTIVE MATERIAL: aluminum

FINISH: white paint

CLOSURE: clear prismatic glass refractor type V

LAMP: 400W HPS

EACH RATED: 50,000 lumens

LINE POWER: 465 watts

Hubbell 7


HUBBELL LIGHTING, INC. WORLDWIDE LOCATIONS

Hubbell Lighting products are manufactured to the highest international standards of quality. ISO 9002 certified facility.

Country-wide certifications are indicated throughout the catalog, including UL and CSA. In addition Hubbell Lighting

products meet the existing NOM requirements for Mexico.

Should you need to verify specific country requirements, please contact Hubbell Lighting, Inc. headquarters in

Christiansburg, Virginia.

UNITED STATES

HUBBELL LIGHTING, INC.

2000 Electric Way

Christiansburg, VA 24073-2500

PHONE: (540) 382-6111

FAX: (540) 382-1526

CANADA

HUBBELL CANADA, INC.

870 Brock Road South

Pickering, Ontario L1W 1Z8

PHONE: (905) 839-1138

FAX: (905) 839-9108

www.hubbell-canada.com

ASIA

HUBBELL S.E. ASIA PTE. LTD.

23 Tagore Lane

#03-16

Tagore 23 Warehouse

Singapore 787601

PHONE: 65-4544772

FAX: 65-4544775

KOREA

HUBBELL INTERNATIONAL, INC.

2nd Floor Jungwon Building

1115-8 Hwagok-6 Dong Kangseo-Ku

Seoul, Korea 157-016

PHONE: 82-2-607-1363

FAX: 82-2-603-7386

MEXICO

HUBBELL DE MEXICO, S.A. DE.CV

Av. Coyoacan No. 1051

Col.Del Valle

03100 Mexico, D.F.

PHONE: (525) 575-2022

FAX: (525) 559-8626

www.hubbell.com.mx

MIDDLE EAST

CHALMIT LIGHTING LTD.

P.O. Box 46100

Abu Dhabi, U.A.E.

PHONE: 9714-2823456

FAX: 9714-2823221

TAIWAN

HUBBELL TAIAN CO., LTD.

12th Floor 66 Sec. 2

Chien Kwo North Road

Taipei, Taiwan

PHONE: (02) 2515-0855

FAX: (02) 2515-0898

(02) 2515-0899

®

®

Entertainment, Inc.

For more information visit our web site: www.hubbelllighting.com

© HUBBELL INCORPORATED Printed in USA FEBRUARY 1998 HAZ