Logic Flaws in NCSC 1982

Logic Flaws in NCSC 1982 Method • Pumps operate anywhere below curve • Pumps can ONLY operate on the curve; artificial/increased head required to reach curve • Head loss in manifold between trenches is ignored • Can be used to control head within a group (zone) • Elevation changes of less than ½ foot between trenches ignored • Actual elevation change is important to an accurate calculation of discharge pressure • Supply/Transmission line connection to drainfield location does not matter • Connection Location is critical to improved method of calculation • Calculated flow rate is presented as actual flow rate • Not an accurate assumption

Travis County Method (~1999) • Rational for Method • Pump selection determines hole spacing by virtue of flow • Pump selection is based on hydraulic characteristics of the piping system • From pump to connection to drainfield at highest trench including all fittings, valves, meters, etc. • The pump is selected based on a point ON the curve. Result: More efficient use of selected pump or the selection of smaller, less expensive pump

Pumps & Panels - Tom Fritts - Texas Onsite Wastewater Association
Wastewater Feasibility Investigation - Texas Onsite Wastewater ...
Advanced Pretreatment/Treatment of Onsite Wastewater ATU and ...
Program_2007:Layout 1.qxd - Texas Onsite Wastewater Association
flow equalization for controling flow through an ossf - Texas Onsite ...
Council - Texas Onsite Wastewater Association
on-site - Texas Onsite Wastewater Association
TOWA Insider - Texas Onsite Wastewater Association
Corporte 2008 - Texas Onsite Wastewater Association
TOWA Insider - Texas Onsite Wastewater Association
TCEQ Normal Template - Texas Onsite Wastewater Association
Inspection of Onsite Wastewater Management Systems
August 9-10-11 in Austin - Texas Onsite Wastewater Association
Florida Onsite Wastewater Association, Inc.
T#:'ffi Hfl Tff i1;:*:il:'#;;,HtHT:f - Texas Onsite Wastewater Association
12-1-10 meeting minutes final.pdf - Texas Onsite Wastewater ...
Onsite Wastewater Treatment Technology and the Preservation of
Volume 13, Issue 1 - Ontario Onsite Wastewater Association
saskatchewan onsite wastewater disposal guide - Regina Qu ...
Onsite Wastewater Treatment Systems Technology Fact ... - Norweco
Buying or Selling a Home with an Onsite Wastewater System
evaluation of gravelless pipe systems for onsite wastewater
Chapter 2: Management of Onsite Wastewater Treatment ... - Norweco
OSTP Pump Selection Design Worksheet - Onsite Sewage ...