Performance Classes

Performance Classes Basic Excellent Perfect Operation Main switch push/turn control for switching on/off resp. (in combination with SET button) setting of parameters Function signal for standby/heating/error/operating mode Visualisation / digital display of all temperature and time settings Visualisation / digital display of all weekday, speed, ramp segment and setup settings _ Menue guidance via 8-digit alphanumerical display _ _ Temperature Electronic microprocessor temperature controller with auto-diagnostic system _ _ Electronic multifunction temperature controller with Fuzzy-Logic and auto-diagnostic system _ One temperature sensor Pt100 Class A in 4-wire circuit with warning indication on failure _ _ Two temperature sensors Pt100 Class A in 4-wire circuit for uninterrupted operation on failure of one Pt100 with warning indication _ Temperature setting range series U/S from +20 °C up to +220 °C from +20 °C up to +250 °C from +20 °C up to +250 °C (U: option up to +300 °C) (U: option up to +300 °C) series I from +20 °C up to +70 °C from +20 °C up to +70 °C from +20 °C up to +70 °C Indication accuracy series U/S 0,5 °C 0,1 °C / 0,5 °C 1) 0,1 °C series I 0,5 °C 0,1 °C 0,1 °C Setting accuracy series U/S 0,5 °C 0,5 °C 0,1 °C / 0,5 °C 1) series I 0,5 °C 0,1 °C 0,1 °C Temperature variation (time) series U/S at 150 °C ≤ ± 0,5 °C ≤ ± 0,25 °C ≤ ± 0,25 °C (to DIN 12880) series I at 37 °C ≤ ± 0,2 °C ≤ ± 0,05 °C ≤ ± 0,05 °C Temperature uniformity in chamber series U/S at 150 °C ≤ ± 2,7 °C ≤ ± 2,2 °C ≤ ± 2,2 °C (to DIN 12880) series I at 37 °C ≤ ± 0,6 °C ≤ ± 0,6 °C ≤ ± 0,6 °C Works calibration certifi cate for one temperature (chamber centre), series U/S: 160 °C; series I: 37 °C _ Monitor Mechanical temperature limiter (TB) for permanent heating switch-off on exceeding the maximum permitted oven temperature by approx. 10 °C Heating switch-off at a fi xed margin of 10 °C (Series U/S) or 3 °C (Series I) above setpoint on failure of electronic heating control Microprocessor temperature monitor acting as overtemperature protection, with Pt100 incorporating fault diagnostics _ _ Microprocessor temperature monitor acting as overtemperature protection and undertemperature alarm, with Pt100 incorporating fault diagnostics _ _ Temperature monitoring band automatically linked to the setpoint (ASF) _ _ Visual / acoustic alarm / _ / _ / Air Circulation Air fl ap for admixture of fresh air, manually adjustable _ Air fl ap for admixture of fresh air, segmentspecifi c adjustable by servomotor _ _ Fan speed adjustable (for Class P segmentspecifi c) 0-100% in 10%-steps (for UF/SF) _ Timerfunctions Real-time/weekly programmer with group function (e.g. Monday-Friday) _ Integral digital switch off-timer (1 min. up to 99 h 59 min.) to switch off heating after preset operating time _ _ Timer with residual running time: max. 4 ramps (each 1 min. up to 999 h) programmable through controller: delayed on, heating up, hold or hold set-temperature-dependent and defi ned cooling down; _ _ programming via PC and free-of-charge software: unlimited number of ramps Timer with residual running time: max. 40 ramps (each 1 min. up to 999 h) for temperature, air fl ap opening and fan speed (for UF/SF) programmable through controller or MEMoryCard XL; _ _ programming via PC and free-of-charge software: unlimited number of ramps Chip card control: entering settings and temperature documentation up to 40 ramps, 1 chip card MEMoryCard XL with 32 kB memory capacity _ _ Sterilisation of incubator-interior by additional chip card (STERICard) with fi xed cycle of 4 h/160 °C (series I) _ _ Repeat function (Loop: 1-99 times / endless) _ Documentation Internal log memory 1024 kB as ring memory for all setpoints, actual values, errors, settings with real-time _ and date; capacity approx. 6 months at 1 min. intervals Parallel printer interface for printing logging fi les, suitable for all PCL3-compatible ink jet printers (USB available via converter, see accessories) _ _ “Celsius“ 2) software for control and documentation of temperature, air fl ap opening (Class P) and fan speed (for UF/SF) _ Setup Calibration (no separate PC required), Temperature: 3-point calibration on controller _ Setting of language for dialogue and display D / UK / E / F / I _ _ Subject to technical modifi cations 1) 0,1 °C up to 99,9 °C; 0,5 °C above 100 °C 2) MEMMERT-Software “Celsius“ has been tested for Windows NT 4, 2000, XP and Vista standard model, basic specifi cation – not available

Special Equipment and Accessories Subject to technical modifi cations 1) special equipment at no extra cost 2) affects temperature distribution. Not available for 300 °C ovens 3) see sketch page 26 resp. 27 4) for special equipment an advance payment Classes Model sizes B E P 100 200 300 400 500 550 600 700 800 Temperature range 300 °C for Universal Ovens (not available for ovens with glass door; alternative solution: Order-No. B1) • • _ A0 A0 A0 A0 A0 A0 A0 A0 Adjustable temperature limiter 1) , protection Class 2, instead of adjustable temperature controller, protection Class 3.1 • • _ A5 A5 A5 A5 A5 A5 A5 A5 Full-sight glass door 2)+3) (triple insulating glass) for series UN/UF (extra) • • _ B0 B0 B0 B0 B0 B0 B0 B0 Stainless steel doors with glass windows (can be used up to 300 °C), pair of doors with triple insulating glass windows window cut-out W x H mm • • _ _ _ _ _ _ B1 350 x 230 Door with lock (safety lock) (standard on size 700 + 800 sterilisers) • • _ B6 B6 B6 B6 B6 B6 B6 B6 Door hinged on the left 4) • • _ B8 B8 B8 B8 B8 _ _ _ Perforated stainless steel shelf, non-tipping • • • E0(x) E0(x) E0(x) E0(x) E0(x) E0(x) E0(x) E0(x) E0(x) Stainless steel tray (non-perforated) 15 mm rim, non-tipping (may affect the temperature distribution) • • • E2(x) E2(x) E2(x) E2(x) E2(x) E2(x) E2(x) E2(x) E2(x) Stainless steel grid 3) • • • E3(x) E3(x) E3(x) E3(x) E3(x) E3(x) E3(x) E3(x) E3(x) Bottom drip tray • • • E8(x) E8(x) E8(x) E8(x) E8(x) E8(x) E8(x) E8(x) E8(x) Entry port 3)+4) (standard position centre/centre or centre top), for introducing connections at the side can be closed by fl ap, 23 mm clear diameter Other port 3)+4) (23 mm diameter) in special positions (please state location) left centre/centre left centre top right centre/centre right centre top left right rear • • _ • • _ Other port 3)+4) (38 mm diameter) at the back (please state location) • • _ F7(x) F7(x) F7(x) F7(x) F7(x) F7(x) F7(x) F7(x) Wall bracket 3) (tubular frame for wall mounting) • • • G0 G0 G0 G0 G0 G0 G0 G0 _ Stacking version 3) for 2 ovens of equal size (bottom oven modifi cation) • • • G3 G3 G3 G3 G3 G3 G3 G3 _ Subframe with height adjustment (height: size 500-600: 622 mm, size 700: 572 mm) 3)+5) • • • _ _ _ _ G5 G5 G5 G5 _ Subframe with castors (height: size 500-600: 622 mm, size 700: 572 mm) 3) • • • _ _ _ _ G6 G6 G6 G6 _ Temperature profi le write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps • _ V3 V3 V3 V3 V3 V3 V3 V3 Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) • _ V4 V4 V4 V4 V4 V4 V4 V4 STERICard (additional or as replacement) for automatic incubator chamber sterilisation cycle (not for sterilising the load!) • _ V9 V9 V9 V9 V9 V9 V9 V9 Oven-linked authorisation card (User-ID-Card) 6) prevents undesired manipulation by unauthorised third parties • _ V1 V1 V1 V1 V1 V1 V1 V1 Computer interface RS485 1) (for networking a max. of 16 ovens) instead of RS232 • _ V2 V2 V2 V2 V2 V2 V2 V2 Interface USB instead of RS232 • • _ W3 W3 W3 W3 W3 W3 W3 W3 Interface USB connection cable for computer • • _ W7 W7 W7 W7 W7 W7 W7 W7 Interface Ethernet instead of RS232 inclusive software “Celsius Ethernet-Edition“ • _ W4 W4 W4 W4 W4 W4 W4 W4 Parallel/USB converter cable with integrated power supply unit to connect HP printers with USB interface to MEMMERT units. Compatible with USB 1.1 and USB 2.0 • _ W1 W1 W1 W1 W1 W1 W1 W1 Documentation package consisting of parallel USB converter cable including PLC3- compatible HP colour inkjet printer with USB interface (HP Deskjet 5940 or successor) • _ W2 W2 W2 W2 W2 W2 W2 W2 for direct connection of printer to Memmert unit Connection cable for computer interface RS232 according to DIN 12 900-1 • • _ V6 V6 V6 V6 V6 V6 V6 V6 Flexible Pt100 4) for positioning in chamber or in load with socket according to NAMUR NE 28 for external temperature recording (load temperature) • • _ H4 H4 H4 H4 H4 H4 H4 H4 Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) • _ H5 H5 H5 H5 H5 H5 H5 H5 Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for combined fault message (e.g. supply failure, sensor fault, fuse) • _ H6 H6 H6 H6 H6 H6 H6 H6 Floating triple contact, for signal generation, controlled by programme segment (using PC), for a total of 3 freely selected functions to be activated • _ H7 H7 H7 H7 H7 H7 H7 H7 (e.g. activation of acoustic and visual signals, exhaust motors, fans, stirrers etc.) Additional Pt100 4) temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, • _ H8(x) H8(x) H8(x) H8(x) H8(x) H8(x) H8(x) H8(x) and can be documented via the “Celsius“ software or on an attached printer. Interior lighting 4) (up to size 600: 15 W, 700/800: 2 x 15 W) • • _ R0 R0 R0 R0 R0 R0 R0 R0 Plug-in tube extension 3) straight (l 88 mm, outer diameter 40 mm, inner diameter 38 mm) for exhaust air ducting (if necessary for connection to extraction system by hose) • • • G7 G7 G7 G7 G7 G7 G7 G7 G7 Plug-in tube extension 3) angled for exhaust air ducting • • • G8 G8 G8 G8 G8 G8 G8 G8 G8 Works calibration certifi cate (U/S) at three temperatures: 100 °C, 160 °C, 220 °C • • _ Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Works calibration certifi cate (I) for models at three temperatures: 37 °C, 52 °C, 70 °C • • _ Z4 Z4 Z4 Z4 Z4 Z4 Z4 Z4 IQ check list with works test data for oven as support for validation by customer • • _ Q1 Q1 Q1 Q1 Q1 Q1 Q1 Q1 OQ check list including one 7) free-selectable temperature distribution survey to DIN 12880: 2007-05 (size 200/300: 9 measuring points, size 400-800: 27 measuring points) • • _ Q2 Q2 Q2 Q2 Q2 Q2 Q2 Q2 with works test data for oven as support for validation by customer Software conforming to FDA “Celsius FDA-Edition“ 8) (extra cost) • _ Q3 Q3 Q3 Q3 Q3 Q3 Q3 Q3 F0 F1 F2 F3 F4(x) F5(x) F6(x) F0 F1 F2 F3 F4(x) F5(x) F6(x) of 20% of the complete price is required 5) height variable; minimum height specifi ed 6) when (re)ordering please specify serial number 7) further temperature distribution surveys at extra cost 8) requires Windows 2000 Professional or XP Professional F0 F1 F2 F3 F4(x) F5(x) F6(x) F0 F1 F2 F3 F4(x) F5(x) F6(x) F0 F1 F2 F3 F4(x) F5(x) F6(x) F0 F1 F2 F3 F4(x) F5(x) F6(x) B1 430 x 230 F0 F1 F2 F3 F4(x) F5(x) F6(x) B1 430 x 230 F0 F1 F2 F3 F4(x) F5(x) F6(x) – not available • accessories available in this perfomance class (x) Please specify quantity required after the order number 25

Memmert Ovens UIS - Levanchimica
3 Year - Fenno Medical Oy
The Experts for Acids, Bases, ORP - Fenno Medical Oy
Redefining Multi-parameter Measurements - Fenno Medical Oy
Memmert Climatic Test Chambers CTC / TTC
Bedside Monitor BSM-9101K - Fenno Medical Oy
Memmert Vacuum Ovens VO - Labequip
MRI with the VNS Therapy System - Fenno Medical Oy
PROCESS SENSORS - Fenno Medical Oy
NIHON KOHDEN Monitoring Solutions - Fenno Medical Oy
CNS-6201 central monitor - Fenno Medical Oy
Multi-parameter Measurement Redefined - Fenno Medical Oy
Ion-selective Measurements - Fenno Medical Oy
Conductivity Meters – The Electrolytical ... - Fenno Medical Oy
Depletion/Respiration BOD Measurements ... - Fenno Medical Oy
pH Value pH Meters - Fenno Medical Oy
Multi-parameter Measurements - Fenno Medical Oy
EIN08909 Lab oven MEMMERT B30r eng - Ebseos Gmbh
Remote Viewer Terminal QP-985P Remote ... - Fenno Medical Oy
Memmert UE BE ULE manual ENG.pdf - Gemini BV