02.12.2014 Views

+ AUTO FLOW VALVES - Zenith Oilfield Technology Ltd

+ AUTO FLOW VALVES - Zenith Oilfield Technology Ltd

+ AUTO FLOW VALVES - Zenith Oilfield Technology Ltd

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

+ <strong>AUTO</strong> <strong>FLOW</strong> <strong>VALVES</strong><br />

INCREASED PRODUCTION & PROTECTION<br />

Typically installed in wells produced by ESP in situations where the well can flow without<br />

assistance, <strong>Zenith</strong> Auto Flow Valves facilitate significant production increases by allowing<br />

continued flow to surface when your pump is switched off.<br />

In addition, the valves enhance pump protection by preventing tubing solids descending<br />

into the pump on shut-down, defending against pump damage.<br />

ZENITH


ZENITH <strong>AUTO</strong> <strong>FLOW</strong> VALVE (AFV)<br />

When the ESP is started in a well with a <strong>Zenith</strong> AFV installed (fig. 2), the AFV pilots its annular<br />

ports to the closed position; pump discharge pressure ensures the valve maintains<br />

this position while producing through the pump. Production flows to the tubing with the<br />

AFV mechanism preventing recirculation.<br />

When the ESP is shut down (fig. 3), the AFV’s annular flow ports automatically open,<br />

preventing backspin and pump damage from sands and debris descending into the pump<br />

— the fluid column drains directly to the annulus.<br />

1. 2. 3. 4.<br />

By rerouting flow around rather than<br />

through the non-operational ESP, thereby<br />

eliminating the associated restriction and<br />

resulting damage to the pump, significant<br />

improvements in production can be<br />

realised. <strong>Zenith</strong> Auto Flow Valves also<br />

immediately divert solids to the annulus<br />

when the ESP is switched off (fig. 4),<br />

preventing the back-flow of sand clogging<br />

the ESP stages.<br />

The <strong>Zenith</strong> Auto Flow<br />

Valve released an additional<br />

$140,000 per week from the<br />

well with the further benefit<br />

of preventing ESP failure<br />

through solids management<br />

on pump shut-down.


AFV BENEFITS<br />

Facilitates significant production increases by allowing continued flow to surface by bypassing the restriction of the ESP when pump is switched off<br />

Increases ESP runlife:<br />

» Prevention of damage to the stationary pump by reducing scale, wear and debris build-up by channelling flow through the annular ports<br />

» Further damage avoidance on shut-down by avoiding tubing solids descending into the pump<br />

» Prevents ESP back-spin or breaking motor shafts at start up<br />

Interventionless operation as no control lines or wireline intervention required during normal operation<br />

AFV FEATURES<br />

Accommodates ESP cable bypass facility<br />

AFV OPTIONS<br />

Valve sizing options to suit the tubing size and flow<br />

Can be supplied for deployment using any type of wireline or coil tubing lock system<br />

ZENITH


ZENITH WIRELINE-RETRIEVABLE <strong>AUTO</strong> <strong>FLOW</strong> VALVE (W-AFV)<br />

When a well is no longer free flowing the<br />

<strong>Zenith</strong> Wireline-Retrievable Auto Flow Valve<br />

(W-AFV) can be retrieved from the well with<br />

slickline.<br />

The <strong>Zenith</strong> Wireline-Retrievable AFV is typically installed on a standard lock in a ported<br />

nipple (fig. 1) or sliding sleeve situated above an ESP. It brings all the advantages of the<br />

standard AFV but can be retrieved from the well with slickline and replaced with an isolation<br />

sleeve (fig. 2). Running or pulling the valve with standard wireline tools addresses any<br />

concerns relating to additional equipment in the well bore.<br />

A derivative of the W-AFV can be included in the <strong>Zenith</strong> Total Protection Bypass system.<br />

1. 2.<br />

The W-AFV can be redressed and reinstalled in a<br />

new well significantly increasing the return on your<br />

investment.


W-AFV BENEFITS<br />

Facilitates significant production increases by allowing continued flow to surface by bypassing the restriction of the ESP when pump is switched off<br />

Increases ESP runlife:<br />

» Prevention of damage to the stationary pump by reducing scale, wear and debris build-up by channelling flow through the annular ports<br />

» Further damage avoidance on shut-down by avoiding tubing solids descending into the pump<br />

» Prevents ESP back-spin or breaking motor shafts at start up<br />

Interventionless operation as no control lines or wireline intervention required during normal operation<br />

Value enhanced through opportunity to reinstall in subsequent wells<br />

W-AFV FEATURES<br />

Accommodates ESP cable bypass facility<br />

Retrieved using standard slickline procedures<br />

» Supplied with isolation sleeve which may be run at any time in place of the valve if well conditions change<br />

W-AFV OPTIONS<br />

Valve sizing options to suit the tubing size and flow<br />

Can be installed in either a ported sub or sliding sleeve<br />

Can be supplied for deployment using any type of wireline or coil tubing lock system<br />

ZENITH


ZKG-0605-005_10 — April 2008 — © <strong>Zenith</strong> — zenithoilfield.com<br />

<strong>Zenith</strong> <strong>Oilfield</strong> <strong>Technology</strong> patents pending & protected worldwide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!