+ <strong>AUTO</strong> <strong>FLOW</strong> <strong>VALVES</strong><br />
INCREASED PRODUCTION & PROTECTION<br />
Typically installed in wells produced by ESP in situations where the well can flow without<br />
assistance, <strong>Zenith</strong> Auto Flow Valves facilitate significant production increases by allowing<br />
continued flow to surface when your pump is switched off.<br />
In addition, the valves enhance pump protection by preventing tubing solids descending<br />
into the pump on shut-down, defending against pump damage.<br />
ZENITH
ZENITH <strong>AUTO</strong> <strong>FLOW</strong> VALVE (AFV)<br />
When the ESP is started in a well with a <strong>Zenith</strong> AFV installed (fig. 2), the AFV pilots its annular<br />
ports to the closed position; pump discharge pressure ensures the valve maintains<br />
this position while producing through the pump. Production flows to the tubing with the<br />
AFV mechanism preventing recirculation.<br />
When the ESP is shut down (fig. 3), the AFV’s annular flow ports automatically open,<br />
preventing backspin and pump damage from sands and debris descending into the pump<br />
— the fluid column drains directly to the annulus.<br />
1. 2. 3. 4.<br />
By rerouting flow around rather than<br />
through the non-operational ESP, thereby<br />
eliminating the associated restriction and<br />
resulting damage to the pump, significant<br />
improvements in production can be<br />
realised. <strong>Zenith</strong> Auto Flow Valves also<br />
immediately divert solids to the annulus<br />
when the ESP is switched off (fig. 4),<br />
preventing the back-flow of sand clogging<br />
the ESP stages.<br />
The <strong>Zenith</strong> Auto Flow<br />
Valve released an additional<br />
$140,000 per week from the<br />
well with the further benefit<br />
of preventing ESP failure<br />
through solids management<br />
on pump shut-down.
AFV BENEFITS<br />
Facilitates significant production increases by allowing continued flow to surface by bypassing the restriction of the ESP when pump is switched off<br />
Increases ESP runlife:<br />
» Prevention of damage to the stationary pump by reducing scale, wear and debris build-up by channelling flow through the annular ports<br />
» Further damage avoidance on shut-down by avoiding tubing solids descending into the pump<br />
» Prevents ESP back-spin or breaking motor shafts at start up<br />
Interventionless operation as no control lines or wireline intervention required during normal operation<br />
AFV FEATURES<br />
Accommodates ESP cable bypass facility<br />
AFV OPTIONS<br />
Valve sizing options to suit the tubing size and flow<br />
Can be supplied for deployment using any type of wireline or coil tubing lock system<br />
ZENITH
ZENITH WIRELINE-RETRIEVABLE <strong>AUTO</strong> <strong>FLOW</strong> VALVE (W-AFV)<br />
When a well is no longer free flowing the<br />
<strong>Zenith</strong> Wireline-Retrievable Auto Flow Valve<br />
(W-AFV) can be retrieved from the well with<br />
slickline.<br />
The <strong>Zenith</strong> Wireline-Retrievable AFV is typically installed on a standard lock in a ported<br />
nipple (fig. 1) or sliding sleeve situated above an ESP. It brings all the advantages of the<br />
standard AFV but can be retrieved from the well with slickline and replaced with an isolation<br />
sleeve (fig. 2). Running or pulling the valve with standard wireline tools addresses any<br />
concerns relating to additional equipment in the well bore.<br />
A derivative of the W-AFV can be included in the <strong>Zenith</strong> Total Protection Bypass system.<br />
1. 2.<br />
The W-AFV can be redressed and reinstalled in a<br />
new well significantly increasing the return on your<br />
investment.
W-AFV BENEFITS<br />
Facilitates significant production increases by allowing continued flow to surface by bypassing the restriction of the ESP when pump is switched off<br />
Increases ESP runlife:<br />
» Prevention of damage to the stationary pump by reducing scale, wear and debris build-up by channelling flow through the annular ports<br />
» Further damage avoidance on shut-down by avoiding tubing solids descending into the pump<br />
» Prevents ESP back-spin or breaking motor shafts at start up<br />
Interventionless operation as no control lines or wireline intervention required during normal operation<br />
Value enhanced through opportunity to reinstall in subsequent wells<br />
W-AFV FEATURES<br />
Accommodates ESP cable bypass facility<br />
Retrieved using standard slickline procedures<br />
» Supplied with isolation sleeve which may be run at any time in place of the valve if well conditions change<br />
W-AFV OPTIONS<br />
Valve sizing options to suit the tubing size and flow<br />
Can be installed in either a ported sub or sliding sleeve<br />
Can be supplied for deployment using any type of wireline or coil tubing lock system<br />
ZENITH
ZKG-0605-005_10 — April 2008 — © <strong>Zenith</strong> — zenithoilfield.com<br />
<strong>Zenith</strong> <strong>Oilfield</strong> <strong>Technology</strong> patents pending & protected worldwide