Assembly instructions

for KLARO UV hygienisation stage

We provide clear water

No mechanics

in the wastewater

No pumps

in the wastewater

No electrical parts

in the wastewater


No mechanics

in the wastewater

No pumps

in the wastewater

No electrical parts

in the wastewater


Assembly instructions KLARO UV hygienisation stage

Assembly instructions for KLARO

UV hygienisation stage

Certificates: Z-55.3-214, Z-55.3-215, Z-55.3-369

Version: 13/02/2013

KLARO GmbH 3


Assembly instructions KLARO UV hygienisation stage

Table of contents

Page

1. About this instruction manual ......................................................................................5

1.1. Original language of the document ............................................................................5

1.2. Copyright...................................................................................................................5

1.3. Completeness ...........................................................................................................5

1.4. Liability ......................................................................................................................5

2. General safety notes .....................................................................................................6

3. Product description.......................................................................................................6

3.1. Application.................................................................................................................6

3.2. Scope of delivery.......................................................................................................7

4. Installation .....................................................................................................................8

4.1. Assembly and electrical connection of the UV radiator ..............................................8

4.2. Internal assembly of the switching device..................................................................9

4.3. External assembly of the switching device...............................................................10

4.4. Cable installation .....................................................................................................11

4.5. Electrical connection of the UV reactor ....................................................................11

4.6. Inserting the UV module in the manhole ..................................................................13

4.7. Commissioning........................................................................................................13

5. Technical data .............................................................................................................13

4

KLARO GmbH


Assembly instructions KLARO UV hygienisation stage

IMPORTANT:

• These assembly instructions contain information about the installation of

electrical components and must thus be read before the assembly of the UV

hygienisation stage!

• All safety notes must be observed!

• Keep the assembly instructions for further use.

1. About this instruction manual

These assembly instructions are part of the product and must be read before the

assembly of the UV module.

1.1. Original language of the document

The original language of this document is German.

1.2. Copyright

© KLARO GmbH

Spitzwegstrasse 63

D-95447 Bayreuth

Technical support: +49 (0) 921-16279330

Email: info@klaro.eu

Internet: www.klaro.eu

All rights expressly reserved. Duplication or distribution to third parties in any form is

only allowed with the prior consent of KLARO GmbH.

1.3. Completeness

These instructions have been complied with due diligence. Any liability of the

manufacturer due to incorrect or missing information as well as linguistic deficiencies or

printing errors in the documentation is excluded. In case you discover any

incompleteness and/or errors, please do not hesitate to contact us at the above address.

When preparing the instruction, we tried to ensure that the facts detailed herein are in

utmost compliance with the corresponding system. Nevertheless, all technical data,

dimensions and illustrations in these instructions are non-binding. Possible claims on the

correct functioning of the system cannot be derived from the instructions.

Within the scope of improvement and progress, we reserve the right to make

amendments to the system without making according changes in these instructions. No

obligation can be derived hereof for the installation of changed technology in already

completed and delivered systems.

This document is regularly updated.

1.4. Liability

The manufacturer cannot be held liable in case of:

• non-compliance with or inadequate use of the information made in these instructions,

• the use of spare parts or parts in the system which have not been approved by

KLARO GmbH,

• incorrect assembly of the wastewater treatment plant,

• the removal, manipulation or bridging of protective devices,

KLARO GmbH 5


Assembly instructions KLARO UV hygienisation stage

• not approved changes to the system,

• incorrect maintenance and change of spare parts.

Unauthorised changes to the system or the operation of the system beyond the

specifications given by the manufacturer will result in the termination of all warranty

claims.

2. General safety notes

ELECTROSHOCK!

Caution! Dangerous electrical voltage.

Non-compliance may result in serious physical damage.

EYE PROTECTION MUST BE WORN!

Description: Please wear safety glasses to protect your

eyes from UVC radiation.

CAUTION!

UVC radiation is harmful to the eyes and skin! UV lamps

may only be used in the radiation chamber if suitable

protective covers have been installed. Under no

circumstances should persons be exposed to UVC

radiation.

The UV module must always be disconnected from the circuit before:

• any repair work is performed.

• any cleaning work is carried out.

• the UV radiator is replaced.

Do not operate the UV radiator outside the UV reactor.

PLEASE NOTE: We strongly recommend having any maintenance work carried out by

qualified experts.

3. Product description

3.1. Application

The UV hygienisation stage is used to disinfect domestic wastewater that has already

been treated by means of the SBR method. The UV module without pump can only be

used as integrated hygienisation stage. The UV module with pump can either be

installed downstream to the biological treatment stage in a separate pit or directly

integrated into the SBR reactor of the plant.

6

KLARO GmbH


Assembly instructions KLARO UV hygienisation stage

3.2. Scope of delivery

The UV hygienisation stage (without control cabinet and retrofit kit) for the internal

assembly consists of the following components.

Item no.: Quantity Description

1 UNIT

1 UNIT

UV reactor with pump* on retaining

plate

UV reactor with siphon on retaining

plate

909006

UV module

S50

with pump

909007

UV module

S50

without pump

909006

UV module

S80

with pump

● ○ ●

○ ● ○

5 m Radiator cable 4x 0.5 mm² ○ ○ ●

20 m Radiator cable 4x 0.5 mm² ● ● ○

5 m

20 m

901356 1 UNIT

Earthing cable H07V-K 1x 2.5 mm²

gn/ye

Earthing cable H07V-K 1x 2.5 mm²

gn/ye

○ ○ ●

● ● ○

1 UNIT Switching unit** 180 x 254 x 111 mm ● ○ ●

1 UNIT Switching unit**180 x 180 x 111 mm ○ ● ○

VA retaining bar with an overall

length of 996mm

● ● ●

980359 3 UNITS Heavy-duty anchor B8-4/60 A4 ● ● ●

980639 2 UNITS Pipe clamp PE DN40 ● ● ●

980156 6 UNITS

Nail dowel M6X40 V2A countersunk

head

● ● ●

980076 4 UNITS Cable tie 280/4.5 mm bl. ● ● ●

When assembling the hygienisation stage in an A cabinet, the following components

must be added.

Item no.: Quantity Description

981462 1 UNIT

Retaining plate for UV

switching device

909006

UV module S50

with pump

909007

UV module

S50

without pump

909008

UV module S80

with pump

● ● ●

980551 8 UNITS Screws M5x12 ● ● ●

980011 8 UNITS Hexagonal nut M5 ● ● ●

980612 4 UNITS Drill screw 4.2 x 19 ● ● ●

980003 4 UNITS Washer D 6.4 ● ● ●

○ Not included in the scope of delivery● Included in the scope of delivery

* The pump is delivered together with a connection cable YSLY-JB 3x 1 mm² with a length of 18 m.

** The switching unit is delivered together with a connection cable YSLY-JB 3x 1 mm² with a length

of 2.5 m.

KLARO GmbH 7


Assembly instructions KLARO UV hygienisation stage

4. Installation

4.1. Assembly and electrical connection of the UV radiator

For transport safety reasons, the UV radiator is safely packaged and attached to the

outside of the UV reactor. Prior to commission, the UV radiator must be inserted in the

UV reactor and connected afterwards:

• For this, the UV reactor must be placed flat on the floor outside the container.

• The UV radiator must be removed from its packaging and cleaned by using a

clean cloth. Caution! Please do not touch the quartz glass of the UV radiator

with your bare, unprotected hands.

• Connect the 4-pin sleeve to the UV radiator. Carefully insert the radiator in the

quartz protection tube until it is fully recessed.

• Slightly loosen the cap nut of the M12 fitting. Afterwards, screw in the VA fitting

hand-tight. Then, fasten the M12 fitting and the cap nut hand-tight. Position the

VA protective cap in place and fasten the M16 fitting hand-tight.

• Connect the earthing cable to the UV reactor.

M16 fitting

VA protective cap

M12 fitting

VA fitting

4-pin sleeve

UV radiator

Earthing cable

M5 cap nut

VA head end

Earthing connection

8

KLARO GmbH


Assembly instructions KLARO UV hygienisation stage

• The free end of the connection cable should be properly coiled up and hung up

at an appropriate location in the upper area of the manhole. If required, use the

supplied PE DN40 pipe clamps. By using another clamp, the cables between the

empty conduit and the first clamp can be secured. For this, the clamp can be

mounted to the cover of the tank. ATTENTION: Do not pull the entire cable

through the empty conduit to the control cabinet! In the manhole, cable of a

sufficient length must be available as reserve in such a manner that the

UV module can be pulled out for maintenance purposes!

Figure 1: Connection cable coiled up for maintenance purposes (in the concrete tank)

4.2. Internal assembly of the switching device

The switching device has a connection cable with a length of 2.5 m; for the internal

assembly, care must be taken that the switching unit is assembled next to the control

cabinet.

Figure 2: Assembly of the switching device inside the

building

KLARO GmbH 9


Assembly instructions KLARO UV hygienisation stage

4.3. External assembly of the switching device

An external assembly of the switching device is only possible in connection with an

A cabinet 1, 2 or B cabinets. For the B cabinets, the switching device is fastened to the

installation plate. The assembly in the A cabinet 1 and 2 is carried out in the base of the

control cabinet (see below).

Figure 3: Vertical assembly in the base

Figure 4: Horizontal assembly in the base

For the vertical assembly, the retaining plate

is fastened by means of two drill screws to

the cut-out.

For the horizontal assembly, the retaining

plate and the cut-out of the base should be

pre-drilled by using a 5.5 mm drill. For

fastening, two screws, nuts and flat washers

each are required.

Approx. 3 cm

10

KLARO GmbH


Assembly instructions KLARO UV hygienisation stage

The brackets of the switching unit should be

enlarged, for instance, by using a

screwdriver. Thus, the screws can be

inserted more easily.

The switching device must be fastened to

the retaining plate by using 4 screws and 4

nuts.

4.4. Cable installation

After the connection of the UV reactor, the connection cables must be pulled through the

empty conduit to the control cabinet and connected in the switching device (4.5

Electrical connection of the UV reactor).

Important! In order to ensure smooth operation, the excess cable at the switching

device must be cut off. Do not coil up the cables. The entire length of the radiator cable

must not exceed the following values: for S50 20 m and for S80 5 m! Larger cable

lengths may only be used upon consultation with the engineering department!

4.5. Electrical connection of the UV reactor

In order establish a safe connection, the individual wires should be stripped to a length

of 9 to 11 mm. The connection is carried out conveniently from the front by using a small

slot screwdriver.

Terminal connections of the UV module S50 without pump

Unit Colour Terminal no. Cable type Remarks

white 1

Electrode 1

brown 2

UV radiator

4x 0.5 mm²

green 3

Electrode 2

yellow 4

Earthing of the UV

5 H07V-K

green/yellow

reactor

1x 2.5 mm²

KLARO GmbH 11


Assembly instructions KLARO UV hygienisation stage

Terminal connections of the UV module S50 with pump

Unit Colour Terminal

Wastewater

pump

UV radiator

Earthing of the

UV reactor

Cable type

no.

black 1 3

YSLY-JB

black 2 4

3x 1 mm²

green/yellow 5

white 6

brown 7

green 8

4x 0.5 mm²

yellow 9

green/yellow

10 H07V-K

1x 2.5 mm²

Remarks

Electrode 1

Electrode 2

Terminal connections of the UV module S80 with pump

Unit Colour Terminal

no.

Cable type

black 1 3

Wastewater

black 2 4

pump

green/yellow 5

YSLY-JB 3x 1 mm²

Earthing of the

5 H07V-K 1x 2.5 mm²

green/yellow

UV reactor

Ballast no.

yellow 1

UV radiator green 2

brown 3

4x 0.5 mm²

white 4

Remarks

Electrode 1

Electrode 2

Terminal block of the UV module S50

without pump

Terminal block of the UV module S50 with

pump

12

KLARO GmbH


Assembly instructions KLARO UV hygienisation stage

Connection of the radiator cable to the

ballast of the UV module S80

Terminal block of the UV module S80 with

pump

4.6. Inserting the UV module in the manhole

• Fill the UV module with fresh water.

o For the UV module with pump, pour in the water on the outlet side by

using a can.

o For the UV module without pump, pour in the water in the siphon on the

inlet side by using a can until flows out of the outlet.

• Insert the complete UV module in the manhole in the provided rail system. Make

sure that the outlet of the UV module can safely drain in the outlet of the tank

and/or in the sampling unit!

4.7. Commissioning

• The UV module is automatically controlled by the KLplus control mechanism.

The switch-on times are factory-preset. Check under the menu item “setup

report“ whether a time has been set under the sub-item “switch-on period UVtime“

(“xx Min“ UV module has not been activated - consultation with specialist

company or manufacturer]).

• The UV module can be tested in the “manual mode”. For this, use the arrow keys

to select “manual UV-unit: off. By pressing the numbers “1“ for “on“ and “0“ for

“off“ the UV module can be switched on and off.

5. Technical data

• Stainless steel reactor with centrally arranged high-performance UV radiator (Hglow-pressure

radiator)

• Removable radiator protection tube

• Radiation dose at the end of the operating life = 400 joule/m² for UV transmission 1

cm = 60%

• Wavelength of the UVC light = 254 nm

• Type of protection of the UV reactor IP 68 at 3 bar, control unit (ballast in the

switching unit) IP66

KLARO GmbH 13


Assembly instructions KLARO UV hygienisation stage

UV module type ABOX S50 ABOX S80

Length of the UV module [mm] 1000 1250

Width of the UV module [mm] 260 330

Connections inch 1 1

Maximum flow rate [l/min] 18 43

Type UV lamp / radiator HG 50/4 W HG 80/4 W

Radiation output [Watt] 50 80

Radiant flux 254 nm [Watt] 15 25

Operating voltage of the switching

230 V/50 Hz

device

Power rating [Watt] 75 95

Operating voltage of the pump

230 V/50 Hz

Power rating [Watt] 80

Subject to technical changes!

14

KLARO GmbH


The KLARO principle

Maximum operating reliability!

No mechanics, pumps or

electrical parts in the wastewater!

All components are permanently connected to the filtering tank. All transportation

processes are performed by the air-lift pump. All electrical parts are located securely

outside the tank in the switch cabinet.

Our benefits

••

TÜV-tested switch cabinets (EPP,

indoor switch cabinet, outdoor

switch cabinet)

••

Almost all possible approvals

••

Extremely short delivery times

thanks to optimised production

••

Legal threshold values undercut

by up to 90%

••

98% treatment performance in 6

hours

••

Certified underload detection

••

Fully-biological mode of operation

••

Quality products, with extremely

high customer satisfaction levels

••

Minimal power consumption

••

All transportation processes performed

by air-lift pump

••

Treat water and introduce it back

into the natural cycle

••

Only one tank required for systems

of up to 20 PE (Personnel

Equivalent)

••

Suitable for retrofitting to practically

any tank shape

••

Retrofitting possible in single,

twin, triple and multi-chamber pits

••

Installation possible in any type of

tank, from plastic to fibreglass to

concrete


KLARO GmbH

Spitzwegstraße 63

95447 Bayreuth

Telephone: +49 (0) 921 16279-0

Fax: +49 (0) 921 16279-100

E-Mail: info@klaro.eu

More information at

www.klaro.eu