<strong>HDPE</strong> pipe dimensions (cont.)<br />

4427<br />

PE 63 Nominal working Pressure HDS<br />

PE 80 Nominal working Pressure HDS<br />

PE 100 Nominal working Pressure HDS<br />

Standard diameter ratio<br />

Nominal<br />

size mm<br />

Mean outside<br />

diameter<br />

5MPa<br />

6.3MPa<br />

8MPa<br />

Maximum out<br />

of roundness<br />

(Class ) PN 10<br />

(Class ) PN 12.5<br />

(Class ) PN 16<br />

Wall<br />

thickness t<br />

SDR 11<br />

<strong>Pipe</strong> ID<br />

and mass<br />

(Class ) PN 12.5<br />

(Class ) PN 16<br />

(Class ) PN 20<br />

Wall<br />

thickness t<br />

SDR 9 SDR 7.4<br />

<strong>Pipe</strong> ID<br />

and mass<br />

(Class ) PN 16<br />

(Class ) PN 20<br />

(Class ) PN 25<br />

Wall<br />

thickness t<br />

<strong>Pipe</strong> ID<br />

and mass<br />

Min Max Ovality Min Max ID Kg/m Min Max ID Kg/m Min Max ID Kg/m<br />

16 16 16.3 1.20<br />

20 20 20.3 1.20<br />

25 25 25.3 1.20<br />

32 32 32.3 1.30<br />

40 40 40.4 1.40<br />

50 50 50.5 1.40<br />

63 63 63.6 1.50<br />

75 75 75.7 1.60<br />

90 90 90.9 1.80<br />

110 110 111.0 2.20<br />

125 125 126.2 2.50<br />

140 140 141.3 2.80<br />

160 160 161.5 3.20<br />

180 180 181.7 3.60<br />

200 200 201.8 4.00<br />

225 225 227.1 4.50<br />

250 250 252.3 5.00<br />

280 280 282.6 9.80<br />

315 315 317.9 11.10<br />

355 355 358.2 12.50<br />

400 400 403.6 14.00<br />

450 450 454.1 15.60<br />

500 500 504.5 17.50<br />

560 560 565.0 19.60<br />

630 630 635.7 22.10<br />

1.6 1.9 13 0.08<br />

1.8 2.1 16 0.11<br />

2.3 2.7 20 0.17<br />

2.9 3.4 26 0.27<br />

3.6 4.3 32 0.43<br />

4.5 5.3 40 0.67<br />

5.7 6.7 51 1.06<br />

6.8 7.8 61 1.50<br />

8.2 9.4 73 2.16<br />

10.0 11.5 89 3.22<br />

11.4 13.1 101 4.16<br />

12.7 14.6 113 5.21<br />

14.5 16.3 130 6.72<br />

16.4 18.3 146 8.51<br />

18.2 20.4 162 10.50<br />

20.5 22.8 183 13.27<br />

22.7 25.3 203 16.38<br />

25.5 28.4 227 20.54<br />

28.6 31.9 256 26.00<br />

32.3 36.0 288 33.01<br />

36.4 40.5 325 41.91<br />

40.9 45.4 366 52.94<br />

45.5 50.5 406 65.36<br />

50.9 56.5 455 81.97<br />

57.3 63.6 512 103.75<br />

1.8 2.1 12 0.08<br />

2.2 2.6 15 0.13<br />

2.8 3.3 19 0.20<br />

3.6 4.2 24 0.33<br />

4.4 5.2 31 0.51<br />

5.6 6.5 38 0.80<br />

7.0 8.2 48 1.27<br />

8.3 9.6 57 1.78<br />

10.0 11.5 69 2.57<br />

12.2 14.1 84 3.84<br />

13.9 16.0 96 4.96<br />

15.6 17.9 107 6.22<br />

17.8 19.9 123 8.02<br />

20.0 22.4 138 10.16<br />

22.2 24.9 154 12.53<br />

25.0 27.9 173 15.83<br />

27.8 31.0 192 19.55<br />

31.1 34.7 216 24.52<br />

35.0 39.0 242 31.03<br />

39.4 44.0 273 39.41<br />

44.4 49.6 308 50.03<br />

50.0 55.5 347 63.19<br />

55.6 61.7 385 78.01<br />

2.2 2.5 11 0.10<br />

2.7 3.2 14 0.15<br />

3.4 4.0 18 0.24<br />

4.3 5.1 23 0.39<br />

5.4 6.3 28 0.60<br />

6.8 7.9 36 0.94<br />

8.5 10.0 45 1.50<br />

10.1 11.7 54 2.11<br />

12.2 14.0 64 3.04<br />

14.9 17.1 79 4.53<br />

16.9 19.4 89 5.86<br />

18.9 21.8 100 7.34<br />

21.6 24.2 115 9.48<br />

24.3 27.2 129 12.00<br />

27.0 30.3 144 14.81<br />

30.4 33.9 162 18.71<br />

33.8 37.7 180 23.10<br />

37.8 42.2 201 28.97<br />

42.6 47.5 226 36.67<br />

48.0 53.5 255 46.56<br />

54.1 60.3 287 59.11<br />

60.8 67.5 324 74.67<br />

Temperature/pressure derating<br />

The rated working pressure of an <strong>HDPE</strong> pipe is determined<br />

at 20 o C. Where the operating temperature of the fluid in<br />

the pipe exceeds 20 o C, the pressure rating of the pipe<br />

has to be de-rated in order to maintain the designed safety<br />

factors of the pipe.<br />

<strong>HDPE</strong> pipe is not recommended in applications where<br />

the fluid temperature exceeds 50 o C.<br />

Temperature of fluid<br />

in the pipe<br />

Derating factor apply<br />

to maximum working<br />

pressure<br />

0 - 20 1,0<br />

20 - 25 0,9<br />

25 - 30 0,8<br />

30 - 35 0,7<br />

35 - 40 0,6<br />

40 - 45 0,5<br />

45 - 50 0,4<br />

SA’s leading producer of <strong>HDPE</strong> pipe<br />