2010 Short Form Catalog - Thermo-Kinetics

thermo.kinetics.com

2010 Short Form Catalog - Thermo-Kinetics

2010

Short

Form

Catalog

Digital Indicators & Controllers

predig.com/videos

C

US

Simplified information where and how you want it.

P

flow

lEVEl

P

PRESSURE

TEMPERATURE

Precision Digital corPoration Since 1974

www.predig.com


2010

Short

Form

Catalog

www.predig.com

table oF ContentS

Digital Panel Meters

Process Meters ................................... 4, 6, 7, 8, 13, 14

Rate/Totalizers ....................................................5, 7, 8

Batch Controllers ....................................................... 8

Loop-Powered Meters .............................................7, 8

Temperature Meters.................................4, 6, 8, 13, 14

High Voltage Meter ..................................................... 7

Modbus Serial Input Meter ......................................... 7

Digital Field and Panel Mount Meters (Fluidwell) ....... 8

Large Display Meters ....................................................12

Multi-Channel Process Controller ................................ 9

Wireless Multi-Channel Process Controller ................ 9

Hazardous Area Meters (Loop and/or Battery-Powered)

Process Meter ..................................7, 8, 10, 11, 12, 15

Rate/Totalizer .............................................. 7, 8, 12, 15

Temperature Controllers ..............................................13

Temperature Transmitters ............................................. 3

Annunciators .................................................................13

Scanners ........................................................................13

Digital Pressure Gauges ..............................................12

Precision Calibrator ......................................................11

Enclosures .....................................................................16

Disclaimer

The information contained in this document is subject to change without notice.

Precision Digital Corporation makes no representations or warranties with respect

to the contents hereof, and specifically disclaims any implied warranties of

merchantability or fitness for a particular purpose.

©2010 Precision Digital Corporation. All rights reserved.

2 FLOW • LEVEL • PRESSURE • TEMPERATURE See Data Sheets at www.predig.com for Complete Details


2010

Short

Form

Catalog

www.predig.com

exSenSe t hart Smart temperature tranSmitterS

®

• Smart temperature transmitters with HART protocol

• Universal input: RTD, TC, resistance & mV inputs

• Easy to program with PC or HART communicator

• Order configured at the factory ready to install

• Explosion-proof model with 330° rotatable backlit LCD

• Display PV, input type, engineering units & bargraph

• Explosion-proof model PD312 with integral Pt100 RTD

• Low-cost model PD301, PC programmable

• 2-wire scalable 4-20 mA output

• Galvanic isolation prevents ground loops

• Wide voltage range: 10.5 to 45 VDC

• Operating temperature: -40 to 75°C

• Automatic cold junction compensation for TC inputs

• Protection heads & thermowells available

• FM, CSA, ATEX, IECEx explosion-proof enclosures

Smooth

Die Cast

aluminum

ExS ense

series

Model PD312 Hart ®

Model PD310 Hart ®

Model PD306 Hart ®

Model PD303

OVERViEW quick select guide applications

Model PD301 Model PD302 Hart ®

Approvals presently apply to explosion-proof enclosure only.

Complete product approvals expected soon, contact factory for details.

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details

3


the moSt powerFul line

Process

PR

VU

Level

Pressure

Temperature

SerieS 6-digit dual-line

NEMA 4X Front • 0.6" Display • Function Keys

Process

PD6000 ProVu Process Meter

• 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V inputs

• Isolated 24 VDC @ 200 mA transmitter power supply

• Isolated 24 VDC @ 40 mA 4-20 mA output power supply

• Math functions for round horizontal tanks

• 32-point linearization with free software

• Multi-pump alternation control

• New dual display of level in various units of measure

PD7000 ProVu temperature Meter

• J, K, T, E, R, S, B, N, C thermocouples

• 100 or 1000 Ω platinum, 10 Ω copper,120 Ω nickel RTDs

• 1.0° or 0.1° resolution

• Averages up to 10 RTD sensors

Large

0.6" Digits

Temperature

provu iS not juSt a pretty FaCe

UV Resistant

Sunlight Readable

Front Panel

NEMA 4X Rated

Actual Size

Sunlight

Readable

Rugged Front

Dual-Line

6-Digit

Display

Overflow

Indication

User Configurable

Display

Total

PV, Max (Peak),

Min (Valley)

Rate

Programmable

Function Keys

NEMA 4X

Alarm

Status Indicators


oF 1/8 din panel meterS

Flow Rate indicator

Flow Totalizer

Rate & Total

Total & Grand Total

meterS & Flow rate/totalizerS

• Sunlight Readable Display • 2 or 4 Relays + isolated 4-20 mA Output Options

Flow

PD6200 ProVu analog Input

Flow rate/totalizer

• 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V inputs

• Isolated 24 VDC @ 200 mA transmitter power supply

• Open channel flow with programmable exponent

• Square root extraction

• 32-point linearization

PD6300 ProVu Pulse Input

Flow rate/totalizer

• Pulse, open collector, NPN, PNP, TTL, switch contact,

sine wave (coil), square wave inputs

• 5, 10 or 24 VDC flowmeter power supply

• Gate function for rate display of slow pulse rates

• K-Factor, internal scaling, or external calibration

• 4-20 mA output option converts the pulse input to an

isolated 4-20 mA output

Flow

Common ProVu Flow rate/totalizer Features

• Dual-Line display shows rate & total at same time • Any relay assigned to rate or total

• Total, grand total, or non-resettable grand total

• 4-20 mA output assigned to rate or total

• 9-digit totalizer with total overflow feature

• Sampling relay

Add any of these

optional modules

to any ProVu at

any time.

expanSion

moduleS


4-Relay (form A)

• 8 Digital I/O (up to 2)

• RS-232 Serial Communications*

• RS-485 Serial Communications*

* Free Modbus protocol with purchase

of serial communications module.

dual-line diSplay

makeS all the diFFerenCe

Liters

%

Competition

Total

what do I do next

Level

Rate

PR VU

SERIES

two Lines are Better than One!

• Two Lines = More Information + Easier Setup

• Even with TWO LiNES, the ProVu’s Main Display is Still BiGGER


2010

Short

Form

Catalog

www.predig.com

applications quick select guide

OVERViEW

6

1/8 din proCeSS & temperature panel meterS

FLOW • LEVEL • PRESSURE • TEMPERATURE

NEMA 4X iP65 Front • Shallow Depth Case • AC or DC Power

TRIDENT

PD765 trident & trident X2

Process & temperature Meters

• 4-20 mA, ± 10 V, TC & RTD inputs

• 4-digit display

• Trident: 0.56"; Trident X2: 1.20"

• Sunlight readable display

• Two relays option with alternation & time delay

• 4-20 mA analog output option

• Transmitter power option

• Serial communication options

®

• Modbus RTU or proprietary ASCII protocol

®

• Free MeterView

software

the trident X2 Has the LargeSt Display of any 1/8 DIN Meter

TRiDENT 0.56" DiSPLAy

Actual Size

1/8 din low-CoSt proCeSS & temperature panel meterS

NEMA 4X iP65 Front • Shallow Depth Case • AC or DC Power

PD603 Sabre P Low-Cost

OeM Process Meter

• 4-20 mA, ± 10 V inputs

• 4-digit display

• Easy front panel programming

• Transmitter power option

Sabre Series

PD743 Sabre t Low-Cost

OeM temperature Meter

• J, K, T, E thermocouple & 100 Ω Pt RTD

• 4-digit display

• Easy front panel programming

• Max/min display

See Data Sheets at www.predig.com for Complete Details

TRiDENT X2 1.20" DiSPLAy


2010

Short

Form

Catalog

www.predig.com

1/8 din Shallow depth modbuS & dC panel meter

PD865 Snooper

Modbus Serial Input Meter

®

• RS-485 Modbus

RTU input

• 6-digit display

• Master, slave, or snooper mode

• Two relays standard

• 4-20 mA analog output option

• Up to four pump alternation control

R

NEMA 4X iP65 Front • Shallow Depth Case • AC or DC Power

PD644 Javelin D

High-Voltage DC Meter

• 0-300 VDC input

• 4-digit display

• 4-20 mA analog output

• Two relays option

®

• Modbus RTU

1/8 din loop-powered panel meterS & rate/totalizerS

5 Digits

0.6" High

Trend Arrow

Bargraph

PD683 & PD688

Panel Meters

PD688 Only

NEMA 4X iP65 Front • Shallow Depth Case • Loop-Powered

Loop Leader ®

-

• 4-20 mA input

• 2 V drop (5.7 V with backlight)

• 5-digit LCD, 0.6" high

• Loop-powered backlight

• Custom engineering units

• 20-segment bargraph display

• NEMA 4X, IP65 front

• Linear, square root,

and programmable exponent

• Alarm or pulse output option

• Operates from -40 to 65°C

+

Series

PD684 & PD689

rate/totalizers

R

PD689 Only

Engineering

Notation

Custom

Engineering

Units

Backlight

Standard

OVERViEW quick select guide applications

FLOW • LEVEL • PRESSURE • TEMPERATURE

Actual Size

See Data Sheets at www.predig.com for Complete Details

7


2010

Short

Form

Catalog

www.predig.com

high perFormanCe Fluidwell F-SerieS

applications quick select guide

OVERViEW

Trend

indication

Operating

temperature

-30/-40 to 80°C

Large

LCD with

backlight

option

Status

indicator

rate/totalizers

Flow Computers

Displayed

function

• Analog or pulse input

• Multi-point linearization

• 7-digit flow rate display

• 7-digit total display

• 11-digit non-resettable total

• Bi-directional measurement

• High & low alarms

• Analog & pulse outputs

• Analog or pulse input

• Temperature compensation

for liquids

• Temperature & pressure

compensation for gas

• Ratio calculation & monitoring

• Fuel consumption calculation

• 11-digit non-resettable total

Flow Controllers

• Analog or pulse input

• Analog control output

• Two alarm outputs for low & high flow

• Bumpless transfer to Auto mode

• Green LED backlight

• Serial Modbus communications

• Safety input mode to place

controller into predefined position

Clear 0.7" or

1" digits

Rugged tactile

response keys

Measurement

units for TOTAL

NEMA

4X

aluminum

or plastic

field enclosure

Engineering

units

0.3" alphanumeric

display

• 4-20 mA, 0-10 V, pulse, or RTD inputs

• AC, DC, loop, or battery power

• Rugged NEMA 4X enclosures

• Field & panel mount enclosures

• Intrinsically safe or explosion-proof

• Operates from -30/-40 to 80°C

• Serial Modbus ®

communications

• Backlighting

Flow • Temperature • Level • Pressure

Batch Controllers

• Analog or pulse input

• 1 or 2 stage batch control

• Start, stop, & pause buttons

• Overrun correction

• Count up or count down

• Flow rate, preset value,

& total display

• 11-digit non-resettable total

temperature, Level

& Pressure Indicators

• Analog or RTD input

• Multi-point linearization

• Displays volume, height & %

• Dual pressure inputs

• High & low alarms

• Analog output

general Purpose Indicators

• Loop-powered indicators

• On-screen engineering units

• Pie graph indicator

• Adjustable backlight intensity

• 5½ digits, 1" high display

C US

Hazardous

Location

8

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details


2010

Short

Form

Catalog

www.predig.com

ConSolidator ® multi-Channel ControllerS

advantages

• Easy-to-read backlit LCD

• Readable in direct sunlight

• Bargraphs & numeric screens

• Easy to set up & program

• RS-232 Modbus ®

RTU

• Direct Modbus PV inputs

• Power from AC or DC

• Wall or panel mount

• 32-point linearization

• Free programming & data logging software

ConsoliDator ®

ConsoliDator 4 Features

• Four 4-20 mA inputs

• Four 4-20 mA outputs

ConsoliDator 8 Features

• Eight 4-20 mA inputs

• Two 4-20 mA outputs

Common Features

• Four pulse inputs

• Four digital inputs

• Nine 10 A relays

ConSolidator ®

wireleSS SyStemS

• Allows remote monitoring & alarming

• Reduces installation costs versus hard-wired

• Minimizes manual reading costs

• Monitors up to eight points

• Communicates up to 1200 feet indoors,

5 miles outdoors

• Monitors & data logs at remote office location

• Makes multiple-use of data

OVERViEW quick select guide applications

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details

9


2010

Short

Form

Catalog

www.predig.com

exploSion-prooF proCeSS meterS & rate/totalizerS

applications quick select guide

OVERViEW

RT

Common Features

• 5-digit, 0.7" upper display

• 7 characters, 0.4" lower display

• SafeTouch through-glass button programming

• Explosion-proof, IP68, NEMA 4X enclosure

• Flanges for wall or pipe mounting

• Operates from -40 to 75°C

ProteX PD6800 Process Meter &

ProteX-rt PD6820 analog Input rate/totalizer

• 4-20 mA input loop-powered

• 2.8 V drop (5.8 V with backlight)

• Linear, square root, or programmable exponent

• Loop-powered & DC-powered backlight option

ProteX-rt PD6830 Pulse Input rate/totalizer

• Battery, DC, or output loop powered

• Battery, DC, and output loop powered backlight option

ProteX-Lite PD663 explosion-Proof

Loop-Powered Process Meter

• 4-20 mA input

• 1.7 V drop (4.9 V with backlight)

• 3½+ digits LCD, 0.6" high

• Loop-powered backlight option

• Easy four-button programming

• Programmable noise filter

• Max/min display

• Password protection

• HART protocol transparent

• Operates from -40 to 75°C

TM

PD6830 Coming soon. Contact factory for details.

Smooth

Die Cast

aluminum

TM

Lite

TM

Approvals presently apply to

explosion-proof enclosure

only. Complete product

approvals expected soon,

contact factory for details.

Smooth

Die Cast

aluminum

Approvals presently apply to explosion-proof enclosure only.

Complete product approvals expected soon, contact factory for details.

ProteX-One PD6870 explosion-Proof

Loop-Powered Process Meter

• 4-20 mA input

• 1 V drop (4 V with backlight)

• 3½ digits LCD, 1" high

• Loop-powered backlight option

• Explosion-proof, IP68, NEMA 4X enclosure

• Flanges for wall or pipe mounting

• Easy calibration and installation

• Operates from -40 to 75°C

TM

One

Smooth

Die Cast

aluminum

10

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details


2010

Short

Form

Catalog

www.predig.com

hatChet loop-powered proCeSS meterS

PD685 general Purpose

preCiSion

Calibrator

NIST Traceable

Certificate with

Calibration Data

Included!

PD9500 Calibrator


Initial (6-months) accuracy to 0.0025% of rdg. (V)


1-year accuracy to 0.005% of rdg. (V)

loop-powered nema 4x meterS

• Source TC (13), RTD (9), V, mA, & pressure (read only)

• Custom RTD and SPRT profiles

• Nine setpoints for each output range and type

• RS-232, and IEEE-488 remote control

PD662 NeMa 4X general Purpose

• 4-20 mA input

• 1.7 V drop (4.9 V with backlight)

• 3½+ digits LCD, 0.6" high

• Loop-powered backlight option

• Easy four-button programming

• Programmable noise filter

• Max/min display

• Password protection

• HART protocol transparent

• Operates from -40 to 75°C

(-55 to 85°C with heater option)

• 4-20 mA input

• 1 V drop

• 3½ digits LCD, 1.0" high

• Operates from -40 to 80°C

PD686 Only

R

• Direct keyboard entry


24 VDC loop power

PD686 Hazardous area

• Compatible with fluke Met/Cal

®

software

• Isolated measurement channel

®

• Selectable 250 ohm HART resistor

Coming Soon

• Beryllium-copper binding posts reduce thermal EMFs

OVERViEW quick select guide applications

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details

11


2010

Short

Form

Catalog

www.predig.com

large diSplay meterS & totalizerS

applications quick select guide

OVERViEW

PD656 explosion-Proof

0.8" High LEDs

2.3" High LEDs

• 4-20 mA, 1-5 V, 0-5 V, 0-10 V inputs

• 4½ digits & extra zero display for rate

• 6-digit display for total

• Programmable exponent for weirs & flumes

• Pump alternation control

• Two 24 VDC transmitter power supplies

• 200 mA transmitter power supply option

• 2 or 4 relays & 4-20 mA output options

• 115, 230 VAC, or 24 VDC power

• Operates from -20 to 65°C

These multi-function digital pressure gauges are a great

solution that will save you time, money, and space. They

are loaded with features such as large numeric and

bargraph backlit LCD, 4-20 mA output, and relay options.

Battery power is standard; loop-power and 12-36 VDC

power are optional.

• General purpose, industrial, & test models

• Direct pressure input

• Battery, loop, or DC powered

PD650 NeMa 4X

• FM approved & CSA certified models

PD650

digital preSSure gaugeS

PD655 NeMa 4X

1.0" High LEDs

PD655 PD656

(Actual Digit Size)

R

12

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details


2010

Short

Form

Catalog

www.predig.com

vigilante ® ii alarm annunCiatorS

PD154

4-Point

PD138 Minimux ® II

PD158

8-Point

PD154 & PD158 Vigilante ® II

• All common ISA sequences including first-out

• Switch, transistor, and logic level inputs

• Free custom message labels

• AC or DC power

• NEMA 4X, IP65 front

• Built-in 85 dB horn

• 2 SPDT relays for alarm activated devices

• Silence, acknowledge, and reset functions

• LED self-test with power up

• Shallow depth 1/8 DIN case

minimux ® ii temperature & proCeSS SCanner

Thermocouple, RTD, process, AC & DC inputs

• 8 inputs (double-pole reed relays)

• Unlimited number of units per system

• Adjustable dwell time for each channel

• Independent alarm input for each channel

• User initiated full self-test

nova SerieS proCeSS & temperature ControllerS

From simple temperature indication and on/off control to

auto-tuning PID control applications, the Nova Series Process

and Temperature Controllers handle a variety of applications

with ease and a high degree of accuracy.

Key Features

• Universal process & temperature input

• Relay & analog outputs standard

• High accuracy display & control

PDS178 & PDS178X2 watchdog

Scanning & alarm Systems

The Watchdog is a kit that includes a PD765-6R2-00

or PD765-6X2-00 Trident and PD138-3 Minimux II in

a PDA2821 NEMA 4X enclosure. The Watchdog is a

Temperature Scanning and Alarm System ready to wire

into your application. Get all this at a significant savings

versus buying separately.

OVERViEW quick select guide applications

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details

13


2010

Short

Form

Catalog

www.predig.com

1/8 din digital panel meterS QuiCk SeleCt guide

Overview

Process & Temperature Process Meters Temperature Meters

qUiCK SELECT GUiDE

applications

Model

PD765

Trident

PD765

Trident X2

PD603

Sabre P

PD6000

ProVu

PD743

Sabre T

PD7000

ProVu

Type Process & Temp Process & Temp Process Process Temperature

Temperature

input

Field Selectable

Display

Lines

Digit Height

Process/Rate

Total

Toggle/Dual R+T

4-20 mA, 0-20 mA

1-5 V, 0-5 V

-10 to 10 V

J, K, T, E TC

100 Ω Pt RTD

4-digit

1 line

0.56" (14.2 mm)

9,999

N/A

N/A

4-20 mA, 0-20 mA

1-5 V, 0-5 V

-10 to 10 V

J, K, T, E TC

100 Ω Pt RTD

4-digit

1 line

1.20" (30.5 mm)

9,999

N/A

N/A

4-20 mA

1-5 V

0-5 V

0-10 V

4-digit

1 line

0.56" (14.2 mm)

9,999

N/A

N/A

4-20 mA

0-20 mA

1-5 V

0-5 V

-10 to 10 V

6-digit

2 lines

0.60", 0.46"

999,999

N/A

N/A

J, K, T, E TC

100 Ω Pt RTD

4-digit

1 line

0.56" (14.2 mm)

9,999

N/A

N/A

J, K, T, E, R, S, B, N, C TC

100 or 1000 Ω Pt RTD

10 Ω Cu RTD

120 Ω Ni RTD

6-digit

2 lines

0.60", 0.46"

9,999.9

N/A

N/A

Display intensity Adjustable Adjustable Fixed Adjustable Fixed Adjustable

Programming

Method

Root Function

Linearization

Max/Min Display

Transmitter Power

Front Panel

Meter Copy

PC with MeterView

Front Panel

Meter Copy

PC with MeterView

Front Panel

Square Root Square Root N/A

Toggle,10 sec,

momentary, continuous

Dual 24 VDC @ 200

mA & 40 mA (option)

Toggle,10 sec,

momentary, continuous

Dual 24 VDC @ 200

mA & 40 mA (option)

Toggle,10 sec,

momentary, continuous

24 VDC @ 200 mA

(option)

Relays/Outputs 2 Form C 3 A 2 Form C 3 A N/A

Relay Operation

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

Pump alternation

On & off time delay

Fail-Safe or normal

Front panel ACK or PC

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

Pump alternation

On & off time delay

Fail-Safe or normal

Front panel ACK or PC

4-20 mA Output Process Variable Process Variable N/A

N/A

Front Panel

Meter Copy

PC with MeterView ®

Pro

Square Root

Round Horizontal Tank

Programmable Exp.

Math Function

32-point

Dual-Line or Toggle

24 VDC @ 200 mA or

5/10 VDC @ 50 mA

(standard), 24 VDC

@ 40 mA (option)

2 or 4 Form C 3 A

+ 4 external Form A

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

Pump alternation

On & off time delay

Fail-Safe or normal

Front panel ACK or I/O

Sampling

Output interlock using

digital input

PV, Max/Min,

Setpoint, Manual

Front Panel

N/A

Toggle,10 sec,

momentary, continuous

N/A

N/A

N/A

N/A

Front Panel

Meter Copy

PC with MeterView ®

Pro

N/A

Dual-Line or Toggle

24 VDC @ 200 mA or

5/10 VDC @ 50 mA

(standard), 24 VDC

@ 40 mA (option)

2 or 4 Form C 3 A

+ 4 external Form A

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

On & off time delay

Fail-Safe or normal

Front panel ACK or I/O

Output interlock using

digital input

PV, Max/Min,

Setpoint, Manual

Serial Comm. RS-232, RS-422/485 RS-232, RS-422/485 N/A RS-232, RS-422/485 N/A RS-232, RS-422/485

Expandable N/A N/A N/A Relays, I/O, Comm. N/A Relays, I/O, Comm.

Programmable i/O None None None 8 Inputs / 8 Outputs None 8 Inputs / 8 Outputs

Protocol

Software

Power Options

Operating

Temperature

Proprietary ASCII or

Modbus RTU

MeterView ® ,

LabVIEW

Universal 85-265 VAC

or 12-36 VDC

Proprietary ASCII or

Modbus RTU

MeterView ® ,

LabVIEW

Universal 85-265 VAC

or 12-36 VDC

N/A Modbus RTU N/A Modbus RTU

N/A MeterView ® Pro

N/A MeterView ®

Pro

Universal 85-265 VAC

or 12-36 VDC

Universal 85-265 VAC

or 12/24 VDC

Universal 85-265 VAC

or 12-36 VDC

Universal 85-265 VAC

or 12/24 VDC

0 to 65°C 0 to 65°C 0 to 65°C -40 to 65°C 0 to 65°C -20 to 65°C

Approvals CE, UL & C-UL CE, UL & C-UL CE, UL & C-UL CE, UL & C-UL CE, UL & C-UL CE, UL & C-UL

Standard Warranty 3 years parts & labor 3 years parts & labor 1 year parts & labor 3 years parts & labor 1 year parts & labor 3 years parts & labor

14

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details


2010

Short

Form

Catalog

www.predig.com

1/8 din digital panel meterS QuiCk SeleCt guide

Flow Rate/Totalizers Strain Gauge High-Voltage Serial Data Loop-Powered

PD6200

ProVu

PD6300

ProVu

PD691

PD644

Javelin D

PD865

Snooper

PD683-PD688

Loop Leader

PD684-PD689

Loop Leader

Rate/Totalizers Rate/Totalizers Strain Gauge High-Voltage DC Serial Data indicators Rate/Totalizers

4-20 mA

0-20 mA

1-5 V

0-5 V

-10 to 10 V

6-digit

2 lines

0.60", 0.46"

999,999

999,999,999 †

Dual

Pulse or square wave

Open collector

or switch

0-5 V, 0-12 V

@ 30 kHz

6-digit

2 lines

0.60", 0.46"

999,999

999,999,999 †

Dual

±15 mV

±100 mV

0-30 mV

0-200 mV

4½ digits

1 line

0.56" (14.2 mm)

199,99(0)

N/A

N/A

0 to 300 VDC Modbus RTU 4-20 mA 4-20 mA

4-digit

1 line

0.56" (14.2 mm)

9,999

N/A

N/A

6-digit

1 line

0.56" (14.2 mm)

999,999

N/A

N/A

5-digit

1 line

0.60" (15.2 mm)

99,999

N/A

N/A

5-digit

1 line

0.60" (15.2 mm)

99,999

99,999,999 †

Toggle

Adjustable Adjustable Fixed Adjustable Adjustable N/A N/A

Front Panel

Meter Copy

PC with MeterView ®

Pro

Square Root

Round Horizontal Tank

Programmable Exp.

Math Function

32-point

Front Panel

Meter Copy

PC with MeterView ®

Pro

Front Panel

Front Panel

Meter Copy

PC with Modbus

32-point N/A N/A

Dual-Line or Toggle Dual-Line or Toggle N/A

24 VDC @ 200 mA or

5/10 VDC @ 50 mA

(standard), 24 VDC

@ 40 mA (option)

2 or 4 Form C 3 A

+ 4 external Form A

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

Pump alternation

On & off time delay

Fail-Safe or normal

Front panel ACK or I/O

Sampling

Output interlock using

digital input

Rate, Total, Grand Total

Max, Min, Setpoint, Manual

24 VDC @ 200 mA or

5/10 VDC @ 50 mA

(standard), 24 VDC

@ 40 mA (option)

2 or 4 Form C 3 A

+ 4 external Form A

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

Pump alternation

On & off time delay

Fail-Safe or normal

Front panel ACK or I/O

Sampling

Output interlock using

digital input

Rate, Total, Max, Min,

Setpoint, Manual

24 VDC @ 20 mA

5 or 10 VDC @ 50 mA

Toggle,10 sec,

momentary, continuous

24 VDC @ 200 mA

(option)

Front Panel

PC with Modbus

Square Root

Programmable Exp.

16-point

Toggle,10 sec,

momentary, continuous

24 VDC @ 200 mA

(option)

Front Panel

N/A

Toggle,10 sec,

momentary, continuous

N/A

Front Panel

Square Root

Programmable Exp.

Totalizer Conversion

Toggle,10 sec,

momentary, continuous

2 or 4 Form C 2 A 2 Form C 3 A 2 Form A, 2 Form C Open Collector Open Collector

High or low alarm

100% deadband

Auto & manual reset

Fail-Safe or normal

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

Pump alternation

On & off time delay

Fail-Safe or normal

Front panel ACK or PC

High or low alarm

100% deadband

Auto & manual reset

Latch or non-latch

Pump alternation

On & off time delay

Fail-Safe or normal

Front panel ACK or PC

Alarm or pulse output

N/A

Alarm or pulse output

Process Variable Process Variable Process Variable N/A N/A

RS-232, RS-422/485 RS-232, RS-422/485 N/A RS-485 RS-485 N/A N/A

Relays, I/O, Comm. Relays, I/O, Comm. N/A N/A N/A N/A N/A

8 Inputs / 8 Outputs 8 Inputs / 8 Outputs N/A N/A N/A N/A N/A

Modbus RTU Modbus RTU N/A

MeterView ® Pro

MeterView ® Pro

N/A

Universal 85-265 VAC

or 12/24 VDC

Universal 85-265 VAC

or 12/24 VDC

115 or 230 VAC

Proprietary ASCII or

Modbus RTU

MeterView ®

(data logging only)

Universal 85-265 VAC

or 12-36 VDC

Modbus RTU N/A N/A

Any Modbus RTU

compatible

Universal 85-265 VAC

or 12-36 VDC

N/A

Loop-Power

N/A

Loop-Power

-40 to 65°C -40 to 65°C 0 to 60°C 0 to 65°C 0 to 65°C -30 to 65°C -20 to 65°C

Overview qUiCK SELECT GUiDE applications

CE, UL & C-UL CE, UL & C-UL UL & C-UL UL & C-UL UL & C-UL FM, CSA, ATEX (PD688)

FM, CSA, ATEX (PD689)

3 years parts & labor 3 years parts & labor 2 years parts & labor 3 years parts & labor 3 years parts & labor 3 years parts & labor 3 years parts & labor

† With overflow

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details

15


2010

Short

Form

Catalog

www.predig.com

enCloSureS QuiCk SeleCt guide

Overview

PDa2322 PDa2407 PDa2446 PDa2501

Need Help Selecting an Enclosure

www.predig.com/esu

PDa2601 PDa2703 PDa2801 PDa2901

qUiCK SELECT GUiDE

applications

Thermoplastic Polyester NEMA 4X

Mount Externally

Plastic NEMA 4X

Mount internally

Cast-Aluminum

PDA2300 - Plastic Economical

Model

# of

Meters

Type

A B C D E

PDA2301* 1 •

PDA2302* 2 • • • •

PDA2303* 3 • • • •

PDA2304* 4 • • • •

PDA2305* 5 • • • •

PDA2306* 6 • • • •

PDA2307 7 • • • •

PDA2308 8 • • • •

PDA2309 9 • • • •

PDA2310 10 • • • •

PDA2312 2 • • • •

PDA2322 2 • • • ◙ •

Model

• Available ◙ 1 Required

PDA2440 - Explosion-Proof

Model

PDA2400 - Plastic

# of

Meters

# of

Meters

Type

A B C D E

PDA2444 1 • • • • •

PDA2445 2 •

Type

A B C D E

PDA2407 1 • • • • •

PDA2408 2 •

PDA2409 3 •

PDA2410 4 •

PDA2411 2 • • • • •

PDA2412 3 •

PDA2414 2 • • • ◙ •

PDA2415 4 •

• Available ◙ 1 Required

PDA2446 2 • • • •

PDA2448 1 Fluidwell

Thermoplastic Polyester NEMA 4X

Mount Externally

Stainless Steel NEMA 4X

Mount Externally

Meter Types

Type

A

B

C

D

E

PDA2500 - Plastic Rugged

Model

Meters

# of

Meters

PD690, PD691, PD692, PD693, PD750, PD751, and PD752

PD542, PD543, and PD562

PD603, PD644, PD683, PD684, PD688, PD689, PD743, PD765, and PD865

PD138, PD154, and PD158

Type

A B C D E

PDA2501* 1 • •

PDA2502* 2 • •

PDA2503* 3 • •

PDA2504* 4 • • • •

PDA2505* 5 • • • •

PDA2506* 6 • • • •

PDA2507 7 • • • •

PDA2508 8 • • • •

PDA2509 9 • • • •

PDA2510 10 • • • •

PDA2512 2 • • • •

PDA2522 2 • ◙

• Available ◙ 1 Required

PDA2600 - Stainless Steel

Model

# of

Meters

Type

A B C D E

PDA2601* 1 •

PDA2602* 2 •

PDA2603* 3 •

PDA2604* 4 • • • •

PDA2605* 5 • • • •

PDA2606* 6 • • • •

PDA2622 2 • ◙

• Available ◙ 1 Required

PD6000, PD6200, PD6300, and PD7000

Steel NEMA 4

Mount Externally

Plastic NEMA 4X

Low-Cost

Plastic

NEMA 4X

Model

PDA2700 - Steel

# of

Meters

Type

A B C D E

PDA2701* 1 •

PDA2702* 2 •

PDA2703* 3 •

PDA2704* 4 • • • •

PDA2704-1 1 • • • •

PDA2704-2 2 • • • •

PDA2705* 5 • • • •

PDA2706* 6 • • • •

PDA2713 4 • • ◙ •

PDA2722 2 • ◙

• Available ◙ 1 Required

PDA2800 - Plastic Low-Cost

Model

# of

Meters

Type

A B C D E

PDA2801 1 •

PDA2811 1 • • • •

PDA2812 2 • • • •

PDA2821 2 • • ◙ •

• Available ◙ 1 Required

ConsoliDator Enclosures

Model

# of

Meters

Meter Types

Size

PDA2901 1 ConsoliDator Small

PDA2904 1 ConsoliDator Large

16

* Vertical panel cutouts available for Type D meters. To order add -V at the end of part number (e.g. PDA2501-V).

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details


2010

Short

Form

Catalog

www.predig.com

appliCation photoS & diagramS

Tank Level Monitoring with PD650

PD765 Tridents Measuring Temperature

Overview

quick select guide

Convenient Display for Overhead Transmitters

Visual Flow indication with ConsoliDator

APPLiCATiONS

PD6000 ProVu Displaying Level

PD765 Tridents in a Steel Mill

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details

17


2010

Short

Form

Catalog

www.predig.com

appliCation photoS & diagramS

APPLiCATiONS

quick select guide

Overview

PD6000 Monitoring Oil Level

PD656 Explosion-Proof Level indicator

PD688 Loop Leader in Div 2 Panel

Replacing Lights, Horns, Buttons, Labels,

Relays & Logic with Vigilante ® ii

18

PD9500 Calibrator under Computer Control

FLOW • LEVEL • PRESSURE • TEMPERATURE

NOVA Controllers & NOVA Software

See Data Sheets at www.predig.com for Complete Details


MENU

F1

F2

F3

2010

Short

Form

Catalog

www.predig.com

appliCation photoS & diagramS

Two Tridents in a PDA2502 Enclosure

Alarm Monitoring with ConsoliDator

Overview quick select guide

Lube Oil Flow Monitoring with Fluidwell

Bearing Temperature Monitoring on a Ferry

Open Channel Flow

Round Horizontal Tank

4-20 mA Out

Relay 2

Relay 1

123 56 34 2 1

4-20 mA signal

4-20 mA Output

from Level Transmitter

Level

Transmitter

Hi

Alarm

Lo

Alarm

+

Linearized

4-20 mA output

from ProVu


Loop-Powered

Remote

Indicator

(Volume)

4-20 mA Loop powered by

the ProVu meter

APPLiCATiONS

Programmable root function for weirs and flumes.

This function automatically calculates the volume in

a round horizontal tank with flat ends.

FLOW • LEVEL • PRESSURE • TEMPERATURE

See Data Sheets at www.predig.com for Complete Details

19


MENU

F1

F2

F3

MENU

F1

F2

F3

MENU

F1

F2

F3

MENU

F1

F2

F3

MENU

F1

F2

F3

batCh Control & pump alternation

1

Batch Control with Fluidwell

Start button is pressed

Pump Alternation Control with ProVu Series

1

PROG

ENTER

START

STOP

ON

Hi

Alarm

Lo

Alarm

OFF

2

Barrel is filling

2

Relay #4 turns the main pump on at 6000 gallons

and turns it off at 1000 gallons.

PROG

ENTER

START

STOP

OFF

Hi

Alarm

Lo

Alarm

3

Operator stops batch to check something

With the Pump Alternation feature activated, the next

time the level reaches 6000 gallons, relay #3 transfers

and starts the backup pump.

3

4

PROG

START

STOP

ENTER

Operator starts batch again

Hi

Alarm

Lo

Alarm

If the backup pump is not able to keep up, and the

level reaches 7000 gallons, relay #4 transfers and

starts the main pump as well.

PROG

ENTER

START

STOP

4

5

Batch reaches preset and filling stops

Hi

Alarm

Lo

Alarm

Relay #2 trips the High Level Alarm at

7500 gallons and resets at 6900 gallons.

PROG

ENTER

START

STOP

5

6

Alternative accumulated total displayed

PROG

ENTER

START

STOP

Relay #1 trips the Low Level Alarm at 495 gallons and

resets at 750 gallons.

www.predig.com

precision digital corporation

89 October Hill Road • Holliston MA 01746 USA

Tel. (800) 343-1001 • Fax (508) 655-8990

LMDSFC_D 02/10