CHECKOUT AND ADJUSTMENT 7<br />
Remove all tubes from sockets and set all controls to maximum resistance. Timing adjustments<br />
should be made with a stopwatch (1/10 second accuracy) or a centisecond electric timer.<br />
Do not connect cable to dummy for steps 1 to 13.<br />
Procedure Correct Indication Possible Trouble<br />
1. Remove the AC plug and Pl.<br />
Close SI. Connect ohmmeter<br />
across Pt's socket.<br />
Approximately 60 ohms.<br />
AC short. T1 's primary open.<br />
2. Replace P1. Connect ohmmeter 10,000 ohms. B+ short. Cl leaky or pofrom<br />
pin 5 of VI to chassis.<br />
larity incorrect.<br />
3. Plug in VI. Set SI to ON. V1 should glow. P1 should light. R1 open. SRI, VI or T1 defective.<br />
4. Plug in V2. Rotate R3 to minimum<br />
resistance.<br />
V2 should glow and go out regularly.<br />
Adjust R3 for 10- second intervals<br />
between flashes.<br />
5. Step on mat -switch 53. RY1 should energize. NIT should<br />
light. V1 should glow steadily.<br />
6. Plug in V3.<br />
7. Depress then release 52.<br />
8. Set R9 to full clockwise. Depress<br />
then release 52.<br />
9. Depress 52 and release after<br />
test.<br />
10. Adjust R6. Depress 52 and<br />
release after test.<br />
Filament should glow.<br />
Meter should indicate about half<br />
scale.<br />
M1 should deflect full scale (to the<br />
right).<br />
When RYI closes; meter should drop<br />
fast to 0.<br />
R6 sets meter drop -off time to<br />
exactly 2 seconds.<br />
R2, R3, R4, R5, C3, C4 or<br />
V2 defective.<br />
Mat- switch defective,<br />
coil defective.<br />
V3 defective.<br />
RY1's<br />
V3, R8, R9 defective. .11 con -<br />
tacts open.<br />
Value of R8 incorrect. Read -<br />
just R9.<br />
R6 open. C5 defective.<br />
C5 or R6 incorrect value.<br />
11. Plug in V4. Filament should glow. V4 defective.<br />
12. Depress 52 and wait.<br />
(Release after test.)<br />
When RY1 closes, NL1 should light<br />
and MI should drop. About 4<br />
seconds later, RY2 should close and<br />
NL2 should light.<br />
13. Adjust R11 (robot timer). Adjust R11 so that NL2 lights 1.3<br />
seconds after NL1 for average competition;<br />
less time for fast guns.<br />
V4, R13, P3, R11, R10, C6,<br />
C7, RY2's coil SR3 or RY1 con -<br />
tacts defective.<br />
R11 defective .<br />
Connect robot to the control console. Step on the mat -switch. The following should happen: After a short<br />
wait (up to 10 seconds) th= dummy's eyes should light, followed 1.3 seconds later by gun's raising. Meter<br />
should drop to zero in 2 seconds. NL1 and NL2 should react at same time as the eyes and gun respectively.<br />
Continue tests;<br />
14. Plug in V5 and be sure chest<br />
plate is not touching back contacts.<br />
15. Push chest plate against contarts.<br />
V5 should not glow. RY3 should<br />
not pull in.<br />
RY3 should close. PL2 should light.<br />
(No effect on meter.)<br />
16. Depress 52. RY3 should de- energize. P2 should<br />
go out.<br />
Finally, check each of these sequences:<br />
V5 defective. C9 open .<br />
VS, R14, SR4, C8, RY3's coil,<br />
P4, R15, C9 defective.<br />
52 defective.<br />
17. Step on mat -switch. Allow eyes to light, meter to drop, arm to come up. Push chest plate. The eyes<br />
should go out, arm should remain raised. The meter should indicate more than 1.3 seconds and P2<br />
should light.<br />
18. Step off mat -switch and depress 52. Step on mat -switch and repeat step 17, except push chest plate after<br />
eyes light but before lrm comes up. The eyes should go out but the arm stays down. The meter should<br />
indicate less than 1.3 seconds and P2 should light.<br />
19. Step off the mat- switch and depress 52. Step on mat -switch and let circuits go through cycle without<br />
touching chest plate. The eyes mould light and stay lit, arm should come up, meter drops all the way,<br />
P2 does not light.<br />
If the tests up to No. 16 are successful but incorrect thereafter, the trouble is either incorrect relay contact<br />
wiring or defective relay contacts. As a final test, check il 's wiring by plugging another O -1 ma meter in<br />
.11. The panel meter should be inoperative while the second meter takes over.<br />