31.12.2014 Views

PRODUCTION RANGE - bresson

PRODUCTION RANGE - bresson

PRODUCTION RANGE - bresson

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>PRODUCTION</strong> <strong>RANGE</strong><br />

BRESSON a.s.<br />

Brojova 2113/16, 326 00 Plzeň<br />

Mailing address:<br />

Prague office:<br />

Ovčárecká 312, 280 02 Kolín V V Jámě 1/699, 110 00 Praha 1<br />

Czech republic<br />

Czech republic<br />

Phone:+420 321 740 444 Phone: + 420 266 313 778<br />

Fax: +420 321 725 268 Fax: + 420 266 312 699<br />

E-mail: <strong>bresson</strong>@<strong>bresson</strong>.cz<br />

www.<strong>bresson</strong>.cz


BRESSON a. s. Production Range 2002<br />

BRESSON a. s. as the upholder of ČKD DUKLA and Strojírny Kolín [Enginering Works] manufactures<br />

and supplies a wide range of the equipment required by power engineering, industries, thermal power<br />

plants, heating plants, incinerators and exploitation of waste heat. Many of the items produced are used<br />

for other purposes, too, and for the storage and transport of materials and liquids.<br />

BRESSON a. s. continues in the traditional manufacture of boilers and associated equipment of boiler<br />

rooms. Beginning from the sixtieth when the collaboration between ČKD DUKLA and the then Tatra<br />

Kolín has started more, than 7,000 boiler units in the warm water, hot water or steam design, ranging<br />

from an output of 240 kg/hr. to 240 ton/hr., for incineration of lignite and hard coal, natural gas, town<br />

gas, heavy and light oils, industrial, hospital and municipal wastes have been marketed both in the<br />

country and abroad, including waste heat boilers.<br />

Production according to<br />

the company owned<br />

know-how<br />

Designing<br />

Manufacture according<br />

to the purchaser’s<br />

documentation<br />

Construction<br />

Services<br />

Studies,<br />

Technical<br />

Assistance<br />

Erections<br />

Inspections,<br />

Revisions<br />

Operation of power<br />

equipments<br />

2


BRESSON a. s. Production Range 2002<br />

Production Range<br />

Equipment Designed for Industrial and Heating Boiler<br />

Rooms<br />

Flue fire – tube boilers type BK T98 and BK T2000 are manufactured in both the steam and hot<br />

water designs for combustion of gaseous and liquid fuels as large-room units with natural circulation<br />

and overpressure combustion.<br />

Boilers are completely assembled, incl. their equipment, in the manufacturing plant, while model T2000<br />

is supplied with an economizer solely. Boilers are designed to be connected to device facilitating their<br />

operation without any continuous attendance.<br />

Output range: 1 – 14 ton/hr.; saturated or overheated steam: 220°C (on a individual basis up to<br />

280°); 1.4 MPa (on a individual basis up to 2 MPa); hot water: 150/70°C.<br />

Portable boilers type KTK are manufactured in both the steam and hot water designs for combustion<br />

of gaseous and liquid fuels. They are provided with water conducting tubes, are of a single-drum type<br />

with natural circulation, membrane design, assembled in the manufacturing plant. Boilers are supplied<br />

with the tube water heater and tube air heater, thus reaching an efficiency rate up to 95%.<br />

Output range of steam design: 8 – 25 ton/hr.; steam pressure: 0.9 – 1.4 MPa; steam temperature: 200<br />

– 250°C.<br />

Output range of, hot water design: 5 – 25 MW; pressure: 2.4 MPa; water temperature: 150/70°C.<br />

Portable boilers type OKP are manufactured in both the steam and hot water designs for combustion<br />

of gaseous and liquid fuels. They are provided with water conducting tubes, are of a double-drum type<br />

with natural circulation, membrane design, assembled in the manufacturing plant. Boilers are with<br />

ecomizers to achieve a high efficiency rate.<br />

Output range of steam design: 8 – 40 ton/hr.; steam pressure: 1.4; .2.5; 3.8 MPa; steam temperature:<br />

220; 380; 445°C (if on an individual basis, also with other parameters).<br />

Output range of hot water design: 5.6 – 17.5 MW; pressure: 1.4; 2.5; 3.8 MP; water temperature:<br />

150/70°C (if on an individual basis, also with other parameters).<br />

Supplementary water heaters (economizers) for boilers model BK T98 and OKP (designed with<br />

tubes, fins, made of cast iron).<br />

Stationary boilers - designed with water tubes, membrane type<br />

• Gas boilers up to an output of 150 ton/hr. , or a pressure of up to 9.6 MPa if required<br />

• Oil boilers up to an output of 150 ton/hr. or a pressure of up to 9.6 MPa if required<br />

• Powder boilers with an output of 35 – 150 ton/hr. or a pressure of up to 9.6 MPa if required<br />

• Fluid boilers DUKLAFLUID with an output of 8 – 50 ton/hr. for environmentally friendly combustion<br />

of primarily high-ash fuels<br />

• Fluid boilers IGNIFLUID with an output of 45 – 115 ton/hr. for combustion of hard coal with good<br />

calorific value<br />

3


BRESSON a. s. Production Range 2002<br />

• Grate boilers with a steam output of 4 – 50 ton/hr., in hot water design: 2.8 – 36 MW<br />

• Boilers for incineration of timber, farming and other wastes, and/or their combination with coal<br />

Medium-pressure heat exchangers PMD 10, 35, 70 and 110 are designed for heating and warming<br />

up of HUW [hot utility water] exchangers as a source of the technologic heat. Overpressure combustion of<br />

gaseous and liquid fuels.<br />

Output range: 150 – 1600 kg/hr; designed overpressure: 0.6 and 1.3 MPa.<br />

Hot-air exchangers type OTV are designed to heat air for the purpose of heating, drying or other<br />

technologic applications They are distinguished for their cylindrical design, are made of metal, without<br />

wall lining, with their front wall adjusted for a gas or oil burner.<br />

Output range: 290 – 1740 kW; outgoing adjustable temperature of the heated air within a range of 75 –<br />

150°C.<br />

High-speed steam developers G240 and G500 are through-flow boilers for production of the wet to<br />

saturated steam. Heat-exchanging surface is made by stainless coils, and the boiler is fitted with the<br />

monoblock burner designed for gaseous or liquid fuel.<br />

Steam output: 240 and 500 kg/hr.; designed overpressure: 0.6 MPa.<br />

Steam low-pressure boilers PGP are designed to produce technologic steam, and are applicable also<br />

in the event of low-pressure heating of buildings and TUV heat-exchanger. Overpressure combustion of<br />

gaseous and liquid fuels.<br />

Output range: 250 –2500 kW; designed overpressure: 0.05 MPa.<br />

Hot-water boilers KDVE 16 – 600 are designed for hot-water heating of buildings, production of<br />

technologic heat and warming up TUV heat-exchangers. Overpressure combustion of gaseous and<br />

liquid fuels.<br />

Output range: 160 – 6000 k; designed overpressure: 0.6 MPa; water temperature: 110/70°C.<br />

Thermal oil boilers KDVE - DUB, SPEC are used in case of the heat-conducting medium temperature<br />

more than 110°C and a pressure up to 0.3 MPa, for overpressure combustion of gaseous and liquid<br />

fuels.<br />

The heat-conducting medium (DUBOTERM) is designed for indirect heating in a closed pressure-free<br />

system up to an outlet temperature of 170°C. If required, the boiler type KDVE – DUB Special may be<br />

supplied for an outgoing temperature up to 200°C, and/or more.<br />

Output range: 400 – 1600 kW.<br />

Resistance type electric boilers model EOK 125R, 250 and 400 are used for direct or accumulated<br />

heating by means of electric current in closed hot-water systems.<br />

Output range: 125 – 390 kW.<br />

Boilers EOK 125 R are supplied including electric switchboard and mixing piece. For boilers EOK 250<br />

and 400 electric switchboards may be supplied separately.<br />

Mixing blocks for electric boilers EOK 125R.<br />

4


BRESSON a. s. Production Range 2002<br />

Boilers for exploitation of waste heat<br />

• exploitation of heat from combustion turbines<br />

• exploitation of combustibles from incinerators of municipal and industrial wastes<br />

• exploitation of heat from combustibles of glass works furnaces<br />

• additional surfaces for boilers - water or air heaters<br />

Accessories of boilers designed for solid fuels<br />

• belt and worm feeders or those with shovelling wheels<br />

• cooled worm feeders of glowing ash and ashes<br />

• multiple shaft feeders<br />

• bulk feeders and bulk conveyers<br />

• cooled bulk and worm conveyers<br />

• belt and worm conveyers and their accessories<br />

• steel tanks with vault disruption<br />

• hand-operated and mechanical closures<br />

• overpressure closures<br />

• wet slag removers of various designs – raking, plate, shovel<br />

• hammer mills with separators for milling lignite<br />

• moistening worms<br />

• articulated conveyers<br />

• low-speed bucket lift for ash materials<br />

Accessories of boilers for liquid fuels<br />

• tanks<br />

vertical and heated<br />

horizontal and heated<br />

horizontal for diesel oil<br />

running up type<br />

sedimentation type<br />

• heated and not heated filters Js 40 - 80 - 100 - 150<br />

• oil separators from the heated steam condensate<br />

100 – 1679 cu.m<br />

10 - 25 - 60 cu.m<br />

10 - 25 - 60 cu.m<br />

300 - 1000 l<br />

0.6 - 5 cu.m<br />

Pipes<br />

All the connecting pipes for water, steam, liquid fuels and gas, including distributors, compensators,<br />

supporting structures, suspensions, etc.<br />

For boiler completion:<br />

• air ducts, incl. shock absorbers<br />

• closing and regulating flap valves, rubber connections<br />

• combustible ducts, incl. explosion flap valves, steam compensators, supports and suspensions<br />

5


BRESSON a. s. Production Range 2002<br />

• steel stacks dia. 200 to 2500 mm, single-jacket or double-jacket types, with thermal insulation<br />

Supporting structures<br />

Steel supporting structures, building structures, platforms, transition racks, stairs and ladders<br />

Water treatment plants<br />

Clarifiers DUKLA (water clarification in the fluid flock bed dia. 2000 – 16000)<br />

Output range: 10 – 1000 cu.m/hr.<br />

Lamella separators – clearers (water clarification in the lamella system dia. 3200 - 5400).<br />

Output range: 20 – 240 cu.m/hr.<br />

Double-directional double-layer filters DDFI (double-layer pressure filtering in the double-component<br />

granular bed dia. 1400 - 3000).<br />

Output range: 60 – 280 cu.m/hr.<br />

Ionex filters IFS (for water deionizing, demineralising, dia. 600 – 1400).<br />

Output range: 10 – 60 cu.m/hr.<br />

Ionex filters IFS - D (double-layer “catex” bed for water softening and decarbonizing dia. 600 – 1400).<br />

Output range: 2.6 – 14.5 cu.m/hr.<br />

Ionex filters IF (for water deionizing, demineralising, dia. 1400 - 3000).<br />

Output range: 54 – 270 cu.m/hr.<br />

Ionex filters IFVP (for high flows, water deionizing, demineralizing and acid decarbonizing dia. 630 -<br />

2500).<br />

Output range: 6 – 260 cu.m/hr.<br />

Ionex filters IFDS (for deionizing, demineralizing, with double-flow reconstruction, dia. 1400 - 3000).<br />

Output range: 72 - 375 cu.m/hr.<br />

Ionex counterflow filters PIF (full ionex column for water demineralization, dia. 1000 - 3200).<br />

Output range: 30 - 320 cu.m/hr.<br />

Ionex double-chamber counterflow filters DPIF (two-stage ionex procedure based on full-column<br />

principle, dia. 1000 - 3200).<br />

Output range: 30 - 320 cu.m/hr.<br />

Straining parts for ionex filters (for all sizes and types).<br />

Fine filters JF (fine pressure filtering via. replaceable filtration cartridges dia. 380 - 800).<br />

6


BRESSON a. s. Production Range 2002<br />

Output range: 6 - 30 cu.m/hr.<br />

Rotary drum filters BF (filters in pressure piping, straining elements in the rotary drum, automatic<br />

washing, dia. 100 - 250).<br />

Output range: 100 - 620 cu.m/hr.<br />

Sand filter PF (water filtering in single- or multi-component granular bed dia. 600 - 3000).<br />

Output range: 3.5 - 83 cu.m/hr.<br />

Mixing filters SF (with internal regeneration, final demineralizing stage, dia. 600 - 2500).<br />

Output range: 10 - 234 cu.m/hr.<br />

Mixing filters SFE, SFEK (with external regeneration, final demineralizing stage or condensate<br />

treatment, with an option of pre-filtering in ionex bed, dia. 2000 - 2800).<br />

Output range: 200 - 480 cu.m/hr.<br />

Universal softening filters UZF (for softening or neutral decarbonizing, de-ironing, de-manganeseing,<br />

counterflow regeneration, ionex trap, dia. 600 - 3000).<br />

Output range: 11 - 360 cu.m/hr.<br />

Degassing nozzle (for thermal degassing of the feeding water, maximum overpressure: 0.07 MPa,<br />

maximum temperature: 150°C ).<br />

Output range: 1 - 32 cu.m/hr.<br />

Degassers KS (for thermal degassing of feeder water – two-stage system dia. 400 - 2500).<br />

Output range: 2.2 - 400 cu.m/hr.<br />

Flocculation chamber (pressure chambers with mixing, dia. 500 – 800 and 1800 - 3000).<br />

Output range: 5 – 20 cu.m/hr. and 70 - 350 cu.m/hr.<br />

Level oil collectors (collection of oil substances from the water level based on the indefinite moving<br />

wiped loop principle), with the loop of standard length of 6 meters, electrical input 120 W, water<br />

temperature from 10 – 60°C .<br />

Steam and hot water coolers (to take samples of water and steam), maximum sample overpressure<br />

16 MPa, maximum sample temperature 550°C, maximum temperature of cooled sample 50°C.<br />

Injectors for regeneration solutions (transport and dilution of regeneration solutions for ionex<br />

stations), driving water flow equal to 0.6 ; 1.6 ; 4 ; 8 ; 16 ; 40 cu.m/hr., respectively, DN 25 – 125.<br />

Injectors for loose materials (sand ionex and other fillings to filters and columns), driving water flow<br />

25 cu.m/hr., pressure up to 1 MPa, delivery head up to 8 meters).<br />

Pressure tanks – fans, aerators, expanders, releasers (equalizing tanks dia. 400 – 2500, working<br />

overpressure 0.6 – 1.6 MPa).<br />

Volume: 0.16 – 25 cu.m, and/or as required.<br />

7


BRESSON a. s. Production Range 2002<br />

Accessories - expansion chambers DN 15 – 100.<br />

Diluting salt pressure tanks (for preparation of the regeneration solution while softening, dia. 400 –<br />

1400).<br />

Volume: 90 – 1200 l.<br />

Tanks for external regeneration ER, ERT (for external ionex regeneration in both the not pressure<br />

and pressure designs, dia. 1200 - 2000).<br />

Ionex volume: 1.85 – 12.5 cu.m.<br />

Tanks for chemical solutions (mixers, calibrated vessels, dilution tanks made of steel, and/or<br />

rubberised, dia. 600 - 2500).<br />

Volume: 0.15 - 10 cu.m.<br />

Accessories – tippler of bags for tanks with chemical solutions<br />

Aeration towers (counterflow overpressure aeration units to remove CO 2 from water, dia. 600 - 3000).<br />

Output: 10 - 400 cu.m/hr.<br />

Tanks (steel or rubberised types, both pressure-free and pressure, vertical or horizontal designs, to<br />

store the feed water, condensate, demineralised water, etc., dia. 1000 – 3200, pressure 0.06 ; 0.6; 1<br />

MPa)<br />

Volume: 1 – 120 cu.m.<br />

Safety loops DN 65 - 200<br />

Pressure-free vertical storage tanks SB, SBCH (tanks of non aggressive liquids, with even or<br />

conical head, dia. 1800 - 7620, height 1790 - 7960)<br />

Volume: 4 - 360 cu.m.<br />

Heat exchangers - horizontal capillary exchangers for indirect heat exchange in heating equipments of<br />

water treatment plants, hot-water heating plants for water warming up or its cooling, condensates, etc.<br />

Design: water – water or water – steam, with capillaries made of stainless or brass material.<br />

Heat exchanging surface: 0.8 – 160 sq.m , working overpressure for pipes: 1 – 1.6 MPa and for the<br />

jacket: 0.06 – 1.06 MPa, designed temperature: 115 – 250°C.<br />

Kolín, January 2006<br />

8