BRESSON a. s. Production Range 2002<br />
BRESSON a. s. as the upholder of ČKD DUKLA and Strojírny Kolín [Enginering Works] manufactures<br />
and supplies a wide range of the equipment required by power engineering, industries, thermal power<br />
plants, heating plants, incinerators and exploitation of waste heat. Many of the items produced are used<br />
for other purposes, too, and for the storage and transport of materials and liquids.<br />
BRESSON a. s. continues in the traditional manufacture of boilers and associated equipment of boiler<br />
rooms. Beginning from the sixtieth when the collaboration between ČKD DUKLA and the then Tatra<br />
Kolín has started more, than 7,000 boiler units in the warm water, hot water or steam design, ranging<br />
from an output of 240 kg/hr. to 240 ton/hr., for incineration of lignite and hard coal, natural gas, town<br />
gas, heavy and light oils, industrial, hospital and municipal wastes have been marketed both in the<br />
country and abroad, including waste heat boilers.<br />
Production according to<br />
the company owned<br />
know-how<br />
Designing<br />
Manufacture according<br />
to the purchaser’s<br />
documentation<br />
Construction<br />
Services<br />
Studies,<br />
Technical<br />
Assistance<br />
Erections<br />
Inspections,<br />
Revisions<br />
Operation of power<br />
equipments<br />
2
BRESSON a. s. Production Range 2002<br />
Production Range<br />
Equipment Designed for Industrial and Heating Boiler<br />
Rooms<br />
Flue fire – tube boilers type BK T98 and BK T2000 are manufactured in both the steam and hot<br />
water designs for combustion of gaseous and liquid fuels as large-room units with natural circulation<br />
and overpressure combustion.<br />
Boilers are completely assembled, incl. their equipment, in the manufacturing plant, while model T2000<br />
is supplied with an economizer solely. Boilers are designed to be connected to device facilitating their<br />
operation without any continuous attendance.<br />
Output range: 1 – 14 ton/hr.; saturated or overheated steam: 220°C (on a individual basis up to<br />
280°); 1.4 MPa (on a individual basis up to 2 MPa); hot water: 150/70°C.<br />
Portable boilers type KTK are manufactured in both the steam and hot water designs for combustion<br />
of gaseous and liquid fuels. They are provided with water conducting tubes, are of a single-drum type<br />
with natural circulation, membrane design, assembled in the manufacturing plant. Boilers are supplied<br />
with the tube water heater and tube air heater, thus reaching an efficiency rate up to 95%.<br />
Output range of steam design: 8 – 25 ton/hr.; steam pressure: 0.9 – 1.4 MPa; steam temperature: 200<br />
– 250°C.<br />
Output range of, hot water design: 5 – 25 MW; pressure: 2.4 MPa; water temperature: 150/70°C.<br />
Portable boilers type OKP are manufactured in both the steam and hot water designs for combustion<br />
of gaseous and liquid fuels. They are provided with water conducting tubes, are of a double-drum type<br />
with natural circulation, membrane design, assembled in the manufacturing plant. Boilers are with<br />
ecomizers to achieve a high efficiency rate.<br />
Output range of steam design: 8 – 40 ton/hr.; steam pressure: 1.4; .2.5; 3.8 MPa; steam temperature:<br />
220; 380; 445°C (if on an individual basis, also with other parameters).<br />
Output range of hot water design: 5.6 – 17.5 MW; pressure: 1.4; 2.5; 3.8 MP; water temperature:<br />
150/70°C (if on an individual basis, also with other parameters).<br />
Supplementary water heaters (economizers) for boilers model BK T98 and OKP (designed with<br />
tubes, fins, made of cast iron).<br />
Stationary boilers - designed with water tubes, membrane type<br />
• Gas boilers up to an output of 150 ton/hr. , or a pressure of up to 9.6 MPa if required<br />
• Oil boilers up to an output of 150 ton/hr. or a pressure of up to 9.6 MPa if required<br />
• Powder boilers with an output of 35 – 150 ton/hr. or a pressure of up to 9.6 MPa if required<br />
• Fluid boilers DUKLAFLUID with an output of 8 – 50 ton/hr. for environmentally friendly combustion<br />
of primarily high-ash fuels<br />
• Fluid boilers IGNIFLUID with an output of 45 – 115 ton/hr. for combustion of hard coal with good<br />
calorific value<br />
3
BRESSON a. s. Production Range 2002<br />
• Grate boilers with a steam output of 4 – 50 ton/hr., in hot water design: 2.8 – 36 MW<br />
• Boilers for incineration of timber, farming and other wastes, and/or their combination with coal<br />
Medium-pressure heat exchangers PMD 10, 35, 70 and 110 are designed for heating and warming<br />
up of HUW [hot utility water] exchangers as a source of the technologic heat. Overpressure combustion of<br />
gaseous and liquid fuels.<br />
Output range: 150 – 1600 kg/hr; designed overpressure: 0.6 and 1.3 MPa.<br />
Hot-air exchangers type OTV are designed to heat air for the purpose of heating, drying or other<br />
technologic applications They are distinguished for their cylindrical design, are made of metal, without<br />
wall lining, with their front wall adjusted for a gas or oil burner.<br />
Output range: 290 – 1740 kW; outgoing adjustable temperature of the heated air within a range of 75 –<br />
150°C.<br />
High-speed steam developers G240 and G500 are through-flow boilers for production of the wet to<br />
saturated steam. Heat-exchanging surface is made by stainless coils, and the boiler is fitted with the<br />
monoblock burner designed for gaseous or liquid fuel.<br />
Steam output: 240 and 500 kg/hr.; designed overpressure: 0.6 MPa.<br />
Steam low-pressure boilers PGP are designed to produce technologic steam, and are applicable also<br />
in the event of low-pressure heating of buildings and TUV heat-exchanger. Overpressure combustion of<br />
gaseous and liquid fuels.<br />
Output range: 250 –2500 kW; designed overpressure: 0.05 MPa.<br />
Hot-water boilers KDVE 16 – 600 are designed for hot-water heating of buildings, production of<br />
technologic heat and warming up TUV heat-exchangers. Overpressure combustion of gaseous and<br />
liquid fuels.<br />
Output range: 160 – 6000 k; designed overpressure: 0.6 MPa; water temperature: 110/70°C.<br />
Thermal oil boilers KDVE - DUB, SPEC are used in case of the heat-conducting medium temperature<br />
more than 110°C and a pressure up to 0.3 MPa, for overpressure combustion of gaseous and liquid<br />
fuels.<br />
The heat-conducting medium (DUBOTERM) is designed for indirect heating in a closed pressure-free<br />
system up to an outlet temperature of 170°C. If required, the boiler type KDVE – DUB Special may be<br />
supplied for an outgoing temperature up to 200°C, and/or more.<br />
Output range: 400 – 1600 kW.<br />
Resistance type electric boilers model EOK 125R, 250 and 400 are used for direct or accumulated<br />
heating by means of electric current in closed hot-water systems.<br />
Output range: 125 – 390 kW.<br />
Boilers EOK 125 R are supplied including electric switchboard and mixing piece. For boilers EOK 250<br />
and 400 electric switchboards may be supplied separately.<br />
Mixing blocks for electric boilers EOK 125R.<br />
4
BRESSON a. s. Production Range 2002<br />
Boilers for exploitation of waste heat<br />
• exploitation of heat from combustion turbines<br />
• exploitation of combustibles from incinerators of municipal and industrial wastes<br />
• exploitation of heat from combustibles of glass works furnaces<br />
• additional surfaces for boilers - water or air heaters<br />
Accessories of boilers designed for solid fuels<br />
• belt and worm feeders or those with shovelling wheels<br />
• cooled worm feeders of glowing ash and ashes<br />
• multiple shaft feeders<br />
• bulk feeders and bulk conveyers<br />
• cooled bulk and worm conveyers<br />
• belt and worm conveyers and their accessories<br />
• steel tanks with vault disruption<br />
• hand-operated and mechanical closures<br />
• overpressure closures<br />
• wet slag removers of various designs – raking, plate, shovel<br />
• hammer mills with separators for milling lignite<br />
• moistening worms<br />
• articulated conveyers<br />
• low-speed bucket lift for ash materials<br />
Accessories of boilers for liquid fuels<br />
• tanks<br />
vertical and heated<br />
horizontal and heated<br />
horizontal for diesel oil<br />
running up type<br />
sedimentation type<br />
• heated and not heated filters Js 40 - 80 - 100 - 150<br />
• oil separators from the heated steam condensate<br />
100 – 1679 cu.m<br />
10 - 25 - 60 cu.m<br />
10 - 25 - 60 cu.m<br />
300 - 1000 l<br />
0.6 - 5 cu.m<br />
Pipes<br />
All the connecting pipes for water, steam, liquid fuels and gas, including distributors, compensators,<br />
supporting structures, suspensions, etc.<br />
For boiler completion:<br />
• air ducts, incl. shock absorbers<br />
• closing and regulating flap valves, rubber connections<br />
• combustible ducts, incl. explosion flap valves, steam compensators, supports and suspensions<br />
5
BRESSON a. s. Production Range 2002<br />
• steel stacks dia. 200 to 2500 mm, single-jacket or double-jacket types, with thermal insulation<br />
Supporting structures<br />
Steel supporting structures, building structures, platforms, transition racks, stairs and ladders<br />
Water treatment plants<br />
Clarifiers DUKLA (water clarification in the fluid flock bed dia. 2000 – 16000)<br />
Output range: 10 – 1000 cu.m/hr.<br />
Lamella separators – clearers (water clarification in the lamella system dia. 3200 - 5400).<br />
Output range: 20 – 240 cu.m/hr.<br />
Double-directional double-layer filters DDFI (double-layer pressure filtering in the double-component<br />
granular bed dia. 1400 - 3000).<br />
Output range: 60 – 280 cu.m/hr.<br />
Ionex filters IFS (for water deionizing, demineralising, dia. 600 – 1400).<br />
Output range: 10 – 60 cu.m/hr.<br />
Ionex filters IFS - D (double-layer “catex” bed for water softening and decarbonizing dia. 600 – 1400).<br />
Output range: 2.6 – 14.5 cu.m/hr.<br />
Ionex filters IF (for water deionizing, demineralising, dia. 1400 - 3000).<br />
Output range: 54 – 270 cu.m/hr.<br />
Ionex filters IFVP (for high flows, water deionizing, demineralizing and acid decarbonizing dia. 630 -<br />
2500).<br />
Output range: 6 – 260 cu.m/hr.<br />
Ionex filters IFDS (for deionizing, demineralizing, with double-flow reconstruction, dia. 1400 - 3000).<br />
Output range: 72 - 375 cu.m/hr.<br />
Ionex counterflow filters PIF (full ionex column for water demineralization, dia. 1000 - 3200).<br />
Output range: 30 - 320 cu.m/hr.<br />
Ionex double-chamber counterflow filters DPIF (two-stage ionex procedure based on full-column<br />
principle, dia. 1000 - 3200).<br />
Output range: 30 - 320 cu.m/hr.<br />
Straining parts for ionex filters (for all sizes and types).<br />
Fine filters JF (fine pressure filtering via. replaceable filtration cartridges dia. 380 - 800).<br />
6
BRESSON a. s. Production Range 2002<br />
Output range: 6 - 30 cu.m/hr.<br />
Rotary drum filters BF (filters in pressure piping, straining elements in the rotary drum, automatic<br />
washing, dia. 100 - 250).<br />
Output range: 100 - 620 cu.m/hr.<br />
Sand filter PF (water filtering in single- or multi-component granular bed dia. 600 - 3000).<br />
Output range: 3.5 - 83 cu.m/hr.<br />
Mixing filters SF (with internal regeneration, final demineralizing stage, dia. 600 - 2500).<br />
Output range: 10 - 234 cu.m/hr.<br />
Mixing filters SFE, SFEK (with external regeneration, final demineralizing stage or condensate<br />
treatment, with an option of pre-filtering in ionex bed, dia. 2000 - 2800).<br />
Output range: 200 - 480 cu.m/hr.<br />
Universal softening filters UZF (for softening or neutral decarbonizing, de-ironing, de-manganeseing,<br />
counterflow regeneration, ionex trap, dia. 600 - 3000).<br />
Output range: 11 - 360 cu.m/hr.<br />
Degassing nozzle (for thermal degassing of the feeding water, maximum overpressure: 0.07 MPa,<br />
maximum temperature: 150°C ).<br />
Output range: 1 - 32 cu.m/hr.<br />
Degassers KS (for thermal degassing of feeder water – two-stage system dia. 400 - 2500).<br />
Output range: 2.2 - 400 cu.m/hr.<br />
Flocculation chamber (pressure chambers with mixing, dia. 500 – 800 and 1800 - 3000).<br />
Output range: 5 – 20 cu.m/hr. and 70 - 350 cu.m/hr.<br />
Level oil collectors (collection of oil substances from the water level based on the indefinite moving<br />
wiped loop principle), with the loop of standard length of 6 meters, electrical input 120 W, water<br />
temperature from 10 – 60°C .<br />
Steam and hot water coolers (to take samples of water and steam), maximum sample overpressure<br />
16 MPa, maximum sample temperature 550°C, maximum temperature of cooled sample 50°C.<br />
Injectors for regeneration solutions (transport and dilution of regeneration solutions for ionex<br />
stations), driving water flow equal to 0.6 ; 1.6 ; 4 ; 8 ; 16 ; 40 cu.m/hr., respectively, DN 25 – 125.<br />
Injectors for loose materials (sand ionex and other fillings to filters and columns), driving water flow<br />
25 cu.m/hr., pressure up to 1 MPa, delivery head up to 8 meters).<br />
Pressure tanks – fans, aerators, expanders, releasers (equalizing tanks dia. 400 – 2500, working<br />
overpressure 0.6 – 1.6 MPa).<br />
Volume: 0.16 – 25 cu.m, and/or as required.<br />
7
BRESSON a. s. Production Range 2002<br />
Accessories - expansion chambers DN 15 – 100.<br />
Diluting salt pressure tanks (for preparation of the regeneration solution while softening, dia. 400 –<br />
1400).<br />
Volume: 90 – 1200 l.<br />
Tanks for external regeneration ER, ERT (for external ionex regeneration in both the not pressure<br />
and pressure designs, dia. 1200 - 2000).<br />
Ionex volume: 1.85 – 12.5 cu.m.<br />
Tanks for chemical solutions (mixers, calibrated vessels, dilution tanks made of steel, and/or<br />
rubberised, dia. 600 - 2500).<br />
Volume: 0.15 - 10 cu.m.<br />
Accessories – tippler of bags for tanks with chemical solutions<br />
Aeration towers (counterflow overpressure aeration units to remove CO 2 from water, dia. 600 - 3000).<br />
Output: 10 - 400 cu.m/hr.<br />
Tanks (steel or rubberised types, both pressure-free and pressure, vertical or horizontal designs, to<br />
store the feed water, condensate, demineralised water, etc., dia. 1000 – 3200, pressure 0.06 ; 0.6; 1<br />
MPa)<br />
Volume: 1 – 120 cu.m.<br />
Safety loops DN 65 - 200<br />
Pressure-free vertical storage tanks SB, SBCH (tanks of non aggressive liquids, with even or<br />
conical head, dia. 1800 - 7620, height 1790 - 7960)<br />
Volume: 4 - 360 cu.m.<br />
Heat exchangers - horizontal capillary exchangers for indirect heat exchange in heating equipments of<br />
water treatment plants, hot-water heating plants for water warming up or its cooling, condensates, etc.<br />
Design: water – water or water – steam, with capillaries made of stainless or brass material.<br />
Heat exchanging surface: 0.8 – 160 sq.m , working overpressure for pipes: 1 – 1.6 MPa and for the<br />
jacket: 0.06 – 1.06 MPa, designed temperature: 115 – 250°C.<br />
Kolín, January 2006<br />