Operation

menzimuck

Operation

Menzi Muck A61

Examples of different blink codes

Case 1: short ­ long ­ 8x short

This means that the output module for the right­hand chassis functions has failed.

Check the connector XCT01 and the plug XCA02.

Case 2: 3x long ­ 7x short

This means that the output module for the left­hand chassis functions has failed

Check the connector XCT01 and the plug XCA01.

Case 3: 7x short ­ long ­ long ­ short

Both joysticks are out of service, causing all switch functions to fail. We recommend that you check the

joystick supply fuse and connectors.

Before contacting your sales agency, check that all fuses, cables and connectors on the non­operational

modules are connected correctly.