OMNI 375 SERIES VALVES<br />
Adjustable Electronic Micro Timer - .1 to 100 seconds<br />
Timer styles available: On - delay<br />
Off - delay<br />
Interval<br />
Cycle - timer<br />
FEATURES: General Description<br />
• Wide range of operating voltages, 6-24 VDC,<br />
12, 24 & 120 VAC<br />
• Timing circuit has typical temperature stability<br />
of .005% per deg. C at 25 deg. C.<br />
• Wide range of adjustability, .1 to 100 seconds<br />
in various versions. For longer timing functions<br />
consult factory.<br />
• Indicator lights available on all units.<br />
• Solid state timer guarantees 500 KHz timing<br />
operation, no moving parts to wear out giving<br />
millions of trouble-free cycles.<br />
• Operating temperature range, -20 o to +50 o C<br />
• Transient protection.<br />
• High impact fiber-reinforced poly-amide nylon<br />
enclosure. Immersion resistant adjusting screws<br />
indicate adjustment extremes with a “tick” and<br />
can not be over adjusted. The recessed adjusting<br />
screws minimize tampering and can be epoxied<br />
over after final adjustment is made.<br />
• 15 turn adjustability for time selection.<br />
• All timers are available with electrical override.<br />
Time Range: A = .1 - 5 seconds<br />
B = .5 - 20 seconds<br />
C = .5 - 40 seconds<br />
ON DELAY: 50 Operator<br />
Upon application of power to the<br />
input terminals, the time delay begins.<br />
At the end of the preset time delay<br />
the coil becomes energized. Reset<br />
occurs when power is removed from<br />
the input terminals.<br />
POWER<br />
COIL<br />
ON<br />
OFF<br />
ON<br />
OFF<br />
53<br />
OFF DELAY: 51 Operator<br />
Power is applied to the timer at all<br />
times. Upon closure of the normally<br />
open trigger switch, coil becomes<br />
energized and timing begins. At the<br />
end of the preset time delay, power<br />
is removed from the coil. Reset occurs<br />
when trigger switch is closed.<br />
INTERVAL: 52 Operator<br />
Upon application of power, the coil is<br />
immediately energized and timing begins.<br />
At the end of the selected time, power is<br />
removed from the coil. Reset occurs when<br />
power is removed from the input terminals.<br />
CYCLE TIMER: 53 Operator<br />
Upon application of power to the input<br />
terminals, OFF cycle is initiated. At the end<br />
of the preset off time, coil is energized<br />
and ON cycle begins. At the end of the preset<br />
on time, power is removed and a new cycle<br />
begins. Cycling continues until power is<br />
removed from input terminals.<br />
ON<br />
POWER<br />
OFF<br />
ON<br />
SWITCH<br />
OFF<br />
COIL<br />
ON<br />
OFF<br />
ON<br />
POWER<br />
OFF<br />
COIL<br />
ON<br />
OFF<br />
ON<br />
POWER<br />
OFF<br />
COIL<br />
ON<br />
OFF