OMNI 375 SERIES VALVES<br />

Adjustable Electronic Micro Timer - .1 to 100 seconds<br />

Timer styles available: On - delay<br />

Off - delay<br />

Interval<br />

Cycle - timer<br />

FEATURES: General Description<br />

• Wide range of operating voltages, 6-24 VDC,<br />

12, 24 & 120 VAC<br />

• Timing circuit has typical temperature stability<br />

of .005% per deg. C at 25 deg. C.<br />

• Wide range of adjustability, .1 to 100 seconds<br />

in various versions. For longer timing functions<br />

consult factory.<br />

• Indicator lights available on all units.<br />

• Solid state timer guarantees 500 KHz timing<br />

operation, no moving parts to wear out giving<br />

millions of trouble-free cycles.<br />

• Operating temperature range, -20 o to +50 o C<br />

• Transient protection.<br />

• High impact fiber-reinforced poly-amide nylon<br />

enclosure. Immersion resistant adjusting screws<br />

indicate adjustment extremes with a “tick” and<br />

can not be over adjusted. The recessed adjusting<br />

screws minimize tampering and can be epoxied<br />

over after final adjustment is made.<br />

• 15 turn adjustability for time selection.<br />

• All timers are available with electrical override.<br />

Time Range: A = .1 - 5 seconds<br />

B = .5 - 20 seconds<br />

C = .5 - 40 seconds<br />

ON DELAY: 50 Operator<br />

Upon application of power to the<br />

input terminals, the time delay begins.<br />

At the end of the preset time delay<br />

the coil becomes energized. Reset<br />

occurs when power is removed from<br />

the input terminals.<br />

POWER<br />

COIL<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

53<br />

OFF DELAY: 51 Operator<br />

Power is applied to the timer at all<br />

times. Upon closure of the normally<br />

open trigger switch, coil becomes<br />

energized and timing begins. At the<br />

end of the preset time delay, power<br />

is removed from the coil. Reset occurs<br />

when trigger switch is closed.<br />

INTERVAL: 52 Operator<br />

Upon application of power, the coil is<br />

immediately energized and timing begins.<br />

At the end of the selected time, power is<br />

removed from the coil. Reset occurs when<br />

power is removed from the input terminals.<br />

CYCLE TIMER: 53 Operator<br />

Upon application of power to the input<br />

terminals, OFF cycle is initiated. At the end<br />

of the preset off time, coil is energized<br />

and ON cycle begins. At the end of the preset<br />

on time, power is removed and a new cycle<br />

begins. Cycling continues until power is<br />

removed from input terminals.<br />

ON<br />

POWER<br />

OFF<br />

ON<br />

SWITCH<br />

OFF<br />

COIL<br />

ON<br />

OFF<br />

ON<br />

POWER<br />

OFF<br />

COIL<br />

ON<br />

OFF<br />

ON<br />

POWER<br />

OFF<br />

COIL<br />

ON<br />

OFF