<strong>Factors</strong> <strong>that</strong> <strong>Affect</strong><br />

<strong>Operability</strong>: Maynilad<br />

Netbase<br />

ARIEL DAYANGHIRANG<br />

NRW MGT SOFTWARE SPECIALIST, miya asia


Maynilad NRW Program<br />

132 Zones<br />

9<br />

10<br />

1,000DMAs<br />

8<br />

9-1<br />

9-2<br />

10-3<br />

10-2<br />

10-1<br />

9-3<br />

10-6<br />

9-4<br />

10-4<br />

9-6 9-5 9-7<br />

10-7<br />

10-5<br />

8-1<br />

9-8<br />

8-3<br />

9-9<br />

8-2<br />

8-7<br />

8-6<br />

8-5<br />

8-4<br />

20,000-50,000 connections 500-1,200 connections<br />

Around 800 DMAs Established<br />

2


Status of DMAs in Maynilad<br />

<br />

807 DMAs have been established and integrated in<br />

Netbase<br />

460 District Meter Points are logged and 91%<br />

provide good quality data<br />

<br />

374 Critical Monitoring Points have been set-up<br />

and 98% provide good quality data<br />

3


DMA Setup <strong>Affect</strong>ing <strong>Operability</strong><br />

DMA<br />

4


DMA Setup <strong>Affect</strong>ing <strong>Operability</strong><br />

MRUs


DMA Setup <strong>Affect</strong>ing <strong>Operability</strong><br />

MRUs


DMA Setup <strong>Affect</strong>ing <strong>Operability</strong><br />

Meter Point<br />

7


DMA Setup <strong>Affect</strong>ing <strong>Operability</strong><br />

.<br />

Critical Point<br />

8


The Effect of Night-use on <strong>Operability</strong><br />

• The consumptions of very large users makes it<br />

difficult to estimate the night leakage and therefore<br />

affects <strong>Operability</strong><br />

• In Maynilad there are approximately 1400 large<br />

users<br />

• Currently the top 100 large users are continuously<br />

logged which helps with improving <strong>Operability</strong><br />

• Currently domestic and non-domestic night-use is<br />

being investigated so as to be estimated as part of<br />

the water balance, this will also improve<br />

<strong>Operability</strong><br />

9


Example - effect of Large Users on<br />

Night-use<br />

• A logged large user where the night use varies<br />

significantly<br />

10


Example - effect of Large Users on<br />

Night-use<br />

• A logged large user where the night use is almost<br />

zero because of an elevated tank and pump.<br />

11


Address the variability for domestic nightuse<br />

12


Addressing field conditions which affect<br />

<strong>Operability</strong><br />

Photos copyright MWSI Integrated Management; Discussed in Earlier Session by Johnny<br />

Gil Ascan of MWSI IMM Department<br />

Photos copyright Abe Longued, MWSI Sampaloc BA NRW<br />

13


Example of an Operable DMA<br />

(18-SAM01G) showing the outbreak of a burst<br />

14


Non-visible Leak detected along P.Guevarra St.<br />

by BA Leak Detection Team and subsequently<br />

repaired<br />

Photos copyright MWSI Sampaloc BA NRW<br />

15


Another example of an operable DMA 18-<br />

SAM01C<br />

16


Non-visible Leak Detected and Repaired<br />

Photos copyright MWSI Sampaloc BA NRW