Air Treatment Division<br />

„We have some on stock ...“<br />

db^=jìäíáMAXX ® =moljmq<br />

Air Treatment Units on Call


Short Description/Range Overview<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

Quick solution for heating of industrial halls<br />

For more than 50 years air treatment units of series <strong>GEA</strong> <strong>MultiMAXX</strong> ® have<br />

been successfully used on industrial premises and due to their reliability meet<br />

all customer requirements. High flexibility and personalized adjustment to<br />

customer wishes constitute the most important advantages of<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® air treatment units. Irrespective of functional requirements<br />

like heating or cooling, circulating air or mixed air operation mode - with the<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® you are always making the right choice.<br />

Together with the present catalogue we are presenting a part of our programme<br />

that will to the largest extent cover your requirements in most <strong>com</strong>mon<br />

applications.<br />

For classical heating of industrial halls we are offering the <strong>GEA</strong> <strong>MultiMAXX</strong> ®<br />

<strong>PROMPT</strong> designed for operating voltage of 400V ~ with installed fan switch.<br />

<strong>PROMPT</strong> means easy selection and quick availabilty and at the same time<br />

ensuring high quality.<br />

Please select the basic unit and with it the basic discharge for wall suspension,<br />

profile discharge (wall or ceiling installation) or double side discharge (ceiling<br />

suspension) as well as our suspension of type Compact C. We are also offering<br />

a suitable 2-speed switch unit MC302, room thermostat or an industrial<br />

facitilty thermostat as well as an intermediate terminal box for operating several<br />

units.<br />

Select the right <strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> depending on the temperature<br />

requirements and after that use the relevant sales/order number to place your<br />

order with us. It is essential, of course, that the <strong>com</strong>prehensive range of <strong>com</strong>ponents<br />

like heat exchangers, motors and discharge parts as well as miscellaneous<br />

accessories is available.<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

with<br />

Profile<br />

discharge<br />

wall/ceiling<br />

Basic<br />

discharge<br />

wall<br />

Basic<br />

discharge<br />

ceiling<br />

two sides<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 12 P 12 P P 12 W P 12 D<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 22 P 22 P P 22 W P 22 D<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 31 P 31 P P 31 W P 31 D<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 32 P 32 P P 32 W P 32 D<br />

2 PR-2007-0527GB • Subject to modifications • Status 11/2007


<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

Unit Description<br />

Wide blade fan<br />

Axial fan with external rotor motor for normal pressure and sound requirements<br />

as well as basket with ingrated contact protection grille according to<br />

DIN EN 294. Alumunium wide blades, balanced at factory, maintenance free<br />

with humidity protected motor wired on terminal box.<br />

Protection type IP 54, thermal class F, thermal contact and fan switch.<br />

Flow nozzle is performed as short nozzle.<br />

Operating limits:<br />

Air intake temperature:<br />

-20° to +45°C<br />

Cu/Al – heat exchanger (HE)<br />

Heat exchanger for heating with warm water pump and suitable for air with low<br />

dirt content. Made of copper pipes with moulded aluminium fins,<br />

fin spacing 2,5 mm.<br />

Operating limits:<br />

Maximum operating<br />

temperature:<br />

Maximum operating pressure:<br />

130 °C<br />

16 bar<br />

Profile discharge (wall or ceiling installation)<br />

The profile discharge made of galvanized aluminium air deflection louvres is<br />

designed for increasing air throw. In such a way the unit can be easily installed<br />

at average mounting heights.<br />

The profile discharge can be manually adjusted, is self locking and variable for<br />

ceiling and wall installation.<br />

Wall basic discharge<br />

With wall basic discharge galvanized steel sheet fins make it possible to deflect<br />

conditioned air at the needed discharge angle.<br />

Each fin of the basic discharge can be adjusted manually and is self locking.<br />

Basic discharge two sides<br />

Discharge device for low installation heights. Galvanized steel sheet fins make<br />

it possible to deflect conditioned air at two needed discharge angles.<br />

PR-2007-0527GB • Subject to modifications • Status 11/2007 3


Unit Data<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 12 (400 V~)<br />

Speed/RPM [min -1 ] 1050 1320<br />

Max. power consumption [kW] 0,09 0,14<br />

Max. current consumption [A] 0,28 0,49<br />

Sound pressure * [dB(A)] 52 56<br />

with profile discharge (wall or ceiling)<br />

Air volume flow [m 3 /h] 1580 2010<br />

Inlet/<br />

return temperature<br />

Suction<br />

temp. [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 14 32 5,2/4,7 16 29 6,4/6,3<br />

Warm water pump<br />

70/50<br />

+ 15 11 36 5,7/5,3 13 34 6,9/7,1<br />

+ 18 10 38 5,8/5,5 12 36 7,1/7,4<br />

+ 20 10 38 6,0/5,7 11 36 7,2/7,7<br />

+ 5 18 38 4,9/4,2 20 35 5,9/5,7<br />

Warm water pump<br />

80/60<br />

+ 15 15 42 5,2/4,7 17 40 6,3/6,2<br />

+ 18 14 44 5,3/4,8 16 41 6,4/6,4<br />

+ 20 13 45 5,4/4,9 15 42 6,5/6,6<br />

+ 5 21 44 4,6/3,9 24 40 5,6/5,2<br />

Warm water pump<br />

90/70<br />

+ 15 18 49 4,9/4,2 21 45 5,9/5,6<br />

+ 18 17 47 4,9/4,3 19 50 6,0/5,8<br />

with basic discharge wall/ceiling two sides<br />

+ 20 16 48 5,0/4,4 19 51 6,1/5,9<br />

Air volume flow [m 3 /h] 1750 2200<br />

Inlet/<br />

return temperature<br />

Suction<br />

temp [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 15 31 4,7/3,9 17 28 5,7/5,1<br />

Warm water pump<br />

70/50<br />

+ 15 12 35 5,1/4,3 14 33 6,2/5,8<br />

+ 18 11 37 5,3/4,5 12 35 6,4/6,0<br />

+ 20 10 37 5,4/4,7 12 36 6,5/6,2<br />

+ 5 19 37 4,4/3,5 21 34 5,3/4,6<br />

Warm water pump<br />

80/60<br />

+ 15 16 41 4,7/3,8 18 39 5,7/5,1<br />

+ 18 15 43 4,8/3,9 17 40 5,8/5,2<br />

+ 20 14 44 4,9/4,0 16 41 5,9/5,4<br />

+ 5 22 43 4,2/3,2 25 39 5,0/4,3<br />

Warm water pump<br />

90/70<br />

+ 15 19 47 4,4/3,4 22 44 5,3/4,6<br />

+ 18 18 49 4,5/3,5 21 46 5,4/4,7<br />

+ 20 17 49 4,5/3,6 20 47 5,5/4,8<br />

* Sound pressure:<br />

Approximate values at the distance of 5 m laterally from the unit, at maximum air volume flow and low reflection room.<br />

Industrial facility volume 1500 m³/h, absorbtion surface 200 m² Sabin, hemispherical radiation = radiation factor 2.<br />

Due to room/space features these values can be significantly influenced in terms of better or worse indicators.<br />

4 PR-2007-0527GB • Subject to modifications • Status 11/2007


<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

Unit Data<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 22 (400 V~)<br />

Speed/RPM [min -1 ] 890 1270<br />

Max. power consumption [kW] 0,19 0,29<br />

Max. current consumption [A] 0,35 0,61<br />

Sound pressure * [dB(A)] 54 61<br />

with profile discharge (wall or ceiling)<br />

Air volume flow [m 3 /h] 2400 3280<br />

Inlet/<br />

return temperature<br />

Warm water pump<br />

70/50<br />

Suction<br />

temp. [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 22 32 5,8/5,3 26 29 7,5/7,8<br />

+ 15 17 37 6,3/6,0 21 34 8,1/8,8<br />

+ 18 16 38 6,4/6,2 19 35 8,3/9,1<br />

+ 20 15 39 6,6/6,4 18 36 8,5/9,4<br />

+ 5 27 39 5,4/4,8 32 34 7,0/7,1<br />

Warm water pump<br />

80/60<br />

+ 15 23 43 5,8/5,3 27 39 7,4/7,7<br />

+ 18 21 44 5,9/5,4 25 41 7,6/8,0<br />

+ 20 20 45 6,0/5,6 24 42 7,7/8,1<br />

+ 5 32 44 5,1/4,4 38 39 6,6/6,5<br />

Warm water pump<br />

90/70<br />

+ 15 27 49 5,4/4,8 33 45 7,0/7,0<br />

+ 18 26 50 5,5/4,9 31 46 7,1/7,2<br />

+ 20 25 51 5,6/5,0 30 47 7,2/7,3<br />

with basic discharge wall/ceiling two sides<br />

Air volume flow [m 3 /h] 2660 3620<br />

Inlet/<br />

return temperature<br />

Warm water pump<br />

70/50<br />

Suction<br />

temp [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 23 31 5,3/4,3 28 28 6,8/6,3<br />

+ 15 19 36 5,7/4,9 22 33 7,3/7,2<br />

+ 18 17 37 5,8/5,1 20 35 7,5/7,5<br />

+ 20 16 38 5,9/5,2 19 36 7,7/7,7<br />

+ 5 29 37 4,9/3,9 34 33 6,3/5,7<br />

Warm water pump<br />

80/60<br />

+ 15 24 42 5,2/4,3 28 38 6,7/6,3<br />

+ 18 22 43 5,3/4,4 27 40 6,9/6,5<br />

+ 20 21 44 5,4/4,5 25 41 7,0/6,6<br />

+ 5 34 43 4,7/3,6 40 38 6,0/5,3<br />

Warm water pump<br />

90/70<br />

+ 15 29 48 4,9/3,9 34 43 6,3/5,7<br />

+ 18 28 49 5,0/4,0 33 45 6,4/5,9<br />

+ 20 27 50 5,0/4,1 32 46 6,5/6,0<br />

* Sound pressure:<br />

Approximate values at the distance of 5 m laterally from the unit, at maximum air volume flow and low reflection room.<br />

Industrial facility volume 1500 m³/h, absorbtion surface 200 m² Sabin, hemispherical radiation = radiation factor 2.<br />

Due to room/space features these values can be significantly influenced in terms of better or worse indicators.<br />

PR-2007-0527GB • Subject to modifications • Status 11/2007 5


Unit Data<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 31 (400 V~)<br />

Speed/RPM [min -1 ] 660 900<br />

Max. power consumption [kW] 0,20 0,31<br />

Max. current consumption [A] 0,50 0,88<br />

Sound pressure * [dB(A)] 55 61<br />

with profile discharge (wall or ceiling)<br />

Air volume flow [m 3 /h] 4130 5180<br />

Inlet/<br />

return temperature<br />

Warm water pump<br />

70/50<br />

Suction<br />

temp. [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 22 21 8,1/8,5 24 19 9,8/11,3<br />

+ 15 17 28 8,7/9,5 19 26 10,6/12,6<br />

+ 18 16 30 9,0/9,9 18 28 10,9/13,2<br />

+ 20 15 31 9,2/10,2 17 30 11,1/13,6<br />

+ 5 26 24 7,6/7,7 30 22 9,2/10,2<br />

Warm water pump<br />

80/60<br />

+ 15 22 31 8,1/8,4 25 29 9,8/11,2<br />

+ 18 21 33 8,2/8,7 23 31 10,0/11,5<br />

+ 20 20 35 10,1/11,8 22 33 8,4/8,9<br />

+ 5 31 28 7,2/7,1 35 25 8,7/9,4<br />

Warm water pump<br />

90/70<br />

+ 15 27 34 7,6/7,6 30 32 9,2/10,2<br />

+ 18 26 37 7,7/7,8 28 34 9,3/10,4<br />

+ 20 25 38 7,8/8,0 27 36 9,4/10,6<br />

with basic discharge wall/ceiling two sides<br />

Air volume flow [m 3 /h] 4850 5840<br />

Inlet/<br />

return temperature<br />

Warm water pump<br />

70/50<br />

Suction<br />

temp [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 23 19 7,8/7,4 26 18 9,1/9,5<br />

+ 15 19 27 8,3 20 25 9,8/10,7<br />

+ 18 17 29 8,6 19 28 10,1/11,1<br />

+ 20 16 30 8,8/8,9 18 29 10,3/11,4<br />

+ 5 29 23 7,3/6,7 31 21 8,5/8,6<br />

Warm water pump<br />

80/60<br />

+ 15 24 30 7,7/7,3 26 28 9,0/9,4<br />

+ 18 22 32 7,9/7,6 24 31 9,2/9,7<br />

+ 20 22 33 8,0/7,7 23 32 9,3/9,9<br />

+ 5 34 26 6,9/6,2 37 24 8,1/7,9<br />

Warm water pump<br />

90/70<br />

+ 15 29 33 7,2/6,7 32 31 8,5/8,6<br />

+ 18 28 35 7,4/6,8 30 33 8,6/8,8<br />

+ 20 27 36 7,4/7,0 29 35 8,7/8,9<br />

* Sound pressure:<br />

Approximate values at the distance of 5 m laterally from the unit, at maximum air volume flow and low reflection room.<br />

Industrial facility volume 1500 m³/h, absorbtion surface 200 m² Sabin, hemispherical radiation = radiation factor 2.<br />

Due to room/space features these values can be significantly influenced in terms of better or worse indicators.<br />

6 PR-2007-0527GB • Subject to modifications • Status 11/2007


<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

Unit Data<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> 32 (400 V~)<br />

Speed/RPM [min -1 ] 660 900<br />

Max. power consumption [kW] 0,20 0,31<br />

Max. current consumption [A] 0,50 0,88<br />

Sound pressure * [dB(A)] 55 61<br />

with profile discharge (wall or ceiling)<br />

Air volume flow [m 3 /h] 3680 4720<br />

Inlet/<br />

return temperature<br />

Warm water pump<br />

70/50<br />

Suction<br />

temp. [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 34 33 7,6/7,7 39 30 6,2/5,7<br />

+ 15 27 37 6,7/6,4 31 35 8,2/8,6<br />

+ 18 25 38 6,9/6,6 29 36 8,5/9,0<br />

+ 20 24 39 7,0/6,8 27 37 8,6/9,3<br />

+ 5 42 39 5,8/5,2 48 35 7,2/7,0<br />

Warm water pump<br />

80/60<br />

+ 15 35 43 6,2/5,6 40 40 7,6/7,6<br />

+ 18 33 45 6,3/5,8 38 42 7,8/7,9<br />

+ 20 31 45 6,4/5,9 36 43 7,9/8,1<br />

+ 5 49 45 5,5/4,8 57 41 6,8/6,4<br />

Warm water pump<br />

90/70<br />

+ 15 42 49 5,8/5,1 48 46 7,1/6,9<br />

+ 18 40 50 5,9/5,3 46 47 7,2/7,1<br />

+ 20 39 51 6,0/5,3 44 48 7,3/7,2<br />

with basic discharge wall/ceiling two sides<br />

Air volume flow [m 3 /h] 4150 5200<br />

Inlet/<br />

return temperature<br />

Warm water pump<br />

70/50<br />

Suction<br />

temp [°C]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

Heating capacity<br />

[kW]<br />

Discharge<br />

temp. [°C]<br />

Air throw/<br />

suspension<br />

height [m]<br />

+ 5 36 31 5,7/4,8 41 29 6,9/6,3<br />

+ 15 29 36 6,2/5,3 33 34 7,4/7,1<br />

+ 18 27 37 6,3/5,6 30 35 7,6/7,4<br />

+ 20 25 38 6,5/5,7 28 36 7,8/7,6<br />

+ 5 45 37 5,4/4,3 50 34 6,5/5,7<br />

Warm water pump<br />

80/60<br />

+ 15 37 42 5,7/4,7 42 39 6,9/6,3<br />

+ 18 35 43 5,8/4,9 40 41 7,0/6,5<br />

+ 20 33 44 5,9/5,0 38 42 7,1/6,6<br />

+ 5 53 43 5,1/4,0 59 39 6,1/5,3<br />

Warm water pump<br />

90/70<br />

+ 15 45 48 5,3/4,3 51 44 6,4/5,7<br />

+ 18 43 49 5,4/4,4 49 46 6,5/5,8<br />

+ 20 42 50 5,5/4,5 47 47 6,6/6,0<br />

* Sound pressure:<br />

Approximate values at the distance of 5 m laterally from the unit, at maximum air volume flow and low reflection room.<br />

Industrial facility volume 1500 m³/h, absorbtion surface 200 m² Sabin, hemispherical radiation = radiation factor 2.<br />

Due to room/space features these values can be significantly influenced in terms of better or worse indicators.<br />

PR-2007-0527GB • Subject to modifications • Status 11/2007 7


Unit Data<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

Suspension of type Compact C<br />

J<br />

Ø 16<br />

C<br />

D<br />

B<br />

Speed switch unit MC302<br />

Intermediate terminal box 981860<br />

Room thermostat 902005<br />

Industrial facility thermostat 902013<br />

Ø 10<br />

For circulating air units for wall and ceiling installation;<br />

galvanized sheet steel<br />

Type <strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>GEA</strong> <strong>MultiMAXX</strong> ®<br />

<strong>PROMPT</strong> 12 <strong>PROMPT</strong> 22 <strong>PROMPT</strong> 31/32<br />

Article-Nr. ZH1.5300 ZH2.5300 ZH3.5300<br />

B [mm] 340 392 504<br />

C [mm] 445 544 680<br />

D [mm] 40 40 50<br />

J [mm] 303 389 484<br />

X [mm] 340 392 504<br />

Weight [kg] 2,9 3,9 8,2<br />

– Plastic casing for wall mounting, light grey with<br />

separate room for connecting terminals<br />

– Protection type IP54<br />

– Contactor, switching capacity according to AC3 4 kW,<br />

max. current 9 A<br />

– Motor full protection electronics with automatic<br />

repeated start after power outage and blocking error<br />

switch off<br />

– Control lights for operational readiness and error<br />

– Connection terminals for room thermostat or external<br />

ON/OFF contact<br />

– Intermediate termial box for connecting a maximum of<br />

4 <strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> units<br />

– Plastic casing with room to insert cables for wall<br />

mounting<br />

– Protection type IP54<br />

– Row terminals 2,5mm²<br />

– Dimensions (W x H x D) 270 x 220 x 105 mm<br />

– Measument of room temperature<br />

with plastic casing<br />

– Protection type IP30<br />

– Setpoint range 5 ... 30 °C<br />

– Thermal return 230 V and 24 V<br />

– Switch over contact<br />

– Internal min. und max. setpoint scale fixing<br />

– Switching capacity at 250 V~<br />

– Heating contact 10(4) A<br />

– Cooling contact 5(2) A<br />

– Measument of room temperature with aluminium die<br />

cast / plastic casing and closed capillary system<br />

– Protection type IP54<br />

– Setpoint range/setpoint setting 0 … 35 °C<br />

– Sensor coil made of stainless steel (V4A) with<br />

protective basket<br />

– Switchning difference 0,5 … 1 K<br />

– Switch over contact 15 A ohm. 8 A ind. 250 V<br />

8 PR-2007-0527GB • Subject to modifications • Status 11/2007


<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

Dimensions and Weight<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong> with suspension<br />

K<br />

D<br />

C<br />

E<br />

G<br />

A<br />

Ø 16 mm<br />

F<br />

J<br />

B<br />

X<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ®<br />

<strong>PROMPT</strong> 12 <strong>PROMPT</strong> 22 <strong>PROMPT</strong> 31 <strong>PROMPT</strong> 32<br />

Unit<br />

Width A [mm] 642 738 866 866<br />

Height B [mm] 520 616 744 904<br />

Depth C [mm] 492 492 492 492<br />

Connection dimensions<br />

Fan casing/HE connector D [mm] 273 273 273 273<br />

Distance of HE connections E [mm] 75 75 75 75<br />

Distance of HE connections F [mm] 457 553 681 681<br />

Water content of heat exchanger [l] 1,7 2,4 1,8 3,5<br />

Nominal connection width of heat<br />

exchanger G1" G1" G1¼" G1¼"<br />

Discharges<br />

Profile discharge G [mm] 100 100 100 100<br />

Wall basic discharge G [mm] 105 105 105 105<br />

Ceiling basic discharge two sides G [mm] 105 105 105 105<br />

Suspension<br />

Compact C ZH1.5300 ZH2.5300 ZH3.5300 ZH3.5300<br />

Hole spacing width X [mm] 340 392 504 504<br />

Hole spacing height J [mm] 303 389 484 484<br />

Wall distance K [mm] 282 334 446 446<br />

Weights (unit+discharge)<br />

Profile discharge approx. [kg] 30 39 52 55<br />

PR-2007-0527GB • Subject to modifications • Status 11/2007 9


Notes<br />

<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

10 PR-2007-0527GB • Subject to modifications • Status 11/2007


<strong>GEA</strong> <strong>MultiMAXX</strong> ® <strong>PROMPT</strong><br />

Notes<br />

PR-2007-0527GB • Subject to modifications • Status 11/2007 11


Our Market in Europe<br />

A<br />

B<br />

BG<br />

BIH<br />

BY<br />

CH<br />

CZ<br />

D<br />

<strong>GEA</strong><br />

Klimatechnik GmbH<br />

A-4673 Gaspoltshofen<br />

Tel. +43 / 7735 / 8000-0<br />

<strong>GEA</strong> Happel Belgium N.V.<br />

B-1130 Brussels<br />

Tel. +32 / 2 / 2406161<br />

EVISS Ltd.<br />

BG-7000 Rousse<br />

Tel. +359 / 82 / 81000<br />

<strong>GEA</strong> Klimatehnika<br />

RS-11070 Novi Beograd<br />

Tel. +381 / 11 / 3193955<br />

<strong>GEA</strong> Klimatechnik UAB<br />

LT-01141 Vilnius<br />

Tel. +370 / 5 / 2106060<br />

<strong>GEA</strong> Klimatec<br />

Schweiz AG<br />

CH-3065 Bolligen-Station<br />

Tel. +41 / 31 / 9171919<br />

<strong>GEA</strong> LVZ, a.s.<br />

CZ-46312 Liberec<br />

Tel. +420 / 48 / 5225-111<br />

<strong>GEA</strong> Klimatizace spol. s r.o.<br />

CZ-46312 Liberec<br />

Tel. +420 / 48 / 5225-303<br />

<strong>GEA</strong> Happel<br />

Klimatechnik GmbH<br />

D-44625 Herne<br />

Tel. +49 / 2325 / 468-00<br />

DK<br />

E<br />

EST<br />

F<br />

FIN<br />

GB<br />

H<br />

HR<br />

IE<br />

<strong>GEA</strong> Klimateknik ApS<br />

DK-2610 Rødovre<br />

Tel. +45 / 38 / 887070<br />

<strong>GEA</strong> Air Treatment<br />

Marketing Services<br />

Int. GmbH - oficina España<br />

E-28036 Madrid<br />

Tel. +34 / 91 / 3837701<br />

<strong>GEA</strong> Klimatechnik UAB<br />

LT-01141 Vilnius<br />

Tel. +370 / 5 / 2106060<br />

<strong>GEA</strong> Happel France sarl<br />

F-59436 Roncq Cedex<br />

Tel. +33 / 3 / 20689020<br />

OY TEKNOCALOR AB<br />

FIN-01300 Vantaa<br />

Tel. + 358 / 9 / 82546020<br />

Denco Ltd.<br />

UK-HR4 8DS Hereford<br />

Tel. +44 / 1432 / 277 277<br />

<strong>GEA</strong> Klimatechnika Kft<br />

H-1037 Budapest<br />

Tel. +36 / 1 / 4393200<br />

<strong>GEA</strong> Klima-rashladna<br />

tehnika d.o.o.<br />

HR-10000 Zagreb<br />

Tel. +385 / 1 / 6064900<br />

Aspect Environmental Ltd.<br />

Ardee, Co. Louth<br />

Ireland<br />

Tel. +353 / 41 / 6858983<br />

IS<br />

L<br />

LT<br />

LV<br />

MWE<br />

N<br />

NL<br />

P<br />

PL<br />

Rafn Jensson<br />

IS-110 Reykjavik<br />

Tel. +354 / 56 / 780-30<br />

<strong>GEA</strong> Happel Luxembourg<br />

L-4940 Bascharage<br />

Tel. +352 / 26 / 502970<br />

<strong>GEA</strong> Klimatechnik UAB<br />

LT-01141 Vilnius<br />

Tel. +370 / 5 / 2106060<br />

<strong>GEA</strong> Klimatechnik UAB<br />

LT-01141 Vilnius<br />

Tel. +370 / 5 / 2106060<br />

<strong>GEA</strong> Klimatehnika<br />

RS-11070 Novi Beograd<br />

Tel. +381 / 11 / 3193955<br />

<strong>GEA</strong> Klimaprodukter AS<br />

N-0484 Oslo<br />

Tel. +47 / 220 / 27990<br />

<strong>GEA</strong> Happel<br />

Nederland B.V.<br />

NL-2909 LL<br />

Capelle a/d Ijssel<br />

Tel. +31 / 10 / 2350606<br />

Nónio, Lda.<br />

P-1269-090 Lisboa<br />

Tel. +351 / 21 / 3826160<br />

<strong>GEA</strong><br />

Klimatyzacja Sp. z o.o.<br />

PL-54610 Wroclaw<br />

Tel. +48 / 71 / 3737952<br />

RO<br />

RUS<br />

S<br />

SK<br />

SLO<br />

SRB<br />

TR<br />

UA<br />

<strong>GEA</strong> Klimatechnik s.r.l.<br />

RO-300222 Timisoara<br />

Tel. +40 / 356 / 423703<br />

<strong>GEA</strong> Kondicioner<br />

Moskva<br />

RU-105094 Moskva<br />

Tel. +7 / 495 / 9566674<br />

<strong>GEA</strong> EXOS<br />

Ventilation AB<br />

S-74528 Enköping<br />

Tel. +46 / 171 / 85530<br />

<strong>GEA</strong> Klimatizácia s.r.o.<br />

SK-83104 Bratislava<br />

Tel. +421 / 7 / 44457917<br />

<strong>GEA</strong> Klimatizacijska<br />

Tehnika d.o.o.<br />

SI-1000 Ljubljana<br />

Tel. +386 / 1 / 2573850<br />

<strong>GEA</strong> Klimatehnika<br />

RS-11070 Novi Beograd<br />

Tel. +381 / 11 / 3193955<br />

ISISAN<br />

TR-80700 Balmumcu<br />

Istanbul<br />

Tel. +90 / 212 / 2757171<br />

<strong>GEA</strong> Ukraina t.o.v.<br />

UA-01135 Kyiv<br />

Tel. +38 / 044 / 4619356<br />

PR-2007-0527GB • Subject to modifications • Status 11/2007 • Copyright <strong>GEA</strong> Air Treatment<br />

Air Treatment Division<br />

A <strong>com</strong>pany of <strong>GEA</strong> Group<br />

For detailed information on all corporate areas,<br />

go to www.gea-airtreatment.<strong>com</strong> or contact<br />

us by email info@gea-airtreatment.<strong>com</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!