20MB - M-System
20MB - M-System
20MB - M-System
Transform your PDFs into Flipbooks and boost your revenue!
Leverage SEO-optimized Flipbooks, powerful backlinks, and multimedia content to professionally showcase your products and significantly increase your reach.
Total Components<br />
PC / DCS / PLC<br />
M-<strong>System</strong> offers a wide range of instrumentation/<br />
automation components used for process,<br />
factory and building automation, from the field<br />
level up to the control room level.<br />
We are your supply partner for the interfacing<br />
applications of analog/discrete signals,<br />
communication networks and intelligence<br />
systems.<br />
Supplier for PA / FA / BA<br />
Process<br />
Factory<br />
Building<br />
Automation<br />
Automation<br />
Automation<br />
M-<strong>System</strong> Has Not Discontinued its Products<br />
Without Compatible Replacements.<br />
We do not easily stop manufacturing products once released in the market,<br />
without trying to supply compatible products of equal or better performance<br />
to replace with, because we believe it is an important responsibility as the<br />
world’s leading manufacturer to continue serving people who maintain the<br />
performance of process control systems.<br />
Visit M-<strong>System</strong> web site and find specifications and instruction manuals no<br />
matter how old the product, downloadable at our online DATA LIBRARY,<br />
updated weekly.<br />
◆ Supplying ready-to-install products in fast & precise delivery time<br />
Paperless Recorders<br />
Indicators<br />
Multi Function<br />
PID Controllers<br />
Manual Loading<br />
Stations<br />
Control Room<br />
The standard manufacturing lead time for most M-<strong>System</strong> products with<br />
customer’s specified range is 5 days. But more than quarter of the total<br />
shipments are delivered in shorter lead time, and Quick Service Center<br />
expedites more than 500 orders every month on the same day or the next<br />
day after ordered.<br />
So do not worry too much about the standard delivery. Just let us know<br />
‘When’ you need one of our products, calibrated for your exact needs.<br />
Once a delivery time is promised, you can of course count on us to deliver<br />
them precisely on time.<br />
Loop<br />
Powered<br />
Indicators<br />
Two-wire<br />
Signal<br />
Conditioners<br />
Four-wire Signal Conditioners<br />
Limit Alarms<br />
Power Transducers<br />
Lightning Surge Protectors<br />
For Electronic Equipment<br />
<br />
Sensors / Transmitters<br />
Remote I/O<br />
LONWORKS<br />
Electric<br />
Actuators<br />
Electric<br />
Control Valves<br />
Pneumatic<br />
Transducers<br />
Valve Positioners<br />
Position Sensors<br />
Pneumatic<br />
Control Valves<br />
Final Control Elements<br />
Motors<br />
Field<br />
◆ Striving toward complete offerings with special specification products<br />
We offer an enormous selection of signal conditioners and remote I/Os, energy monitors, paperless recorders,<br />
panel meters, surge suppressors and valve actuators, and even that may not be enough for your particular needs.<br />
But do not give up easily. Just ask us. We continue to work toward full product offerings with special products<br />
designs. In addition, we put our effort to make them into standard selections so that they are more easily accessible<br />
to you and everyone else in the future.<br />
◆ Meeting quickly for modern need for EMC countermeasures<br />
Advances in technologies have led to higher-density electronic circuits, higher-frequency signals, and lower circuit<br />
voltages in most electronic devices, making them more susceptible to the effects of weak EMI.<br />
EMC countermeasures combining EMI and EMS components provide the basic means of dealing with electromagnetic<br />
radiation. These countermeasures must be incorporated from the product design and development stage.<br />
Increasingly strict standards defining the levels of EMI that are permissible from a safety standpoint have also<br />
served to focus attention on the importance<br />
of EMC countermeasures.<br />
Many equipment manufacturers rely<br />
upon public testing facilities to verify the<br />
compliance of their products with<br />
Europe’s mandatory CE marking program.<br />
M-<strong>System</strong> has its own RF anechoic chamber<br />
and shielded room facilities, Kyoto Techno<br />
Center, in order to speed the development<br />
of new products.<br />
M-<strong>System</strong> Kyoto Techno Center<br />
RF Anechoic Chamber<br />
M-001 Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp<br />
ISP ’12<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
M-002
003M<br />
M-<strong>System</strong> Website M-<strong>System</strong> Website<br />
Visit www.m-system.co.jp for more<br />
M 004<br />
information about M-<strong>System</strong> products!<br />
M-<strong>System</strong>’s Global Home Page<br />
CLICK<br />
www.m-system.co.jp DATA LIBRARY<br />
Select Your Language<br />
■■<br />
Japanese<br />
■■<br />
English<br />
■■<br />
Simplified Chinese<br />
■■<br />
Traditional Chinese<br />
■■<br />
Korean<br />
WORLD SALES CONTACTS<br />
M-<strong>System</strong> has a worldwide network of sales representatives.<br />
Access WORLD SALES CONTACTS to find M-<strong>System</strong>’s local<br />
representative in your area.<br />
Find specifications, instruction manuals and ordering<br />
information sheet no matter how old the product,<br />
downloadable at our DATA LIBRARY, updated weekly.<br />
3<br />
2<br />
1<br />
PRODUCTS SEARCH<br />
You can search M-<strong>System</strong> products<br />
by keywords and model no.<br />
Search by keywords<br />
It searches keywords in specification<br />
sheets and shows relevant products.<br />
Once specific products are selected,<br />
you can compare their specifications<br />
by html style.<br />
1<br />
Search By Product<br />
Name and Function<br />
Series Index lists the product<br />
categories or series names of<br />
signal conditioners and other<br />
products.<br />
2 CE &<br />
Agency Approval<br />
For searching products with CE,<br />
UL/C-UL or hazardous location<br />
approvals.<br />
3<br />
Search By<br />
Model No.<br />
If you already know Model No.<br />
of the product you need, use<br />
our Model No. index.<br />
CLICK<br />
CLICK<br />
CLICK<br />
PRODUCT CATEGORIES<br />
Information on most popular M-<strong>System</strong> products is included and<br />
updated continuously on our web site. For more information on the<br />
products in this catalog including detailed data sheet, look into the<br />
product categories.<br />
SERVICES & SUPPORT<br />
Technical and application information is available in<br />
SERVICES & SUPPORT section.<br />
Device profiles and updates of configurator software,<br />
demo version tryouts are downloadable.<br />
CLICK<br />
M-003<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.<br />
ISP ’12 M-004
M<br />
Signal Conditioners<br />
005 PRODUCTS CATEGORY<br />
A<br />
Signal Conditioners<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
Converting a field signal suitable for processing after conditioning<br />
Power Transducers<br />
Two-wire Signal Conditioners<br />
P.001 a P.250 P.251 a P.296<br />
Measuring most electrical parameters<br />
A<br />
C<br />
High performance transmitters in various housing styles<br />
Indicators<br />
Bright, Clear, and Colorful Displays<br />
B<br />
D<br />
P.297 a P.336<br />
Limit Alarms<br />
Monitoring a process signal and providing limit alarm trips<br />
E<br />
Gateway, Remote I/O<br />
P.337 a P.422<br />
Communicating directly to the PLC, DCS, HMI<br />
F<br />
P.423 a P.428<br />
P.429 a P.436<br />
Paperless Recording <strong>System</strong><br />
Versatile data recording and intuitive operation<br />
G<br />
PC Recorder<br />
H<br />
Log, Trend, Analyze and Profile Process Signals with your PC<br />
P.437 a P.442<br />
P.443 a P.450<br />
Electric Actuators & Position Sensors<br />
High resolution positioning for superior valve control<br />
i<br />
Lightning Surge Protectors<br />
Protecting sensor, signal, power and communication lines<br />
J<br />
P.451 a P.456<br />
P.457 a P.473<br />
M-005<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
A<br />
Signal Conditioners P.001<br />
l Product Selection Guide P.002<br />
l Mini-M Series (M2) P.008<br />
l Mini-MW Series (W2) P.106<br />
l M6 Series P.138<br />
l M5-UNIT Series P.184<br />
l W5-UNIT Series P.202<br />
SERIES INDEX M 006<br />
l 38-RACK Series P.249<br />
l Others<br />
(model: MDC5/MDC6/MDC7 )<br />
Two-wire<br />
Signal Conditioners<br />
B<br />
P.249<br />
P.251<br />
l Product Selection Guide P.252<br />
l 27-UNIT Series P.254<br />
l 26-UNIT Series P.266<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
l M3-UNIT Series P.214<br />
l B6-UNIT Series P.272<br />
l M3S-UNIT Series P.234<br />
l B3-UNIT Series P.278<br />
l 20 Series P.246<br />
l B5-UNIT Series P.290<br />
l Pico-M Series (M8) P.248<br />
l 6-UNIT Series P.296<br />
l MX-UNIT Series P.248<br />
l T-UNIT Series P.296<br />
l M-UNIT Series P.248<br />
l B-UNIT Series P.296<br />
l W-UNIT Series P.248<br />
l K-UNIT Series P.248<br />
l F-UNIT Series P.248<br />
l H-UNIT Series P.249<br />
l 10-RACK Series P.249<br />
l 18-RACK Series P.249<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-006
007M<br />
Signal Conditioners<br />
A<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
SERIES INDEX<br />
C<br />
Power Transducers P.297<br />
l Product Selection Guide P.298<br />
l LT-UNIT Series P.300<br />
l 54-UNIT Series/ 53U/ 52U/ 51U P.328<br />
l L- UNIT Series P.334<br />
l LSMT4 P.334<br />
l K-UNIT Series P.334<br />
E<br />
Limit Alarms P.423<br />
l Product Selection Guide P.424<br />
F<br />
Gateway, Remote I/O P.429<br />
l Product Selection Guide P.430<br />
l R6 Series P.432<br />
l CLS Series P.335<br />
l R7 Series P.433<br />
D<br />
Indicators P.337<br />
l Product Selection Guide P.338<br />
l R3 Series P.434<br />
l R5 Series P.434<br />
l R1 Series P.432<br />
l Bargraph Indicators P.342<br />
l 60-UNIT Series P.436<br />
l Digital Panel Meters P.372<br />
l 61-UNIT Series P.436<br />
l 6DV Series P.412<br />
l M2BC / M2BD P.436<br />
l 43 Series P.418<br />
l D3 Series P.436<br />
l DLA Series P.436<br />
M-007<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Paperless Recording<br />
<strong>System</strong><br />
G<br />
P.437<br />
l 73VR Series P.438<br />
l 73VR3100 P.439<br />
l 73VR2100 P.440<br />
l 73VR1100 P.441<br />
l 71VR1 P.442<br />
H<br />
PC Recorder P.443<br />
l PC Recorder Series P.444<br />
Lightning Surge<br />
Protectors<br />
SERIES INDEX M 008<br />
J<br />
P.457<br />
l Lightning Surge Protectors M-RESTER P.458<br />
l Standard Signal Line & Pulse Use P.462<br />
l Sensor Use P.465<br />
l Transmission Line Use P.468<br />
l Power Supply Use P.471<br />
l DC Power Supply Use P.472<br />
l One-port Surge Protector P.473<br />
l Accessories P.473<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
l MSRPAC P.446<br />
l MSRpro P.448<br />
l I/O Modules P.450<br />
Electric Actuators<br />
& Position Sensors<br />
P.451<br />
l Electric Actuators P.452<br />
i<br />
l Position Sensors P.456<br />
l Valve Positioners P.456<br />
l Control Backups P.456<br />
Model Number Index Z-1<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-008
009M<br />
Signal Conditioners<br />
A<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
FEATURED PRODUCTS<br />
Fully Programmable Multi-Function PID Controller<br />
NEW<br />
Highly visible color graphic LCD<br />
Intuitive touch panel operation<br />
72 x 144 mm DIN format standard panel size<br />
2 x universal inputs, 4 x analog inputs, 5 x contact or pulse inputs,<br />
1 x high speed pulse input<br />
2 x 4-20 mA outputs, 2 x 1-5 V outputs, 6 x contact outputs<br />
Two loops of PID control<br />
Advanced computation and sequential control functions<br />
Automatic PID parameter setting by ‘Auto-Tuning’ function<br />
Modbus TCP/IP or RTU communication SC200 SC210<br />
NestBus (RS-485) peer-to-peer communication SC200 SC210<br />
Built-in manual loader SC110 SC210<br />
SC Series Controllers<br />
Auxiliary Control Panel Instruments<br />
SC100: Basic version<br />
SC200: Modbus / NestBus<br />
extension version<br />
SC110: Basic version with manual loader<br />
SC210: Modbus / NestBus extension version<br />
with manual loader<br />
SD10: 3-channel Bargraph Indicating Alarm<br />
SM10: Manual Loader<br />
M-009<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
DCS in Instrument Format<br />
– Advanced Computation and Sequential Control Functions<br />
FEATURED PRODUCTS M 010<br />
The control and computation functions are achieved by combining a wide variety of basic to advanced function<br />
blocks, which are normally found only in DCS systems. 2 PID blocks, 48 computation blocks and 12 sequential<br />
control blocks (1068 commands) are available for all versions of the SC Series, applicable to a wide range of<br />
application fields.<br />
NestBus<br />
SC200/SC210<br />
Function Block Structure<br />
Control Blocks<br />
• Basic PID<br />
• Advanced PID<br />
• Manual loader<br />
• Ratio setter<br />
Operations Blocks<br />
• Pulse adder<br />
• Pulse accumulator<br />
• Arithmetic function<br />
• Non-linear gain, deadband<br />
• Temp/press compensation<br />
• First order lag<br />
• Moving average<br />
• Dead time compensation<br />
2 Blocks<br />
• Indicator<br />
32 Blocks<br />
• Max/Min value selector<br />
• Hi/Lo alarm<br />
• Deviation alarm<br />
• Sequence control<br />
• Timer<br />
• Counter<br />
:<br />
:<br />
NestBus Terminal<br />
Communication Blocks<br />
Sequential Control Commands Blocks<br />
Large Operation Blocks<br />
• Linearizer<br />
• Ramp program<br />
Batch program<br />
Field Terminal Blocks<br />
8 Blocks<br />
16 Blocks<br />
8 Blocks<br />
12 Blocks<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Field I/O Terminal<br />
Analog I/O<br />
Discrete I/O<br />
Excellent Expandability with Peer-to-peer and Host Communication<br />
The SC200/SC210 has Modbus<br />
(Ethernet TCP/IP or RS-485 RTU) which<br />
enables easy connection to logging or<br />
SCADA systems on a host PC for<br />
supervising and controlling the local<br />
I/O data. In addition, the RS-485<br />
‘NestBus’ enables peer-to-peer<br />
communication with other controllers<br />
and I/O devices for flexibility of I/O<br />
points.<br />
Expanded <strong>System</strong> Configuration Example<br />
Host Communication<br />
Peer-to-peer<br />
Modbus/TCPEthernet<br />
or Modbus RTU<br />
SC200<br />
NestBus<br />
SCADA<br />
SC200<br />
PC<br />
SC210<br />
SC210<br />
SC200<br />
SC200<br />
I/O Module<br />
model: SML<br />
High Reliability for Demanding Process Use<br />
Control, display and I/O functions are managed by<br />
independent CPUs for enhanced security and reliability.<br />
The built-in manual loader (option) can be controlled<br />
independently even in case of a failure of the main<br />
controller module, which can be replaced easily while<br />
the backup control is maintained. The loader module<br />
can be powered independently from that of the main<br />
module for further reliability.<br />
Main module extracted for<br />
repair with MV maintained.<br />
Five LEDs indicate MV when<br />
LCD display is failed.<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-010
011M<br />
Signal Conditioners<br />
A<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
FEATURED PRODUCTS<br />
Signal Conditioners<br />
Compact Plug-in – M2 / W2 Series<br />
Widest selection of I/O type/ranges and functions<br />
Signal splitters<br />
Quick maintenance without disturbing base wiring<br />
Base socket included with the modules<br />
M2: 74 models W2: 25 models<br />
Field Mount – 26 / 27 / B6 Series<br />
HART or PC programmable sensor type<br />
and temperature range<br />
Display module can be combined<br />
ATEX / FM approval<br />
More Than 1100 Models to Choose From !<br />
Low Profile – M5 / W5 / B5 Series<br />
Only 41 mm (1.61 in) deep, terminal block style housing<br />
Installable even in wall-mounted shallow control panels<br />
Signal splitters and 2-wire transmitters also available<br />
Cost effective<br />
Thin Profile – M3 / M3S / B3 Series<br />
Separable terminal block for easy maintenance<br />
Signal splitters and 2-wire transmitters also available<br />
Dual Output in Super-mini Modules<br />
– M8 Series<br />
Direct interface to various DCS via the rack<br />
side connector<br />
Various User Programming Styles<br />
Easy Setpoint Adj. for Limit Alarms<br />
One-Step-Cal setting<br />
DIP switch setting<br />
Control buttons with display<br />
M3L M2L Series<br />
Auto configuration by buttons<br />
M2FV<br />
W5FV<br />
B3F<br />
Series<br />
DIP switch<br />
AS4<br />
M7E<br />
Series<br />
Simulator<br />
Multimeter<br />
IN<br />
OUT<br />
PC software setting<br />
M3 M2 M6 Series<br />
DOWNLOAD<br />
UPLOAD<br />
PC<br />
Control buttons with display<br />
MX Series<br />
LEDs<br />
Control buttons<br />
Thumbwheel switches<br />
M2<br />
ASD1<br />
KSED<br />
AE<br />
Series<br />
PC software<br />
M6<br />
Series<br />
M-011<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
NEW<br />
Miniature Isolation Amplifiers 20 Series<br />
Isolation amplifiers provide signal and power isolation for data<br />
acquisition components to protect them from noises present at<br />
remote devices.<br />
Also useful to:<br />
Amplify low-level signals in multi-channel applications<br />
plications<br />
Eliminate measurement errors by ground loops<br />
Reduce circuit costs<br />
M-<strong>System</strong> offers a complete range of isolation amplifiers featuring:<br />
FEATURED PRODUCTS M 012<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
• Input isolation (two-port)<br />
• Output isolation (two-port)<br />
• Three-port isolation<br />
• Low-level mV signal input<br />
• DC current output<br />
• High isolation voltage<br />
• Wide bandwidth<br />
• Powered by external clock<br />
• High gain<br />
Ultra-slim Signal Conditioners M6 Series<br />
Selectable connection styles: tension clamp, screw terminal or euro terminal<br />
Wide selection of functions: DC, temperature, pulse, CT, 2-ch loop powered isolator,<br />
limit alarm and function modules<br />
8-module base saves you from individual power input wiring, expandable up to<br />
six bus-connected bases (48 modules).<br />
Only 9.5 cm (3.75 in) with 16 modules, less than 30 cm (12 in) with 48 modules (M6S/M6D)<br />
2000 Vac isolation<br />
72 modules in 19 inch rack space*<br />
* Including 2 power supply modules<br />
* For M6S/M6D series only<br />
* DIN rail mounting without using installation base<br />
5.9 mm (0.23 in.)<br />
5.9 mm (0.23 in.)<br />
7.5 mm (0.30 in.)<br />
Tension Clamp<br />
Euro Terminal<br />
Screw Terminal<br />
M6S Series<br />
M6D Series<br />
M6N Series<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-012
013M<br />
Signal Conditioners<br />
A<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
FEATURED PRODUCTS<br />
High-Precision, Ultra-High Speed Response Isolator<br />
Compact plug-in type: M2VF3<br />
Accuracy: ±0.01%<br />
Response: ≤30 µs (0-90%)<br />
Freq. characteristics:<br />
12 kHz, -3 dB<br />
Hybrid IC type: 20VF<br />
Linearity: ±0.05%<br />
Response: ≤80 µs (0-90%)<br />
Freq. characteristics:<br />
Approx. 5 kHz, -3 dB<br />
Ultra-slim type: M6xVF<br />
Accuracy: ±0.01%<br />
Response: ≤30 µs (0-90%)<br />
Freq. characteristics:<br />
12 kHz, -3 dB<br />
Application example: Battery Test <strong>System</strong><br />
The battery test system is used for evaluating advanced batteries or capacitors in hybrid vehicles.<br />
The main feature of system is to conduct charging and discharging tests for batteries.<br />
Battery Pack<br />
Electric Motor<br />
Battery Controller<br />
Benefits of using M-<strong>System</strong> signal isolator to<br />
meet required A/D conversion criteria:<br />
• High precision (linearity and low temperature drift)<br />
• Ultra fast response time<br />
• Dielectric strength for high frequency noise<br />
• Low power consumption<br />
• Variety of form factors available (Surface mount, Ultra-slim,<br />
shallow depth, etc.) to maximize space constraints<br />
Performance data of M2VF3:<br />
• Wide input DC voltage range is available to specify from min. -20 to +20 mV up to -800 to +800 V<br />
• High accuracy: ±0.01%, Temp. coefficient: ±0.005%/˚C, in percentage of span<br />
• Ultra-high speed response: ≤30 µs (0-90%)<br />
Data sample<br />
Accuracy (%)<br />
Linearity data graph<br />
Actual test data<br />
Approx. 0.005%<br />
Accuracy: ±0.01%<br />
in percentage of span<br />
Input (%)<br />
Temperature coefficient (ppm/˚C)<br />
in percentage of span<br />
Data sample<br />
Temperature drift data graph<br />
Approx. 17 ppm<br />
Ambient temperature (˚C)<br />
Data sample<br />
Step input<br />
100%<br />
90%<br />
Output<br />
Ultra-high speed response<br />
30 µsec.<br />
(Approx. 20 µsec.)<br />
The above data is for M2VF3<br />
M-013<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
FEATURED PRODUCTS M 014<br />
Scalable Remote I/O with Wide I/O and Network Selections<br />
NEW<br />
Low Profile, Compact I/O – R7F4DH Series<br />
Tension-clamp terminal, e-CON connector and MIL connector styles now added<br />
to the R7 Series Compact Remote I/O.<br />
R3 Series<br />
Tension-clamp terminal<br />
e-CON connector<br />
Widest selection of network and I/O (DC/AC,<br />
temperature, pulse, strain gauge and energy)<br />
4 isolated up to 16 non-isolated analog points per<br />
module<br />
16, 32 or 64 discrete points per module<br />
Dual redundant network and power supply<br />
R7 Series<br />
MIL connector<br />
Palm-top size housing with mixed analog/discrete<br />
signal capability<br />
4 isolated analog inputs or 2 isolated analog outputs,<br />
16-point discrete I/O<br />
8 or 16-point discrete module can be added<br />
Simple and economical solution for applications with<br />
a few analog/discrete mixed signals<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
LONWORKS<br />
R5 Series<br />
1 or 2 isolated analog points per<br />
module<br />
Dual redundant network and power<br />
supply<br />
R6 Series<br />
Ultra-slim I/O modules<br />
2 isolated analog points per module<br />
Simple I/O expansion<br />
R1 Series<br />
All-in-one package for 8 to<br />
16-point analog inputs<br />
32-point discrete I/O<br />
Ideal for small scale temperature<br />
scanning applications<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-014
015M<br />
Signal Conditioners<br />
A<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
FEATURED PRODUCTS<br />
Power/Energy Monitors for Various Open Networks<br />
Single-phase 2-wire and 3-wire, three-phase 3-wire and 4-wire systems<br />
IP 52 front panel<br />
Various network communication and Ao/Do combinations selectable<br />
Up to 31st harmonic distortion measurement<br />
Software lock<br />
L53U<br />
DIN rail mounted<br />
53U<br />
96-mm square panel size<br />
54U / 54UC / 54UL<br />
110-mm square panel size<br />
• Modbus + Di/Do<br />
• Ao x 4 points<br />
• Modbus + Di/Do<br />
• Ao x 2 points + Di/Do<br />
• Ao x 4 points<br />
• Ao x 4 points<br />
• Di/Do<br />
LONWORKS<br />
Monitoring and Storing<br />
Measured/Computed Values on the PC<br />
The PC Recorder Light MSR128LU dedicated<br />
for energy monitors is free for downloading<br />
from our web site.<br />
Modbus RS-485<br />
RS-232C/RS-485 Converter<br />
R2K-1<br />
53U<br />
54U<br />
L53U<br />
NEW NEW NEW<br />
LSMT4<br />
R7MWTU, R7EWTU, R7CWTU, R7LWTU R9MWTU, R9EWTU, R9CWTU, R9LWTU<br />
• 10 analog outputs<br />
• 2 Wh pulse outputs<br />
• Clamp-on current sensor use:<br />
easy installation<br />
• 2 systems input<br />
• Clamp-on current sensor use:<br />
easy installation<br />
• Up to 8 systems input<br />
• Time stamped data logging in SD card<br />
LONWORKS<br />
LONWORKS<br />
M-015<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Energy Consumption Monitoring <strong>System</strong><br />
Minimum down time for installation of clamp-on current sensors;<br />
CT installation or rewiring is not required<br />
Existing office LAN can be used*<br />
Field LAN<br />
Office LAN<br />
Current<br />
Totalized pulse<br />
Mixed Signal Remote I/O<br />
R3 Series<br />
FEATURED PRODUCTS M 016<br />
Modbus RS-485<br />
Server<br />
Client<br />
Ethernet<br />
Ethernet<br />
72EM2-M4<br />
Ethernet<br />
Communication<br />
Adaptor<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Energy meter<br />
53U Multi Power Monitor<br />
Easy-to-Install Current Sensor<br />
I/O via Ethernet Network<br />
✔ Easy installation<br />
✔ Wide selections<br />
Clamp-on current sensors are easy to install compared to<br />
current transformers (CT) which usually need extra<br />
modifications for the power distribution panel.<br />
Clamp-on Current Sensor<br />
CLS Series<br />
PC Recorder Software<br />
MSRpro and PC Recorder<br />
are user-friendly<br />
monitoring and recording<br />
software programs.<br />
With remote I/O installed in an unused space inside<br />
the power distribution panel, data can be collected<br />
effectively via the field LAN.<br />
✔ Existing office LAN can be used.*<br />
✔ Wide range of mixed sensor signals can be<br />
monitored.<br />
✔ Economical solution by choosing only<br />
necessary I/O function modules.<br />
Power Monitoring Modules from R3 Series<br />
• AC current input module<br />
• Zero-phase current (ZCT) input module<br />
• AC voltage input module<br />
• AC power input module<br />
• Totalized pulse input module<br />
Temperature, DC and other sensor signal inputs are<br />
also available.<br />
*Use of dedicated field LAN for the remote I/O is recommended.<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-016
017M<br />
Signal Conditioners<br />
A<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
FEATURED PRODUCTS<br />
Bright, Clear & Colorful Digital Panel Meters<br />
Variety of Direct Sensor Input – 47L Series<br />
• IP 66 front panel<br />
• Separable terminal block<br />
• 4, 4 1/2 or 6 digits LED<br />
• 6 LED colors selectable<br />
• DC/AC, temperature, potentiometer, strain gauge and pulse input<br />
• DC output and alarm output optional<br />
Six LED Colors – 47L Series<br />
Red Blue<br />
Orange Bluegreen<br />
White<br />
External Interface Output – 47D Series<br />
• IP 66 front panel<br />
• Separable terminal block<br />
• 5 1/2 digit LCD<br />
• Bargraph and sub display<br />
• DC output, alarm output, Modbus and BCD output optional<br />
Green<br />
12 models<br />
LED<br />
4 or 4 1/2 or<br />
6 digits<br />
IP 66<br />
5 models<br />
LCD<br />
5 1/2 digits<br />
IP 66<br />
Large 0.8” High LED – 40 Series<br />
• 0.8” (20.3 mm) high red LED<br />
• 3 1/2 or 4 digits<br />
• DC voltmeter/ammeter or process meter<br />
• Direct temperature input also available<br />
• Display hold function<br />
3 models<br />
LED<br />
3 1/2 or 4 digits<br />
1/32 DIN Size – 43DV2<br />
• 48 x 24 mm panel size<br />
• Easy-to-wire tension clamp connection<br />
• Process scaling<br />
Line Powered<br />
LED<br />
4 digits<br />
LED<br />
1/32 DIN Size – 43AL1<br />
Loop Powered<br />
• 48 x 24 mm panel size<br />
• Powered from a 4-20 mA current loop<br />
• No external power supply needed<br />
• Easy-to-wire tension clamp connection<br />
• Process scaling<br />
LED<br />
4 digits<br />
Field Indicator – 6DV / 6DV-B<br />
• Powered from a 4-20 mA current loop<br />
• No external power supply needed<br />
• Scaling & linearization selectable via<br />
the front control buttons<br />
• IP 66/67 field enclosure, aluminium or<br />
stainless steel<br />
• ATEX / FM approval<br />
LED<br />
4 digits<br />
IP 66/67<br />
6DV<br />
6DV-B<br />
M-017<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
101-segment Bargraph Indicators<br />
NEW<br />
SD10<br />
101-segment, 3 mm wide LED with wide viewing angle<br />
3 channels housed in single package<br />
Red, amber, green and blue colors<br />
4-digit digital indication selectable with the front control<br />
Easily replaceable scale plate<br />
Custom scale with no extra cost<br />
Each input is provided with 4 alarm outputs;<br />
DC output optional<br />
Excitation supply for two-wire transmitter<br />
IP 55 front panel<br />
FEATURED PRODUCTS M 018<br />
LED 4 digits IP 55<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
48N Series<br />
• 101-segment, 3 mm wide LED with wide viewing angle<br />
• Red, amber, green and blue colors<br />
• Easily replaceable scale plate<br />
• Custom scale with no extra cost<br />
• IP 65 front panel<br />
• Separable terminal block<br />
• 2 channel type selectable for 48NV<br />
• Alarm output<br />
• Direct sensor input, two-wire transmitter input type available<br />
LED IP 65<br />
Easily Replaceable Scaleplate<br />
48N Series<br />
6 models 6 models<br />
48NV 48NA Series 48ND Series<br />
51-segment Bargraph 48SV<br />
51-segment Bargraph 49AV2<br />
• Small size<br />
• Dimensions:<br />
W18 × H72 × D118 mm<br />
(0.71" × 2.83" × 4.65")<br />
LED<br />
• Alarm output<br />
• Dimensions:<br />
W96 × H96 × D116 mm<br />
(3.78" × 3.78" × 4.61")<br />
LED<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-018
019M<br />
Signal Conditioners<br />
A<br />
B<br />
C<br />
D<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
FEATURED PRODUCTS<br />
1/4 DIN Size Compact Paperless Recorder<br />
71VR1<br />
96-mm square panel size<br />
3.5-inch TFT color LCD display<br />
Max. 8-point each of analog and discrete inputs are stored, displayed and alerted.<br />
Max. 8-point discrete outputs can be assigned for alarm trips.<br />
Direct field inputs at the built-in terminals and optional remote inputs via Modbus RTU<br />
Data can be transferred to PC via the front IR port.<br />
IP 65 front panel<br />
Cost effective<br />
Flexible I/O configuration with Modbus extension<br />
Do x 2<br />
Di x 2<br />
Modbus RS-485<br />
Direct analog inputs<br />
Remote I/O<br />
Additional I/O<br />
9/16 DIN Size Paperless Recorder<br />
73VR Series<br />
144-mm square panel size<br />
5.5-inch TFT color LCD display<br />
Real time monitor at the host PC via Ethernet<br />
Touch panel operation<br />
Fully scalable system from 2 to 128 points<br />
IP 65 front panel<br />
Remote I/O Acquisition<br />
73VR1100<br />
• Wire saving remote input using<br />
the R3, R7 and other Modbus I/O<br />
modules<br />
• Max. 128 points<br />
Direct Universal Input<br />
73VR2100<br />
• Direct universal input from 2 to<br />
12 points<br />
• 100 msec. high speed data<br />
sampling up to 6 points<br />
Selectable Built-in I/O Modules<br />
73VR3100<br />
• Flexible input by selection of the R3<br />
input modules built into the rear slots<br />
• Remote control and display by PLC<br />
• Max. 64 points<br />
Remote I/O<br />
Direct Universal Input<br />
Built-in I/O Module<br />
M-019<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Electric Actuators with 1/1000 Resolution<br />
FEATURED PRODUCTS M 020<br />
Push<br />
Electrically modulated valve operation with 1/1000 resolution<br />
Brushless DC stepping motor assures long-life operation<br />
Programmable opening/closing speed for selected models<br />
DeviceNet and CC-Link models allow multiple valves and dampers connected in series to be<br />
remotely controlled and monitored.<br />
Pull<br />
Rotate<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
i<br />
J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Application: Cross-direction Profile Control<br />
Dilution water<br />
Image provided by Kobayashi Engineering Works, Ltd.<br />
Mini-Top<br />
Headbox<br />
The headbox provides<br />
a uniform and fully<br />
developed pulp.<br />
Pulp<br />
Distribution pipes<br />
The central attenuator produces an even CD basis weight profile<br />
and distributes diluted pulp to the headbox.<br />
Rotary and Linear Actuators for Valve and Machinery Control<br />
CSP<br />
MSP4 MSP5 MSP6<br />
PSN1<br />
PSN3<br />
Linear<br />
motion<br />
type<br />
Network Network Network<br />
150N 300N 700N 1200N<br />
2500N<br />
3000N<br />
5000N<br />
12000N<br />
Thrust<br />
Rotary<br />
motion<br />
type<br />
5N·m 10N·m 16N·m 33N·m 40N·m 100N·m<br />
200N·m<br />
Torque<br />
MRP4 MRP5 MRP6<br />
Network Network Network<br />
NEW NEW NEW<br />
MRM PRP-0 PRP-1<br />
ISP ’12 Specifications are subject to change without notice.<br />
M-020
M<br />
Signal Conditioners<br />
021 FEATURED PRODUCTS<br />
A<br />
B Surge Protectors Designed for Each Specific Device to be Protected<br />
C<br />
D M-Rester Series<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
E<br />
F<br />
G<br />
H<br />
i<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
J<br />
Series-connected multi-stage SPD<br />
Each model identified for specific sensors and devices: Easy to choose a right solution<br />
MDP Series<br />
MD7 Series<br />
MD6 Series<br />
✔ 4 to 20 mA, pulse train signal<br />
✔ Thermocouple<br />
✔ RTD<br />
✔ Potentiometer<br />
✔ Strain gauge / load cell<br />
✔ Pulse pickup<br />
✔ RS-485 / RS-422<br />
✔ Ethernet, DeviceNet, PROFIBUS, LONWORKS<br />
✔ DC / AC power supply<br />
✔ Life monitor function<br />
MDCAT<br />
PoE / 1000BASE-T Ethernet Use<br />
PoE (Power-over-Ethernet) compatible<br />
1000BASE-T / 100BASE-TX / 10BASE-T<br />
Ideal to protect network devices powered<br />
from Ethernet such as webcams<br />
DIN rail mounting and grounding available<br />
Parallel-Connected One-Port SPD for Power Supply<br />
MAKF: One-port SPD<br />
MAT2: Three-phase power line use<br />
Connected in parallel between the power and<br />
ground lines regardless of load current<br />
MDR2<br />
8-point Pulse Signal Use<br />
Protection for semiconductor switches<br />
of discrete signals<br />
PNP or NPN connection<br />
Applicable to multi (non-isolated)<br />
analog signals<br />
LED monitor indicating degradation of<br />
voltage limiter<br />
MAKF<br />
MAT2<br />
M-021<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Signal Conditioners<br />
Converting a field signal suitable<br />
for processing after conditioning<br />
✔ Signal Conversion<br />
✔ Signal Boosting (increases load drive capability)<br />
✔ Signal Isolation (stops ground loops)<br />
Available with wide combination of process signal I/O, power input and<br />
mounting configuration.<br />
Additionally, M-<strong>System</strong> offers the broadest line of signal splitters available.<br />
ISP ’12<br />
001
A<br />
002 Signal Conditioners Product Selection Guide<br />
Signal Conditioners Product Selection Guide<br />
A<br />
003<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Compact Plug-in<br />
Mini-M Series<br />
Compact Plug-in Signal Splitters<br />
Mini-MW Series<br />
Ultra-Slim<br />
M6 Series<br />
Low Profile<br />
M5-UNIT Series<br />
Low Profile Signal Splitters<br />
W5-UNIT Series<br />
Thin Profile<br />
M3-UNIT Series<br />
Thin Profile<br />
M3S-UNIT Series<br />
Hybrid IC Isolation Amplifiers<br />
20 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
P.008 P.106 P.138 P.184 P.202 P.214 P.234 P.246<br />
Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access<br />
Connection M3 screw terminal M3 screw terminal<br />
Tension-clamp, M3 screw terminal<br />
Euro terminal<br />
M3.5 screw terminal<br />
Input: M3.5 screw terminal<br />
Output & power: M3 screw terminal<br />
Removable terminal block<br />
Removable terminal block<br />
Isolation Three ways Four ways Three / four ways Three ways Four ways Three ways Three / Four ways<br />
Dielectric Strength 2000V AC 2000V AC 2000V AC<br />
Range Selectability<br />
Specified when ordering or<br />
PC / One-Step Cal programming<br />
Specified when ordering or<br />
PC programming<br />
Specified when ordering or<br />
PC programming<br />
DC powered: 2000V AC<br />
AC powered: 1500V AC<br />
Specified when ordering<br />
2000V AC<br />
Specified when ordering or<br />
DIP switch programming<br />
DC powered: 2000V AC<br />
AC powered: 1500V AC<br />
PC / One-Step Cal programming<br />
2000V AC<br />
Specified when ordering or<br />
PC programming<br />
Dual Output – Yes Selected models – Yes – Selected models<br />
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC (universal)<br />
Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F)<br />
Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail<br />
M6D/S: W5.9 × H94 × D102 mm<br />
Dimensions<br />
W23 [29.5] × H76 × D124 mm W29.5 × H89 × D124 mm<br />
(0.23” × 3.70” × 4.02”)<br />
W25 × H97 × D41 mm W45 × H97 × D41 mm W18 × H106 × D110.5 mm W12 × H106 × D110.5 mm<br />
(0.91” [1.16”] × 2.99” × 4.88”) (1.16” × 3.51” × 4.88”) M6N: W7.5 × H102 × D102 mm<br />
(0.98” × 3.82” × 1.61”) (1.77” × 3.82” × 1.61”) (0.71” × 4.17” × 4.35”) (0.47” × 4.17” × 4.35”)<br />
(0.30” × 4.02” × 4.02”)<br />
Standards & Approvals<br />
CE / UL / C-UL for selected models /<br />
RoHS for selected models<br />
CE / UL / C-UL for selected models /<br />
RoHS for selected models<br />
CE / UL / C-UL for selected models / RoHS CE for selected models / RoHS CE for selected models / RoHS<br />
CE / UL / C-UL for selected models /<br />
RoHS for selected models<br />
CE / RoHS for selected models<br />
◆ 2-Port Isolation<br />
❚ Input Isolation<br />
20VF-1<br />
20VS2-1<br />
20VS2-3<br />
20VS4-384<br />
20VS5-150<br />
20VS5-200<br />
20VS5-500<br />
❚ Output Isolation<br />
20VF-2<br />
20VS2-2<br />
20VS2-4<br />
20VS5-140<br />
20VS5-170<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Signal Conditioners<br />
Rack-mounted<br />
Mini-M Series Mini-MW Series M6 Series M5-UNIT W5-UNIT M3-UNIT M3S-UNIT<br />
Input Loop Powered Isolator M2SN – M6xSN M5SN – – –<br />
Universal Input M2XU, M2XUM – M6xXU – – M3LU2, M3LU –<br />
DC Input<br />
M2XV2, M2LV, M2VS, M2FV<br />
M2VF, M2VF2, M2VF3, M2VV<br />
W2VS, W2VF<br />
M6xYV, M6xXV, M6xVS,<br />
M6xVF, M6xWVS<br />
M5VS, M5MV,<br />
M5VF, W5VSH<br />
W5VS, W5FV<br />
M3LV<br />
M3SYV, M3SXV, M3SVS,<br />
M3SWVS<br />
High Current Output – – – – – – –<br />
Thermocouple Input M2XT2, M2TS W2XT, W2TS M6xXT M5TS W5TS M3LT M3SXT<br />
RTD Input M2XR2, M2LR, M2RS, M2RR W2XR, W2RS M6xXR M5RS W5RS M3LR M3SXR, M3SRS<br />
Potentiometer Input M2XM2, M2LPM, M2MS W2XM, W2MS M6xXM M5MS W5MS M3LM M3SXM, M3SMS<br />
Current Loop Supply<br />
M2D, M2D2, M2DYS, M2DY,<br />
M2DL, M2DNY, M2DYH2,<br />
M2DYH, M2DYHR, M2DU<br />
W2DYS, W2DY,<br />
W2DNY, W2DYH<br />
M6xDY M5DY W5DY M3LDY, M3DY M3SDY<br />
Self-Synch Input – – – – – – –<br />
Strain Gauge Input M2LCS – – – W5LCS M3LLC –<br />
AC Input M2TG, M2AC W2TG, W2AC – – – – –<br />
PT Input M2PA, M2PE W2PA, W2PE – M5PT – – –<br />
CT Input M2CA, M2CE, M2CEC W2CA, W2CE M6xCTC M5CT, M5CTC – – –<br />
Power Transducer – – – – – – –<br />
Frequency Input M2XPA3, M2SP W2SP M6xPA M5PA W5PA M3LPA2 –<br />
Encoder Input M2XRP2 – – – – – –<br />
Frequency Output M2AP W2AP M6xAP – – – –<br />
Pulse Isolator M2PP W2PP M6xPP – – – –<br />
Pulse Scaler M2PRU – – – – – –<br />
P/I Transducer M2PV W2PV – – – – –<br />
I/P Transducer – – – – – – –<br />
Limit Alarm M2AVS, M2SED, M2AS, M2AS1 – M6xXAS, M6xXAT, M6xXAR – – – –<br />
BCD Transducer – – – – – – –<br />
Math Function M2ADS, M2SBS, M2MLS, M2DIS W2VABS M6xXF2 – – – –<br />
Ratio/Bias M2REB, M2RTS – – – – – –<br />
Process Function<br />
M2XF2, M2FL, M2FLS,<br />
M2LMS, M2UDS2, M2UDS<br />
W2XF M6xXF1 – – – –<br />
Filter/Lag M2CDS, M2CRS – M6xXF1 – – – –<br />
Hold<br />
M2AMS2, M2AMS,<br />
M2PHS2, M2PHS<br />
– M6xXF3 – – – –<br />
Signal Selector M2SES2, M2SES, M2MNV – M6xXF2 – – – –<br />
Signal Generator M2MST – – – – – –<br />
Valve Positioner – – – – – – –<br />
Control Backup – – – – – – –<br />
Others – – – – – – –<br />
❚ Bidirectional Isolation<br />
20VS5-100<br />
◆ 3-Port Isolation<br />
20VS1A<br />
20VS2-01<br />
20VS2-02<br />
20VS3<br />
20VS8-210<br />
Signal Conditioners<br />
Product Selection Guide<br />
Signal Conditioners<br />
Rack-mounted<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
002<br />
Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
003
A<br />
004 Signal Conditioners Product Selection Guide<br />
Signal Conditioners Product Selection Guide<br />
A<br />
005<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Dual Output Super-mini<br />
Signal Conditioners<br />
Pico-M Series<br />
Plug-in Front Configurable<br />
MX-UNIT Series<br />
Plug-in<br />
M-UNIT Series<br />
Plug-in Signal Splitters<br />
W-UNIT Series<br />
Plug-in<br />
K-UNIT Series<br />
Space-saving Plug-in<br />
F-UNIT Series<br />
Space-saving Plug-in<br />
H-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Power Transducers<br />
Indicators<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Construction Connector on the base Plug-in Plug-in Plug-in Plug-in Plug-in Plug-in<br />
Connection M3.5 screw terminal, DCS M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal<br />
Isolation Four ways Three ways Three ways Four ways Three / four ways Three ways Three ways<br />
Dielectric Strength 1500V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC 500V AC<br />
Range Selectability<br />
Specified when ordering or<br />
PC programming<br />
Front key programming<br />
Specified when ordering or<br />
PC / Programming unit programming<br />
Specified when ordering or<br />
PC / Programming unit programming<br />
Specified when ordering<br />
Specified when ordering or<br />
PC / Programming unit programming<br />
Specified when ordering or<br />
PC / Programming unit programming<br />
Dual Output Yes – – Yes Selected models – –<br />
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC DC<br />
Operating Temperature 0 to 55°C (32 to 131°F) -5 to +55°C (23 to 131°F) -5 to +60°C (23 to 140°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)<br />
Mounting Installation Base (Surface) Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail<br />
Dimensions<br />
Standards & Approvals<br />
W17.5 × H48 × D75 mm<br />
(0.69” × 1.89” × 2.95”)<br />
CE for selected models /<br />
RoHS for selected models<br />
W50 × H80 × D123 [132] mm<br />
(1.97” × 3.15” × 4.84” [5.20”] )<br />
CE for selected models /<br />
RoHS for selected models<br />
W50 × H80 × D127 [136] mm<br />
(1.97” × 3.15” × 5” [5.35”] )<br />
CE / UL / C-UL for selected models /<br />
RoHS for selected models<br />
W50 × H80 × D136 mm<br />
(1.97” × 3.15” × 5.35”)<br />
CE for selected models /<br />
RoHS for selected models<br />
W50 × H80 × D123 [132] mm<br />
(1.97” × 3.15” × 4.84” [5.20”] )<br />
CE for selected models /<br />
RoHS for selected models<br />
W26 × H100 × D137 mm<br />
(1.02” × 3.94” × 5.39”)<br />
RoHS for selected models<br />
W26 × H93 × D137 mm<br />
(1.02” × 3.66” × 5.39”)<br />
RoHS for selected models<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
004<br />
Signal Conditioners<br />
Rack-mounted<br />
Pico-M Series MX-UNIT M-UNIT W-UNIT K-UNIT F-UNIT H-UNIT<br />
Input Loop Powered Isolator – – SN – KSN FSN HSN<br />
Universal Input – – JUA – – – –<br />
DC Input<br />
M8YV1, M8XV3, M8VS1,<br />
M8YS1, M8YC1<br />
MXV, MXF JV, SV, SVF, CV, OT2, OR2, SVB WJV, WVS, WVS2, WVF<br />
KYV, KVS, KWVS,<br />
KWVS2, KSF, KV<br />
FJV, FVS, FVF, FV<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
HJV, HVS, HVF, HV<br />
High Current Output – – VA, SVA, 99SVA – – – –<br />
Thermocouple Input M8XT3, M8TS1 MXT JT, TCS, OTT2, OTR2 WJT, WTS KTS, KWTS FJT, FTS HJT, HTS<br />
RTD Input M8XR3, M8RS1 MXR JR, RB, RBS, DR, DRS, CVRTD WJR, WRS, WRS2 KR, KRS, KWRS, KWRS2 FJR, FR, FRS HJR, HR, HRS<br />
Potentiometer Input M8XM3, M8MS1 – JM, PM, PMS, CVR1, PM2W WJM, WMS, WMS2 KM, KMS, KWMS, KWMS2 FJM, FM, FMS HJM, HM, HMS<br />
Current Loop Supply M8DY1 –<br />
DS, DS-48, DS-824, JDL,<br />
YVD, YVDU, FND, FNDS<br />
WDY, WDNY<br />
KD, KDY, KWDY, KWDNY,<br />
KWLD<br />
FD, FJDL, FDY2, FDL, FDU<br />
HD, HJDL, HDY2, HDL, HDU<br />
Self-Synch Input – MXS JS WJS – – –<br />
Strain Gauge Input M8LCS MXLC, MXLCF LC, LCS, LC2, LCS2, LCF, MLV – KG, KGS FLC, FLCS –<br />
AC Input – – TG, AC WTG, WAC KTG, KAC FTG, FAC –<br />
PT Input M8PT – PT, PTPH, PTAF WPT KP, KPE, KPNA, KPNE FPA, FPE HPA, HPE<br />
CT Input M8CT1, M8CTC –<br />
Power Transducer – –<br />
CTH, CTC, CTCS, CTS,<br />
CT, CTPH,CTAF<br />
MUWT, MEWT, MEWTF, MERP,<br />
MEPF, MEPA, HZ<br />
WCT<br />
WEWT, WERP, WEPF, WEPA,<br />
WHZ<br />
KCEC, KC, KCE,<br />
KCNA, KCNE, KCEZ<br />
FCA, FCE<br />
HC, HCE<br />
– – –<br />
Frequency Input M8PA1 MXPA JPA, JPA2, MPAU, JPQ2, EP, SP, JTY2 WJPA, WSP KEP, KSP, KPAU FJPA, FSP HJPA, HSP<br />
Encoder Input – – JRP2, JRQ2, RPPD – – – –<br />
Frequency Output M8AP1 MXAP AP, APU, JARP, MTD – KAP, KAPU FAP HAP, HAPU<br />
Pulse Isolator M8PP1 – PP, PPD, YPD, RPPD, MNS WYPD KMT, KYPD, KWYPD FPP HPP<br />
Pulse Scaler – – JPR2, PRU, JFR2, PDU, JPS3 – KPRU – HPR<br />
P/I Transducer – – PV – – – HPV<br />
I/P Transducer – – VP – – – HVP, HVPN<br />
Limit Alarm M8SED1 –<br />
AS4V, AS4T, AS4R, AS4M, AS4CT,<br />
AS4LC, MSEF, AS, ASW, ASW2, ASL,<br />
ASWL, ASWL2, AYAV, AYDV, ASD1, ASD<br />
–<br />
KS2V, KS2TR, KSED, KSE, KS,<br />
KS2, KSL, KSL2<br />
BCD Transducer – – AD3V, AD2LC, DA3 – – – –<br />
Math Function – – JF, JFK, ADS, SBS, MLS, DIS WJF, WJFK, WADS KADS, KSBS, KMLS, KDIS FJF HJF<br />
Ratio/Bias – – REB, REBS, RT, RTS – KB, KBS FRT, FRTS, FRTD –<br />
Process Function – MXF<br />
JFX, JFX1, FN, FNS, LM, LMS, UD,<br />
UDS, MLG<br />
WJFX KX, KN, KNS, KL, KLS, KU, KUS<br />
FAS, FASD<br />
FJFX, FFL, FLM, FLMS, FUD,<br />
FUDS<br />
Filter/Lag M8CD1 – JFT, JFTS, CD, CDS, CR, CRS WJFT KF, KFS FJFT, FCR, FCRS HJFT<br />
Hold – – AM, AMS, PH, PHS – KA, KAS, KH, KHS – –<br />
Signal Selector – – SE, SES, JFKM, MNV – – FSE, FSES –<br />
Signal Generator – MXMS MS, MFS, MFS2 – – – –<br />
Valve Positioner – –<br />
ABM, MP, MEX-B, MEX-C, MEX-D,<br />
MEX-E, MEX-F, MEX-M1<br />
– – – –<br />
Control Backup – MXAB, MXCB JB2, AB2, ABF3, CB2 – – – –<br />
Others – – MDC (Excitation Supply), ABS2 – – – –<br />
Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.<br />
HAS<br />
HJFX, HN<br />
Signal Conditioners<br />
Product Selection Guide<br />
Signal Conditioners<br />
Rack-mounted<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
005
A<br />
006 Signal Conditioners Product Selection Guide Signal Conditioners Product Selection Guide<br />
A<br />
007<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Dual Output<br />
10-RACK Series<br />
DCS Front End<br />
18-RACK Series<br />
Interposing Relays<br />
38-RACK Series<br />
Configurable Signal Conditioners — Choose your way of configuration.<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Signal Conditioners<br />
Rack-mounted<br />
Construction Rack-mounted Rack-mounted Rack-mounted<br />
Connection M3.5 screw terminal, DCS M3.5 screw terminal, DCS M3.5 screw terminal<br />
Isolation Four ways Four ways –<br />
Dielectric Strength 500V AC 1500V AC –<br />
Range Selectability<br />
Specified when ordering or<br />
PC / Programming unit programming<br />
Specified when ordering or<br />
PC / Programming unit programming<br />
Dual Output Yes Yes –<br />
Power Input AC / DC AC / DC DC<br />
Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)<br />
Mounting Standard rack Standard rack Standard rack<br />
Dimensions<br />
W25 × H99 × D180 mm<br />
(0.98” × 3.90” × 7.09”)<br />
W24 × H110 × D110 mm<br />
(0.94” × 4.33” × 4.33”)<br />
–<br />
W24 × H110 × D110 mm<br />
(0.94” × 4.33” × 4.33”)<br />
Standards & Approvals – – –<br />
10-RACK 18-RACK 38-RACK<br />
Input Loop Powered Isolator 10SN 18SN<br />
Universal Input – –<br />
DC Input<br />
10VS4, 10YS, 10YK, 10JV,<br />
10VS, 10VK, 10VF<br />
18YS, 18YK, 18YC, 18JV, 18VS,<br />
18VK<br />
High Current Output – –<br />
Thermocouple Input 10JT, 10TS, 10TK 18JT, 18TS, 18TK<br />
RTD Input 10JR, 10JRE, 10RS, 10RK 18JR, 18RS, 18RK<br />
Potentiometer Input 10JM, 10MS, 10MK 18JM, 18MS, 18MK<br />
Current Loop Supply 10D, 10JDL, 10DY, 10DNY, 10DU 18JDL, 18DY, 18JDN, 18DU<br />
Self-Synch Input – –<br />
Strain Gauge Input 10LCS, 10LCK –<br />
AC Input 10TG, 10AC 18TG, 18AC<br />
Visit M-<strong>System</strong><br />
PT Input 10PA, 10PE 18PE<br />
Web Site.<br />
CT Input 10CA, 10CE 18CE<br />
Power Transducer 10EWT, 10ERP, 10EPF, 10EPA, 10EHZ 18WT, 18RP, 18PF, 18PA, 18HZ<br />
Frequency Input 10JPA, 10SP 18JPA<br />
Encoder Input – –<br />
Frequency Output 10AP –<br />
Pulse Isolator 10PP 18PP<br />
Pulse Scaler 10PR 18PR<br />
P/I Transducer 10PV 18PV<br />
I/P Transducer 10VP, 10VPN 18VP<br />
Limit Alarm 10AS 18AS2, 18AT, 18AR<br />
BCD Transducer – –<br />
Math Function 10JF 18JF<br />
Ratio/Bias – –<br />
Process Function 10JFX, 10FNS 18JFX, 18JN<br />
Filter/Lag 10JFT –<br />
Hold – –<br />
Signal Selector – –<br />
Signal Generator – –<br />
Valve Positioner – –<br />
Control Backup 10ABS –<br />
Others 10BOS 18DI, 18DO, 18APT, 18YVT<br />
Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.<br />
n PC Configurator Software<br />
M-<strong>System</strong>’s PC Configurator programs are packed with advanced features. Not only the I/O ranging, but also linearization, fine<br />
calibration, filters, diagnostics are available depending on the signal conditioner’s function. In addition, many configurators are<br />
provided with monitoring and simulating functions to help you confirm the module’s proper operation, calibrate it at the field site<br />
and commissioning the receiving instrument at the same time.<br />
This type of programming is especially convenient when an identical configuration setting is required for<br />
multiple modules. It saves you<br />
a considerable time by simply<br />
calling a pre-defined setting<br />
and downloading it from the PC<br />
software.<br />
Basic Setting View<br />
Trend Graph View<br />
The PC configuration is available<br />
with various signal conditioner<br />
series including M2X, W2X, M3L,<br />
M3SX and M6X Series.<br />
n “One-Step Cal” Configuration<br />
Even when you do not have a PC at your disposal, a simulator and a multimeter can help you program I/O ranges.<br />
The internal DIP switches are used to configure input and output type.<br />
Once the module is configured, precise ranges can be set with the front<br />
control buttons using a simulator connected to the input terminals and a<br />
multimeter connected to the output terminals as a reference.<br />
For example, suppose that the DIP switches are configured for the J type<br />
thermocouple. Turn the power supply to the transmitter on and press<br />
MODE button to enter to the Input Calibration Mode. Apply the desired<br />
minimum (e.g. 0°C) and maximum (e.g. 400°C) input levels and push the<br />
DOWN (zero) and UP (span) respectively to set the input range to 0 to 400°C.<br />
Then the output range can be calibrated in a similar manner after moving to<br />
the Output Calibration Mode.<br />
The front LED’s colors and flashing patterns help you easily identify the<br />
transmitter’s status and confirm the setup actions in each step of Calibration<br />
Modes.<br />
“One-Step Cal” configuration is available with the M3L and M2L Series signal<br />
conditioners.<br />
n Front Control Buttons with Local Display<br />
MODE Button<br />
UP Button<br />
DOWN Button<br />
Simulator<br />
Connect the M3LU to a simulator and<br />
a multimeter and to a power source.<br />
The MX Series signal conditioners and the AS4 Series limit alarms are provided with two displays on the front face: 4-digit DATA<br />
display and 2-digit ITEM display. Using Up/Down buttons, configuration is simple by calling parameters’ ID numbers (ITEM) and<br />
choosing values (DATA).<br />
The M7E Series limit alarms are provided with a multi-line LCD display, which shows the parameters and selections in text to guide<br />
you through the programming procedure:<br />
LCD Display<br />
intuitive, easy programming just like operating<br />
your mobile phone. You won’t need to consult<br />
DATA Display<br />
the instruction manual.<br />
Up Button<br />
Mode Button<br />
Polarity LED<br />
ITEM No. Display<br />
Down Button<br />
Set Button<br />
These displays indicate process values once Programming<br />
DATA<br />
commissioned at the field site, and the software’s<br />
Error LED<br />
PC Configurator<br />
UP-DOWN Keys<br />
Jack<br />
“programmable” mode can be locked<br />
out in order to prevent unwanted changes in<br />
the setting.<br />
ITEM No.<br />
UP-DOWN Keys<br />
MX Series Front Panel<br />
M7E Series Front Panel<br />
Input<br />
M3L Series Front Panel<br />
Power Source<br />
M3SX Series<br />
Output<br />
Multimeter<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Signal Conditioners<br />
Product Selection Guide<br />
Signal Conditioners<br />
Rack-mounted<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
006<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
007
A<br />
008<br />
Compact Plug-in<br />
Mini-M Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
M2 Series Signal Conditioners are designed to accept a largest range of process signal<br />
inputs and provide a standard and non-standard DC output.<br />
◆◆<br />
M2 use a compact-size, plug-in socket base for<br />
quick installation or replacement of modules without<br />
disturbing wiring.<br />
◆◆<br />
2000V AC isolation<br />
◆◆<br />
Standard DIN rail or surface mounting<br />
◆◆<br />
Base socket included with modules<br />
◆◆<br />
Selectable 100–240V AC/24V DC power input<br />
◆◆<br />
Fixed range or PC programmable models<br />
selectable<br />
◆◆<br />
CE marking and UL/C-UL Class 1 Div 2 approval<br />
(selected models)<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
Construction<br />
Connection<br />
Housing material<br />
Isolation<br />
Operating temperature<br />
Mounting<br />
Dielectric strength<br />
AC power input<br />
DC power input<br />
Plug-in<br />
M3 screw terminals (torque 0.8 N·m)<br />
Flame-resistant resin (black)<br />
Input to output to power<br />
-5 to +55°C (23 to 131°F)<br />
Surface or DIN rail<br />
2000V AC @1 minute<br />
(input to output to power to ground)<br />
Operational voltage range 85 – 264V<br />
(90 – 264V for UL)<br />
Operational voltage range for 24V ±10%,<br />
11 – 27V, or 85 – 150V (110V ±10% for UL)<br />
8-pin Mounted Modules<br />
70.5 (2.78)<br />
21.5 (.85)<br />
DIN RAIL<br />
35mm wide<br />
2–4.2x5<br />
(.17x.20)<br />
MTG HOLE<br />
6 (.24) deep<br />
8–M3<br />
SCREW<br />
10 (.39) 84 (3.31)<br />
15 (.59)<br />
114 (4.49)<br />
[4 (.16)]<br />
23 (.91)<br />
1<br />
5<br />
9<br />
6 (.23)<br />
59 (2.32)<br />
72 (2.83)<br />
• When mounting, no extra space is needed between units.<br />
8<br />
4<br />
12<br />
14 13<br />
4 (.16)<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
Signal Conditioners<br />
n DC Inputs, Isolators<br />
Model Function Page<br />
M2SN Input Loop Powered Isolator P.010<br />
n Temperature & Sensor Inputs<br />
Model Function Page<br />
M2XT2 Thermocouple Transmitter (PC programmable) P.026<br />
MX-UNIT Series<br />
M2XU Universal Transmitter (PC programmable) P.012<br />
M2TS Thermocouple Transmitter P.028<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
M2XUM<br />
Universal Transmitter<br />
(PC programmable; Modbus-RTU communication)<br />
P.014<br />
M2XV2 Signal Transmitter (PC programmable) P.016<br />
M2LV Signal Transmitter (field- and PC-configurable) P.018<br />
M2VS Signal Transmitter P.019<br />
M2FV Signal Transmitter (field-configurable) P.020<br />
M2VF Signal Transmitter (high speed response) P.021<br />
M2XR2 RTD Transmitter (PC programmable) P.030<br />
M2LR RTD Transmitter (field- and PC-configurable) P.032<br />
M2RS RTD Transmitter P.033<br />
M2RR Resistance/Resistance Converter P.034<br />
M2XM2 Potentiometer Transmitter (PC programmable) P.035<br />
M2LPM<br />
Potentiometer Transmitter<br />
(field- and PC-configurable)<br />
P.036<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Rack-mounted<br />
M2VF2<br />
M2VF3<br />
Signal Transmitter<br />
(ultra-high speed response 30μsec.)<br />
Signal Transmitter<br />
(high-accuracy, ultra-high speed response 30 μsec.)<br />
P.022<br />
P.023<br />
M2VV Voltage Divider P.024<br />
M2MS Potentiometer Transmitter P.037<br />
M2LCS Strain Gauge Transmitter P.038<br />
M2TG Tachogenerator Transmitter P.039<br />
M2AC AC Transmitter P.040<br />
M2PA PT Transmitter (average sensing, RMS calibrated) P.041<br />
008<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Compact Plug-in Mini-M Series<br />
A<br />
009<br />
Signal Conditioners<br />
Model Function Page<br />
M2PE PT Transmitter (RMS sensing) P.042<br />
M2CA CT Transmitter (average sensing, RMS calibrated) P.043<br />
M2CE CT Transmitter (RMS sensing) P.044<br />
M2CEC AC Current Transmitter (clamp-on current sensor) P.046<br />
n DC Supplies<br />
Model Function Page<br />
M2D Current Loop Supply (non-isolated) P.048<br />
M2D2 Current Loop Supply (non-isolated) P.049<br />
M2DYS Current Loop Supply P.050<br />
M2DY Current Loop Supply P.051<br />
M2DL<br />
Current Loop Supply<br />
(with square root extractor; non-isolated)<br />
P.052<br />
M2DNY Current Loop Supply (with square root extractor) P.053<br />
M2DYH2 Current Loop Supply (applicable to HART signal) P.054<br />
M2DYH Current Loop Supply (applicable to HART signal) P.055<br />
M2DYHR Current Repeater (applicable to HART signal) P.056<br />
M2DU Current Loop Supply (10-50mA loop) P.057<br />
n Pneumatic Transducers<br />
Model Function Page<br />
M2PV P/I Transducer P.058<br />
n Limit Alarms<br />
Model Function Page<br />
M2AVS DC Alarm P.060<br />
M2SED DC Alarm (thumbwheel switch adjustments) P.062<br />
M2AS<br />
DC Alarm<br />
(thumbwheel switch adjustments; DPDT output)<br />
P.063<br />
M2AS1<br />
DC Alarm<br />
(thumbwheel switch adjustments; single SPDT output)<br />
P.064<br />
n Frequency I/O<br />
Model Function Page<br />
M2XPA3 Frequency Transmitter (PC programmable) P.066<br />
M2SP Low Frequency Transmitter (50 Hz minimum) P.068<br />
M2XRP2<br />
Encoder Speed Transmitter<br />
(PC programmable; built-in excitation)<br />
P.070<br />
M2AP DC/Frequency Converter P.072<br />
M2PP Pulse Isolator P.074<br />
M2PRU Pulse Scaler (field-configurable) P.076<br />
n Function Modules<br />
Model Function Page<br />
M2ADS Adder P.078<br />
M2SBS Subtractor P.079<br />
M2MLS Multiplier P.080<br />
M2DIS Divider P.081<br />
M2REB Ratio/Bias Transmitter (output bias) P.082<br />
M2RTS Ratio/Bias Transmitter (input bias) P.084<br />
M2XF2 Linearizer (PC programmable) P.086<br />
M2FL Square Root Extractor (non-isolated) P.088<br />
M2FLS Square Root Extractor (3-port isolation) P.089<br />
M2LMS Limiter P.090<br />
M2UDS2<br />
Inverted Output Transmitter<br />
(with simple loop test output)<br />
P.091<br />
M2UDS Inverted Output Transmitter P.092<br />
M2CDS Delay Buffer P.093<br />
M2CRS Ramp Buffer P.094<br />
M2AMS2 Track/Hold (with simple loop test output) P.095<br />
M2AMS Track/Hold P.096<br />
M2PHS2 Peak Hold (with simple loop test output) P.097<br />
M2PHS Peak Hold P.098<br />
M2SES2 High/Low Selector (with simple loop test output) P.100<br />
M2SES High/Low Selector P.101<br />
M2MNV Analog Switching Module P.102<br />
M2MST Parameter Generator P.104<br />
n Installation Base<br />
Model Function Page<br />
M2BS-16 Installation Base (16 positions) ***<br />
M2BS-8 Installation Base (8 positions) ***<br />
M2BS2 Installation Base ***<br />
M2BC<br />
Communication Controller<br />
(Mitsubishi Control & Communication Link use) ***<br />
M2BD Communication Controller (DeviceNet use) ***<br />
n Accessories<br />
Model Function Page<br />
P-M2 Socket Cover, M2BS use ***<br />
M2BW Extender Module ***<br />
M2DM Blank Filler Module ***<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Signal Conditioners<br />
Product Selection Guide<br />
Signal Conditioners<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
Rack-mounted<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
009
A<br />
Four-wire<br />
Signal Conditioners<br />
Signal Conditioners<br />
106<br />
Compact Plug-in Signal Splitters<br />
Two-wire<br />
Signal Conditioners<br />
Mini-MW Series<br />
The W2 Series Signal Splitters provide two isolated outputs of independent ranges.<br />
Power Transducers<br />
Indicators<br />
◆◆<br />
W2 use a compact-size, plug-in socket base for<br />
quick installation or replacement of modules without<br />
disturbing wiring.<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
◆◆<br />
2000V AC isolation<br />
◆◆<br />
Standard DIN rail or surface mounting<br />
◆◆<br />
Base socket included with modules<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
◆◆<br />
Selectable 100–240V AC/24V DC power input<br />
◆◆<br />
Fixed range or PC programmable models<br />
selectable<br />
Electric Actuators<br />
& Position Sensors<br />
◆◆<br />
CE marking and UL/C-UL Class 1 Div 2 approval<br />
(selected models)<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
Construction<br />
Connection<br />
Housing material<br />
Isolation<br />
Operating temperature<br />
Mounting<br />
Dielectric strength<br />
AC power input<br />
DC power input<br />
Plug-in<br />
M3 screw terminals (torque 0.8 N·m)<br />
Flame-resistant resin (black)<br />
Input to output 1 to output 2 to power<br />
-5 to +55°C (23 to 131°F)<br />
Surface or DIN rail<br />
2000V AC @1 minute<br />
(input to output 1 to output 2 to power to ground)<br />
Operational voltage range 85 – 264V<br />
(90 – 264V for UL)<br />
Operational voltage range for 24V ±10%,<br />
11 – 27V, or 85 – 150V (110V ±10% for UL)<br />
89 (3.50)<br />
53 (2.09)<br />
23 (.91)<br />
10 (.39)<br />
84 (3.31)<br />
114 (4.49)<br />
DIN RAIL<br />
35mm wide<br />
[4 (.16)]<br />
2–4.2x5<br />
(.17x.20)<br />
MTG HOLE<br />
6 (.24) deep<br />
11–M3<br />
SCREW<br />
6<br />
9<br />
3<br />
2<br />
5<br />
1<br />
4<br />
8 7<br />
11 10<br />
22 (.87)<br />
29.5 (1.16)<br />
6 (.23)<br />
59 (2.32)<br />
72 (2.83)<br />
• When mounting, no extra space is needed between units.<br />
M6 Series<br />
M5-UNIT Series<br />
n DC Inputs<br />
n DC Supplies<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Signal Conditioners<br />
Rack-mounted<br />
Model Function Page<br />
W2VS Signal Transmitter P.107<br />
W2VF Signal Transmitter (high speed response) P.108<br />
n Temperature & Sensor Inputs<br />
Model Function Page<br />
W2XT Thermocouple Transmitter (PC programmable) P.110<br />
W2TS Thermocouple Transmitter P.112<br />
W2XR RTD Transmitter (PC programmable) P.114<br />
W2RS RTD Transmitter P.116<br />
W2XM Potentiometer Transmitter (PC programmable) P.118<br />
W2MS Potentiometer Transmitter P.119<br />
W2TG Tachogenerator Transmitter P.120<br />
W2AC AC Transmitter P.121<br />
W2PA PT Transmitter (average sensing, RMS calibrated) P.122<br />
W2PE PT Transmitter (RMS sensing) P.123<br />
W2CA CT Transmitter (average sensing, RMS calibrated) P.124<br />
W2CE CT Transmitter (RMS sensing) P.125<br />
Model Function Page<br />
W2DYS Current Loop Supply P.126<br />
W2DY Current Loop Supply P.127<br />
W2DNY Current Loop Supply (with square root extractor) P.128<br />
W2DYH Current Loop Supply (applicable to HART signal) P.129<br />
n Pneumatic Transducers<br />
Model Function Page<br />
W2PV P/I Transducer P.130<br />
n Frequency I/O<br />
Model Function Page<br />
W2SP Low Frequency Transmitter (50 Hz minimum) P.131<br />
W2AP DC/Frequency Converter P.132<br />
W2PP Pulse Isolator P.134<br />
n Function Modules<br />
Model Function Page<br />
W2XF Linearizer (PC programmable) P.136<br />
W2VABS Absolute Value Output Transmitter P.137<br />
106<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
A<br />
138<br />
Ultra-Slim<br />
M6 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Ultra-slim, Space saving, Low power consumption.<br />
High performance transmitters with wide selection of input and output ranges.<br />
◆◆<br />
Selectable connection method – Tension-Clamp, Screw terminal or Euro terminal.<br />
◆◆<br />
Output load resistance 550Ω (at 4–20mA DC)<br />
◆◆<br />
Low power consumption<br />
◆◆<br />
Front power LED provided<br />
◆◆<br />
Fixed range or PC programmable models selectable. User-friendly versatile programming features provided.<br />
◆◆<br />
Status LED for PC programmable models.<br />
◆◆<br />
2000V AC isolation<br />
◆◆<br />
Optional fast response: Approx. 3.5 msec,<br />
voltage output (M6xYV)<br />
◆◆<br />
AC Power input available (M6xXU, M6xYV, M6xVS)<br />
SPECIFICATIONS<br />
Tension-Clamp<br />
(M6S Series)<br />
Screw Terminal<br />
(M6N Series)<br />
Euro Terminal<br />
(M6D Series)<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
Construction<br />
Ultra-slim<br />
M6S: Tension clamp<br />
Connection<br />
M6N: M3 screw terminal (torque 0.5 N·m)<br />
M6D: Euro terminal (torque 0.3 N·m)<br />
Housing material Flame-resistant resin (black)<br />
Isolation<br />
Input to output to power/<br />
Input to output 1 to output 2 to power<br />
Operating temperature -20 to +55°C (-4 to +131°F)<br />
Mounting<br />
DIN rail<br />
Dielectric strength<br />
2000V AC @1 minute<br />
(input to output to power to ground)<br />
AC Power input<br />
Operational voltage range 90 – 264V<br />
(M6xXU, M6xYV, M6xVS)<br />
DC Power input Operational voltage range 24V ±10%<br />
5.9mm<br />
(0.23”)<br />
7.5mm<br />
(0.30”)<br />
5.9mm<br />
(0.23”)<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
Signal Conditioners<br />
Model Function Page<br />
M6xSN Input Loop Powered Isolator P.141<br />
M6xYV Isolator P.142<br />
M6xXU Universal Transmitter (PC programmable) P.144<br />
M6xXV Signal Transmitter (PC programmable) P.146<br />
M6xVS Signal Transmitter P.148<br />
M6xVF<br />
Signal Transmitter<br />
(high-accuracy, ultra-high speed response 30 μsec.)<br />
P.149<br />
M6xWVS Signal Transmitter (two isolated outputs) P.150<br />
M6xXT Thermocouple Transmitter (PC programmable) P.152<br />
Model Function Page<br />
M6xPP Pulse Isolator P.162<br />
M6xXAS DC Alarm (PC programmable) P.164<br />
M6xXAT Thermocouple Alarm (PC programmable) P.166<br />
M6xXAR RTD Alarm (PC programmable) P.168<br />
M6xXF1 Function Module (PC programmable) P.170<br />
M6xXF2 2-input Math Function Module (PC programmable) P.174<br />
M6xXF3 Hold Function Module (PC programmable) P.176<br />
n Accessories<br />
x=S, N or D<br />
F-UNIT Series<br />
M6xXR RTD Transmitter (PC programmable) P.154<br />
Model Function Page<br />
H-UNIT Series<br />
M6xXM Potentiometer Transmitter (PC programmable) P.156<br />
M6xBS Installation Base P.178<br />
M6xDY Current Loop Supply P.157<br />
M6xPS1 Power Supply Module P.179<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Rack-mounted<br />
M6xCTC CT Transmitter (clamp-on current sensor) P.158<br />
M6xPA Frequency Transmitter P.159<br />
M6xXAP DC/Frequency Converter (PC programmable) P.160<br />
x=S, N or D<br />
M6xPS2 Power Supply Module (dual redundant) P.180<br />
M6-PSM Power Supply Module P.181<br />
M6xDM Blank Filler Module P.182<br />
x=S, N or D<br />
138<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Ultra-Slim M6 Series<br />
A<br />
139<br />
Signal Conditioners<br />
n Tension-Clamp Ultra-Slim Signal Conditioners M6S Series<br />
Two-wire<br />
Signal Conditioners<br />
◆◆<br />
5.9 mm (0.23”) wide ultra-slim design<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Power Transducers<br />
◆◆<br />
Spring terminal provides constant force, eliminating<br />
torque management, maintenance- free for retightening<br />
5 6 7 8<br />
DIN RAIL HOOK<br />
Indicators<br />
DIN RAIL<br />
35mm wide<br />
Limit Alarms<br />
94 (3.70)<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
5.9 (.23)<br />
1 2 3 4<br />
102 (4.02) [0.5 (.02)]<br />
• When mounting, no extra space is needed between units.<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
n Screw Terminal Ultra-Slim Signal Conditioners M6N Series<br />
◆◆<br />
7.5 mm (0.30”) wide ultra-slim design<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
◆◆<br />
Self-up screw style prevents falling off a terminal<br />
8–M3<br />
SCREW TERMINAL<br />
Signal Conditioners<br />
Product Selection Guide<br />
5 6 7 8<br />
DIN RAIL HOOK<br />
DIN RAIL<br />
35mm wide<br />
Mini-M Series<br />
102 (4.02)<br />
Mini-MW Series<br />
M6 Series<br />
n Euro Terminal Ultra-Slim Signal Conditioners M6D Series<br />
◆◆<br />
5.9 mm (0.23”) wide ultra-slim design<br />
◆◆<br />
Space saving euro type terminal<br />
7.5 (.30)<br />
EXTERNAL DIMENSIONS<br />
8–M3<br />
EURO TERMINAL<br />
1 2 3 4<br />
102 (4.02)<br />
[1 (.04)]<br />
• When mounting, no extra space is needed between units.<br />
5 6 7 8<br />
DIN RAIL HOOK<br />
DIN RAIL<br />
35mm wide<br />
mm (inch)<br />
Signal Conditioners<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
94 (3.70)<br />
1 2 3 4<br />
Rack-mounted<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
5.9 (.23)<br />
102 (4.02)<br />
[0.5 (.02)]<br />
• When mounting, no extra space is needed between units.<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
139
A<br />
Signal Conditioners<br />
140 Ultra-Slim M6 Series<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
n Installation Base model: M6xBS<br />
◆◆<br />
Power supplied to signal conditioners from the power supply module<br />
(via the installation base). Spring terminal provides constant force,<br />
eliminating torque management, maintenance- free for retightening<br />
◆◆<br />
High-density mounting: 16 units (M6D) in a space of 9.5 cm (3.75”)<br />
◆◆<br />
Holding up to 48 modules of M6 Series using 6 installation bases.<br />
Max.<br />
48 modules<br />
Installation Base<br />
(Model : M6xBS)<br />
Power supply module<br />
(Model : M6xPS1)<br />
or<br />
For redundant<br />
power supplies<br />
(Model : M6xPS2)<br />
9.5 cm<br />
(3.75”)<br />
Power supply through the backplane bus<br />
16 modules in a 9.5 cm- (3.75 in.-)<br />
wide space (M6S/M6D)<br />
Less than 30 cm (12 in.)<br />
with 48 modules (M6S/M6D)<br />
Signal Conditioners<br />
Product Selection Guide<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Mini-M Series<br />
n M6SBS<br />
n M6NBS<br />
n M6DBS<br />
1.5 (.45)<br />
14<br />
(.55)<br />
70 (2.76)<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M 49 (1.93) Series[3 (.12)]<br />
37 (1.46)<br />
MX-UNIT Series 3–4.5 (.18) dia.<br />
MTG HOLE<br />
M-UNIT Series 2 (.08) deep<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Signal Conditioners<br />
Rack-mounted<br />
11.5 (.45)<br />
99 (3.90)<br />
70 (2.76)<br />
5 (.20)<br />
5 (.20)<br />
14<br />
(.55)<br />
11.5 (.45)<br />
101 (3.98)<br />
72 (2.83)<br />
5 (.20)<br />
5 (.20)<br />
14<br />
(.55)<br />
116 (4.57)<br />
49 (1.93)<br />
37 (1.46)<br />
[3 (.12)]<br />
3–4.5 (.18) dia.<br />
MTG HOLE<br />
2 (.08) deep<br />
27 (1.06) [5 (.20)]<br />
61.6 (2.43) [3 (.12)]<br />
3–4.5 (.18) dia.<br />
MTG HOLE<br />
2 (.08) deep<br />
22.5<br />
49.8 (1.96)<br />
(.89)<br />
14<br />
(.55)<br />
49 (1.93)<br />
DIN RAIL<br />
35mm wide<br />
18 (.71)<br />
11.5 (.45)<br />
101 (3.98)<br />
72 (2.83)<br />
5 (.20)<br />
5 (.20)<br />
14<br />
(.55)<br />
116 (4.57)<br />
61.627 (2.43) (1.06) [5 (.20)] [3 (.12)]<br />
3–4.5 (.18) dia.<br />
MTG HOLE<br />
2 (.08) deep<br />
49.8 (1.96) 22.5<br />
(.89)<br />
11.5 (.45)<br />
99 (3.90)<br />
70 (2.76)<br />
5 (.20)<br />
5 (.20)<br />
14<br />
(.55)<br />
116 (4.57)<br />
14<br />
(.55)<br />
49 (1.93)<br />
DIN RAIL<br />
35mm wide<br />
18 (.71)<br />
2749 (1.06) (1.93) [5 (.20)] [3 (.12)]<br />
37 (1.46)<br />
3–4.5 (.18) dia.<br />
MTG HOLE<br />
2 (.08) deep<br />
22.5<br />
(.89)<br />
2 (.08)<br />
51 (2.01)<br />
DIN RAIL<br />
35mm wide<br />
11.5 (.45)<br />
99 (3.90)<br />
70 (2.76)<br />
5 (.20)<br />
5 (.20)<br />
14<br />
(.55)<br />
116 (4.57)<br />
116 (4.57)<br />
49 (1.93) 27 (1.06) [3 [5(.12)]<br />
(.20)]<br />
37 (1.46)<br />
3–4.5 (.18) dia.<br />
MTG HOLE<br />
2 (.08) deep<br />
22.5<br />
(.89)<br />
2 (.08)<br />
51 (2.01)<br />
DIN RAIL<br />
35mm wide<br />
27 (1.06) [5 (.20)]<br />
22.5<br />
(.89)<br />
14<br />
(.55)<br />
49 (1.93)<br />
DIN RAIL<br />
35mm wide<br />
116 (4.57)<br />
140<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
A<br />
184<br />
Low Profile<br />
M5-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
M-<strong>System</strong>'s M5 Series Transmitters are designed to accept a wide variety of process<br />
signal input and provide a standard and non-standard DC output.<br />
◆◆<br />
Only 41 mm (1.61 in") deep modules can be<br />
installed anywhere, even behind the panel cover<br />
◆◆<br />
The M5 Series features single channel four-wire<br />
models<br />
◆◆<br />
Standard DIN rail mounting<br />
◆◆<br />
2000V AC isolation (1500V AC for AC powered)<br />
◆◆<br />
Selectable power input 24V DC, 85–264V AC<br />
◆◆<br />
Power indicator LED<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
Construction<br />
Terminal block<br />
Connection<br />
M3.5 screw terminals<br />
(nickel-plated steel; torque 0.8 N·m)<br />
Housing material Flame-resistant resin (black)<br />
Isolation<br />
Input to output to power<br />
Operating temperature -5 to +55°C (23 to 131°F)<br />
Power LED<br />
Green light turns on when the power is supplied<br />
Mounting<br />
DIN rail<br />
Dielectric strength<br />
DC powered<br />
AC powered<br />
High dielectric strength<br />
Input to output to power to ground<br />
2000V AC @1 minute<br />
1500V AC @1 minute<br />
2000V AC @1 minute (model: M5VSH)<br />
AC power input<br />
Operational voltage range 85 – 264V<br />
DC power input Operational voltage range for 24V ±10%<br />
94 (3.70)<br />
3 (.12)<br />
7.3 (.29)<br />
1 2<br />
3 4<br />
5 6<br />
7 8<br />
8–M3.5 SCREW<br />
35.4 (1.39)<br />
25 (.98) 41 (1.61) [3.3 (.13)]<br />
DIN RAIL<br />
35mm wide<br />
• When mounting, no extra space is needed between units.<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
Signal Conditioners<br />
Model Function Page<br />
M5SN Input Loop Powered Isolator P.185<br />
M5VS Signal Transmitter P.186<br />
M5MV Signal Transmitter (narrow span input) P.187<br />
M5VF Signal Transmitter (high speed response) P.188<br />
M5VSH Signal Transmitter (high dielectric strength) P.189<br />
M5TS Thermocouple Transmitter P.190<br />
M5RS RTD Transmitter P.192<br />
M5MS Potentiometer Transmitter P.193<br />
M5DY Current Loop Supply P.194<br />
M5PT PT Transmitter P.195<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Rack-mounted<br />
M5CT CT Transmitter P.196<br />
M5CTC CT Transmitter (clamp-on current sensor) P.198<br />
M5PA Frequency Transmitter P.200<br />
184<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
A<br />
202<br />
Low Profile Signal Splitters<br />
W5-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
W5 Series Dual Output Transmitters are designed to accept a wide variety of process<br />
signal input and provide a standard and non-standard DC output.<br />
◆◆<br />
Only 41 mm (1.61 in") deep modules can be<br />
installed anywhere, even behind the panel cover<br />
◆◆<br />
The W5 Series signal splitters provide two isolated<br />
DC outputs of independent ranges<br />
◆◆<br />
Standard DIN rail mounting<br />
◆◆<br />
2000V AC isolation<br />
◆◆<br />
Selectable power input 11–27 V DC, 85–264V AC,<br />
110V DC<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Construction<br />
Terminal block<br />
7.4 (.29)<br />
5–M3.5 SCREW<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
Connection<br />
Input<br />
Output & Power<br />
Housing material<br />
Isolation<br />
Operating temperature<br />
Mounting<br />
Dielectric strength<br />
AC power input<br />
DC power input<br />
M3.5 screw terminals (torque 0.8 N·m)<br />
M3 screw terminals (torque 0.8 N·m)<br />
Flame-resistant resin (black)<br />
Input to output 1 to output 2 to power<br />
-5 to +55°C (23 to 131°F)<br />
DIN rail<br />
2000V AC @1 minute (input to output 1 or<br />
output 2 to power to ground)<br />
1000V AC @1 minute (output 1 to output 2)<br />
Operational voltage range 85 – 264V<br />
Operational voltage range for 24V ±10%,<br />
11 – 27V, or 85 – 150V<br />
94 (3.70)<br />
3 (.12)<br />
1<br />
6<br />
7<br />
2<br />
8<br />
3<br />
9<br />
4<br />
10<br />
5<br />
11<br />
6 (.24)<br />
45 (1.77) 41 (1.61) [3.3 (.13)]<br />
6–M3 SCREW<br />
DIN RAIL<br />
35mm wide<br />
• When mounting, no extra space is needed between units.<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
Signal Conditioners<br />
Model Function Page<br />
W5VS Signal Transmitter P.203<br />
W5FV Signal Transmitter (field-configurable) P.204<br />
W5TS Thermocouple Transmitter P.206<br />
W5RS RTD Transmitter P.208<br />
W5MS Potentiometer Transmitter P.209<br />
W5DY Current Loop Supply P.210<br />
W5LCS Strain Gauge Transmitter P.211<br />
W5PA Frequency Transmitter P.212<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Rack-mounted<br />
202<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
A<br />
214<br />
Thin Profile<br />
M3-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
PC Programmable; “ONE-STEP CAL” Programming Without Needing a PC is also available.<br />
◆◆<br />
Easy and precise field configurable I/O ranges<br />
◆◆<br />
Enhanced PC Configurator Software<br />
◆◆<br />
1500V AC isolation<br />
◆◆<br />
18 mm (0.71”) thin profile DIN rail mounting<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Signal Conditioners<br />
Rack-mounted<br />
SPECIFICATIONS<br />
Construction<br />
Connection<br />
Housing material<br />
Isolation<br />
Calibration<br />
Status indicator LED<br />
Operating temperature<br />
Mounting<br />
Dielectric strength<br />
Power input<br />
AC<br />
DC<br />
Universal<br />
(M3DY)<br />
Front terminal access<br />
Removable terminal block<br />
Flame-resistant resin (gray)<br />
Input to output to power<br />
One-Step Cal<br />
Tri-color (green/amber/red) LED<br />
-25 to +65°C (-13 to +149°F)<br />
-25 to +60°C (-13 to +140°F) (M3LU2)<br />
Max. 55°C (131°F) for UL approval<br />
DIN rail<br />
AC powered (M3LU2, M3LU, M3DY):<br />
2000V AC @1 minute<br />
(input to output to power to ground)<br />
DC powered:<br />
1500V AC @1 minute<br />
(input to output or power to ground)<br />
500V @1 minute (output to power)<br />
Operational voltage range 85 – 264V AC<br />
(M3LU2, M3LU, M3LPA2)<br />
Operational voltage range 9 – 36V DC<br />
Operational voltage range 24V DC ±10% (M3LDY)<br />
AC: Operational voltage range 90 – 264V<br />
47 – 66 Hz<br />
DC: Operational voltage range 21.6 – 264V,<br />
24V ±10%<br />
Model Function Page<br />
M3LU2 Universal Transmitter (field- and PC-configurable) P.216<br />
M3LU Universal Transmitter (field- and PC-configurable) P.218<br />
M3LV Signal Transmitter (field- and PC-configurable) P.220<br />
M3LT<br />
Thermocouple Transmitter<br />
(field- and PC-configurable)<br />
P.222<br />
M3LR RTD Transmitter (field- and PC-configurable) P.224<br />
M3LM<br />
Potentiometer Transmitter<br />
(field- and PC-configurable)<br />
P.226<br />
M3LLC<br />
M3LDY<br />
Strain Gauge Transmitter<br />
(field- and PC-configurable)<br />
Current Loop Supply<br />
(linearizing; field- and PC-configurable)<br />
P.227<br />
P.228<br />
M3DY Current Loop Supply P.230<br />
M3LPA2 Frequency Transmitter (field- and PC-configurable) P.232<br />
EXTERNAL DIMENSIONS<br />
106 (4.17)<br />
10 11 12<br />
7 8 9<br />
1 2 3<br />
4 5 6<br />
62 (2.44)<br />
18 (.71) 110.5 (4.35)<br />
[5 (.20)]<br />
• When mounting, no extra space is needed between units.<br />
mm (inch)<br />
DIN RAIL<br />
35mm wide<br />
214<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Thin Profile M3-UNIT Series<br />
A<br />
215<br />
Signal Conditioners<br />
n “ONE-STEP CAL” Configuration<br />
Both input type & range and output type & range are totally independent to each<br />
other, which makes the calibration easier and quicker than ever.<br />
Simply by pushing the front control buttons, “ONE-STEP CAL” programming is<br />
possible without requiring personnel to have any special knowledge to do so.<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
LED<br />
The front LED’s colors and flashing patterns help you<br />
easily identify the transmitter’s status and confirm the<br />
setup actions in each step of Calibration Modes.<br />
MODE Button<br />
UP Button<br />
DOWN Button<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
n Enhanced PC Configurator Software<br />
When you need to apply the same setting to multiple transmitters, downloading<br />
one setting from the PC is convenient. The PC Configurator software is available to<br />
download at M-<strong>System</strong> web site.<br />
M3 PC Configurator is packed with advanced features such as:<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
• Parameter setting is easily configured with a help of bargraphs on the screen.<br />
• Trend graph monitoring is also possible.<br />
• Fixed analog output can be set and provided for simulation<br />
when conducting a loop test.<br />
• 128-point linearization and custom thermocouple/RTD tables<br />
• Fine calibration<br />
• Save configuration files<br />
• Input filter<br />
• Diagnostics<br />
Sensor Information with Trend Graph Analog Output Calibration File Management (Compare)<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
Signal Conditioners<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
n EXTERNAL VIEW<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
■ FRONT VIEW<br />
LED1 (LD1)<br />
■ SIDE VIEW<br />
H-UNIT Series<br />
10 11 12<br />
7 8 9<br />
LED2 (LD2)<br />
LED3 (LD3)<br />
Configuration DIP SW<br />
MODE Button<br />
UP Button<br />
DOWN Button<br />
Configurator Jack<br />
4321<br />
OFF<br />
ON<br />
SW1<br />
SW2<br />
Rack-mounted<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
8 7654321<br />
OFF<br />
SW3<br />
ON<br />
4 5 6<br />
432 1<br />
OFF<br />
ON<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
215
A<br />
234<br />
Thin Profile<br />
M3S-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Universal AC/DC power input models available.<br />
◆◆<br />
Super-space-saving 12mm (0.47") width<br />
◆◆<br />
Universal AC/DC power input available<br />
◆◆<br />
PC programmable models available<br />
◆◆<br />
DC input model with optional fast response time<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
Construction<br />
Front terminal access<br />
Connection<br />
Removable terminal block<br />
Housing material Flame-resistant resin (gray)<br />
Isolation<br />
Input to output to power/<br />
Input to output 1 to output 2 to power<br />
Operating temperature -10 to +55°C (14 to 131°F)<br />
Mounting<br />
DIN rail<br />
Dielectric strength<br />
2000V AC @1 minute<br />
(input to output to power to ground)<br />
AC Operational voltage range 90 – 264V<br />
Power input<br />
DC Operational voltage range 24V DC ±10%,<br />
Universal<br />
AC: Operational voltage range 90 – 264 V AC<br />
DC: Operational voltage range 21.6 – 264 V DC<br />
106 (4.17)<br />
7 8<br />
5 6<br />
1 2<br />
3 4<br />
12<br />
(.47)<br />
62 (2.44)<br />
110.5 (4.35)<br />
[5 (.20)]<br />
DIN RAIL<br />
35mm wide<br />
• When mounting, no extra space is needed between units.<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
Signal Conditioners<br />
Model Function Page<br />
M3SYV Isolator P.235<br />
M3SXV Signal Transmitter (PC programmable) P.236<br />
M3SVS Signal Transmitter P.237<br />
M3SWVS Signal Transmitter (two isolated outputs) P.238<br />
M3SXT Thermocouple Transmitter (PC programmable) P.239<br />
M3SXR RTD Transmitter (PC programmable) P.240<br />
M3SRS RTD Transmitter P.241<br />
M3SXM Potentiometer Transmitter (PC programmable) P.242<br />
M3SMS Potentiometer Transmitter P.243<br />
M3SDY Current Loop Supply P.244<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Rack-mounted<br />
234<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
A<br />
246<br />
Hybrid IC Isolation Amplifiers<br />
20 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Isolation amplifiers provide signal and power isolation for data acquisition components to<br />
protect them from noises present at remote devices.<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Signal Conditioners<br />
Product Selection Guide<br />
Model<br />
20VS1A<br />
Function<br />
Isolation Amplifier (high speed response, 3-port isolation)<br />
Model<br />
20VS5-150<br />
Function<br />
Isolation Amplifier (input isolation)<br />
20VS2-1<br />
Isolation Amplifier (input isolation)<br />
20VS5-140<br />
Isolation Amplifier (output isolation)<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
Signal Conditioners<br />
20VS2-2<br />
20VS2-3<br />
20VS2-4<br />
20VS2-01<br />
20VS2-02<br />
20VS3<br />
20VS4-384<br />
20VS5-100<br />
Isolation Amplifier (output isolation)<br />
Isolation Amplifier (input isolation for narrow span)<br />
Isolation Amplifier (output isolation, current output)<br />
Isolation Amplifier (3-port isolation)<br />
Isolation Amplifier (3-port isolation)<br />
Isolation Amplifier (3-port isolation)<br />
Isolation Amplifier (5 kV input isolation)<br />
Isolation Amplifier (bidirectional amplifier)<br />
20VS5-170<br />
20VS5-200<br />
20VS5-500<br />
20VS8-210<br />
20VF-1<br />
20VF-2<br />
Isolation Amplifier (output isolation, for current output)<br />
Isolation Amplifier<br />
(input isolation, ultra-high speed response)<br />
Isolation Amplifier (5 kV input isolation)<br />
Isolation Amplifier (high speed response, 3-port isolation)<br />
Isolation Amplifier<br />
(input isolation, ultra-high speed response)<br />
Isolation Amplifier<br />
(output isolation, ultra-high speed response)<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
20VS1A<br />
20VS2-x<br />
20VS2-0x<br />
20VS3<br />
20VS4-384<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Rack-mounted<br />
20VS5-100, 150, 140 20VS5-170 20VS5-200 20VS5-500<br />
20VS8-210<br />
20VF-x<br />
246<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Hybrid IC Isolation Amplifiers 20 Series<br />
A<br />
247<br />
Signal Conditioners<br />
SPECIFICATIONS<br />
◆ 2-port Isolation<br />
■ Input Isolation<br />
Model Features Input Output<br />
Response Time<br />
(0 – 90 %)<br />
Freq.<br />
Characteristics<br />
Power<br />
Input<br />
20VF-1 Ultra-high speed response -10 – +10V DC -10 – +10V DC ≤ 80 μsec. Approx. 5 kHz, -3 dB 15V DC<br />
20VS2-1 Built in surge protectors -10 – +10V DC -10 – +10V DC ≤ 450 μsec. Approx. 1 kHz, -3 dB 15V DC<br />
Dimensions<br />
mm (inch)<br />
W49 × H14.5 × D18<br />
(1.93” × 0.57” × 0.71”)<br />
W49 × H14.5 × D18<br />
(1.93” × 0.57” × 0.71”)<br />
20VS2-3 Narrow span<br />
-10 – +100mV DC<br />
≤ 200 msec. Approx. 2 Hz, -3 dB<br />
0 – 10V DC<br />
15V DC<br />
W49 × H14.5 × D18<br />
0 – 5V DC ≤ 450 μsec. Approx. 1 kHz, -3 dB<br />
(1.93” × 0.57” × 0.71”)<br />
20VS4-384 Up to 5 kV input isolation -5 – +5 V DC -5 – +5 V DC ≤ 450 μsec. 1 kHz, -3 dB 15V DC<br />
W38 × H15.2 × D38<br />
(1.50” × 0.60” × 1.50”))<br />
• Small installation area in<br />
@ 15 V power<br />
20VS5-150<br />
printed wiring board -7 – +7 V DC -7 – +7 V DC<br />
≤ 90 μsec. Approx. 5 kHz, -3 dB 15V DC<br />
W53 × H24 × D18<br />
• Gain adjustable range,<br />
@ 11.5 V power<br />
(2.09” × 0.94” × 0.71”)<br />
× 1 to × 100<br />
-5 – +5 V DC -5 – +5 V DC<br />
20VS5-200 Ultra-high speed response -5 – +5 V DC -5 – +5 V DC ≤ 10 μsec. Approx. 50 kHz, -3 dB 15V DC<br />
W48 × H15 × D9.5<br />
(1.89” × 0.59” × 0.37”)<br />
20VS5-500 Up to 5 kV input isolation -5 – +5 V DC -5 – +5 V DC ≤ 90 μsec. 5 kHz, -3 dB TYP. 15V DC<br />
W38 × H15.2 × D38<br />
(1.50” × 0.60” × 1.50”)<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
■ Output Isolation<br />
Model Features Input Output<br />
Response Time<br />
(0 – 90 %)<br />
Freq.<br />
Characteristics<br />
Power<br />
Input<br />
20VF-2 Ultra-high speed response -10 – +10V DC -10 – +10V DC ≤ 80 μsec. Approx. 5 kHz, -3 dB 15V DC<br />
20VS2-2 Built in surge protectors -10 – +10V DC -10 – +10V DC ≤ 450 μsec. Approx. 1 kHz, -3 dB 15V DC<br />
0 – 20mA DC<br />
20VS2-4 Voltage and current output 0 – 5V DC<br />
0 – 10V DC<br />
@ 15 V power<br />
20VS5-140<br />
Small installation area in -7 – +7 V DC -7 – +7 V DC<br />
printed wiring board<br />
@ 11.5 V power<br />
-5 – +5 V DC -5 – +5 V DC<br />
≤ 2 msec. Approx. 200 Hz, -3 dB 15V DC<br />
≤ 90 μsec. Approx. 5 kHz, -3 dB 15V DC<br />
20VS5-170 Current output 0 – 5 V DC 0 – 20 mA DC ≤ 1 msec. Approx. 500 Hz, -3 dB 12V DC<br />
■ Bidirectional Isolation<br />
Model Features Input Output<br />
20VS5-100<br />
◆ 3-port Isolation<br />
• Small installation area in<br />
printed wiring board<br />
• Bidirectional amplifier<br />
@ 15 V power<br />
-7 – +7 V DC -7 – +7 V DC<br />
@ 11.5 V power<br />
-5 – +5 V DC -5 – +5 V DC<br />
Model Features Input Output<br />
Response Time<br />
(0 – 90 %)<br />
Freq.<br />
Characteristics<br />
Power<br />
Input<br />
≤ 90 μsec. Approx. 5 kHz, -3 dB 15V DC<br />
Response Time<br />
(0 – 90 %)<br />
Freq.<br />
Characteristics<br />
Power<br />
Input<br />
20VS1A High speed response -10 – +10 V DC -10 – +10 V DC ≤ 50 μsec. Approx. 20 kHz, -3 dB 15V DC<br />
20VS2-01 High-linearity -5 – +5 V DC -5 – +5 V DC ≤ 390 μsec. Approx. 1 kHz, -3 dB 15V DC<br />
20VS2-02 High-linearity 0 – 5 V DC 0 – 5 V DC ≤ 390 μsec. Approx. 1 kHz, -3 dB 15V DC<br />
20VS3 Saving installation space -5 – +5V DC -5 – +5V DC ≤ 450 μsec. Approx. 1 kHz, -3 dB 15V DC<br />
20VS8-210 High speed response -10 – +10 V DC -10 – +10 V DC ≤ 50 μsec. Approx. 20 kHz, -3 dB 15V DC<br />
Dimensions<br />
mm (inch)<br />
W49 × H14.5 × D18<br />
(1.93” × 0.57” × 0.71”)<br />
W49 × H14.5 × D18<br />
(1.93” × 0.57” × 0.71”)<br />
W49 × H14.5 × D18<br />
(1.93” × 0.57” × 0.71”)<br />
W53 × H24 × D18<br />
(2.09” × 0.94” × 0.71”)<br />
W44 × H10.5 × D18<br />
(1.73” × 0.41” × 0.71”)<br />
Dimensions<br />
mm (inch)<br />
W53 × H24 × D18<br />
(2.09” × 0.94” × 0.71”)<br />
Dimensions<br />
mm (inch)<br />
W53.3 × H26 × D11.3<br />
(2.1” × 1.02” × 0.44”)<br />
W33 × H8 × D19<br />
(1.30” × 0.31” × 0.75”)<br />
W33 × H8 × D19<br />
(1.30” × 0.31” × 0.75”)<br />
W33 × H19 × D8<br />
(1.30” × 0.75” × 0.31”)<br />
W53.3 × H9.8 × D25.4<br />
(2.1” × 0.39” × 1”)<br />
Signal Conditioners<br />
Product Selection Guide<br />
Signal Conditioners<br />
Rack-mounted<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
247
248A<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Other Signal Conditioners<br />
Pico-M/ MX-UNIT/ M-UNIT/<br />
W-UNIT/ K-UNIT/ F-UNIT Series<br />
Dual Output Super-mini Signal Conditioners<br />
Pico-M Series<br />
Wide Variety of I/O Modules<br />
◆◆Ultra-small size thanks to surface-mounted components<br />
with low heat generating design<br />
◆◆4-way isolation<br />
◆◆Continuously selectable input ranges<br />
◆◆4–20mA 2nd output available<br />
Plug-in Front Configurable<br />
MX-UNIT Series<br />
Field Configurable<br />
◆◆Local LED display indicates input in engineering unit<br />
◆◆The display helps programming with the front ITEM/<br />
DATA buttons.<br />
◆◆2000V AC isolation<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Plug-in<br />
M-UNIT Series<br />
Plug-in Signal Splitters<br />
W-UNIT Series<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Plug-in type<br />
◆◆LCD display optional<br />
◆◆2000V AC isolation<br />
Plug-in signal splitters<br />
◆◆Two independent output ranges can be specified.<br />
◆◆2000V AC isolation<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
Signal Conditioners<br />
Plug-in<br />
K-UNIT Series<br />
Space-saving Plug-in<br />
F-UNIT Series<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
Plug-in type<br />
◆◆Low cost<br />
◆◆Wide selection of power transducers<br />
Space-saving type<br />
◆◆Zero & span adjustments behind access door<br />
H-UNIT Series<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
Rack-mounted<br />
248<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Other Signal Conditioners<br />
H-UNIT/ 10-RACK/ 18-RACK/<br />
38-RACK Series and Others<br />
Space-saving Plug-in<br />
H-UNIT Series<br />
Space-saving type<br />
◆◆Pneumatic transducers available<br />
Dual Output<br />
10-RACK Series<br />
One-input, two isolated outputs<br />
◆◆Up to 16 units in 19-inch rack<br />
◆◆Optional 40-pin connector for outputs<br />
◆◆Direct interface to Various DCS via connector<br />
A249<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
DCS Front End<br />
18-RACK Series<br />
Connectors compatible to various DCS<br />
◆◆Up to 16 units in 19-inch rack<br />
◆◆Direct interface to Various DCS via connector<br />
◆◆Dual outputs standard<br />
Interposing Relays<br />
38-RACK Series<br />
Greatly simplifies designing, installation, wiring and<br />
testing of interposing relays.<br />
◆◆Complete packaging for interposing relays<br />
◆◆Plug to plug connection controller<br />
◆◆I/O simulator function<br />
Signal Conditioners<br />
Product Selection Guide<br />
Mini-M Series<br />
Mini-MW Series<br />
M6 Series<br />
M5-UNIT Series<br />
W5-UNIT Series<br />
DC Power Supply<br />
model: MDC5 / MDC6 / MDC7<br />
Signal Conditioners<br />
M3-UNIT Series<br />
M3S-UNIT Series<br />
20 Series<br />
Pico-M Series<br />
MX-UNIT Series<br />
◆◆Accepts 100–240V AC and provides regulated<br />
24V DC output (60W / 120W / 240W)<br />
◆◆Maintenance forecast monitor function<br />
M-UNIT Series<br />
W-UNIT Series<br />
K-UNIT Series<br />
F-UNIT Series<br />
H-UNIT Series<br />
Rack-mounted<br />
10-RACK Series<br />
18-RACK Series<br />
38-RACK Series<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
249
Two-wire Signal Conditioners<br />
High performance transmitters in<br />
various housing styles<br />
Head-mount, Field-mount and DIN rail mount transmitters are available<br />
for various classified/non-classified environments.<br />
Two-wire isolators draw power from the 4 – 20mA process signal loop,<br />
no additional power supply or lines is required which can save on<br />
wiring costs.<br />
ISP ’12<br />
251
B<br />
Signal Conditioners<br />
252 Two-wire Signal Conditioners Product Selection Guide<br />
Two-wire Signal Conditioners Product Selection Guide<br />
B253<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Head-mount, Programmable<br />
27-UNIT Series<br />
Head-mount<br />
26-UNIT Series<br />
Field-mount<br />
B6-UNIT Series<br />
DIN Rail Mount<br />
B3-UNIT Series<br />
Low Profile<br />
B5-UNIT Series<br />
Hockey-puck Style<br />
6-UNIT Series<br />
Compact Size<br />
T-UNIT Series<br />
Space-saving, Plug-in<br />
B-UNIT Series<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
6BX-E<br />
Power Transducers<br />
Indicators<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
P.254 P.266 P.272 P.278 P.290<br />
Construction Sensor head-mounting Sensor head-mounting Outdoor enclosure (IP65) Front terminal access Terminal block Hockey-puck style<br />
Stand-alone; terminal access<br />
at the front<br />
Plug-in<br />
Connection M3 screw terminal Terminal block M3.5 screw terminal Removable terminal block M3.5 screw terminal M3 screw terminal DIN terminal block M3.5 screw terminal<br />
Isolation Input to output Input to output<br />
Input to output to<br />
outdoor enclosure<br />
Input to output Input to output Input to output Input to output Input to output<br />
Dielectric Strength 1500V AC 1500V AC 1500V AC 2000V AC 2000V AC 500V AC 500V AC 500V AC<br />
Range Selectability PC or HART programming Specified when ordering HART (PC) programming<br />
Operating Temperature<br />
Mounting<br />
Dimensions<br />
Standards & Approvals<br />
-40 to +85°C<br />
(-40 to +185°F)<br />
Head mount or<br />
Field mount<br />
44 dia. × 20.7 mm<br />
(1.732 dia. × 0.81”)<br />
CE / ATEX / FM /<br />
SIL2, RoHS for selected models<br />
-40 to +85°C<br />
(-40 to +185°F)<br />
-40 to +85°C<br />
(-40 to +185°F)<br />
Specified when ordering or<br />
HART (PC) / PROFIBUS-PA (PC)<br />
/ DIP switch programming<br />
-40 to +85°C<br />
(-40 to +185°F)<br />
Specified when ordering<br />
-40 to +80°C<br />
(-40 to +176°F)<br />
Head mount Field mount DIN rail DIN rail<br />
43.5 dia. × 26.5 mm<br />
(1.71 dia. × 1.04”)<br />
CE / ATEX for selected models /<br />
RoHS<br />
110 (4.33”) dia.<br />
CE / ATEX / FM / SIL<br />
W18 × H106 × D110.5 mm<br />
(0.71” × 4.17” × 4.35”)<br />
CE / UL / C-UL /<br />
ATEX, FM, RoHS for selected models<br />
W25 × H97 × D41 mm<br />
(0.98” × 3.82” × 1.61”)<br />
Specified when ordering or<br />
DIP switch programming<br />
-5 to +70°C<br />
(23 to 158°F)<br />
DIN rail<br />
with mounting plate A-31<br />
W76 × H52.5 × D61 mm<br />
(2.99” × 2.07” × 2.40”)<br />
Specified when ordering<br />
-5 to +60°C<br />
(23 to 140°F)<br />
Surface or DIN rail<br />
W25 × H60 × D70 mm<br />
(0.98” × 2.36” × 2.76”)<br />
Specified when ordering<br />
-5 to +55°C<br />
(23 to 131°F)<br />
Surface or DIN rail<br />
W26 × H93 × D137 mm<br />
(1.02” × 3.66” × 5.39”)<br />
CE / RoHS – – CE for selected models<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Two-wire<br />
Product Selection Guide<br />
27-UNIT Series<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
B-UNIT Series<br />
Two-wire Signal Conditioners<br />
27-UNIT 26-UNIT B6-UNIT B3-UNIT B5-UNIT 6-UNIT T-UNIT B-UNIT<br />
Input Loop Powered Isolator – – – – B5SN 6SN TSN BSN<br />
DC Input – – –<br />
B3VS/1 (single channel)<br />
B3VS/2 (dual channel)<br />
B5VS – TV, TVS BV, BVS<br />
DC Input<br />
(programmable)<br />
– – – B3FV – 6VS – –<br />
Universal Temperature Input<br />
(HART, outdoor enclosure)<br />
27HU-B – B6U-B – – – – –<br />
Universal Temperature Input<br />
(HART)<br />
27HU – B6U B3HU – – – –<br />
Universal Temperature Input<br />
(PROFIBUS-PA)<br />
– – – B3PU – – – –<br />
Universal Temperature Input 27U – – – – – – –<br />
Thermocouple Input – 26TS1 – – B5TS 6TS – BT, BTS<br />
Thermocouple Input<br />
(programmable)<br />
27TS – – B3FT – 6TS1 – –<br />
RTD Input – 26REX, 26R1, 26RS – – B5RS – TR BR<br />
RTD Input<br />
(programmable)<br />
27R, 27RS – – B3FR – 6R – –<br />
Potentiometer Input 27PM – – – B5MS 6M TM BM<br />
Strain Gauge Input – – – – – 6LC – BLC<br />
Frequency Input – – – – – – – BSP<br />
Frequency Input<br />
(programmable)<br />
– – – B3FP – 6PA – –<br />
Square Root Extractor – – – – – 6FN – –<br />
AC Input – – – – – 6AC – –<br />
PT Input – – – – – 6PT – BPT<br />
CT Input – – – – – 6CT – BCT<br />
P/I Transducer – – – – – – TPV BPV<br />
Two-wire<br />
Product Selection Guide<br />
Two-wire Signal Conditioners<br />
27-UNIT Series<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
B-UNIT Series<br />
252<br />
Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
253
B<br />
Signal Conditioners<br />
254<br />
Head-mounted Two-wire Signal Conditioners<br />
27-UNIT Series<br />
SIL2<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
I/O range programming via PC Configurator<br />
HART communication capability. ATEX and FM approval<br />
◆◆<br />
Function monitor LED optional (27R, 27RS)<br />
◆◆<br />
HART programmable (27HU, 27HU-B)<br />
◆◆<br />
4-digit LED indicator optional (27HU-B)<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
SPECIFICATIONS SPECIFICATIONS (Model: 27HU-B)<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Two-wire<br />
Product Selection Guide<br />
27-UNIT Series<br />
Construction<br />
Sensor head-mounting<br />
Connection<br />
M3 screw terminals<br />
(nickel-plated brass; torque 0.5 N·m)<br />
Housing material Flame-resistant resin (black)<br />
Isolation<br />
Input to output<br />
Cold junction compensation CJC sensor incorporated<br />
Self diagnostics<br />
Detects internal error, burnout<br />
Mounting<br />
Head-mounting (DIN type B head)<br />
Supply voltage<br />
9 – 35V DC (non-approved)<br />
Dielectric strength 1500V AC @1 minute (input to output)<br />
EXTERNAL DIMENSIONS<br />
Construction<br />
Degree of protection<br />
Transmitter material<br />
• Housing<br />
• Electrical connection<br />
Indicator material<br />
• Housing<br />
• Electrical connection<br />
Enclosure material<br />
Outdoor enclosure<br />
NEMA 4X, IP65<br />
Flame-resistant resin (black)<br />
M3 screw terminals<br />
(nickel-plated brass; torque 0.5 N·m)<br />
Flame-resistant resin (black)<br />
Terminal block<br />
Diecast aluminium standard; stainless steel casting<br />
optional (equivalent to type 316); silver color,<br />
epoxy resin coated<br />
Mounting bracket assembly Stainless steel 304<br />
Applicable pipe<br />
1 1/2” min.; 2” max.<br />
Isolation<br />
Input to output to outdoor enclosure<br />
Please consult M-system for RoHS compliance.<br />
mm (inch)<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
Two-wire Signal Conditioners<br />
27xx<br />
2–4.5 (.18) dia.<br />
MTG HOLE<br />
+<br />
44 (1.73) dia.<br />
33 (1.30) 6 (.24) dia.<br />
16.5 (.65)<br />
1 4<br />
2<br />
3<br />
–<br />
6.3<br />
(.25)<br />
20.7 (.81)<br />
19.5 (.77)<br />
12.7 (.5)<br />
27HU-B<br />
174 (6.85)<br />
78 (3.07) max.<br />
114 (4.49)<br />
110 (4.33)<br />
78 (3.07) max.<br />
39 (1.54) dia.<br />
2–G 1/2 or 1/2NPT or<br />
M20x1.5 or PG13.5<br />
110 (4.33) dia.<br />
19 (.75)<br />
B-UNIT Series<br />
6–M3 SCREW<br />
■■Field-mounted Transmitters<br />
Model Function Page<br />
27HU-B<br />
2-wire Universal Temperature Transmitter<br />
(HART communication, outdoor enclosure,<br />
explosion-proof)<br />
P.255<br />
■■Head-mounting Transmitters<br />
Model Function Page<br />
27HU<br />
27U<br />
2-wire Universal Temperature Transmitter<br />
(HART communication)<br />
2-wire Universal Temperature Transmitter<br />
(PC programmable)<br />
P.258<br />
P.260<br />
27TS Thermocouple Transmitter (PC programmable) P.262<br />
27R RTD Transmitter (PC programmable; non-isolated) P.263<br />
27RS RTD Transmitter (PC programmable) P.264<br />
27PM Potentiometer Transmitter (PC programmable) P.265<br />
■■Accessories, Related Products<br />
Model Function Page<br />
A-6 Mounting Spacer ***<br />
A-34 DIN Rail Mounting Adaptor ***<br />
6DV 4-digit Loop Powered Indicator (intrinsically safe) P.416<br />
6DVI 4-digit Loop Powered Indicator (intrinsically safe) P.417<br />
6BX-E Outdoor Enclosure ***<br />
COP-H Bell202 Modem (RS-232C interface) ***<br />
COP-HU Bell202 Modem (USB interface) ***<br />
M2DYH2 Current Loop Supply (applicable to HART signal) P.054<br />
M2DYHR Current Repeater (applicable to HART signal) P.056<br />
W2DYH Current Loop Supply (applicable to HART signal) P.129<br />
A3DYH Current Loop Supply (applicable to HART signal) ***<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
254<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
266B<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
Head-mounted Two-wire Signal Conditioners<br />
26-UNIT Series<br />
Accepts direct input from RTD or T/C and provides a standard 4 – 20mA DC signal<br />
◆◆<br />
Suitable for DIN B type head<br />
◆◆<br />
Linearization, burnout protection, cold junction<br />
compensation (T/C input) standard<br />
◆◆<br />
Optional 25 msec. response time selectable for<br />
26TS1 and 26RS<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Two-wire<br />
Product Selection Guide<br />
Construction<br />
Connection<br />
Housing material<br />
Mounting<br />
Supply voltage<br />
Operating temperature<br />
Operating humidity<br />
Sensor head-mounting<br />
Terminal block<br />
Flame-resistant resin (black)<br />
Head-mounting (DIN type B head)<br />
12 – 30V DC<br />
-40 to +80°C (-40 to +176°F)<br />
0 to 90% RH (non-condensing)<br />
26REX<br />
ZERO ADJ.<br />
SPAN ADJ.<br />
2–4.2 (.17) dia. MTG HOLE<br />
1<br />
43.5 (1.71) dia.<br />
33 (1.30)<br />
2<br />
3<br />
4<br />
5<br />
7.0 (.28) dia.<br />
26.5 (1.04)<br />
15.5 (.61)<br />
27-UNIT Series<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
B-UNIT Series<br />
Two-wire Signal Conditioners<br />
Model Function Page<br />
26TS1 Thermocouple Transmitter (isolated) P.267<br />
26REX RTD Transmitter (intrinsically safe) P.268<br />
26R1 RTD Transmitter (non-isolated) P.269<br />
26RS RTD Transmitter (isolated) P.270<br />
■■Accessories, Related Products<br />
Model Function Page<br />
A-6 Mounting Spacer ***<br />
A-34 DIN Rail Mounting Adaptor ***<br />
6DV 4-digit Loop Powered Indicator (intrinsically safe) P.416<br />
6DVI 4-digit Loop Powered Indicator (intrinsically safe) P.417<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
266<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
B<br />
272<br />
Field-mounted Two-wire Signal Conditioners<br />
B6-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
M-<strong>System</strong>’s Models B6U and B6U-B accept a wide variety of inputs including<br />
thermocouples and RTDs as well as mV, resistance and potentiometer sensor types.<br />
◆◆<br />
Plug-in two-line LCD display<br />
◆◆<br />
HART programmable<br />
◆◆<br />
AMS software version 6.0 or higher<br />
◆◆<br />
Stainless steel enclosure optional<br />
◆◆<br />
ATEX Zone 0 approvals<br />
◆◆<br />
FM Class I, II, III, Division 1 approvals<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Two-wire<br />
Product Selection Guide<br />
27-UNIT Series<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
B-UNIT Series<br />
Two-wire Signal Conditioners<br />
SPECIFICATIONS (Model: B6U) SPECIFICATIONS (Model: B6U-B)<br />
HART communication, intrinsically safe<br />
Electrical connection M3.5 screw terminals (torque 0.8 N·m)<br />
Materials<br />
• Transmitter housing Flame-resistant resin (black)<br />
• Screw terminals Nickel-plated brass<br />
Isolation<br />
Input to output<br />
HART communication, intrinsically safe/explosion-proof<br />
Construction<br />
Outdoor enclosure<br />
Degree of protection NEMA 4X, IP66 / IP67<br />
Wiring conduit G 1/2, 1/2 NPT, M20 × 1.5, PG 13.5<br />
Electrical connection M3.5 screw terminals (torque 0.8 N·m)<br />
Materials<br />
• Transmitter housing Flame-resistant resin (black)<br />
• Screw terminals Nickel-plated brass<br />
• Enclosure material Diecast aluminium standard; stainless steel<br />
casting optional (equivalent to type 316); silver<br />
color, epoxy resin coated<br />
• Mounting bracket assembly Stainless steel 304<br />
Applicable pipe<br />
1 1/2” min.; 2” max.<br />
Isolation<br />
Input to output to outdoor enclosure<br />
EXTERNAL DIMENSIONS (Model: B6U) mm (inch) EXTERNAL DIMENSIONS (Model: B6U-B) mm (inch)<br />
59 (2.32) dia.<br />
33 (1.30)<br />
1 2 3 4<br />
1 2 3<br />
–<br />
Without LCD Module<br />
(Terminal Assignments)<br />
+<br />
4<br />
63 (2.48) max.<br />
2–5 (.197) dia. MTG HOLE<br />
24.5 (.965) deep<br />
LCD MODULE CONNECTOR<br />
HHC TERMINAL<br />
With LCD Module<br />
27.5 (1.08) 24.5 (.96)<br />
48 (1.89)<br />
34.5 (1.36)<br />
Leave enough space at both sides of the module to reach<br />
the side levers when installing/removing the LCD module.<br />
174 (6.85)<br />
78 (3.07) max.<br />
114 (4.49)<br />
110 (4.33)<br />
78 (3.07) max.<br />
39 (1.54) dia.<br />
2–G 1/2 or 1/2NPT or<br />
M20x1.5 or PG13.5<br />
110 (4.33) dia.<br />
*Two sets of cable gland are attached with TIIS flameproof option.<br />
19 (.75)<br />
Model Function Page<br />
B6U-B<br />
2-wire Universal Temperature Transmitter<br />
(HART communication,<br />
intrinsically safe/explosion-proof)<br />
P.273<br />
B6U<br />
2-wire Universal Temperature Transmitter<br />
(HART communication, intrinsically safe)<br />
P.276<br />
■■Accessories, Related Products<br />
Model Function Page<br />
A-34 DIN Rail Mounting Adaptor ***<br />
COP-H Bell202 Modem (RS-232C interface) ***<br />
COP-HU Bell202 Modem (USB interface) ***<br />
M2DYH2 Current Loop Supply (applicable to HART signal) P.054<br />
M2DYHR Current Repeater (applicable to HART signal) P.056<br />
W2DYH Current Loop Supply (applicable to HART signal) P.129<br />
A3DYH Current Loop Supply (applicable to HART signal) ***<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
272<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
B<br />
Signal Conditioners<br />
278<br />
Space-saving Two-wire Signal Conditioners<br />
B3-UNIT Series<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
DIN rail mounted, input configurable two-wire transmitters.<br />
◆◆<br />
Input type and range selectable with the internal<br />
DIP switches and fine calibration using the front<br />
potentiometers<br />
◆◆<br />
Wide supply voltage range 12–45V DC<br />
◆◆<br />
Eliminates noise and prevents ground loops with<br />
2000V AC isolation<br />
◆◆<br />
B3HU / B3PU 1500V AC isolation between input<br />
and output<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Two-wire<br />
Product Selection Guide<br />
27-UNIT Series<br />
GENERAL SPECIFICATIONS<br />
Construction<br />
Front terminal access<br />
Connection<br />
Removable terminal block<br />
Housing material Flame-resistant resin (gray)<br />
Isolation<br />
Input to output<br />
INSTALLATION<br />
Supply voltage<br />
12 – 45V DC<br />
Operating temperature<br />
-40 to +85°C (-40 to +185°F)<br />
Max. 55°C (131°F) for UL approval<br />
Operating humidity 0 to 95% RH (non-condensing)<br />
Mounting<br />
DIN rail<br />
Dielectric strength 2000V AC @1 minute (input to output to ground)<br />
106 (4.17)<br />
10 11 12<br />
4 5 6<br />
62 (2.44)<br />
18 (.71) 110.5 (4.35)<br />
[3.3 (.13)]<br />
• When mounting, no extra space is needed between units.<br />
DIN RAIL<br />
35mm wide<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
B-UNIT Series<br />
Two-wire Signal Conditioners<br />
OUTPUT<br />
Output<br />
4 – 20mA DC<br />
Load resistance vs. supply voltage:<br />
Supply Voltage (V) – 12 (V)<br />
Load Resistance (Ω) = ––––––––––––––––––––<br />
0.02 (A)<br />
(including leadwire resistance)<br />
LOAD RESISTANCE [Ω]<br />
1650<br />
1600<br />
1400<br />
1200<br />
1000<br />
800<br />
600<br />
400<br />
200<br />
0<br />
10 12 20 30 40 45<br />
SUPPLY VOLTAGE [V]<br />
(600Ω maximum at 24V DC)<br />
Model Function Page<br />
B3HU<br />
2-wire Universal Temperature Transmitter (HART<br />
communication, intrinsically safe)<br />
P.280<br />
B3PU<br />
2-wire Universal Temperature Transmitter<br />
(PROFIBUS-PA)<br />
P.282<br />
B3FV Signal Transmitter (field-configurable) P.279<br />
B3VS/1<br />
Signal Transmitter (single-channel output loop<br />
powered isolator)<br />
P.284<br />
B3VS/2<br />
Signal Transmitter (dual-channel output loop<br />
powered isolator)<br />
P.285<br />
B3FT Thermocouple Transmitter (field-configurable) P.286<br />
B3FR RTD Transmitter (field-configurable) P.287<br />
B3FP Frequency Transmitter (field-configurable) P.288<br />
■■Accessories, Related Products<br />
Model Function Page<br />
COP-H Bell202 Modem (RS-232C interface) ***<br />
COP-HU Bell202 Modem (USB interface) ***<br />
M2DYH2 Current Loop Supply (applicable to HART signal) P.054<br />
M2DYHR Current Repeater (applicable to HART signal) P.056<br />
W2DYH Current Loop Supply (applicable to HART signal) P.129<br />
A3DYH Current Loop Supply (applicable to HART signal) ***<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
278<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
290B<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
Super-mini Two-wire Terminal Block<br />
Signal Conditioners<br />
B5-UNIT Series<br />
Only 41 mm (1.61 in.) deep modules can be installed anywhere, even behind the panel<br />
cover.<br />
◆◆<br />
41 mm (1.61”) deep<br />
◆◆<br />
Linearization, burnout protection, cold junction<br />
compensation (T/C input) standard<br />
◆◆<br />
Optional 25 msec. response time selectable<br />
◆◆<br />
Power indicator LED<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Two-wire<br />
Product Selection Guide<br />
27-UNIT Series<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
B-UNIT Series<br />
Two-wire Signal Conditioners<br />
GENERAL SPECIFICATIONS<br />
Construction<br />
Terminal block<br />
Connection<br />
M3.5 screw terminals<br />
(nickel-plated steel; torque 0.8 N·m)<br />
Housing material Flame-resistant resin (black)<br />
Isolation<br />
Input to output<br />
Power LED<br />
Orange light turns on when the power is<br />
supplied.<br />
INSTALLATION<br />
Supply voltage<br />
Operating temperature<br />
Operating humidity<br />
Mounting<br />
Dielectric strength<br />
OUTPUT<br />
Output<br />
4 – 20mA DC<br />
Load resistance vs. supply voltage:<br />
Supply Voltage (V) – 12 (V)<br />
Load Resistance (Ω) = ––––––––––––––––––––<br />
0.02 (A)<br />
(including leadwire resistance)<br />
12 – 28V DC<br />
-40 to +80°C (-40 to +176°F)<br />
0 to 90% RH (non-condensing)<br />
DIN rail<br />
2000V AC @1 minute (input to output to ground)<br />
LOAD RESISTANCE [Ω]<br />
800<br />
600<br />
400<br />
200<br />
0<br />
10 12 15 20 25 28<br />
SUPPLY VOLTAGE [V]<br />
(600Ω maximum at 24V DC)<br />
94 (3.70)<br />
3 (.12)<br />
1 2<br />
5 6<br />
7.3 (.29)<br />
3 4<br />
7 8<br />
8–M3.5 SCREW<br />
DIN RAIL<br />
35mm wide<br />
25 (.98) 41 (1.61) [3.3 (.13)]<br />
• When mounting, no extra space is needed between units.<br />
Model Function Page<br />
B5SN Input Loop Powered Isolator P.291<br />
B5VS Signal Transmitter P.292<br />
B5TS Thermocouple Transmitter P.293<br />
B5RS RTD Transmitter P.294<br />
B5MS Potentiometer Transmitter P.295<br />
290<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
B<br />
296 Other Two-wire Signal Conditioners<br />
6-UNIT/ T-UNIT/ B-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
Field-mounted Two-wire Signal Conditioners<br />
6-UNIT Series<br />
Field-selectable input, Hockey-puck style<br />
◆◆Field-selectable input types via internal DIP switches<br />
◆◆Rugged metal housing provides increased noise &<br />
RFI protection<br />
◆◆Outdoor enclosure 6BX-E available<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Two-wire<br />
Product Selection Guide<br />
27-UNIT Series<br />
Super-mini Two-wire Signal Conditioners<br />
T-UNIT Series<br />
Ultra-high density mounting on wall/DIN rail<br />
◆◆Front DIN screw terminals<br />
◆◆Super-small pneumatic-to-current transducer<br />
available<br />
◆◆Zero/span adjustments<br />
Space-saving Two-wire Signal Conditioners<br />
B-UNIT Series<br />
Space-saving type<br />
◆◆Wide supply voltage range 12–60V DC<br />
26-UNIT Series<br />
B6-UNIT Series<br />
B3-UNIT Series<br />
B5-UNIT Series<br />
6-UNIT Series<br />
T-UNIT Series<br />
Two-wire Signal Conditioners<br />
B-UNIT Series<br />
296<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Power Transducers<br />
Measuring most electrical parameters<br />
Wide range of power measuring transducers – including AC volts, AC current,<br />
power factor, watts, vars and phase angles measurements. Multi power monitor<br />
has output options – Modbus, CC-Link, LONWORKS, Ao, Do.<br />
ISP ’12<br />
297
C<br />
298 Power Transducers Products Selection Guide<br />
Power Transducers Products Selection Guide<br />
C<br />
299<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
M4 Screw Connection<br />
LT-UNIT Series<br />
M3.5 Screw Connection<br />
L-UNIT Series<br />
Plug-in<br />
K-UNIT Series<br />
Multi Power Monitor<br />
53U<br />
Multi Power Monitor<br />
54U / 54UC / 54UL<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
P.300<br />
Construction Terminal access at the front Terminal access at the front Plug-in<br />
Connection M4 screw terminal M3.5 screw terminal M3.5 screw terminal<br />
Dielectric Strength 2000V AC 2000V AC 2000V AC<br />
Auxiliary Power AC / DC AC / DC AC / DC<br />
Self Powered Type Available Available Available<br />
Operating Temperature<br />
-10 to +55°C<br />
-10 to +55°C<br />
-10 to +55°C<br />
(14 to 131°F)<br />
(14 to 131°F)<br />
(14 to 131°F)<br />
Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail<br />
Dimensions<br />
W39 [72] × H111 × D143 mm W75 × H80 × D112 mm W50 [72] × H80 × D123 [132] mm<br />
(1.54” [2.83] × 4.37” × 5.63”)<br />
(2.95” × 3.15” × 4.41”) (1.97” [5.20”] × 3.15” × 4.84” [2.83”])<br />
IEC 60688 Yes – –<br />
Standards & Approvals CE / RoHS for selected models RoHS for selected models RoHS for selected models<br />
P.328 P.329<br />
Construction 96-mm square (1/4 DIN size) 110-mm square panel flush mounted<br />
Connection;<br />
Voltage input<br />
Connector type terminal block<br />
M4 screw terminals (torque 1.4 N·m)<br />
Dielectric Strength 2500V AC 2000 V AC @ 1 minute<br />
Auxiliary Power AC / DC (universal) AC / DC (universal)<br />
Operating Temperature<br />
-10 to +55°C<br />
-10 to +55°C<br />
(14 to 131°F)<br />
(14 to 131°F)<br />
Mounting Panel Flush Mounting Panel flush mounting<br />
Dimensions<br />
W96 × H96 × D115 mm<br />
W110 × H110 × D125* mm<br />
(3.78” × 3.78” × 4.53”)<br />
(4.33” × 4.33” × 4.92”)<br />
Degree of protection IP 52 (Front panel) IP 52 (Front panel)<br />
Standards & Approvals CE / RoHS RoHS<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Power Transducers<br />
Product Selection Guide<br />
LT-UNIT Series<br />
54U /53U /52U /51U<br />
L-UNIT Series<br />
LSMT4<br />
K-UNIT Series<br />
CLS Series<br />
Power Transducers<br />
LT-UNIT L-UNIT K-UNIT<br />
n PT Transducer<br />
Average – LPNA KP, KPNA<br />
RMS LTPE LPE, LPNE KPE, KPNE<br />
2 channels, Average – L2PA, L2PNA –<br />
2 channels, RMS – L2PE, L2PNE –<br />
3 channels – L3PK –<br />
n CT Transducer<br />
Clamp-on Current Sensor;<br />
RMS sensing<br />
LTCEC – KCEC<br />
Average – LCNA KC, KCNA<br />
RMS LTCE, LTCNE LCE, LCNE KCE, KCNE<br />
2 channels, Average – L2CA, L2CNA –<br />
2 channels, RMS – L2CE, L2CNE –<br />
3 channels – L3CK –<br />
n PT/CT Transducer<br />
Average – LPCA –<br />
RMS – LPCE –<br />
n Watt / Var / Power Factor / Phase Angle / Frequency / Bidirectional Current Transducer<br />
Watt LTWT, LTWTN LWT, LWTN<br />
KEWT, KEWTN,<br />
KUWT, KUWTN,<br />
KUWE, KUWEN<br />
Var LTRP, LTRPN LRP, LRPN<br />
KERP, KERPN,<br />
KURE, KUREN<br />
Power Factor LTPF, LTPFN LPF, LPFN KEPF, KEPFN<br />
Power Factor<br />
(for unbalanced load)<br />
LTPFU, LTPFUN LPFU, LPFUN KEPFU, KEPFUN<br />
Phase Angle<br />
(self-powered)<br />
LTPA, LTPAN LPA, LPAN KEPA, KEPAN<br />
Phase Angle<br />
(for unbalanced load)<br />
LTPAU, LTPAUN LPAU, LPAUN KEPAU, KEPAUN<br />
Frequency LTHZ, LTHZN LHZ, LHZN KEHZ, KEHZN<br />
Bidirectional Current – LCY –<br />
Phase Angle<br />
(between two voltages)<br />
– LPD –<br />
n ZCT Transmitter<br />
ZCT<br />
(zero-phase current transformer)<br />
– – KCEZ<br />
n Limit Alarm<br />
Quad DC Alarm – L4AS –<br />
Configuration<br />
External Interface<br />
Single-phase / 2-wire and 3-wire,<br />
3-phase / 3-wire and 4-wire<br />
• Modbus, Do × 1, Di × 1<br />
• 4 – 20mA DC × 4<br />
• 1 – 5V DC × 4<br />
• 4 – 20mA DC × 2, Do × 1, Di × 1<br />
• 1 – 5V DC × 2, Do × 1, Di × 1<br />
• 4 – 20mA DC × 2, Do × 2<br />
• 1 – 5V DC × 2, Do × 2<br />
• Modbus, Do × 3<br />
• Do × 4<br />
Multi Power Transducer<br />
LSMT4<br />
Single-phase / 2-wire and 3-wire, 3-phase / 3-wire and 4-wire<br />
54U 54UC 54UL<br />
• Modbus, Do × 1, Di × 1<br />
• 4 – 20 mA DC × 4, Do × 1, Di × 11 – 5V DC × 4<br />
• 1 – 5 V DC × 4, Do × 1, Di × 1<br />
• Modbus, Do × 2<br />
• 4 – 20 mA DC × 4, Do × 2<br />
• 1 – 5 V DC × 4, Do × 2<br />
• 4 – 20 mA DC × 4 (isolated), Do × 1, Di × 1<br />
• 1 – 5 V DC × 4 (isolated), Do × 1, Di × 1<br />
• 4 – 20 mA DC × 4 (isolated), Do × 2<br />
• 1 – 5 V DC × 4 (isolated), Do × 2<br />
Multi Power Transducer<br />
L53U<br />
P.328<br />
Construction<br />
Terminal access at the front<br />
Connection;<br />
M4 screw terminals<br />
Voltage input<br />
(torque 1.4 N·m)<br />
Connector type terminal block<br />
Dielectric Strength 2000V AC 2500V AC<br />
Auxiliary Power<br />
AC / DC<br />
Operating Temperature<br />
-10 to +55°C<br />
(14 to 131°F)<br />
Mounting Surface or DIN rail DIN rail<br />
Dimensions<br />
Standars & Approvals<br />
Configuration<br />
Output<br />
W125 × H140 × D116 mm<br />
(4.92” × 5.51” × 4.57”)<br />
RoHS<br />
Single-phase / 2-wire and 3-wire,<br />
3-phase / 3-wire and 4-wire<br />
Current Voltage<br />
4 – 20mA DC 0 – 10V DC<br />
0 – 5V DC<br />
1 – 5V DC<br />
Energy count output<br />
W60 × H105 × D120 mm<br />
(2.36” × 4.13” × 4.72”)<br />
Single-phase / 2-wire and 3-wire,<br />
3-phase / 3-wire and 4-wire<br />
• Modbus, Do × 1, Di × 1<br />
• 4 – 20 mA DC × 4<br />
• 1 – 5 V DC × 4<br />
• CC-Link, Do × 1, Di × 1<br />
• CC-Link, Do × 2<br />
• LONWORKS, Do × 1, Di × 1<br />
• LONWORKS, Do × 2<br />
* 140 (5.51") for Configuration code 2<br />
Clamp-on Current Sensor<br />
CLS Series<br />
P.335<br />
Power Transducers<br />
Product Selection Guide<br />
Power Transducers<br />
LT-UNIT Series<br />
54U /53U /52U /51U<br />
L-UNIT Series<br />
LSMT4<br />
K-UNIT Series<br />
CLS Series<br />
Only typical models and specs are mentioned in this table. Please refer to the data sheet for the detailed specs.<br />
298<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
299
C<br />
300<br />
M4 Screw Connection<br />
LT-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
AC powered low-cost type. Conforming to IEC 60688.<br />
◆◆<br />
True RMS sensing<br />
◆◆<br />
Surface or DIN rail mounting<br />
◆◆<br />
M4 screw terminal<br />
◆◆<br />
Conform to IEC 60688<br />
◆◆<br />
Optional terminal cover<br />
◆◆<br />
Additional pulse rate output for totalizing<br />
counter (Watt Transducer)<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Power Transducers<br />
Product Selection Guide<br />
LT-UNIT Series<br />
54U /53U /52U /51U<br />
L-UNIT Series<br />
LSMT4<br />
K-UNIT Series<br />
CLS Series<br />
Power Transducers<br />
Construction<br />
Stand-alone; terminal access at the front<br />
Connection<br />
M4 screw terminals<br />
(chrome-plated steel; torque 1.2 N·m)<br />
Housing material Flame-resistant resin (black)<br />
Isolation<br />
Input to output to power<br />
Mounting<br />
Surface or DIN rail<br />
Dielectric strength<br />
2000V AC @1 minute<br />
(input to output to power to ground)<br />
Impulse withstand voltage<br />
1.2/50 μsec., ±5kV<br />
(input to output or ground)<br />
IEC Standard IEC 60688<br />
111 (4.37)<br />
2–M4 MTG HOLE<br />
111 (4.37)<br />
2–M4 MTG HOLE<br />
98 (3.86)<br />
80 (3.15)<br />
98 (3.86)<br />
80 (3.15)<br />
1 2 3<br />
5<br />
4<br />
6 7<br />
27 (1.06)<br />
39 (1.54)<br />
1 2 3 4 5 6<br />
7 8 9 10<br />
11 12 13 14 15 16<br />
10 (.39)<br />
3<br />
(.12)<br />
143 (5.63)<br />
DIN RAIL<br />
35mm wide<br />
8 (.31)<br />
[4 (.16)]<br />
• When mounting, no extra space is needed between units.<br />
10 (.39)<br />
7–M4 SCREW<br />
TERMINAL COVER (option /T)<br />
16–M4 SCREW<br />
TERMINAL COVER (option /T)<br />
54 (2.13)<br />
72 (2.83)<br />
3<br />
(.12)<br />
143 (5.63)<br />
8 (.31)<br />
[4 (.16)]<br />
• When mounting, no extra space is needed between units.<br />
DIN RAIL<br />
35mm wide<br />
n AC Voltage & Current Transducers<br />
Model Function Page<br />
LTPE AC Voltage Transducer P.301<br />
LTCE AC Current Transducer P.302<br />
LTCNE AC Current Transducer (self-powered, RMS sensing) P.303<br />
LTCEC<br />
AC Current Transducer<br />
(clamp-on current sensor; RMS sensing)<br />
P.304<br />
n Power Transducers<br />
Model Function Page<br />
LTWT Watt Transducer P.306<br />
LTWTN Watt Transducer (self-powered) P.308<br />
LTRP Var Transducer P.310<br />
LTRPN Var Transducer (self-powered) P.312<br />
LTPF Power Factor Transducer P.314<br />
LTPFN Power Factor Transducer (self-powered) P.316<br />
LTPFU Power Factor Transducer (for unbalanced load) P.318<br />
Model Function Page<br />
LTPFUN<br />
Power Factor Transducer<br />
(for unbalanced load; self-powered)<br />
P.320<br />
LTPA Phase Angle Transducer P.321<br />
LTPAN Phase Angle Transducer (self-powered) P.322<br />
LTPAU Phase Angle Transducer (for unbalanced load) P.323<br />
LTPAUN<br />
Phase Angle Transducer<br />
(for unbalanced load; self-powered)<br />
P.324<br />
LTHZ Frequency Transducer P.325<br />
LTHZN Frequency Transducer (self-powered) P.326<br />
300<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
C<br />
328<br />
Multi Power Monitor<br />
54U / 53U / 52U / 51U<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
n Multi Power Monitor 53U / Multi Power Transducer L53U<br />
◆◆<br />
Single-phase/2-wire and 3-wire, three-phase/3-wire, 4-wire systems<br />
◆◆<br />
Three line measured value/bargraph indicators plus energy count/info display (Model: 53U)<br />
◆◆<br />
IP 52 front panel (Model: 53U)<br />
◆◆<br />
Modbus, Ao, Do or Di options<br />
◆◆<br />
Model L53U without display is for DIN rail mounting<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Mounting<br />
Bracket(s)<br />
LCD with Backlight<br />
Measured Value +<br />
Bargraphs Displays<br />
■ FRONT VIEW<br />
■ REAR VIEW<br />
Voltage Input Terminals<br />
(removable)<br />
Current Input Terminals<br />
(non-removable)<br />
Configurator Jack<br />
Power Input Terminals<br />
Ext. Interface Terminals<br />
Voltage Input Terminals<br />
Current Input Terminals<br />
Information Display<br />
Network Interface<br />
Terminal block<br />
Configurator Jack<br />
Mode Selector<br />
Control Keys<br />
Power Input Terminals<br />
External Interface<br />
Terminals<br />
Model: 53U<br />
Model: L53U<br />
Power Transducers<br />
Product Selection Guide<br />
LT-UNIT Series<br />
54U /53U /52U /51U<br />
L-UNIT Series<br />
LSMT4<br />
K-UNIT Series<br />
Power Transducers<br />
SPECIFICATIONS (model: 53U) SPECIFICATIONS (model: L53U)<br />
GENERAL SPECIFICATIONS<br />
GENERAL SPECIFICATIONS<br />
Construction<br />
96-mm square (1/4 DIN size) panel flush mounted<br />
Voltage input Connector type terminal block<br />
Voltage input Connector type terminal block Connection<br />
Current input Screw terminal block<br />
Connection<br />
Current input Screw terminal block<br />
Output, power Connector type terminal block<br />
Output, Power Connector type terminal block<br />
Single phase/2-wire and 3-wire,<br />
Single phase/2-wire and 3-wire,<br />
Configuration<br />
3-phase/3-wire balanced/unbalanced load,<br />
Configuration<br />
3-phase/3-wire balanced/unbalanced load,<br />
3-phase/4-wire balanced/unbalanced load<br />
3-phase/4-wire balanced/unbalanced load<br />
Housing material Flame-resistant resin (gray)<br />
Housing material Flame-resistant resin (gray)<br />
Voltage input to current input to discrete input to<br />
Voltage input to current input to contact input Isolation<br />
discrete output to network interface or configurator<br />
Isolation<br />
to network interface or configurator jack<br />
jack or analog output to power<br />
or analog output to contact output* to power<br />
*Between each contact output except for External Interface code 8.<br />
Model Function Page<br />
CLS Series<br />
DEGREE OF PROTECTION<br />
Front panel<br />
IP52<br />
Terminal block, housing IP30<br />
DISPLAY<br />
Display<br />
LCD with LED backlight (LED OFF timer available)<br />
Signed 4 digits, 3 lines<br />
Display Energy 9 digits, 1 line<br />
Bargraph 3 points<br />
53U Multi Power Monitor (4 digital displays) P.330<br />
L53U Multi Power Transducer P.332<br />
n Accessories<br />
Model Function Page<br />
COP-US PC Configurator Cable (USB-miniature jack, isolated) ***<br />
MCN-CON PC Configurator Cable ***<br />
EXTERNAL DIMENSIONS<br />
n 53U<br />
n L53U<br />
mm (inch)<br />
60 (2.36)<br />
12 (.47) 108 (4.25) [3 (.12)]<br />
3 (.12) 96 (3.78)<br />
3 (.12)<br />
96 (3.78) 23 (.91) 80 (3.15) [12 (.47)]<br />
92 (3.62)<br />
2 (.08)<br />
GASKET MOUNTING BRACKET<br />
100 (3.94) dia.<br />
92 (3.62)<br />
105 (4.13)<br />
5 (.20)<br />
DIN RAIL<br />
35mm wide<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
328<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
2<br />
Multi Power Monitor 54U / 53U / 52U / 51U<br />
C<br />
329<br />
n Multi Power Monitor (4 digital displays) 54U<br />
◆◆<br />
110-mm-square panel flush mounted<br />
◆◆<br />
Two line measured value indicators, energy count/<br />
info display plus 60-segment bargraph<br />
◆◆<br />
IP 52 front panel<br />
◆◆<br />
Modbus, CC-Link, LONWORKS, Ao, Do or Di options<br />
◆◆<br />
Infrared interface to connect with PC Configurator<br />
Model Function Page<br />
54U Multi Power Monitor (4 digital displays) ***<br />
54UC Multi Power Monitor (4 digital displays, CC-Link) ***<br />
54UL Multi Power Monitor (4 digital displays, LONWORKS) ***<br />
n Accessories<br />
Model Function Page<br />
n Multi Power Monitor model: 52U<br />
◆◆<br />
Three digital meters<br />
◆◆<br />
IP66 robust front for tough<br />
industrial applications<br />
◆◆<br />
Conforms to IEC 688<br />
Model Function Page<br />
52U Multi Power Monitor ***<br />
52U-TM Modbus Extension Module (52U use) ***<br />
n Multi Power Meter model: 51U<br />
◆◆<br />
Three digital meters<br />
◆◆<br />
RS-485 or DC current output<br />
◆◆<br />
Easily replacing standard<br />
110 mm (4 5 / 16 in.) square<br />
size, long scale meter<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Power Transducers<br />
Product Selection Guide<br />
COP-IRU Infrared Communication Adaptor (PC-Configurator use) ***<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
CONFIGURATION CODE 1<br />
110 (4.33)<br />
25 (.98) 100 (3.94)<br />
91.5 (3.60)<br />
110 (4.33)<br />
91.5 (3.60)<br />
2<br />
Model Function Page<br />
51U Multi Power Meter ***<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
Power Transducers<br />
LT-UNIT Series<br />
54U /53U /52U /51U<br />
L-UNIT Series<br />
LSMT4<br />
K-UNIT Series<br />
CLS Series<br />
MOUNTING BRACKET<br />
2-M5 SCREW<br />
CONFIGURATION CODE 2<br />
110 (4.33)<br />
25 (.98)<br />
115 (4.53)<br />
91.5 (3.60)<br />
110 (4.33)<br />
91.5 (3.60)<br />
MOUNTING BRACKET<br />
2-M5 SCREW<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
329
C<br />
334<br />
Power Transducers<br />
L-UNIT / LS-UNIT/ K-UNIT Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
M3.5 Screw Connection<br />
L-UNIT Series<br />
Dual input/output modules (average or RMS)<br />
available for AC voltage/current types<br />
◆◆Self-powered and AC/DC line powered model<br />
available<br />
Multi Power Transducer<br />
model: LSMT4<br />
Measures AC current, voltage, active/reactive/<br />
apparent power and power factor<br />
◆◆10 DC voltage/mA outputs plus 2 Do<br />
◆◆Parameters are freely programmable with the front<br />
control buttons or by PC<br />
◆◆DIN rail mounted<br />
Power Transducers<br />
Product Selection Guide<br />
LT-UNIT Series<br />
54U /53U /52U /51U<br />
L-UNIT Series<br />
LSMT4<br />
K-UNIT Series<br />
CLS Series<br />
Power Transducers<br />
Plug-in<br />
K-UNIT Series<br />
Easy maintenance with plug-in base socket<br />
◆◆Minimum ripple<br />
◆◆Average or RMS sensing<br />
334<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Clamp-on Current Sensor<br />
CLS Series<br />
Clamp-on Current Sensor<br />
C335<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Screw Terminal<br />
◆◆Easy-to-install, clamp-on type current sensor<br />
◆◆Over-voltage clamp element for safety in open circuit<br />
◆◆Wide frequency band<br />
Indicators<br />
Limit Alarms<br />
Terminal Cover<br />
Primary Cable Here<br />
◆◆Screw terminal connection<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
n model: CLSA<br />
Model CLSA-08 CLSA-12 CLSA-30 CLSA-50<br />
Applicable max.<br />
wire diameter<br />
10 mm 16 mm 24 mm 36 mm<br />
Primary rating 80A 120A 300A 500A<br />
Related products<br />
Special cable (3m)<br />
(model: CLSA-08C-30)<br />
–<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
n model: CLSB<br />
Model CLSB-R5 CLSB-05 CLSB-10 CLSB-20 CLSB-40 CLSB-60<br />
Applicable max.<br />
wire diameter<br />
10 mm 10 mm 16 mm 24 mm 35 mm 35 mm<br />
Primary rating 5A 50A 100A 200A 400A 600A<br />
n model: CLSC<br />
Model CLSC-10 CLSC-25 CLSC-50 CLSC-60<br />
Applicable max.<br />
wire diameter<br />
24 mm 24 mm 36 mm 36 mm<br />
Primary rating 100A 250A 500A 600A<br />
Secondary rating 1A 1A 1A 1A<br />
n model: CLSD<br />
Model CLSD-A CLSD-B CLSD-C CLSD-D<br />
Applicable max.<br />
wire diameter<br />
24 mm 36 mm 60 mm 100 mm<br />
Primary rating 150A, 200A 300A, 400A 800A, 1000A 2000A<br />
Secondary rating 1A 1A 1A 1A<br />
Power Transducers<br />
Product Selection Guide<br />
Power Transducers<br />
LT-UNIT Series<br />
54U /53U /52U /51U<br />
L-UNIT Series<br />
LSMT4<br />
K-UNIT Series<br />
CLS Series<br />
n model: CLSE<br />
Model CLSE-R5 CLSE-05 CLSE-10 CLSE-20 CLSE-40 CLSE-60<br />
Applicable max.<br />
wire diameter<br />
10 mm 10 mm 16 mm 24 mm 36 mm 36 mm<br />
Primary rating 5A 50A 100A 200A 400A 600A<br />
Secondary rating 1.65mA 20mA 20mA 20mA 20mA 20mA<br />
Related products<br />
• Special cable (model: CLS-CN) Used in combination with the CLSA-08C.<br />
• Special cable (model: CLSA-08C)<br />
Clamp-on Pulse Pickup model: CLSP<br />
◆◆Indirectly detects pulse signals counted at a watt-hour meter<br />
◆◆Provides the watt-hour meter pulse signals to a PLC or a demand<br />
monitor equipment<br />
◆◆No polarity input<br />
◆◆Open collector output<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
335
Indicators<br />
Bright, Clear, and Colorful Displays<br />
Voltage (DC, AC), current (DC, AC), temperature, potentiometer, process,<br />
strain gauge and pulse train inputs.<br />
Wide range of Digital or Bargraph models, sizes, and capabilities to display,<br />
alarm output, communications and analog output.<br />
ISP ’12<br />
337
D<br />
Signal Conditioners<br />
338 Indicators Product Selection Guide<br />
Indicators Product Selection Guide<br />
D339<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Bargraph Indicator<br />
48NV<br />
Bargraph Indicating Alarm<br />
48NAVx<br />
Bargraph Indicating Alarm<br />
with 4-digit digital meter<br />
48NDVx<br />
Bargraph Indicating Alarm<br />
(Sensor Input)<br />
48NAx<br />
Bargraph Indicating Alarm<br />
with 4-digit digital meter (Sensor Input)<br />
48NDx<br />
Bargraph Indicator<br />
48SV<br />
Bargraph Indicating Alarm<br />
49AV2<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Indicators<br />
Limit Alarms<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
P.342 P.342 P.342 P.342 P.342 P.342 P.343<br />
Bargraph 101-segment LED 101-segment LED 101-segment LED 101-segment LED 101-segment LED 51-segment LED 51-segment LED<br />
Scale Length<br />
100 mm (3.96”) long, 100 mm (3.96”) long, 100 mm (3.96”) long, 100 mm (3.96”) long,<br />
100 mm (3.96”) long,<br />
89 mm (3.50”) long,<br />
50 mm (1.97”) long<br />
3.00 mm (.12”) wide 3.00 mm (.12”) wide 3.00 mm (.12”) wide 3.00 mm (.12”) wide<br />
3.00 mm (.12”) wide<br />
angle 120°<br />
Scale Custom Custom Custom Custom Custom 0 – 100% 0 – 100%<br />
Bar Color<br />
Red, Amber, Green, Blue<br />
Red, Amber, Green, Blue, Red, Amber, Green, Blue, Red, Amber, Green, Blue,<br />
Red, Amber, Green, Blue,<br />
Multi-color<br />
Red<br />
Multi-color<br />
Multi-color<br />
Multi-color<br />
Multi-color<br />
(Red, Orange and Green)<br />
Digital Meter – – 4 digits, Red LED – 4 digits, Red LED – 4 digits, Red LED<br />
Connection M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal<br />
Connector<br />
(leadwires soldered)<br />
M4 screw terminal<br />
Direct Sensor Input – – – Yes Yes – –<br />
Alarm Output – 2 or 4 points 2 or 4 points 2 or 4 points 2 or 4 points – 2 or 4 points<br />
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC DC AC / DC<br />
Mounting Direction Vertical / Horizontal Vertical / Horizontal Vertical Vertical / Horizontal Vertical Vertical / Horizontal Vertical<br />
Dimensions<br />
W36 × H144 × D103 mm W36 × H144 × D103 mm W36 × H144 × D103 mm W36 × H144 × D103 mm<br />
W36 × H144 × D103 mm W18 × H72 × D118 mm W96 × H96 × D116 mm<br />
(1.42” × 5.67” × 4.06”) (1.42” × 5.67” × 4.06”) (1.42” × 5.67” × 4.06”) (1.42” × 5.67” × 4.06”)<br />
(1.42” × 5.67” × 4.06”) (0.71” × 2.83” × 4.65”) (3.78” × 3.78” × 4.61”)<br />
Degree of Protection IP65 front cover IP65 front cover IP65 front cover IP65 front cover IP65 front cover – –<br />
Standards & Approvals CE / RoHS CE / RoHS CE / RoHS CE / RoHS CE / RoHS – –<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
Digital Panel Meters<br />
48NV 48NAVx 48NDVx 48NAx 48NDx 48SV 49AV2<br />
n Bargraph Indicator<br />
DC Input 48NV – – – – 48SV –<br />
n Bargraph Indicating Alarm<br />
DC Input – 48NAV – – – – –<br />
Transmitter Output – 48NAVA – – – – –<br />
2-wire Transmitter Excitation – 48NAVD – – – – –<br />
Thermocouple Input – – – 48NAT – – –<br />
RTD Input – – – 48NAR – – –<br />
Potentiometer Input – – – 48NAM – – –<br />
n Bargraph Indicating Alarm (with 4-digit digital meter)<br />
DC Input – – 48NDV – – – 49AV2<br />
Transmitter Output – – 48NDVA – – – –<br />
2-wire Transmitter Excitation – – 48NDVD – – – –<br />
Thermocouple Input – – – – 48NDT – –<br />
RTD Input – – – – 48NDR – –<br />
Potentiometer Input – – – – 48NDM – –<br />
Bargraph Indicators<br />
Digital Panel Meters<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
338<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
339
D<br />
Signal Conditioners<br />
340 Indicators Product Selection Guide<br />
Indicators Product Selection Guide<br />
D341<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
LCD Display<br />
47D Series<br />
LED Display<br />
47L Series<br />
LED Display<br />
40 Series<br />
LED Display<br />
46 Series<br />
Small Size<br />
43DV2/43DV1<br />
Loop Powered<br />
6DV/6DVI<br />
Loop Powered<br />
6DV-B/6DVI-B<br />
Loop Powered<br />
43AL Series<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Power Transducers<br />
Indicators<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
Display<br />
Connection<br />
5 1/2 digits<br />
Red / Green LCD<br />
M3 screw terminal /<br />
Euro Type Connector Terminal<br />
/ 50-pin connector<br />
43DV2 43DV1 43AL1 43AL<br />
P.372 P.373 P.408 P.408 P.418 P.412 P.412 43AL-B P.418<br />
4, 4 1/2 or 6 digits<br />
Red, Orange, Green,<br />
Bluegreen, Blue, White LED<br />
(47LYV: Red/Orange only)<br />
3 1/2 digits (40LV) ,<br />
4 digits (40DV, 40DR)<br />
Red LED<br />
4 digits<br />
Red / Green LED<br />
M3 screw terminal M3 screw terminal M3 screw terminal<br />
4 digits<br />
Red LED<br />
Screwless spring<br />
terminal or<br />
Separable<br />
screwless<br />
spring terminal<br />
3 1/2 digits<br />
Red LED<br />
Connector<br />
(leadwires<br />
soldered)<br />
4 digits<br />
Red LED<br />
Euro terminal<br />
4 digits<br />
Red LED<br />
Euro terminal block or<br />
M3 screw terminal<br />
4 digits<br />
Red LED<br />
Screwless spring<br />
terminal or<br />
Separable<br />
screwless spring<br />
terminal<br />
Scaling Yes Yes Yes (40DV only) – Yes Yes Yes Yes<br />
Direct Sensor Input Yes Yes Yes – – – – –<br />
Alarm Output Optional, 2 or 4 points Optional, 2 or 4 points – Optional, 2 or 4 points – – – –<br />
BCD Output Optional – – Optional – – – –<br />
Network Interface<br />
Optional, RS-485 / Modbus<br />
RTU<br />
– – Optional – – – –<br />
Analog Output Optional Optional for selected models – Optional – – – –<br />
Power Input AC / DC AC / DC AC (40DV) / DC AC / DC DC None None None<br />
Dimensions<br />
W96 × H48 × D98.5 mm<br />
(3.78” × 1.89” × 3.88”)<br />
W96 × H48 × D98.5 mm<br />
(3.78” × 1.89” × 3.88”)<br />
W96 × H48 × D96 mm<br />
(3.78” × 1.89” × 3.78”)<br />
W102.5 × H48 × D104 mm<br />
(4.04” × 1.89” × 4.09”)<br />
W48 × H24 ×<br />
D42*, 58 mm<br />
(1.89” × 0.94” ×<br />
1.65”, 2.28”)<br />
W48 × H24 ×<br />
D72 mm<br />
(1.89” × 0.94” ×<br />
2.83”)<br />
70 (2.76”) dia. 110 (4.33”) dia.<br />
W48 × H24 ×<br />
D42*, 58 mm<br />
(1.89” × 0.94” ×<br />
1.65”, 2.28”)<br />
Terminal block<br />
W48 × H24 ×<br />
D40 mm<br />
(1.89” × 0.94” ×<br />
1.57”)<br />
Degree of Protection IP66 front panel IP66 front panel – – – – IP66 / IP67 – IP66 / IP67<br />
Standards & Approvals RoHS CE for selected models / RoHS CE / RoHS – CE / RoHS – CE / ATEX / FM / RoHS CE / ATEX / FM / RoHS CE / RoHS CE / UL / RoHS CE / ATEX / FM<br />
3 1/2 digits<br />
Red LED<br />
Euro terminal<br />
110 (4.33”) dia.<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
Digital Panel Meters<br />
DC Input<br />
(indicator only)<br />
DC Input<br />
(indicator only /<br />
intrinsically safe)<br />
DC Input<br />
(indicator only /<br />
explosion-proof)<br />
47D Series 47L Series 40 Series 46 Series 43DV Series 6DV Series 6DV-B Series 43AL Series<br />
– 47LYV 40LV, 40DV 46DL2 43DV2, 43DV1 – – 43AL1, 43AL<br />
– – – – – 6DV, 6DVI – –<br />
– – – – – – 6DV-B, 6DVI-B 43AL-B<br />
DC Input 47DV 47LV – 46DV2 – – – –<br />
Thermocouple Input 47DT 47LT – – – – – –<br />
RTD Input 47DR 47LR 40DR – – – – –<br />
Potentiometer Input 47DM 47LM – – – – – –<br />
AC Input 47DAC 47LAC – – – – – –<br />
Strain Gauge Input – 47LLC – – – – – –<br />
VT Input – 47LPT – – – – – –<br />
CT Input – 47LCT – – – – – –<br />
Frequency Input – 47LPA, 47LHZ, 47LPQ – – – – – –<br />
Digital Panel Meters<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
* 42mm (1.65”) for one block terminal<br />
340<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
341
342D<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Bargraph Indicators<br />
n 48N Series<br />
48N is a 9/64 DIN size (36 × 144 mm), tricolor or monocolor 101-segment bargraph<br />
indicator.<br />
◆◆<br />
3-mm wide, bright color bars<br />
◆◆<br />
IP65 front cover<br />
◆◆<br />
Blue LED<br />
◆◆<br />
Two-wire transmitter excitation supply (option)<br />
◆◆<br />
Transmitter output (option)<br />
◆◆<br />
Direct sensor input<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
48NV 48NAx 48NDx<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
Digital Panel Meters<br />
48NV 48NAx, 48NAVx 48NDx, 48NDVx 48NV, 48NAx, 48NAVx, 48NDx, 48NDVx<br />
144 (5.67) 4 * 1<br />
100 (3.94)<br />
(.16)<br />
144 (5.67) 4 * 1<br />
100 (3.94)<br />
(.16)<br />
4 * 1<br />
(.16)<br />
144 (5.67)<br />
100 (3.94)<br />
2–M3 SCREWS<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
16–M3 SCREW<br />
TERMINALS<br />
137.5 (5.41)<br />
36 (1.42)<br />
36 (1.42)<br />
*1. Space required when replacing the scale plate.<br />
36 (1.42) 10 (.39) 75 (2.95)<br />
18<br />
31 (1.22)<br />
103 (4.06)<br />
(.71)<br />
n 48SV<br />
Displaying a process variable in graphic bargraph of 51 LED segments<br />
◆◆<br />
Clear LED<br />
◆◆<br />
High-density mounting<br />
◆◆<br />
Small size: W18×H72×D118 mm (0.71”×2.83”×4.65”)<br />
Model Function Page<br />
48SV Bargraph Indicator ***<br />
48SV<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
342<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Bargraph Indicators<br />
D343<br />
Signal Conditioners<br />
SPECIFICATIONS<br />
Construction<br />
Degree of protection<br />
Connection<br />
Material<br />
Power input<br />
Panel flush mounting<br />
IP65;<br />
applicable to the front panel for single 48N module<br />
mounted according to the specified panel cutout<br />
M3 screw terminals<br />
(nickel plated steel; torque 0.6 N·m)<br />
Housing : Flame resistant resin (black)<br />
Scale plate: Flame resistant resin<br />
(white scale & characters on black<br />
base)<br />
AC: Operational voltage range 85 – 264V<br />
DC: Operational voltage range 24V ±15%<br />
■■Bargraph Indicator<br />
Model Function Page<br />
48NV Bargraph Indicator P.347<br />
■■Bargraph Indicating Alarm<br />
Model Function Page<br />
48NAV Bargraph Indicating Alarm P.348<br />
48NAVA<br />
Bargraph Indicating Alarm<br />
(with isolated DC output)<br />
P.350<br />
48NAVD<br />
Bargraph Indicating Alarm<br />
(with 2-wire transmitter excitation)<br />
P.352<br />
48NAT Bargraph Indicating Alarm (thermocouple input) P.354<br />
48NAR Bargraph Indicating Alarm (RTD input) P.356<br />
48NAM Bargraph Indicating Alarm (potentiometer input) P.358<br />
Bargraph Indicator<br />
Single or Dual<br />
Bargraph<br />
101-segment LED, 100 mm (3.96”) long,<br />
3.00 mm (.12”) wide<br />
Mounting direction Vertical, Horizontal<br />
Bar LED color<br />
Red, Amber, Green, Blue<br />
Bargraph Indicating Alarm<br />
101-segment LED, 100 mm (3.96”) long,<br />
Bargraph<br />
3.00 mm (.12”) wide<br />
Red, Amber, Green, Blue,<br />
Bar LED color<br />
Multi-color (red, orange and green)<br />
Mounting direction Vertical, Horizontal<br />
Relay contact (2 points or 4 points)<br />
Alarm output<br />
Rated load: 250V AC @1A (cosø=1)<br />
30V DC @5A (resistive load)<br />
Bargraph Indicating Alarm (with 4-digit digital meter)<br />
101-segment LED, 100 mm (3.96”) long,<br />
Bargraph<br />
3.00 mm (.12”) wide<br />
Red, Amber, Green, Blue,<br />
Bar LED color<br />
Multi-color (red, orange and green)<br />
Mounting direction Vertical<br />
Digital indicator<br />
4 digits (-1999 to 0 to 9999), red LED<br />
Relay contact (2 points or 4 points)<br />
Alarm output<br />
Rated load: 250V AC @1A (cosø=1)<br />
30V DC @5A (resistive load)<br />
■■<br />
Bargraph Indicating Alarm (with 4-digit digital meter)<br />
Model Function Page<br />
48NDV<br />
48NDVA<br />
48NDVD<br />
48NDT<br />
48NDR<br />
48NDM<br />
Bargraph Indicating Alarm<br />
(with 4-digit digital meter)<br />
Bargraph Indicating Alarm<br />
(with 4-digit digital meter; with isolated DC output)<br />
Bargraph Indicating Alarm<br />
(with 4-digit digital meter; with 2-wire transmitter<br />
excitation)<br />
Bargraph Indicating Alarm<br />
(with 4-digit digital meter; thermocouple input)<br />
Bargraph Indicating Alarm<br />
(with 4-digit digital meter; RTD input)<br />
Bargraph Indicating Alarm<br />
(with 4-digit digital meter; potentiometer input)<br />
P.360<br />
P.362<br />
P.364<br />
P.366<br />
P.368<br />
P.370<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
Digital Panel Meters<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
n 49AV2<br />
Displaying a process variable in graphic bargraph of 51 LED segments<br />
◆◆<br />
Clear 4-digit digital meter<br />
◆◆<br />
Providing max. 4 alarm contact outputs<br />
◆◆<br />
Multi-color indicator<br />
Model Function Page<br />
49AV2<br />
Bargraph Indicating Alarm<br />
(with 4-digit digital meter) ***<br />
ISP ’12<br />
49AV2<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
Specifications are subject to change without notice.<br />
343
D<br />
372<br />
Digital Panel Meters<br />
47 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
n 47D Series (LCD display)<br />
Red or Green LCD selectable (negative type LCD with LED backlight).<br />
1/8 DIN size.<br />
◆◆<br />
Field-selectable input range<br />
◆◆<br />
IP66 front panel<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
Digital Panel Meters<br />
SPECIFICATIONS<br />
Construction<br />
Degree of protection<br />
Connection<br />
Housing material<br />
Display<br />
Panel flush mounting<br />
IP66;<br />
applicable to the front of the panel meter<br />
mounted according to the specified panel cutout<br />
Relay output, network interface:<br />
M3 screw terminals<br />
(nickel plated steel; torque 0.6 N·m)<br />
Photo MOS relay, event trigger input:<br />
Terminal block<br />
(applicable wire size: max. 1.3 dia., 0.5 – 1.25 mm 2 )<br />
BCD output:<br />
50-pin connector<br />
(Honda Tsushin Kogyo HDR-EC50LFDT1-SLE+)<br />
Flame resistant resin (gray)<br />
LCD with LED backlight, 14.2 mm (.56) high,<br />
5 1/2 digits (-20000 to 100000), red or green<br />
changeable at alarm<br />
Main display<br />
Scaling range : -20000 to 100000<br />
Decimal point position: 10 –1 , 10 –2 , 10 –3 , 10 –4<br />
or none<br />
LCD with LED backlight,<br />
Sub display<br />
5.5 mm (.22) high, 7 digits<br />
Excitation Supply<br />
+12V sensor excitation Current rating: 84mA DC maximum<br />
+24V two-wire transmitter<br />
Current rating: 22mA DC maximum<br />
excitation<br />
Power Input<br />
Operational voltage range 85 – 264V<br />
AC<br />
50/60 Hz, 12VA max.<br />
Operational voltage range 24V ±10% or<br />
DC<br />
85 – 150V<br />
Output<br />
0 – 5V DC, ±5V DC, ±10V DC,<br />
DC output<br />
0 – 20mA DC, 4 – 20mA DC<br />
• Alarm output: N.O. relay, 4 points<br />
• Alarm output: SPDT relay, 2 points<br />
• Alarm output: N.O. photo MOS relay, 4 points<br />
• Network interface: RS-485 / Modbus RTU<br />
• BCD output<br />
• Event trigger input<br />
Options<br />
• Alarm output: N.O. relay, 4 points +<br />
Network interface: RS-485 / Modbus RTU<br />
• Alarm output: SPDT relay, 2 points +<br />
Network interface: RS-485 / Modbus RTU<br />
• Alarm output: N.O. photo MOS relay, 4 points +<br />
BCD output<br />
• Event trigger input + BCD output<br />
EXTERNAL DIMENSIONS<br />
48 (1.89)<br />
103 (4.06)<br />
96 (3.78)<br />
12.5 (.49)<br />
2 (.08)<br />
98.5 (3.88)<br />
86 (3.39)<br />
mm (inch)<br />
Model Function Page<br />
47DV<br />
DC Input Digital Panel Meter<br />
(5 1/2 digit, LCD display type)<br />
P.374<br />
47DT<br />
47DR<br />
47DM<br />
47DAC<br />
Thermocouple Input Digital Panel Meter<br />
(5 1/2 digit, LCD display type)<br />
RTD Input Digital Panel Meter<br />
(5 1/2 digit, LCD display type)<br />
Potentiometer Input Digital Panel Meter<br />
(5 1/2 digit, LCD display type)<br />
AC Input Digital Panel Meter<br />
(5 1/2 digit, LCD display type)<br />
47 (1.85)<br />
P.376<br />
P.378<br />
P.380<br />
P.382<br />
■■Accessories<br />
Model Function Page<br />
HDR40 Special Cable ***<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
372<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Digital Panel Meters 47 Series<br />
D<br />
373<br />
Signal Conditioners<br />
n 47L Series (LED display)<br />
LED color selectable, Red, Orange, Green, Bluegreen, Blue, White.<br />
1/8 DIN size.<br />
◆◆<br />
Field-selectable input range<br />
◆◆<br />
IP66 front panel<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
SPECIFICATIONS<br />
Construction<br />
Panel flush mounting<br />
IP66;<br />
Degree of protection applicable to the front of the panel meter<br />
mounted according to the specified panel cutout<br />
Connection<br />
M3 screw terminals<br />
(nickel plated steel; torque 0.6 N·m)<br />
Housing material Flame resistant resin (gray)<br />
Display (47LYV, 47LV, 47LAC, 47LLC, 47LPT, 47LCT, 47LPA, 47LHZ)<br />
Display<br />
16 mm (.63) high, 4 1/2 digits (±19999), LED<br />
Decimal point position<br />
10 –1 , 10 –2 , 10 –3 , 10 –4 or none<br />
Display (47LT, 47LR, 47LM)<br />
Display<br />
16 mm (.63) high, 4 digits (±9999), LED<br />
Decimal point position<br />
Display (47LPQ)<br />
Display<br />
Decimal point position<br />
Power Input<br />
AC<br />
DC<br />
Output<br />
DC output<br />
Alarm output<br />
10 –1 , 10 –2 , 10 –3 , 10 –4 or none<br />
16 mm (.63) high, 6 digits, LED<br />
10 –1 , 10 –2 , 10 –3 , 10 –4 , 10 –5 or none<br />
Operational voltage range 85 – 264V<br />
50/60 Hz, approx. 6.5VA<br />
Operational voltage range for 24V ±10% or<br />
85 – 150V<br />
Current: 4 – 20mA DC, 0 – 20mA DC<br />
Voltage: 0 – 10V DC, 0 – 5V DC, 1 – 5V DC,<br />
-10 – +10V DC<br />
N.O. relay contact, 4 points<br />
SPDT relay contact, 2 points<br />
EXTERNAL DIMENSIONS<br />
48 (1.89)<br />
103 (4.06)<br />
96 (3.78)<br />
12.5 (.49)<br />
2 (.08)<br />
98.5 (3.88)<br />
86 (3.39)<br />
mm (inch)<br />
Model Function Page<br />
47LYV<br />
DC Input Digital Panel Meter<br />
(4 1/2 digit, LED display type)<br />
P.384<br />
47LV<br />
47LT<br />
47LR<br />
47LM<br />
47LAC<br />
47LLC<br />
47LPT<br />
47LCT<br />
47LPA<br />
47LHZ<br />
47LPQ<br />
DC Input Digital Panel Meter<br />
(4 1/2 digit, LED display type)<br />
Thermocouple Input Digital Panel Meter<br />
(4-digit, LED display type)<br />
RTD Input Digital Panel Meter<br />
(4-digit, LED display type)<br />
Potentiometer Input Digital Panel Meter<br />
(4-digit, LED display type)<br />
AC Input Digital Panel Meter<br />
(4 1/2 digit, LED display type, true RMS sensing)<br />
Strain Gauge Input Digital Panel Meter<br />
(4 1/2 digit, LED display type)<br />
VT Input Digital Panel Meter<br />
(4 1/2 digit, LED display type, true RMS sensing)<br />
CT Input Digital Panel Meter<br />
(4 1/2 digit, LED display type, true RMS sensing)<br />
Frequency Input Digital Panel Meter<br />
(4 1/2 digit, LED display type)<br />
Frequency Input Digital Panel Meter<br />
(4 1/2 digit, LED display type)<br />
Pulse Input Totalizer<br />
(6-digit, LED display type)<br />
47 (1.85)<br />
P.386<br />
P.388<br />
P.390<br />
P.392<br />
P.394<br />
P.396<br />
P.398<br />
P.400<br />
P.402<br />
P.404<br />
P.406<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
Digital Panel Meters<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
373
D<br />
408<br />
Digital Panel Meters<br />
40 / 46 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
n 40 Series<br />
Large 0.8” (20.3 mm) high red LED.<br />
1/8 DIN size.<br />
◆◆<br />
DC volt/ammeter or Process meter<br />
◆◆<br />
Hold function<br />
◆◆<br />
Low cost<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
40LV<br />
40DV, 40DR<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
EXTERNAL DIMENSIONS<br />
mm (inch)<br />
Construction<br />
Connection<br />
Housing material<br />
Panel flush mounting<br />
M3 screw terminals (torque 0.6 N·m)<br />
Flame-resistant resin (gray)<br />
103 (4.06)<br />
96 (3.78)<br />
11<br />
(.43)<br />
96 (3.78)<br />
85 (3.35)<br />
Indicators<br />
Product Selection Guide<br />
Display (40LV)<br />
Display<br />
3 1/2 digits of 20.3 mm height, red LED<br />
Display range -1999 to 1999<br />
Decimal point position<br />
3 positions selectable by short circuit between<br />
terminals 5, 6 or 7 to 3<br />
48 (1.89)<br />
45 (1.77)<br />
Display (40DV, 40DR)<br />
Display<br />
4 digits of 20.3 mm height, red LED<br />
Bargraph Indicators<br />
Display range -9999 to 9999<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
Digital Panel Meters<br />
Decimal point position<br />
Power Input<br />
AC (40DV only)<br />
DC<br />
10 –1 , 10 –2 , 10 –3 or none<br />
• Operational voltage range 85 – 132V AC,<br />
47 – 66 Hz, Approx. 1.6 VA<br />
• Operational voltage range 170 – 264V AC,<br />
47 – 66 Hz, Approx. 1.0 VA<br />
Operational voltage range 24 V ±20 %,<br />
ripple 10 %p-p max., Approx. 0.5 W<br />
Model Function Page<br />
40LV<br />
DC Input Digital Panel Meter<br />
(3 1/2 digit, without scaling)<br />
P.409<br />
40DV<br />
40DR<br />
DC Input Digital Panel Meter<br />
(4 digits, process meter)<br />
RTD Input Digital Panel Meter<br />
(4 digits, process meter)<br />
P.410<br />
P.411<br />
n 46 Series<br />
Red or Green LED selectable. 1/8 DIN size.<br />
◆◆<br />
Large main display plus two sub displays indicating peak/valley values or alarm setpoints (46DV2)<br />
◆◆<br />
Field-selectable input range<br />
◆◆<br />
Optional outputs: alarm, transmitter output, BCD, RS-232C, RS-485<br />
available for the 46DV2<br />
Model Function Page<br />
46DV2<br />
DC Input Digital Panel Meter<br />
(4-digit, alarm and various output options) ***<br />
46DL2 DC Input Digital Panel Meter (4-digit) ***<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
408<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
D<br />
412<br />
Loop Powered Indicator<br />
6DV Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
4–20mA input powered.<br />
No external power source required.<br />
◆◆<br />
Scaling & linearization selectable via the front<br />
control buttons<br />
◆◆<br />
NEMA 4X, IP66/IP67 (6DV-B / 6DVI-B)<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
Digital Panel Meters<br />
SPECIFICATIONS<br />
6DV<br />
Connection<br />
Euro terminal block<br />
Applicable wire size AWG26 – 16 (0.14 – 1.5 mm 2 )<br />
Housing material Flame-resistant resin (black)<br />
Proportional, SQRT (X 1/2 ), RT32 (X 3/2 ), RT52 (X 5/2 ),<br />
Linearization<br />
user’s linearization table (max. 21 calibration<br />
points)<br />
LED<br />
8 mm (.3”) 7-segment, red<br />
Number of display digits 4<br />
Scaling range -1999 to 9999<br />
Engineering unit display Unit label included; LED backlight provided<br />
DC current : 4 – 20mA DC<br />
Input<br />
Voltage drop : Approx. 3.7V with 4mA<br />
Approx. 4.0V with 20mA<br />
EXTERNAL DIMENSIONS<br />
6DV / 6DVI<br />
70 (2.76) dia. 21 (.83)<br />
33 (1.30) 15.5 (.61)<br />
6DV-B / 6DVI-B<br />
approx. 7 (.28)<br />
6DV / 6DVI<br />
114 (4.49) max. 78 (3.07)<br />
110 (4.33)<br />
6DV-B / 6DVI-B<br />
Model Function Page<br />
6DV-B<br />
4-digit Loop Powered Indicator (outdoor enclosure,<br />
intrinsically safe/explosion-proof)<br />
P.413<br />
6DVI-B<br />
4-digit Loop Powered Indicator (outdoor enclosure,<br />
intrinsically safe)<br />
P.414<br />
6DV 4-digit Loop Powered Indicator (intrinsically safe) P.416<br />
6DVI 4-digit Loop Powered Indicator (intrinsically safe) P.417<br />
■■Accessories<br />
Model Function Page<br />
6BX-E Outdoor Enclosure ***<br />
A-34 DIN Rail Mounting Adaptor ***<br />
A-35 6BX-E Mounting Adaptor ***<br />
A-6 Mounting Spacer ***<br />
mm (inch)<br />
2–G1/2, 1/2NPT,<br />
M20x1.5 or PG13.5<br />
2–5 (.20) dia.<br />
174 (6.85)<br />
39 (1.54)<br />
dia.<br />
110 (4.33) dia.<br />
19 (.75)<br />
*Two cable glands and one plug are provided with TIIS flameproof type.<br />
Use them according to the field wiring requirements.<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
412<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
D<br />
418<br />
Digital Panel Meters<br />
43 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Large 0.8” (20.3 mm) high red LED. 1/32 DIN size.<br />
◆◆<br />
1/32 DIN size<br />
◆◆<br />
Easy-to-wire tension clamp connection<br />
Loop Powered<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
◆◆<br />
Process scaling<br />
◆◆<br />
No external power supply needed for<br />
the 43AL1 and 43AL-B<br />
◆◆<br />
NEMA 4X, IP66/IP67 (43AL-B)<br />
Loop Powered<br />
43AL1 43DV2 43AL-B<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Indicators<br />
Product Selection Guide<br />
Bargraph Indicators<br />
SPECIFICATIONS<br />
43AL1, 43DV2<br />
Construction<br />
Connection<br />
Housing material<br />
LED<br />
Number of display digits 4<br />
Scaling range -1999 to 9999<br />
Panel flush mounting<br />
Screwless spring terminal or<br />
Separable screwless spring terminal<br />
Flame-resistant resin (gray)<br />
10.2 mm height, red<br />
Model Function Page<br />
43AL-B<br />
3 1/2 Digit 2-wire DC Meter<br />
(explosion-proof; outdoor enclosure)<br />
P.419<br />
43AL1 Loop Powered Digital Panel Meter (process meter) P.420<br />
43AL 3 1/2 Digit 2-wire DC Panel Meter P.421<br />
43DV2 DC Input Digital Panel Meter (process meter) P.422<br />
43DV1-S 3 1/2 Digit DC Panel Meter (Process Meter) ***<br />
43DV1-V 3 1/2 Digit DC Panel Meter (DC Voltmeter) ***<br />
■■Accessories<br />
Model Function Page<br />
6BX-E Outdoor Enclosure ***<br />
A-35 6BX-E Mounting Adaptor ***<br />
47 Series<br />
40 Series<br />
46 Series<br />
6DV Series<br />
43 Series<br />
Digital Panel Meters<br />
EXTERNAL DIMENSIONS<br />
43AL1 / 43DV2<br />
24 (.94)<br />
50.5 (1.99)<br />
48 (1.89)<br />
5.5<br />
(.22)<br />
35 (1.38)<br />
17.5 (.69) for Separable terminal<br />
1.5 (.06) for One block terminal<br />
mm (inch)<br />
43AL-B<br />
approx. 7 (.28)<br />
114 (4.49) max. 78 (3.07)<br />
110 (4.33)<br />
2–G1/2, 1/2NPT,<br />
M20x1.5 or PG13.5<br />
174 (6.85)<br />
39 (1.54)<br />
dia.<br />
110 (4.33) dia.<br />
19 (.75)<br />
22 (.87)<br />
*Two cable glands and one plug are provided with TIIS flameproof type.<br />
Use them according to the field wiring requirements.<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
418<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Limit Alarms<br />
Monitoring a process signal and<br />
providing limit alarm trips<br />
Wide range of limit alarming products to choose from, including features<br />
such as potentiometer, rotary dial and pushbutton set points,<br />
DC output, LED or LCD display.<br />
ISP ’12<br />
423
E<br />
424 Limit Alarms Product Selection Guide<br />
Limit Alarms Product Selection Guide<br />
E<br />
425<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
n Digital Adjustments n Digital Adjustments n Rotary Switch / Potentiometer / Various Setpoint Adjustments<br />
Digital Adjustments<br />
AS4 Series<br />
LCD Display<br />
M7E-UNIT Series<br />
Ultra-Slim<br />
M6 Series<br />
MSEF<br />
Rotary Switch Adj.<br />
AL-UNIT Series<br />
Potentiometer Adj.<br />
A-UNIT Series<br />
Three-turn screwdrivers, Remote dial<br />
potentiometer or DC input<br />
M-PAC Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Limit Alarms<br />
Product Selection Guide<br />
Construction Plug-in Plug-in Ultra-slim Plug-in Plug-in Plug-in Plug-in<br />
Connection M3.5 screw terminal M3 screw terminal<br />
Tension-clamp (M6S),<br />
M3 screw terminal (M6N),<br />
M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal<br />
Euro terminal (M6D)<br />
Isolation Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power<br />
Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC<br />
Input Range Selectability<br />
Front key programming<br />
Front control buttons or<br />
PC software<br />
Specified when ordering or<br />
PC programming<br />
Front control buttons Specified when ordering Specified when ordering Specified when ordering<br />
No. of Alarm Point 2, 4 2, 4 1 2 2 2 1 or 2<br />
Relay Form Dual SPDT or Quad NO or NC Dual SPDT or Quad NO or NC SPDT SPDT SPDT SPDT SPDT or DPDT<br />
Alarm Setting<br />
Front key programming<br />
Front control buttons or<br />
PC software<br />
PC software Front control buttons 10-position rotary switches 270°-turn screwdrivers<br />
Three-turn screwdrivers,<br />
Remote dial potentiometer or<br />
DC input<br />
Alarm Setpoint 0 – 100% 0 – 100% -2 to +102% -14 to +113.5% 0 – 99% 0 – 100% 0 – 100%<br />
Deadband (Hysteresis) Adj. FS FS 0 – 99.9999% 0.5 – 15% – 1 – 100% 1 – 100%<br />
Latching Output Yes Yes – Yes – – Yes<br />
Setpoint Accuracy ±0.1% FS ±0.1% FS ±0.05% FS ±0.5% ±0.5% ±0.5% ±0.2%<br />
Alarm Test – Yes Yes – – – –<br />
DC Output – – – – – – Optional<br />
Power Input AC / DC AC / DC DC AC / DC AC / DC AC / DC AC / DC<br />
Operating Temperature<br />
-5 to +55°C<br />
-5 to +55°C<br />
-20 to +55°C<br />
-5 to +55°C<br />
-5 to +60°C<br />
-5 to +60°C<br />
-5 to +60°C<br />
(23 to 131°F)<br />
(23 to 131°F)<br />
(-4 to +131°F)<br />
(23 to 131°F)<br />
(23 to 140°F)<br />
(23 to 140°F)<br />
(23 to 140°F)<br />
Mounting Surface or DIN rail Surface or DIN rail DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail<br />
Surface<br />
(DIN rail available for 11-pin base)<br />
M6D/S : W5.9 × H94 × D102 mm<br />
W50 × H80 × D132 mm<br />
Dimensions<br />
W50 × H80 × D132 mm<br />
W29.5 × H83 × D124 mm<br />
(0.23” × 3.70” × 4.02”)<br />
W50 × H80 × D136 mm<br />
W50 × H80 × D132 mm<br />
W50 × H80 × D132 mm<br />
(1.97” × 3.15” × 5.20”)<br />
(1.97” × 3.15” × 5.20”)<br />
(1.16” × 3.27” × 4.88”) M6N : W7.5 × H102 × D102 mm<br />
(1.97” × 3.15” × 5.35”)<br />
(1.97” × 3.15” × 5.20”)<br />
(1.97” × 3.15” × 5.20”)<br />
W80 × H101 × D136 mm<br />
(0.30” × 4.02” × 4.02”)<br />
(3.15” × 3.98” × 5.35”)<br />
Standards & Approvals<br />
CE / UL / C-UL for selected models /<br />
RoHS for selected models<br />
CE / RoHS CE / RoHS CE / UL / C-UL RoHS for selected models – –<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Limit Alarms<br />
Product Selection Guide<br />
AS4 Series M7E-UNIT M6 Series MSEF AL-UNIT A-UNIT M-PAC<br />
DC Input AS4V M7EASV M6SXAS, M6NXAS, M6DXAS MSEF ALV ACV MP1000<br />
Thermocouple Input AS4T – M6SXAT, M6NXAT, M6DXAT – ALT ATC MP1200<br />
RTD Input AS4R – M6SXAR, M6NXAR, M6DXAR – ALR ARB MP1400<br />
Potentiometer Input AS4M – – – ALM APOT MP1800<br />
Two-wire Transmitter – M7EASDY – – ALDY, ALDN ADY, ADN MP1100<br />
Strain Gauge Input AS4LC – – – – – –<br />
AC Input – – – – ALTG, ALAC ATG, AAC MP1600<br />
PT Input – – – – ALPT APTA, APTE –<br />
CT Input AS4CT – – – ALCT ACTA, ACTE –<br />
Frequency Input – – – – ALSP ASP MP1700<br />
Others – – – – ALNR (Angle Sensor) ANR (Angle Sensor) –<br />
Front View<br />
Monitor<br />
LEDs<br />
DATA<br />
ALARM<br />
L4<br />
L3<br />
L2<br />
L1<br />
ITEM<br />
ITEM<br />
DATA<br />
DATA Display<br />
ITEM No.<br />
Display<br />
DATA UP-DOWN<br />
Keys<br />
ITEM No.<br />
UP-DOWN Keys<br />
Up Button<br />
Down Button<br />
Up<br />
Down<br />
Mode<br />
Set<br />
LCD Display<br />
Mode Button<br />
Set Button<br />
PC Configurator<br />
Jack<br />
Power LED<br />
Alarm Monitor LED<br />
Status Indicator LED<br />
Configurator Jack<br />
L1 Monitor<br />
LED<br />
L2 Monitor<br />
LED<br />
Digital Display<br />
UP Control<br />
DOWN Control<br />
MODE Selector<br />
No.1 LED<br />
No.1 Setpoint<br />
Rotary SW (x10%)<br />
No.1 Setpoint<br />
Rotary SW (x1%)<br />
No.2 Setpoint<br />
Rotary SW (x10%)<br />
No.2 Setpoint<br />
Rotary SW (x1%)<br />
No.2 LED<br />
Span Adj.<br />
Zero Adj.<br />
No.1 Setpoint Adj.<br />
No.1 LED<br />
No.1 Hysteresis<br />
(Deadband) Adj.<br />
No.2 Hysteresis<br />
(Deadband) Adj.<br />
No.2 LED<br />
No.2 Setpoint Adj.<br />
Span Adj.<br />
Zero Adj.<br />
No.1 Setpoint Adj.<br />
No.1 LED<br />
No.1 Hysteresis<br />
(Deadband) Adj.<br />
No.2 Hysteresis<br />
(Deadband) Adj.<br />
No.2 LED<br />
No.2 Setpoint Adj.<br />
Only typical models and specs are mentioned in this table. Please refer to the data sheet for detailed specs.<br />
424<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
425
426<br />
E<br />
Limit Alarms Product Selection Guide<br />
Limit Alarms Product Selection Guide<br />
E<br />
427<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
n Potentiometer / Dial Adjustments<br />
M2AVS KSE L4AS<br />
n Thumbwheel Switch Adjustments<br />
Extra DC Output<br />
AE-UNIT Series<br />
ASD1 KSED M2SED<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Indicators<br />
Limit Alarms<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Limit Alarms<br />
Product Selection Guide<br />
Construction Plug-in Plug-in<br />
Discrete box; terminal access at the<br />
front<br />
Plug-in Plug-in Plug-in Plug-in<br />
Connection M3 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3 screw terminal<br />
Isolation Input to output to power Input to output to power Input to output to power<br />
Input to DC output to relay output to<br />
power<br />
Input to output to power Input to output to power Input to output to power<br />
Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC<br />
Input Range Selectability Specified when ordering Specified when ordering Specified when ordering Specified when ordering Specified when ordering Specified when ordering Specified when ordering<br />
No. of Alarm Point 2 1, 2 2, 4 2 2 2 2<br />
Relay Form NO SPDT SPDT SPDT SPDT SPDT SPDT<br />
Alarm Setting Multi-turn screwdriver Dials Single-turn screwdrivers or dials Thumbwheel switches Thumbwheel switches Thumbwheel switches Thumbwheel switches<br />
Alarm Setpoint 0 – 100% -15 to +120% -15 to +115% 0 – 99% 0 – 99% 0 – 99% 0 – 99%<br />
Deadband (Hysteresis) Adj. – – – 9% 14% – –<br />
Latching Output – – – – Yes – –<br />
Setpoint Accuracy ±0.5% (monitor 0 – 1V) ±0.3% ±0.3% ±0.5% ±0.5% ±0.5% ±0.5%<br />
Alarm Test – – – – – – –<br />
DC Output – – – Yes – – –<br />
Power Input AC / DC AC AC / DC AC / DC AC AC AC / DC<br />
Operating Temperature<br />
-5 to +55°C<br />
(23 to 131°F)<br />
-5 to +55°C<br />
(23 to 131°F)<br />
-5 to +55°C<br />
(23 to 131°F)<br />
Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail<br />
Dimensions<br />
W23 × H76 × D124 mm<br />
(0.91” × 2.99” × 4.88”)<br />
KSE-x1: W50 × H80 × D136 mm<br />
(1.97” × 3.15” × 5.35”)<br />
KSE-x2: W50 × H80 × D145 mm<br />
(1.97” × 3.15” × 5.71”)<br />
W75 × H80 × D112 mm<br />
(2.95” × 3.15” × 4.41”)<br />
D126 mm (4.96”)<br />
with dial adjustments<br />
-5 to +55°C<br />
(23 to 131°F)<br />
W72 × H80 × D132 mm<br />
(2.83” × 3.15” × 5.20”)<br />
-5 to +60°C<br />
(23 to 140°F)<br />
W50 × H80 × D132 mm<br />
(1.97” × 3.15” × 5.20”)<br />
-5 to +55°C<br />
(23 to 131°F)<br />
W50 × H80 × D132 mm<br />
(1.97” × 3.15” × 5.20”)<br />
-5 to +55°C<br />
(23 to 131°F)<br />
W29.5 × H76 × D124 mm<br />
(1.16” × 2.99” × 4.88”)<br />
Standards & Approvals CE / RoHS CE RoHS – CE / UL / C-UL / RoHS CE / UL / C-UL / RoHS CE / UL / C-UL / RoHS<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Limit Alarms<br />
Product Selection Guide<br />
M2AVS KSE L4AS AE-UNIT ASD1 KSED M2SED<br />
DC Input M2AVS KSE-x1, KSE-x2 L4AS<br />
AEV,<br />
AEAD (two-input addition)<br />
ASD1 KSED M2SED<br />
Thermocouple Input – – – AET – – –<br />
RTD Input – – – AER – – –<br />
Potentiometer Input – – – AEM – – –<br />
Two-wire Transmitter – – – AEDY, AEDN – – –<br />
Strain Gauge Input – – – – – – –<br />
AC Input – – – AETG, AEAC – – –<br />
PT Input – – – AEPT – – –<br />
CT Input – – – AECT – – –<br />
Frequency Input – – – AESP – – –<br />
Others – – – – – – –<br />
■ Dial Adjustments<br />
■ KSE-x1<br />
■ Dial Adjustments<br />
Front View<br />
Output 1<br />
Setpoint<br />
Monitor (A1)<br />
Output 2<br />
Setpoint<br />
Monitor (A2)<br />
COM<br />
Output 1<br />
Setpoint Adj.<br />
Output 2<br />
Setpoint Adj.<br />
Output 1<br />
Monitor<br />
LED<br />
Output 2<br />
Monitor<br />
LED<br />
100<br />
50 %<br />
0<br />
■ KSE-x2<br />
100<br />
SET1<br />
50 %<br />
0<br />
100<br />
Hi Monitor LED<br />
Hi Setpoint Adj. Dial<br />
Hi Setpoint Adj. Dial<br />
Hi Monitor LED<br />
Lo Monitor LED<br />
Monitor LED<br />
Monitor LED<br />
1 2 3 4 Setpoint Adj.<br />
1 2 3 4 Setpoint Adj.<br />
■ Screwdriver Adjustments<br />
■ Screwdriver Adjustments<br />
Monitor LED<br />
Monitor LED<br />
1 2 3 4 Setpoint Adj.<br />
1 2 3 4 Setpoint Adj.<br />
9 9 9<br />
9 9 9<br />
• Output 1<br />
Setpoint Adj.<br />
Thumbwheel SW<br />
Hysteresis (Deadband)<br />
Adj. Thumbwheel SW<br />
Monitor LED<br />
Zero Adj.<br />
Span Adj.<br />
• Output 2<br />
Monitor LED<br />
Hysteresis (Deadband)<br />
Adj. Thumbwheel SW<br />
Setpoint Adj.<br />
Thumbwheel SW<br />
9 9<br />
9 9<br />
•Output 1<br />
Monitor LED<br />
Deadband &<br />
Latching Control<br />
Setpoint Adj.<br />
•Output 2<br />
Setpoint Adj.<br />
Monitor LED<br />
Deadband &<br />
Latching Control<br />
9 9<br />
9 9<br />
Hi Monitor LED<br />
Hi Setpoint Adj.<br />
Lo Setpoint Adj.<br />
Lo Monitor LED<br />
Output 1<br />
Setpoint Adj.<br />
Output 2<br />
Setpoint Adj.<br />
Output 1<br />
Monitor LED<br />
Output 2<br />
Monitor LED<br />
9 9<br />
9 9<br />
50 %<br />
SET2<br />
0<br />
Lo Setpoint Adj. Dial<br />
426<br />
Only typical models and specs are mentioned in this table. Please refer to the data sheet for detailed specs.<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 ISP ’12<br />
Specifications are subject to change without notice.<br />
427
428E<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Limit Alarms Product Selection Guide<br />
n Thumbwheel Switch Adjustments<br />
n Deviation Alarm<br />
M2AS M2AS1 AYDV<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Limit Alarms<br />
Product Selection Guide<br />
Construction Plug-in Plug-in Plug-in<br />
Connection M3 screw terminal M3 screw terminal M3.5 screw terminal<br />
Isolation Input to output to power Input to output to power Input to output to power<br />
Dielectric Strength 2000V AC 2000V AC 2000V AC<br />
Input Range Selectability Specified when ordering Specified when ordering Specified when ordering<br />
No. of Alarm Point 1 1 2<br />
Relay Form DPDT SPDT SPDT<br />
Alarm Setting Thumbwheel switches Thumbwheel switches Multi-turn screwdrivers<br />
Alarm Setpoint 0 – 99% 0 – 99% -50 to +50%<br />
Deadband (Hysteresis) Adj. FS FS –<br />
Latching Output Yes Yes –<br />
Setpoint Accuracy ±0.5% ±0.5% ±0.5%<br />
Alarm Test – – –<br />
DC Output – – –<br />
Power Input AC / DC AC / DC AC / DC<br />
Operating Temperature<br />
-5 to +55°C<br />
(23 to 131°F)<br />
-5 to +55°C<br />
(23 to 131°F)<br />
-5 to +60°C<br />
(23 to 140°F)<br />
Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail<br />
Dimensions<br />
W29.5 × H76 × D124 mm<br />
(1.16” × 2.99” × 4.88”)<br />
W23 × H76 × D124 mm<br />
(0.91” × 2.99” × 4.88”)<br />
W50 × H80 × D132 mm<br />
(1.97” × 3.15” × 5.20”)<br />
Standards & Approvals CE / RoHS CE / RoHS –<br />
M2AS M2AS1 AYDV<br />
DC Input M2AS M2AS1 AYDV<br />
Thermocouple Input – – –<br />
RTD Input – – –<br />
Potentiometer Input – – –<br />
Two-wire Transmitter – – –<br />
Strain Gauge Input – – –<br />
AC Input – – –<br />
PT Input – – –<br />
CT Input – – –<br />
Frequency Input – – –<br />
Others – – –<br />
Output<br />
Setpoint Adj.<br />
Setpoint 1<br />
Monitor<br />
Setpoint 2<br />
Monitor<br />
Deadband Adj.<br />
Deadband Adj.<br />
COM.<br />
9 9<br />
9 9<br />
Front View Setpoint 1<br />
Adj. & LED<br />
Output<br />
Monitor LED<br />
Reset Control<br />
9 9<br />
Output<br />
Setpoint Adj.<br />
Output<br />
Monitor LED<br />
Reset Control<br />
9 9<br />
Setpoint 2<br />
Adj. & LED<br />
428<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Gateway, Remote I/O<br />
Communicating directly to the<br />
PLC, DCS, HMI<br />
Designed to support great flexibilities in number and type of I/O signals.<br />
Working with open-architecture networks, these products easily communicate<br />
to today’s most popular HMI software packages and DCS/PLCs.<br />
ISP ’12<br />
429
F<br />
Signal Conditioners<br />
430 Gateway, Remote I/O Product Selection Guide<br />
Gateway, Remote I/O Product Selection Guide<br />
F 431<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Ultra-Slim, Mixed Signal Remote I/O<br />
P.432<br />
R6 Series<br />
Series and Features<br />
◆ Only 78 mm (3.07 in) wide with the minimum system of 8 modules<br />
(for R6S / R6D)<br />
◆ Selectable connection method – Tension-Clamp, Screw terminal or<br />
Euro terminal<br />
◆ Analog I/O range selectable with the built-in DIP switches<br />
◆ Low power consumption<br />
Expandable, Compact Remote I/O<br />
R7 Series<br />
P.433<br />
◆ Palm-top size compact module can handle 4 analog input,<br />
2 analog output or 8/16 discrete signals<br />
◆ 8 or 16 discrete input/output module can be attached to the base<br />
module<br />
◆ 1500 Vac isolation<br />
High-density remote I/O system<br />
using ultra-slim I/O modules.<br />
Analog and discrete signals can be<br />
mixed by combining a discrete I/O<br />
module with an analog module.<br />
External Dimensions mm (inch)<br />
■ R6S<br />
72 (2.83)<br />
116 (4.57)<br />
99 (3.90)<br />
<br />
<br />
■ R7C<br />
115 (4.53)<br />
54 (2.13)<br />
50 (1.97)<br />
30 (1.18)<br />
<br />
<br />
Networks<br />
<br />
<br />
LONWORKS<br />
R6<br />
R7<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Gateway, Remote I/O<br />
Product Selection Guide<br />
R6 Series<br />
R7 Series<br />
R3 Series<br />
R5 Series<br />
R1 Series<br />
60-UNIT Series<br />
61-UNIT Series<br />
M2BC / M2BD<br />
D3 Series<br />
DLA Series<br />
Gateway, Remote I/O<br />
Multi-channel, Mixed Signal Remote I/O<br />
R3 Series<br />
Compact, Mixed Signal Remote I/O<br />
R5 Series<br />
P.434<br />
◆ Wide selection of I/O modules including DC, AC,<br />
temperature, strain gauge, pulse trains, AC power, etc.<br />
◆ Selections of AC power, CT and VT modules suitable for<br />
energy monitoring applications<br />
◆ Dual redundant communication networks and power<br />
supplies<br />
P.434<br />
◆ Free combination of I/O modules, network modules and<br />
power modules<br />
◆ Dual redundant communication networks and power supplies<br />
◆ 2 fully-isolated analog I/O per module<br />
◆ Re-transmitted output modules suitable for extra field monitoring<br />
The removable terminal block is<br />
convenient for maintenance.<br />
The slanted I/O terminals are easily<br />
accessible even with high-density wiring.<br />
130 (5.12)<br />
90 (3.54)<br />
■ R3-BS08, R3-BSW08<br />
224 (8.82)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
■ R5-BS08, R5-BS09<br />
231 (9.09)<br />
<br />
<br />
<br />
<br />
<br />
<br />
120 (4.72)<br />
106.5 (4.19)<br />
<br />
<br />
<br />
<br />
R3<br />
LONWORKS<br />
-<br />
R5<br />
Gateway, Remote I/O<br />
Product Selection Guide<br />
Gateway, Remote I/O<br />
R6 Series<br />
R7 Series<br />
R3 Series<br />
R5 Series<br />
R1 Series<br />
60-UNIT Series<br />
61-UNIT Series<br />
M2BC / M2BD<br />
D3 Series<br />
DLA Series<br />
Compact, Multi-point Remote I/O<br />
R1 Series<br />
P.432<br />
◆ Economical all-in-one module for Modbus, DeviceNet and CC-Link<br />
◆ 12-point universal input module<br />
◆ 8-point RTD/Pot input module<br />
◆ 4-point totalized counter input, 8 contact I/O module<br />
◆ 32-point discrete I/O modules<br />
◆ Trigger contact input and alarm contact output<br />
105 (4.13)<br />
175 (6.89) 40 (1.57)<br />
<br />
<br />
·Except for RZ series<br />
Modbus<br />
R1<br />
HLS is the abbreviation for “High-speed Link <strong>System</strong>” of Step Technica Co., Ltd.<br />
430<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12 Specifications are subject to change without notice.<br />
ISP ’12 431
432F<br />
Gateway, Remote I/O R6 / R1 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
R6 Series<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
FUNCTION<br />
MODEL<br />
■ 8 I/O Slot Base<br />
x=S, N or D<br />
Base (8 I/O slots+ Network Module (18mm wide)) R6x-BS8A<br />
Base (8 I/O slots+ Network Module (36.5mm wide)) R6x-BS8B<br />
Base (8 I/O slots for extension)<br />
R6x-BS8P<br />
■ Power Module<br />
DC Power Supply Module<br />
R6x-PF1<br />
AC Power Supply Module<br />
R6-PSM<br />
■ Network Module<br />
Modbus<br />
32 ch. R6-NM1<br />
64 ch. R6-NM2<br />
Modbus/TCP (Ethernet)<br />
32 ch. R6-NE1<br />
64 ch. R6-NE2<br />
DeviceNet 64 ch. R6-ND1<br />
PROFIBUS-DP 62 ch. R6-NP1<br />
CC-Link<br />
Ver. 1.10; Analog 16 ch. R6-NC1<br />
Ver. 2.00; Analog 64 ch. R6-NC3<br />
T-Link<br />
R6-NF1<br />
FUNCTION CH MODEL<br />
■ Analog Input Module (isolated)<br />
x=S, N or D<br />
DC Voltage Input 2 R6x-SV2<br />
DC Current Input 2 R6x-SS2<br />
Thermocouple Input 2 R6x-TS2<br />
RTD Input 2 R6x-RS2<br />
4-20mA Input with Excitation 1 R6x-DS1<br />
■ Analog Output Module (isolated)<br />
DC Voltage Output 2 R6x-YV2<br />
DC Current Output 2 R6x-YS2<br />
■ Discrete Input Module<br />
Discrete Input Di 4 R6x-DA4<br />
■ Discrete Output Module<br />
NPN Transistor Output Do 4 R6x-DC4A<br />
PNP Transistor Output Do 4 R6x-DC4B<br />
■ Blank Filler Module<br />
Blank Filler Module --- R6x-DM<br />
Gateway, Remote I/O<br />
Product Selection Guide<br />
R1 Series<br />
R6S: tension clamp type<br />
R6N: screw terminal type<br />
R6D: euro terminal type<br />
R6 Series<br />
R7 Series<br />
R3 Series<br />
R5 Series<br />
R1 Series<br />
60-UNIT Series<br />
61-UNIT Series<br />
M2BC / M2BD<br />
Gateway, Remote I/O<br />
FUNCTION<br />
MODEL<br />
Universal Input Module (12 points; isolated) RZMS-U9 --- ---<br />
Thermocouple & DC Input Module (8 points; isolated) R1MS-GH3 --- ---<br />
Thermocouple & DC Input Module (16 points) R1M-GH R1D-GH2 R1C-GH<br />
RTD & Potentiometer Input Module (8 points) R1M-J3 --- ---<br />
Contact I/O Module<br />
(4 totalized counter inputs, 8 contact inputs and outputs)<br />
R1M-P4 --- ---<br />
Contact Input Module (32 points) R1M-A1 --- ---<br />
Contact Output Module (32 points) R1M-D1 --- ---<br />
D3 Series<br />
DLA Series<br />
432<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Gateway, Remote I/O R7 Series<br />
F 433<br />
Signal Conditioners<br />
R7 Series<br />
Two-wire<br />
Signal Conditioners<br />
FUNCTION<br />
MODEL<br />
FLEX NETWORK<br />
Power Transducers<br />
■ Basic Module<br />
Indicators<br />
Discrete Input, 16 points R7M-DA16 R7E-DA16 R7D-DA16 R7C-DA16 R7L-DA16* 1 R7ML-DA16 R7FN-DA16 R7HL-DA16<br />
NPN Transistor Output,<br />
16 points<br />
R7M-DC16A R7E-DC16A R7D-DC16A R7C-DC16A* 5 R7L-DC16A* 2 R7ML-DC16A R7FN-DC16A R7HL-DC16A<br />
PNP Transistor Output,<br />
16 points<br />
R7M-DC16B R7E-DC16B R7D-DC16B R7C-DC16B* 5 R7L-DC16B* 2 R7ML-DC16B R7FN-DC16B R7HL-DC16B<br />
Discrete Input &<br />
NPN Transistor Output,<br />
--- --- --- --- R7L-DAC16* 3 --- R7FN-DAC16A R7HL-DAC16A<br />
8 points each<br />
Discrete Input &<br />
PNP Transistor Output,<br />
--- --- --- --- --- --- R7FN-DAC16B R7HL-DAC16B<br />
8 points each<br />
Independent I/O Common<br />
Discrete Input &<br />
NPN Transistor Output,<br />
--- --- --- --- --- --- --- R7HL-DAC16ES<br />
8 points each<br />
Relay Contact Output, 8 points R7M-DC8C* 6 --- R7D-DC8C* 6 R7C-DC8C* 6 --- --- R7FN-DC8C R7HL-DC8C<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Relay Contact Output, 8 points --- --- --- R7C-DC8E* 5 --- --- --- ---<br />
Remote Control Relay Control,<br />
4 points<br />
Remote Control Relay Control,<br />
8 points<br />
--- --- --- R7C-RR4* 6 --- --- --- ---<br />
--- --- --- --- R7L-RR8* 4 --- --- ---<br />
DC Voltage / Current Input,<br />
4 points<br />
DC Voltage / Current Input,<br />
4 points<br />
(high speed, non-isolated)<br />
R7M-SV4 R7E-SV4 R7D-SV4 R7C-SV4 R7L-SV4* 4 R7ML-SV4 R7FN-SV4 R7HL-SV4<br />
--- --- --- --- --- --- R7FN-SVF4 R7HL-SVF4<br />
Thermocouple Input, 4 points R7M-TS4 R7E-TS4 R7D-TS4 R7C-TS4 R7L-TS4* 4 R7ML-TS4 R7FN-TS4 R7HL-TS4<br />
RTD Input, 4 points R7M-RS4 R7E-RS4 R7D-RS4 R7C-RS4 R7L-RS4* 4 R7ML-RS4 R7FN-RS4 R7HL-RS4<br />
Thermistor Input, 4 points --- --- --- R7C-RT4A --- --- --- ---<br />
Potentiometer Input, 4 points R7M-MS4 R7E-MS4 R7D-MS4 R7C-MS4 --- --- --- ---<br />
AC Current Input, 4 points R7M-CT4E R7E-CT4E R7D-CT4E R7C-CT4E --- --- --- ---<br />
DC Voltage Output, 2 points R7M-YV2 R7E-YV2 R7D-YV2(A) R7C-YV2 R7L-YV2* 4 R7ML-YV2 R7FN-YV2 R7HL-YV2<br />
DC Current Output, 2 points R7M-YS2 R7E-YS2 R7D-YS2(A) R7C-YS2 R7L-YS2* 4 R7ML-YS2 R7FN-YS2 R7HL-YS2<br />
■ Extension Module<br />
Discrete Input, 8 points R7M-EA8 R7E-EA8 R7D-EA8 R7C-EA8 R7L-EA8 R7ML-EA8 --- ---<br />
Discrete Input, 16 points R7M-EA16 R7E-EA16 R7D-EA16 R7C-EA16 R7L-EA16 R7ML-EA16 --- ---<br />
NPN Transistor Output,<br />
8 points<br />
NPN Transistor Output,<br />
16 points<br />
PNP Transistor Output,<br />
8 points<br />
PNP Transistor Output,<br />
16 points<br />
R7M-EC8A R7E-EC8A R7D-EC8A R7C-EC8A R7L-EC8A R7ML-EC8A --- ---<br />
R7M-EC16A R7E-EC16A R7D-EC16A R7C-EC16A R7L-EC16A R7ML-EC16A --- ---<br />
R7M-EC8B R7E-EC8B R7D-EC8B R7C-EC8B R7L-EC8B R7ML-EC8B --- ---<br />
R7M-EC16B R7E-EC16B R7D-EC16B R7C-EC16B R7L-EC16B R7ML-EC16B --- ---<br />
Relay Contact Output, 8 points --- --- --- R7C-EC8C --- --- --- ---<br />
Gateway, Remote I/O<br />
Product Selection Guide<br />
Gateway, Remote I/O<br />
R6 Series<br />
R7 Series<br />
R3 Series<br />
R5 Series<br />
R1 Series<br />
60-UNIT Series<br />
61-UNIT Series<br />
M2BC / M2BD<br />
D3 Series<br />
DLA Series<br />
■ Gateway Module<br />
Gateway Module<br />
R7G<br />
*1: Momentary or totalized pulse input<br />
*2: One-shot output available<br />
*3: Momentary or totalized pulse input, one-shot output available<br />
*4: Totalized pulse input is available when input extension module is connected<br />
*5: Selectable with extension modules R7C-ECxA, R7C-ECxB, R7C-EC8C<br />
*6: Not usable with extension modules<br />
HLS is the abbreviation for “High-speed Link <strong>System</strong>” of Step Technica Co., Ltd.<br />
ISP ’12 Specifications are subject to change without notice.<br />
433
434F<br />
Gateway, Remote I/O R3 / R5 Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Gateway, Remote I/O<br />
Product Selection Guide<br />
R6 Series<br />
R7 Series<br />
R3 Series<br />
R5 Series<br />
R1 Series<br />
60-UNIT Series<br />
61-UNIT Series<br />
M2BC / M2BD<br />
D3 Series<br />
DLA Series<br />
434<br />
Gateway, Remote I/O<br />
FUNCTION CH MODEL CH MODEL<br />
■ Base<br />
Installation Base R3-BS R5-BS<br />
Installation Base<br />
(free I/O address)<br />
R3-BSW ---<br />
Extender Power Module Base --- R5-EX1<br />
■ Power Module<br />
Power<br />
750mA R3-PS1 ---<br />
Supply 1.5A --- R5-PS<br />
Module<br />
2A R3-PS3 ---<br />
■ Network Module<br />
Modbus R3-NM1 R5-NM1<br />
Modbus/TCP (Ethernet) R3-NE1 R5-NE1<br />
Analog 16 ch. R3-ND1 R5-ND1<br />
DeviceNet Analog 32 ch. R3-ND2 R5-ND2<br />
Analog 64 ch. R3-ND3 ---<br />
DPV1 R3-NP1 ---<br />
PROFIBUS Analog 16 ch. --- R5-NP1<br />
Analog 32 ch. --- R5-NP2<br />
Ver. 1.10;<br />
Analog 16 ch.<br />
R3-NC1<br />
R5-NC1<br />
CC-Link Ver. 1.10;<br />
Analog 32 ch.<br />
R3-NC2<br />
R5-NC2<br />
Ver.2 R3-NC3 ---<br />
LONWORKS<br />
R3-NL1 ---<br />
R3-NL2 ---<br />
T-Link R3-NF1 R5-NF1<br />
FL-net R3-NFL1 ---<br />
■ Network Module (gateway)<br />
Modbus (Ver. 1.10) R3-GM1 ---<br />
Modbus/TCP (Ethernet) R3-GE1 ---<br />
DeviceNet Analog 64 ch. R3-GD1 ---<br />
CC-Link (Ver. 1.10/2.00) R3-GC1 ---<br />
FL-net (OPCN-2) R3-GFL1 ---<br />
■ Analog Input Module (isolated)<br />
Universal Input 4 R3-US4 --- ---<br />
4 R3-SV4<br />
R5-SV1<br />
4<br />
1<br />
millivolt Input R3-SV4A R5T-SV1<br />
DC Voltage Input<br />
R3 Series R5 Series R3 Series R5 Series<br />
4<br />
wide span<br />
voltage<br />
8<br />
R3-SV4B<br />
R5-SV2<br />
2<br />
R3-SV4C<br />
R5T-SV2<br />
R3-SV8 --- ---<br />
R3Y-SV8 --- ---<br />
8<br />
millivolt Input R3-SV8A --- ---<br />
8<br />
wide span<br />
voltage<br />
8<br />
non-isolated<br />
16<br />
non-isolated<br />
R3-SV8B --- ---<br />
R3-SV8C --- ---<br />
R3-SV8N --- ---<br />
R3Y-SV8N --- ---<br />
R3S-SV8N --- ---<br />
R3-SV16N --- ---<br />
R3Y-SV16N --- ---<br />
R3S: tension-clamp type<br />
R3Y: connector type<br />
R5T: screw terminal block type<br />
FUNCTION CH MODEL CH MODEL<br />
4 R3-SS4<br />
R5-SS1<br />
1<br />
R3-SS8<br />
R5T-SS1<br />
8<br />
R3Y-SS8<br />
R5-SS2<br />
2<br />
DC Current Input<br />
R3-SS8N<br />
R5T-SS2<br />
8<br />
non-isolated R3Y-SS8N --- ---<br />
R3S-SS8N --- ---<br />
16 R3-SS16N --- ---<br />
non-isolated<br />
R3Y-SS16N --- ---<br />
4 R3-TS4<br />
R5-TS1<br />
1<br />
Thermocouple Input<br />
8 R3-TS8 R5T-TS1<br />
--- ---<br />
R5-TS2<br />
2<br />
--- --- R5T-TS2<br />
4 R3-RS4<br />
R5-RS1<br />
1<br />
4 R3-RS4A<br />
R5T-RS1<br />
high accuracy<br />
R3S-RS4A<br />
R5-RS2<br />
2<br />
RTD Input<br />
8<br />
R3-RS8<br />
R5T-RS2<br />
1<br />
R3Y-RS8 high resolution R5-RSA1<br />
8<br />
high accuracy<br />
2<br />
R3-RS8A high resolution R5-RSA2<br />
R3-RS8B --- ---<br />
4 R3-MS4 1 R5-MS1<br />
Potentiometer Input<br />
R3-MS8 2 R5-MS2<br />
8<br />
R3Y-MS8 --- ---<br />
R3-DS4<br />
R5-DS1<br />
4<br />
1<br />
4-20mA Input<br />
R3-DS4A<br />
R5T-DS1<br />
with Excitation<br />
8 R3-DS8N<br />
R5-DS2<br />
2<br />
non-isolated<br />
R3Y-DS8N<br />
R5T-DS2<br />
Strain Gauge Input 2 R3-LC2 --- ---<br />
CT Input<br />
4 R3-CT4 1 R5T-CT1<br />
--- --- 2 R5T-CT2<br />
Zero-phase Current Input 4 R3-CZ4 --- ---<br />
R3-CT4A 1 R5T-CTA1<br />
4 R3-CT4B 2 R5T-CTA2<br />
AC Current Input<br />
R3-CT4C --- ---<br />
(clamp-on current sensor use)<br />
R3-CT8A 1 R5T-CTB1<br />
8 R3-CT8B 2 R5T-CTB2<br />
R3-CT8C --- ---<br />
AC Voltage Input<br />
4 R3-PT4 1 R5T-PT1<br />
--- --- 2 R5T-PT2<br />
4<br />
AC Power Input<br />
input circuits R3-WT4 --- ---<br />
AC Power Input<br />
4 R3-WT4A --- ---<br />
(clamp-on current sensor use) input circuits<br />
R3-WT4B --- ---<br />
Multi Power Input 1 system R3-WT1 --- ---<br />
R3-WT1A --- ---<br />
1 system<br />
Multi Power Input<br />
R3-WT1B --- ---<br />
(clamp-on current sensor use)<br />
1 or 2<br />
system R3-WTU --- ---<br />
R3S: tension-clamp type<br />
R3Y: connector type<br />
R5T: screw terminal block type<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Gateway, Remote I/O R3 / R5 Series<br />
R3 Series R5 Series R3 Series R5 Series<br />
F 435<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
FUNCTION CH MODEL CH MODEL<br />
■ Analog Output Module (isolated)<br />
R3-YV4<br />
R5-YV1<br />
DC Voltage Output<br />
4<br />
1<br />
R3S-YV4<br />
R5T-YV1<br />
R3-YV8<br />
R5-YV2<br />
R3Y-YV8<br />
8<br />
2<br />
R5T-YV2<br />
R3-YS4<br />
R5-YS1<br />
1<br />
DC Current Output<br />
4 R3Y-YS4<br />
R5T-YS1<br />
R3S-YS4<br />
R5-YS2<br />
2<br />
--- --- R5T-YS2<br />
■ Pulse I/O Module (isolated)<br />
R3-PA8<br />
R5-PA2<br />
Totalized Pulse Input<br />
Pi 8<br />
Pi 2<br />
R3S-PA8<br />
R5T-PA2<br />
R3-PA16 --- ---<br />
Pi 16<br />
R3Y-PA16 --- ---<br />
High Speed Totalized Pulse Input Pi 4 R3-PA4A --- ---<br />
Low Speed Totalized Pulse Input Pi 4 R3-PA4B --- ---<br />
High Speed Pulse Input Pi 4 R3-PA4 --- ---<br />
Encoder Input Pi 2 R3-PA2 --- ---<br />
Pulse Output<br />
Po 16 R3-PC16A<br />
R5-PC2<br />
Po 2<br />
--- --- R5T-PC2<br />
■ Analog Input Module with Transmitter Output (isolated)<br />
DC Voltage Input --- --- 1 R5-SV1A<br />
DC Current Input --- --- 1 R5-SS1A<br />
Thermocouple Input --- --- 1 R5-TS1A<br />
RTD Input --- --- 1 R5-RS1A<br />
Potentiometer Input --- --- 1 R5-MS1A<br />
4-20mA Input with Excitation --- --- 1 R5-DS1A<br />
■ Alarm Module (isolated)<br />
DC Voltage Input<br />
4 R3-AV4 --- ---<br />
8 R3-AV8 --- ---<br />
DC Current Input<br />
4 R3-AS4 --- ---<br />
8 R3-AS8 --- ---<br />
Thermocouple Input 4 R3-AT4 --- ---<br />
RTD Input 4 R3-AR4 --- ---<br />
4-20mA Input with Excitation 4 R3-AD4 --- ---<br />
R3S: tension-clamp type<br />
R3Y: connector type<br />
R5T: screw terminal block type<br />
FUNCTION CH MODEL CH MODEL<br />
■ Discrete I/O Module<br />
R3-DA16<br />
R5-DA4<br />
Di 4<br />
Discrete Input Di 16 R3Y-DA16<br />
R5T-DA4<br />
R3S-DA16 Di 16 R5-DA16<br />
R3-DA16A --- ---<br />
Di 16<br />
Discrete Input<br />
R3Y-DA16A --- ---<br />
(with excitation supply) Di 32 R3-DA32A --- ---<br />
Di 64 R3-DA64A --- ---<br />
AC Contact Input Di 16 R3-DA16B --- ---<br />
Discrete Input / Output Di 8, Do 8<br />
R3-DAC16 --- ---<br />
R3S-DAC16 --- ---<br />
Discrete Input / Output Di 8, Do 8<br />
R3-DAC16A --- ---<br />
R3S-DAC16A --- ---<br />
Relay Contact Output Do 16<br />
R3-DC16<br />
R5-DC4<br />
Do 4<br />
R3Y-DC16<br />
R5T-DC4<br />
Do 16 R3-DC16A Do 16 R5-DC16<br />
Open Collector Output<br />
(NPN transistor)<br />
Do 32 R3-DC32A --- ---<br />
Do 64 R3-DC64A --- ---<br />
Triac Output Do 16 R3-DC16B --- ---<br />
Do 16 R3-DC16C --- ---<br />
PNP Transistor Output Do 32 R3-DC32C --- ---<br />
Do 64 R3-DC64C --- ---<br />
One-shot Pulse Output<br />
(relay contact)<br />
Do 16 R3-PD16 --- ---<br />
One-shot Pulse Output<br />
(NPN transistor)<br />
Do 16 R3-PD16A --- ---<br />
One-shot Pulse Output<br />
(triac)<br />
Do 16 R3-PD16B --- ---<br />
One-shot Pulse Output<br />
(PNP transistor)<br />
Do 16 R3-PD16C --- ---<br />
Remote Control Relay<br />
R3-RR8 --- ---<br />
Do 8<br />
Control<br />
R3S-RR8 --- ---<br />
■ BCD Code I/O Module<br />
BCD Code Input 7-digit BCD R3-BA32A --- ---<br />
BCD Code Output 7-digit BCD R3-BC32A --- ---<br />
■ Blank Filler Module<br />
Blank Filler Module --- R3-DM --- R5-DM<br />
R3S: tension-clamp type<br />
R3Y: connector type<br />
R5T: screw terminal block type<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Gateway, Remote I/O<br />
Product Selection Guide<br />
Gateway, Remote I/O<br />
R6 Series<br />
R7 Series<br />
R3 Series<br />
R5 Series<br />
R1 Series<br />
60-UNIT Series<br />
61-UNIT Series<br />
M2BC / M2BD<br />
D3 Series<br />
DLA Series<br />
ISP ’12 Specifications are subject to change without notice.<br />
435
436 F<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Other Remote I/O Series<br />
Field Network Modules<br />
60-UNIT Series<br />
Interfacing analog I/O signals from/to 10-RACK or<br />
18-RACK modules<br />
◆◆Palm-top size plug-in module<br />
60-UNIT<br />
Field Network Modules<br />
61-UNIT Series<br />
Interfacing analog I/O signals from/to Mini-M or<br />
Pico-M modules<br />
◆◆Palm-top size plug-in module<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
61-UNIT<br />
Gateway, Remote I/O<br />
Product Selection Guide<br />
R6 Series<br />
R7 Series<br />
R3 Series<br />
R5 Series<br />
R1 Series<br />
60-UNIT Series<br />
61-UNIT Series<br />
M2BC / M2BD<br />
Gateway, Remote I/O<br />
Communication Controllers<br />
M2BC / M2BD<br />
Wide selection of Mini-M series signal<br />
conditioner inputs<br />
◆◆CC-Link and DeviceNet interface<br />
◆◆Direct interface of various field signals including AC<br />
energy and pneumatic to a PLC<br />
◆◆Power supply to individual modules via the<br />
backplane bus<br />
D3 Series<br />
DLA Series<br />
D3 Series<br />
Max. 10 km Transmission via Twisted-pair Cable<br />
◆◆Simple I/O module configuration<br />
◆◆No software programming required<br />
◆◆Interfacing field signals to the host PLC via Modbus<br />
RTU or Modbus/TCP<br />
◆◆Free combination of I/O signals<br />
Multiplex Transmission <strong>System</strong><br />
DLA Series<br />
Simple Setting, Masterless Configuration<br />
◆◆Simple setting by matching the station address of<br />
paired modules<br />
◆◆No total system failure thanks to the masterless<br />
configuration<br />
◆◆All-in-one unit packaging I/O, power and network<br />
interface modules<br />
436<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Paperless Recording <strong>System</strong><br />
Versatile data recording and<br />
intuitive operation<br />
Replace paper chart recorders and save cost of supplies and maintenance.<br />
Flexible I/O and networking capabilities.<br />
ISP ’12<br />
437
G<br />
438<br />
Paperless Recorder<br />
73VR Series<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Replace paper chart recorders and save cost of supplies and maintenance.<br />
Environmentally friendly data recording solution – no chart paper, pens and cartridges.<br />
73VR Series offers 3 types to select in many applications.<br />
Versatile data recording.<br />
◆◆<br />
Touch panel operation<br />
◆◆<br />
Selectable number of pens to display<br />
◆◆<br />
5.5-inch TFT color display with backlight<br />
◆◆<br />
Selectable chart colors available<br />
White or from blue to black (plain light, plain dark or gradation)<br />
◆◆<br />
IP65 front cover<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Remote I/O type<br />
73VR1100<br />
Built-in<br />
universal input type<br />
73VR2100<br />
Selectable input<br />
module type<br />
73VR3100<br />
73VR Series<br />
73VR3100<br />
73VR2100<br />
73VR1100<br />
71VR1<br />
Paperless Recording <strong>System</strong><br />
73VR1100 73VR2100<br />
New Feature of Paperless Recorder 73VR3100<br />
Direct operation and configuration from PLC<br />
73VR3100<br />
NEW<br />
◆◆<br />
The host PLC can control the 73VR3100 via built-in gateway<br />
module to start/stop recording, enter comments and set<br />
displays. *1<br />
◆◆<br />
Data sent from PLC can be displayed and recorded. *2<br />
*1. In “Remote” mode, local control at the 73VR3100 is locked<br />
*2. Storing rate 20msec. is not selectable<br />
Operator Panel<br />
■ Gateway Interface Modules *3<br />
Network Model Function<br />
PLC<br />
Data<br />
Operation<br />
Operation, Data<br />
R3-GC1 Ver. 2.00<br />
R3-GD1<br />
Analog 64 ch.<br />
Modbus/TCP R3-GE1 Ethernet<br />
Data<br />
Open Network<br />
Modbus R3-GM1 RS-485<br />
-<br />
R3-GFL1 OPCN-2<br />
73VR3100<br />
*3. The number of gateway module vary by its settings<br />
Input<br />
Input<br />
438<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Paperless Recorder with selectable built-in I/O 73VR3100<br />
G<br />
439<br />
Signal Conditioners<br />
n Paperless Recorder with selectable built-in I/O 73VR3100<br />
Selectable input modules.<br />
Flexible I/O capability using<br />
the R3 series modules.<br />
Compatible with various open networks.<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
5.5-inch TFT LCD<br />
touch panel screen<br />
Network / Gateway<br />
modules<br />
◆◆<br />
Up to four R3 Series I/O modules can be selected (Max. 64 inputs).<br />
◆◆<br />
By replacing one of the I/O modules with Network Module for the R3 Series, the 73VR3100 can directly<br />
communicate to major PLC via Modbus, Ethernet (Modbus/TCP), DeviceNet, PROFIBUS-DP, CC-Link,<br />
LONWORKS, T-Link and FL-net.<br />
◆◆<br />
20 msec. storing rate with the combination of 8 analog and 8 discrete inputs.<br />
◆◆<br />
Real time trending and recording on the PC Recorder software MSR via Ethernet.<br />
Selectable I/O modules<br />
(max. 4)<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SPECIFICATIONS<br />
Number of input channels 4 through 64<br />
Function pen points 16, 64<br />
Storing rate<br />
(high speed mode)<br />
20 msec., 100 msec.<br />
Storing rate<br />
(normal mode)<br />
Input types<br />
Trigger input<br />
Alarm/Run output<br />
Weight<br />
Display<br />
• Display device<br />
500 msec., 1, 2, 5, 10 seconds, 1minute,<br />
10 minutes<br />
R3 series I/O modules<br />
(DC voltage, DC current, Thermocouple, RTD,<br />
AC voltage, AC current, Encoder, Totalized pulse, Di/o)<br />
Max. 64 (depending on input modules types)<br />
Max. 32 (depending on input modules types)<br />
2.3 kg (5.1 lbs) except I/O modules<br />
5.5-inch TFT LCD<br />
• Display colors 256<br />
• Resolution<br />
320 × 240 pixels<br />
10BASE-T / 100BASE-TX automatically switched;<br />
Ethernet<br />
Conforms to IEEE802 (10BASE-T) or IEEE802.3<br />
(100BASE-TX)<br />
IP65<br />
(applicable to the front panel of with the cover<br />
Degree of protection<br />
closed when a single unit is mounted according to<br />
the specified panel cutout)<br />
CE marking –<br />
Open network module installed,<br />
using 73VR3100 as remote I/O with local<br />
display and recording function.<br />
PLC<br />
73VR3100<br />
PLC<br />
CPU<br />
Input<br />
Open Network<br />
Input<br />
Display & recording data input to a control system<br />
Recorder Operator Panel Operator Panel<br />
PLC<br />
Paperless Recording <strong>System</strong><br />
73VR Series<br />
73VR3100<br />
73VR2100<br />
73VR1100<br />
71VR1<br />
Open<br />
Network<br />
Isolator<br />
73VR3100<br />
Input<br />
Input<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
439
G<br />
440 Paperless Recorder with built-in I/O 73VR2100<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
n Paperless Recorder with built-in I/O 73VR2100<br />
Built-in universal input modules.<br />
Universal input – DC, Thermocouple, RTD<br />
◆◆<br />
Independent input type and range selectable for<br />
each channel<br />
◆◆<br />
100 msec. storing rate up to 6 point<br />
◆◆<br />
2, 4, 6, 8, 10 or 12 points<br />
◆◆<br />
Real time trending and recording on the PC Recorder<br />
software MSR via Ethernet<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
73VR Series<br />
73VR3100<br />
73VR2100<br />
73VR1100<br />
71VR1<br />
Paperless Recording <strong>System</strong><br />
SPECIFICATIONS INPUT TYPE<br />
Number of input channels 2, 4, 6, 8, 10 or 12<br />
Function pen points 12<br />
Storing rate<br />
(high speed mode)<br />
100 msec.<br />
Storing rate<br />
(normal mode)<br />
Input types<br />
500 msec., 1, 2, 5, 10 seconds, 1minute,<br />
10 minutes<br />
Universal input<br />
(DC mV and voltage, thermocouple, 3-wire RTD)<br />
Trigger input Dry contact × 1<br />
Alarm/Run output Relay contact × 1<br />
Weight<br />
2.4 kg (5.3 lbs)<br />
Display<br />
• Display device 5.5-inch TFT LCD<br />
• Display colors 256<br />
• Resolution<br />
320 × 240 pixels<br />
10BASE-T / 100BASE-TX automatically switched;<br />
Ethernet<br />
Conforms to IEEE802 (10BASE-T) or IEEE802.3<br />
(100BASE-TX)<br />
IP65<br />
Degree of protection<br />
(applicable to the front panel of with the cover<br />
closed when a single unit is mounted according to<br />
the specified panel cutout)<br />
CE marking<br />
Yes<br />
QUICK SETUP<br />
DC Voltage<br />
DC Current<br />
Thermocouple<br />
RTD (3-wire)<br />
Model<br />
Input resistance 900kΩ minimum (Excluding the case in<br />
which, with range setting other than<br />
±12V, ±6V or ±3V, a voltage exceeding<br />
±1.3V is applied.)<br />
Input range ±60mV, ±125mV, ±250mV, ±500mV,<br />
±1000mV, ±3V, ±6V, ±12V<br />
4-20mA, use optional REM3-250 resistor module<br />
Input range (PR), K (CA), E (CRC), F (IC), T (CC),<br />
B (RH), R, S, C (WRe 5-26), N, U, L,<br />
P (Platinel II)<br />
Burnout sensing • Upscale: ≤130nA<br />
• Downscale: ≤220nA<br />
• No burnout: ≤10nA<br />
Input range Pt 100 (JIS ’89), Pt 100 (JIS ’97, IEC),<br />
Pt 200, Pt 300, Pt 400, Pt 500, Pt 1000,<br />
Pt 50Ω (JIS ’81), JPt 100 (JIS ’89),<br />
Ni 100, Ni 120, Ni 508.4Ω, Ni-Fe 604,<br />
Cu 10 @25°C<br />
Burnout sensing Upscale or Downscale: ≤130nA<br />
Allowable leadwire<br />
20Ω per wire<br />
resistance<br />
73VR2102<br />
73VR2104<br />
73VR2106<br />
73VR2108<br />
73VR2110<br />
73VR2112<br />
Function<br />
Paperless Recorder<br />
(built-in input modules, 2-point inputs)<br />
Paperless Recorder<br />
(built-in input modules, 4-point inputs)<br />
Paperless Recorder<br />
(built-in input modules, 6-point inputs)<br />
Paperless Recorder<br />
(built-in input modules, 8-point inputs)<br />
Paperless Recorder<br />
(built-in input modules, 10-point inputs)<br />
Paperless Recorder<br />
(built-in input modules, 12-point inputs)<br />
Intuitive “Help View” screen for easy user setup and use.<br />
440<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
n Paperless Recorder with Remote I/O 73VR1100<br />
Paperless Recorder with Remote I/O 73VR1100<br />
Connects to remote I/O.<br />
Designed to utilize a wide variety of M-<strong>System</strong>'s remote I/O devices.<br />
◆◆<br />
Best suited to record data transmitted from I/O located remotely in the field, or inside an instrumentation or<br />
control cabinet.<br />
◆◆<br />
Instead of using expensive sensor cables, reduce wiring runs by using open field networks through remote I/O.<br />
◆◆<br />
I/O separated 73VR1100 provides the installation flexibility which fits in the tight space of a control panel or<br />
machinery chassis.<br />
G441<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
73VR1100<br />
R3 Series<br />
R7 Series<br />
SPECIFICATIONS<br />
Number of input channels 64, 128 (Function pen points included)<br />
Function pen points 32, 64<br />
Storing rate<br />
(high speed mode)<br />
100 msec.<br />
Storing rate<br />
(normal mode)<br />
Input types<br />
Trigger input<br />
Alarm/Run output<br />
Weight<br />
Display<br />
• Display device<br />
500 msec., 1, 2, 5, 10 seconds, 1minute,<br />
10 minutes<br />
R3 series I/O modules<br />
(DC voltage, DC current, Thermocouple, RTD,<br />
AC voltage, AC current, Encoder, Totalized pulse)<br />
Max. 128 via remote I/O<br />
Alarm × 1, Run × 1; Alarm also available via<br />
remote output modules<br />
1.7 kg (3.7 lbs)<br />
5.5-inch TFT LCD<br />
• Display colors 256<br />
• Resolution<br />
320 × 240 pixels<br />
10BASE-T / 100BASE-TX automatically switched;<br />
Ethernet<br />
Conforms to IEEE802 (10BASE-T) or IEEE802.3<br />
(100BASE-TX)<br />
IP65<br />
(applicable to the front panel of with the cover<br />
Degree of protection<br />
closed when a single unit is mounted according to<br />
the specified panel cutout)<br />
CE marking<br />
Yes<br />
Multichannel remote data acquisition<br />
73VR1100<br />
Up to 128 points<br />
Max. 500 meters<br />
Modbus RS-485<br />
Remote I/O<br />
Reduce wiring cost<br />
Up to 15 remote I/O<br />
Ethernet - Up to 2 stations<br />
73VR1100<br />
Paperless Recording <strong>System</strong><br />
73VR Series<br />
73VR3100<br />
73VR2100<br />
73VR1100<br />
71VR1<br />
Remote I/O<br />
Sensor Sensor Sensor Sensor<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
441
G<br />
442<br />
Compact Paperless Recorder<br />
71VR1<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
◆◆1/4 DIN size (96 x 96 mm) panel mount compact recorder<br />
◆◆3.5 inch TFT color LCD display<br />
◆◆<br />
Max. 8-point each of analog and discrete inputs are stored,<br />
displayed and alerted.<br />
◆◆Max. 8-point discrete outputs can be assigned for alarm trips.<br />
◆◆Direct field inputs at the built-in terminals and<br />
optional remote inputs via Modbus RTU<br />
◆◆Data can be transferred to PC via the front IR port<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
FUNCTION<br />
Di x 2, Do x 2 and Modbus<br />
Di x 2, Do x 2 and Modbus<br />
+ DC mA/V input x 2<br />
Di x 2, Do x 2 and Modbus<br />
+ DC mA/V input x 2 + Universal input x 3<br />
MODEL<br />
71VR1-E001<br />
71VR1-E101<br />
71VR1-E501<br />
Trend Graph<br />
Alarm History<br />
73VR Series<br />
73VR3100<br />
73VR2100<br />
73VR1100<br />
71VR1<br />
Paperless Recording <strong>System</strong><br />
M-<strong>System</strong>’s Model 71VR1 is a 1/4 DIN size (96 x 96 mm panel cutout), compact paperless recorder that can store and<br />
display the maximum of 8-point analog inputs and 8-point discrete inputs. The 3.5 inch TFT color LCD display can show<br />
two pen channels at once on a trend graph or digital/bargraph indicators.<br />
Field signals are connected to local terminals and polled remotely from Modbus RTU I/O devices. Three models are<br />
available depending on the number of local inputs.<br />
Data sampling rate is selectable between 100 msec. and 10 seconds depending upon the type and number of local<br />
and remote inputs. In addition to manual and continuous recording mode, conditional recording triggered by AND/<br />
OR functions in combinations of analog/discrete signal values/states is available. This allows the user to record only<br />
necessary part of the data in order to save memory area.<br />
Each analog input signal is independently set with four (4) alarm thresholds. In addition to the built-in DO terminals, at<br />
the maximum of 8-point discrete outputs can be mapped on remote output devices to alert externally. Alarm events are<br />
recorded in an alarm history file, up to 200 events.<br />
Data is stored in a memory card at the rear side of the recorder, and can be transferred to a PC and converted into CSV<br />
format files with this card or via the front IrDA port.<br />
Thanks to its small panel size and shallow depth of only 10 centimeters (4 inches) needed behind the panel surface, the<br />
71VR1 can be mounted on control panels built into industrial and commercial machineries. Imagine the 71VR1 mounted<br />
on a wave soldering machine. Single unit can monitor and record solder temperature, conveyor speed, starting/stopping<br />
of the machine, current consumption and their alarm history.<br />
IP 65 front panel is also suitable for applications and installations where splashing water is present such as sanitary<br />
plants.<br />
■ Remote I/O Type 71VR1-E001 ■ DC Input Type 71VR1-E101 ■ Universal Input Type 71VR1-E501<br />
Do x 2<br />
Di x 2<br />
Modbus RS-485<br />
Do x 2<br />
Di x 2<br />
Modbus RS-485<br />
Do x 2<br />
Di x 2<br />
Modbus RS-485<br />
Remote I/O<br />
DC V/mA<br />
input x 2<br />
Remote I/O<br />
Universal input x 3<br />
(DC, TC and RTD)<br />
Remote I/O<br />
Analog sensor<br />
input x 8<br />
Discrete<br />
input x 6<br />
Discrete<br />
output x 6<br />
Analog sensor input x 6<br />
Discrete input x 6<br />
Discrete output x 6<br />
DC V/mA<br />
input x 2<br />
Analog sensor input x 3<br />
Discrete input x 6<br />
Discrete output x 6<br />
442<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
PC Recorder<br />
Log, Trend, Analyze and Profile Process<br />
Signals with your PC<br />
Field I/O connects directly to the PC Recorder Series, ideal for<br />
laboratory testing, monitoring and logging machine performance,<br />
heat-treating temperature monitoring, and quality control validation.<br />
ISP ’12<br />
443
444H<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
PC Recorder Series<br />
Remote data acquisition hardware and software<br />
◆◆<br />
Log, trend, analyze and profile process signals with<br />
your PC<br />
◆◆<br />
Data collected by PC Recorder Software:<br />
PC Recorder Light, MSR128 and MSRpro<br />
◆◆<br />
Modbus RTU or Modbus TCP/IP (Ethernet) network<br />
◆◆<br />
Full featured PC Recorder Software MSR128 for<br />
monitoring up to 128 channels simultaneously<br />
◆◆<br />
High speed sampling 50 ms / 8 ch with the basic<br />
software PC Recorder Light<br />
◆◆<br />
Client/Server <strong>System</strong> MSRpro for monitoring up to<br />
2048 channels<br />
◆◆<br />
Complete lines of M-<strong>System</strong>’s remote I/O products are<br />
available to accept a wide variety of field signals<br />
M-<strong>System</strong>’s PC Recorder Series provides a low cost industrial grade data acquisition system using free combinations of remote I/O<br />
hardware and monitoring/recording software.<br />
PC Recorder Series<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
MSRpro<br />
PC Recorder Hardware<br />
I/O Modules<br />
PC Recorder<br />
Field I/Os connect directly to the remote I/O modules and data is transmitted via Modbus RTU protocol over an RS-485 network.<br />
Ethernet network, Modbus TCP/IP protocol, is also usable either directly by Ethernet I/O modules or via a protocol converter by Modbus<br />
RTU I/O modules.<br />
Complete M-<strong>System</strong>’s remote I/O lines including R1, R3, R5, R6, R7 Series, are available for PC Recorder applications. They can handle<br />
not only temperature, millivolt/voltage/current or discrete signals, but also other field sensors such as strain gauge and pulse generating<br />
pickups. Furthermore, a wide variety of power measuring modules for AC voltage/current, watt/var and energy inputs are ideal to<br />
monitor and analyze energy consumption trends in detail by production line to build up a new energy saving scheme.<br />
The R1M, R2M and RZMS/RZUS modules are shipped with the free MSRPAC software package which includes the MSR128 and the PC<br />
Recorder Light. These economical modules are ideal for small scale temperature scanning applications such for silos, furnaces, ovens<br />
in many industrial fields, greenhouses, hydroponics plants, machine test benches and weather monitors. By using the universal input<br />
module RZMS/RZUS, other types of sensors signals, e.g. vibration, can be monitored together for failure analysis applications.<br />
Application Examples<br />
Engine Performance Testing Data Logging for Energy Management Furnace Temperature Monitoring<br />
Temperature<br />
drop rise<br />
R1M<br />
R1M<br />
PC<br />
R1M<br />
R1M<br />
Silo Temperature Regulation<br />
Temperature<br />
Temperature<br />
drop rise<br />
drop rise<br />
R1MS<br />
1500V<br />
Isolation<br />
PC<br />
R1M<br />
PC<br />
USB<br />
Furnace<br />
Silo<br />
RZUS-U9<br />
Engine<br />
Motor<br />
Note PC<br />
444<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Log, Trend, Analyze and Profile Process Signals with Your PC<br />
n MSRPAC<br />
PC Recorder Light<br />
MSR128LS / MSR128LV<br />
◆◆<br />
Ideal for basic logging and trending purposes.<br />
P.446<br />
◆◆<br />
Maximum sampling rate of 50 ms for 8 channels,<br />
500 ms to 1 minute for the total of 120 channels.<br />
PC Recorder Series<br />
H445<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Full Featured PC Recorder Software<br />
MSR128<br />
P.446<br />
◆◆<br />
Ideal for logging, trending and analyzing continuous<br />
process and batch applications.<br />
◆◆<br />
Up to 128 channels can be monitored simultaneously.<br />
◆◆<br />
Maximum sampling rate of 500 ms for 128 channels.<br />
◆◆<br />
High speed sampling 100 ms with R3 series TCP/IP<br />
module.<br />
PC Recorder Series<br />
PC Recorder<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
MSRpro<br />
PC Recorder Hardware<br />
I/O Modules<br />
n MSRpro (MSR2K)<br />
Client / Server <strong>System</strong><br />
High Performance PC Recorder<br />
◆◆<br />
Max. 2048 points.<br />
◆◆<br />
High speed 100 msec. mode up to 256 points.<br />
◆◆<br />
Active trend view to compare in real time past and<br />
present data overlapped on each other.<br />
◆◆<br />
Arithmetic and logic functions, including the ones<br />
performed between channels.<br />
◆◆<br />
Alarm history and data search functions.<br />
P.448<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
445
H<br />
446<br />
PC Recorder Software<br />
MSRPAC<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Remote data acquisition hardware and software<br />
MSRPAC PC Recorder Software Package<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
MSR128LS / MSR128LV – PC Recorder Light<br />
◆◆<br />
Ideal for basic logging and trending purposes<br />
◆◆<br />
Maximum sampling rate of 50 ms for 8 channels,<br />
500 ms to 1 minute for the total of 120 channels<br />
The MSR128-Light is designed to operate on a PC of relatively low<br />
performance, though certain functions of the MSR128 which require<br />
the PC’s high performance, are not available.<br />
The data used for the recorder is saved in CSV format allowing easy<br />
export to other Windows programs such as Microsoft Excel.<br />
Two models are available to run on low resolution screens.<br />
• MSR128LV for VGA (Screen area: 640 x 480 pixels)<br />
• MSR128LS for SVGA (Screen area: 800 x 600 pixels)<br />
MSR128 – Full Featured PC Recorder Software<br />
◆◆<br />
Ideal for logging, trending and analyzing continuous process<br />
and batch applications<br />
PC Recorder Series<br />
◆◆<br />
Up to 128 channels can be monitored simultaneously<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
MSRpro<br />
PC Recorder Hardware<br />
I/O Modules<br />
PC Recorder<br />
◆◆<br />
Maximum sampling rate of 500 ms for 128 channels<br />
◆◆<br />
High speed sampling 100 ms with R3 series TCP/IP module<br />
The MSR128 works with all PC Recorder modules. The MSR128<br />
software polls data from the input module, plots the value on the<br />
screen and stores it to the PC’s hard drive.<br />
The data is polled, plotted and stored at a maximum rate of 500 ms<br />
for 128 channels. Historical trends can be recalled, edited and used<br />
to be printed as hard copies or to be exported to spreadsheets for<br />
further analysis.<br />
Data can be exported in CSV format to popular spreadsheet software<br />
packages such as Microsoft Excel.<br />
Data can be directly imported allowing the user to take full advantage<br />
of spreadsheet software features.<br />
446<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
PC Recorder Software MSRPAC<br />
H<br />
447<br />
Signal Conditioners<br />
SYSTEM CONFIGURATION EXAMPLES<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Minimum Configuration<br />
MSRPAC<br />
PC Recorder Software<br />
Expanded <strong>System</strong> via Modbus RTU<br />
MSRPAC<br />
PC Recorder Software<br />
Expanded <strong>System</strong> via Ethernet<br />
MSRPAC<br />
PC Recorder Software<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
RS-232C*<br />
RS-485 / Modbus RTU<br />
RS-232C*<br />
Ethernet<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
R1M, R1MS, R2M or RZMS Series R1M-D1 R1M-A1 R1M-GH2<br />
*USB port is usable by using an adaptor.<br />
R3 Series<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Expanded <strong>System</strong> via Modbus RTU (R7 + MSR)<br />
Expanded <strong>System</strong> via Ethernet (73VR + R7 + MSR)<br />
MSRPAC<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
Ethernet<br />
PC Recorder Series<br />
RS-232C/RS-485 Converter<br />
R2K-1<br />
RS-485<br />
Paperless Recorder Paperless Recorder<br />
73VR3100 73VR21xx<br />
Paperless Recorder<br />
73VR1100<br />
RS-485<br />
PC Recorder<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
MSRpro<br />
PC Recorder Hardware<br />
I/O Modules<br />
R7M Series<br />
R7M Series<br />
R7M Series<br />
R7M Series<br />
R7M Series<br />
Expanded <strong>System</strong> via Modbus RTU (53U + MSR)<br />
Expanded <strong>System</strong> via Ethernet (53U + MSR)<br />
MSRPAC<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
Ethernet<br />
RS-232C/RS-485 Converter<br />
R2K-1<br />
RS-485<br />
Communication Adaptor<br />
72EM2-M4<br />
RS-485<br />
Multi Power Monitor<br />
53U<br />
53U 53U Multi Power Monitor<br />
53U<br />
53U<br />
53U<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
447
H<br />
Signal Conditioners<br />
448<br />
PC Recorder Software<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
MSRpro Client/Server system high performance PC Recorder (Model: MSR2K)<br />
◆◆<br />
Max. 2048 points<br />
◆◆<br />
High speed 100 msec. mode up to 256 points<br />
◆◆<br />
Active trend view to compare in real time past and present data overlapped on each other<br />
◆◆<br />
Arithmetic and logic functions, including the ones performed between channels<br />
◆◆<br />
Alarm history and data search functions<br />
The MSRpro is a ‘paperless pen-type’ recording system for PC-based data acquisition and analysis. By communicating with I/O<br />
modules that have a LAN card communication interface, the MSRpro reads in input signals and stores them in a hard disk as digital<br />
data.<br />
By sharing viewing and storing tasks by ‘Client’ and ‘Server,’ the MSRpro realizes the recording and operating functions of large<br />
number of input signals in high speed.<br />
M-<strong>System</strong>’s remote I/O modules, R3 Series, offers a wide variety of input signals including DC and AC signals, temperature,<br />
potentiometer, strain gauge and others.<br />
The MSRpro is a suite of three programs:<br />
PC Recorder Series<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
MSRpro<br />
PC Recorder Hardware<br />
I/O Modules<br />
PC Recorder<br />
MSRpro-Server<br />
MSRpro-Client/Analyzer<br />
MSRpro-Builder<br />
Collects and stores input measurement data and<br />
executes arithmetic computation to it.<br />
Used to view, analyze and print<br />
measurement data.<br />
Creates and modifies configurations for either<br />
program.<br />
R3 Series I/O<br />
Analog Input<br />
Contact Input<br />
Contact Output<br />
MSRpro-Server<br />
Sample<br />
Store<br />
Compute<br />
Personal Computer<br />
Stored Data<br />
Trend View Overview Active Trend Graphic<br />
MSRpro-Client/<br />
Analyzer<br />
(Data Views)<br />
Trend Graph<br />
Overview<br />
Alarm History<br />
Trend Retrieval<br />
MAX.4 (Client PC)<br />
Server PC<br />
Client PC<br />
• MSRpro-Client/<br />
Analyzer<br />
• MSRpro-Server<br />
• MSRpro-Builder<br />
Modbus / TCP Ethernet<br />
Modbus RTU<br />
RS-485<br />
Communication<br />
Adaptor<br />
72EM2-M4<br />
R1M Series<br />
R7M Series<br />
RZMS-U9<br />
R3 Series R3 Series Paperless Recorder<br />
73VR3100<br />
Paperless Recorder<br />
73VR21xx<br />
R5 Series<br />
MAX.8 stations (incl.72EM2-M4)<br />
448<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
PC Recorder Software MSRpro<br />
H<br />
449<br />
Signal Conditioners<br />
SYSTEM CONFIGURATION EXAMPLES<br />
Expanded <strong>System</strong> via Ethernet (73VR + R7 + MSR)<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
• MSRpro-Client/Analyzer<br />
• MSRpro-Server<br />
• MSRpro-Builder<br />
Limit Alarms<br />
Ethernet<br />
Ethernet<br />
Hub/Switch<br />
RS-485<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
R3 Series<br />
R5 Series<br />
Paperless Recorder<br />
73VR3100<br />
Paperless Recorder<br />
73VR21xx<br />
Communication<br />
Adaptor<br />
72EM2-M4<br />
R7M Series R7M Series R7M Series<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Expanded <strong>System</strong> via Ethernet (53U + MSR)<br />
Ethernet<br />
• MSRpro-Client/Analyzer<br />
• MSRpro-Server<br />
• MSRpro-Builder<br />
PC Recorder Series<br />
Communication<br />
Adaptor<br />
72EM2-M4<br />
Multi Power Monitor<br />
53U<br />
53U<br />
RS-485<br />
53U<br />
PC Recorder<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
MSRpro<br />
PC Recorder Hardware<br />
I/O Modules<br />
Power Monitoring <strong>System</strong><br />
• MSRpro-Client/Analyzer<br />
Ethernet<br />
Ethernet<br />
• MSRpro-Server<br />
• MSRpro-Builder<br />
Communication<br />
Adaptor<br />
72EM2-M4<br />
RS-485<br />
Communication<br />
Adaptor<br />
72EM2-M4<br />
RS-485<br />
Multi Power Monitor<br />
53U<br />
53U<br />
R7M Series<br />
R7M Series<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
449
H<br />
Signal Conditioners<br />
450<br />
PC Recorder Hardware<br />
I/O Modules<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Complete M-<strong>System</strong>’s remote I/O lines are available for PC Recorder applications.<br />
Choose from a wide variety of simple all-in-one modules and flexible mixed signal modules depending on your needs.<br />
n I/O Modules Usable for MSRPAC<br />
◆ MSR128LS / MSR128LV PC Recorder Light<br />
Mixed signal I/O modules in free combinations<br />
of number and type<br />
The MSRPAC is not included.<br />
All-in-one I/O modules with the MSRPAC included<br />
in the product package<br />
The MSRPAC is included in the hardware product package.<br />
Economical solution for basic trending/recording applications.<br />
R3 Series R5 Series<br />
R2 Series R1M Series RZ Series<br />
◆ MSR128 Full Featured PC Recorder Software<br />
Mixed signal I/O modules in free combinations of number and type<br />
The MSRPAC is not included.<br />
R3 Series<br />
R5 Series<br />
R6 Series<br />
R7M Series<br />
53U<br />
PC Recorder Series<br />
All-in-one I/O modules with the MSRPAC included in the product package<br />
The MSRPAC is included in the hardware product package.<br />
Economical solution for basic trending/recording applications.<br />
Paperless Recorders with the MSR128<br />
included in the 73VRPAC2<br />
PC Recorder Software<br />
MSRPAC<br />
PC Recorder Software<br />
MSRpro<br />
PC Recorder Hardware<br />
I/O Modules<br />
PC Recorder<br />
R2 Series R1M Series RZ Series 73VR Series<br />
n I/O Modules Usable for MSRpro<br />
◆ MSRpro Client/Server <strong>System</strong> High Performance PC Recorder<br />
Modbus RTU modules connected via the 72EM2-M4<br />
All-in-one I/O modules<br />
R2 Series R1M Series RZ Series<br />
R7M Series<br />
53U<br />
Direct Ethernet connection<br />
Mixed signal I/O modules<br />
Paperless Recorders with the MSR128<br />
included in the 73VRPAC2<br />
R3 Series<br />
R5 Series<br />
73VR21xx, 73VR3100<br />
n Protocol Converters<br />
Ethernet Communication Adaptor (Modbus use)<br />
model : 72EM2-M4<br />
RS-232C / RS-485 Converter<br />
model : R2K-1<br />
450<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Electric Actuators<br />
& Position Sensors<br />
High resolution positioning for superior<br />
valve control<br />
Rotary and linear actuators for valve and flow control feature long life with<br />
brushless stepping motors, variable opening/closing speeds and builtin<br />
overload protection. Also, offered is a line of complementary position<br />
sensors for closed-loop verification of valve position.<br />
ISP ’12<br />
451
452 i<br />
Signal Conditioners<br />
Electric Actuators<br />
Two-wire<br />
Signal Conditioners<br />
n Linear motion type<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
Linear Electric Actuators<br />
MSP Series for thrust 700–2500 N<br />
Brushless stepping motor<br />
Enhances the durability and reliability<br />
of M-<strong>System</strong>’s electric actuators.<br />
FEATURES<br />
◆◆<br />
High resolution positioning for better valve control<br />
◆◆<br />
Built-in feedback positioner and electric limiter<br />
◆◆<br />
Brushless stepping motor assures long-life operation<br />
◆◆<br />
1/1000 resolution<br />
◆◆<br />
Optional interface with CC-Link or DeviceNet<br />
APPLICATIONS<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Unaffected by pressure fluctuations<br />
from the process<br />
Line pressure fluctuations are absorbed<br />
by the screw shaft.<br />
Sealing spring mechanism<br />
Built-in sealing spring retains the sealing<br />
pressure at the closed position.<br />
MSP5<br />
◆◆<br />
Pilot plants<br />
◆◆<br />
Fuel valve control<br />
◆◆<br />
Tank valve control in brending machines<br />
◆◆<br />
HVAC damper positioning<br />
◆◆<br />
Pharmaceutical, wastewater flow controls<br />
◆◆<br />
Pulp & paper: paper profiling control<br />
MSP Series<br />
Electric Actuators<br />
Position Sensors<br />
Valve Positioners<br />
Control Backups<br />
Model MSP4 MSP5 MSP6<br />
Model (DeviceNet) MSP4D MSP5D MSP6D<br />
Model (CC-Link) MSP4C MSP5C MSP6C<br />
Max. Stroke 15 mm (0.59”) 20 mm (0.79”) 40 mm (1.57”)<br />
Max. Thrust 700 N (157 lbs) 700 N (157 lbs) 2500 N (562 lbs)<br />
MSP4, MSP4C MSP4D MSP5, MSP5C MSP5D MSP6, MSP6C MSP6D<br />
Operation Time<br />
(10 mm)<br />
5 sec. / 150N<br />
9 sec. / 300N<br />
18 sec. / 700N<br />
24 sec. / 500N<br />
30 sec. / 700N<br />
5 sec. / 150N<br />
9 sec. / 300N<br />
18 sec. / 700N<br />
12 sec. / 300N<br />
24 sec. / 500N<br />
30 sec. / 700N<br />
5 sec. / 600N<br />
8 sec. / 1200N<br />
15 sec. / 2500N<br />
Resolution 1/1000 or 0.015 mm 1/1000 or 0.02 mm<br />
Input Signal<br />
4–20mA or 1–5V DC (DeviceNet for MSPxD, CC-Link for MSPxC)<br />
Position Output<br />
1–5V DC (DeviceNet for MSPxD, CC-Link for MSPxC)<br />
Motor<br />
Stepping motor<br />
Position Detection<br />
Potentiometer<br />
Power Input<br />
24V DC, 100–120V AC* 1 , 200–240V AC* 1 (24V DC for MSPxD and MSPxC)<br />
Degree of Protection IP 55<br />
9 sec. / 600N<br />
18 sec. / 1200N<br />
24 sec. / 1800N<br />
36 sec. / 2500N<br />
42 43 22 (.87) CABLE CONNECTOR<br />
(1.65) (1.69) w/1 meter (3.28 ft) LEADWIRE<br />
42 43<br />
(1.65) (1.69)<br />
22 (.87) CABLE CONNECTOR<br />
w/1 meter (3.28 ft) LEADWIRE<br />
CABLE CONNECTOR<br />
w/1 meter (3.28 ft) LEADWIRE<br />
146 (5.75) 22 (.87)<br />
98 (3.86)<br />
98 (3.86)<br />
110 (4.33)<br />
20<br />
(.79)<br />
External<br />
Dimensions* 2<br />
[mm(inch)]<br />
0<br />
36 – 0.1 dia.<br />
90 (3.54)<br />
[130 (5.12)]<br />
34* 141 (5.55) [181 (7.13)]<br />
(1.34) max.<br />
YOKE SURFACE<br />
*29 (1.14) max. with 5 – 10 mm stroke<br />
[ ] for AC power supply<br />
0<br />
36 – 0.1 dia.<br />
90 (3.54)<br />
[130 (5.12)]<br />
141 (5.55) [181 (7.13)]<br />
50*<br />
(1.97) max.<br />
YOKE SURFACE<br />
*40 (1.57) max. with 5 – 10 mm stroke<br />
[ ] for AC power supply<br />
36 (1.42) dia.<br />
YOKE<br />
SURFACE<br />
62 (2.44) 136 (5.35)<br />
78* 218 (8.58)<br />
(3.07) max.<br />
*58 (2.28) max. with 10 – 20 mm stroke<br />
452<br />
*<br />
1. Not selectable for CE<br />
2. Please refer to the data sheets for external views of MSPxD and MSPxC.<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Electric Actuators<br />
i 453<br />
Signal Conditioners<br />
Failsafe Linear Electric Actuators<br />
PSN Series for thrust 3000–5000 N<br />
CSP Series for thrust 12000 N<br />
PSN1<br />
PSN Series<br />
Manual Operation<br />
Available<br />
FEATURES<br />
PSN Series<br />
◆◆<br />
Brushless position sensor eliminates problems with<br />
mechanical potentiometer feedback sensing<br />
◆◆<br />
Opening/closing speed, split range and failsafe position<br />
programmable by hand-held programmer<br />
◆◆<br />
Internal temperature sensor to control heater in cold<br />
climate and to prevent motor from overheating<br />
◆◆<br />
Forced-open/-closed contacts for remote or manual override<br />
CSP Series<br />
◆◆<br />
Suitable for high thrust/long stroke applications<br />
APPLICATIONS<br />
◆◆<br />
Chemical injection/mixing<br />
◆◆<br />
Fuel valve control<br />
◆◆<br />
Pharmaceutical flow controls<br />
◆◆<br />
Wastewater flow control<br />
◆◆<br />
HVAC damper positioning<br />
◆◆<br />
Food machines<br />
CSP Series<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Electric Actuators<br />
Model PSN1 PSN3 CSP<br />
Max. Stroke 40 mm (1.57”) 60 mm (2.36”) 75 mm (2.95”)<br />
Max. Thrust 3000 N (674 lbs) 5000 N (1124 lbs) 12000 N (2697 lbs)<br />
Operation Time 0.30–5.65 mm/s * 3 0.22–4.02 mm/s * 3 34 sec. / 20 mm<br />
Resolution 0.04 mm 0.06 mm Hysteresis 1 mm or less<br />
Input Signal<br />
4–20mA or 1–5V DC<br />
Position Output<br />
4–20mA DC<br />
Motor Stepping motor AC motor<br />
Position Detection Brushless angle sensor Potentiometer<br />
Power Input 24V DC, 100–120V AC* 4 , 200–240V AC 100V AC, 110V AC, 200V AC, 220V AC<br />
Degree of Protection IP 55 IP 56<br />
Failsafe Function Optional ----<br />
Position Sensors<br />
Valve Positioners<br />
Control Backups<br />
External Dimensions<br />
[mm(inch)]<br />
MANUAL<br />
OPERATION<br />
STEM,<br />
8 (.31) sq.<br />
182 (7.17)<br />
101 (3.98) 81 (3.19)<br />
0 (2.37)<br />
ø60–0.1 (2.35)<br />
140 (5.51)<br />
10 (.39)<br />
99.5 (3.92) 122 (4.80)<br />
221.5 (8.72)<br />
10.5 (.41)<br />
66 – 106<br />
(2.60 – 4.17)<br />
YOKE SURFACE<br />
MANUAL<br />
OPERATION<br />
STEM,<br />
8 (.31) sq.<br />
200 (7.87)<br />
110 (4.33) 90 (3.54)<br />
ø70h8<br />
12 (.47) 150 (5.91)<br />
118.5 (4.66) 130 (5.12)<br />
248.5 (9.78)<br />
10.5 (.41)<br />
66 – 126<br />
(2.60 – 4.96)<br />
YOKE SURFACE<br />
11 (.43)<br />
2.5 (.10)<br />
ø216 (8.50)<br />
79 40<br />
(3.11) (1.57)<br />
65 65<br />
(2.56) (2.56)<br />
177 (6.97) 103 (4.06)<br />
280 (11.02)<br />
12<br />
(.47)<br />
Handle knob position at use<br />
71<br />
(2.80)<br />
69<br />
(2.72)<br />
30 (1.18)<br />
196 (7.72)<br />
336 (13.23)<br />
140 (5.51)<br />
35 (1.38)<br />
ISP ’12<br />
*<br />
3. Thrust depends on the opening / closing speed. Please refer to the data sheets for detailed specifications.<br />
4. Not selectable for CE<br />
Specifications are subject to change without notice.<br />
453
i<br />
454 Electric Actuators<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
n Rotary motion type<br />
Rotary Electric Actuators<br />
MRP Series for torque 5–33 N·m<br />
MRM6 for torque 40 N·m<br />
MRP4<br />
FEATURES<br />
MRP Series<br />
◆◆<br />
High resolution positioning for better valve control<br />
◆◆<br />
Built-in feedback positioner and electric limiter<br />
◆◆<br />
Brushless stepping motor assures long-life operation<br />
◆◆<br />
1/1000 resolution<br />
MRM6<br />
◆◆<br />
Small-size electric actuator for inching control<br />
APPLICATIONS<br />
MRP Series<br />
◆◆<br />
Pilot plants<br />
◆◆<br />
Chemical injection/mixing<br />
◆◆<br />
HVAC damper positioning<br />
◆◆<br />
Food machines<br />
◆◆<br />
Pharmaceutical, wastewater flow controls<br />
MRM6<br />
◆◆<br />
Vane motors for compressor<br />
MRP Series<br />
MRM6<br />
Electric Actuators<br />
Position Sensors<br />
Valve Positioners<br />
Control Backups<br />
Model MRP4 MRP5 MRP6 MRM6<br />
Model (DeviceNet) MRP4D MRP5D MRP6D –<br />
Model (CC-Link) MRP4C MRP5C MRP6C –<br />
Max. Angle 90°, 180° 90° 90°, 180° 302°<br />
Max. Torque 5 N·m (3.69 ft·lbs) 10 N·m (7.38 ft·lbs) 33 N·m (24.3 ft·lbs) 40 N·m (29.5 ft·lbs)<br />
Operation Time<br />
7, 13 sec. / 90° (MRP4, MRP4C) 13 sec. / 90° (MRP5, MRP5C) 4, 7, 13 sec. / 90° (MRP6, MRP6C)<br />
12 sec. / 90° (MRP4D) 22 sec. / 90° (MRP5D) 7, 14, 18, 27 sec. / 90° (MRP6D)<br />
290 sec.<br />
Resolution 1/1000 or 0.09° ----<br />
Input Signal 4–20mA or 1–5V DC (DeviceNet for MRPxD, CC-Link for MRPxC) Inching control<br />
Position Output 1–5V DC (DeviceNet for MRPxD, CC-Link for MRPxC) 10kΩ<br />
Motor<br />
Stepping motor<br />
Position Detection<br />
Potentiometer<br />
Power Input 24V DC, 100–120V AC* 1 , 200–240V AC* 1 (24V DC for MRPxD and MRPxC) 100–120V AC, 200–240V AC<br />
Degree of Protection IP 55<br />
External<br />
Dimensions* 2<br />
[mm(inch)]<br />
CABLE CONNECTOR<br />
w/1 meter (3.28 ft) LEADWIRE<br />
99 (3.90)<br />
23 (.91)<br />
22 (.87)<br />
90 (3.54)<br />
[130 (5.12)]<br />
98 (3.86)<br />
127 (5) [167 (6.57)]<br />
17<br />
(.67)<br />
12 (.47) dia. YOKE SURFACE<br />
[ ] for AC power supply<br />
CABLE CONNECTOR<br />
w/1 meter (3.28 ft) LEADWIRE<br />
7 (.28)<br />
12 (.47) dia.<br />
99<br />
(3.90)<br />
22<br />
(.87)<br />
90 (3.54)<br />
[130 (5.12)]<br />
YOKE<br />
SURFACE<br />
98 (3.86)<br />
166 (6.54) [206 (8.11)]<br />
[ ] for AC power supply<br />
17<br />
(.67)<br />
110 (4.33)<br />
199 (7.83)<br />
136 (5.35)<br />
16 (.63)<br />
CABLE CONNECTOR<br />
w/1 meter (3.28 ft) LEADWIRE<br />
146 (5.75) 23 (.87)<br />
16 (.63) dia.<br />
YOKE SURFACE<br />
22 (.87)<br />
16 (.63)<br />
182 (7.17)<br />
110 (4.33)<br />
111 (4.37)<br />
145 (5.71) [48 (1.89)]<br />
51 (2.01) 144 (5.67)<br />
12 (.47) dia. 2–G1/2<br />
454<br />
* 1. Not selectable for CE 2. Please refer to the data sheets for external views of MRPxD and MRPxC.<br />
*<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
High Torque Rotary Electric Actuators<br />
PRP Series for torque 100–200 N·m<br />
CRP Series for torque 68.6–588 N·m<br />
Worm gear Worm wheel Conductive<br />
plastic<br />
Position indicator<br />
potentiometer<br />
PRP<br />
Failsafe internal<br />
battery backup<br />
Microprocessor<br />
based control circuitry<br />
Modular jack<br />
Manual Operation<br />
Available<br />
Brushless<br />
stepping motor<br />
Ball bearing and<br />
reduction gear<br />
Manual operation stem<br />
FEATURES<br />
Electric Actuators<br />
PRP Series<br />
◆◆<br />
Brushless high-resolution DC stepping motor<br />
assures long-life operation<br />
◆◆<br />
Opening/closing speed, split range and failsafe<br />
position programmable by hand-held programmer<br />
◆◆<br />
Temperature sensor helps to reduce overall<br />
power consumption by activating heating function<br />
only in low temperature<br />
◆◆<br />
1/1000 resolution<br />
CRP Series<br />
◆◆<br />
Simple field adjustments<br />
◆◆<br />
Electric limiters for full-open/closed positions<br />
APPLICATIONS<br />
◆◆<br />
Paper mill<br />
◆◆<br />
HVAC damper positioning<br />
◆◆<br />
Fuel and gas exhaust valve controls<br />
◆◆<br />
Onboard engine coolant line control<br />
◆◆<br />
Co-generation plant<br />
i 455<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
PRP Series<br />
CRP Series<br />
Model PRP-0 PRP-1 CRP-0 CRP-1 CRP-2<br />
Max. Angle 90°<br />
Max. Torque 100 N·m (73.7 ft·lbs) 200 N·m (147.5 ft·lbs) 68.6 N·m (50.6 ft·lbs) 196 N·m (144.7 ft·lbs) 588 N·m (434.0 ft·lbs)<br />
Operation Time 8.5–125 sec. / 90° 16–125 sec. / 90° 12, 24 sec. / 90° 12, 24 sec. / 90° 18, 36 sec. / 90°<br />
Resolution 1/1000 0.45°, 0.68°, 0.90°<br />
Input Signal<br />
4–20mA or 1–5V DC<br />
Position Output<br />
4–20mA DC<br />
Motor Stepping motor AC motor<br />
Position Detection<br />
Potentiometer<br />
Power Input 100–120V AC, 200–240V AC 100V AC, 110V AC, 200V AC, 220V AC<br />
Degree of Protection IP 66 IP 55<br />
Failsafe Function Optional ----<br />
Electric Actuators<br />
Position Sensors<br />
Valve Positioners<br />
Control Backups<br />
2-G1/2 CONDUIT 107 (4.21)<br />
177 (6.97)<br />
77 (3.03)<br />
100 (3.94) 70 (2.76)<br />
96 (3.78) 58 (2.28)<br />
POSITION INDICATOR<br />
n CRP-2<br />
2–G 1/2 CONDUIT<br />
85 (3.35)<br />
133 (5.24)<br />
120 (4.72)<br />
External Dimensions<br />
[mm(inch)]<br />
159 (6.26)<br />
149 (5.87)<br />
61<br />
(2.40)<br />
MANUAL OPERATION<br />
(hexagonal 6mm)<br />
313 (12.32)<br />
[171 (6.73)] 142 (5.59)<br />
50.1<br />
(1.97)<br />
40 (1.57) 154 (6.06)<br />
17 (.67)<br />
202 (7.95) 164 (6.46)<br />
MANUAL OPERATION<br />
(hexagonal 6 mm)<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
455
i<br />
456 Position Sensors /<br />
Signal Conditioners Valve Positioners / Control Backups<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
n Position Sensors<br />
M-<strong>System</strong>’s Model VOS2T and VOS2T-R are two-wire position<br />
transmitters incorporating a brushless angle sensor as their key<br />
sensing component. They detect rotating angles of pneumatic and<br />
electric actuators and send 4 to 20mA DC signal proportional to<br />
the angles.<br />
They are also widely used in monitoring and automating various<br />
mechanical systems.<br />
FEATURES APPLICATIONS<br />
VOS2T<br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
◆◆<br />
Lightweight & compact design<br />
◆◆<br />
High resolution<br />
◆◆<br />
Direct and reverse actions are selectable in field<br />
◆◆<br />
IP 66 diecast aluminum enclosure is suitable for<br />
field applications<br />
◆◆<br />
Position transmitter for pneumatic control valve or dampers<br />
◆◆<br />
Proportional control of an ON/OFF valve<br />
◆◆<br />
Position feedback for motor-driven systems or servo<br />
control systems<br />
◆◆<br />
Measuring roller position displacement in paper,<br />
cloth and other types of film feeders<br />
◆◆<br />
Upward/downward positioning for boarding bridges<br />
◆◆<br />
Rudder direction sensing<br />
◆◆<br />
Liquid level sensing in reservoir tanks<br />
PRODUCTS & SPECIFICATIONS<br />
Electric Actuators<br />
Position Sensors<br />
Valve Positioners<br />
Control Backups<br />
Linear Motion Type Rotary Motion Type<br />
Model VOS2T VOS2T-R<br />
Linearity Assured Range -22.5 to +22.5° -45 to +45°<br />
Effective Rotating Angle approx. -27 to +27° approx. -55 to +55°<br />
Stopper Strength 1.37 N·m (1.011 ft·lbs) with static load<br />
Output Action<br />
Direct or Reverse<br />
Output Signal<br />
4–20mA DC<br />
Load Resistance<br />
0–600 Ω with 24V DC supply<br />
Supply Voltage<br />
15–28V DC<br />
Degree of Protection IP 66<br />
Wiring Conduit G 1/2<br />
Operating Temperature<br />
-5 to +60°C (23 to 140°F)<br />
Maximum Vibration<br />
2 G<br />
Approx. Weight 550 g (1.21 lbs) without lever and cable<br />
Linearity<br />
1.0% within the linearity assured range<br />
Diecast aluminum enclosure<br />
Direct/Reverse selector<br />
Terminal block<br />
Lever<br />
Indicator<br />
Direct drive shaft<br />
Brushless angle sensor<br />
Cable gland<br />
• Explosion-proof type available (Model: VOS-E, VOS-ER).<br />
n Valve Positioners & Control Backups<br />
Valve Positioners<br />
MEX Series<br />
Motor position/controller<br />
◆◆Plug-in construction<br />
◆◆DIN rail/surface mount<br />
◆◆4–20mA DC or potentiometer position feedback<br />
◆◆SSR or AC switch control output<br />
◆◆Analog re-transmission<br />
MEX-F<br />
Control Backups<br />
ABF Series<br />
Control backup/manual loading station<br />
◆◆Holds and manipulates control signals in case of<br />
computer or DCS failure<br />
◆◆Bargraph indicator<br />
◆◆Digital display indicating PV/<br />
CAS/MV selectable<br />
◆◆External contact closure to<br />
switch operation modes<br />
ABF3<br />
456<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors<br />
Protecting sensor, signal, power and<br />
communication lines<br />
Designed for the rugged industrial environment. Products range from<br />
the standard factory floor signals such as 4 – 20mA, thermocouple,<br />
RTD and strain gauge to filtering and protecting the AC Power<br />
and communication lines in instrument panels.<br />
ISP ’12<br />
457
J<br />
458 Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
What is Lightning How to Protect Instruments<br />
Entry pathway of lightning surge<br />
Due to the online application of modern electronic systems, there are multiple interfacing parts to the outside for an instrument.<br />
One of such interface parts is signal cable and the other one is power cable. These cables pulled from the outside can<br />
be perfect entry pathways for the lightning surge.<br />
The effects of induced surge on a connected device will be<br />
more severe when the connected cable is longer and the<br />
device is located closer to the place where the actual lightning<br />
strikes. Even lightning rods with minimal cable length do not<br />
always protect as they are hoped.<br />
The effect of lightning surges depends upon the cable location<br />
and its environment. Surge protectors installed in those<br />
paths absorb and eliminate the high voltage impulse energy<br />
and protect the electric instrument from damage (Figure 1).<br />
Figure 1<br />
signal<br />
line<br />
surge<br />
protector<br />
G<br />
ground<br />
system<br />
G<br />
G<br />
power<br />
line<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Lightning Surge Protectors<br />
Breaking mode of electrical instrument<br />
Surge voltage generated between a cable and the ground might reach several tens of thousands of volt, however, lightning<br />
occurs at a voltage typically five thousand volts between the cable and the ground, while it induces several hundred volts<br />
between lines.<br />
When analyzing breaking condition of the instrument, it is often broken by this line voltage. We call it ‘interline breakdown’.<br />
Characteristics of interline breakdown is that semiconductor parts near the entry point of lightning surge breaks.<br />
Also, breaking mode between the cable and the ground is called ‘discharge breakdown’. Because the lightning surge voltage<br />
is very high against that of the ground, an arc discharge is generated between an electronic circuit and a grounded enclosure.<br />
Characteristics of discharge breakdown is that weak part of insulation between the circuit and enclosure breaks down.<br />
M-<strong>System</strong>’s surge protectors keep the surge voltage level at which instrument does not get damaged and prevent interline<br />
breakdown and discharge breakdown.<br />
Interline breakdown (V1)<br />
This occurs when the surge voltage between cables is directly applied to the electronic components in the instrument.<br />
Usually, only these components that are located near the termination of the cable where the surge entered are destroyed.<br />
Discharge breakdown (V2, V3)<br />
Lightning surges cause a very high potential (voltage) difference between<br />
two conductors and the ground, and a discharge occurs between<br />
some part of an electronic circuit and those electrically connected to<br />
the ground, such as metal housings. Electronic components become<br />
damaged because some of the discharge current flows through the<br />
electronic circuit (Figure 2).<br />
lightning surge<br />
cable<br />
V3<br />
V1<br />
V2<br />
+<br />
–<br />
instrument<br />
G<br />
Figure 2<br />
ground<br />
458<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
459<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Fundamentals of surge absorbing<br />
Induced lightning is a current source which tries to flow the current. This current is the lightning surge current. When<br />
current does not flow smoothly, it generates high voltage and forces to let the current flow. The high voltage generated at<br />
that time is lightning surge voltage.<br />
Now, let us explain the fundamentals of lightning surge protector. Here we explain them with an example of a most commonly<br />
used model, the MDP-24-1. The diagram below is a simplified circuit of the MDP-24-1. On the cable, lightning surge voltage<br />
V 1 -V 3 is generated to let the current flow. We call V 1 , interline surge voltage, and V 2 and V 3 , line to ground surge voltage.<br />
The surge protector absorbs V 1 at the discharge element SA1 and V 2 and V 3 in SA2 and SA3. SA1-SA3 can be considered<br />
as voltage-dependant switches. When the voltage is high, an arc is discharged and they suppress the arc discharge of V 1 -<br />
V 3 around 30V. It is important to limit the surge voltage as low as possible. Especially, V 1 , which is applied directly to the<br />
protected instrument, is eliminated by the discharge element SA1 and the voltage limiting element D1.<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
SA can bypass high current, however, its firing potential is high and the setting voltage varies widely. In order to compensate<br />
these disadvantages, it is combined with D1 of which firing potential is low and the setting voltage does not vary much and<br />
suppresses the surge voltage to a low level. D1, which does not tolerate high current, is also protected by R1 which limits the<br />
surge current (Figure 3).<br />
The discharge element and the voltage<br />
limiting element together are called the<br />
surge absorber element. Since there is no<br />
one ideal surge absorber element, i.e. small<br />
size, small setting voltage variation, fast<br />
response time, high discharge withstand<br />
current rating, no failure in shortcircuit<br />
mode, the surge absorber circuit is designed<br />
with combinations of components to bring<br />
out their good characteristics.<br />
Which surge protector do you choose<br />
Surge protectors for signal line<br />
surge<br />
Figure 3<br />
cable resistance<br />
M-<strong>System</strong>’s surge protectors are classified according to sensor/signal types, such as standard 4–20 mA signal, RTD, thermocouple,<br />
potentiometer, strain gauge and pulse generating device. We also have those specific for various field networks<br />
such as RS-485/RS-422, Ethernet, DeviceNet, PROFIBUS, LONWORKS and FOUNDATION Fieldbus.<br />
V1<br />
V3<br />
S<br />
SA1<br />
S<br />
V2 SA2 SA3<br />
G<br />
ground<br />
R1<br />
D1<br />
P<br />
P<br />
+<br />
–<br />
protected<br />
device<br />
electric<br />
circuitry<br />
G<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Lightning Surge Protectors<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
[Example]<br />
A two-wire transmitter in general transmits 4 to 20mA DC output signal, powered by 24V DC power source on the same loop.<br />
Choose the lightning surge protector for standard signal (ex. MDP-24-1). Both transmitter and control room instrument<br />
incorporate electric circuits. Therefore, surge protectors are needed at the both side.<br />
In case of RTD, choose the lightning surge protector for RTD use (ex. MDP-RB). Even though the sensor has no electric<br />
circuit, a surge protector should be connected at the detection side in order to prevent the platinum resistance probe from<br />
breaking, in addition to the transmitter side.<br />
Surge protectors for power line<br />
Maximum load current up to 200 A is selectable. Single-phase/two-wire, single-phase/three-wire, three-phase/three-wire<br />
and DC power supply systems are selectable. Choose one based on the load current and the number of phase.<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
459
460J<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Lightning Surge Protectors<br />
for Electronics Equipment<br />
M-RESTER<br />
M-<strong>System</strong> Lightning Surge Protectors absorb only the lightning surges with no interruption<br />
of the instrumentation signal.<br />
◆◆<br />
Protects sensor, signal and power lines<br />
◆◆<br />
Can be removed and tested without disconnecting<br />
wires (MDP series)<br />
◆◆<br />
Superior protection and selection across a wide range<br />
of applications including:<br />
4–20mA & pulse signal<br />
Thermocouple<br />
RTD<br />
Potentiometer<br />
Strain gauge<br />
Frequency generating devices<br />
Telemetering devices<br />
RS-485 / RS-422, Ethernet, DeviceNet,<br />
PROFIBUS, LONWORKS, FOUNDATION Fieldbus<br />
AC/DC Power supply lines (1 amp up to 30 amps)<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
■■Standard Signal Line & Pulse Use<br />
Model Function Page<br />
■■Sensor Use<br />
Model Function Page<br />
MD7AST<br />
Lightning Surge Protector for Standard Signal<br />
Line (ultra-slim; life monitor)<br />
P.462<br />
MD7TC<br />
Lightning Surge Protector for Thermocouple<br />
(ultra-slim)<br />
P.465<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Lightning Surge Protectors<br />
MDPA-24<br />
MDPA-65<br />
MDM2A-24<br />
MDM2A-65<br />
MD7ST<br />
MDP-24-1<br />
MDP-65-1<br />
MDK-24<br />
MDJST<br />
MMDH<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (life monitor)<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (life monitor)<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (life monitor)<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (life monitor)<br />
Lightning Surge Protector for Standard Signal<br />
Line (ultra-slim)<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use<br />
Lightning Surge Protector for Standard Signal<br />
Line Use<br />
Lightning Surge Protector for Standard Signal<br />
Use (fast response: 3 nsec.)<br />
Lightning Surge Protector for Standard Signal<br />
Line Use<br />
(high speed/high discharge current capacity)<br />
P.462<br />
P.462<br />
P.462<br />
P.462<br />
P.462<br />
P.462<br />
P.462<br />
P.463<br />
P.463<br />
P.463<br />
MDP-TC Lightning Surge Protector for Thermocouple Use P.465<br />
MD7RB Lightning Surge Protector for RTD (ultra-slim) P.465<br />
MDP-RB Lightning Surge Protector for RTD Use P.465<br />
MD7PM<br />
Lightning Surge Protector for Potentiometer<br />
(ultra-slim)<br />
P.465<br />
MDP-PM Lightning Surge Protector for Potentiometer Use P.465<br />
MD7LC<br />
Lightning Surge Protector for Strain Gauge Use<br />
(ultra-slim)<br />
P.466<br />
MDP-LC Lightning Surge Protector for Strain Gauge Use P.466<br />
MDK-LC Lightning Surge Protector for Strain gauge Use P.466<br />
MD-LC2<br />
Lightning Surge Protector for Strain gauge Use<br />
(6-wire remote sensing)<br />
P.466<br />
MDK-LV<br />
MD7JS<br />
Lightning Surge Protector for Signal Line with<br />
Excitation Use<br />
Lightning Surge Protector for Self-Synch Use<br />
(ultra-slim)<br />
P.466<br />
P.467<br />
MDP-JS Lightning Surge Protector for Self-Synch Use P.467<br />
MD7PL<br />
Lightning Surge Protector for Pulse Signal<br />
(ultra-slim)<br />
P.467<br />
MMD<br />
Lightning Surge Protector for Standard Signal<br />
Line Use (high discharge current capacity)<br />
***<br />
MDP-SP<br />
Lightning Surge Protector for Low Frequency<br />
Use<br />
P.467<br />
MD72W<br />
Lightning Surge Protector for Two-wire Signal<br />
Loop (ultra-slim)<br />
P.463<br />
MDR2<br />
Lightning Surge Protector for Multi-channel Use<br />
(high discharge current capacity)<br />
P.467<br />
MD72WD<br />
MD73W<br />
MD6N-24<br />
Lightning Surge Protector for Two-wire Signal<br />
Loop (ultra-slim; 2 channels)<br />
Lightning Surge Protector for Three-wire Signal<br />
Loop (ultra-slim)<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (conduit mount, weather-proof)<br />
P.463<br />
P.463<br />
P.464<br />
■■Transmission Line Use<br />
Model Function Page<br />
MD74R<br />
Lightning Surge Protector for RS-485/RS-422<br />
(ultra-slim)<br />
P.468<br />
MDP-4R Lightning Surge Protector for RS-485/RS-422 P.468<br />
MD6N-65<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (conduit mount, weather-proof)<br />
P.464<br />
MDW5-4R<br />
Lightning Surge Protector for RS-485/RS-422<br />
(full-duplex)<br />
P.468<br />
MD6T-24<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (conduit mount, weather-proof)<br />
P.464<br />
MDW2A-4R<br />
Lightning Surge Protector for RS-485/RS-422<br />
(life monitor)<br />
P.468<br />
MD6T-65<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (conduit mount, weather-proof)<br />
P.464<br />
MDCAT<br />
Lightning Surge Protector for Ethernet<br />
(PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T)<br />
P.468<br />
MD6P-24<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (conduit mount, weather-proof)<br />
P.464<br />
MDM5E-A<br />
Lightning Surge Protector for Ethernet<br />
(100 BASE-TX / 10 BASE-T)<br />
P.468<br />
MD6P-65<br />
Lightning Surge Protector for Standard Signal<br />
Line & Pulse Use (conduit mount, weather-proof)<br />
P.464<br />
SHSP 8-Port Ethernet Switch (with surge protector) P.469<br />
460<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
461<br />
Signal Conditioners<br />
Model Function Page<br />
MD7PA<br />
Lightning Surge Protector for PROFIBUS-PA<br />
(ultra-slim)<br />
P.469<br />
MDP-PA Lightning Surge Protector for PROFIBUS-PA P.469<br />
MD7LWA<br />
Lightning Surge Protector for LONWORKS<br />
(ultra-slim, FTT-10A)<br />
P.470<br />
MDP-LWA<br />
MD-DNM<br />
MD-DNS<br />
MD7FB<br />
Lightning Surge Protector for LONWORKS<br />
(FTT-10A)<br />
Lightning Surge Protector for DeviceNet<br />
(load capacity 8A)<br />
Lightning Surge Protector for DeviceNet<br />
(load capacity 2A)<br />
Lightning Surge Protector for FOUNDATION Fieldbus<br />
(ultra-slim)<br />
P.470<br />
P.470<br />
P.470<br />
P.470<br />
MDP-DM3 Lightning Surge Protector for MsysNet Use ***<br />
MDP-EC Lightning Surge Protector for EC-Cable Use ***<br />
MDP-MFA<br />
Lightning Surge Protector for Telemetering Use<br />
(50 bps) ***<br />
MDP-FT<br />
Lightning Surge Protector for Telemetering Use<br />
(3.4 kHz) ***<br />
MD-INS Lightning Surge Protector for ISDN Circuit Use ***<br />
MD-TL<br />
Lightning Surge Protector for Telecommunication<br />
Line Use ***<br />
MDP-TL<br />
MDA-TL<br />
Lightning Surge Protector for Telecommunication<br />
Line Use ***<br />
Lightning Surge Protector for Analog Telecom<br />
Line Use (life monitor) ***<br />
■■Power Supply Use<br />
Model Function Page<br />
MD7AP<br />
MDP-100<br />
MDP-200<br />
Lightning Surge Protector for AC Power Supply<br />
(max. 3A; ultra-slim)<br />
Lightning Surge Protector for AC/DC Power<br />
Supply Use (1A)<br />
Lightning Surge Protector for AC/DC Power<br />
Supply Use (1A)<br />
P.470<br />
P.470<br />
P.470<br />
MA-100 Lightning Surge Protector for Power Supply (2A) P.471<br />
MA-200 Lightning Surge Protector for Power Supply (2A) P.471<br />
MAA<br />
Lightning Surge Protector for Power Supply Use<br />
(5A; high discharge current capacity;<br />
life monitor)<br />
P.471<br />
MAAC<br />
Lightning Surge Protector for Power Supply Use<br />
(5A; high discharge current capacity;<br />
life monitor/surge counter)<br />
P.471<br />
Model Function Page<br />
MH-205A<br />
MH-210A<br />
MH-230A<br />
MH-1201<br />
MH-2201<br />
MH-2203<br />
Lightning Surge Protector for Power Supply Use<br />
(5A) ***<br />
Lightning Surge Protector for Power Supply Use<br />
(10A) ***<br />
Lightning Surge Protector for Power Supply Use<br />
(30A) ***<br />
Lightning Surge Protector for Power Supply Use<br />
(200A) ***<br />
Lightning Surge Protector for Power Supply Use<br />
(200A) ***<br />
Lightning Surge Protector for Power Supply Use<br />
(200A) ***<br />
■■DC Power Supply Use<br />
Model Function Page<br />
MD7DP<br />
MDP-D<br />
MDHA<br />
MDH<br />
Lightning Surge Protector for DC Power Supply<br />
(max. 1.2A; ultra-slim)<br />
Lightning Surge Protector for DC Power Supply<br />
Use<br />
Lightning Surge Protector for Power Supply Use<br />
(DC power use; life monitor)<br />
Lightning Surge Protector for Power Supply Use<br />
(DC power use)<br />
P.472<br />
P.472<br />
P.472<br />
P.472<br />
■■One-port Surge Protector<br />
Model Function Page<br />
MAT2<br />
Lightning Surge Protector for Three-phase Power<br />
Supply<br />
P.473<br />
MAKF One-port Surge Protector for Power Supply Use P.473<br />
■■Accessories<br />
Model Function Page<br />
C-106A-1 M-RESTER Tester P.473<br />
A-33 DIN Rail Mounting Adaptor P.473<br />
MD7F Loop Disconnect Fuse ***<br />
MD7G Terminal Block For Grounding (ultra-slim) ***<br />
MBS Single Mount Adaptor ***<br />
CNB Wiring Bridge ***<br />
BX-W1 Outdoor Housing (weather-proof) P.473<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Lightning Surge Protectors<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
MMAJ<br />
MMA<br />
MMAH<br />
MAX<br />
Lightning Surge Protector for Power Supply Use<br />
(fast responce: 3 nsec.)<br />
Lightning Surge Protector for Power Supply Use<br />
(10A;high discharge current capacity)<br />
Lightning Surge Protector for Power Supply Use<br />
(10A; high speed/high discharge current capacity)<br />
Lightning Surge Protector for Power Supply Use<br />
(5A; high discharge current capacity)<br />
P.471<br />
P.471<br />
P.471<br />
P.472<br />
MAH<br />
Lightning Surge Protector for Power Supply Use<br />
(20A) ***<br />
MMH<br />
Lightning Surge Protector for Power Supply Use<br />
(10–30A; replaceable arrester module)<br />
P.472<br />
MH-105A<br />
MH-110A<br />
MH-130A<br />
Lightning Surge Protector for Power Supply Use<br />
(5A) ***<br />
Lightning Surge Protector for Power Supply Use<br />
(10A) ***<br />
Lightning Surge Protector for Power Supply Use<br />
(30A) ***<br />
To find a product in the list with “***”, visit M-<strong>System</strong> Data Library.<br />
If you cannot find a product here, please contact: info@m-system.co.jp<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
461
J<br />
462 Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
n Standard Signal Line & Pulse Use<br />
4–20mA & Pulse Signal, Ultra-slim Type, with Life Monitor<br />
4–20mA & Pulse Signal, Plug-in Type, with Life Monitor<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
LIFE<br />
MONITOR<br />
Model MD7AST-24 MD7AST-60<br />
Max. Cont. Operat. Volt. (Uc) 30V 70V<br />
Voltage Protection Level (Up) 60V max. 115V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)<br />
Nominal Current (IN)<br />
250 mA<br />
Internal Resistance 4.7 Ω ±10% per line 10 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
LIFE<br />
MONITOR<br />
Model MDPA-24 MDPA-65<br />
Max. Cont. Operat. Volt. (Uc) 30V min. 70V min.<br />
Voltage Protection Level (Up)<br />
45V max.@1kV (100A) 85V max.@1kV (100A)<br />
50V max.@2kV (1kA) 100V max.@2kV (1kA)<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
20 Ω ±10% (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
4–20mA & Pulse Signal, Plug-in Type, with Life Monitor<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
LIFE<br />
MONITOR<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Lightning Surge Protectors<br />
Model MDM2A-24 MDM2A-65<br />
Discharge Voltage 30V min. 70V min.<br />
Max. Surge Voltage 45V max. 85V max.<br />
Response Time<br />
0.1 μsec. max.<br />
Discharge Current<br />
5000A (8/20 μsec.)<br />
Max. Load Current<br />
100 mA<br />
Internal Resistance<br />
Approx. 20 Ω (incl. return)<br />
Test Standard ----<br />
4–20mA & Pulse Signal, Ultra-slim Type<br />
4–20mA & Pulse Signal, Plug-in Type<br />
Model MD7ST-24 MD7ST-60<br />
Max. Cont. Operat. Volt. (Uc) 30V 70V<br />
Voltage Protection Level (Up) 60V max. 115V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)<br />
Nominal Current (IN)<br />
250 mA<br />
Internal Resistance<br />
(Ω ±10%, per line)<br />
4.7 Ω w/o fuse<br />
7.5 Ω w/ fuse<br />
10 Ω w/o fuse<br />
12.5 Ω w/ fuse<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model MDP-24-1 MDP-65-1<br />
Max. Cont. Operat. Volt. (Uc) 30V min. 70V min.<br />
Voltage Protection Level (Up)<br />
40V max.@1kV (100A) 80V max.@1kV (100A)<br />
45V max.@2kV (1kA) 110V max.@2kV (1kA)<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
20 Ω ±10% (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
462<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
463<br />
Signal Conditioners<br />
n Standard Signal Line & Pulse Use<br />
4–20mA & Pulse Signal, Low Profile Type<br />
4–20mA & Pulse Signal, High Speed, Plug-in Type<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Model<br />
MDK-24<br />
Discharge Voltage<br />
30V min.<br />
Max. Surge Voltage<br />
40V max.<br />
Response Time<br />
0.1 μsec. max.<br />
Discharge Current<br />
5000A (8/20 μsec.)<br />
Max. Load Current<br />
100 mA<br />
Internal Resistance 20 Ω ±5%<br />
Test Standard ----<br />
Model MDJST-12 MDJST-24 MDJST-48<br />
Max. Cont. Operat. Volt. (Uc) ±18V ±36V ±60V<br />
Voltage Protection Level (Up) ±30V max. ±50V max. ±90V max.<br />
Response Time<br />
3 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
20 kA (8/20 μs)<br />
Nominal Current (IN)<br />
1A<br />
Internal Resistance<br />
3Ω max.<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
4–20mA & Pulse Signal, High Speed,<br />
High Discharge Current Capacity<br />
Two-Wire Transmitter Loop, Ultra-slim Type<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Model<br />
Discharge Voltage<br />
Max. Surge Voltage<br />
Response Time<br />
Discharge Current<br />
Max. Load Current<br />
Internal Resistance<br />
MMDH-24<br />
±40V min.<br />
±50V max.<br />
4 nanosec.<br />
20000A (8/20 μsec.)<br />
0.1 A<br />
≤0.4 Ω (incl. return)<br />
Model<br />
MD72W-07 MD72W-16 MD72W-32 MD72W-55<br />
Max. Cont. Operat. Volt. (Uc) ±7V ±16V ±32V ±55V<br />
Voltage Protection Level (Up) 20V max. 30V max. 50V max. 80V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)<br />
Nominal Current (IN)<br />
400 mA w/o fuse, 250 mA w/ fuse<br />
Internal Resistance<br />
(Ω ±20%, per line)<br />
2.2 Ω w/o fuse, 4 Ω w/ fuse<br />
Lightning Surge Protectors<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Test Standard ----<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Accessories<br />
Two-Wire Transmitter Loop, 2 channels, Ultra-slim Type<br />
Three-Wire Transmitter Loop, Ultra-slim Type<br />
Model MD72WD-07 MD72WD-16 MD72WD-32<br />
Max. Cont. Operat. Volt. (Uc) ±7V ±16V ±32V<br />
Voltage Protection Level (Up) 30V max. 45V max. 70V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)<br />
Nominal Current (IN)<br />
250 mA<br />
Internal Resistance<br />
4.7 Ω ±20% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MD73W<br />
Max. Cont. Operat. Volt. (Uc) ±32V<br />
Voltage Protection Level (Up)<br />
±60V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20 kA (8/20 μs), 1.0 kA (10/350 μs.)<br />
Nominal Current (IN)<br />
400 mA<br />
Internal Resistance<br />
≤2.2 Ω ±20% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
463
J<br />
464 Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
n Standard Signal Line & Pulse Use<br />
4–20mA & Pulse Signal, Conduit Mount, Weather-Proof<br />
(Leadwire Connection, Pipe Nipple Type)<br />
4–20mA & Pulse Signal, Conduit Mount, Weather-Proof<br />
(Terminal Block Connection Type)<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Model MD6N-24 MD6N-65<br />
Discharge Voltage 30V min. 70V min.<br />
Max. Surge Voltage 40V max. 100V max.<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
100 mA<br />
Internal Resistance<br />
Approx. 22 Ω (incl. return)<br />
Approvals<br />
• FM intrinsically safe<br />
• CENELEC intrinsically<br />
safe (ATEX)<br />
• FM explosion-proof<br />
• CENELEC flameproof<br />
(ATEX)<br />
• FM nonincendive<br />
• FM explosion-proof<br />
• CENELEC flameproof<br />
(ATEX)<br />
4–20mA & Pulse Signal, Conduit Mount, Weather-Proof<br />
(Leadwire Connection, Stopping Plug Type)<br />
Model MD6T-24 MD6T-65<br />
Discharge Voltage 30V min. 70V min.<br />
Max. Surge Voltage 40V max. 100V max.<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
100 mA<br />
Internal Resistance<br />
Approx. 22 Ω (incl. return)<br />
Approvals<br />
• FM intrinsically safe<br />
• CENELEC intrinsically<br />
safe (ATEX)<br />
• CENELEC flameproof<br />
(ATEX)<br />
• FM nonincendive<br />
• CENELEC flameproof<br />
(ATEX)<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Lightning Surge Protectors<br />
Model MD6P-24 MD6P-65<br />
Discharge Voltage 30V min. 70V min.<br />
Max. Surge Voltage 40V max. 100V max.<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
100 mA<br />
Internal Resistance<br />
Approx. 22 Ω (incl. return)<br />
Approvals<br />
• FM intrinsically safe<br />
• CENELEC intrinsically<br />
safe (ATEX)<br />
• FM explosion-proof<br />
• CENELEC flameproof<br />
(ATEX)<br />
• FM nonincendive<br />
• FM explosion-proof<br />
• CENELEC flameproof<br />
(ATEX)<br />
464<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
465<br />
Signal Conditioners<br />
n Sensor Use<br />
Thermocouple, Ultra-slim Type<br />
Thermocouple, Plug-in Type<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Model<br />
MD7TC<br />
Max. Cont. Operat. Volt. (Uc) 7.5V<br />
Voltage Protection Level (Up)<br />
25V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
4.7 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MDP-TC<br />
Max. Cont. Operat. Volt. (Uc)<br />
7.5V min.<br />
Voltage Protection Level (Up) 16V max.@1kV (100A), 20V max.@2kV (1kA)<br />
Response Time<br />
0.1 μsec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
20 Ω ±10% (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
RTD, Ultra-slim Type<br />
RTD, Plug-in Type<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Model<br />
MD7RB<br />
Max. Cont. Operat. Volt. (Uc) ±3V<br />
Voltage Protection Level (Up)<br />
±25V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
5.12 Ω ±0.3%, ±30 ppm/°C per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MDP-RB<br />
Max. Cont. Operat. Volt. (Uc) ±6V min. (B to C), ±3V min. (B or C to A)<br />
Voltage Protection Level (Up)<br />
±40V max.@2kV (1kA) (2 to 3),<br />
±25V max.@2kV (1kA) (2 or 3 to 1)<br />
Response Time<br />
0.1 μsec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
10 Ω ±0.1%, 30 ppm/°C<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Lightning Surge Protectors<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Potentiometer, Ultra-slim Type<br />
Potentiometer, Plug-in Type<br />
Model<br />
MD7PM<br />
Model<br />
MDP-PM<br />
Max. Cont. Operat. Volt. (Uc) 7.5V<br />
Voltage Protection Level (Up)<br />
25V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
4.7 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Max. Cont. Operat. Volt. (Uc)<br />
7.5V min.<br />
Voltage Protection Level (Up) 16V max.@1kV (100A), 25V max.@2kV (1kA)<br />
Response Time<br />
0.1 μsec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
10 Ω ±0.1%, 30 ppm/°C<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
465
J<br />
466 Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
n Sensor Use<br />
Strain Gauge, Ultra-slim Type<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Model MD7LC-0* MD7LC-1<br />
Max. Cont. Operat. Volt. (Uc)<br />
Line Side<br />
±0.2V<br />
Exc. Side<br />
15V<br />
Voltage Protection Level (Up)<br />
Line Side ±15V max. @0.2kV (1.2 / 50 μs) ±40V max. @6kV (1.2 / 50 μs)<br />
Exc. Side 30V max. @0.2kV (1.2 / 50 μs) 50V max. @6kV (1.2 / 50 μs)<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 100A (8/20 μsec.) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN) ---- 250 mA<br />
Internal Resistance ---- 1.5 Ω ±10% per line<br />
Test Standard ---- IEC 61643-21 (Categories C1, C2, D1)<br />
* No CE marking.<br />
Strain Gauge, Plug-in Type<br />
Strain Gauge, Low Profile Type<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Lightning Surge Protectors<br />
Model<br />
MDP-LC<br />
Max. Cont. Operat. Line Side<br />
±0.3V min.<br />
Volt. (Uc) Exc. Side<br />
15V min.<br />
Voltage Protection Line Side<br />
±15V max.<br />
Level (Up) Exc. Side<br />
30V max.<br />
Response Time<br />
5 nanosec. max.<br />
Max. Discharge Line Side 100A (8/20 μsec.), 25A (10/1000 μsec.)<br />
Curr. (Imax) Exc. Side 50A (8/20 μsec.), 25A (10/1000 μsec.)<br />
Test Standard IEC 61643-21 (Category C3)<br />
Model<br />
MDK-LC<br />
Discharge Voltage<br />
Line Side<br />
±0.3V min.<br />
Exc. Side<br />
15V min.<br />
Max. Surge Line Side<br />
±15V max.<br />
Voltage<br />
Exc. Side<br />
30V max.<br />
Response Time<br />
5 nanosec. max.<br />
Discharge Current<br />
Line Side<br />
100A (8/20 μsec.)<br />
Exc. Side<br />
50A (8/20 μsec.)<br />
Test Standard ----<br />
Strain Gauge, 6-wire Remote Sensing<br />
Signal Line with Excitation, Low Profile Type<br />
Model<br />
MD-LC2<br />
Discharge Voltage<br />
Line Side<br />
±0.3V min.<br />
Exc. Side<br />
15V min.<br />
Max. Surge Line Side<br />
±20V max.<br />
Voltage<br />
Exc. Side<br />
40V max.<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
5000A (8/20 μsec.)<br />
Test Standard ----<br />
Model<br />
MDK-LV<br />
Discharge Voltage<br />
Line Side<br />
10V min.<br />
Exc. Side<br />
30V min.<br />
Max. Surge Line Side<br />
20V max.<br />
Voltage<br />
Exc. Side<br />
40V max.<br />
Response Time<br />
0.1 μsec. max.<br />
Discharge Current<br />
5000A (8/20 μsec.)<br />
Test Standard ----<br />
466<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
467<br />
Signal Conditioners<br />
n Sensor Use<br />
Self-Synch, Ultra-slim Type<br />
Self-Synch, Plug-in Type<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Model<br />
MD7JS<br />
Max. Cont. Operat. Volt. (Uc) ±130V<br />
Voltage Protection Level (Up)<br />
±450V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
500 mA<br />
Internal Resistance<br />
2 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MDP-JS<br />
Max. Cont. Operat. Volt. (Uc) ±170V min. (A to B to C)<br />
Voltage Protection Level (Up)<br />
±350V max.@1kV (100A) (1 to 2 to 3),<br />
±450V max.@2kV (1kA) (1 to 2 to 3)<br />
Response Time<br />
0.1 μsec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
500 mA<br />
Internal Resistance<br />
Approx. 2 Ω per wire<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
2-Point Pulse with Common Negative, Ultra-slim Type<br />
Low Frequency Pulse, Plug-in Type<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Model<br />
MD7PL-P<br />
Positive (PNP)<br />
MD7PL-N<br />
Negative (NPN)<br />
Max. Cont. Operat. Volt. (Uc) -30V +30V<br />
Voltage Protection Level (Up) -50V max. +50V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
11 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MDP-SP<br />
Max. Cont. Operat. Volt. (Uc)<br />
14V min.<br />
Voltage Protection Level (Up) 30V max.@1kV (100A), 30V max.@2kV (1kA)<br />
Response Time<br />
0.1 μsec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
50 mA<br />
Internal Resistance 10 Ω ±10%<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Lightning Surge Protectors<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
High Discharge, 8-point Pulse Signal, Terminal Board Type<br />
Model<br />
MDR2-8NY<br />
Negative (NPN)<br />
MDR2-8NA<br />
Negative (NPN) with<br />
Leakage current Indicator<br />
MDR2-8PY<br />
Positive (PNP)<br />
MDR2-8PA<br />
Positive (PNP) with<br />
Leakage current Indicator<br />
Max. Cont. Operat. Volt. (Uc) +30V -30V<br />
Voltage Protection Level (Up) @4kV / 2kA (1.2 / 50 μsec.) +50V +60V -50V -60V<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
10kA<br />
Nominal Current (IN)<br />
150 mA<br />
Internal Resistance 22 Ω ±20%<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
467
J<br />
468 Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
n Transmission Line Use<br />
RS-485/RS-422, Ultra-slim Type<br />
RS-485/RS-422, Plug-in Type<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Model<br />
MD74R<br />
Max. Cont. Operat. Volt. (Uc) ±5V<br />
Voltage Protection Level (Up)<br />
±25V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
2 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MDP-4R<br />
Max. Cont. Operat. Volt. (Uc) ±5V min. (B to C)<br />
Voltage Protection Level (Up) ±20V max. (2 to 3)<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
Approx. 4.5 Ω (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
RS-485/RS-422, Full-duplex<br />
RS-485/RS-422, Plug-in Type with Life Monitor<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
LIFE<br />
MONITOR<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Lightning Surge Protectors<br />
Model<br />
MDW5-4R<br />
Discharge Voltage ±5V min. (6 to 7, 8 to 9)<br />
Max. Surge Voltage ±25V max. (1 to 2, 3 to 4)<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
10kA (8/20 μsec.)<br />
Max. Load Current<br />
100 mA<br />
Internal Resistance<br />
Approx. 4 Ω (incl. return)<br />
Test Standard ----<br />
Model<br />
MDW2A-4R<br />
Discharge Voltage ±5V min. (7 to 8)<br />
Max. Surge Voltage ±25V max. (4 to 5)<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
5000A (8/20 μsec.)<br />
Max. Load Current<br />
100 mA<br />
Internal Resistance<br />
Approx. 5 Ω (incl. return)<br />
Test Standard ----<br />
Accessories<br />
Ethernet, PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T<br />
Ethernet, 100 BASE-TX / 10 BASE-T<br />
Model MDCAT-5E (CAT5e) MDCAT-6 (CAT6)<br />
Max. Cont. Operat. Volt. (Uc) ±6V ±3.3V<br />
Voltage Protection Level (Up) ±15V max. @2kV ±10V max. @2kV<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
100A<br />
Nominal Current (IN)<br />
1A<br />
Internal Resistance<br />
Approx. 0 Ω<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Model<br />
MDM5E-A<br />
Discharge Voltage<br />
±6V min.<br />
Max. Surge Voltage<br />
38V max.<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
500A (8/20 μsec.)<br />
Series Resistance<br />
Approx. 0 Ω<br />
Impulse durability<br />
Category c1<br />
Test Standard IEC 61643-21 : 2000<br />
468<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
469<br />
Signal Conditioners<br />
n Transmission Line Use<br />
8-Port Ethernet Switch (with surge protector)<br />
Surge protector function for each port<br />
◆◆<br />
◆◆<br />
◆◆<br />
Protects Ethernet devices from surges<br />
entering through LAN cables<br />
Surge protector life monitor function with<br />
LED and contact output alarm<br />
Data transfer rate can be fixed<br />
n LAN PORT SPECIFICATIONS<br />
Standards IEEE 802.3, IEEE 802.3u, IEEE 802.3x<br />
Number of ports<br />
8; All ports support AUTO-MDIX*<br />
10 Mbps (10 BASE-T),<br />
Data transfer rate<br />
100 Mbps (100 BASE-TX);<br />
Supports Auto-Negotiation<br />
Cable<br />
10 BASE-T (STP cable, category 5)<br />
100 BASE-TX (STP cable, category 5e)<br />
Maximum segment length 100 meters<br />
Switching<br />
Store & Forward<br />
Flow control<br />
Full duplex PAUSE Frames<br />
Half duplex Back pressure<br />
Buffer<br />
64 KB<br />
MAC address table 1024<br />
PROFIBUS-PA, Ultra-slim Type<br />
Model: SHSP<br />
n SURGE PROTECTOR PERFORMANCE<br />
Compliant standard<br />
EN61000-4-5 level X<br />
Between ports<br />
1kV (combination waveform)**<br />
Port to G<br />
10kV (combination waveform)<br />
FG (shield) to G<br />
15kV (combination waveform)***<br />
Port to FG or G 160V min.<br />
Voltage<br />
protection level<br />
PROFIBUS-PA, Plug-in Type<br />
LIFE<br />
MONITOR<br />
Between each port 160V min.<br />
FG to G<br />
160V min.<br />
(with the shortcircuit bar removed)<br />
* Automatically sensing cable type, straight-through or cross-over.<br />
** RJ-45 connector contact is out of the scope of this protection.<br />
Using twisted-pair (STP) LAN cable is effective to reduce risk of fusing contact.<br />
*** With the shortcircuit bar<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Model<br />
MD7PA<br />
Max. Cont. Operat. Volt. (Uc) ±32V<br />
Voltage Protection Level (Up)<br />
±60V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
400 mA<br />
Internal Resistance<br />
1.5 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MDP-PA<br />
Max. Cont. Operat. Volt. (Uc)<br />
27V min.<br />
Voltage Protection Level (Up)<br />
±60V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
500 mA<br />
Internal Resistance<br />
≤3.3 Ω (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Lightning Surge Protectors<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
469
J<br />
470 Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
n Transmission Line Use<br />
LONWORKS (FTT-10A), Ultra-slim Type<br />
LONWORKS (FTT-10A), Plug-in Type<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Model<br />
MD7LWA<br />
Max. Cont. Operat. Volt. (Uc)<br />
±1.5V min.<br />
Voltage Protection Level (Up)<br />
±30V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
≤3.3 Ω (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model<br />
MDP-LWA<br />
Max. Cont. Operat. Volt. (Uc)<br />
±1.5V min.<br />
Voltage Protection Level (Up)<br />
±40V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
100 mA<br />
Internal Resistance<br />
≤3.3 Ω (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
DeviceNet<br />
FOUNDATION Fieldbus, Ultra-slim Type<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Lightning Surge Protectors<br />
Model MD-DNM MD-DNS<br />
Discharge Voltage<br />
Line Side<br />
±5V min.<br />
Exc. Side<br />
26V min.<br />
Max. Surge Line Side<br />
±15V max.<br />
Voltage<br />
Exc. Side<br />
120V max.<br />
Response Time<br />
0.1 μsec. max.<br />
Discharge Current<br />
Line Side<br />
Exc. Side<br />
1500A<br />
Load Capacity 8A 2A<br />
Test Standard ----<br />
Model<br />
MD7FB<br />
Max. Cont. Operat. Volt. (Uc) ±32V<br />
Voltage Protection Level (Up)<br />
±60V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN)<br />
400 mA<br />
Internal Resistance<br />
1.5 Ω ±10% per line<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
n Power Supply Use<br />
3A Load Rating, Ultra-slim Type<br />
1A Load Rating, Plug-in Type<br />
Model MD7AP-100 MD7AP-200<br />
Max. Cont. Operat. Volt. (Uc) 140V AC 275V AC<br />
Voltage Protection Level (Up) ±550V max. ±850V max.<br />
Response Time<br />
20 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
10kA (8/20 μsec.)<br />
Nominal Current (IN)<br />
3A<br />
Test Standard IEC 61643-21 (Categories C1, C2)<br />
Model MDP-100 MDP-200<br />
Max. Line Volt. (Uc) 120V AC 250V AC<br />
Voltage Protection Level (Up) 400V max. 800V max.<br />
Response Time<br />
0.1 μsec. max.<br />
Max. Discharge Curr. (Imax)<br />
1000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
1A<br />
Internal Resistance<br />
≤0.4 Ω (incl. return)<br />
Test Standard<br />
IEC 61643-1 (Class III)<br />
470<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
471<br />
Signal Conditioners<br />
n Power Supply Use<br />
2A Load Rating, Plug-in Type<br />
5A Load Rating, with Life Monitor<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
LIFE<br />
MONITOR<br />
Indicators<br />
Limit Alarms<br />
Model MA-100 MA-200<br />
Discharge Voltage 190V min. 410V min.<br />
Max. Surge Voltage 350V max. 700V max.<br />
Response Time<br />
0.1 μsec. max.<br />
Discharge Current<br />
1000A (8/20 μsec.)<br />
Max. Load Current<br />
2A<br />
Voltage Drop<br />
≤2V (50/60Hz)<br />
Test Standard ----<br />
Model MAA-100 MAA-200<br />
Discharge Voltage 190V min. 410V min.<br />
Max. Surge Voltage 380V max. 700V max.<br />
Response Time<br />
0.01 μsec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
5A<br />
Internal Resistance<br />
≤0.5 Ω (incl. return)<br />
Test Standard ----<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
5A Load Rating, with Life Monitor / Surge Counter<br />
10A/20A/30A Load Rating, Wall-mounted,<br />
High Speed, High Discharge Current Capacity<br />
LIFE<br />
MONITOR<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Model MAAC-100 MAAC-200<br />
Discharge Voltage 190V min. 410V min.<br />
Max. Surge Voltage 400V max. 750V max.<br />
Response Time<br />
0.01 μsec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
5A<br />
Internal Resistance<br />
≤0.5 Ω (incl. return)<br />
Test Standard ----<br />
Model MMAJ-100 MMAJ-200<br />
Max. Cont. Operat. Volt. (Uc) 132V AC 264V AC<br />
Voltage Protection Level (Up) 900V max. 1500V max.<br />
Response Time<br />
3 nanosec.<br />
Max. Discharge Curr. (Imax)<br />
10kA, 20kA<br />
Max. Load Current<br />
10A, 20A, 30A<br />
Test Standard<br />
IEC 61643-1 (Class II, III)<br />
Lightning Surge Protectors<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
10A Load Rating, Wall-mounted<br />
10A Load Rating, Wall-mounted,<br />
High Speed, High Discharge Current Capacity<br />
Model MMA-100 MMA-200<br />
Discharge Voltage 190V min. 410V min.<br />
Max. Surge Voltage 350V max 700V max.<br />
Response Time<br />
0.01 μsec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
10A<br />
Internal Resistance<br />
≤0.5 Ω (incl. return)<br />
Test Standard ----<br />
Model MMAH-100 MMAH-200<br />
Discharge Voltage 190V min. 410V min.<br />
Max. Surge Voltage 400V max 750V max.<br />
Response Time<br />
4 nanosec.<br />
Discharge Current<br />
20000A (8/20 μsec.)<br />
Max. Load Current<br />
10A<br />
Internal Resistance<br />
≤0.5 Ω (incl. return)<br />
Test Standard ----<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
471
J<br />
472 Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
Signal Conditioners<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
n Power Supply Use<br />
5A Load Rating, Replaceable Surge Absorber<br />
Medium Capacity 10A, 30A, Replaceable Surge Absorber<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
Model MAX-100 MAX-200<br />
Discharge Voltage 190V min. 410V min.<br />
Max. Surge Voltage 350V max. 700V max.<br />
Response Time<br />
0.01 μsec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
5A<br />
Internal Resistance<br />
≤0.5 Ω (incl. return)<br />
Test Standard ----<br />
Model<br />
MMH-110 MMH-130 MMH-210 MMH-230<br />
Discharge Voltage 130V min. 285V min.<br />
Max. Surge Voltage 350V max. 700V max.<br />
Response Time<br />
0.01 μsec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current 10A 30A 10A 30A<br />
Voltage Drop<br />
≤1V (50/60Hz)<br />
Test Standard ----<br />
n DC Power Supply Use<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
DC Power Supply Line, 1.2A Load Rating, Ultra-slim Type<br />
DC Power Supply Line, 1A Load Rating, Plug-in Type<br />
Standard Signal<br />
Line & Pulse Use<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
Accessories<br />
Lightning Surge Protectors<br />
Model MD7DP-12 MD7DP-24<br />
Max. Cont. Operat. Volt. (Uc) 14V 27V<br />
Voltage Protection Level (Up) ±150V max. ±170V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax) 20kA (8/20 μsec.), 1.0kA (10/350 μsec.)<br />
Nominal Current (IN) 1.2A<br />
Internal Resistance<br />
≤0.8 Ω (incl. return)<br />
Test Standard IEC 61643-21 (Categories C1, C2, D1)<br />
Model MDP-D12 MDP-D24<br />
Max. Cont. Operat. Volt. (Uc) 14V min. 30V min.<br />
Voltage Protection Level (Up) 20V max. 40V max.<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
5000A (8/20 μsec.)<br />
Nominal Current (IN)<br />
1A<br />
Internal Resistance<br />
≤0.6 Ω (incl. return)<br />
Test Standard<br />
IEC 61643-1 (Class III)<br />
DC Power Supply Line, 5A Load Rating, with Life Monitor<br />
DC Power Supply Line, 5A Load Rating, Plug-in Type<br />
LIFE<br />
MONITOR<br />
Model MDHA-12 MDHA-24<br />
Discharge Voltage ±15V min. ±30V min.<br />
Max. Surge Voltage ±80V max. ±120V max.<br />
Response Time<br />
4 nanosec. max.<br />
Discharge Current<br />
10000A (8/20 μsec.)<br />
Max. Load Current<br />
5A<br />
Internal Resistance<br />
≤0.2 Ω (incl. return)<br />
Test Standard ----<br />
Model MDH-12 MDH-24 MDH-48<br />
Discharge Voltage 24V min. 50V min. 88V min.<br />
Max. Surge Voltage 70V max. 140V max. 210V max.<br />
Response Time<br />
0.1 μsec. max.<br />
Discharge Current<br />
2000A (8/20 μsec.)<br />
Max. Load Current<br />
5A<br />
Internal Voltage Drop<br />
≤1V<br />
Test Standard ----<br />
472<br />
Data sheets available on Web in PDF. Visit M-<strong>System</strong> Data Library at www.m-system.co.jp ISP ’12
Lightning Surge Protectors for Electronics Equipment M-RESTER<br />
J<br />
473<br />
Signal Conditioners<br />
n One-port Surge Protector<br />
Three-phase Power Supply<br />
Connected in parallel between the power and<br />
ground lines regardless of load current<br />
◆◆<br />
◆◆<br />
Applicable to single phase 2/3-wire and threephase<br />
3/4- wire system.<br />
Degraded head element is automatically separated<br />
from the power lines by the incorporated<br />
thermal breaker, and the LED lamp (turns off)<br />
and the relay contact alerts the failure status.<br />
Model MAT2-240 MAT2-440<br />
Max. Cont. Operat. Volt. (Uc) 240V AC 440V AC<br />
Voltage Protection Level (Up) 1500V 2500V<br />
Response Time<br />
4 nanosec. max.<br />
Max. Discharge Curr. (Imax)<br />
20kA (8/20 μsec.), 40kA (8/20 μsec.)<br />
Nominal Current (IN)<br />
10kA (8/20 μsec.), 20kA (8/20 μsec.)<br />
Test Standard<br />
IEC 61643-1 (Class II)<br />
Two-wire<br />
Signal Conditioners<br />
Power Transducers<br />
Indicators<br />
Limit Alarms<br />
Gateway,<br />
Remote I/O<br />
Paperless Recording<br />
<strong>System</strong><br />
PC Recorder<br />
Electric Actuators<br />
& Position Sensors<br />
Lightning Surge<br />
Protectors<br />
One-port Surge Protector<br />
Connected in parallel between the power and<br />
ground lines regardless of load current<br />
◆◆<br />
◆◆<br />
Thermal breaker ensures degraded head<br />
element to be automatically separated from the<br />
power lines to prevent overheating.<br />
Head-base connection is keyed so that only a<br />
head element of correct line voltage can be<br />
mounted.<br />
Lightning Surge<br />
Protectors<br />
M-RESTER<br />
Standard Signal<br />
Line & Pulse Use<br />
Model MAKF-120 MAKF-240 MAKF-280 MAKF-400 MAKF-480<br />
Uc (AC) 150V 275V 320V 440V 530V<br />
Discharge Voltage 250V min. 420V min. 460V min. 670V min. 820V min.<br />
Up<br />
@1.0kA (8/20ms) 600V max. 1000V max. 1100V max. 1500V max. 1800V max.<br />
@1.5kA (8/20ms) 650V max. 1100V max. 1200V max. 1700V max. 2100V max.<br />
Response Time<br />
20 nanosec. max.<br />
Max. Discharge Curr.<br />
20kA × twice (8/20 μsec.)<br />
Test Standard ----<br />
Lightning Surge Protectors<br />
Sensor Use<br />
Transmission Line<br />
Use<br />
Power Supply Use<br />
DC Power Supply<br />
Use<br />
One-port Surge<br />
Protector<br />
n Accessories<br />
Accessories<br />
M-RESTER Tester<br />
model: C-106A-1<br />
DIN Rail Mounting Adaptor<br />
model: A-33<br />
Outdoor Housing (weather-proof)<br />
model: BX-W1<br />
ISP ’12<br />
Specifications are subject to change without notice.<br />
473