<strong>3RW3</strong> <strong>semiconductor</strong> <strong>motor</strong> <strong>control</strong> <strong>unit</strong><br />
Conductor cross-sections<br />
Screw-type terminals<br />
Auxiliary conductors:<br />
(1 or 2 conductors connectable) Single-core mm 2 2 x (0.5 to 1.5); 2 x (0.75 to 2.5) in acc. with IEC 60 947; max. 2 x (0.75 to 4)<br />
for standard screwdrivers<br />
Finely stranded with wire mm 2 2 x (0.5 to 1.5); 2 x (0.75 to 2.5)<br />
end ferrule<br />
size 2 and Pozidriv 2<br />
AWG cables,<br />
single- or multi-core AWG 2 x (18 to 14)<br />
- Terminal screws M 3<br />
- Tightening torque Nm<br />
lb.in<br />
Main conductors:<br />
0.8 to 1.0<br />
7.1 to 8.9<br />
Single-core mm 2 2 x (0.75 to 16)<br />
Finely stranded with wire<br />
end ferrule<br />
mm 2 2 x (0.75 to 16)<br />
1 x (0.75 to 25)<br />
Multi-core mm 2 2 x (0.75 to 25)<br />
1 x (0.75 to 35)<br />
AWG cables,<br />
single- or multi-core AWG 2 x (18 to 3)<br />
1 x (18 to 2)<br />
2 x (10 to 50)<br />
1 x (10 to 70)<br />
2 x (10 to 1/0)<br />
1 x (10 to 2/0)<br />
- Terminal screws M 6, box terminal, PZ2 M6 (Allan screw)<br />
- Tightening torque Nm<br />
lb.in<br />
3 to 4.5<br />
27 to 40<br />
4 to 6<br />
35 to 53<br />
General specifications<br />
Standard<br />
Parameters<br />
EMC noise imm<strong>unit</strong>y<br />
Electrostatic discharge (ESD) IEC 1000-4-2, Severity 3: 6/8 kV<br />
El. magn. RF fields IEC 1000-4-3 Frequency range: 80 to 1000 MHz with 80 % at 1 kHz<br />
Severity 3, 10 V/m<br />
Conducted RF disturbance IEC 61000-4-6<br />
EN 60 947-4-2<br />
SN-IACS<br />
Frequency range: 80 MHz to 1000 MHz with 80 %<br />
at 1 kHz<br />
10 V at 0.15 MHz to 80 MHz<br />
3 V at 10 kHz to 80 MHz<br />
Burst IEC 1000-4-4 Severity 3: 1/2 kV<br />
Surge IEC 1000-4-5 Severity 3: 1/2 kV<br />
EMC emitted interference<br />
EMC radio interference intensity CISPR 11/09.1990 Limit value of class B at 30 MHz to 1000 MHz<br />
Radio interference voltage CISPR 11/09.1990<br />
EN 60 947-4-2<br />
(0.15 MHz to 30 MHz): device class A (industry)<br />
1 ) IP20 only with attached box terminal (delivery state). Without box terminal IP00.<br />
2 ) Device class B (public power supply networks) is complied with only in the case of variants <strong>3RW3</strong>.-1AB0. with <strong>control</strong> supply voltage UC<br />
of 24 V. For the <strong>3RW3</strong>.-1A.1. variants with a <strong>control</strong> supply voltage UC of 110 V to 230 V, single-stage filters (e.g. type B84143-A...) must be<br />
connected upstream.<br />