<strong>Integrated</strong> <strong>Shelf</strong> <strong>Power</strong> <strong>Systems</strong><br />

<strong>PPS10</strong> <strong>Series</strong><br />

<strong>PPS10</strong>.48/3300<br />

Up to 60 Amps @ 48V 6U High - 19" Wide Rack Mountable Chassis<br />

<strong>PPS10</strong>.48/4400<br />

Up to 80 Amps @ 48V 6U High - 23" Wide Rack Mountable Chassis<br />

Description<br />

<strong>PPS10</strong> power systems provide large<br />

power plant features in cost-effective,<br />

rack-mounted form factors. These scalable<br />

power solutions provide rectification,<br />

control, and power distribution all in one<br />

<strong>com</strong>pact system and offer extensive local<br />

and remote power plant and battery<br />

monitoring. Please contact <strong>Power</strong>-One<br />

for information regarding stand-alone<br />

configurations including backup batteries.<br />

Messages and alarms from the controller<br />

are displayed on the front panel LCD<br />

display and via optional PC-based<br />

PowCom TM<br />

software. In addition, each site’s<br />

unique system configuration data can be<br />

remotely entered and recalled through a<br />

user-programmable, password-protected<br />

interface.<br />

Features<br />

<strong>PPS10</strong>.48/5500<br />

Up to 100 Amps @ 48V 12U High - 19" Wide Rack Mountable Chassis<br />

◗ Scalable systems can be quickly expanded to ultimate capacity:<br />

◗ 15 to 100 amp capacity at 48V<br />

◗ Contact <strong>Power</strong>-One for 24V ratings<br />

◗ 115 or 230 VAC single or three-phase input with PFC.<br />

◗ Convection cooled, up to 92% efficient, rectifiers have MTBF’s<br />

>1 million hours<br />

◗ Single point voltage adjustment.<br />

◗ True plug-and-play rectifiers and controllers.<br />

◗ Can ac<strong>com</strong>modate up to 20 circuit breakers from 2 to 63 amps.<br />

◗ LCD display for self-guided controller operation.<br />

◗ Interfaces include RS232, SNMP, and Form “C” dry alarm contacts<br />

with grouped alarms.<br />

◗ Intelligent battery management:<br />

◗ Temperature <strong>com</strong>pensation (requires optional cables).<br />

◗ Programmable battery load testing with data logging.<br />

◗ Battery module voltage monitoring (requires optional cables).<br />

◗ Symmetry (requires optional cables).<br />

◗ Programmable low voltage disconnect.<br />

◗ SNMP interface adapter available.<br />

◗ International standards <strong>com</strong>pliance.<br />

PPS5 <strong>Series</strong> <strong>PPS10</strong> <strong>Series</strong> PCU5 and PCU10<br />

Controllers


Rectifier Overview<br />

PMP10.24A SIC PMP11.48 SIC PMP10.24 SIC-110 PMP10.48 SIC-110<br />

Input Voltage 161-276VAC 161-276VAC 80-138VAC 80-138VAC<br />

Single Phase Single Phase Single Phase Single Phase<br />

44-66Hz 44-66Hz 44-66Hz 44-66Hz<br />

Input Current


<strong>Integrated</strong> <strong>Shelf</strong> <strong>Power</strong> <strong>Systems</strong><br />

<strong>PPS10</strong> <strong>Series</strong><br />

LCD display used for menu-driven<br />

programming and monitoring functions.<br />

See PCU10 controller data sheet<br />

Red LED indicates rectifier has<br />

been shut down by internal<br />

protection circuitry due to high<br />

output voltage condition<br />

Message LED (yellow) proactively<br />

indicates a potential system<br />

warning message is available<br />

by viewing the LCD display<br />

Alarm LED (red) indicates a system<br />

failure message is available by<br />

viewing the LCD display<br />

Red LED indicates one of<br />

the following conditions<br />

has occurred:<br />

High voltage shutdown,<br />

Low voltage/rectifier failure<br />

Output of RS232 interface can be displayed using PowCom TM<br />

Software<br />

Pushbuttons and an LCD display<br />

are used to set user-defined<br />

parameters, such as plant voltage.<br />

See PCU10 data sheet for<br />

<strong>com</strong>plete description


<strong>Integrated</strong> <strong>Shelf</strong> <strong>Power</strong> <strong>Systems</strong><br />

<strong>PPS10</strong> <strong>Series</strong><br />

TECHNICAL SPECIFICATIONS<br />

ELECTRICAL<br />

SPECIFICATIONS: <strong>Power</strong> Factor >0.99 (50 - 100% load)<br />

AC Transient<br />

Voltage Regulation +/- 1%<br />

Transient Response<br />

Load Sharing<br />

Ripple<br />

3000V, 2 Joules<br />

+/- 5% at load variations 10-90% or 90-10%, recovery time 10 mS<br />

5% of nominal current<br />

Radiated RFI EN 50081-1<br />

Psophometric Noise<br />

Switching Frequency<br />


<strong>Integrated</strong> <strong>Shelf</strong> <strong>Power</strong> <strong>Systems</strong><br />

PCU5 and PCU10 Controllers<br />

Description<br />

The PCU5<br />

Controller is used<br />

in PPS5 <strong>Power</strong><br />

<strong>Systems</strong>.<br />

The PCU5 and PCU10 provide monitoring and<br />

control for the PPS5 and <strong>PPS10</strong> power<br />

systems. These hot-swappable controller<br />

modules supervise AC inputs, output voltages<br />

and currents, rectifier performance, battery<br />

condition, and breaker status. Visual<br />

notification of an alarm condition is provided<br />

with an LED. A description of the exact alarm<br />

condition is provided with an LCD display.<br />

Additionally, four Form “C” contacts are<br />

provided to indicate a failure in a pre-assigned<br />

group of alarms:<br />

◗ Critical: Distribution breaker, battery<br />

disconnect, low voltage, high voltage.<br />

◗ Urgent: Battery breaker, high temperature,<br />

battery test failure, battery symmetry<br />

failure, multiple rectifier failures.<br />

◗ AC Loss: Loss of AC.<br />

◗ Service: Failure of one rectifier, rectifier<br />

capacity.<br />

Features<br />

◗ User controls and interfaces:<br />

The PCU10<br />

Controller is<br />

used in <strong>PPS10</strong><br />

<strong>Power</strong> <strong>Systems</strong>.<br />

◗ Simple menu-guided operation using front panel<br />

mounted pushbuttons and an LCD display.<br />

◗ User-selectable alarm parameters.<br />

◗ Data logging of last 40 events.<br />

◗ SNMP interface adapter available.<br />

◗ RS232 Interface and Form “C” dry alarm contacts.<br />

◗ Compatible with PowCom TM<br />

PC-based software.<br />

◗ Intelligent battery management:<br />

◗ Temperature <strong>com</strong>pensation with programmable<br />

<strong>com</strong>pensation factor.<br />

◗ Automatic and manual load testing.<br />

◗ Battery voltage and symmetry monitoring.<br />

◗ Capacity testing.<br />

◗ Low voltage disconnect.<br />

PPS5 <strong>Series</strong> <strong>PPS10</strong> <strong>Series</strong> PCU5 and PCU10<br />

Controllers


Extensive Battery Management Capabilities<br />

Battery Symmetry<br />

Symmetry cables monitor the voltage and voltage variances of each battery module within a<br />

string of batteries. A symmetry alarm is issued if any of the modules exceed the user-defined<br />

variances.<br />

Battery Test<br />

A battery test may be performed manually as required, or automatically up to four times per<br />

year. During the test cycle, the controller automatically decreases the rectifier voltage in<br />

order to transfer the load to the batteries. Measurement of battery voltage, current, time,<br />

Ah, and symmetry deviation is recorded for up to three strings of batteries.<br />

The system will automatically return to the normal rectifier float voltage when<br />

user-programmable end voltage, Ah or end time is reached. A battery failure alarm is<br />

generated if the voltage falls below a preset level before the end of a test, or if<br />

symmetry deviation exceeds the preset level. Data from the last ten tests is archived<br />

and can be downloaded into a spreadsheet.<br />

Low Voltage Disconnect<br />

This feature provides automatic disconnection of the battery to prevent deep discharge.<br />

Disconnection and reconnection thresholds are user adjustable.<br />

Battery Current Monitor<br />

Battery current is displayed on the front panel LCD for use during periodic maintenance to<br />

track the float current of the batteries.<br />

Temperature Compensation<br />

Temperature <strong>com</strong>pensation automatically adjusts the float voltage according to the ambient<br />

temperature. A dedicated threshold setting is provided for the high temperature alarm.


<strong>Integrated</strong> <strong>Shelf</strong> <strong>Power</strong> <strong>Systems</strong><br />

PCU5 and PCU10 Controllers<br />

Available with Advanced PowCom TM<br />

Both controllers can be interfaced with PowCom TM<br />

software to provide<br />

PC-based access to power plant operating information from multiple sites.<br />

This software was specifically developed to provide point-and-click data logging,<br />

analysis, and display capabilities for critical power plant performance and battery<br />

management data.<br />

Software<br />

Extensive Interface and Data Logging Capabilities<br />

Data is received through the RS232 interface of the PCU5 and PCU10<br />

controllers. Data collection can be automated by defining a password protected<br />

list of up to 100 systems for modem dial up. A dedicated log function provides<br />

the user with a selection of data logging parameters and intervals. This data<br />

logging information is saved in a separate downloadable file.<br />

PowCom TM<br />

provides easy user access to set<br />

points for battery functions such as test,<br />

equalize, <strong>com</strong>pensation, and alarm limits.<br />

PowCom TM<br />

software is <strong>com</strong>patible with PC’s utilizing Windows v.3.1 or higher,<br />

Windows95, or Windows NT. Hayes-<strong>com</strong>patible modems that <strong>com</strong>municate at<br />

2400, 4800 or 9600 baud rate are required.<br />

<strong>Power</strong>ful Analysis and Display<br />

System data displayed by PowCom TM<br />

software includes system voltage, load<br />

current, battery current, rectifier output current, rectifier status, temperature<br />

reading, and the status of alarm relays. Alarm information displayed for the last<br />

40 events includes alarm symbol and text, and time/date of occurrences.<br />

PowCom TM<br />

data can also be exported to other programs. <strong>Power</strong>ful statistical and<br />

historical analysis can be presented in spreadsheet and graphical formats.<br />

Intelligent Battery Management<br />

Programmable battery test parameters include battery test interval, duration,<br />

Ah limit, and end voltage. The results of the last 10 tests may be downloaded to<br />

a PC for graphical analysis. Multiple discharge curves can be shown on the same<br />

graph for <strong>com</strong>parison.<br />

Programmable battery equalization parameters include interval, duration, and<br />

voltage. In addition, low-voltage disconnect and reconnect points, temperature<br />

<strong>com</strong>pensation slope, and other system parameters may be remotely set with<br />

PowCom TM . Parameters from the system may be exported to a data file, edited<br />

offline, and remotely uploaded to the controller.<br />

Graphical presentation of battery test data<br />

facilitates <strong>com</strong>parison with future test<br />

results for battery integrity trend analysis.<br />

Critical system parameters, such<br />

as rectifier and alarm status, are<br />

concisely displayed. Clicking on the<br />

alarm button displays an alarm<br />

history screen depicting the last<br />

40 alarm events.


<strong>Integrated</strong> <strong>Shelf</strong> <strong>Power</strong> <strong>Systems</strong><br />

PCU5 and PCU10 Controllers<br />

ORDERING INFORMATION<br />

PCU5 PCU5.24 PCU5.48<br />

<strong>Power</strong> Plant Compatibility 24V PPS5 48V PPS5<br />

Dimensions (H x W x D) 5.15" x 2.5" x 9.25" 5.15" x 2.5" x 9.25"<br />

(12.9cm x 6.2cm x 23.1cm)<br />

(12.9cm x 6.2cm x 23.1cm)<br />

3U height<br />

3U height<br />

Weight 1.0 lbs 1.0 lbs<br />

Ambient Operating Temperature -25 to +55°C -25 to +55°C<br />

Storage Temperature -50 to +85°C -50 to +85°C<br />

Vibration and Shock IEC 721-3-3 IEC 721-3-3<br />

PCU10 PCU10.24 PCU10.48<br />

<strong>Power</strong> Plant Compatibility 24V <strong>PPS10</strong> 48V <strong>PPS10</strong><br />

Dimensions (H x W x D) 10.5" x 2.5" x 9.25" 10.5" x 2.5" x 9.25"<br />

(25.9cm x 6.2cm x 23.1cm)<br />

(25.9cm x 6.2cm x 23.1cm)<br />

6U height<br />

6U height<br />

Weight 1.1 lbs 1.1 lbs<br />

Ambient Operating Temperature -25 to +55°C -25 to +55°C<br />

Storage Temperature -50 to +85°C -50 to +85°C<br />

Vibration and Shock IEC 721-3-3 IEC 721-3-3<br />

Note: All specifications are subject to change without notification.<br />

www.power-one.<strong>com</strong><br />

Revised: 6/01 ISC601-A