Founded In 1995

randj.sk

Founded In 1995

Fully automatic single-gas station for

recovering, recycling, and recharging R134

refrigerant.

AUTOMATIC FUNCTIONS:

ECK 2900-UP

ECK 2500-UP

RECOVERY

OIL

DISCHARGE

VACUUM

TRACER

optional

OIL REINTE-

GRATION

GAS

CHARGING

STANDARD FEATURES

• LEAK TEST: automatic during the vacuum phase.

• ONBOARD BOTTLE FILLING: automatic.

• AUTOMATIC DISCHARGE of non-condensable gases from the bottle.

• SERVICE ALARM: acoustic and visual, for maintenance and filter

replacement request.

• USB PORT for software updates.

• REFRIGERANT MANAGEMENT: for creating a customized archive of all

refrigerant transactions.

• OPERATOR CODE: for assigning an operator password to protect against

unauthorized use of the station.

• DISTRIBUTOR GROUP: built-in, patented unit optimized for top

performance and dependability.

• DATABASE ADVANCED: integrated database vehicle + truck allowing the

user to enter new vehicle models.

• FLUSHING SOFTWARE for automatic flushing of series A/C systems. For

use with AEK102-N7.

• HFO UPgradable: Ecotechnics charging machines can now be upgraded for use

with the new HFO1234YF refrigerant, using a specific transformation kit

• HERMETICALLY-SEALED NEW-OIL CARTRIDGE

OPTIONS

SANIFLUX (SANI+): the first sanitizing

system integrated in an A/C charging

station.

SANI

PATENT PENDING

FLUSHING KIT (AEK102-N7): for flushing

the A/C system with refrigerant. External

bottle and metal adapters included.

A/C DIAGNOSIS MODULE (DIAKIT):

integrated, for all types of A/C systems,

featuring printout of diagnosis and

problem solution.

AUTOMATIC TRACER KIT (UVKIT-7)

featuring collapsible cartridges for

injecting a predetermined quantity of

tracer.

NITROGEN BOTTLE CONNECTOR (N2)

(bottle not included): the station

automatically charges the A/C system with

nitrogen and checks for leaks, monitoring

pressure drops and giving a leak alarm.

STATIC DIAGNOSIS KIT (KITSTA001.00)

for diagnosing A/C systems.

HYBRID:

hybrid-vehicle service

tube flushing function


HYBRID

ECK2900-UP: K1P0A000000R STANDARD VERSION

ECK2500-UP: K1Q0A000000R STANDARD VERSION

Type of refrigerant R134a

Service procedure Fully automatic or manual

Voltage

220-240 V - 50/60 Hz

Scale resolution 10 g

Oil scale resolution 5 g

Working temperature range 11/49°C

Filter system 2 filters for humidity

Vacuum pump 100 liter/min capacity, 0.1 mbar vacuum level

Sealed compressor 12 cc, high-pressure

Recovery speed 300 g/min in liquid phase

Refrigerant bottle 22 litres, refillable

Hoses

3 metres

Overall size

55 x 60 x 105 cm

Weight

90 kg

Thermal printer Standard equipment

Pressure gauges Class 1

Display

Graphic

Bottle temperature sensor Integrated

Bottle heater Automatic

7