Technical data<br />

Designation Screw lead Nominal force Peak force Linear speed Standard st<strong>ro</strong>ke Dynamic load<br />

Up to Up to Up to<br />

mm kN kN mm/s mm kN<br />

SRSA 2505 5 40,7 81,7 1) 333 0 to 400 63,3<br />

SRSA 2510 10 37,5 90,5 1) 450 0 to 400 72,6<br />

7<br />

SRSA 3005 5 52,9 1<st<strong>ro</strong>ng>02</st<strong>ro</strong>ng>,8 1) 325 0 to 500 92<br />

SRSA 3<st<strong>ro</strong>ng>01</st<strong>ro</strong>ng>0 10 49,9 97,1 1) 650 0 to 500 97,6<br />

SRSA 3905 5 63,3 123,1 1) 279,2 2) 0 to 800 129,2<br />

SRSA 3910 10 61 130,1 1) 350 0 to 800 138,5<br />

SRSA 3915 15 61,5 141,7 1) 650 0 to 800 138,5<br />

SRSA 4805 5 106,5 248 1) 220,8 2) 0 to 1 000 198,1<br />

SRSA 4810 10 95,3 187,2 1) 350 0 to 1 000 207,9<br />

SRSA 4815 15 130,4 2<st<strong>ro</strong>ng>02</st<strong>ro</strong>ng>,4 1) 412,5 0 to 1 000 207,9<br />

SRSA 4820 20 86,3 169,6 1) 550 0 to 1 000 207,9<br />

SRSA 6<st<strong>ro</strong>ng>01</st<strong>ro</strong>ng>0 10 161,9 318,1 1) 275 0 to 1 300 303,9<br />

SRSA 6<st<strong>ro</strong>ng>01</st<strong>ro</strong>ng>5 15 162,3 318,7 1) 462,5 0 to 1 300 303,9<br />

SRSA 6<st<strong>ro</strong>ng>02</st<strong>ro</strong>ng>0 20 142,7 251,9 1) 666,7 0 to 1 300 303,9<br />

SRSA 7510 10 255,5 451 1) 250 2) 0 to 1 500 471,6<br />

SRSA 7515 15 240,2 271,3 357 2) 0 to 1 500 471,6<br />

SRSA 7520 20 199,4 223,9 466,7 0 to 1 500 471,6<br />

SVSA 32<st<strong>ro</strong>ng>01</st<strong>ro</strong>ng> 1 40,6 78,3 1) 10,4 2) 0 to 1000 64,3<br />

SVSA 40<st<strong>ro</strong>ng>01</st<strong>ro</strong>ng> 1 62,3 121,3 1) 8,3 2) 0 to 1000 79,1<br />

SVSA 50<st<strong>ro</strong>ng>01</st<strong>ro</strong>ng> 1 110,2 214,4 1) 6,7 2) 0 to 1000 138,5<br />

SLSA 2525 25 8,2 18,8 1500 2) 0 to 500 22,6<br />

SLSA 4040 40 12,4 18,7 1500 2) 0 to 1 200 53,3<br />

1) Peak force to be used only in static phases. For dynamic ones, this value must be limited inside the motion cont<strong>ro</strong>ller at 80 % of the dynamic load by the user. Please contact SKF.<br />

2) Maximum speed. This value must be limited inside the motion cont<strong>ro</strong>ller by the user. Please contact SKF.<br />