1<br />

Part Number<br />

High Capacity Relief<br />

R962-31<br />

(Types R110 and R622)<br />

Capacity<br />

BTU/HR Propane<br />

Inlet Connection<br />

Inches<br />

Outlet Connection<br />

Inches<br />

600,000 1/4 Inv. Flare 1/2 FNPT 3/4 FNPT<br />

1. Capacity based on 30 psig (2,1 bar) inlet pressure, 11 inches wc outlet pressure setting, and 2-inches wc droop.<br />

Remote Indicator<br />

Type 803 gives remote visual indication that the supply cylinder is empty<br />

and that the regulator is withdrawing gas from the reserve cylinder. The<br />

indicator has 360° visibility and is weatherproof.<br />

Type 803-61 - Indicator, bracket, screws, and 10-feet (3 meters) of tubing.<br />

Type 803-21 - Indicator only<br />

Type 803-5 - Mounting kit, includes bracket, screws, and 10-feet (3<br />

meters) of tubing.<br />

3<br />

Vent Size<br />

Inches<br />

COMMERCIAL AUTOMATIC CHANGEOVER REGULATORS<br />

Part Number<br />

Part Number<br />

R110-21<br />

R130-21<br />

749B-21<br />

R962-31<br />

Capacity<br />

BTU/HR Propane<br />

64SR-122 1,210,000 1/2 FNPT<br />

1/2 FNPT 10 (0,69)<br />

CHANGEOVER MANIFOLD ASSEMBLIES<br />

R110-21<br />

Capacities in BTU/HR<br />

Propane¹<br />

500,000<br />

1,475,000<br />

1,500,000<br />

1. Capacity based on 100 psig (0,69 bar) inlet.<br />

AUTOMATIC CHANGEOVER REGULATORS<br />

Inlet Connection,<br />

Inches<br />

Inlet Connection,<br />

Inches<br />

1/4 Inverted Flare<br />

1/4 FNPT<br />

1/2 FNPT<br />

803-21<br />

64SR-122<br />

Outlet Connection,<br />

Inches<br />

R130-21 749B-21<br />

Outlet Connection,<br />

Inches<br />

1/4 FNPT<br />

1/4 FNPT<br />

½ FNPT<br />

Outlet Pressure<br />

Setting Psig (bar)<br />

Supply Setting<br />

Psig (bar)<br />

15 (1,03)<br />

45 (3,10)<br />

15 (1,03)<br />

Outlet Pressure Setting<br />

Outlet Adjustment<br />

Range Psig (bar)<br />

5 - 20 (0,34 - 1,38)<br />

Reserve Setting<br />

Psig (bar)<br />

7 (0,48)<br />

30 (2,07)<br />

5 (0,34)