REAL-TIME MONITORING TECHNOLOGY<br />

<strong>For</strong> U.S. <strong>and</strong><br />

<strong>Canada</strong> <strong>Inquiries</strong>:<br />

Phone 800.265.2331<br />

ussales@spectrummedical.com<br />

www.spectrummedical.com<br />

<strong>all</strong> <strong>other</strong> <strong>inquiries</strong>:<br />

Phone +44 (0) 1242.650.120<br />

eusales@spectrummedical.com


eal-time measurement<br />

of critical parameters<br />

high performance<br />

technology with<br />

proven reliability<br />

Spectrum Medical can rightly claim to be the world leader in the measurement<br />

of critical real-time parameters that initiate real-time interventions.<br />

Spectrum Medical is committed to product development <strong>and</strong> innovation <strong>and</strong> to<br />

working with health professionals around the world to improve patient outcomes.<br />

MONITOR SPECIFICATIONS<br />

Model<br />

Code<br />

SaO 2 SvO 2 Hct/Hb<br />

Flow<br />

Channels<br />

Emboli<br />

Detection<br />

M2 ✓ ✓ ✓ – –<br />

M3 ✓ ✓ ✓ Two Two<br />

ZERO CALIBRATION<br />

Immediate access to key parametric data without the need for a blood gas calibration.<br />

SENSOR SPECIFICATIONS<br />

HCT/ SO2<br />

Part Number<br />

3003-010-023<br />

3003-010-024<br />

3003-010-022<br />

3003-010-021<br />

3003-010-025<br />

3003-010-020<br />

Venous Only<br />

Tube ID Tube W<strong>all</strong> Tube OD<br />

3/16<br />

3/16<br />

1/4<br />

1/4<br />

3/8<br />

3/8<br />

1/2<br />

1/16<br />

3/32<br />

1/16<br />

3/32<br />

1/16<br />

3/32<br />

3/32<br />

5/16<br />

3/8<br />

3/8<br />

7/16<br />

1/2<br />

9/16<br />

11/16<br />

Flow Probe<br />

Part Number<br />

H5XLA<br />

N/A<br />

H6XLE<br />

H7XLH<br />

H8XLA<br />

H9XLM<br />

H11XLD<br />

NON–INVASIVE<br />

Improved infection control with reduction in clotting issues <strong>and</strong> the freedom to choose<br />

tubing sets from any supplier.<br />

FLUID MAN<strong>AG</strong>EMENT<br />

Two flow channels, differential flow measurement <strong>and</strong> cardiac index with the ability to<br />

detect <strong>and</strong> analyze channel specific emboli at 1000x/second.<br />

ZERO DRIFT<br />

The knowledge that readings are absolute (rather than trends) with proven dependable<br />

accuracy over both short <strong>and</strong> long-term cases.<br />

PEACE OF MIND<br />

Critical real-time parameters remain accurate during changes in circuit temperature,<br />

hemodilution <strong>and</strong> air ingress events.<br />

USABILITY AND PORTABILITY<br />

System reliability is assured by robust durability <strong>and</strong> high technology engineering. One<br />

minute setup times <strong>and</strong> user-friendly controls on a 10.4” high resolution touch screen<br />

ensure operator ease-of-use.<br />

Light weight <strong>and</strong> flexible with a quick release mounting system <strong>and</strong> a 30-minute<br />

battery life.<br />

COMMUNICATIONS<br />

Wireless, RS - 232, USB, I.R. <strong>and</strong> SD memory card connectivity facilitates data storage,<br />

post operative analysis <strong>and</strong> connection to external electronic charting systems.<br />

PERFUSION DATA COLLECTION<br />

All the benefits of the System M technology can now be integrated with VIPER,<br />

Spectrum Medical’s Data Acquisition software. Combining both Data Collection <strong>and</strong><br />

the Measurement of Critical Parameters into one device significantly improves the user<br />

environment <strong>and</strong> provides for improved patient focus.