Patent Pending<br />

<strong>Street</strong>Sense TM Series LED <strong>Street</strong> <strong>Light</strong>


<strong>Street</strong>Sense TM Series LED <strong>Street</strong> <strong>Light</strong><br />

<strong>Street</strong>Sense LED street lights installed at 35’ mounting height with typical pole spacing of 230’ per side,<br />

staggered array. Read the full story at: www.dialight.com/News/Details/Cape_Girardeau_Case_Study<br />

Precise Optics<br />

<strong>Dialight</strong>’s patent pending reflector based optics provide even light distribution while delivering a sharp back<br />

light cut-off, zero up lighting and reduced glare.<br />

Features & Benefits<br />

w L70 rated for >100,000<br />

hours @ 45°C ambient<br />

w 5 year warranty standard<br />

extended warranty option<br />

available<br />

w LEDs driven at (350mA) for<br />

extended life<br />

w Exceptionally precise optics<br />

(B1,U1,G1 for 60W versions)<br />

full cut-off available<br />

w Field replaceable power supply,<br />

for light engine (consult factory)<br />

w<br />

Up to 76 lm/W<br />

w Significant energy savings<br />

w Instant on/off<br />

w Variable / STEP dimming<br />

available (consult factory)<br />

w Maintenance free<br />

w Mercury free<br />

Easy Installation and Maintenance<br />

w No IR or UV emissions<br />

w Superior light quality<br />

w Built-in thermal overload protection<br />

circuitry provides long term reliability<br />

w Hinged cover provides easy toolless<br />

entry to terminal block and<br />

mounting bracket<br />

w<br />

w<br />

w<br />

w<br />

w<br />

Completely sealed light engine to<br />

provide maximum lumen<br />

maintenance over L70<br />

Resistant to shock and vibration<br />

Superior overall system efficiency<br />

Manufactured in U.S. to meet ARRA<br />

Buy American Requirements<br />

Fixture made of aluminum alloy<br />

A360 for superior strength and<br />

corrosion resistance<br />

Tool-less hinged cover, provides easy access to<br />

terminal block and mounting bracket.<br />

<strong>Dialight</strong>’s <strong>Street</strong>Sense LED <strong>Street</strong> <strong>Light</strong> features a<br />

field replaceable power supply, for field<br />

replaceable light engines consult factory.<br />

2<br />

www.dialight.com


4.8<br />

(122)<br />

<strong>Street</strong>Sense Series<br />

LED <strong>Street</strong> <strong>Light</strong><br />

34.7 (880) 180W<br />

26.5 (674) 120W<br />

18.4 (467) 60W<br />

Mechanical Information<br />

Fixture Weight:<br />

EPA (Sq. ft):<br />

Mounting:<br />

Electrical specifications<br />

Operating Voltage:<br />

16lbs (60W)<br />

25lbs (120W)<br />

34lbs (180W)<br />

0.60 (60W)<br />

0.87 (120W)<br />

1.13 (180W)<br />

Accommodates 1.25”(1.66” OD) - 2” IP<br />

(2.375” OD) pipe. Provision for adjustment of +/-<br />

5° in 2.5° increments<br />

Universal inputs<br />

100-277VAC, 50/60Hz<br />

347-480VAC 50/60Hz<br />

14.7<br />

(372)<br />

Total System<br />

Power Consumption: See ordering info on pg. 4<br />

LED Drive Current:<br />

350mA<br />

Operating Temp 1 :<br />

-40°F to 165°F (-40°C to 74°C) ambient<br />

Certifications and Ratings:<br />

• UL1598 (Suitable for Wet Locations)<br />

• CSA C22.2 No. 250.0-08<br />

• IDA Dark Sky<br />

• ANSI 1012<br />

• UL8750<br />

Compliances:<br />

• RP-8-00 (R2005)<br />

• IEC 60529 (IP 66)<br />

• ANSI C 136.15-2011<br />

Test Reports:<br />

• LM-79 ( pending for IES types IV and V)<br />

• LM-80<br />

Accessories (ordered separately):<br />

• Photo Controller - part number - SLPC01R<br />

• Intelligent street light (consult factory)<br />

• ANSI Label (consult factory)<br />

Dimensions in inches (mm)<br />

Terminal Block:<br />

Noise Requirements /<br />

EMC:<br />

Transient Protection:<br />

THD:<br />

Power Factor: >0.90<br />

Material<br />

Housing:<br />

#14 AWG to #6 AWG wire and accessible<br />

via hinged tool less entry<br />

FCC Title 47, Subpart B, Section 15, class A<br />

device. RF Immunity; 10V/m, 80MHz-1GHz<br />

Open circuit surge protection 6kV standard per<br />

ANSI/IEEE C62.41. 2.2002 cat C low<br />

10kV option consult factory<br />


<strong>Street</strong>Sense Series LED <strong>Street</strong> <strong>Light</strong> Ordering Information<br />

S L - 2 C 4 C L G H<br />

IES Type CCT Voltage Wattage Photocontroller Housing Color 2 Lens<br />

2- II C -6,000K 4 -120-277 C - 60<br />

L - Shorting G - Gray H -Polycarbonate<br />

3-III N -4,300K 7 -347-480 H -120<br />

Cap<br />

G -Glass 3<br />

R -180 N - NPR<br />

4-IV<br />

1<br />

5- V<br />

IES Type II<br />

Total System Power<br />

Initial Fixture<br />

EPA<br />

Part Number<br />

CCT<br />

Lumen Per Watt BUG Rating<br />

Consumption (W)<br />

Lumens<br />

(SQ. ft)<br />

SL2C4CLGH 60 6,000K 4,500 4 75 B1U1G1 0.60<br />

SL2C4HLGH 120 6,000K 9,000 4 75 B2U2G2 0.87<br />

SL2C4RLGH 180 6,000k 13,750 4 76 B3U3G3 1.13<br />

Design <strong>Light</strong>s<br />

Consortium 5<br />

SL2N4CLGH 60 4,300K 4,250 71 B1U1G1 0.60 Yes<br />

SL2N4HLGH 120 4,300K 8,750 73 B2U2G2 0.87<br />

SL2N4RLGH 180 4,300K 13,000 72 B3U3G3 1.13<br />

IES Type III<br />

Total System Power<br />

Initial Fixture<br />

EPA Design <strong>Light</strong>s<br />

Part Number<br />

CCT<br />

Lumen Per Watt BUG Rating<br />

Consumption (W)<br />

Lumens<br />

(SQ. ft) Consortium 5<br />

SL3C4CLGH 60 6,000K 4,500 75 B1U2G1 0.60 Yes<br />

SL3C4HLGH 120 6,000K 9,000 75 B2U2G2 0.87 Yes<br />

SL3C4RLGH 180 6,000k 13,750 76 B3U3G3 1.13 Yes<br />

SL3N4CLGH 60 4,300K 4,000 67 B1U1G1 0.60 Yes<br />

SL3N4HLGH 120 4,300K 8,000 67 B2U2G2 0.87 Yes<br />

SL3N4RLGH 180 4,300K 12,250 68 B3U3G3 1.13<br />

IES Type IV<br />

Total System Power<br />

Initial Fixture<br />

Part Number<br />

CCT<br />

Lumen Per Watt BUG Rating EPA (SQ. ft)<br />

Consumption (W)<br />

Lumens<br />

SL4C4CLGH 60 6,000K 4,250 4 71 B1U2G1 0.60<br />

SL4C4HLGH 120 6,000K 8,750 4 73 B2U3G2 0.87<br />

SL4C4RLGH 180 6,000K 13,000 4 72 B3U3G3 1.13<br />

SL4N4CLGH 60 4,300K 4,000 4 67 B1U2G1 0.60<br />

SL4N4HLGH 120 4,300K 8,000 4 67 B2U3G2 0.87<br />

SL4N4RLGH 180 4,300K 12,000 4 67 B3U3G3 1.13<br />

IES Type V<br />

Total System Power<br />

Initial Fixture<br />

EPA<br />

Part Number<br />

CCT<br />

Lumen Per Watt BUG Rating<br />

Consumption (W)<br />

Lumens<br />

(SQ. ft)<br />

SL5C4CLGH 60 6,000K 4,250 4 71 B2U2G2 0.60<br />

SL5C4HLGH 120 6,000K 8,500 4 73 B3U3G3 0.87<br />

SL5C4RLGH 180 6,000k 12,500 4 72 B3U3G3 1.13<br />

SL5N4CLGH 60 4,300K 4,000 4 67 B2U2G2 0.60<br />

SL5N4HLGH 120 4,300K 8,000 4 67 B3U3G3 0.87<br />

SL5N4RLGH 180 4,300K 12,000 4 67 B3U3G3 1.13<br />

1<br />

No photocontrol receptacle (NPR) option consult factory<br />

2<br />

White, black, bronze and green color options available, consult factory, extended lead times apply<br />

3 Glass lens option will increase lumen values by 8%<br />

4<br />

Lumen values based on preliminary IES files. LM-79 pending.<br />

5 <strong>Dialight</strong> part numbers qualified by Design <strong>Light</strong>s Consortium under requirements ver. 1.5 (6,000k), DLC listing valid till 04/2012. Future <strong>Street</strong>Sense products will be listed under<br />

ver. 1.6 (5300K)<br />

4<br />

www.dialight.com


IES Type II - Measurement Data 1<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 25 ft Mounting Height<br />

60 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

Intensity Distribution Curve (cd)<br />

0.01<br />

0.2 0.4 1<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

10 6.250<br />

15 2.228<br />

20 1.563<br />

25 1.000<br />

30 0.694<br />

35 0.510<br />

40 0.391<br />

45 0.309<br />

50 0.250<br />

ETL Intertek certified test performed to IES LM-79-08 standards<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 30 ft Mounting Height<br />

0.07 0.14 0.3 0.7 1.4<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 40 ft Mounting Height<br />

120 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

10 9.000<br />

15 4.000<br />

20 2.250<br />

25 1.440<br />

30 1.000<br />

35 0.735<br />

40 0.503<br />

45 0.444<br />

50 0.360<br />

180 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

Intensity Distribution Curve (cd)<br />

Intensity Distribution Curve (cd)<br />

.8<br />

0.04 0.1 0.15 0.4 1.5<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

10 16.000<br />

15 7.111<br />

20 4.000<br />

25 2.560<br />

30 1.778<br />

35 1.306<br />

40 1.000<br />

45 0.790<br />

50 0.640<br />

1<br />

Cool white values shown – neutral white versions ≈ 6% lower<br />

www.dialight.com<br />

5


IES Type III - Measurement Data 1<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 25 ft Mounting Height<br />

0.1<br />

2.<br />

0.4<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

0.2<br />

60 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

10 6.250<br />

15 2.228<br />

20 1.563<br />

25 1.000<br />

30 0.694<br />

35 0.510<br />

40 0.391<br />

45 0.309<br />

50 0.250<br />

Intensity Distribution Curve (cd)<br />

ETL Intertek certified test performed to IES LM-79-08 standards<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 30 ft Mounting Height<br />

0.07 0.1<br />

0.3<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

120 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

10 9.000<br />

15 4.000<br />

20 2.250<br />

25 1.440<br />

30 1.000<br />

35 0.735<br />

40 0.503<br />

45 0.444<br />

50 0.360<br />

Intensity Distribution Curve (cd)<br />

ETL Intertek certified test performed to IES LM-79-08 standards<br />

0.7<br />

1.4<br />

0.04<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 40 ft Mounting Height<br />

1.5<br />

.8<br />

0.15<br />

0.08<br />

0.4<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

180 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

10 16.000<br />

15 7.111<br />

20 4.000<br />

25 2.560<br />

30 1.778<br />

35 1.306<br />

40 1.000<br />

45 0.790<br />

50 0.640<br />

Intensity Distribution Curve (cd)<br />

ETL Intertek certified test performed to IES LM-79-08 standards<br />

1<br />

Cool white values shown – neutral white versions ≈ 6% lower<br />

6<br />

www.dialight.com


IES Type IV - Measurement Data 1<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 25 ft Mounting Height<br />

0.01<br />

0.2<br />

0.4<br />

1.<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 30 ft Mounting Height<br />

0.7<br />

1.4<br />

0.14<br />

0.3 0.07<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 40 ft Mounting Height<br />

0.4 0.15 0.08 0.04<br />

.6<br />

1.5<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

60 Watt<br />

Mounting<br />

Height<br />

120 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

10 9.000<br />

15 4.000<br />

20 2.250<br />

25 1.440<br />

30 1.000<br />

35 0.735<br />

40 0.503<br />

45 0.444<br />

50 0.360<br />

180 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

10 6.250<br />

15 2.228<br />

20 1.563<br />

25 1.000<br />

30 0.694<br />

35 0.510<br />

40 0.391<br />

45 0.309<br />

50 0.250<br />

Multiplier<br />

10 16.000<br />

15 7.111<br />

20 4.000<br />

25 2.560<br />

30 1.778<br />

35 1.306<br />

40 1.000<br />

45 0.790<br />

50 0.640<br />

Intensity Distribution Curve (cd)<br />

Intensity Distribution Curve (cd)<br />

Intensity Distribution Curve (cd)<br />

1<br />

Cool white values shown – neutral white versions ≈ 6% lower<br />

7


IES Type V - Measurement Data 1<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 25 ft Mounting Height<br />

60 Watt<br />

Mounting<br />

Height<br />

Multiplier<br />

Intensity Distribution Curve (cd)<br />

0.1<br />

2.<br />

0.4<br />

0.2<br />

10 6.250<br />

15 2.228<br />

20 1.563<br />

25 1.000<br />

30 0.694<br />

35 0.510<br />

40 0.391<br />

45 0.309<br />

50 0.250<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

120 Watt<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 30 ft Mounting Height<br />

Intensity Distribution Curve (cd)<br />

0.1<br />

2. 0.27<br />

0.7<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

Iso-Illuminance Chart (fc)<br />

Example shown: 40 ft Mounting Height<br />

3.<br />

Mounting<br />

Height<br />

Multiplier<br />

10 9.000<br />

15 4.000<br />

20 2.250<br />

25 1.440<br />

30 1.000<br />

35 0.735<br />

40 0.503<br />

45 0.444<br />

50 0.360<br />

180 Watt<br />

Intensity Distribution Curve (cd)<br />

Mounting<br />

Height<br />

Multiplier<br />

1.5<br />

.8<br />

0.4<br />

0.15<br />

Spacing of each box is equal to mounting height in feet.<br />

Ex: 40ft mounting height = each box is 40ft, 30ft mounting height = each box is 30ft<br />

- Location of streetlight<br />

1<br />

Cool white values shown – neutral white versions ≈ 6% lower<br />

10 16.000<br />

15 7.111<br />

20 4.000<br />

25 2.560<br />

30 1.778<br />

35 1.306<br />

40 1.000<br />

45 0.790<br />

50 0.640<br />

<strong>Dialight</strong> reserves the right to make changes at any time in order to supply the best product possible.<br />

The most current version of this document will always be available at:<br />

www.dialight.com/Assets/Brochures_And_Catalogs/Illumination/<strong>MDTFSL3X001</strong>.pdf<br />

www.dialight.com<br />

<strong>MDTFSL3X001</strong>_D

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!