<strong>Capillary</strong> <strong>Column</strong> <strong>Cutters</strong><br />

Cutting Edge Technologies<br />

Shortix TM<br />

With rotating diamond blade<br />

Features<br />

• Leak-tight Quick-Fit connections<br />

• Trouble free Preparations for On-<br />

<strong>Column</strong> Injections<br />

• Improved Reproducibility of Split<br />

and Splitless Injections<br />

• Improved Reproducibility of<br />

Analytical Results<br />

• A perfect reproducible cut independent<br />

from skill & experience<br />

rev. 1.0<br />

EP-B-1021381 U.S. Patent US-A-6,708,857


Shortix TM <strong>Capillary</strong> <strong>Column</strong> <strong>Cutters</strong><br />

Gas chromatographic and column techniques, like On-<strong>Column</strong> injecton, Quick-Fit column connectons or any other critcal<br />

gas chromatographic analysis, make it a necessity to cut a column extremely straight without cracked column walls or column<br />

blockage because of fused-silica partcles. The Shortx TM <strong>Capillary</strong> <strong>Column</strong> Cutter is especially designed to allow everybody,<br />

independent from skill and experience level, to make the perfect cut. This is important because these errors, caused by non<br />

perfect column cuts, will result in poor chromatography, spikes in the chromatogram, leaking Quick-Fit connectons, bad<br />

chromatographic reproducibility of retenton tmes and peak broadening.<br />

When traditonal column cutters, like a diamond pen or a sapphire, are used, only a fracton of the column wall is<br />

scratched. The column is then broken off resultng in a partly cracked, thus damaged, column wall. The SGT Shortx<br />

<strong>Capillary</strong> <strong>Column</strong> Cutter rotates a diamond cutter around the whole column wall making a scratch all the way<br />

around the wall. The column is then broken off resultng in a perfectly straight column cut.<br />

Shortix GC<br />

Catalog No.<br />

Specifications<br />

S0010<br />

Usable For Fused Silica <strong>Capillary</strong> <strong>Column</strong> Ø 0.5<br />

Use with 0.25mm ID to 0.53mm ID<br />

tubing (0.78mm OD maximum).<br />

Dimensions<br />

Weight<br />

9.2 cm x 1.7 cm x 1.7 cm<br />

94 g<br />

Shortix TM GC<br />

In Gas chromatography, the Glass<br />

Quick-Fit connecton is often used.<br />

(e.g. for Retenton Gaps, Guard<br />

<strong>Column</strong>s) This connecton will only<br />

be leak-tght when the column is cut<br />

extremely straight and without any<br />

damage to the fused-silica column<br />

wall.<br />

Shortix CE-CEC<br />

Catalog No.<br />

Specifications<br />

Usable For<br />

Dimensions<br />

Weight<br />

S0020<br />

Fused Silica <strong>Capillary</strong> <strong>Column</strong> Ø<br />

0.25micron<br />

9.7 cm x 1.7 cm x 1.7 cm<br />

94 g<br />

Shortix TM CE-CEC<br />

For CE/CEC analyses a clean and<br />

straight cut of the capillary column<br />

is needed to assure symetrical<br />

Field-Strength over the inlet of the<br />

column. When there is no symetrical<br />

Field-Strength, the analytcal results<br />

will be non-reproducable.<br />

Shortix Plus<br />

Catalog No.<br />

Specifications<br />

Usable For<br />

Tools Included<br />

S0040<br />

Fused Silica <strong>Capillary</strong> <strong>Column</strong> Ø 0.5 Use<br />

with 0.25mm ID to 0.53mm ID tubing<br />

(0.78mm OD maximum).<br />

Shortx Diamond <strong>Column</strong> Cutter, a<br />

septum hook, an universal wrench,<br />

a ferrule remover, a round file, can<br />

opener, blade, scissors, tweezers,<br />

toothpick etc.<br />

Shortix TM Plus<br />

Shortx Plus offers the mostly used<br />

lab tools, like the Shortx Diamond<br />

<strong>Column</strong> Cutter, a septum hook, an<br />

universal wrench, a ferrule remover<br />

and a round file.<br />

Shortx Plus also contains a variety<br />

of regularly used<br />

standard knife items like a can<br />

opener, blade, scissors, tweezers,<br />

toothpick etc.<br />

Extended toolkit featuring ferrule<br />

reemers, burner tp cleaner, liner<br />

remover etc.<br />

Page 2


Fix-It<br />

Catalog No.<br />

Specifications<br />

Tools Included<br />

S0050<br />

GC injectonport liner remover, special<br />

cassette with 3 tools : (round file –<br />

ferrule remover – septum remover),<br />

magnifying glass (20 x), bottle opener,<br />

can opener, wrench,Philips universal<br />

screw driver, pliers, knife blade, pair<br />

of scissors,corkscrew,tweezers and a<br />

tooth pick<br />

Fix - It<br />

The Fix It ® swiss army knife<br />

pocket knife for the laboratory<br />

features 15 handy<br />

tools for use in the lab.<br />

Ordering Information<br />

Shortix TM Diamond <strong>Capillary</strong> <strong>Column</strong> Cutter for GC<br />

Part No. Description qty.<br />

S0010<br />

SGT Shortx TM GC<br />

Includes Standard -Black Fused Silica <strong>Capillary</strong> <strong>Column</strong> Cutter for <strong>Capillary</strong><br />

GC <strong>Column</strong>s<br />

ea.<br />

Shortix TM Diamond <strong>Capillary</strong> <strong>Column</strong> Cutter for CE-CEC<br />

Part No. Description qty.<br />

S0020<br />

SGT Shortx TM CE-CEC<br />

Includes Standard -Blue Fused Silica <strong>Capillary</strong> <strong>Column</strong> Cutter for <strong>Capillary</strong><br />

CE/CEC <strong>Column</strong>s<br />

ea.<br />

Shortix TM Plus Diamond <strong>Capillary</strong> <strong>Column</strong> Cutter for GC<br />

Part No. Description qty.<br />

S0040<br />

SGT Shortx TM Plus GC<br />

Includes Genuine Swiss Army Lab Knife with built in Fused Silica <strong>Capillary</strong><br />

<strong>Column</strong> Cutter for <strong>Capillary</strong> GC <strong>Column</strong>s<br />

ea.<br />

Page 3


Fix-It<br />

Part No. Description qty.<br />

S0050<br />

Fix-It<br />

Fix It ® swiss army knife pocket knife for the laboratory<br />

ea.<br />

Maintenance Kit for Shortix TM GC<br />

Part No. Description qty.<br />

S0011<br />

Maintenance Kit for Shortx TM GC<br />

Includes diamond cutting wheel, O-rings, and a tool to open the column<br />

cutter<br />

ea.<br />

Maintenance Kit for Shortix TM CE-CEC<br />

Part No. Description qty.<br />

S0021<br />

Maintenance Kit for Shortx TM CE-CEC<br />

Includes diamond cutting wheel, O-rings, and a tool to open the column<br />

cutter<br />

ea.<br />

Authorised Reseller<br />