drawings

freeplotting.com

drawings

1 2 3 4 5 6

NO.

TITLE

REVISIONS

E

TANGER OUTLET CENTER, SANIBEL (FACTORY)

20350 SUMMERLIN ROAD, SUITE 8115

FORT MYERS, FL 33908

J oS. A. BANK

ARCHITECTURAL

G-001 TITLE SHEET

G-002 RESPONSIBILITY SCHEDULE & PRE-CONSTRUCTION NOTES

G-003 GENERAL SPECIFICATIONS

G-004 GENERAL SPECIFICATIONS & LANDLORD GENERAL NOTES

AD-110 DEMOLITION FLOOR PLAN

A-109 FIRE LIFE SAFETY PLAN

A-110 FLOOR PLAN

A-111 FLOOR FINISH PLAN

A-120 REFLECTED CEILING PLAN

A-201 EXTERIOR ELEVATION & ENLARGED PLAN

A-202 EXTERIOR ELEVATION & ENLARGED PLAN

A-203 EXTERIOR ELEVATION & ENLARGED PLAN

A-204 STOREFRONT DETAILS

A-401 INTERIOR ELEVATIONS

A-402 PARTIAL PLANS & INTERIOR ELEVATIONS

A-501 ARCHITECTURAL DETAILS

A-601 DOOR SCHEDULE & NOTES

A-602 FINISH SCHEDULE

A

A

A

A

A

A

A

E

Calvin J.

Coatsworth, AIA

Irvine,

Phone:

Fax:

2495 Campus Drive

Second Floor

California 92612

949. 833. 1930

949. 833. 1140

D

1. THE BID, AND ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL LOCAL AND STATE BUILDING CODES,

ORDINANCES & BUILDING INSPECTIONS AND BE ENFORCED BY THE CONTRACTORS AT ALL TIMES.

2. GENERAL CONTRACTOR (G.C.) AND ALL SUB-CONTRACTORS SHALL PROVIDE EVIDENCE OF WORKMAN'S

COMPENSATION UPON SUBMITTING BID. UPON AWARD OF CONTRACT, CONTRACTOR SHALL SHOW EVIDENCE THAT THE

TENANT IS NAMED AS AN ADDITIONAL INSURED.

3. BY SUBMITTING A BID, G.C. ASSERTS THAT HE IS FAMILIAR W/ THE SITE, ALL EXIST. CONDITIONS & THE TENANT

HANDBOOK (IF ANY).

4. G.C. SHALL PROVIDE ALL FLOOR LEVELING, PATCHING, AND REMEDIAL REPAIRS AS REASONABLY REQUIRED BY THE

SCOPE OF WORK. "REPAIRS" INCLUDE, BUT ARE NOT LIMITED TO, WORK REQUIRED TO PROVIDE A SMOOTH AND EVEN

TRANSITION BETWEEN NEW AND EXIST. SPACES, AND TO PREPARE EXIST. SURFACES FOR NEW FINISHES.

5. DIMENSIONS ON PLANS ARE TO CENTER LINE OF COLUMNS AND FACE OF FINISH.

6. JOB SITE IS TO BE KEPT CLEAN DURING CONSTRUCTION. G.C. SHALL PERIODICALLY AND PROMPTLY REMOVE ALL

DEBRIS FROM SITE AT HIS EXPENSE IN LEGAL MANNER.

7. G.C. SHALL VERIFY BUILDING DEPARTMENT PROCEDURE FOR OBTAINING ALL PERMITS PRIOR TO SUBMITTING BIDS.

CONTRACTOR SHALL PAY FOR ALL NECESSARY PERMITS AND / OR FEES REQUIRED BY PUBLIC AUTHORITIES AND / OR

UTILITY COMPANIES AND PAY ALL TEMPORARY POWER COSTS. ANY TIE-IN OR INSPECTION FEES TO BE INCLUDED IN

BID. CONTRACTOR TO VERIFY IF WATER OR OTHER METERS ARE REQUIRED BY LANDLORD, OR UTILITY, AND ARE

INCLUDED IN BID.

8. ALL WORK SHOWN ON THESE DRAWINGS IS TO BE PERFORMED BY THE G.C. UNLESS NOTED OTHERWISE.

D

C5

A-202

A1

A-201

A

D1

C

D4

A-702

GRID

B

SECTION NUMBER

SHEET NUMBER

ELEVATION

SHEET NUMBER

ELEVATION

REFERENCE DWG. NO.

DETAIL NUMBER

SHEET NUMBER

COLUMN GRID MARK

BUILDING

ELECTRICAL

MECHANICAL

PLUMBING

FIRE/LIFE SAFETY

ACCESSIBILITY

ENERGY

CATEGORY

OCCUPANCY GROUP

OCCUPANT LOAD

APPLICABLE CODES

2007 FLORIDA BUILDING CODE WITH 2009

SUPPLEMENTS

2008 NATIONAL ELECTRICAL CODE (NFPA 70)

2007 FLORIDA MECHANICAL CODE WITH

2009 SUPPLEMENTS

2007 FLORIDA PLUMBING CODE WITH 2009

SUPPLEMENTS

2007 FIRE PREVENTION CODE WITH FLORIDA

AMENDMENTS

2007 FLORIDA ACCESSIBILITY CODE WITH

2009 SUPPLEMENTS, CHAPTER 11

2007 FLORIDA BUILDING CODE WITH 2009

SUPPLEMENTS

REQUIREMENTS

STATUS/REQUIREMENTS

M

30 SF PER PERSON AT SALES / 300 SF AT

STOCK

CLIENT / TENANT

NAME

ADDRESS

CONTACT

PHONE

FAX

CELL

NAME

ADDRESS

CONTACT

PHONE

FAX

JoS. A. BANK CLOTHIERS, INC.

500 HANOVER PIKE

HAMPSTEAD, MD 21074

PROJECT MANAGER

JEFF HANUSIN

(443) 508-4888

(443) 508-4799

(443) 567-1415

ARCHITECT OF RECORD

CALVIN J. COATSWORTH, AIA

2495 CAMPUS DRIVE

2ND FLOOR

IRVINE, CA 92612

CALVIN J. COATSWORTH

(949) 833-1930

(949) 833-1140

PROJECT COORDINATOR

BRENDA CHRONISTER

(443) 508-4750

(443) 508-4799

M-110

M-501

M-601

MECHANICAL

HVAC PLAN

HVAC DETAILS

HVAC SPECIFICATIONS

D

FILE LOCATION: p:\2011\11164\Sheets\G-001.dwg PLOT DATE: 10/27/2011 2:51 PM

C

B

A

9. G.C. SHALL USE ONLY EXPERIENCED CRAFTSMEN SKILLED IN THE DUTIES WHICH THEY ARE TO PERFORM ON THIS

PROJECT.

10. G.C. SHALL COORDINATE CONSTRUCTION SCHEDULE WITH LANDLORD'S SITE REPRESENTATIVE.

11. DURING CONSTRUCTION, G.C. SHALL PROVIDE AND MAINTAIN FIRE EXTINGUISHERS AS REQ'D. BY THE LOCAL FIRE DEPT.

FIELD INSPECTOR.

12. PRIOR TO COMPLETION OF CONSTRUCTION G.C. SHALL PROVIDE & HANG FIRE EXTINGUISHER(S) AND MISC. ITEMS PER

TENANT'S OPERATIONS DEPT. OR AS DIRECTED BY LOCAL BUILDING INSPECTORS.

13. WHERE NEW CONSTRUCTION IS TO BE SUSPENDED FROM THE EXISTING STRUCTURE, G.C. SHALL FIRST VERIFY THAT

THE EXISTING STRUCTURE HAS THE CAPACITY TO SUPPORT SUCH NEW ASSEMBLIES. REPORT INADEQUATE STRUCTURE

TO ARCHITECT.

14. PROVIDE AND/OR MAINTAIN FIRE RATED ASSEMBLIES WHERE SHOWN, OR REQUIRED.

15. ANY ROOF PENETRATIONS SHALL BE APPROVED IN WRITING BY THE LANDLORD. IN THE EVENT THE LANDLORD REQUIRES

THE PENETRATIONS TO BE MADE BY THE LANDLORD'S CONTRACTOR, THE G.C. SHALL BEAR SUCH EXPENSE UNLESS

OTHERWISE AGREED TO IN WRITING. ROOF PENETRATIONS MUST BE BY LANDLORD'S ROOFING CONTRACTOR.

16. G.C. SHALL REPORT EXACT TOTAL SQUARE FOOTAGE OF LEASE SPACE & A DIAGRAM OF TENANT LEASE LINE

BOUNDARY WITH DIMENSIONS, TO TENANT WITHIN SEVEN (7) DAYS OF COMMENCING WORK.

17. G.C. SHALL PROVIDE AND MAINTAIN CELL PHONE SERVICE AT THE JOB SITE THROUGHOUT CONSTRUCTION PERIOD.

18. G.C. SHALL PROVIDE PEDESTRIAN PROTECTION BARRICADES AND/OR CANOPIES AS REQUIRED BY THE LOCAL

AUTHORITIES OR AS NECESSARY FOR PEDESTRIAN SAFETY.

19. G.C. SHALL VERIFY WITH LANDLORD REQUIREMENTS TO TIE INTO MALL FIRE ALARM SYSTEM (SMOKE EVACT. SYSTEM IF

REQUIRED) AND DETERMINE WHO IS TO FURNISH ALL REQUIRED EQUIPMENT. ALL CONTRACTOR COSTS ARE TO BE

COVERED IN BID.

20. ALL SPRINKLER WORK MODIFICATIONS SHALL BE COORDINATED WITH ALL OTHER TRADES ON SITE. G.C. IS

RESPONSIBLE FOR ALL SPRINKLER WORK, ENGINEERING, HYDRAULIC CALCULATIONS AND PERMITS FOR ALL UPGRADES

AND MODIFICATIONS, INCLUDING ALL RISERS AND HEADS. ALL SPRINKLER WORK SHALL ACCOMMODATE TENANT

IMPROVEMENTS PER APPROVED CONSTRUCTION DRAWINGS AND SPECIFICATIONS.

21. G.C. IS RESPONSIBLE TO PROVIDE AND INSTALL ANY AND ALL ACCESS PANELS AS REQUIRED.

22. G.C. SHALL COORDINATE THE RETURN OF ALL SURPLUS JOS. A. BANK'S PROVIDED MATERIALS, PER TENANT

REPRESENTATIVE'S INSTRUCTIONS.

23. ABSOLUTELY NO ASBESTOS OR ASBESTOS CONTAINING MATERIALS (ACM) SHALL BE USED IN THE CONSTRUCTION OF

THIS PROJECT. G.C. SHALL NOTIFY ARCHITECT OF MATERIALS SUSPECTED TO BE A.C.M.

24. G.C. SHALL BE RESPONSIBLE TO RECEIVE AND INVENTORY JOS. A. BANK SUPPLIED CONSTRUCTION ITEMS. G.C. SHALL

BE RESPONSIBLE FOR THE PROVISION AND PROTECTION OF ALL MATERIALS AND FIXTURES ON THE JOB SITE.

CONTRACTOR SHALL ACCOUNT FOR ALL MATERIALS SHIPPED TO JOB SITE. IF ANY MATERIALS ARRIVE ON JOB SITE

DAMAGED, G.C. SHALL NOTE ON BILL OF MATERIALS AND NOTIFY CARRIER OFFICE THAT THEY NEED TO INSPECT

DAMAGE. FAILURE TO DO SO SHALL HOLD G.C. RESPONSIBLE.

25. ALL REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT & ANY LOCAL ACCESSIBILITY CODES SHALL BE

ADHERED TO WHEN IN CONFLICT, THE MORE STRINGENT OF THE TWO STANDARDS SHALL GOVERN.

26. G.C. SHALL USE GYPSUM BOARD OF THICKNESS NOTED AND WITH TAPERED EDGES. ALL OUTSIDE CORNERS SHALL

HAVE METAL SCREED, CASING BEADS OR CORNER BEADS AS REQUIRED. TAPE ALL JOINTS, BED AND SAND SMOOTH

IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SMOOTH SURFACE TO RECEIVE PAINT.

SCREW GYPSUM BOARD TO BACKING.

27. ALL CONDITIONS DESCRIBED IN GEN. NOTES SHALL BE INCLUDED IN BID.

28. INSTALL ALL WORK WITH APPROVED FASTENERS, AS REQUIRED TO HOLD WORK SECURE, LEVEL, PLUMB AND TRUE TO

LINE. FASTENERS TO BE SET BELOW THE FINISHED SURFACES, FILL HOLES WITH WOOD PUTTY OR OTHER APPROVED

MATERIAL, SAND FLUSH WITH THE SURFACE SO AS TO BE UNDETECTABLE IN THE FINISH. BLIND NAIL WHENEVER

POSSIBLE. ROUND ALL EXPOSED EDGES OF ASSEMBLIES TO 1/8" RADIUS.

29. ALL EXPOSED WOODWORK TO RECEIVE PAINT FINISH SHALL BE SANDED SMOOTH PRIOR TO FINISHING WITH SAND

PAPER. NO COARSER THAN NO. 80. FILL OPEN JOINTS AND SAND SMOOTH AND FLUSH.

30. PROVIDE ALL NECESSARY SHIMS AND FILLERS. CONCEAL ALL FASTENERS UNLESS OTHERWISE NOTED.

31. ALL PAINT, PRIMERS AND SEALERS TO BE SUPPLIED WITH LABOR.

32. SURFACES TO RECEIVE PAINT SHALL BE PAINTED ONE PRIMER COAT AND ONE FINISH COAT (MINIMUM) PLUS

TOUCH-UP.

33. WOOD PRODUCTS AND FINISHES SHALL MEET FLAME SPREAD AND SMOKE GENERATION REGULATIONS.

34. CONSTRUCTION TO BE IN ACCORDANCE WITH FINAL PLANS APPROVED BY THE LANDLORD, LOCAL, STATE AND FEDERAL

CODES.

35. ALL STRUCTURAL MEMBERS NOT SHOWN ARE TO REMAIN.

36. ALL CONDITIONS AND DIMENSIONS ARE TO BE VERIFIED IN THE FIELD. ALL NOTES, DIMENSIONS AND FINISHES ARE

SUBJECT TO APPROVAL OF TENANT REPRESENTATIVE.

37. NO STRUCTURAL CHANGES ARE REQUIRED WITH THESE ALTERATIONS.

38. INTERIOR FINISH OF STORE TO HAVE A FLAME SPREAD RATING OF 25 OR LESS.

39. POST A "NO SMOKING" SIGN IN WORKROOM.

40. LOCATION OF FIRE EXTINGUISHERS AS DIRECTED BY FIRE MARSHALL.

41. ALL WOOD AND PLYWOOD TO BE FIRE-TREATED.

42. G.C. SHALL COMPLY WITH ALL REQUIREMENTS OF ADA AND/OR LOCAL H.C. CODES TO BE INCLUDED IN BID PRICE.

43. G.C. IS REQUIRED TO VISIT THE SITE PRIOR TO CONSTRUCTION AND NOTIFY THE ARCHITECT AND OWNER IMMEDIATELY

OF ANY CONDITIONS WHICH MAY CONFLICT WITH THE PROPOSED DESIGN.

44. THE G.C. SHALL COORDINATE WITH THE TENANT'S VENDORS AS REQUIRED TO INCORPORATE TENANT PROVIDED ITEMS.

45. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LANDLORD'S STANDARD CONSTRUCTION CRITERIA.

46. THE G.C. SHALL PROVIDE THE ARCHITECT WITH A COPY OF THE BUILDING & SAFETY APPROVED CONSTRUCTION

DOCUMENTS AT THE TIME PERMIT IS ISSUED. IN THE EVENT THAT THE DRAWINGS ARE "APPROVED AS NOTED", THE

ARCHITECT WILL INCORPORATE COMMENTS INTO A CONSTRUCTION ISSUE SET.

GENERAL NOTES

9'-0"

1

1

VCT

1

SALES

AREA

001

11

1

0'-0"

FINISH MATERIAL

FINISH NUMBER

SYMBOLS LEGEND

J oS. A. BANK

TANGER OUTLET CENTER,

SUITE 8115

KEY PLAN

MCGREGOR BOULEVARD

SUMMERLIN RD.

CEILING HEIGHT

DOOR SCHEDULE NUMBER

PARTITION TYPE, SEE FLOOR

PLAN FOR WALL TYPES

FINISH DESIGNATION SEE

FINISH SCHEDULE

ROOM NAME AND NUMBER

CEILING GRID

STARTING POINT

MATERIAL FINISH / BREAK

LINE OF SOFFIT OR

ELEMENT ABOVE

TENANTS LEASE LINE

CENTER LINE

WALL TO REMAIN

OR PARTIAL HEIGHT

NEW PARTITION WALL

NEW RATED PARTITION

AREA TO BE PATCHED

OR LEVELED

REVISION

PARTITION / DOOR

TO BE DEMOLISHED

KEY NOTE

CONSTRUCTION TYPE

HEIGHT LIMITATION

AREA LIMITATION

EXTERIOR WALLS / BEARING

FIRE/PARTY WALLS

FIRE SEPARATION ASSEMBLY

EXIT CORRIDOR

TENANT SEPARATION

SPRINKLER SYSTEM

EGRESS WIDTH (DOOR)

EGRESS WIDTH (STAIRWAYS)

MAX. EXIT ACCESS

MIN. AISLE WIDTH

SCOPE OF WORK:

CONSTRUCTION OF NEW TENANT IMPROVEMENT IN ONE EXISTING SHELL SPACE

ROOM NAME

SALES AREA

TAILORING/PRESS AREA

FITTING AREA

TOILET ROOM

DISPLAY

TOTAL

CODE ANALYSIS

FIRE ALARM:

EXTEND OR MODIFY FIRE ALARM AS NEEDED.

FIRE SPRINKLER SYSTEM:

AN AUTOMATIC FIRE SPRINKLER SYSTEM IS EXISTING WITHIN THIS SPACE.

CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM AS REQUIRED FOR THE

NEW SPACE CONFIGURATION AND CEILING HEIGHTS. MODIFICATIONS SHALL BE

DESIGNED AND INSTALLED BY A QUALIFIED LICENSED FIRE SPRINKLER CONTRACTOR,

WHO SHALL PREPARE DESIGN / SHOP DRAWINGS OF THE SYSTEM AND SUBMIT

SUCH DRAWINGS TO THE LANDLORD, BUILDING AND FIRE DEPARTMENTS FOR

APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK SHALL BE DONE

IN ACCORDANCE WITH NFPA, STANDARD 101 AND ANY OTHER STATE OR LOCAL

CODES HAVING JURISDICTION

EXIT ILLUMINATION:

EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED AS SHOWN ON ELECTRIAL

DRAWINGS

FIRE DEPARTMENT NOTES

SHELL POINT BLVD.

TANGER OUTLET

CENTER

VICINITY MAP

PROJECT TABULATIONS

346 S.F.

154 S.F.

44" MIN. CLEAR

36" & 44" MIN. CLEAR

2,426 S.F.

403 S.F.

TYPE-IIB / FULLY SPRINKLERED

EXISTING

EXISTING

N/A

N/A

N/A

N/A

1 HOUR

EXISTING

32" MIN. CLEAR

250'

SQ. FOOTAGE

0 S.F. N/A

3,329 S.F.

LOAD FACTOR

1:30

1:300

N/A

N/A

MCGREGOR BOULEVARD

SUMMERLIN RD.

AMAZON LN.

LOAD SUMMARY

2,426 / 30 = 81

403 / 300 = 2

0 (ACCESSORY USE)

0 (ACCESSORY USE)

0 (ACCESSORY USE)

83 OCCUPANTS

ARBOR RIDGE DR.

S. OLEANDER DR.

JACARANDA DR.

POINT BREEZE DR.

KELLY SANDS WAY

JOHN MORRIS RD.

ARCHITECTURAL PROJECT MANAGER

NAME

ADDRESS

CONTACT

PHONE

FAX

NAME

ADDRESS

CONTACT

PHONE

FAX

NAME

ADDRESS

CONTACT

PHONE

FAX

NAME

ADDRESS

CONTACT

PHONE

FAX

CARLILE COATSWORTH ARCHITECTS

2495 CAMPUS DRIVE

2ND FLOOR

IRVINE, CA 92612

ALLISON WALKER

(949) 833-1930 X 1145

(949) 833-1140

MECHANICAL, PLUMBING AND ELECTRICAL

ENGINEER

SCHNACKEL ENGINEERS, INC.

3035 S. 72nd STREET

OMAHA, NE 68124

NICK MANNING

(402) 391-7680

(402) 391-7488

LANDLORD / TENANT COORDINATOR

TANGER OUTLET CENTERS

873 FOX MEADOW ROAD

CHAMBERSBURG, PA 17201

KATE DOUGHERTY

(717) 261-1117

(336) 292-0416

BUILDING DEPARTMENT

FIRE DEPARTMENT

NAME

ADDRESS

CONTACT

PHONE

FAX

LEE COUNTY COMMUNITY DEVELOPMENT

BUILDING SERVICES

1500 MONROE STREET

FORT MYERS, FL 33901

SHARON REYNOLDS

(239) 533-8329

(239) 485-8529

PROJECT DIRECTORY

SIGNAGE

NAME

ADDRESS

CONTACT

PHONE

LIGHT FIXTURES

NAME

ADDRESS

CONTACT

PHONE

HVAC UNITS

NAME

ADDRESS

CONTACT

PHONE

AWNING & SIGN CONTRACTORS

203 WEST HARCOURT ROAD

ANGOLA, IN 46703

RON ZUCCATO

(856) 294-9008

CAPITOL LIGHT

1508 SNOWBERRY DRIVE

WILLIAMSTOWN, NJ 08094

DENISE LENGEMANN

(856) 629-3919

CARRIER NATIONAL ACCOUNTS

6304 CARRIER PARKWAY

SYRACUSE, NY 13221

BRIDGETTE MELFI

(315) 432-6585

TENANT VENDORS

LEE COUNTY COMMUNITY DEVELOPMENT

BUILDING SERVICES

1500 MONROE STREET

FORT MYERS, FL 33901

SHARON REYNOLDS

(239) 533-8597

(239) 485-8529

TELEPHONE

NAME

ADDRESS

CONTACT

PHONE

SOLAR GLAZING FILM

NAME

ADDRESS

CONTACT

PHONE

FLOORING- (WOOD)

NAME

ADDRESS

CONTACT

PHONE

COMM-WORKS

3550 ANNAPOLIS LANE NORTH

#30

MINNEAPOLIS, MN 55447

LISA OYAAS

(763) 852-5919

CP FILMS

4210 THE GREAT ROAD

FIELDALE, VA 24089

SCOTT CURRY

(888) 257-5470

CTS FLOORING

319 WEST RIDGE PIKE

LIMERICK, PA 19468

JOE PURCELL

(610) 831-5125

P-110

P-501

E-110

E-120

E-501

E-601

E-701

EMS-110

IF-110

IF-701

IF-702

IF-703

IF-704

SHEET INDEX

TILE

NAME

ADDRESS

CONTACT

PHONE

FIXTURES

NAME

ADDRESS

CONTACT

PHONE

NAME

ADDRESS

CONTACT

PHONE

CELL

NAME

ADDRESS

CONTACT

PHONE

PLUMBING

PLUMBING PLAN

PLUMBING PLANS DETAILS AND SPECIFICATIONS

ELECTRICAL

POWER PLAN

LIGHTING PLAN

ELECTRICAL DETAILS

ELECTRICAL SCHEDULES AND LEGENDS

ELECTRICAL SPECIFICATIONS

ENERGY MANAGEMENT SYSTEM INFORMATION

INTERIOR FIXTURES

FIXTURE PLAN

FIXTURE SCHEDULE

FIXTURING INSTRUCTIONS

FIXTURING INSTRUCTIONS

FIXTURING INSTRUCTIONS

FOR REFERENCE ONLY

SITE PLAN - AERIAL

SITE PLAN - TANGER OUTLET CENTERS

DAL-TILE

9220 GAITHER ROAD

ROCKVILLE, MD 20877

DANIEL PANCHURA

(888) 695-8453

IDX LOUISVILLE

110 TECHNOLOGY WAY

JEFFERSONVILLE, IN 47130

BRIAN COTTNER

(812) 280-0000

SPARKS CUSTOM RETAIL

95 METRO VISTA DRIVE

HAWTHORNE, NJ 07506

JOE DEMERI

(215) 671-6107

(201) 679-8417

TAILORING EQUIPMENT

MCALLISTER

8180 INDUSTRIAL PLACE

ALPHARETTA, GA 30004

TODD MCALLISTER

(770) 521-0242

FLOORING- (CARPET)

NAME

ADDRESS

CONTACT

PHONE

SECURITY

NAME

ADDRESS

CONTACT

PHONE

CROWN MOULDING

NAME

ADDRESS

PHONE

HARDWARE

NAME

ADDRESS

CONTACT

PHONE

MOHAWK INDUSTRIES

706 GREEN VALLEY ROAD,

SUITE 300

GREENSBORO, NC 27408

AMANDA BULLINS

(800) 523-5647 X 36711

NUTECH

150 CANDACE DRIVE

MAITLAND, FL 32751

BOB ROSS

(800) 569-1600

OLD WORLD MOULDING, INC.

821 LINCOLN AVENUE

BOHEMIA, NY 11716

(631) 563-8660

TWIN CITY HARDWARE

5650 INTERNATIONAL

PARKWAY

NEW HOPE, MN 55428

ROLFE MC AFEE

(763) 535-4660 X209

A

A

A

DOOR LOCKS

NAME

ADDRESS

CONTACT

PHONE

AUDIO

NAME

ADDRESS

CONTACT

PHONE

SECURITY SOLUTIONS

1640 W. HWY 152

MUSTANG, OK 73064

JONI TURNER

(888) 541-1300 x1006

TRUSONIC

7825 FAY AVE., SUITE LL-A

LA JOLLA, CA 92037

NICK COCCHIOLA

(858) 362-2323

C

B

A

TANGER OUTLET CENTER

SANIBEL (FACTORY)

REVISIONS:

PROJECT:

FILE:

DATE:

DRAWN BY:

SCALE:

20350 SUMMERLIN ROAD,

GROSS AREA

SALES AREA

TAILOR./PRESS AREA

FITTING AREA

TOILET ROOM

SHEET TITLE:

TITLE SHEET

SUITE 8115

FORT MYERS, FL 33908

OCTOBER 18, 2011

ISSUED FOR PLAN REVIEW, LL, CLIENT REVIEW

OCTOBER 18, 2011

ISSUED FOR BID

OCTOBER 27, 2011

A

ADDENDUM A / LANDLORD COMMENTS

G-001.DWG

10/14/2011

G-001

11164

IK

AS NOTED

3,329 sf

2,426 sf

403 sf

346 sf

154 sf

1 2 3 4 5 6

UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1


1 2 3 4 5 6

E

1.

2.

3.

OPEN DATE AND FINAL INSPECTION DATES ARE FINAL.

PROVIDE WEEKLY REPORTS TO THE JAB PROJECT MANAGER VIA E-MAIL ON

FRIDAY MORNING.

PROVIDE WEEKLY PHOTOS EACH FRIDAY VIA E-MAIL.

E

Calvin J.

Coatsworth, AIA

4.

5.

WITHIN 5 DAYS PROVIDE NAMES AND PHONE NUMBERS OF UTILITY COMPANIES

AND METER NUMBERS FOR GAS AND ELECTRIC TO STORE PROJECT COORDINATOR.

FOR CONSTRUCTION QUESTIONS, CONTACT JAB PROJECT MANAGER.

Irvine,

Phone:

Fax:

2495 Campus Drive

Second Floor

California 92612

949. 833. 1930

949. 833. 1140

6.

CHANGE ORDER PROCEDURES:

ANY CHANGES TO THE PLAN MUST BE APPROVED FIRST BY JAB PROJECT MANAGER

PRIOR TO DOING WORK. PROVIDE A COST TO DO EXTRA WORK, IF ANY.

7.

8.

UPON DEMOLITION COMPLETION OR WITHIN 3 DAYS OF CONSTRUCTION START,

PROVIDE TO BOTH JAB PROJECT MANAGER AND THE ARCHITECT A FINAL EXISTING

DIMENSION PLAN.

PROVIDE TO JAB WITHIN 5 DAYS OF CONSTRUCTION START DATE AN ON-SITE

PHONE NUMBER.

EXISTING

LANDLORD

TENANT

G.C.

TENANT

VENDOR

TENANT

EXISTING

LANDLORD

TENANT

G.C.

TENANT

VENDOR

TENANT

FILE LOCATION: p:\2011\11164\Sheets\G-002.dwg PLOT DATE: 10/27/2011 2:51 PM

D

C

B

A

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

COMMUNICATION:

* THE GENERAL CONTRACTOR (G.C.) IS RESPONSIBLE TO MANAGE JAB

SCHEDULES AND SECURE ALL JAB FURNISHED ITEMS.

* DO NOT CONTACT JAB VENDORS TO CHANGE SCHEDULES OR ADD ITEMS

* ANY REQUESTS MADE BY ANYONE EXCEPT THE PROJECT COORDINATOR,

PROJECT MANAGER OR DIRECTOR OF STORE DEVELOPMENT SHOULD NOT

BE GRANTED UNLESS APPROVED BY ONE OF THE ABOVE FIRST!

JAB FURNISHED ITEMS:

* THE G.C. IS EXPECTED TO ACCEPT ALL DELIVERIES WHEN THEY ARRIVE.

ANY REFUSED SHIPMENTS WILL BE AT THE GC'S COST TO RETURN.

* GC IS RESPONSIBLE TO UNLOAD, ACCEPT DELIVERY AND

SECURE ALL JAB ITEMS DURING CONSTRUCTION

* UPON DELIVERY OF ANY JAB ITEMS DELIVERED TO SITE DURING

CONSTRUCTION, THE G.C. IS EXPECTED TO CHECK EACH ITEM AS SOON AS IT IS

RECEIVED AND NOTIFY JAB WITHIN 24 HOURS OF ANY

DISCREPANCY. ANY ITEMS FOUND TO BE DAMAGED OR MISSING

LATER WILL BE PAID BY THE G.C.

THE G.C. IS RESPONSIBLE TO KNOW ALL LOCAL REQUIREMENTS FOR INSPECTION

TIMEFRAMES ON FIRE ALARM OR SPRINKLER SYSTEMS REQUIRED SUBMIT TO CITY

WITHIN 3 DAYS OF CONSTRUCTION START FOR APPROVALS.

UPON ENTERING AGREEMENT, THE G.C. HAS AGREED TO PROVIDE THE NECESSARY

STAFF AS REQUIRED TO COMPLETE THE STORE ON TIME.

JOB SUPERINTENDENT MUST HAVE WORKED WITH YOUR COMPANY FOR AT LEAST

ONE YEAR AND MUST HAVE A MINIMUM OF 3 YEARS EXPERIENCE IN JOB

SUPERVISION. JOB SUPERINTENDENT IS NOT A WORKING PERINTENDENT, BUT ONLY

A SUPERINTENDENT TO BE ON THE JOB, EVERY DAY! SUPERVISOR ON THE JOB.

WITHIN 5 DAYS OF WORK COMMENCING, THE G.C. IS REQUIRED TO INSPECT THE

EXISTING ROOF AND CEILING (IF APPLICABLE) AND ISSUE TO JAB A REPORT

INCLUDING PICTURES OF THE EXISTING CONDITIONS.

G.C. TO PROVIDE ONE 30 YARD DUMPSTER AT FINAL INSPECTION

DAY AND REMOVE PRIOR TO OPENING.

PAYMENTS:

* SUBMIT 3 DRAWS

* EACH DRAW SUBMIT WITH LESS 10% RETAINAGE

IN ORDER TO PROCESS APPLICATIONS FOR PAYMENT IN A TIMELY FASHION, SEND

PAYMENT REQUEST PACKAGES DIRECTLY TO:

JOS. A. BANK CLOTHIERS, INC.

500 HANOVER PIKE

HAMPSTEAD, MARYLAND 21074-2095

ATTENTION: BRENDA CHRONISTER

SUBMITTING EACH PAYMENT REQUEST IN A SECURED FOLDER IN THE FOLLOWING

ORDER WILL ENSURE REQUESTED DOCUMENTATION IS RECEIVED AND WILL NOT BE

SEPARATED. UPON RECEIPT OF A FULLY COMPLETE AND CORRECT DRAW / INVOICE

PACKAGE, JOS. A. BANK WILL EXPEDITE PAYMENT WITH A TWO-WEEK TURNAROUND

TIME. PAYMENT WILL NOT BE MADE IF ITEMS ARE INCORRECT OR MISSING.

A) DRAW 1-30% SUBMIT AT END OF WEEK TWO (2) OF CONSTRUCTION

* LIST OF SUBCONTRACTORS INCLUDING ADDRESSES, TELEPHONE NUMBERS,

AND CONTRACT AMOUNTS

* NOTARIZED PARTIAL LIEN WAIVER (EXHIBIT H) FOR GENERAL CONTRACTOR

INCLUDING DOLLAR AMOUNT (MUST BE ORIGINAL)

* TWO ORIGINAL CONTRACTS FOR SIGNATURE

* INSURANCE CERTIFICATE NAMING JOS. A. BANK CLOTHIERS, INC. AS ADDITIONAL

INSURED

* AIA APPLICATION AND CERTIFICATE FOR PAYMENT (AIA G702 AND G703)

* SEPARATE INVOICE WITH INVOICE NUMBER FOR DRAW NO. 1 (DO NOT

DUPLICATE INVOICE NUMBERS)

* COPY OF ALL APPROVED CHANGE ORDERS

B) DRAW 2-30% SUBMIT AT COMPLETION OF CONSTRUCTION

* LIST OF SUBCONTRACTORS INCLUDING ADDRESSES, TELEPHONE NUMBERS,

AND CONTRACT AMOUNTS

* NOTARIZED PARTIAL LIEN WAIVER (EXHIBIT H) FOR GENERAL CONTRACTOR

INCLUDING DOLLAR AMOUNT (MUST BE ORIGINAL)

* NOTARIZED PARTIAL LIEN WAIVER (EXHIBIT G) FOR EACH SUBCONTRACTOR AND

MATERIAL MAN INCLUDING DOLLAR AMOUNT (MUST BE ORIGINAL)

* PARTIAL LIEN WAIVERS SUBMITTED FOR SUBCONTRACTORS MUST TOTAL AT

LEAST 90% OF DRAW 1 PAYMENT TO GENERAL CONTRACTOR

* AIA APPLICATION AND CERTIFICATE FOR PAYMENT (AIA G702 AND G703)

* SEPARATE INVOICE WITH INVOICE NUMBER FOR DRAW NO. 2 (DO NOT

DUPLICATE INVOICE NUMBERS)

* COPY OF ALL APPROVED CHANGE ORDERS

C) DRAW 3 - 40% {FINAL} SUBMIT AT COMPLETION OF PUNCH LIST

* LIST OF SUBCONTRACTORS INCLUDING ADDRESSES, TELEPHONE NUMBERS, AND

CONTRACT AMOUNTS

* NOTARIZED FINAL LIEN WAIVER (EXHIBIT I) FROM GENERAL CONTRACTOR

INCLUDING DOLLAR AMOUNT (MUST BE ORIGINAL)

* NOTARIZED FINAL LIEN WAIVER (EXHIBIT D) FOR EACH SUBCONTRACTOR AND

MATERIAL MAN INCLUDING DOLLAR AMOUNT (MUST BE ORIGINAL)

SUBCONTRACTORS MUST BE PAID 100% OF THEIR CONTRACT AT THIS POINT.

* NOTARIZED AFFIDAVIT TO OWNER (EXHIBIT J) FROM GENERAL CONTRACTOR

(MUST BE ORIGINAL)

* AIA APPLICATION AND CERTIFICATE FOR PAYMENT (AIA G702 AND G703)

* SEPARATE INVOICE WITH INVOICE NUMBER FOR DRAW NO. 3 (DO NOT DUPLICATE

INVOICE NUMBERS)

* HVAC - NEBB OR AABC CERTIFICATE BALANCE REPORT

* HVAC WARRANTY INFORMATION FOR NEW UNITS

* ORIGINAL "AS-BUILT" PLANS - INCLUDE ALL DIMENSIONS AND UTILITY LOCATIONS

* ONE SET OF "AS-BUILT" SEPIAS

* ORIGINAL SET OF STAMPED BUILDING DEPARTMENT PLANS

* LEAVE A COPY OF STAMPED BUILDING DEPARTMENT PLANS WITH THE STORE

MANAGER - HAVE THE STORE MANAGER SIGN A DOCUMENT INDICATING RECEIPT

OF DRAWINGS AND SUBMIT WITH FINAL DRAW

* COPY OF BUILDING PERMIT

* COPY OF CERTIFICATE OF OCCUPANCY

* COPY OF ALL APPROVED CHANGE ORDERS

* LETTER FROM GENERAL CONTRACTOR THAT THE WORK PERFORMED HAS A ONE

(1) YEAR WARRANTY

* CERTIFICATE OF COMPLETION BY GENERAL CONTRACTOR (AIA G704)

* LETTER FROM GENERAL CONTRACTOR THAT GUARANTES THE FLOORING WAS

INSTALLED BY LICENSED FLOORING CONTRACTOR PER THE MANUFACTURER'S

SPECIFICATION

* LETTER FROM GENERAL CONTRACTOR TO INCLUDE THE FOLLOWING: ALL UTILITIES

METERS HAVE BEEN SET, ALL UTILITY METERS ARE IN WORKING ORDER, THE HVAC

SYSTEM HAS BEEN STARTED UP IN BOTH THE AIR CONDITIONING AND HEAT MODE

AND IN PROPER WORKING ORDER

* COMPLETED PUNCH LIST SIGNED BY STORE MANAGER

* SUCH OTHER DOCUMENTATION AS MAY BE REQUIRED BY OWNER IN ORDER TO

PERMIT OWNER TO RECEIVE ANY CONSTRUCTION ALLOWANCE WHICH MAY BE DUE

OR PAYABLE BY OWNER'S LANDLORD

G.C. TO CLEAN STORE PRIOR TO FINAL INSPECTION DATE OR TURNOVER

AND FINAL CLEANING ON THE AFTERNOON BEFORE TENANT'S OPENING.

IF THE STORE IS NOT COMPLETE ON AGREED DATE, GENERAL CONTRACTOR TO BE

RESPONSIBLE FOR ADDITIONAL COSTS FOR JAB TO REINSPECT STORE.

IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO FIND OUT IF THE PROJECT IS

UNION OR NON-UNION. BID SUBMITTED WILL BE FINAL AND WILL NOT BE ADJUSTED.

NOTE:

FINAL DRAW WITH COMPLETE DOCUMENTS IS DUE ON FINAL INSPECTION DATE.

FOR EVERY 2 WEEKS THE FINAL DRAW IS NOT SUBMITTED, $500.00 WILL BE DEDUCTED.

PRE-CONSTRUCTION

REQUIREMENTS

A

DESCRIPTION

FLOOR CONSTRUCTION

CONCRETE SLAB

SLAB INFILL

CORE DRILL

FLOOR FINISH / BASE

CARPET

VINYL COMPOSITION TILE (VCT)

SHEET VINYL / BASE

WOOD PLANK

WALK-OFF MAT

CERAMIC TILE / BASE

RUBBER BASE

WOOD BASE

TRANSITIONS

SEALED CONCRETE

EXTERIOR WALLS

STOREFRONT FRAMING & FINISH

SIGN BAND

SERVICE DOOR

FURRING & FINISH

INSULATION

INTERIOR WALLS

DEMISING WALL STUDS

DEMISING WALL FINISH

DEMISING WALL INSULATION

PARTITON FRAMING

PARTITION FINISH

DOORS, FRAMES & HARDWARE

VENEER PANELS

FIBER REINFORCED PANELS (FRP)

CORNER GUARDS

REEVE WALL

MEDIUM-DENSITY FIBERBOARD (MDF)

STANDARDS

BRACKETS

WOOD / CARPENTRY

BLOCKING

ROUGH CARPENTRY LUMBER

PLYWOOD

CROWN MOULDING

BASE SHOE (QUARTER-ROUND)

WOOD TRIM

FITTING ROOM BENCH SUPPORT

TELEPHONE BACK BOARD

WOOD SHELF

PAINTING

EXTERIOR

STORE INTERIOR

CEILING / ROOF

ACOUSTICAL CEILING TILE

GYPSUM BOARD CEILING / SOFFITS

ROOF / DECK INSULATION

ROOF WORK

STOREFRONT

STOREFRONT SYSTEM & GLAZING

ENTRY DOORS & HARDWARE

SOLAR GLAZING FILM

SPANDREL FILM

TEMPORARY BARRICADE

MECHANICAL (HVAC)

RHP-1

LOCK CORE - DURING CONSTRUCTION

LOCK CORE - FINAL

ROOF TOP UNIT 2

EXHAUST FAN 1

DUCTWORK & DAMPERS

GRILLES, REGISTERS & DIFFUSERS

THERMOSTATS, SENSORS & WIRING

ROOF TOP UNIT CONNECTIONS

PLUMBING

WATER & SEWER ROUGH-IN

FIXTURES

WATER HEATER

DRINKING FOUNTAINS

PRESS CONNECTIONS

ROOF TOP UNIT CONNECTIONS

RESPONSIBILITY SCHEDULE

FURNISH

INSTALL

FURNISH

INSTALL

PATCH / REPAIR

FURNISH

INSTALL

FURNISH

INSTALL

REMARKS

REFER TO SHEET A-110 FOR SPEC

REFER TO SHEET E-501

N/A

N/A

N/A

N/A

REFER TO EXTERIOR ELEVATIONS FOR SCOPE

REPLACE HARDWARE

LOGO WALL

REFER TO INSTALLATION GUIDELINES ON A-602

N/A

N/A

CUSTOM-CUT FOR LOGO WALL

REFER TO KEYNOTE 17, SHEET IF-110

REFER TO KEYNOTE 16, SHEET A-401

REFER TO EXTERIOR ELEVATIONS FOR SCOPE

LANDLORD REQUIRED SUB-CONTRACTOR

N/A

(When necessary)

REFER TO "CARRIER NATIONAL ACCOUNT INFORMATION"

ON THIS SHEET FOR ADDITIONAL CLARIFICATION.

GAS AND CONDENSATE DRAINAGE SYSTEM

STEAM / WATER

DESCRIPTION

ELECTRICAL

MAIN SERVICE CONNECTION

SUB PANELS

TRANSFORMER

WIRING

OUTLETS

LIGHT FIXTURES

EMERGENCY LIGHT FIXTURES

EXIT SIGNS

SIGN OUTLET WIRING

SPEAKERS / AUDIO

P.O.S. CABLE & CONNECTIONS

TELEPHONE & DATA CONNECTIONS

ROOF TOP UNIT CONNECTIONS

TAILOR SHOP

TAILOR EQUIPMENT

PRESS EQUIPMENT

FIRE PROTECTION

SPRINKLER MAIN

SPRINKLER SYSTEM

FIRE EXTINGUISHERS

FIRE ALARM SYSTEM

SIGNAGE

PRIMARY SIGN

AWNINGS

INTERIOR PLAQUES

EXTERIOR PLAQUES

VINYL GRAPHICS

BLADE SIGN

GRAPHIC PANELS

CABLES & CONNECTIONS

UNISTRUT & THREADED ROD

GROMMET

ACCESSIBLE SIGNAGE

FURNISHINGS

FURNITURE / FIXTURES

CASHWRAP

BENCH

CUSHION

MULTIPLE CLOTHING HOOK

CLOTHES HOOK at 3-WAY MIRROR

REFRIGERATOR

MICROWAVE

STORAGE CABINET

1ST FIXTURE TRUCK

2ND FIXTURE TRUCK

TOILET ROOM ACCESSORIES

GRAB BARS

CLOTHES HOOK

RESTROOM MIRRORS

EXCALIBUR SHELVING

WALL SHELVING

STANDARDS

NAILERS

FRAMED MIRRORS

COLUMN & 3-WAY MIRRORS

MISCELLANEOUS ITEMS

PERMIT

DEMOLITION

DUMPSTER

SECURITY SYSTEM

CLOSE-OUT

CLEANING at TURNOVER

CLEANING at OPENING

AS-BUILTS

CCa PROJECT MANAGER

JAB PROJECT MANAGER

TENANT COORDINATOR

REVIEWED

FURNISH

INSTALL

DATE

FURNISH

10/14/11

INSTALL

CARRIER NATIONAL ACCOUNT INFORMATION

PATCH / REPAIR

APPROVED

FURNISH

INSTALL

DATE

FURNISH

INSTALL

REMARKS

INCLUDING PRESS CONNECTIONS

GC TO PROVIDE POWER TO EQUIPMENT

GC TO PROVIDE CONDUIT AND PULL WIRE

GC TO PROVIDE CONDUIT AND PULL WIRE

GC TO MODIFY AS REQUIRED

COORDINATE WITH LANDLORD AS REQUIRED

AS REQUIRED BY LOCAL JURISDICTION

COORDINATE WITH LANDLORD & LOCAL JURISDICTION

GC TO PROVIDE BLOCKING

LL TO SUPPLY AND INSTALL AT TENANT'S EXPENSE

REFER TO SHEET A-601

TO BE REIMBURSED BY TENANT-DO NOT INCLUDE IN BID

COORDINATE LOCATION WITH LANDLORD

DAY BEFORE STORE OPENING

JOS. A. BANK HAS A DIRECT PURCHASE NATIONAL ACCOUNT AGREEMENT WITH CARRIER CORPORATION FOR CERTAIN HVAC

PRODUCTS. ALL HVAC BIDDERS NEED TO CONTACT THE CARRIER PROJECT MANAGER FOR A COPY OF THE BILL OF MATERIALS.

THE HVAC BIDDER IS RESPONSIBLE FOR THE PURCHASE OF ALL ITEMS NOT INCLUDED ON THE BILL OF MATERIALS THAT ARE

REQUIRED AS PER THESE DRAWINGS AND SPECIFICATIONS. THE HVAC BIDDER IS RESPONSIBLE FOR DELIVERY SCHEDULE, CRANE

SERVICE AND ALL INSTALLATION LABOR, FIRST YEAR WARRANTY LABOR, EQUIPMENT AND SUPPLIES. REFER TO "TENANT VENDORS"

ON SHEET G-001 FOR CARRIER PROJECT MANAGER CONTACT INFO.

REVIEW / APPROVAL

A

A

A

REFER TO RISER DIAGRAM ON SHEET E-501

FOR ADDITIONAL CLARIFICATION.

ALL EXTERIOR SIGNAGE MUST BE WIRED TO LANDLORD

CONTROLLED TIME CLOCK

N/A

N/A

N/A

N/A

N/A

N/A

N/A

G.C. RESPONSIBLE FOR ELECTRICAL CONNECTIONS

G.C. TO PROVIDE LABOR AND UNLOAD

TENANT TO SUPPLY SOAP, PAPER TOWEL,

TOILET DISPENSER AND AIR FRESHNER

REFER TO SHEET IF-110

REFER TO SHEET A-110

CONTACT

ALLISON WALKER

JEFF HANUSIN

KATE DOUGHERTY

D

C

B

A

TANGER OUTLET CENTER

SANIBEL (FACTORY)

REVISIONS:

PROJECT:

FILE:

DATE:

DRAWN BY:

SCALE:

20350 SUMMERLIN ROAD,

GROSS AREA

SALES AREA

TAILOR./PRESS AREA

FITTING AREA

TOILET ROOM

SHEET TITLE:

SUITE 8115

FORT MYERS, FL 33908

OCTOBER 18, 2011

ISSUED FOR PLAN REVIEW, LL, CLIENT REVIEW

OCTOBER 18, 2011

ISSUED FOR BID

OCTOBER 27, 2011

A

ADDENDUM A / LANDLORD COMMENTS

G-002.DWG

10/14/2011

G-002

11164

AJ

AS NOTED

3,329 sf

2,426 sf

403 sf

346 sf

154 sf

RESPONSIBILITY SCHEDULE &

PRE-CONSTRUCTION NOTES

1 2 3 4 5 6

UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1


1 2 3 4 5 6

SALES

SIDE

DN

LINE OF EXISTING

CANOPY ABOVE

DN

FITTING

AREA

005

A-2

A-202

DN

EXISTING SERVICE RAMP

6"

MIN.

D6A

A-501

E6A

A-501

typical

CEILING AS SCHEDULED

ELECTRICAL EQUIPMENT,

REFER TO ELECTRICAL

1 DRAWINGS

1

3'-3"

2

6"

DN

E

8'-0" A.F.F.

4

PARTITION

FITTING ROOMS

5/8" TYPE "X" GYP. BD. BOTH

SIDES AND AT TOP

3 5/8" X 20 GA. METAL

STUDS

WALL BASE PER SCHEDULE

3

PARTITION

CROWN MOULDING

(WHERE OCCURS)

5/8" TYPE "X" GYP. BD. BOTH

SIDES. MOISTURE

RESISTANT @ TOILET

SIM. CONDITION

5/8" GYP. BD. ON

2 1/2" X 25 GA.

METAL STUDS

A6

A-501

typical

WALL BASE PER SCHEDULE

TAILOR

AREA

006

D2

A-202

26'-1"

9'-4"

2'-11"

1'-7"

9'-1 1/2"

2A

CLEAR

CLEAR

SIM.

1E

1E

N.I.C

1E

WOMEN'S

TOILET

004

12'-0"

F

E

Calvin J.

Coatsworth, AIA

Irvine,

Phone:

Fax:

2495 Campus Drive

Second Floor

California 92612

949. 833. 1930

949. 833. 1140

FILE LOCATION: p:\2011\11164\Sheets\A-110.dwg PLOT DATE: 10/27/2011 2:54 PM

D

C

B

A

A

ADJ.

TENANT

CAULK

CAULK

SCALE: 3/4" = 1'-0"

1.

2.

3.

4.

5.

6.

6"

MIN.

1E

1B

6"

MIN.

PARTITION

6"

MIN.

PARTITION

6"

MIN.

2"

1/2"

EXTERIOR WALL

8'-0"

A.F.F.

PARTITION

EXISTING STRUCTURE

D6A

A-501

D6

A-501

TENANT SIDE

E6A

A-501

CEILING AS SCHEDULED

5/8" TYPE "X" GYP. BD.

BOTH SIDES. MOISTURE

RESISTANT @ TOILET

3 5/8" X 20 GA.

METAL STUDS

NOTE:

1. PROVIDE DOUBLE STUDS AT

TOILET ROOM PLUMBING WALL

E6

A-501

TENANT SIDE

EXISTING STRUCTURE

CEILING AS SCHEDULED

ALL EXISTING STRUCTURAL AND BUILDING FIRE PROTECTION SHALL BE

MAINTAINED. G.C. TO REPORT EXISTING DAMAGE TO TENANT AND LANDLORD

PRIOR TO STARTING WORK.

ALL EXISTING LANDLORD UTILITIES SHALL BE PROTECTED. PROJECT SHALL BE

SURVEYED PRIOR TO DEMOLITION AND ANY EXISTING DAMAGE SHALL BE

REPORTED TO THE TENANT AND LANDLORD PRIOR TO STARTING WORK. ANY

REPAIR AND / OR REPLACEMENT OF ACTIVE UTILITIES DAMAGED DURING

DEMOLITION, OR CONSTRUCTION, WILL BE AT G.C.'S EXPENSE.

FIELD LOCATE ALL EXISTING UTILITIES WITHIN 8 INCHES OF PROPOSED CEILING

AND COORDINATE ALL REQUIRED MODIFICATIONS OF EXISTING AND / OR

PROPOSED UTILITIES AS NECESSARY FOR TENANT BUILD-OUT.

CORE AND REMOVE RAISED CONCRETE SLAB AND WOOD SUBFLOOR AS

REQUIRED FOR PROPOSED PLUMBING AND ELECTRICAL DESIGN - REFER TO

PLUMBING AND ELECTRICAL PLANS FOR ADDITIONAL INFORMATION. G.C. TO

COORDINATE WITH LANDLORD FOR SLAB CORING AND ACCESS TO SPACE

BELOW. G.C. TO X-RAY THE SLAB PRIOR TO ANY CORE DRILLING TO ASSURE

THAT ALL UTILITY LINES AND POST TENSION CABLES ARE PROTECTED

CLEAN AND PREPARE EXISTING FLOOR SLAB AS REQUIRED FOR PROPOSED

FINISHES. NOTIFY TENANT DURING BID IF SLAB SURFACE WILL NOT BE ABLE

TO ACCEPT PROPOSED FINISH.

COORDINATE INSTALLATION OF ALL PREFABRICATED ITEMS WITH TENANT PRIOR

TO CONSTRUCTION.

A1 GENERAL NOTES

EXISTING (1) LAYER 5/8" TYPE

"X" GYP. BD., PATCH AND

REPAIR FINISH AS NECESSARY

(WATER RESISTANT @TOILET)

EXISTING EXTERIOR WALL

WALL BASE PER SCHEDULE

B1 PARTITION TYPES

typical

WALL BASE PER SCHEDULE

EXISTING STRUCTURE

FIRE CAULK

CEILING AS SCHEDULED

EXISTING INSULATION

5/8" TYPE "X" GYP. BD. OVER

3 5/8" X 20 GA. METAL STUDS

(WHERE OCCURS) WATER

RESISTANT @ TOILET.

FINISH BY ADJ. TENANT

WALL BASE PER SCHEDULE

DEMISING WALL

1-HR. RATED ASSEMBLY PER U.L. #U465

TOP CAP OVER REEVES

(WHERE OCCURS)

REEVE WALL SYSTEM

(WHERE OCCURS)

D4

REFER TO

A-501

FITTING

AREA

2A 2

EXISTING DEMISING WALL,

PATCH & REPAIR FINISH AS

NECESSARY TO MAINTAIN

1HR RATING

6"

MIN.

ADJ.

TENANT

CAULK

1D

6"

MIN.

2"

1/2"

2"

1/2"

8'-0"

A.F.F.

8'-0"

A.F.F.

PARTITION

7. ALL WOOD BLOCKING / PLYWOOD TO BE FIRE-RETARDANT-TREATED WOOD. 15. AUDIO EQUIPMENT TO BE INSTALLED ON WOOD SHELF AT TELEPHONE BACK

BOARD PER INTERIOR ELEVATIONS. PREFERRED SPEAKER LOCATIONS

8.

IDENTIFIED ON SHEET E-120.

9.

10.

11.

12.

13.

14.

D6

A-501

E6

A-501

TENANT SIDE

EXISTING STRUCTURE

FIRE CAULK

CEILING AS SCHEDULED

TOP CAP OVER REEVES

(WHERE OCCURS)

EXISTING INSULATION

ONE (1) LAYER 5/8" TYPE "X"

GYP. BD. OVER 6"X16" GA.

METAL STUDS 16" O.C. (AS

NECESSARY)

REEVE WALL SYSTEM

(WHERE OCCURS)

D4

REFER TO

FINISH BY ADJ. TENANT

WALL BASE PER SCHEDULE

DEMISING WALL

1-HR. RATED ASSEMBLY PER U.L. #U465

6"

MIN.

EXISTING WALL

REFER TO A-111 FOR LOCATIONS OF CORNER GUARDS AND FLOOR FINISH

TRANSITIONS.

WHEN REQUIRED, REPLACE EXISTING HARDWARE, INCLUDING LOCKSETS AND

CLOSERS AS REQUIRED TO MEET APPLICABLE ACCESSIBILITY REGULATIONS.

ALL DOORS TO BE LOCATED 4" MIN. FROM WALL, UNLESS NOTED OTHERWISE.

LANDLORD WILL SUPPLY AND INSTALL BUILDING STANDARD SUITE

IDENTIFICATION PACKAGE. NO OTHER REAR DOOR SIGNAGE IS PERMITTED.

ENTRANCE, ACCESSIBLE FITTING ROOM AND TOILET ROOMS TO BE IDENTIFIED

BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. REFER TO DETAIL

FOR ADDITIONAL REQUIREMENTS.

A1

ALL REEVE STANDARDS SHALL BE 2'-0" O.C. AND THE ORIGINAL NUMBER OF

STANDARDS SHALL BE CENTERED ON THE LENGTH OF REEVE WALL

DIMENSIONED ON THE PLAN, UNLESS NOTED OTHERWISE.

A-601

FOR ALTERNATE ATTACHMENT AT DECK FOR PARTITION TYPES 2, 2A, AND 3,

REFER TO

D6

E6 B6

AND

A-501

A-501

1A PARTITION EXISTING GLAZING

EXTERIOR WALL

SALES SIDE

PARTITION

W/ REEVE WALL

A

D6A

A-501

E6A

A-501

REEVE WALL SYSTEM

(WHERE OCCURS)

REFER TO

D4

A-501

TENANT SIDE

typical

EXISTING STRUCTURE

TOP CAP OVER REEVES

(WHERE OCCURS)

5/8" TYPE "X" GYP. BD.

BOTH SIDES OVER 3 5/8"

X 20 GA. METAL STUDS

WALL BASE PER SCHEDULE

EXISTING DEMISING WALL,

PATCH & REPAIR FINISH AS

NECESSARY TO MAINTAIN

1HR RATING

EXISTING STRUCTURE

CEILING AS SCHEDULED

PATCH AND REPAIR

EXISTING GYP. BD.

FINISH AS NECESSARY

(ALL EXPOSED SIDES)

WALL BASE PER SCHEDULE

A-501

EXTERIOR

CAULK

A-501

ADJ.

TENANT

CAULK

EXTERIOR

CAULK

1F

1C

1

PARTITION

6"

MIN.

PARTITION

EXTERIOR WALL

6"

MIN.

PARTITION

EXTERIOR WALL

D6

A-501

E6

A-501

TENANT SIDE

EXISTING STRUCTURE

FIRE CAULK

CEILING AS SCHEDULED

EXISTING DEMISING WALL,

PATCH & REPAIR FINISH AS

NECESSARY TO MAINTAIN

1HR RATING

EXISTING INSULATION

ONE (1) LAYER 5/8" TYPE "X"

GYP. BD. OVER 6"X16" GA.

METAL STUDS 16" O.C. (AS

NECESSARY)

FINISH BY ADJ. TENANT

WALL BASE PER SCHEDULE

DEMISING WALL

1-HR. RATED ASSEMBLY PER U.L. #U465

TENANT SIDE

EXISTING STRUCTURE

CEILING AS SCHEDULED

SEPARATION

(WHERE OCCURS)

R13 BATT INSULATION

ONE (1) LAYER 5/8" TYPE "X"

GYP. BD. OVER 3 5/8" X 20

GA. METAL STUDS

EXISTING DEMISING WALL,

PATCH & REPAIR FINISH AS

NECESSARY TO MAINTAIN

1HR RATING

EXISTING EXTERIOR WALL

WALL BASE PER SCHEDULE

TENANT SIDE

CEILING AS SCHEDULED

PATCH AND REPAIR

EXISTING GYP. BD.

FINISH AS NECESSARY

(1) LAYER 5/8" TYPE "X" GYP.

BD., (WHERE NECESSARY)

WATER RESISTANT @ TOILET.

EXISTING EXTERIOR WALL

WALL BASE PER

SCHEDULE

16.

FIRE EXTINGUISHERS SHALL BE MOUNTED NO LOWER THAN 48" A.F.F TO THE

TOP OF HANDLE AND WILL NOT EXCEED 75' TRAVEL DISTANCE. EXTINGUISHERS

TO MEET MINUM OF CODE 2A:20B AND SHALL BE TAGGED BY A LICENSED FIRE

EQUIPMENT COMPANY.

ADJACENT

TENANT

DN

A4 FLOOR PLAN

D2

A-201

3

LINE OF EXISTING

CANOPY ABOVE

1F

1D

1F

1D

1A

2'-6"

TYP.

4'-6"

(3 STANDARDS)

12'-6"

ACCESSORY WALL

(PROVIDE BLOCKING)

26'-0"

(SHIRT WALL)

19'-2 1/2"

(10 STANDARDS)

2

14'-6"

(8 STANDARDS)

2A

SIM.

1A

4

78

6

5

9"

5'-0"

CLEAR

12"X12" ACCESS PANEL IN

CASHWRAP/BACKWRAP TARGET AREA.

COORDINATE WITH ELECTRICAL

DRAWINGS. - typical

CUT THROUGH SLAB AS REQUIRED.

TO INSTALL NEW CONDUITS. (SEE

ELECTRICAL) PATCH AS REQUIRED

FOR NEW FINISH.

37'-10 3/4"

4'-0"

CLEAR

B3

A-402

2A

ENTRY

001

1/2"

16'-4 3/4" 20'-8" 10"

DN

A2

A-201

CLEAR

1

2

3

2A

7'-1 1/2"

7 8

8'-6"

(5 STANDARDS)

5'-3"

1'-4 1/2"

2A

CLEAR

6'-6"

2A

4 4

3

SIM

1

17'-0"

(8 STANDARDS)

28'-10"

(15 STANDARDS)

1C

1

4

1

1C

1B

1B

1

DN

3

79

A1

A-402

B1

A-402

D3

A-402

8'-0"

BACKWRAP

DN

MEN'S

TOILET

003

SALES

AREA

002

A1

A-203

LINE OF EXISTING

CANOPY ABOVE

10" 10'-7" 20'-0" 30'-0" 30'-0"

80'-3 3/4"

E

D

C.3

C

EXISTING

HANDICAP RAMP

D1

A-203

D

C

B

A

TANGER OUTLET CENTER

SANIBEL (FACTORY)

REVISIONS:

PROJECT:

FILE:

DATE:

DRAWN BY:

SCALE:

20350 SUMMERLIN ROAD,

GROSS AREA

SALES AREA

TAILOR./PRESS AREA

FITTING AREA

TOILET ROOM

SHEET TITLE:

FLOOR PLAN

SUITE 8115

FORT MYERS, FL 33908

OCTOBER 18, 2011

ISSUED FOR PLAN REVIEW, LL, CLIENT REVIEW

OCTOBER 18, 2011

ISSUED FOR BID

OCTOBER 27, 2011

A

ADDENDUM A / LANDLORD COMMENTS

A-110.DWG

10/14/2011

A-110

11164

AJ

AS NOTED

3,329 sf

2,426 sf

403 sf

346 sf

154 sf

SCALE: 1/4" = 1'-0"

1 2 3 4 5 6

UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1


1 2 3 4 5 6

LINE OF EXISTING

CANOPY ABOVE

E

E

Calvin J.

Coatsworth, AIA

FIRE EXTINGUISHER , MOUNTED

48" ABOVE FINISH FLOOR

ALARM PAD

LEASE LINE

DN

Irvine,

Phone:

Fax:

2495 Campus Drive

Second Floor

California 92612

949. 833. 1930

949. 833. 1140

EXISTING STOREFRONT SYSTEM AND ENTRY

DOOR, PATCH & REPAIR FINISH AS NECESSARY

COLOR: CLEAR ANODIZED

16'-4 1/2" 20'-8" 10"

37'-11"

D

DN

LINE OF EXISTING

CANOPY ABOVE

DN

DN

EXISTING HANDICAP RAMP

D

D2 ENLARGED PLAN

A2

-

SCALE: 3/8"=1'-0"

C

C

LEASE

LINE

C5

A-204

A5

A-204

B

EXISTING MANSARD ROOF, typical

COLOR: TURQUOISE

EXISTING VINYL SIDING. PATCH & REPAIR, REPAINT

FINISH AS NECESSARY, typical

COLOR: WHITE

EXISTING BACK-UP LIGHT FIXTURE.

PATCH & REPAIR AS NECESSARY, typical

COLOR: CREAM

EXISTING WALKWAY CANOPY, typical

COLOR: TURQUOISE

EXISTING COVERED WALKWAY LIGHT FIXTURES.

PATCH & REPAIR AS NECESSARY, typical

COLOR: YELLOW

B4

A-204


SIGN & DOOR


EQUAL

EQUAL

JOS. A . BANK REVERSE

ILLUMINATED CHANNEL LETTERS,

PLEASE REFER TO

C3-A

EXISTING FIRE ALARM

COLOR: RED

A-204

EXISTING VINYL SIDING. PATCH & REPAIR, REPAINT

FINISH AS NECESSARY, typical

COLOR: WHITE

EXISTING COLUMN AND TRIM. PATCH & REPAIR

AS NECESSARY , typical

COLOR: PURPLE

B

TANGER OUTLET CENTER

SANIBEL (FACTORY)

20350 SUMMERLIN ROAD,

REVISIONS:

SUITE 8115

FORT MYERS, FL 33908

OCTOBER 18, 2011

ISSUED FOR PLAN REVIEW, LL, CLIENT REVIEW

OCTOBER 18, 2011

ISSUED FOR BID

OCTOBER 27, 2011

A

ADDENDUM A / LANDLORD COMMENTS

FILE LOCATION: p:\2011\11164\Sheets\A-201.dwg PLOT DATE: 10/27/2011 2:51 PM

A

1. SOLAR CONTROL GLAZING FILM: TENANT TO PROVIDE SOLAR CONTROL GLAZING

FILM N-1050 SRCDF BY CPFILMS (OR EQUAL) FOR ALL EXISTING EAST, SOUTH,

OR WEST FACING STOREFRONT GLAZING SYSTEMS. FILM MUST BE APPLIED

PRIOR TO INSTALLATION OF VINYL LETTERS AND STORE HOUR GRAPHIC. SOLAR

CONTROL GLAZING FILM TO BE APPLIED TO NEW STOREFRONT GLAZING AT TIME

OF FABRICATION ON THE INTERIOR SIDE OF NEW STOREFRONT GLAZING.

2. SIGNAGE IS NOT A PART OF PLAN REVIEW. SIGNAGE IS TO BE REVIEWED UNDER

SEPARATE PERMIT BY SIGN CONTRACTOR.

3. T = TEMPERED GLASS

4. LOGO DECAL - 3" WHITE FROSTED VINYL LETTERS TO BE CENTERED IN

STOREFRONT WINDOW. FIELD MODIFY AS NECESSARY TO AVOID CONFLICT WITH

GLAZING JOINTS OR MULLIONS SO LETTERS REMAIN WHOLE.

A

LANDLORD NOTES:

*

ALL STOREFRONT WORK MUST MATCH THE EXISTING BUILDING STANDARD,

INCLUDING BUT NOT LIMITED TO: MATERIALS, COLOR FINISH, QUALITY & METHOD OF

INSTALLATION.

*

ANY REPAIR OR REPAINTING OF THE EXTERIOR OF THE PREMISES MUST BE DONE BY

THE LANDLORD'S PREFERRED CONTRACTOR. CONTACT THE MALL OFFICE AT

239-454-1974 FOR THE COMPANY INFO.

A1 ELEVATION NOTES

EXISTING SPANDREL WINDOW FILM

COLOR: BLACK

EXISTING HANDRAILS. PATCH & REPAIR

FINISH AS NECESSARY, typical

COLOR: PURPLE

EXISTING STOREFRONT SYSTEM

PATCH & REPAIR FINISH AS NECESSARY

COLOR: CLEAR ANODIZED

EXISTING HANDICAP RAMP,

PATCH & REPAIR FINISH AS NECESSARY,

typical

A2 EXTERIOR ELEVATION

EQ.

typical

EQ.

typical

12"

typical

OPEN TO STOREFRONT BEYOND

WHITE STORE HOURS GRAPHIC

BLADE SIGN BY LANDLORD

EXISTING STOREFRONT SYSTEM &

ENTRY DOORS TO REMAIN, typical

WINDOW DECAL, typical

A

A

PROJECT:

FILE:

DATE:

DRAWN BY:

SCALE:

GROSS AREA

SALES AREA

TAILOR./PRESS AREA

FITTING AREA

TOILET ROOM

SHEET TITLE:

A-201.DWG

10/14/2011

EXTERIOR ELEVATION &

ENLARGED PLAN

A-201

11164

AJ

AS NOTED

3,329 sf

2,426 sf

403 sf

346 sf

154 sf

SCALE: 3/8"=1'-0"

1 2 3 4 5 6

UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1


1 2 3 4 5 6

N.I.C

E

ELECTRICAL EQUIPMENT,

REFER TO ELECTRICAL DRAWINGS

E

Calvin J.

Coatsworth, AIA

DN

NEW SERVICE DOOR BY TENANT

Irvine,

Phone:

Fax:

2495 Campus Drive

Second Floor

California

92612

949.

833.

1930

949.

833.

1140

6" 3'-3"

EXISTING SERVICE RAMP

LINE OF EXISTING

CANOPY ABOVE

DN DN DN

10"

20'-8"

16'-4 1/2"

D

37'-11"

D

D2 ENLARGED PLAN

A2

-

SCALE: 3/8"=1'-0"

C

C

LEASE

LINE

TANGER OUTLET CENTER

SANIBEL (FACTORY)

20350 SUMMERLIN ROAD,

SUITE 8115

EXISTING MANSARD ROOF, typical

COLOR: TURQUOISE

FORT MYERS, FL 33908

JOS. A . BANK REVERSE ILLUMINATED

CHANNEL LETTERS, REFER TO

C3-B

A-204

B4

A-204


SIGN


SIGN

EQUAL

REVISIONS:

OCTOBER 18, 2011

ISSUED FOR PLAN REVIEW, LL, CLIENT REVIEW

OCTOBER 18, 2011

ISSUED FOR BID

OCTOBER 27, 2011

A

ADDENDUM A / LANDLORD COMMENTS

B

EXISTING VINYL SIDING. PATCH & REPAIR

FINISH AS NECESSARY, typical

COLOR: WHITE EQUAL EQUAL

EQUAL

B

EXISTING COLUMN AND TRIM. PATCH & REPAIR, REPAINT

AS NECESSARY , typical

COLOR: PURPLE

FILE LOCATION: p:\2011\11164\Sheets\A-202.dwg PLOT DATE: 10/27/2011 2:51 PM

A

1. SOLAR CONTROL GLAZING FILM: TENANT TO PROVIDE SOLAR CONTROL GLAZING

FILM N-1050 SRCDF BY CPFILMS (OR EQUAL) FOR ALL EXISTING EAST, SOUTH,

OR WEST FACING STOREFRONT GLAZING SYSTEMS. FILM MUST BE APPLIED

PRIOR TO INSTALLATION OF VINYL LETTERS AND STORE HOUR GRAPHIC. SOLAR

CONTROL GLAZING FILM TO BE APPLIED TO NEW STOREFRONT GLAZING AT TIME

OF FABRICATION ON THE INTERIOR SIDE OF NEW STOREFRONT GLAZING.

2. SIGNAGE IS NOT A PART OF PLAN REVIEW. SIGNAGE IS TO BE REVIEWED UNDER

SEPARATE PERMIT BY SIGN CONTRACTOR.

3. T = TEMPERED GLASS

4. LOGO DECAL - 3" WHITE FROSTED VINYL LETTERS TO BE CENTERED IN

STOREFRONT WINDOW. FIELD MODIFY AS NECESSARY TO AVOID CONFLICT WITH

GLAZING JOINTS OR MULLIONS SO LETTERS REMAIN WHOLE.

A

LANDLORD NOTES:

*

ALL STOREFRONT WORK MUST MATCH THE EXISTING BUILDING STANDARD,

INCLUDING BUT NOT LIMITED TO: MATERIALS, COLOR FINISH, QUALITY & METHOD OF

INSTALLATION.

*

ANY REPAIR OR REPAINTING OF THE EXTERIOR OF THE PREMISES MUST BE DONE BY

THE LANDLORD'S PREFERRED CONTRACTOR. CONTACT THE MALL OFFICE AT

239-454-1974 FOR THE COMPANY INFO.

A1 ELEVATION NOTES

NEW SERVICE DOOR BY TENANT

EXISTING N.I.C. DOOR

COLOR: WHITE

EXISTING HANDRAILS. PATCH & REPAIR

FINISH AS NECESSARY, typical

COLOR: PURPLE

EXISTING SERVICE RAMP, PATCH & REPAIR

FINISH AS NECESSARY, typical

A2 EXTERIOR ELEVATION

A

PROJECT:

FILE:

DATE:

DRAWN BY:

SCALE:

GROSS AREA

SALES AREA

TAILOR./PRESS AREA

FITTING AREA

TOILET ROOM

SHEET TITLE:

A-202.DWG

10/14/2011

EXTERIOR ELEVATION &

ENLARGED PLAN

A-202

11164

AJ

AS NOTED

3,329 sf

2,426 sf

403 sf

346 sf

154 sf

SCALE: 3/8"=1'-0"

1 2 3 4 5 6

UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1


1 2 3 4 5 6

E

E

Calvin J.

Coatsworth, AIA

DN

Irvine,

Phone:

Fax:

2495 Campus Drive

Second Floor

California 92612

949. 833. 1930

949. 833. 1140

DN

D

EXISTING HANDICAP RAMP

LINE OF EXISTING

CANOPY ABOVE

D

10" 10'-7" 20'-0" 30'-0"

A1

-

D1 ENLARGED PLAN

SCALE: 3/8"=1'-0"

1. SOLAR CONTROL GLAZING FILM: TENANT TO PROVIDE SOLAR CONTROL GLAZING

FILM N-1050 SRCDF BY CPFILMS (OR EQUAL) FOR ALL EXISTING EAST, SOUTH,

OR WEST FACING STOREFRONT GLAZING SYSTEMS. FILM MUST BE APPLIED

PRIOR TO INSTALLATION OF VINYL LETTERS AND STORE HOUR GRAPHIC. SOLAR

CONTROL GLAZING FILM TO BE APPLIED TO NEW STOREFRONT GLAZING AT TIME

OF FABRICATION ON THE INTERIOR SIDE OF NEW STOREFRONT GLAZING.

C3 ELEVATION NOTES

2. SIGNAGE IS NOT A PART OF PLAN REVIEW. SIGNAGE IS TO BE REVIEWED

UNDER SEPARATE PERMIT BY SIGN CONTRACTOR.

3. T = TEMPERED GLASS

4. LOGO DECAL - 3" WHITE FROSTED VINYL LETTERS TO BE CENTERED IN

STOREFRONT WINDOW. FIELD MODIFY AS NECESSARY TO AVOID CONFLICT

WITH GLAZING JOINTS OR MULLIONS SO LETTERS REMAIN WHOLE.

A

LANDLORD NOTES:

ALL STOREFRONT WORK MUST MATCH THE EXISTING BUILDING STANDARD,

INCLUDING BUT NOT LIMITED TO: MATERIALS, COLOR FINISH, QUALITY & METHOD OF

INSTALLATION. *ANY

*

REPAIR OR REPAINTING OF THE EXTERIOR OF THE PREMISES MUST BE DONE BY

THE LANDLORD'S PREFERRED CONTRACTOR. CONTACT THE MALL OFFICE AT

239-454-1974 FOR THE COMPANY INFO.

C

C

EXISTING MANSARD ROOF, typical

COLOR: TURQUOISE

B4

A-204

TANGER OUTLET CENTER

SANIBEL (FACTORY)

20350 SUMMERLIN ROAD,

SUITE 8115

FORT MYERS, FL 33908

JOS. A . BANK REVERSE ILLUMINATED

CHANNEL LETTERS, REFER TO

C3-B

A-204

EXISTING VINYL SIDING. PATCH & REPAIR

FINISH AS NECESSARY, typical

COLOR: WHITE

℄ SIGN & WINDOW


SIGN

EQUAL

EQUAL

REVISIONS:

OCTOBER 18, 2011

ISSUED FOR PLAN REVIEW, LL, CLIENT REVIEW

OCTOBER 18, 2011

ISSUED FOR BID

OCTOBER 27, 2011

A

ADDENDUM A / LANDLORD COMMENTS

B

B

FILE LOCATION: p:\2011\11164\Sheets\A-203.dwg PLOT DATE: 10/27/2011 2:51 PM

A

EXISTING COLUMN AND TRIM. PATCH & REPAIR

AS NECESSARY , typical

COLOR: PURPLE

EXISTING HANDRAILS. PATCH & REPAIR

FINISH AS NECESSARY, typical

COLOR: PURPLE

A1 EXTERIOR ELEVATION

A

PROJECT:

FILE:

DATE:

DRAWN BY:

SCALE:

GROSS AREA

SALES AREA

TAILOR./PRESS AREA

FITTING AREA

TOILET ROOM

SHEET TITLE:

A-203.DWG

10/14/2011

EXTERIOR ELEVATION &

ENLARGED PLAN

A-203

11164

AJ

AS NOTED

3,329 sf

2,426 sf

403 sf

346 sf

154 sf

SCALE: 3/8"=1'-0"

1 2 3 4 5 6

UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1


1 2 3 4 5 6

E

E

Calvin J.

Coatsworth, AIA

Irvine,

Phone:

Fax:

2495 Campus Drive

Second Floor

California 92612

949. 833. 1930

949. 833. 1140

D

1. ALL TENANT SIGNAGE INDICATED IN THESE DRAWINGS ARE FOR SCHEMATIC

PURPOSES AND ARE FOR REFERENCE ONLY.

2. IT IS THE RESPONSIBILITY OF THE TENANT'S SIGN VENDOR TO VERIFY ZONING

REQUIREMENTS WITH THE LOCAL JURISDICTION.

PLYWOOD BACKING FOR

TENANT SIGNAGE

D

3. SIGNAGE SHOP DRAWINGS MUST BE SUBMITTED TO JOS A BANK AND THE

LANDLORD FOR REVIEW. WRITTEN APPROVAL MUST BE OBTAINED PRIOR TO

FABRICATION.

JAB SIGN, REFER TO

C3-A

-

4. ALL TENANT SIGNAGE TO BE UNDER SEPARATE PERMIT.

5. FOR ALL FINISH TAGS, REFER TO FINISH SCHEDULE ON SHEET A-602.

SUSPENDED CEILING

6"

EXISTING VINYL SIDING. PATCH & REPAIR

FINISH AS NECESSARY, typical

COLOR: WHITE

D3 SIGNAGE NOTES

A

D4 NOT USED

10'-6" A.F.F.

T.O. CEILING

5/8" TYPE "X" GYP.

BD., PAINTED - typical

DAY/NIGHT JoS. A. BANK REVERSE ILLUMINATED CHANNEL LETTERS

FOR MOUNTING INFORMATION, REFER TO

B4

-

5/8" TYPE "X" GYP. BD., PAINTED - typical

PATCH & REPAIR FINISH AS NECESSARY

18'-0"

A

BLADE SIGN BY LANDLORD

C

2'-6"

A

11'-2"

DAY/NIGHT JoS. A. BANK REVERSE ILLUMINATED CHANNEL LETTERS

FOR MOUNTING INFORMATION, REFER TO

B4

-

A

CP

1

EXISTING STOREFRONT

ENTRY DOOR, PATCH & REPAIR

FINISH AS NECESSARY, typical

EXITING

HANDICAP RAMP

(NOT SEEN)

10'-0"

STOREFRONT

C

1'-6"

C3 SIGN ELEVATION

B

C5 SECTION THROUGH STOREFRONT OPENING

TANGER OUTLET CENTER

SANIBEL (FACTORY)

SCALE: 1/2" = 1'-0"

ACCESS DOOR

REMOTE G.F.I.

TRANSFORMER

5"

ALUMINUM RETURNS

EDGE TRIM

PLEXIGLAS FACE

NEON TUBING

SCALE: 1/2" = 1'-0"

20350 SUMMERLIN ROAD,

REVISIONS:

SUITE 8115

FORT MYERS, FL 33908

OCTOBER 18, 2011

ISSUED FOR PLAN REVIEW, LL, CLIENT REVIEW

OCTOBER 18, 2011

ISSUED FOR BID

OCTOBER 27, 2011

A

ADDENDUM A / LANDLORD COMMENTS

B

METAL ENCLOSURE,

LOCATE IN FIELD

ATTACH TO EXISTING

EXTERIOR WALL SYSTEM

BENDBACKS

ELECTROBITS W/ U.L.

COMPONENTS

SIGNBAND

TUBE SUPPORT

PLYWOOD BACKING FOR

TENANT SIGNAGE

JAB SIGN, REFER TO

C3-A

-

B

FILE LOCATION: p:\2011\11164\Sheets\A-204.dwg PLOT DATE: 10/27/2011 2:51 PM

A

B4 SIGN SECTION

SCALE: N.T.S.

CONCEALED

FASTENINGS

WEEP HOLE W/ COVER

A

SUSPENDED CEILING

10'-6" A.F.F.

T.O. CEILING

5/8" TYPE "X" GYP.

BD., PAINTED - typical

5/8" TYPE "X" GYP. BD., PAINTED - typical

PATCH & REPAIR FINISH AS NECESSARY

CP

1

A5 SECTION THROUGH STOREFRONT GLAZING

6"

EXISTING VINYL SIDING. PATCH & REPAIR

FINISH AS NECESSARY, typical

COLOR: WHITE

EXISTING LIGHT FIXTURES.

PATCH & REPAIR AS

NECESSARY, typical

COLOR: YELLOW

EXISTING STOREFRONT

SYSTEM, PATCH & REPAIR

FINISH AS NECESSARY, typical

EXITING

HANDICAP RAMP

(NOT SEEN)

10'-0"

STOREFRONT

A

PROJECT:

11164

FILE:

A-204.DWG

DATE:

10/14/2011

DRAWN BY:

AJ

SCALE:

AS NOTED

GROSS AREA

3,329 sf

SALES AREA

2,426 sf

TAILOR./PRESS AREA 403 sf

FITTING AREA

346 sf

TOILET ROOM

154 sf

SHEET TITLE:

STOREFRONT DETAILS

A-204

SCALE: 1/2" = 1'-0"

1 2 3 4 5 6

UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1