22.03.2015 Views

Restroom Compartments - Ambienta Phenolic HR1 Installation Guide

Installation instructions for the Ambienta Phenolic HR1 Restroom Compartment

Installation instructions for the Ambienta Phenolic HR1 Restroom Compartment

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong> <strong>Guide</strong>


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Contents<br />

Chapter 1 - Component<br />

Divider Pedestal<br />

.......................................................... 04<br />

Division U - Bracket<br />

.......................................................... 04<br />

End Pilaster L - Bracket<br />

.......................................................... 05<br />

Cubicle Door Coat Hook<br />

.......................................................... 05<br />

Cubicle Head Rail <strong>HR1</strong><br />

.......................................................... 06<br />

Cubicle Door Hinge<br />

.......................................................... 06<br />

Cubicle Door Lock & Keep<br />

.......................................................... 07<br />

Asian Cubicle Division Channel .......................................................... 07<br />

Chapter 2 - Preparation<br />

2.1 Preparation .......................................................... 09<br />

Chapter 3 - <strong>Installation</strong><br />

3.1 Typical Cubicle Module .......................................................... 11<br />

3.2 U - Bracket Fixing Detail .......................................................... 12<br />

3.3 Cubicle Division Adjustable Foot Fixing .......................................................... 13<br />

3.4 Cubicle / Urinal Division Fixing Detail .......................................................... 14<br />

3.5 Centre Pilaster Fixing Detail .......................................................... 15<br />

3.6 L - Bracket Fixing Detail .......................................................... 16<br />

3.7 Wall End Pilaster Fixing Detail .......................................................... 17<br />

3.8 Asian Cubicle Division Channel Fixing Detail .......................................................... 18<br />

3.9 Head Rail Fixing Detail .......................................................... 19<br />

3.10 Door Hinge Fixing Detail .......................................................... 20<br />

3.11 Cubicle Lock Fixing Detail .......................................................... 21<br />

3.12 Cubicle Indicator Keep Fixing Detail .......................................................... 22<br />

3.13 Complete Cubicle Module .......................................................... 23<br />

Support<br />

Contact Us .......................................................... 25<br />

<strong>Ambienta</strong> Architectural Systems © 02


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Chapter 1<br />

Components<br />

<strong>Ambienta</strong> Architectural Systems © 03


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Components<br />

Division Pedestal: TRF WC - 001 / TRF WC - 020<br />

The adjustable Divider Pedestal fixes to the divider<br />

panel with a Connector Bolt which is included.<br />

Fixings to the floor are not supplied, please check floor<br />

substrate and use suitable plug fixings.<br />

Note:<br />

WC - 001 to suit 1/2" (12.5 mm) <strong>Phenolic</strong> Panel<br />

WC - 020 to suit 3/4" (18 mm) <strong>Phenolic</strong> Panel<br />

Divider U - Bracket: WC - 002<br />

The Divider U - Bracket is used to fix the cubicle<br />

divider to the centre pilaster, return end pilaster and, if<br />

using <strong>Ambienta</strong> Facade Wall Panels, to the Module B<br />

Vertical Post / or wall.<br />

Fixings incorporated included 1 no. Connector<br />

Bolt (WC - 008) when fixing through the cubicle<br />

divider, and 2 no. Multi Purpose Screws<br />

WC - 009) when f ixing to the centre pilaster.<br />

When fixing to the <strong>Ambienta</strong> Vertical Post fix<br />

through to the substrate behind. Wall fixings are not<br />

included.<br />

<strong>Ambienta</strong> Architectural Systems © 04


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Components<br />

End Pilaster L - Bracket: WC - 003<br />

The L - Bracket is used to secure the wall end<br />

pilaster to the <strong>Ambienta</strong> Facade wall lining panel,<br />

between walls in the cubicle area.<br />

Fixings incorporated included:<br />

- 1 no. Connector Bolt (WC - 008)<br />

- 1 no. Brass Insert (WC - 012)<br />

- 2 no. Multi Purpose Screws (WC - 009)<br />

Cubicle Door Coat Hook: WC - 004<br />

The Coat Hook is fixed to the rear face of all standard<br />

and ambulant cubicle doors.<br />

It has an integrated buffer that conceals the fixing<br />

point. This screws into a Brass Insert that is pre-fit into<br />

the cubicle doors.<br />

<strong>Ambienta</strong> Architectural Systems © 05


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Components<br />

Cubicle Head Rail: TRF WC - 005<br />

The Cubicle Head Rail (<strong>HR1</strong>) is supplied in 10' (3 m) lengths.<br />

This is fixed to the top edge of all wall end, return end<br />

and centre pilaster’s, using the Multi Purpose Screw<br />

(WC - 009), 2 no. per centre pilaster.<br />

Ensure that the cut end of the required length is<br />

positioned at the wall end of the cubicle module.<br />

Cubicle Door Hinge: WC - 006<br />

The cubicle door hinge is supplied as a pack of 3<br />

hinges suitable for 1 no. cubicle door, standard or<br />

ambulant.<br />

The pack contains 2 no. floating hinge’s and 1 no. rise<br />

and fall hinge.<br />

The hinge packs are handed to suit the door hanging<br />

and 1 no. hinge is pre set with a 15 degree opening<br />

angle (Top Hinge).<br />

The hinges are fixed using the hinge screws<br />

(WC - 011) 4 no. per hinge, 12 no. per hinge pack.<br />

<strong>Ambienta</strong> Architectural Systems © 06


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Components<br />

Cubicle Door Lock & Keep: WC - 007<br />

The Cubicle Door Lock contains a rotary indicator<br />

latch, which is operated by a rotating handle, that in the<br />

closed position locks the cubicle.<br />

The external face of the locking mechanism is<br />

equipped with a vacant / engaged indicator, and<br />

emergency release fixing.<br />

Fixings for the lock are incorporated within the<br />

product. The Keep requires the Keep Fixing Screw .<br />

Asian Cubicle Division Channel: WC - 014<br />

The Asian Cubicle Channel is supplied as a two part<br />

set, to include two channel lengths, 400 and 1700 mm.<br />

The channel is cut, drilled and fixed to the floor on site<br />

with fixings supplied by others. A suitable mastic<br />

sealant is applied prior to the cubicle division<br />

positioned to suit.<br />

Excess sealant is removed, leaving a hygienic, clean<br />

finished edge.<br />

<strong>Ambienta</strong> Architectural Systems © 07


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Chapter 2<br />

Preparation<br />

<strong>Ambienta</strong> Architectural Systems © 08


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Preparation<br />

2.1 In - Line Cubicle <strong>Installation</strong> Preparation<br />

Before installing <strong>Ambienta</strong> - In Line Cubicles please consider the following:<br />

- Ensure that the <strong>Ambienta</strong> Facade Wall Lining System has been installed correctly and that all relevant vertical flash gap<br />

details are / have been achieved.<br />

- Review the restroom drawing package to ensure that the distance between walls / panels is correct.<br />

- Identify that all components match the Bill of Materials (BOM) for the cubicle module type and check component<br />

quantities.<br />

- The scribing of cubicle panels should not be a requirement. If there is a requirement, the end pilasters can be scribed on<br />

site and the exposed panel edges must be chamfered and finished.<br />

- Suitable fixings have been considered to suit the wall / floor substrate and environment.<br />

- All the necessary PPE gear has been issued and all health and safety checks have been made.<br />

<strong>Ambienta</strong> Architectural Systems © 09


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

Chapter 3<br />

<strong>Installation</strong><br />

<strong>Ambienta</strong> Architectural Systems © 10


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.1 Typical Cubicle Module<br />

1<br />

2<br />

4<br />

3<br />

6<br />

5<br />

1. Wall End Pilaster<br />

2. Ambulant Cubicle Door (left hand)<br />

3. Ambulant Centre Pilaster (rebate and pre - machined holes to suit multiple door opening directions)<br />

4. Western Cubicle Division<br />

5. Standard Cubicle Door (right hand)<br />

6. Return End Pilaster<br />

<strong>Ambienta</strong> Architectural Systems © 11


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.2 U - Bracket Fixing Detail<br />

1<br />

2<br />

Locate the pre - machined holes on the <strong>Ambienta</strong> Facade Module B Vertical Post or wall. Ensure that the Flash Gap Strip has been<br />

attached first. Fix the U - Brackets to the Vertical Post. There are 4 no. U - Brackets required per Module B Upright where a cubicle<br />

or urinal division is positioned.<br />

1. Place U - Bracket (WC - 002) onto the Module B Vertical Post, over the flash gap strip.<br />

2. Fix U - Bracket to Vertical Post using fixings supplied by others, fixing through to the substrate<br />

<strong>Ambienta</strong> Architectural Systems © 12


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.3 Cubicle Pedestal<br />

1<br />

2<br />

4<br />

3<br />

Fix the adjustable Pedestal 250 mm set in from the front face of all cubicle modules and 150 mm in from the front edge of the urinal<br />

division.<br />

1. Unscrew and remove the pedestal body<br />

2. Lift off cover rose to expose fixing holes on the pedestal base<br />

3. Place pedestal base in desired position and mark holes<br />

4. Drill pilot holes into the floor, check floor substrate prior to drilling<br />

5. Fix foot base to the floor using suitable plugs and fixings (supplied by others)<br />

6. Cover the pedestal base with cover rose and screw pedestal body back into place<br />

7. Adjust pedestal to required height<br />

<strong>Ambienta</strong> Architectural Systems © 13


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.4 Cubicle / Urinal Division Fixing Detail<br />

1 2 3<br />

4 5<br />

Insert cubicle / urinal divider panel into the pedestal and slide up against the Module B Vertical Post with the U - Brackets fixed in<br />

place. Fix the divider to the pedestal and then to the U - Brackets.<br />

1. Place divider onto Pedestal (WC - 001 shown)<br />

2. Mark hole positions on the divider<br />

3. Drill 9.5 mm dia through hole<br />

4. Use Connecting Bolt supplied with Pedestal to fix the division<br />

5. Fix with allen key (supplied by others)<br />

6. Repeat process when fitting division to the U - Brackets<br />

<strong>Ambienta</strong> Architectural Systems © 14


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.5 Centre Pilaster Fixing Detail<br />

1 2<br />

3<br />

4<br />

All centre pilasters are handed with pre - drilled hinge and U - Bracket holes. Fix the centre pilaster (standard / ambulant) to the<br />

cubicle divider using the U - Brackets, Multi Purpose Screws and Connector Bolts.<br />

1. Fix U - Brackets (WC - 002) to centre pilaster using 2 no. Multi Purpose Screws (WC - 009)<br />

2. Place the centre pilaster into position with the cubicle divider and mark hole for the Connector Bolt (WC - 008)<br />

3. Drill 9.5 mm through hole<br />

4. Use an allen key (supplied by others) to fix the Connecting Bolt<br />

<strong>Ambienta</strong> Architectural Systems © 15


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.6 L - Bracket Fixing Detail<br />

1<br />

2 3<br />

Fix the L - Brackets to the wall end panels/ wall ensuring that all brackets align with the U - Brackets on the cubicle divider.<br />

1. Mark hole positions for 4 no. L - Brackets (WC - 003) onto the wall end panel /wall<br />

2. Drill 2 no. 3.5 mm dia, 10 mm deep holes (countersink 2 mm) for each L - Bracket<br />

3. Fix each L - Bracket to the wall end panel /wall using 2 no. Multi Purpose Screws (WC - 009)<br />

<strong>Ambienta</strong> Architectural Systems © 16


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.7 Wall End Pilaster Fixing Detail<br />

1<br />

2<br />

3 4<br />

The L - Bracket is then used to fix the wall end pilaster to the wall end panel or wall.<br />

1. Position the wall end pilaster against the wall end panel or wall with the previously fixed L - Brackets (WC - 003)<br />

2. Mark hole positions on the wall end pilaster<br />

3. Drill an 8.2 mm dia, 9.5 mm deep hole (counterbore 9.5 mm dia, 1 mm deep) per L - Bracket. Insert the Brass Insert<br />

(10 - V02) into the drilled holes<br />

4. Use an allen key (supplied by others) to fix the Connecting Bolt (WC - 008) in place<br />

<strong>Ambienta</strong> Architectural Systems © 17


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.8 Asian Cubicle Division Channel Fixing Detail<br />

1<br />

2<br />

3 4<br />

Asian Cubicle Division Channel is cut from set lengths on-site to suit, drilled and then fixed to the floor. The division is then positioned<br />

and fixed in place.<br />

1. Cut the Division Channel to length<br />

2. Mitre end parts with a 45 degree mitre where applicable<br />

3. Drill fixing holes in the Division Channel and floor (use suitable fixings supplied by others)<br />

4. Apply a mastic sealant to the internal face of the channel and position Asian division to suit<br />

5. Remove excess sealant<br />

<strong>Ambienta</strong> Architectural Systems © 18


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.9 Head Rail Fixing Detail<br />

1<br />

(x)<br />

2<br />

3 4 5<br />

Fix the Head Rail (<strong>HR1</strong>) onto all pilasters using the ‘V’ groove as the centre line when drilling. Always ensure that the cut face of the<br />

Head Rail is positioned against the wall or where 2 lengths meet. All joints must fall between the centre of the centre pilasters.<br />

1. Measure distance between wall panels, or between wall panel and return end division (x)<br />

2. Cut Head Rail (WC - 005) to required length<br />

3. Mark hole positions to drill on top face of Head Rail, ensure 2 no. fixing points per centre pilaster<br />

4. Drill 5 mm dia through holes (countersink 3 mm)<br />

5. Fit using Multi Purpose Screw (WC - 009)<br />

<strong>Ambienta</strong> Architectural Systems © 19


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.10 Door Hinge Fixing Details<br />

1<br />

2<br />

The Door Hinges are handed and are fixed to both the pilaster and door. The Door Hinges are supplied in packs of 3, please note that<br />

the top hinge is set to a 15 degree opening. Ensure care is taken when handling these and do not attempt to disassemble.<br />

1. Fit the top Door Hinge (WC - 006) to the Door. Use 2 no. Hinge Screws (WC - 011)<br />

2. Repeat for the remaining 2 no. hinges<br />

3. Fit the hinged door to the end / centre pilaster. Use 2 no. Hinge Screws (WC - 011) per hinge<br />

<strong>Ambienta</strong> Architectural Systems © 20


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.11 Cubicle Lock Fixing Detail<br />

1<br />

2 3<br />

4<br />

The Cubicle Lock (WC - 007) is made up of multiple components which allow you to fix from both sides of the door. Please note the<br />

red indicator must be lined up with the bolt locked position.<br />

1. Attached the indicator turning thread to the back base plate, align through the door with the front base plate, fix with screws<br />

2. Push the back and front cover plates into position<br />

3. Insert the indicator bolt into the back cover plate<br />

4. Use the grub screw to fit the indicator bolt into the required position<br />

<strong>Ambienta</strong> Architectural Systems © 21


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.12 Cubicle Indicator Keep Fixing Details<br />

1 2<br />

3<br />

Fixing the Indicator Keep into position within standard and ambulant cubicles.<br />

1. Mark position of indicator keep on the inside face of the pilaster<br />

2. Drill 2.5 mm dia hole 15 mm deep<br />

3. Use the Keep Fixing Screw (WC - 013) to fix the indicator bolt to the centre / end pilaster<br />

<strong>Ambienta</strong> Architectural Systems © 22


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>HR1</strong><br />

<strong>Installation</strong><br />

3.13 Complete Cubicle Module<br />

Example of a Cubicle Module IN-CORNERTypical In - Line Range of 2 Cubicle Unit Details. In<br />

- Line Cubicles integrated with the <strong>Ambienta</strong> Facade Wall Lining System.<br />

<strong>Ambienta</strong> Architectural Systems © 23


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong><br />

Support<br />

<strong>Ambienta</strong> Architectural Systems © 24


<strong>Restroom</strong> <strong>Compartments</strong> - <strong>Ambienta</strong> <strong>Phenolic</strong><br />

Support<br />

Contact Us<br />

Should you wish to discuss the care for your <strong>Ambienta</strong> <strong>Phenolic</strong> <strong>Restroom</strong> Compartment system further, or make an enquiry<br />

about a future project, be it a Wall Lining Solution and / or <strong>Restroom</strong> System, please contact <strong>Ambienta</strong> Architectural<br />

Systems for specialist assistance.<br />

<strong>Ambienta</strong> Architectural Systems<br />

2825 Commerce Parkway<br />

North Port, FL 33946<br />

USA<br />

Telephone<br />

Mobile:<br />

Email:<br />

(855) 966-3925<br />

(941) 544 2707<br />

pwest@ambientaglobal.com<br />

www.ambientausa.com<br />

<strong>Ambienta</strong> Architectural Systems © 25


<strong>Ambienta</strong> Architectural Systems<br />

Version #3<br />

03 / 2014