Removal and replacement of ADU modules<br />

9.5.9.2 Inserting a new X Elevation ZRM<br />

To insert a new X Elevation ZRM follow the instructions above in<br />

reverse order.<br />

9.5.9.3 Removing the Elevation ZRM<br />

Tools needed:<br />

• 4 x 150 mm Allen key<br />

(located inside the<br />

service door of the ADU)<br />

1. Open the service hatch by releasing the two latches.<br />

2. Switch off the power to the antenna on the service switch.<br />

3. Rotate the antenna pedestal so that the Elevation Drive Belt faces<br />

the service hatch.<br />

4. Rotate the antenna dish to top position.<br />

5. Press in and turn the elevation locking pin (only available from<br />

serial number TBD) to locked position.<br />

6. Disconnect the connector from the Elevation ZRM.<br />

Figure 9-85: Elevation ZRM, disconnect connector<br />

9-66 Chapter 9: <strong>Service</strong> & maintenance 98-133966-E2