F.4 Alternative grounding for<br />

aluminum hulls<br />

The following guidelines assume a two-wire, isolated<br />

grounding arrangement; that is no part of the circuit, in<br />

particular the battery negative, is connected to any ground<br />

potential or equipment.<br />

F.4.1<br />

Grounding the ACU<br />

The ACU should preferably be grounded with the short cable.<br />

Further, the ACU must be grounded at its grounding stud to<br />

ensure a proper grounding if the short ADU cable is<br />

disconnected.<br />

The ground connection must be established at a dedicated RF<br />

ground (either capacitively or electrically coupled).<br />

Important Remember to make the ADU ground connection at the<br />

same electrical ground potential as the ACU (see<br />

Grounding the ADU).<br />

The ACU provides galvanic isolation (as required) from its<br />

input power terminals to the chassis/grounding stud. This<br />

way the isolated grounding arrangement is maintained.<br />

Alternative grounding for aluminum hulls<br />

FFFF<br />

F.4.2<br />

Grounding the ADU<br />

If the mounting base of the ADU is electrically connected to<br />

the hull (or any other ground potential than the ACU), the<br />

ADU must be isolated at its mounting bolts by means of<br />

shoulder bushings and washers, see F.6.3. This is done in<br />

order to prevent DC currents flowing in the hull thus causing<br />

electrolytic corrosion.<br />

However, a ground connection must be established via one of<br />

the mounting bolts using a separate ground cable. The<br />

ground cable must be routed parallel and in close proximity<br />

to the shielded coax cable hence connecting the ADU to the<br />

ACU Grounding kit. A heavy gauge wire with tinned strands<br />

(min. 6 mm 2 ) can be used for this purpose.<br />

Grounding and RF<br />

98-133966-E2 Appendix F: Grounding and RF protection F-7