Medical devices for Sleep Diagnostics and Therapy<br />
Continuous<br />
<strong>No</strong>n-invasive<br />
Blood pressure recording*<br />
<strong>No</strong> disturbances from cuff inflation<br />
SOMNOwatch<br />
plus BP<br />
syst./diast. Blood pressure<br />
3-channel-ECG<br />
Peripheral finger pulse<br />
SpO 2<br />
Activity<br />
Body position<br />
Patient Marker<br />
mmHg<br />
120<br />
syst.<br />
Continuous blood pressure profile (beat to beat)<br />
TIB (night)<br />
max. Drop of BP [%]<br />
max. Night<br />
Ref. BD<br />
80<br />
diast.<br />
min. Night<br />
t<br />
One-time calibration by RR-measurement<br />
based on PTT (Pulse Transit Time)<br />
48h recording time<br />
*patent pending
24hr long-term blood pressure report<br />
Sleep Profile<br />
Body Pos<br />
Hf<br />
Activity<br />
Systolic<br />
Blood Pressure<br />
Diastolic<br />
Night<br />
Sleep Profile<br />
Body Pos<br />
Hf<br />
Activity<br />
Systolic<br />
Blood Pressure<br />
Diastolic<br />
2<br />
3<br />
1<br />
Day/Night Report<br />
1 BP-reference<br />
2 BP-decrease<br />
3<br />
average nocturnal BP
Detection of Dipper / <strong>No</strong>n-Dipper<br />
Dipper<br />
<strong>No</strong>n-Dipper<br />
syst.<br />
BP<br />
syst.<br />
BP<br />
Analysis of clinically relevant<br />
Blood-Pressure-Fluctuations<br />
Advantages of PTT-method<br />
Sleep:<br />
Undisturbed recording<br />
<strong>No</strong> arousal reactions<br />
through blood-pressure-cuff<br />
Continuous blood pressure recording for<br />
accurate determination of max./min. values<br />
Determination of temporary increases of blood<br />
pressure as a measurement for nocturnal stress-factor<br />
Day:<br />
Secure interpretation of blood-pressure-fluctuations<br />
by recording the motoric activity<br />
Correction of the hydro-static pressure-components<br />
by additional recording of body position
Sleep/Wake Report based on Actigraphy<br />
Sleep Profile<br />
Activity<br />
Oximetry Report<br />
SOMNOwatch is a registered Trademark of SOMNOmedics<br />
SpO 2<br />
Hf<br />
ECG Report<br />
- Detection of Arrhythmia<br />
- Detection of Brady-/Tachycardia<br />
Sympatho-vagal Balance (SVB)<br />
Allocation of heart frequency<br />
Printed: July 2009 Rev.1 Subject to Change (without notice)! 2009 SOMNOmedics GmbH<br />
C<br />
Sympathikus<br />
HRV<br />
Vagus<br />
SVB<br />
SOMNOmedics GmbH - Am Sonnenstuhl 63 - D-97236 Randersacker<br />
Tel.+49(0)931/3590940-Fax+49(0)931/35909449<br />
E-Mail info@somnomedics.de<br />
Internet www.somnomedics.eu