Sun StorEdge SRC/P Intelligent SCSI RAID ControllerTM System ...
Sun StorEdge SRC/P Intelligent SCSI RAID ControllerTM System ...
Sun StorEdge SRC/P Intelligent SCSI RAID ControllerTM System ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Features Dual Ultra<strong>SCSI</strong> +<br />
<strong>Sun</strong> <strong>StorEdge</strong><br />
MultiPack<br />
Max. storage capacity per <strong>Sun</strong><br />
Enterprise 250 server<br />
<strong>RAID</strong>-0 performance (6 drive<br />
stripes, 12 drives total)<br />
864 GB 1.3 TB 1.2 TB 1.0 TB<br />
• 64-KB seq. read (MB/sec.) — — — —<br />
• 64-KB seq. read (MB/sec.) — — — —<br />
<strong>RAID</strong>-5 performance (6 drive<br />
stripes, 12 drives total)<br />
• 2-KB random read (IOPS) — — — —<br />
• 2-KB random read (IOPS) — — — —<br />
• Support for system boot disk Yes TBD No No<br />
• On-board microprocessor<br />
handles all disk I/O and <strong>RAID</strong><br />
calculations<br />
No Yes Yes No<br />
• ECC and battery protected I/O<br />
data cache memory<br />
No Yes, 64 MB Yes, 16-MB<br />
upgradeable to<br />
64 MB<br />
• On-board battery backup N/A Standard Standard N/A<br />
– # hours of cache data<br />
protection<br />
48 hours 72 hours<br />
– Battery monitor with<br />
battery-low/battery-fail<br />
indicator<br />
Yes<br />
– On-board battery charger Yes<br />
– Batteries recharge time,<br />
max.<br />
3 hours<br />
Key to notations below:<br />
S = <strong>Sun</strong> <strong>StorEdge</strong> <strong>SRC</strong>/P Storage Manager<br />
V = VERITAS Volume Manager<br />
R = <strong>RAID</strong> Manager<br />
D = Solstice DiskSuite<br />
• Supported <strong>RAID</strong> managers • V or D • S or • R or<br />
• V<br />
– <strong>Sun</strong> <strong>StorEdge</strong> <strong>SRC</strong>/P<br />
Storage Manager (S)<br />
S + V or D R + V or D<br />
– <strong>RAID</strong> Manager (R)<br />
– VERITAS Volume Manager<br />
(V)<br />
– Solstice DiskSuite (D)<br />
• Supports <strong>RAID</strong> 0, 1, 1+0, 5<br />
• Supports <strong>RAID</strong> 3<br />
• Supports <strong>RAID</strong> 5+0<br />
• Supports multi-modes<br />
(different <strong>RAID</strong> levels for<br />
different drives)<br />
• V, D<br />
• No<br />
• No<br />
• V, D<br />
<strong>Sun</strong> <strong>StorEdge</strong><br />
<strong>SRC</strong>/P<br />
Controller<br />
• S, V, D<br />
• No<br />
• S<br />
• S, V, D<br />
<strong>Sun</strong> <strong>StorEdge</strong><br />
A1000 Array<br />
• R, V, D<br />
• No<br />
• No<br />
• R, V, D<br />
<strong>Sun</strong> <strong>StorEdge</strong><br />
A5000 Array<br />
Just the Facts December 1999<br />
No<br />
• V<br />
• No<br />
• No<br />
• V<br />
Positioning