Features Dual Ultra<strong>SCSI</strong> +<br />

<strong>Sun</strong> <strong>StorEdge</strong><br />

MultiPack<br />

Max. storage capacity per <strong>Sun</strong><br />

Enterprise 250 server<br />

<strong>RAID</strong>-0 performance (6 drive<br />

stripes, 12 drives total)<br />

864 GB 1.3 TB 1.2 TB 1.0 TB<br />

• 64-KB seq. read (MB/sec.) — — — —<br />

• 64-KB seq. read (MB/sec.) — — — —<br />

<strong>RAID</strong>-5 performance (6 drive<br />

stripes, 12 drives total)<br />

• 2-KB random read (IOPS) — — — —<br />

• 2-KB random read (IOPS) — — — —<br />

• Support for system boot disk Yes TBD No No<br />

• On-board microprocessor<br />

handles all disk I/O and <strong>RAID</strong><br />

calculations<br />

No Yes Yes No<br />

• ECC and battery protected I/O<br />

data cache memory<br />

No Yes, 64 MB Yes, 16-MB<br />

upgradeable to<br />

64 MB<br />

• On-board battery backup N/A Standard Standard N/A<br />

– # hours of cache data<br />

protection<br />

48 hours 72 hours<br />

– Battery monitor with<br />

battery-low/battery-fail<br />

indicator<br />

Yes<br />

– On-board battery charger Yes<br />

– Batteries recharge time,<br />

max.<br />

3 hours<br />

Key to notations below:<br />

S = <strong>Sun</strong> <strong>StorEdge</strong> <strong>SRC</strong>/P Storage Manager<br />

V = VERITAS Volume Manager<br />

R = <strong>RAID</strong> Manager<br />

D = Solstice DiskSuite<br />

• Supported <strong>RAID</strong> managers • V or D • S or • R or<br />

• V<br />

– <strong>Sun</strong> <strong>StorEdge</strong> <strong>SRC</strong>/P<br />

Storage Manager (S)<br />

S + V or D R + V or D<br />

– <strong>RAID</strong> Manager (R)<br />

– VERITAS Volume Manager<br />

(V)<br />

– Solstice DiskSuite (D)<br />

• Supports <strong>RAID</strong> 0, 1, 1+0, 5<br />

• Supports <strong>RAID</strong> 3<br />

• Supports <strong>RAID</strong> 5+0<br />

• Supports multi-modes<br />

(different <strong>RAID</strong> levels for<br />

different drives)<br />

• V, D<br />

• No<br />

• No<br />

• V, D<br />

<strong>Sun</strong> <strong>StorEdge</strong><br />

<strong>SRC</strong>/P<br />

Controller<br />

• S, V, D<br />

• No<br />

• S<br />

• S, V, D<br />

<strong>Sun</strong> <strong>StorEdge</strong><br />

A1000 Array<br />

• R, V, D<br />

• No<br />

• No<br />

• R, V, D<br />

<strong>Sun</strong> <strong>StorEdge</strong><br />

A5000 Array<br />

Just the Facts December 1999<br />

No<br />

• V<br />

• No<br />

• No<br />

• V<br />

Positioning