<strong>System</strong> environment A basics<br />

<strong>System</strong> <strong>description</strong><br />

Installing within the control cabinet<br />

1.1<br />

<strong>System</strong> Installing PSSu ][Einbau Zusammengestellte environment <strong>description</strong> in within Schaltschrank the control A basics Sys Texte<br />

cabinet A + B<br />

A PSSu system must be installed in a<br />

control cabinet. Use a zinc-plated<br />

DIN-rail in accordance with DIN EN<br />

50022 as the mounting rail (top hat<br />

rail). Dimensions:<br />

35 x 7.5 mm or 35 x 15 mm<br />

When installing, please note the<br />

following:<br />

Where vibration and shock stress<br />

place increased requirements on<br />

the system fastenings, we recommend<br />

that the mounting rail is<br />

screwed to the mounting plate approximately<br />

every 200 mm.<br />

We recommend that it is installed<br />

horizontally on a vertical wall. If other<br />

mounting positions are used (e.g.<br />

vertical installation), please take the<br />

following into account:<br />

– Optimum upward heat dissipation<br />

can no longer be guaranteed:<br />

The ambient temperature<br />

is restricted (see technical details<br />

for the modules).<br />

– Vibration and shock stress place<br />

higher requirements on the system<br />

fastenings: use additional<br />

metallic end brackets!<br />

We recommend you leave a distance<br />

of 20 mm from the control<br />

cabinet wall to enable you to exchange<br />

modules.<br />

The coated versions of the PSSu modules<br />

are suitable for use where there<br />

are increased environmental requirements<br />

on temperature and humidity.<br />

Please refer to the technical details.<br />

On the coated version of some output<br />

modules, please also note the derating<br />

at higher temperatures.<br />

Mounting distances<br />

][Montageabstaende Sys A + B<br />

The values shown in the diagram for<br />

mounting distances are minimum<br />

specifications.<br />

The ambient temperature of the PSSu<br />

system in the control cabinet must not<br />

exceed the figure stated in the technical<br />

details for the modules, otherwise<br />

air conditioning will be required.<br />

1.1<br />

Mounting distances<br />

35 mm<br />

(1.378")<br />

Head Module<br />

20 mm 20 mm<br />

(0.787") (0.787")<br />

35 mm<br />

(1.378")<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

2011-04<br />

1.1-21