Modules<br />

Link modules<br />

PSSu XB F-T<br />

3.12 PSSu-2011-01<br />

Modules Link Gertebild modules<br />

XB F-T<br />

][Bildunterschrift XB<br />

Base station for attaching a connection<br />

cable for PSSuniversal<br />

Approvals<br />

Module features<br />

][Merkmale XB<br />

The module terminates a PSSu system<br />

and extends the module bus<br />

via a cable connection.<br />

The module supports a remote station<br />

PSSu XR F-T.<br />

Plug for the module bus connection<br />

cable<br />

The cable connection transfers:<br />

– FS data<br />

– ST data<br />

– Module supply<br />

][Merkmale_Versorgung PD<br />

The module routes the periphery<br />

supply from the module bus to the<br />

base module terminals.<br />

][Merkmale_LED PD<br />

LED for:<br />

– Periphery supply<br />

][Merkmale_Zusatz ST/FS-Module Sys A<br />

For standard and failsafe applications<br />

in system environment A<br />

from the connections, but may not be<br />

fed through that route.<br />

][Gertebeschreibung ST/FS-Module Sys A<br />

The module may be used for standard<br />

and failsafe applications in system environment<br />

A.<br />

PSSu XB F-T<br />

Module <strong>description</strong><br />

SÜDDEUTSCHLAND<br />

<br />

<br />

<br />

][Gertebeschreibung XB<br />

The module may be used as a base<br />

station to extend the PSSuniversal<br />

module bus inside a control cabinet<br />

via a cable connection. It can be operated<br />

with a remote station of type<br />

PSSu XR F-T plus the connection cable<br />

PSSu A RJ45-CAB 1.5M.<br />

][Gertebeschreibung PD<br />

The module may be used for additional<br />

connections to the periphery supply.<br />

The periphery supply can be drawn<br />

Zulassungen<br />

Block diagram<br />

Blockschaltbild<br />

14 24<br />

11 21<br />

12 22<br />

RJ45<br />

3.12<br />

Module Bus<br />

Periphery<br />

Supply<br />

+ 24 V DC<br />

Module<br />

Supply<br />

+ 5 V DC<br />

24 V 0 V<br />

Periphery<br />

Supply<br />

Interface<br />

Data<br />

(FS/ST)<br />

C-Rail<br />

13 23<br />

3.12-16<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

PSSu-2011-01