<strong>Swipe</strong>-N-<strong>Clean</strong> Operating Manual<br />

BAY AND VACUUM PBC ADDRESS PROGRAMS<br />

Bay:<br />

Remove 24vac power connector from top left corner of the PBC board.<br />

Press and hold the [0] zero on the keypad, then reconnect the 24vac power connector to the board and then release<br />

the [0] zero.<br />

Check the board to ensure the MS light next to the keypad input connector is on.<br />

a. The [8] eight key on the keypad will cycle the four light until you have the desired position.<br />

When the MS light is the only light on, of the four function lights, press the [5] five on the keypad to proceed to the<br />

settings for the timer address.<br />

Check the lights between the two ten position connectors at the top of the board to ensure that SOL 8 is on and<br />

then:<br />

a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the bay<br />

you are addressing.<br />

b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />

c. When the desired solenoids are on press the [5] five key.<br />

Check the lights between the two ten position connectors at the top of the board to ensure that SOL 9 is on and<br />

then:<br />

a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the bay<br />

you are addressing.<br />

b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />

c. When the desired solenoids are on press the [5] five key.<br />

Check to see if the MS light is now on. If not press the [5] five key until MS is the only light on; then press and<br />

hold the [1] one key until the horn sounds.<br />

Vacuum:<br />

Turn off 24vac power circuit breaker in the top left corner of the vacuum meter hull.<br />

Press and hold the [0] zero on the keypad, then re-energize the 24vac power circuit breaker then release the [0]<br />

zero.<br />

Check the board to ensure the Aux1orAux2 light at the top left of the PBC board is on.<br />

a. The [8] eight key on the keypad will cycle the four light until you have the desired position.<br />

When the correct auxiliary light is on press the [5] five on the keypad to proceed to the settings for the timer<br />

address.<br />

Check the lights at the top left corner of the board to ensure that SOL 8 is on and then:<br />

a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the<br />

vacuum you are addressing.<br />

b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />

d. When the desired solenoids are on press the [5] five key.<br />

Check the lights at the top left corner of the board to ensure that SOL 9 is on and then:<br />

V-<br />

10<br />

a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the bay<br />

you are addressing.<br />

b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />

c. When the desired solenoids are on press the [5] five key.<br />

. . . . . . . . . . PROGRAMMING INSTRUCTIONS