Swipe-N-Clean 1.0 Complete - Jim Coleman Company
Swipe-N-Clean 1.0 Complete - Jim Coleman Company
Swipe-N-Clean 1.0 Complete - Jim Coleman Company
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Swipe</strong>-N-<strong>Clean</strong> Operating Manual<br />
BAY AND VACUUM PBC ADDRESS PROGRAMS<br />
Bay:<br />
Remove 24vac power connector from top left corner of the PBC board.<br />
Press and hold the [0] zero on the keypad, then reconnect the 24vac power connector to the board and then release<br />
the [0] zero.<br />
Check the board to ensure the MS light next to the keypad input connector is on.<br />
a. The [8] eight key on the keypad will cycle the four light until you have the desired position.<br />
When the MS light is the only light on, of the four function lights, press the [5] five on the keypad to proceed to the<br />
settings for the timer address.<br />
Check the lights between the two ten position connectors at the top of the board to ensure that SOL 8 is on and<br />
then:<br />
a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the bay<br />
you are addressing.<br />
b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />
c. When the desired solenoids are on press the [5] five key.<br />
Check the lights between the two ten position connectors at the top of the board to ensure that SOL 9 is on and<br />
then:<br />
a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the bay<br />
you are addressing.<br />
b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />
c. When the desired solenoids are on press the [5] five key.<br />
Check to see if the MS light is now on. If not press the [5] five key until MS is the only light on; then press and<br />
hold the [1] one key until the horn sounds.<br />
Vacuum:<br />
Turn off 24vac power circuit breaker in the top left corner of the vacuum meter hull.<br />
Press and hold the [0] zero on the keypad, then re-energize the 24vac power circuit breaker then release the [0]<br />
zero.<br />
Check the board to ensure the Aux1orAux2 light at the top left of the PBC board is on.<br />
a. The [8] eight key on the keypad will cycle the four light until you have the desired position.<br />
When the correct auxiliary light is on press the [5] five on the keypad to proceed to the settings for the timer<br />
address.<br />
Check the lights at the top left corner of the board to ensure that SOL 8 is on and then:<br />
a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the<br />
vacuum you are addressing.<br />
b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />
d. When the desired solenoids are on press the [5] five key.<br />
Check the lights at the top left corner of the board to ensure that SOL 9 is on and then:<br />
V-<br />
10<br />
a. Use the address chart in the <strong>Swipe</strong> N <strong>Clean</strong> manual to determine which lights should be on for the bay<br />
you are addressing.<br />
b. Use the keypad programming key to determine which key to press to toggle the wanted solenoids.<br />
c. When the desired solenoids are on press the [5] five key.<br />
. . . . . . . . . . PROGRAMMING INSTRUCTIONS